HomeMy WebLinkAboutFire Alarm Insp. 3/6/2008 ~ ~ -~ ------- --- -- ----- -...... .... Metro Alarm "We Save Lives & Protect Property" P.O. BOX 1775 . BURNSVILLE, MN 55337 . SERVICE (952) 890-6684 · FAX (952) 707-6881 · L1C#TS00401 Iii:\ www.metroalarmco.com / ~ Underwriters Laboratories Inc. @ ALARM SERVICE #S8526-1 FIRE ALARM INSPECTION AND TEST REPORT I COpy TO: CLIENT _FIRE DEPT. I ACcr. NO 1,.' ~ 1- J /ll 3- SERVICE CALL NO. LI LJ ~ tJ/{ U.L. CERTIFICATE NO. . I DATE 1 //.. ~~ CUSTOMER r ,., re t;J r a. T4! J~ r~....... CONTACT M,1<.e M 4" \..JP. J I TITLE ADDRESS '-I ~ q ()' CdJ"'rr~rJ " <;1 5f. PHONE '152. 41.} 7- ZJ 7 Z BI-MONTHLY _SEMI-ANNUAL CITY PrinT Laic"" STATE M All ZIP C;b' 377- MONTHLY )lANNUAL QUARTERLY FINAL CONTROL PANEL MANuFAcruREIJ,clnb#,l!Ihh MODEL NO. 6 _c:;qOO LOCATION Ra ~ e IYI #1 ~ f I. t/J.Jv .--""" - TYPE OF SIGNALlNG , I POWER IJ~IR. BRKR. LOCATION I NO.; ~ LOCKED CIR BRKR. DEDICATED CIR "GENERAL ALARM _SELECTIVE SIGNALS _CODED _PRE-SIGNAL SOURCE ~.....j <).:;1r~ p.,,,p ) _YES ~O )eYES - NO BATTERIES VOLTWlTHCH~R.. N TROUBLE RESPONSE TO ZONE TROUBLE SIGNAL TROUBLE ACIOP POWER LOSS EARTH GROUND VOLT WITHOUT IA"GER 7 1 ~ 1 . ~EW CONDITIONS )(NORMAL NOTE )U'ORMAL NOTE ~ORMAL NOTE NORMAL NOTE COMMUNICATOR MANUFACTURE 5 fi M E ~EL NO. LOCATION ~ -A M P A'J BATTERIES VOLT WITH CHARGE7 ' NOTE # POWER CI~. BRKR. LOYIO~ NO. LOCKED CIR BRKR. DEDICATED CIR VOLT WITHOUT COOGER NEW SOURCE YES NO YES NO CENTRAL MONITORING RESPONSE TO ALARM TROUBLE RESPONSE TO ZONE TROUBLE SIGNAL TROUBLE ACIOP POWER LOSS EARTH GROUND STATION P.ORM. NOTE # CONDITIONS ~NORMAL NOTE lO'IORMAL NOTE .kNORMAL NOTE NORMAL NOTE COMMUNICATOR PRIMARY # <1SZ'" Lftf7- <t3~2 COMMUNICATOR SECONDARY # Cf S 2 - Lj'17 - t. 0 J 7 AUXILIARY FUNCTIONS ANNUNCn~~R f'nFG) i I MODEL TYPTO _IN CAD _GRAPHIC CRT) I VOLTAGE I NO OF ZONES I UNUSED PTS. (. DClra 17. LED DROP iLCD J '{ v D [. ELEVATOR (f REtALL TO PRIMARY FLOOR RECALL TO ALTERNATE FLOOR ELEVATOR RESTART FIRE RECALL _NORMAL _ NOTE - N/A NORMAL NOTE N/A FROM FIRE SUe. AUTOMATICALLY YES NO SPRINKLER SYSTEM: METRO ALARM'S INSPECTION ONLY INCLUDES A FUNCTIONAL TEST. ACTUAL FIRE SPRINKLER TEST WAS DONE BY: TESTED: PERIPHERAL FUNCTION TEST DEVICE L I r1.c~~ FLOOR VOLTS MFG & MODEL # NOTE Manual Stations Z 4 I 6l/7 Ei""u1A R 01 R Reat DeIecton I '0 I t" ~P..fFb..~< Fixed Heat Detectors . Photo Smoke 1 ~ 3 12 V' {){ E5Lhnlf''x Ion Smoke Duct Smoke , Waterllow GVT PIV Low Air Horns Only Strobes Only Horn I Strobes L S I 2IJ..,h/ 6~,.. lex ~- V' III Speaker I Strobes Door Holders I Z till VI F,./ ~ J< NOTATIONS AND COMMENTS ~ . /1/ J Te&;/ z!' d r;, /J J , .. A ~ ~/7 ./" ./ CUSTOMER SIGNATURE: SERVnB.Ep ~~/.vnJmIT. - /fI/f/;- /7 // /7. . ~;Z;~ ,/ / .' ~- II v