HomeMy WebLinkAboutSprinkler Report 12/4/08 Fire Sprinkler System Inspection Report ~ G I L B E R T Gilbert Mechanical Contractors, Inc. 4451 West 76th Street Edina, MN 55435 (952) 835-3810 Inspected By: Dean Kaminski Inspection Date: 12/04/2008 Inspection #: 2743 Bill To: Air-Pur Systems Bill To Address: 16873 Fish Point Road SE Prior Lake, MN 55372 Property Name: Air-Pur Systems Property Address: 1 Ei873 Fish Point Road SE Prior Lake, MN 55372 Contact & Phone #: Contact: Was owner representative contacted prior to inspection? Representative's Name: Rep present during inspection? OVes 0No * Were all rooms available for inspection? 0 Ves a No Are as-built drawings available? OVes 0No o Yes 0 No Date Contacted: Rep's Name: Last inspection report available? 0Ves a No Zone map available? aVes 0 No * If no, see notes on following page [Z] GENERAL SYSTEM INFORMATION 1 # of Systems 1 # of Wet # of Dry # of Preacltion # of Other No date of install Location of Valve Assl3mbly: Warehouse [Z] SPRINKLER SYSTEM INSPECTION System components have been inspected as follows: (circle all that apply) Gauges (Dry, Preaction, Deluge) OVes ONa 0N/A o Other (see notes) Waterflow Devices 0Ves ONo ON/A o Other (see notes) Valve Supervisory Devices 0Ves ONo ON/A o Other (see notes) Supervisory Signal Delvices (Except Valve) o Yes ONo 0N/A o Other (see notes) Supervisory Switches OVes ONo 0N/A o Other (see notes) Gauges (Wet System) 0Ves ONo ON/A o Other (see notes) Hydraulic Nameplate 0Ves ONo ON/A o Other (see notes) Buildings 0Ves ONa ON/A o Other (see notes) Hanger/Seismic Bracing 0Ves ONa ON/A o Other (see notes) Pipe & Fittings 0Ves ONo ON/A a Other (see notes) Sprinklers 0Ves ONo ON/A o Other (see notes) Spare Sprinklers o Yes ONo ON/A o Other (see notes) Fire Department Connection 0Ves ONo ON/A a Other (see notes) Page 1 of 8 [l] SPRINKLER SYSTEM INSPECTION Valves (All Types) o Yes ONo ON/A o Other (see notes) Control Valves 0Ves ONo ON/A o Other (see notes) Alarm Valves OVes ONo 0N/A o Other (see notes) Check Valves OVes ONo 0N/A o Other (see notes) Pre-Action/Deluge o Yes ONo 0N/A o Other (see notes) Dry Pipe Valves o Yes ONo 0N/A o Other (see notes) Pressure Reducing & Relief o Yes ONo 0N/A o Other (see notes) Backflow Prevention Assemblies 0Ves ONo ON/A o Other (see notes) Sprinkler System Inspection Notes: [l] OBSTRUCTION INVESTIGATION NFPA 25 (2002) "An investigation of piping and branch line conditions shall be conducted every 5 years by opening a flushing connection at the end of one main and by removing a sprinkler toward the end of one branch line for the purpose of investigating for the presence of foreign organic and inorganic material." (Stated in NFP A 25, 2002 Chapter 13.2.1) Has the owner been informed of the obstruction investigation requirement? Date last obstruction investigation was performed: Is an obstruction investigation required with this inspection? *If Yes, owner's authorization: Has an obstruction investigation been performed? OVes 0No o Yes * 0 No (Owner/Rep name) OVes ONo Obstruction Investigation Notes: Page 2 of 8 -t-. D Fire Sprinkler System Inspection Report STANDPIPE & HOSE SYSTEM INSPECTION System components have been inspected as