HomeMy WebLinkAboutSprinkler Insp. - May 2009 LID #: 3150135 Page 1 of 3 ,",-. ".,~ ~ Ahern Fire Protection 13705 26th Avenue, Suite 110 1\finneapolis, MN 55441 (763) 268-0515 P . (763) 268-0516 f www.ahernfire.com · Since 1880 Annual Sprinkler System Inspection Report Work Order #: 851835 For MonthlYear: May 2009 Invoice: COURTWOOD VILLAGE Street: 17092 ADELMAN ST SE City: PRIOR LAKE Dept.: City: Prior Lake State: MN Zip: 55372 Phone #: (763) 286-4904 State: MN Zip: 55372- Location: Courtwood Village Condos Street: Phone #: Date: 17092 Ade]man Street SE (763) 286-4904 Fax #: (952) 5]3-20]0 Foreman: Jesse Olmanson Signature: Wet Dry Preaction De]uge Stand Pipe/Hose Contacts: Michael Lind Invoice/Deticiency Ron Fitch On Site Foam A]arms Detectors Hydrants FireDoors FirePumps Va]veTT Suppression Anti_Freeze Water Spray BF RP BFDC BF Generic BF Lincoln BF Omaha Internal Sprinkler Direct: (952) 226-] 709 Ext: Cell/Pager: Direct: (763) 286-4904 Ext: Cell/Pager: B]ake Rothnem Invoice/Deficiency Direct: (952) 226-1709 Ext: Cell/Pager: (612) 328-78]5 ALARM DEVICES TESTS ]. Did waterflow or pressure switches operate satisfactorily? 2. Did tamper switches operate satisfactorily? 3. Did water motor alarm gongs or electric bells operate satisfactorily? 4. Did alarm service or central station operate satisfactorily and receive proper signals? ~ \ IALARM SIGNALS System # D/ Test Times /" ,r{ l'..../" 1""" ,,' "' ,-,'rt).. f'll"/' 5 YEAR INSPECTION y ]. Was the 5 year Inspection performed on the following items? A. Alarm valves B. Check valves C. Gauges D. Internal Examination of Piping Date due: 15- YEAR TESTING I. Was the 5 year testing performed on the following items? A. Sprinkler heads in corrosive environments or rated 325" F or higher. B. Standard sprinklers in service for 75+ years. y N N/A \ Date Due: Date Due: y N N/A Date Due: '\. Date Due: Date Due: 110-YEAR TESTING I. Was the ] 0 year testing performed on the following items? A. Standard sprinklers in service for 50+ years. B. Quick response sprinklers in service for 20+ years. C. Dry pendant sprinklers. This document PROPERTY OF AHERN FIRE PROTECTION. Copyright 2005 JF Ahern Co. REPRODUCTIONS IN ANY FORM VIOLATES COPYRIGHT rptlnspection _Annual LID #:""3150135 ICONTROL VALVE SERVICE I. Were the following service items performed on all control valves? A. Fully opened and closed? B. Valve packing checked? C. Valve stem lubricated? D. Is the valve properly secured and locked in it's normal operating position? Page 2 of 3 -- Y N N/A ~ '\ ~ BACKFLOW PREVENTOR TEST I. Did the backflow preventor(s) pass the test of back flow and forward flow capabilities? Y N ANTI-FREEZE TEST Y N I. Has the anti-freeze solution for each system below been tested by measuring specific gravity? IHANGERS AND SEISMIC BRACING I. Did hangers and seismic bracing appear to be in good condition, firmly attached, and free from corrosion, from a visual inspection } performed from floor level? .,' )0'" Y N N/A PIPING I. Was the exterior of exposed sprinkler piping in good condition, not subjected to external loads. free of mechanical damage? NOTE: Piping located in concealed spaces, such as above a drop ceiling. are not required to be inspected. IFIRE DEPARTMENT CONNECTIONS I. Are fire department connections visible and in good condition? 2. Are caps and plugs in place? 3. Are automatic drain valves operating properly? 4. Do hose connections operate freely? Y N N/A ~ \ HOSE RACKS PRESENT? Yes No CONDITION: Good Fair Bad MAIN DRAIN TEST System Number Static Pressure Residual Pressure Size of drain we1.-- l i 7" -- ~."'~ !. //? 1.../! " I rJ'- :'~ \{-" . . <i.:./,;iL _____ ,. r .. ~..., I. Were all main drains tested at full flow? If no. explain: 2. Were test results similar to the last test? Ifno. explain: 3. Was there any discharge of obstructive material, heavy discoloration of water. or plugging of the inspector's test connection? GENERAL INFORMATION \ \ Y ~ ~ \ \ \ ~ \ Y N N/A I ~ I. Are all the spiinkler systems in service? 2. Is the building completely sprinklered? 3. Are all sprinklers in good condition? 