HomeMy WebLinkAboutReport of Inspection 6/17/2009 SUMMIT ~ PROTECTION 575 MINNEHAHA AVE. W. ST. PAUL, MN 55103. (651) 251-1880 3026 40TH AVE. NW. ROCHESTER, MN 55901. (507) 280-0622 418 GREAT OAK DR., WAITE PARK, MN 56387 · (320) 257-6390 7(fJ LIBElITYWAY, NORTH LffiERTY, IA 52317. (319) 665-4330 4208 ENTERPRISE CIRCLE. DULUTH, MN 55811 . (218) 740-4412 SHEET 1 OF 2 - Use separate sheet for each building inspection REPORT OF INSPECTION JOB NUMBER 7 '1 :3 Lt( BunDINGILOCATION INSPECTOR ::::::t) t~-C;--JK(Jc. 1\ DATE G' 17 -Of! MINNESOTA LICENSE NO. COO75 INSPECTION NAME STREET CITY & STATE Owner's Section (to be answered by Owner or Occupant) A. Explain any occupancy hazard changes since the previous inspection: B. Describe fire protection modifications made since last inspection: (/i ;, / /1 .':..... -J. , C. Describe any fires since last inspection: D. When was the system piping last checked for stoppage, corrosion offoreign material? E. When was the dry-piping system last checked for proper pitch? F. Are dry valves adequately protected from freezing? Signature Title Date 1;, /7. ny Inspector's Section (AU responses reference current inspection) 1. General , a. Is the building occupied? I5LYes D No b. Are all systems in service? -~Yes D No c. Is there a minimum of 18 in. (457 rom) clearance between the top of the storage and the sprinkler deflectors? DYes~o d. Does all electrical heat tape appear to be satisfactory? DYes D No )d NA e. Does the hand hose or standpipe on the sprinkler system(s) appear to be satisfactory? DYes D No br'NA 2. Control Valves (See Item 15.) . a. Are all sprinkler system control valves and all other valves in the appropriate open or closed pqsition? i(Yes D No b. Are all control valves in the open position locked, sealed or equipped with a tamper switch? E1Yes D No 3. Tanks, Pumps, Fire Department Connections- . a. When was fire pump last tested for performance? ....... b. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? DYes D No.NA c. Are fire department connection~_ satisfactory condition, couplings free, caps in place, and check valves tight? 9(,Yes D No D NA Are they accessible and visible? JJl'Yes D No DNA 4. Wet Systems a. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position? DYes D No j(NA b. Have antifreeze system solutions been tested? DYes D No O'<NA c. What temp is antifreeze? - d. In areas protected !>y wet system(s), does the building appear to be properly heated in all areas, including blind attics and perimeter areas where accessible? ~es D No D NA 5. Dry System (See Items Il to 13) a. Are dry valve(s) in service? DYes D No A b. Are the air pressures and priming water 1 els in accordance with the manufacturer's instructions? DYes D No D NA c. Has the operation of the air or nitroge upplies been tested? DYes D No D NA Are they in service? DYes D No D NA d. Were low points drained during thi 'nspection? DYes D No D NA How many? e. Did quick-opening devices oper satisfactorily? DYes D No D NA f. Did the dry valve(s) trip pro y during the trip pressure test? DYes D No D NA g. Did the heating equipment' the dry-pipe valv7l'OOm(s) operate at time of inspection? DYes D No D NA 6. Special Systems (See Item 14.) ,,/ a. Did the deluge or pre-action valves ope e properly during testing? DYes D No D NA b. Did the heat-responsive devices ope e properly during testing? DYes D No DNA c. Did supervisory devices operate d 'ng testing? DYes D No DNA d. Did flow for kitchen hood syst shut off gas or electric? DYes D No D NA 7. Alarms a. Did