HomeMy WebLinkAboutFire Alarm Report 10/21/2009 Metro Alarm "We Save Lives & Protect Property" P.o. BOX 1775 . BURNSVILLE, MN 55337 · SERVICE (952) 890-6684 · FAX (952) 707-6881 · LIC#TS00401 Iii:'\ www.metroalarmco.com ~ Underwriters Laboratories Inc. @ ALARM SERVICE #S8526-1 FIRE ALARM INSPECTION AND TEST REPORT I COpy TO:_CLIENT_FIRE DEPT. I ACCT. NO tI C./~ 71 c:: 7 SERVICE CALL NO. LJ7ifz q U.L. CERTIFICATE NO.' '. DATE Jo. L /- CUSTOMER::' . La k '" Pnlt,.. p CI;. /,,,,... CONTACT -P;" In JL /- / ~"'tt:: TITLE ADDRESS LJb 'Jq Ilntofl? St<(F PHONE 9.'il- tfllQ- 3SSS" I_BI-MONTHLY _SEMI-ANNUAL CITY n LAx' MONTHLY ;!ANNUAL STATE HAl I ZIP 553 77 I QUARTERLY FINAL CONTROL PANEL MANUFACTURE or .1. .J. J. . l~ODEL NO. 5111 () XL LOCATION bt:1141'U Mer J. / Elp/ R,..,. TYPE OF SIGNALING v POWER CIR. BRK#.'LOCATION NO. LOCKED CIR BRKR. DEDICATED CIR XGENERALALARM _SELECTIVE SIGNALS _CODED _PRE-SIGNAL SOURCE _YES _NO _YES _NO BATTERIES VOLT WITH CHllrollR. _" ~F~ TROUBLE RESPONSE TO ZONE TROUBLE SIGNAL TROUBLE AClOP POWER LOSS EARTH GROUND VOLT WITHOu l~GER ^ Iff../ /. NEW CONDITIONS NORMAL NOTE NORMAL NOTE NORMAL NOTE NORMAL NOTE COMMUNICATOR ," . , " , .'~' .' , , MANUFACTURE <: A ,AI ,.... -4 MODEL NO. LOCATION ."5 AMP "71 BATTERIES VOLT WITH C VRGllR NOTE # POWER CIR. BRKR.rIdN NO. LOCKED CIR BRKR. DEDICATED CIR VOLT WITHO~h CHARGER NEW SOURCE YES NO YES NO CENTRAL MONITORING RESPONSE TO ALARM TROUBLE RESPONSE TO ZONE TROUBLE SIGNAL TROUBLE AC/OP POWER LOSS EARTH GROUND STATION )NORM. NOTE # CONDITIONS )lNORMAL NOTE jNORMAL NOTE )::NORMAL _NOTE _NORMAL NOTE COMMUNICATOR PRIMARY # 152 ~ lfl.-17- 521.(7 COMMUNICATORSECONDARY# rSl- '111 0.... 3bt~ AUXILIARY FUNCTIONS ANNUNCIATO~l::G) 1'1. . ,~rl MODEL TYPE _INCAD _GRAPHIC _CRT) I VOLTAGE, D"- I NO jZONES I UNUSED PTS. 5, ,f.. A LED DROP A,.CD 7. l{ c/ 3 ELEVATOR RECAL~ TO PRIMARY FLOOR I RECALL TO ALTERNATE FLOOR ELEVATOR RESTART FIRE RECALL XJo;ORMAL NOTE N/A )(NORMAL NOTE N/A FROM FIRE SUC. AUTOMATICALLY YES )!:.NO SPRINKLER SYSTEM: METRO ALARM'S INSPECTIo;; ;NL Y INCLUDES A FUNCTIONAL 7;:' "I jla C( ACTUAL FIRE SPRINKLER TEST WAS DONE BY: f'OI'JA./..:):-' k. .r' TESTED: PERIPHERAL FUNCTION TEST DEVICE [t IUl ()In U FLOOR VOLTS MFG & MODEL # NOTE Manual Stations R of R Heat Detectors 1/ 1.. 24111)( 5)p..t Jr-LO~ Fixed Heat Detectors IY Photo Smoke 1/. II Z "IvDt' .Tn sosyfPS , . Ion Smoke Duct Smoke 2. 2'1.;Ot _sn .t;t?S-AP/JP Waterflow I <. ,1_ 54?~ GVT I IL 11", tlv PIV Y 5 J. < -- Low Air Horns Only --r Strobes Only 3 6 I 2 LJ. nl L Ii ~- I4Ie-k Horn I Strobes q 'I I Z L/VJ}/ \ill ,p e loci' Speaker I Strobes Door Holders NOTATIONS AND COMMENTS . .. ! 1 "'it A / J J;.~ f~~J Gc?r/)d . - / j , CUSTOMER SIGNATURE: SERVICE REP SIGNATU_V& L- ~". .--' 7_ .i' /