HomeMy WebLinkAbout99-099 Subject
~..'~; .,. ."~.,,,-' .
FILE COpy
January 18,2000
Charles Radloff
9979 Valley View Road #256
Eden Prairie, MN 55344
RE: Conceptual Review of Stone gate Apartments (Revisions)
Dear Mr. Radloff,
The following are Zoning comments based on preliminary review of revisions made
to your original proposed project:
Apolications required
1. A Conditional Use Permit is required for Multiple Family Dwelling in the R-4
zoning district.
2. A variance to height is required.
Reauired Plan Chane:es
1. Side yard setback is to increased 31 feet due to sidewall exceeding 50 feet.
This additional side yard setback applies to all portions ofthe structure.
2. Dwelling units need to be at or above grade for a distance of 25 feet beyond
the building. The proposed plan shows only 20 feet.
3. Concrete curbed and landscaped traffic islands at the end of parking rows are
required. Turn around in parking lot and underground parking area is needed.
4. portion of driveway leading to garage is located within the R-O-W. This is
unacceptable. 24 Foot maximum driveway width at property line.
5. Per Section 1107.2202 (b), no unbroken wall may exceed a ration of 4:1 wall
length to building height. Need to make adjustments to building line on all
walls exceeding 124 feet in length.
Additional information needed
1. Need existing and proposed contours.
2. Need lighting plan. Average parking lot 0.4 to 1.0-foot candles. Maximum
foot-candles at property line is 0.5. Maximum pole height is 45 feet.
L:\99FILES\99SUBJEC\99-099\O 11800L TR.doc 1
16200 Eagle Creek Ave. S.E., Prior Lake, Minnesota 55372-1714 / Ph. (612) 447-4230 / Fax (612) 447-4245
AN EQUAL OPPORTUNITY EMPLOYER
-- --- -,/
3. Need a landscape plan prepares by a registered landscape architect. One tree
per unit is required. Parking lot screening is required. This includes a 30-inch
berm with planting to achieve 80% opacity year round. Show on grading and
landscape plans. Buffer yard type "B" is required adjacent to Toronto Avenue
and 170th Street. This is in addition to required planting. Irrigation proposed?
4. Survey is required with all setbacks shown and building dimensions indicated.
Indicate lot area, building coverage, density.
5. Exterior elevations to determine architectural materials. 60% must be of Class
I materials. Wood or vinyl siding is not a Class I material.
6. Utility plan indicating existing/proposed size and location water and sewer
lines and hydrants.
Please note engineering and building department items as listed in my letter dated
12/21/99 have not been re-addressed. These items remain outstadning. Please let me
know if you have any questions.
CC: Sue McDermott, Assistance City Engineer
Robert Hutchins, Building Official
Jane Kansier, Planning Coordinator
L:\99FILES\99SUBJEC\99-099\O 11800L TR.doc
2
FILE COpy
December 21, 1999
~~
~d '}'4JcO
l~tJ/
10{).
Charles Radloff
9979 Valley View Road #256
Eden Prairie, MN 55344
RE: Conceptual Review of Stonegate Apartments
Dear Mr. Radloff,
The following are Zoning comments based on preliminary review of your proposed
project:
Applications reauired
fJeJtl -1. A Conditional Use Permit is required for Multiple Family Dwelling in the R-4
zoning district.
-2. A variance to allow access from a local street may be required:""~ ~aI.<<;I
~oJ. -3. A variance to height may be required.--- ~es '-/0 I ~') I\J'" prq:>c>Vcl.
Required Plan Chane:es
~~' M
oj L - 1. Building is to be 15 feet from the back of ctirb; plan shows approximately 14
feet or 15 feet to front of curb. ,,~- pv1- dj~SiDh 4v ~A..J-" ~~ 4Y~o....
