HomeMy WebLinkAboutFire Alarm Insp. 3/18/2009 Metro Alarm "We Save Lives & Protect Property" p.o. BOX 1775 · BURNSVILLE, MN 55337 · SERVICE (952) 890-6684 · FAX (952) 707-6881 · LIC#TS00401 Iii:\ www.metroalarmco.com ~ Underwriters Laboratories Inc. @ ALARM SERVICE #S8526-1 FIRE ALARM INSPECTION AND TEST REPORT I COpy TO: CLIENT_FIRE DEPT. I '" '~ , ~ ACCT. NO Lf S 1- 11'1 ': SERVICE CALL NO. I./t;. q Ii; 0 U.L. CERTIFICATE NO. I DATE5//<;7J/tJq CUSTOMER 'r t1 ff/> I'H""'] T.. {pam CONTACT M/ft,:e Mh YIA/' II I TITLE ADDRESS 46 Cf (f c. (JIM" J 0 )'t 'Sf PHONE q S 7 . Lll/7 - '2 q 0 r I_BI-MONTHLY _SEMI-ANNUAL MONTHLY 2(ANNUAL CITY Pr- f O.r l a. Ke. STATE ,if AI I ZIP !;'" s" .} 7 7 I_QUARTERLY _FINAL CONTROL PANEL MANUFACTURE D/doaraoh MODELNOr; C;qOO LOCATION P}i,:.o;Ont,p,.,f "fddv .rnen' TYPE OF SIGNALING w POWER CIR. BRKR. LOCATION N6. LOCKED CIR BRKR. DEDICATED CIR )LGENERAL ALARM _SELECTIVE SIGNALS _CODED _PRE-SIGNAL SOURCE A"'1Io'I1 So,..v P4"" I ,U1 - YES }C.NO xYES - NO BATTERIES VOLT WITH CHARGER-. i -NOT]} TROUBLE RE~NSE TO ZONE TROUBLE SIGNAL TROUBLE AC/OP POWER LOSS EARTH GROUND VOLT WITHOUT cHbt.m -/ . fArm, CONDITIONS NORMAL NOTE XNORMAL NOTE ~NORMAL NOTE NORMAL NOTE COMMUNICATOR :-"IANUFACTURE 5 A 1"1 F ....-?f,10DEL NO. LOCATION ~A /Y1 FA BATTERIES VOLT WITH c~:d NOTE # POWER CIR. BRKR.YAfION NO. LOCKED ClR BRKR DEDICATED CIR VOLT WITHOU HARGER NEW SOURCE YES NO YES NO CENTRAL MONITORING RESPONSE TO ALARM TROUBLE RESPONSE'TO ZONE TROUBLE SIGNAL TROUBLE AC/OP POWER LOSS EARTH GROUND STATION tNORM. _NOTE # CONDITIONS ~NORMAL _NOTE ~NORMAL _NOTE ~ORMAL _NOTE _NORMAL _NOTE COMMUNICATOR PRIMARY # '15'2 - 447 - q3 6 (. COMMUNICATOR SECONDARY # <j 57 - t..( L( 7- c; 0 ) 7 AUXILIARY FUNCTIONS ANNUNCIATOR (MFG) f I MODEL TYPE - INCAD _GRAPHIC CR~ I VOLTAGE I NO OF ZONES I UNUSED PTS. D, ~~..~..'" /'Ii LED DROP ~CD /2vDC ELEVATOR R~ALL TO PRIMARY FLOOR RECALL TO ALTERNATE FLOOR ELEVATOR RESTART FIRE RECALL _NORMAL - NOTE - N/A - NORMAL _NOTE _N/A FROM FIRE SUe. AUTOMATICALLY - YES _NO SPRINKLER SYSTEM: METRO ALARM'S INSPECTION ONLY INCLUDES A FUNCTIONAL TEST ACTUAL FIRE SPRINKLER TEST WAS DONE BY: TESTED: PERIPHERAL FUNCTION TEST DEVICE L I ""_1 FLOOR VOLTS MFG & MODEL # NOTE Manual Stations 2- 4 I "/7 [ Jnrd . R of R Heat Detectors , Ie OJ (LJoAf,.1Il/~ Fixed Heat Detectors Photo Smoke q <6 3 I ( \I Oc f5L~,.".fpy Ion Smoke .. Duct Smoke , Waterflow GVT PIV Low Air Horns Only Strobes Only Horn / Strobes l S- f 112 vlX G "'" -/QJ' #1 Speaker / Strobes Door Holders I Z LI,,'IX r) --vQn/~ NOTATIONS AND COMMENTS #1 flO,....e ...."'..; fffC l,J -, ~ , rtfl F~i .' / / '-1 L:; f f G .- " / 1/ /I /~C1 / ~~ ILl r /-1 et::l i'-i. II d /"=' - e.-j ,,' (/(J/',.. v . , / .../ / r./" / .<....' CUSTOMER SIGNATURE: SER Su!NAl.~ ~/~, 7 /~:h:"Z . ~~'..ca- / l' fr } //'