follows: (circle all that apply) Control Valves OVes ONo ON/A o Other (see notes) Pressure Regulating Devices OVes ONo ON/A o Other (see notes) Piping OVes ONo ON/A o Other (see notes) Hose Connections OVes ONo ON/A o Other (see notes) Cabinet OVes ONo ON/A o Other (see notes) Hose OVes ONo ON/A o Other (see notes) Hose Storage Device OVes ONo ON/A o Other (see notes) Hose Nozzle OVes ONo ON/A a Other (see notes) Standpipe and Hose System Inspection Notes: D PRIVATE FIRE SE~VICE MAIN INSPECTION System Components 11ave been Inspected as Follows: (circle all that apply) Hose Houses OVes ONo ON/A o Other (see notes) Hose Hydrants (Dry Barrel & Wall) aVes ONo ON/A o Other (see notes) Monitor Nozzles OVes ONo ON/A o Other (see notes) Hydrants (Wet Barrel) OVes ONo ON/A o Other (see notes) Mainline Strainers OVes ONo ON/A o Other (see notes) Piping (Exposed) OVes ONo ON/A o Other (see notes) Piping (Underground) OVes ONo ON/A o Other (see notes) Private Fire Service Main Inspection Notes: D FIRE PUMP INSPECTION & TESTING (see Fire Pump Inspection form on separate page) Page 3 of 8 D WATER STORAGE TANK INSPECTION Fire Sprinkler System Inspection Report System components have been inspected as follows: (circle all that apply) Condition of Water in Tank OVes ONo ON/A o Other (see notes) Water Temperature Heating System OVes ONo ON/A o Other (see notes) Control Values OVes ONo ON/A o Other (see notes) Water Level OVes ONo ON/A o Other (see notes) Air Pressure PSI Tank Exterior o Yes ONo ON/A o Other (see notes) Support Structure OVes ONo ON/A o Other (see notes) Catwalks and Ladders OVes ONo ON/A o Other (see notes) Surrounding Area OVes ONo ON/A o Other (see notes) Hoops & Grillage o Yes ONo ON/A o Other (see notes) Painted/Coated Surfaces OVes ONo ON/A o Other (see notes) Expansion Joints o Yes ONo ON/A o Other (see notes) Interior OVes ONo ON/A o Other (see notes) Check Valves o Yes ONo ON/A o Other (see notes) Water Storage Tank Inspection Notes: Page 4 of 8 D WATER SPRAY FIXED SYSTEM INSPECTION Fire Sprinkler System Inspection Report System components have been inspected as follows: (circle all that apply) Backflow Preventer o Yes ONo ON/A o Other (see notes) Check Valves OVes ONo ON/A o Other (see notes) Control Valves OVes ONo ON/A o Other (see notes) Deluge Valves o Yes ONo ON/A o Other (see notes) Detection Systems OVes ONo ON/A o Other (see notes) Detector Check Valves o Yes ONo ON/A o Other (see notes) Drainage o Yes ONo ON/A o Other (see notes) Electric Motor OVes ONo ON/A o Other (see notes) Engine Drive OVes ONo ON/A o Other (see notes) Fire Pump OVes ONo ON/A o Other (see notes) Fittings o Yes ONa ON/A o Other (see notes) Fittings (Rubber-Gasketed) OVes ONo ON/A o Other (see notes) Gravity Tanks o Yes ONo ON/A o Other (see notes) Hangers OVes ONo ON/A o Other (see notes) Heat (Deluge Valve House OVes ONo ON/A o Other (see notes) Nozzles o Yes ONo ON/A o Other (see notes) Pipe OVes ONo ON/A o Other (see notes) Pressure Tank OVes ONo ON/A o Other (see notes) Steam Driver OVes ONo ON/A o Other (see notes) Strainers OVes ONo ON/A o Other (see notes) Suction Tanks OVes ONo ON/A o Other (see notes) Supports OVes ONo ON/A o Other (see notes) Water