61L. -"'" 2. Front Yard setback ~ or height of building less 9 feet for parking L 1-;0
bonus. ~ 4(;) 71:1. -:: ~ . ~ I t>.,I.-y~ 0(\\0 . ~ mv,s t ~
~..c;./t..lO. - ~IO\lWh>>rf1- OJ'-'
Side yard setback is-lj .feetor ~ height of building less 9 feet for parking ,
C~5~~~ 'f{,)-~ ~ 31 ".o~::. I~("'"
bonus. 31
Side yard setback is to increased ~ feet due to sidewall exceeding 50 feet. 1>37.';>5 -St> =
~ase side yard setbac~ is determine.d from building height. This additional 181;',;; : ;J;: ,J.
SIde yard setback applIes to all portIons of the structure. ~
~. -5. Dwelling units need to be at or above grade for a distance of25 feet beyond -~s' OJ '
the building. The proposed plan shows only 20 feet. <.V 4J~_ !S" ~
/V'---LJ.., -6. Concrete curbed and landscaped traffic islands at the end of parking rows are
required. -~d f.t... 11Iv/'\ tV(),/n.d:J. ~,J I".j""'t "jC<AiIoj< fl..... tAMv-d,
o ~ - 7. Parking lot setback is to be the same as front yard building setback
(determined by building height). 3 I I
t""fJJ~ , - 8. Portion of driveway leading to garage is located within the R-O- W. This is
unacceptable. d41~ JJ,'~ 4Jid}h @. (:J(()f l.u,.<-. ItVI'
/f"\IUJ ---9. Per Section 1107.2202 (b), no unbroken wall may exceed a ratio(of 4:1 wall I ~ -,
length to building height. Need building height to determine compliance. ~ I.f ~ :;) .
YO: :l'3'7.";)r' ~ 6Y\ bcst'h 4>A.) <5j~.+-etJ,J -(1aK'S
\ \FS 1 \SYS\DEP1\PLANNING\99FILES\99SUBJEC\99-099\122199L TR.doc 1
16200 Eagle Creek Ave. S.E., Prior Lake, Minnesota 55372-1714 / Ph. (612) 447-4230 / Fax (612) 447-4245
AN EQUAL OPPORTUNITY EMPLOYER
ok_ --,3.
~J- -4.
-.'.
~1.
f'rJJ-J - 2.
~ -3.
~~-4.
~J -5.
~J _6.
~ -7.
/)A-Dit. - 1.
/V'I.A> ~ - 2.
V WAJ(:) ViI flul'" - 3.
~-4.
I'f'-..>>& -5.
~-6.
~cJ -7.
8.
~,/ < ~,,{']
~~~. ;
3.
4.
~'dY' ,
---.'/ ~
n1lJ1 T. ~IO
-, 11A~'
~ .<:1
JI'" J
u'~ ~D
~
Need elevations at all streets to determine base for building height. The
building height will determine setbacks. Variance to height appears to be
needed.
Need existing and proposed contours to determine building height.
Need lighting plan. Average parking lot 0.4 to 1.0-foot candles. Maximum
foot-candles at property line is 0.5. Maximum pole height is 45 feet.
Need a landscape plan prepares by a registered landscape architect. One tree
per unit is required. Parking lot screening is required. This includes a 30-inch
berm with planting to achieve 80% opacity year round. Show on grading and
landscape plans. Buffer yard type "B" is required adjacent to Toronto Avenue
and 170th Street. This is in addition to required planting. Irrigation proposed?
Survey is required with all setbacks shown and building dimensions indicated.
Indicate lot area, building coverage, density.
Exterior elevations to determine architectural materials. 60% must be of Class
I materials. Wood or vinyl siding is not a Class I material.
Utility pIan indicating existing/proposed size and location water and sewer
lines and hydrants.
Additional information needed
Comments
All utilities are to be underground.
6" Cast in place concrete is required.
Link to trails and sidewalks is required.
Signs require separate plan and permit.
Minimum parking stall size is 18 feet by 8.5 feet. Appears to be met, need
stall width indicated on plan. .