water motor(s) and gong(s) test satisfactorily? DYes D No!3.NA b. Did electric alarm(s) test satisfactorily? til)'es D No D NA c. Did supervisory alarm service test satisfactorily? lJ(Yes D No . D NA d. Did tamper switches test satisfactorily? l:lIYes D No D NA 8. Sprinklers a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge? DYes JAJ'l0 b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) )jiYes DNo c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testing) JijYes D No d. Is stock of spare sprinklers available?G4Yes D No e. Does the exterior condition of sprinkler system appear to be satisfactory? !;;IYes D No f. Are sprinkler~er temperature rating for their locations? CJYes D No g. Are any s~er, I).eaia~ec)dllist? DYes !:):No i J 'If:; , . , t ., ' S. . ~",,-' f'!' j 1- ~-" D I Ignature. , :y' \ t vli\~ '-' ate: \) ,-----r: i ----:- ~ l, NA =NOT APPLICABLE 709 I SUMMIT FIRE.PROTECTION "A__! \1;'<.0 1 575 MINNEHAHA AVE. W. ST. PAUL, MN 55103. (651) 251~1880 3026 40TH AVE. NW. ROCHESTER, MN 55901. (507) 280-0622 418 GREAT OAK DR, WAITE PARK, MN 56387 · (320) 257-6390 760 LffiERTY WAY, NORTH LIBERTY, IA 52317 · (319) 665-4330 4208 ENTERPRISE CIRCLE. DULUTH,MN 55811 . (218) 740-4412 SHEET :2 OF 2 - Use separate sheet for eachsystem inspection In~tion Nam. e and Nu;nl>er '. 793 t-f, 'c"l "", \v'; J...-t A t~r I - Type of System ,Ale.).... How Many? I ~~~. 1.-1 I! (' /"PIow SWitch or -=> ' ,-,~th Pressure Switch 9. Date dry-pipe valve trip tested (control valve partially open) 10. I>ate dry-pipe valve trip tested (control valve fully open) 11; Date / (See Trip Test Table which follows) -1See Trip Test Table which follows) / 12. Date quick-opening device tested . (See Trip Test ,r;t;;which follows) DRY VALVE TRIP TEST LE 0.0.0. MAKE MODEL T SERIAL NO. .J" MAKE I MODEL SERIAL NO. 71 I DRY PIPE Time to Trip Water // Air Tri~ Point Time Water Reached Alarm Operated OPERATING Thill Test Pipe Pressure /' pressure Air ressura Test Outlet Property TEST MIN. SEC. PSI PSI PSI MIN, SEC. YES NO Without .// 0.0.0. WIlh ,- 0.0.0. f ./ deluge or preaction valve tested (See Trifl/Test Table which follows) TRIP TESt TABLE Operation o PNEUMATIC o ELECTRJe o HYDRAULIC Piping Supervised DYES o NO/ Dete<;ting media supervised DYES o NO DELUGE & Does valve operate from the menual trip andIQf ~ control stations DYES o NO PREACTION Is there an accessible facility in each clrcu~esting Method of testing-clrcuits VAlVES DYES 0 / Does each circuit operate Does each circuit Maximum time to MAKE MO,9El s"""rvislon Joss alarm I """rate valve ralaase ooerate release / YES I NO YES I NO YES I NO I I ontrol Valve Maintenance Table. Control Valve Maintenance Table 13. See C Explain Abnormal Control. Valves Number Type Open Secured Closed Signs Condition City Connection Control Valve Tank Control Valves Pump Control Valves Sectional Control Valves System Control Valves J _ II II ('')c,t-. V '1,.-"., V?-o. i/ Ij '))<... Other Control Valves / / "-' ,I I Kitchen Control Valve 16. Water Flow Test at Sprinkler Riser Water Supply Source: Date City Test Pipe Location Tank Static Pressure Differential Size of Test Pipe Last Water Flow Test This Water Flow Test 14. Explain any "No" answers and comments: /<'~) \....... c.} , I 0 ''''' ,-" '::.J~ -.r, ~)~~ . . "J .1 .~ \~ .,;< (A)\f...') ( ;J q ~)q ) c.?;; --I ...... ('\ r "0 /1 J . >l'r~l. r iO .1.- (," ''<''"(,.~ ....' - I.t Sac L ~ / r7 ,/ .~..'~:-'~ ~~....L t'~~-""'t"?rl /'\/(,/'v'-< i....o /f l,../ ______..,;~ __ \ '''0 \" ..-."0,.,,,/1 Date: C I J 0 0/ Signature: