Loading...
HomeMy WebLinkAboutBuilding 02-1137 :;- 0 0 ~ 0 0"I5J 0 0 0 0 "tl 0 ,. -0 C/J :x: ~ c Z_ "0 0 0 ~ 0 en"TIz"TI"TI"TI 0 C ~~ (l) Z 8 0 n- o 0 0 3: =izen~Oo Z m :::0 mo ,. 0 ;:0 ;:0 ;:0 3: ~>c:!C~S m :::0 m O"TI t::::l r :-! ;:0 ;:0 ;:J\ zrs;:zcz z en =!"tl t'!l rn rn m en r 0 0 en ~ =!G')~G') 9 0:::0 :>a t ~/ -I > Z z- t'!l ~ > -I -4 m 0 - zO to ..... ijj en o~ 0 S cD 0 "TI -I Z 0;:0 co ;:0 -I > -'=' =!~ :>a <n r (5 0 ~i ~ C) Z -I O;:J\ "TI 0 > 0 mrn ~ 0 > Z ;:0 ~ :::0 - r 0 ::< ~ ~ r -I "TI "tl "tl r= ~ :x: 0 ;:0 ;:0 :>a m ~i 0 0 000000 t'!l Z 0 0 ~ m rn rn :!C"tlen::i::!C"tl X rn m rnrm>rnr ~ :>a -I 0 0 oC:~-IoC: ~ Z :x::!C rn:x::!C "tl 0 en cs en ~ ~ "TI~;:O;:O;:o~ m 0 ~ 0 ~ ~ "tl ::l 0 -Z:x::t-Z :::0 z :x: ::! m (l) -I ~G')oo G') :!C -I m ::l.. ~ 0 (') (5 r"TIOO ;:0 =i ~ C -I 0 Z -;:J\A - Z c: 6 ~ tD Zc:c: r ~"tl"tl 9 m Z rn C 0 "TI ~ N 0 .,.. :x: :::0 m ~ 0 0 c 0 N ~ ~ :::0 < 000000 en rn I :i! z ;:0 G')"TI"TIorn 0 Z '"'" ,. >;o;oo~ -1 Ro ,. G') ~mm:!CG') W m c ~ < _"tl"tl"tl~ ;;J > ~s:s:s:o r..j z >ooz:;; ""! 0 _rnm-l_ ~ ~ !T' :::O"TI;:O r -1 -1-_ r i enz z m -I~ G') Date Rec' d CITY OF PRIOR LAKE BUILDING PERMIT, TEMPORARY CERTIFICATE OF ZONING COMPLIANCE AND UTILITY CONNECTION PERMIT ~ic(2. tl/1fer /{J. 5 W- LEGAL DESCRIPTION (office use only) LOT BLOCK ADDITION p/ ~;}~ 1_ White File 2 Pink City 3. Yellow Applicant PERMIT NO. Ol/( (31 ZONING (office use) '}( 15n PID 3/'tJOb- I OWNER (Name) JoIU1 l (3 a..lfu1h~ lAIIYt gtMd ~ qz. 'jjtfe1';tJ J vv- (Address) ((DiUtv' CoIlJnui Dll M \ POUt-, /LtJ j SrNV-- BUILDER (Name) (Contact Name) (Address) (Phone) '/'-Iv "-410 Z- ~LL. qSl -io7~ U)(;, "/ X IS! e12-, ----4<{O -3iGf (Phone) (Phone) TYPE OF WORK o New Construction ODeck '~orch ORe-Roofing ORe-Siding OLower Level Finish o Fireplace o Addition o Alteration OUtility Connection o Mise. PROJECT COST IV ALUE (excluding land) $ Zl(-OO~cJU " I hereby certify that I have furnished information on this application which is to the best of my knowledge true and correct I also certify that I am the owner or authorized agent for the above-mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with submitted plans, I am aware that the building official can revoke this permit for just cause. Furthermore, I hereby agree that the city official or a designee may enter upon ~to perform needed inspections. b{' d- ~~~.-J S>i"') X . Itz/tll ;Zf,~t#c;L- ~ ~,J (/ Sigllature Contractor's License No. Date Permit Valuation L4000. - Permit Fee $ 3(1. Z.S Plan Check Fee $ UfS. 'l-I State Surcharge $ f2..- Penalty $ Plumbing Permit Fee $ Mechanical Permit Fee $ Sewer & Water Permit Fee $ Gas Fireplace Permit Fee $ Park Support Fee # $ SAC # $ Water Meter Size 5/8"; 1 "; $ Pressure Reducer $ City SAC and WAC # $ Water Tower Fee # $ Builder's Deposit $ Other $ TOTAL DUE ~ tf...,/f-07- $ if3 LI, t/-&;" I ~~:. ~;foJ~ I ~~ceiPt NUrJ03~ This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and may proceed as requested. This document when signed by the City Planner constitutes a temporary Certificate of Zoning compliance and allows construction to commence. Before occupancy, a Certificate of Occupancy must be issued, " &;:7 . Of I\O~ Date Special Conditions, if any 24 hour notice for all inspections (952) 447-9850, fax (952) 447-4245 16200 Eagle Creek Avenue Prior Lake, MN 55372 White - Building Canary - Engineering Pink - Planning The ("('nler or the tlkt Counlr)' BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT APPLICATION RECEIVED ,r'- , ;' .-.". The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: ,'-) ,,_.,'~ Accepted / Accepted With Corrections Denied 0( I / . OIJ- ~ UJ C{)- (I VfJ 4~/"-"/~ Reviewed By: ~ LA I ~ Date: Comments: "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." L White - Building Canary - Engineering Pink - Planning Thr ("("nlff of lhr Lab Countr)' BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT 7 ernCf? V C~)/US+'r- APPLICATION RECEIVED f- J.d---"-();?-- The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: ~S-q ~ - ft;~ kld Accepted Accepted With Corrections Denied Reviewed By: Date: Comments: "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction, Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." 09/19/2002 14:26 FAX 4521826 INSTANT TESTING/ALLIED IgJ UUl. IT= =CO INSTANT TESTING COMPANY 4000 BEAU D'RUE DR lYE . EAGAN. MN 55122 PHONE: (612) 4.s4.~544 . FAX: (612) 452-1826 September 19, 2002 Roncor Construction 10740 Lyndale Avenue South Bloomington, Minnesota 55420 RE: Inspection - 2892 Center Road Southwest Prior Lake, Minnesota Per your request, a site visit was conducted on September 18, 2002 to evaluate subqrade soils for the construction of a porch and deck addition to an existing single family residence. Located at the rear northeast section of the residence, 1 cores had been placed for Sono-tube installation and pier construction. Three of the piers will provide support for the increased loads of the four season porch. Soils extracted from the approx. 44 inch deep core holes, indicted a dark organic clay loam, most likely landscape fill soils- A handauger probe conducted at the base of the center core hole indicated medium soft organic soils and wetland vegetation to a depth of approx. 4 1/2 feet. Underlying soil consisted of a moist, grey clay and trace granular with acceptable loadbearing capacity. Although a elevated level of soil moisture was apparent, no ground water migration was observed. It is recommended that the porch pier excavations be increased in depth approx. 4 1/2 feet to achieve competent soils. At the contractors option, a full depth pier may be poured, or backfilled ~ith a free draining granular to provide a min. 48 inch frost footing depth. In our opinion, with the noted recommendations, the observed subgrade soils are acceptable for construction. Sincerely, Insta . esting' Charge codes: #70 - 1 / #605 - 1 1/2 hour / 1612 - 42 Miles cc: Paul - City f Prior Lake Building Inspections 0~!05!2002 09:35 9528959259 BOHLEN SURV AND ENGR PAGE 02 - " - l.r....~= =:rrr~~~Ut:."" UNGIi ... M l.lIoII5 . .... "Atl&i ~ ....,~C3L e~~ - __ ...- 1II!l"''IGI ,.~.. 10"" CITY OF PRIOR. LAKE Impervious Surface CalculatiollS CT- he S.a.bnaillCd -idl .uMInI .....it Appllc:lliall.) For All Pro~erties Located in the Shoreland Dimi'a (SO). The Maximum Impervious Surface Coverage Permitted in 30 Perceat. Property Address 1.q,~ 2.. te.~e(' ~OG.~ , , Lot Area 3~O.. 1( = %.~S""OO Sq. Feet X 30% - .............. 7"'~O , ~ ,. "tJ~d ~....*.......*............~..................~..*....................... HOUSE LElIlGTH 10. Wttmi x~- :l: .. SQ. FEET \tOO ;..TIACHED GARAGE 2.cfAX 2.3" .. ~"" TOT At. PRINCIPLE STRUCI'tlRE-.-.---.-.. ",,' ~ "0 ~ F DETACHED BLDGS ~~.~ (~Shed) /2.' x x IQ" rlorO TOTAL DETACHED 'lTD.DINGS...._._..._...... ''2.0 c;F ~wk ,,' lil \oIlt, s ~2. "f uwliC. ~~.. '10 ~ eo DIUVEWAYIPA~I)ARE.ASPwJ' 2.~.f x 1i-" ..' 1,00 (v. ..- . "~c. "~../ ~.. x l' .s ~",1. (SW!l:w.zWParkins ~) ~.. x I ~~ - S" fj ,I ". \]" '11 T01,u, P A YED AREAS.--..-- . ....-..---.-. 1.0 ,0 9Ro~oSE.D IpAnOSIPO~CHESIDECKS \ (Cpc:II ~ ~- lIIilL opllftillJ ~CO'I IaaUllL .ilft & pc:"Iious surka 1Mla*. ~ lUIt calbidl!\'!ll JO be i.,.,.;aus) 21t/ ~ 'to' x - ~z.o ~ - x - TOT AI. DECKS......--..-......-..-......-....-..---.. !"'1..0 x )[ :5 OTHER. - TOT AI. OT"B:E:.R---....-----.....---......--...----..- TOTAL IMPERVIOUS SURFACE ... L \ "'''.~e..~ porc.."N.& tJNDD.A0\O' 1 '5'"0" ~ 110 , Prepared By la"'l\ ~ \~~o..{~ } ~.E. Date Company' ~() ~ \.e~ ~u..i' "e~ ~ 1\~ ~ E.~~~~\;_rhone # 4;10 ] T;.\ 1- ; '3~ 0 ' J .....&Qf e.. ~.. 01- ~S"~ Qq, 't2.(2- PRIOR LAKE INSPECTION RECORD DEPARTMENT OF BUILDING AND INSPECTION SITE ADDRESS /ifiz. ce~~ 'P-o NATURE OF WORK "Pdk.-l-\ i ~(C USE OF BUILDING 12&-:; A/~ . PERMIT NO. ClZ ~/13/ DATE ISSUED CONTRACTOR -FoN t'J1>(L PHONE ~ Sz... 8e1"~ NOTE: THIS IS NOT A PERMIT FOR ANY OF THE INSPECTIONS BELOW THE PERMIT IS BY SEPARATE DOCUMENT I (fao" I I PLACE NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED ROUGH - INS DATE I FOOTING CJ~ ~ '02.. COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED I I FINALS rI -lJ~02- BUILDING ELECTRICAL ~ DO NOT OCCUpy UNTIL ABOVE HAS BEEN SIGNED NOTICE This card must be posted near an electrical service cabinet prior to rough-in inspections and maintained until all inspections have been approved. On buildings and additions where no service cabinet is available, card shall be placed near main entrance. Call between 8:00 and 9:00 A.M. for all inspections FOR ALL INSPECTIONS (952) 447-9850