Parking and drive areas are to be hard surfaced with curb and gutter.
Maximum driveway slope is 10%. Show on grading plan.
Your plan indicates a community room requirement. This is only required for
Elderly housing. Will the building be elderly housing?-;VO
9. A Letter of Credit is required for 125% oflandscaping costs.
10. 1 % of lot area is to be used for plazas or walkways.
11. What is the size of roof overhangs? Are any awnings proposed? - ,{J 0
~l
Items to be clarified
-r1I fluo....vJ .......--10 1.1Y\~ -0. L-
Is ther~t;C~rtyr management office on site?--(tn111W'hI/ I
Is this r a condo building? - ole...-
Is there a outside trash enclosure? \~slM ~~
Is there exterior or rooftop mechanica ipment? ~n rc.;t
-3 - ~-.
t.\w g
'1
\\FS 1 \SYS\DEP1\PLANNING\99FILES\99SUBJEC\99-099\122199L TR.doc
2
The Engineering Department has reviewed the subject submittal and have
determined that the following items must be shown on the plans:
1. Existing elevations and features such as buildings, curb, trees, fencing, etc., on
the site and a minimum of 50 feet around the perimeter.
2. All wetlands on site must be delineated.
3. All existing and proposed easements.
4. Proposed ponding areas must match the drainage calculations. All ponds shall
meet current city requirements.
5. Proposed contours and proposed curb spot elevations.
6. Drainage arrows, direction and percent of slope of all drainage
7. A rip rap area (8' x 20') with concrete pad at all curb cuts.
8. Silt fence detail and hydrant detail.
9. Type of concrete curb proposed.
10. Parking lot pavement section.
11. Plan must match Certificate of Survey (elevations).
12. Grading limits.
13. Erosion control.
14. Grading plan must be signed by a registered professional engineer.
Following are the results of the preliminary building plan review;
~ubmit signed architectural, structural, site, utility plans and a Certificate of
\::J Survey.
2. Submit signed HV AC, plumbing, fire alarm, and sprinkler plans. May be
submitted at a later date.
3. Submit the Structural Engineers requirements for Special Inspections UBC
1701.5. See enclosed.
4. Anchoring of retaining wall must be located on parcel. Engineering required on
retaining walls over 4 feet in height.
5. Complete a Building Code analysis.
6. Provide the Illumination Budget Calculation Summary, MN Energy Code Part
7670.080.
7. An S.A.C. determination must be completed by the Metropolitan Waste
Control Commission. Contact Jody Edwards at 651.602.1113.
8. Submit Energy Envelope Calculations. MN Energy Code 7670.0100
9. Submit a soils report.
10. Address UBC sections 706 Fire-resistive Joints, 708 Draft stops, 709
Penetrations, 710 Floor Ceilings, and 711 Shaft Enclosures.
11. Provide detail of occupancy separation penetration firestopping. UBC 106.3.3
12. Ventilation for the building must meet UBC chapter 12. Provide 15 CFM of
ventilation per occupant in the Apartments and 3/4 CFM per square
foot of floor area in the Parking Garage.
13. Provide emergency lighting and exit signs. UBC 1003.2.8
14. One hour fire-rated Elevator Lobbies required. UBC 1004.3.4.5
15. Provide an Area of Refuge. UBC 1104.2.
\ \FS 1 \SYS\DEP1\PLANNING\99FILES\99SUBJEC\99-099\122199L TR.doc
3
, .':"_'. ..'".. ....w<;..._.~.~._.. ,... a
~/
#
16. Provide an accessible drinking fountain and a cutsheet detail. MSBC
1305.1795
17. Provide HDCP signage details.
18. Provide accessible route from exterior HDCP parking to the building. MSBC
1340.1103
19. Two percent of Units must be HDCP Accessible, remainder must be
adaptable. MSBC 1341 Table 16.2 See enclosed.