Supply Piping OVes ONo ON/A o Other (see notes) UHSWSS-Detectors OVes ONo ON/A o Other (see notes) UHSWSS-Controllers OVes ONo ON/A o Other (see notes) UHSWSS-Valves OVes ONo ON/A o Other (see notes) Water Spray Fixed System Inspection Notes: Page 5 of 8 D FOAM WATER SPRINKLER SYSTEM INSPECTION Fire Sprinkler System Inspection Report System components have been inspected as follows: (circle all that apply) Discharge Device Location (Sprinkler) o Yes ONo ON/A o Other (see notes) Discharge Device Location (Spray Nozzle) o Yes ONo o N/A o Other (see notes) Discharge Device Position (Sprinkler) o Yes ONo ON/A o Other (see notes) Discharge Device Position (Spray Nozzle) o Yes ONo o N/A o Other (see notes) Foam Concentrate Strainer o Yes ONo ON/,tI. o Other (see notes) Drainage in System Area o Yes ONo o N/A o Other (see notes) Proportioning System(s) - All o Yes ONo o N/A o Other (see notes) Pipe Corrosion o Yes ONo o N/A o Other (see notes) Pipe Damage o Yes ONo ON/A o Other (see notes) Fitting Corrosion o Yes ONo o N/A o Other (see notes) Fitting Damage o Yes ONo o N/A o Other (see notes) Hangers/Supports o Yes ONo a N/A o Other (see notes) Waterflow Devices o Yes ONo ON/A o Other (see notes) Water Supply Tanks aYes ONo o N/A a Other (see notes) Fire Pump(s) o Yes ONo a N/A o Other (see notes) Water Supply Piping o Yes aNo a N/A o Other (see notes) Control Valves o Yes ONo ON/A o Other (see notes) Deluge/Preaction Valve(s) o Yes ONo o N/A o Other (see notes) Detection System o Yes ONo ON/A o Other (see notes) Foam-Water Sprinkler System Inspection Notes: Sprinkler System Testing D QUARTERLY TESTS Waterflow Devices Water Motor Gong: # Present Did the Alarm Sound: a YES a NO (circle one) Notes: Page 6 of 8 ,. [Z] SEMI-ANNUAL TESTS Waterflow Devices Vane Type # 1 Pressure Switch Type # _ Do All Waterflow Devices Operate Properly: 0 YES o NO (circle one) Notes: Valves Supervisory Devices 2 Do All Supervisory Devices Operate Properly: 0 YES a NO (circle one) # Present Notes: Supervisory Signal Devices # l:Jresent Type: Notes: [Z] ANNUAL TESTS Main Drain Test Static: ~ PSI Antifreeze Solution PSI Residual: 78 Specific Gravity Bit 600 F: OF Freezing Point: Adjustment Needed: aYES a NO (circle one) Notes: Page 7 of 8 D 5 YEAR TESTS Gauges **Gauges shall be replaced every 5 years or tested every 5 years by comparison with calibrated gauuge. Gauges not accurate to within 3% to the full scale shall be recalibrated or reduced. # Present: # Recalibrated: # Tested: # Replaced: Notes: Sprinklers (Extra High Temperature) Date of Initial Installation: o Sprinklers Operate Properly: See Sprinkler Test Report o Replace Sprinklers: See Sprinkler Test Report Date Last Tested: D SPRINKLER TESTING (20 YEARS OR OLDER) Fast Response Sprinklers Date of Initial Installation: o Sprinklers Operate Properly: See Sprinkler Test Report o Replace Sprinklers: See Sprinkler Test Report Date of Last Test: Notes: D SPRINKLERS 50 YEARS OLD OR OLDER Date of Initial Installation: o Sprinklers Operate Properly: o Replace Sprinklers: Date of Last Test: See Sprinkler Test Report See Sprinkler Test Report Notes: [l] Control valves left opened and system placed back in service? 0Ves o No Page 8 of 8