4. Are all sprinklers free of obstruction? 5. Are spare sprinklers and wrenches available? 6. In spray coating area. are sprinklers free from accumulation? 7. Is hydraulic nameplate and information sign securely in place and legible? 8. Is emergency service contact information readily available? 9. Are alarm devices provided and in good condition? 10. Are all standard sprinklers dated 1920 or later? IOWNER QUESTIONS I. Any changes in sprinkler system since last inspection? 2. Any fires since last inspection? This document PROPERTY OF AHERN FIRE PROTECTION Copyright 2005 JF. Ahern Co REPRODUCTIONS IN ANY FORM VIOLATES COPYRIGHT rptlnspection _ Annual Do if '3150135 A. Number of sprinkler heads that operated. B. How long was system out of service? C. Area where fire occured. 3. Are all areas of the building properly heated to prevent freezing where wet pipe systems exist? 4. Do you have an outside alarm service? If yes. name and phone number. Page 3 of 3 , Owner/Representative's Signature: ---::; (i/ ,/Lr /,/ Date I _ (, - New Deficiencies found during this inspection? I Yes' No ~ Customer receive copy of New Deficiency Report? Yes\No A previous inspection for your facility revealed the following deficiency in your Fire Protection System: ..... . f1' " A ,- ( Quote: Quantity: Def Date: 5/21/2008 Def#: 3150596 System # ( Ii Painted head on 2nd floor elevator lobby, also missing white plate IF THIS DEFICIENCY HAS BEEN REPAIRED. PLEASE FILL IN DATE OF REPAIR: FOREMAN'S INITIALS: AHERN FIRE PROTECTION will perform this repair per your verbal or written approval. Should you elect to proceed with this work, please call or sign and fax or mail a copy of this page. We will call to set up an appointment. Thank you. ACCEPTED BY: DATE: A previous inspection for your facility revealed the following deficiency in your Fire Protection System: Def Date: 5/21/2008 Def#: 3150597 System # Quote: Quantity: Tape and paper covering line piping and heads right outside elevator lobby in garage level <. rt . c IF THIS DEFICIENCY HAS BEEN REPAIRED. PLEASE FILL IN DATE OF REPAIR: FOREMAN'S INITIALS -..,.- r' AHERN FIRE PROTECTION will perform this repair per your verbal or written approval. Should you elect to proceed with this work. please call of sign and fax or mail a copy of this page. We will call to set up an appointment. Thank you. ACCEPTED BY: DATE: A previous inspection for your facility revealed the following deficiency in your Fire Protection System: Def Date: 5/21/2008 Def#: 3150598 System # Quote: Quantity: No inspectors port to test water flow for standpipe feed. Had to test manually this year. Could not simulate waterflow. IF THIS DEFICIENCY HAS BEEN REPAIRED. PLEASE FILL IN DATE OF REPAIR: FOREMAN'S INITIALS: AHERN FIRE PROTECTION will perform this repair per your verbal or written approval. Should you elect to proceed with this work. please call or sign and fax or mail a copy of this page. We will call to set up an appointment. Thank you. ACCEPTED BY: DATE: A previous inspection for your facility revealed the following deficiency in your Fire Protection System: Def Date: 5/21/2008 Def # 31505~?__ System # r- _----___ Quote: .Y--'--'--'-'----- --- ------~---..-__ Quantity: ~-';;,/- ,\< --..- \ . Need to add I head in each stairwell on garage level to cover under stairs. On same level standpipe hose connections point clirectiYmto a wall making It dJthculfro-ll~ok liji~e-turned and adjusted so fire department can attach IF THIS DEFICIENCY HAS BEEN REPAIRED. PLEASE FILL IN DATE OF REPAIR: FOREMAN'S INITIALS: AHERN FIRE PROTECTION will perform this repair per your verbal or written approval. Should you elect to proceed with this work. please call or sign and fax or mail a copy of this page. We will call to set up an appointment. Thank you. ACCEPTED BY: DATE: INOTES " ,. l- SERVICES PERFORMED: Alarm Test Drain Test Flow Test Walk Through f Annual Inspection REPRODUCTIONS IN ANY FORM VIOLATES COPYRIGHT Other This document PROPERTY OF AHERN FIRE PROTECTION. Copyright 2005 JF Ahern Co rptlnspection _Annual