20. Provide a Fire Hydrant within 150 feet of the Fire Department connection and
all areas of the building shall be within 300 feet of a Fire Hydrant.
21. A monitored alarm system required with over 20 sprinklers. MSFC 1003.3.1
22. Provide fire extinguishers minimum 2AI0BC rated, within 75 feet travel
distance of all areas. UFC 1002.
23. Provide a Class I standpipe in each stairway. UBC 904.5.3
24. Provide not less than one standpipe for use during construction. UBC 904.6.2
25. Provide two parking spaces for commuter van. MSBC 1300.4100.
26. Provide a recycling space. MSBC 1300.4700.
27. Automatic garage doors to comply with State of Minnesota Statutes. MSBC
1300.5900
This is a preliminary review only on conceptual plans. A complete review will be
conducted upon submittal of a Conditional Use Permit Application. If you have any
questions regarding these comments or how to proceed with a conditional use permit
application, please call me at (612) 447-9813.
J . Tovar
Planner
CC: Sue McDermott, Assistance City Engineer
Robert Hutchins, Building Official
Jane Kansier, Planning Coordinator
\\FS 1 \SYS\DEPT\PLANNING\99FILES\99SUBJEC\99-099\122199L TR.doc
4
CITY OF PRIOR LAKE
ORC PROJECT REVIEW CHECKLIST
PROJECT NAME: Stonegate Apartments
Concept Review. Please review the attached concept plan. I
would like to meet with them for plan changes and additional
informaiton required.
APPLICANT: Charles Radloff
CONTACT PERSON: Charles Radloff (612) 941-1667
SITE INFORMATION
PID#:
LOCATION: SW Corner of Tower and Toronto (previously City owned
property)
EXISTING ZONING: R-4 Multi-family Residential
DISTRIBUTE TO: I APPLICATION FOR:
X Frank Boyles I Administrative Land Division
X Sue McDermott Comprehensive Plan Amend.
Ralph Teschner Jeff Evens Conditional Use Permit
Paul Hokeness Lani Leichty Home Occupation
X Bob Hutchins Verlyn Raaen Rezoning
X Don Rye Doug Hartman Site Plan
X Jane Kansier Fire Chief Preliminary Plat
X JenniTovar Bill O'Rourke PUD
DNR - Pat Lynch Minnegasco Final Plat
County Hwy. Dept. Watershed Dist. Variance
MNDOT Telephone Co. Vacation
SMDC Electric Co. X Conceptual Site Plan Review
Triax Cable Met. Council
Date Received 12/3/99 Date Distributed 12/8/99 Date Due 12/17/99
Complete Application N/A Date Distributed to 12/8/99 DRC Meeting 12/9/99
Date DRC
Publication Date N/A Tentative PC Date N/A Tentative CC N/A
Date
60 Day Review Date N/A Review Extension N/A
f:\dept\planning\99files\99subjec\99-099\referral.doc
Page 1
I have reviewed the attached proposed request Stonegate Apartments CASE FILE 99-
099 for the following:
,/ Water City Code ,/ Grading
V Sewer Storm Water Signs
Zoning Flood Plain County Road Access
Parks Natural Features Legal Issues
Assessment Electric Roads/Access
Policy
Septic System Gas Building Code
if Erosion Control Other
Recommendation:
Approval
Denial
Conditional Approval
Signed:
-> &kJ).OJ~
Date:
I~ro !ec'l
t I
Please return any comments by December 17, 1999, to
Jenni Tovar, Planner
City of Prior Lake
16000 Eagle Creek Avenue SE
Prior Lake. MN 55372
Phone: (612) 447-9813
Fax: (612) 447-4J45
f:\dept\planning\99files\99subjec\99-099\referral.doc
Page 2
I have reviewed the attached proposed request Stonegate Apartments CASE FILE 99-
099 for the following:
Water City Code Grading
/ Sewer Storm Water Signs
X Zoning Flood Plain County Road Access
, Parks Natural Features Legal Issues
Assessment Electric Roads/Access
Policy
Septic System Gas Building Code
Erosion Control Other
Recommendation:
Approval
Denial
Conditional Approval
;ommL0~ LYJ ~~ - ~ ~rMMv &fuuJA
· ~1:b~ - ..u 7iJJ.h ....-
. ~ -1-0 ()L'~ 11\16 ..A/Y1 Ii Jt I V l..iALfrv .nd.~ /1~ IP.i\IV.LA -'f - hi.. ~
~ J.~ 7
" rj ~J1_ACOt < · M?_
"
ft.114s~
.
