HomeMy WebLinkAboutFire Protection 5/6/2008 SUMMIT FIRE PROTECTION 575 MINNEHAHA AVE. W" ST. PAUL, MN 55103. (651) 251-1880 3026 40TH AVE. NW. ROCHESTER, MN 55901. (507) 280-0622 418 GREAT OAK DR., WAITE PARK, MN 56387 . (320) 257-6390 760 LIBERTY WAY, NORTH LIBERTY, IA 52317 . (319) 665-4330 4208 ENTERPRISE CIRCLE. DULUTH, MN 55811. (218) 740-4412 SHEET I OF 2 - Use separate sheet for each building inspection REPORT OF INSPECTION MINNESOTA LICENSE NO. C007S INSPECTION NAME (-; STREET I /( /"-. JOB NUMBER BUILDINGILOCATION >" INSPECTOR CITY & STATE r' { ,/" DATE (.. Owner's Section (to be answered by Owner or Occupant) A. Explain any occupancy hazard changes since the previous inspection: B. Describe fire protection modifications made since last inspection: 1h . ~ 2Lo 115 -$u {J () 32;2..13~ ~ \50 C. Describe any fires since last inspection: D. When was the system piping last checked for stoppage, corrosion of foreign material? E. When was the dry-piping system last checked for proper pitch? F. Are dry valves adequately protected from freezing? Signature Title Date Inspector's Section (All n~sponses reference current inspection) NA =NOT APPLICABLE 1. General a. Is the building occupied? i21.Yes D No b. Are all systems in service? ClYes D No c. Is there a minimum of 18 in. (457 mm) clearance between the top of the storage and the sprinkler deflectors? DYes ANo d. Does all electrical heat tape appear to be satisfactory? DYes D NoCilNA e. Does the hand hose or standpipe on the sprinkler system(s) appear to be satisfactory? DYes D No D\NA 2. Control Valves (See Item 15.) a. Are all sprinkler system control valves and all other valves in the appropriate open or .closed position? DYes D No b. Are all control valves in the open position locked, sealed or equipped with a tamper switch? DYes 0 No 3. Tanks, Pumps, Fire Department Connections a. When was fire pump last tested for performance? b. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? DYes D No CtNA c. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight? Q-Ves D No D NA Are they accessible and visible? i:lYes 0 No D NA 4. Wet Systems a. Are cold weather valves (O.S. & Y) in the appropriate open or closed position? DYes D No CtNA b. Have antifreeze system solutioIJs j;een tested? DYes 0 No [;} NA c. What temp is antifreeze? /l./' d. In areas protected by wet system(s), does the building appear to be properly heated in all areas, including blind attics and perimeter areas where accessible? QYes 0 No D NA 5. Dry System (See Items Il to 13) a. Are dry valve(s) in service? DYes 0 No 0 NA b. Are the air pressures and priming wat:e'r levels in accordance with the manufacturer's instructions? DYes 0 No 0 NA c. Has the operation of the air.4r ni~ogen supplies been tested? DYes D No DNA Are they in service? DYes D No DNA d. Were low points drained duringtl)is inspection? DYes D No D NA How many? e. Did quick-opening devisi'\' operate satisfactorily? DYes D No DNA f. Did the dry valve(s) trip pr1Jperly during the trip pressure test? DYes D No D NA g. Did the heating equipment in the dry-pipe valve room(s) operate at time of inspection? DYes 0 No 0 NA 6. Special Systems (See Item 14.) a. Did the deluge or pre-action valves oper<lteproperly during testing? DYes D No D NA b. Did the heat-responsIVe devices op~ate p~perly during testing? DYes D No DNA c. Did supervisory devices operateliuriJIg }es'fing? DYes D No D NA d. Did flow for kitchen hood system shut off gas or electric? DYes D No D NA 7. Alarms a. Did water motor(s) and gong(s) test satisfastorily? DYes D No aNA b. Did electric alarm(s) test satisfactorily? jJYes D No D NA C '" c. Did supervisory alarm service test satisfactorily') CtYes 0 No 0 NA _::'f d. Did tamper switches test satisfactorily? r:)Yes DNo D NA 8. Sprinklers / . ~. y' / . a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge? ~es D No r b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) [).Yes DNo c. Are quick response and residential spriQklers less than 20 years old? (Older sprinklers require sample testing) ctY~s 0 No d. Is stock of spare sprinklers available? O:Yes 0 No e. Does the exterior condition of sprinkler system appear to be satisfactory') aYes D No f. Are sprinklers of proper temperature (~ing for their locations) aYes D No g. Are any s~ler heads on a recall list? DYes 'QNo ., Signature: Date: ) ,,/ SUMMIT FIRE PROTECTION WORK ORDER DA YWORK # 326715 DATE DUE 5/9/2008 DATE TAKEN 5/6/2008 JOB SUPT JEFF PHONE # 612-325-0762 BY ~ c::rn. vy-) ~ GENERAL CONTRACTOR KEYLAND REMODELING OFFICE# PRIOR LAKE PROJECT MANAGER PHONE JOB SITE INFO: GA TEW A Y CENTER 5117 GATEWAY ST. SE PRIOR LAKE Buildin~ Information BLDG. OWNER: ALM CO: ENGINEER: ELIZABETH ALM. PH: ENG. PH: ACCT. #: I MN SECURITY PH: 952-736-4349 PN #: BLDG. NOTES: PERMIT PLAN REQUEST TECH PO# MAT ORDERD TRUCK STOCK LOCK BOX DECK HGT. LIFT CALL TO SCH: YES / NO CEILING REQ: Y / N / EXT. WALLS REQ: Y / N / EXT. LIGHTS REQ: Y / N / EXT. CONTRACT AMT. NTE600.00 HEAD COUNT # DAY'S 1/4 # FITTERS DESCRIPTION OF WORK: ADD HEAD UNDER GARAGE DOOR IN SHOE REPAIR SHOP. RELOCATE HEAD TO DECK IN PAINT STORAGE AREA OF NAP A AUTO. USE EXISTING OPENING FROM DROP. WORK DONE AS ABOVE YES IF NOT, LIST WORK PERFORMED BELOW: I DATE SERVICE MAN HOURS REG OT DT DA YWORK # 322133 JOB SUPT JEFF GENERAL CONTRACTOR PROJECT MANAGER JOB SITE INFO: GATEWAY CENTER 5117 GATEWAY ST. SE PRIOR LAKE PERMIT PLAN REQUEST TECH PO# CONTRACT AMT. $150.00 DESCRIPTION OF WORK: BRING HORN TO JOBSITE WORK DONE AS ABOVE DATE SERVICE MAN SUMMIT FIRE PROTECTION WORK ORDER DATE DUE PHONE # 612-325-0762 5/6/2008 KEYLAND REMODELING PRIOR LAKE BLDG. OWNER: ENGINEER: ENG. PH: MN SECURITY PH: BLDG. NOTES: MAT ORDERD TRUCK STOCK LOCK BOX DECK HGT. LIFT HEAD COUNT ~lIl YES DATE TAKEN 5/1/2008 BY ANGELA SWEET OFFICE# PHONE Buildin!=l Information . "ALM CO: ALM. PH: ACCT. #: PN#: . CALL TO SCH: YES 1 NO CEILING REQ: Y 1 N 1 EXT. WALLS REQ: Y 1 N 1 EXT. LIGHTS REQ: Y 1 N 1 EXT. # DAY'S 1/4 # FITTERS IF NOT, LIST WORK PERFORMED BELOW: HOURS REG OT DT