~
Jl4{'t\O.l~
Signed: ~ Date: I~J()/qCj
Please return any comments by December 17. 1 g::11~ _ ,-(
Jenni Tovar, Planner n ,..... \
City of Prior Lake VU -\
16000 Eagle Creek Avenue SE
Prior Lake, MN 55372 . \
Phone: (612) 447-9813,\
Fax: (612) 447-4245 \L)
~/~
f:\dept\planning\99files\99subjec\99-099\referral.doc
"\
\
\
I
~~\ --
Page 2
0).
C?
I /. /" / ,.
r-;;:-
\ ,., , ,., ,/
,..- ,.
m ::D\ , r ,.-
, ,/ ,/
~ /'
tn m\ /'
m 0 \
3:: /
C \
m - /
z :u I
-t m I
=-= C I~
Q) I
0) CD I ~
<.. -r. 0
o~ I , ~
....
? <:) ~
....
<:) 0
~
~
(fl
I I
I ,
I I
I ,
I I
I
I I
I
I
\
\
rn...
p ';
:D
!<
r
m
)0-
:D
Z
Z
Ii)
o
m
z
~L\ ~
~'b :D
01-;
J:;
~
(\p
?~
~
~<J
~
0 1
tn
I\) 0
UI )>
r- .;-,.,.. .
m N
UI
0
\
\ /1q (}
\
170TH STREET
C?
.
~IDGE ESTATES 1ST ADDITION
Y.
I have reviewed the attached proposed request Stonegate Apartments CASE FILE 99-
099 for the following:
Water City Code Grading
Sewer Storm Water Signs
Zoning Flood Plain County Road Access
Parks Natural Features Legal Issues
Assessment Electric Roads! Access
Policy
Septic System Gas Building Code
Erosion Control Other
Recommendation:
Approval
JDenial
Conditional Approval
Comments:
S-t:~
yY\~"'O
To
"--\~ e;: ~ , lz)..,lcrt
Signed:
Date:
"-
Please return any comments by December 17, 1999, to
Jenni Tovar, Planner
City of Prior Lake
16000 Eagle Creek Avenue SE
Prior Lake, MN 55372
Phone: (612) 447-9813
Fax: (612) 447-4245
f:\dept\planning\99files\99subjec\99-099\referral.doc
Page 2
. .
Memorandum
DATE: December 17,1999
TO: Jane Kansier, Planner
FROM:
Robert D. Hutchins, Building Official
fDlk
RE: Stonegate Apartments Toronto Ave.
Following are the results of the preliminary plan review for the Stonegate Apartment building.
Our review was based on the Minnesota State Building Code (MSBC) which adopted with
amendments the 1997 Uniform Building Code (UBe) with handicap regulations of the
Minnesota Accessibility Code Chapter 1341 and with requirements of the 1998 Minnesota State
Fire Code (MSFC) which adopted with amendments the 1997 Uniform Fire Code (UFC).
1. Submit signed architectural, structural, site, utility plans and a Certificate of Survey.
2. Submit signed HV AC, plumbing, fire alarm, and sprinkler plans. May be submitted at
a later date.
3. Submit the Structural Engineers requirements for Special Inspections UBC 1701.5. See enclosed.
4. Anchoring of retaining wall must be located on parcel. Engineering required on
retaining walls over 4 feet in height.
5. Complete a Building Code analysis.
6. Provide the Illumination Budget Calculation Summary, MN Energy Code Part
7670.080.
7. An S.A.C. determination must be completed by the Metropolitan Waste Control
Commission. Contact Jody Edwards at 651.602.1113.
8. Submit Energy Envelope Calculations. MN Energy Code 7670.0100
9. Submit a soils report.
10. Address UBC sections 706 Fire-resistive Joints, 708 Draft stops, 709 Penetrations,
710 Floor Ceilings, and 711 Shaft Enclosures.
11. Provide detail of occupancy separation penetration firestopping. UBC 106.3.3
, .
12. Ventilation for the building must meet UBC chapter 12. Provide 15 CFM of
ventilation per occupant in the Apartments and 3/4 CFM per square foot of floor area
in the Parking Garage.
13. Provide emergency lighting and exit signs. UBC 1003.2.8
14. One hour fire-rated Elevator Lobbies required. UBC 1004.3.4.5
15. Provide an Area of Refuge. UBC 1104.2.
16. Provide an accessible drinking fountain and a cutsheet detail. MSBC 1305.1795
17. Provide HDCP signage details.
18. Provide accessible route from exterior HDCP parking to the building. MSBC
1340.11 03
This is a preliminary review only on conceptual plans. Other code items will be addressed
when the preliminary plans are submitted. The building plans must be reviewed by the
Cities Developmental Review Committee (DRC) which consists of representatives of
Planning, Engineering, Parks, Finance, and Building Departments. The DRC must
approve the plans before a building permit can be issued.
2
CITY OF PRIOR LAKE
16200 EAGLE CREEK AVENUE S.E.
PRIOR LAKE, MN 55372
SPECIAL STRUCTURAL TESTING AND INSPECTION SCHEDULE
Project Name
Location
SPECIAL STRUCTURAL TESTING AND INSPECTION
Specification Description Type of Inspector (3) Report Frequency Assigned
Section Article Firm (4)
Notes: This schedule to be filled out and included in the project specification. Information unavailable at that time,
to be filled out when applying for a building permit.
(1) Use descriptions per UBC Section 1701, as adopted by Minnesota State Building Code.
(2) Special Inspector - Technical, Special Inspector - Strucural.
(3) Firm contracted to perform services.
ACKNOWLEDGMENTS
Each appropriate representative shall sign below:
Owner: Firm: Date:
Contractor: Firm: Date:
Architect: Firm: Date:
SER: Firm: Date:
SI-S: Firm: Date:
TA: Firm: Date:
SI- T: Firm: Date:
T A: Firm: Date:
SI- T: Firm: Date:
F: Firm: Date:
F: Firm: Date:
*The individual names of all prospective special inspectors and the work they intend to observe shall be
identified. (Use reverse side ofform if necessary.)
Legend: SER = Structural Engineer of Record
SI- T = Special Inspector - Technical
SI-S = Special Inspector - Structural
TA = Testing Agency
F = Fabricator
Accepted for the Building Department by
Date
SSTl.DOC
Dwelling Unit Checklist
This checklist covers individual dwelling units. See 1341.1620 to determine if the
development is a covered development and which dwelling units are covered dwelling
units. 1341.16xx may provide clarification on certain issues or requirements for unique
situations which are not contained in this checklist.
Adaptable Dwelling Units I Accessible Dwelling Units
Primary entry door is fully accessible Primary entry door is fully accessible
with proper floor clearances on latch with proper floor clearances on latch
side of door. side of door.
All passage doors within unit have a All passage doors within unit are fully
minimum clear opening of 32 inches. accessible with proper floor clearances
on latch side of door.
An accessible route leads to all rooms An accessible route leads to all rooms
and spaces within the unit. and spaces within the unit.
All light switches, electrical outlets and All light switches, electrical outlets and
environmental controls are no more environmental controls are no more
than 48 inches above the floor. than 48 inches above the floor.
Clear floor space for a parallel Clear floor space for a parallel
approach is centered on the range, approach is centered on the range and
cooktop and sink, OR, a forward cooktop, OR, a forward approach with
approach with knee clearance or knee clearance or removable cabinet is
removable cabinet is provided. provided.
The rim of the sink is no more than 34
inches above the floor and a forward
approach with knee clearance or
removable cabinet is provided.
A work space at least 30 inches wide,
with the counter top no more than 34
inches above the floor, and knee
clearance or removable cabinet is
provided.
Either a parallel or forward approach is Either a parallel or forward approach is
centered on the oven, dishwasher, centered on the oven, dishwasher,
refrigerator/freezer, trash compactor, or refrigerator/freezer, trash compactor, or
other appliance. other appliance.
The minimum clearance between all The minimum clearance between all
opposing counters, cabinets, appliances opposing counters, cabinets, appliances
and walls is 40 inches. Note - if a and walls is 40 inches. Note - if a
parallel approach is required to an parallel approach is required to an
appliance located at the base of aU appliance located at the base of a U
shaped kitchen, a 60 inch turning shaped kitchen, a 60 inch turning
diameter is required. diameter is required.
Adaptable Dwelling Units Accessible Dwelling Units I
All toilet rooms and bathrooms located on All toilet rooms and bathrooms shall be
an accessible route shall be adaptable. accessible.
A 30 inch by 48 inch clear floor space A 30 inch by 48 inch clear floor space
is provided within the room that is clear is provided within the room that is clear
of the swing of the door. of the swing of the door.
i Supports are provided to mount grab ! Grab bars are installed at the toilet, tub
, bars at the toilet, tub or shower (see I or shower (see 1341 figures 80, 81 and
1341 figures 80, 81 and 82). 82).
Supports are provided so that a grab bar A grab bar is installed 18 inches from
can be mounted 18 inches from the the centerline of the water closet on at
centerline of the water closet on at least least one side of the water closet.
one side of the water closet.
Floor clearances next to water closet Floor clearances next to water closet
are provided according to 1341 figure are provided according to 1341 figure
83. Note - water closet is not required 83. Note - water closet is not required
to be located adjacent to a side wall as to be located adjacent to a side wall as
shown in figure. shown in figure.
An encroachment is allowed on one An encroachment is allowed on one
side of the water closet starting at least side of the water closet starting at least
15 inches from the centerline of the 15 inches from the centerline of the
water closet and extending a maximum water closet and. extending a maximum
of 24 inches from the rear wall. of 24 inches from the rear wall.
A clear floor space that allows either a A clear floor space for a forward
parallel or forward approach is centered approach is centered on the sink. Knee
on the sink. If only a forward approach clearance or removable cabinet is
is provided, knee clearance or provided.
removable cabinet is provided.
The rim of the sink is no more than 34 The rim of the sink is no more than 34
inches above the floor. inches above the floor.
A clear floor space a minimum of 30 A clear floor space a minimum of 30
inches wide is provided next to the inches wide is provided next to the
bathtub for the entire length of the tub. bathtub for the entire length of the tub.
Note - a vanity or water closet may Note - a vanity or water closet may
encroach at the control end of the tub; encroach at the control end of the tub;
see 1341.1640, Item E, Subitem (4). see 1341.1640, Item E, Subitem (4).
A clear floor space 30 inches by 48 A clear floor space 30 inches by 48
inches is provided adjacent to the inches is provided adjacent to the
shower. shower.
If a shower is the only bathing fixture If a shower is the only bathing fixture
provided in the dwelling unit, it provided in the dwelling unit, it
measures a minimum of 36 inches by measures a minimum of 36 inches by
36 inches and has supports for 36 inches and has supports for
installation of a shower seat. installation of a shower seat.
. When 3 or more accessible dwelling
units are required, at least one dwelling
unit has a roll-in shower.