Loading...
HomeMy WebLinkAbout01-46 PRELIMINARY PLAT RESOLUTION 01-46 RESOLUTION OF THE PRIOR LAKE CITY COUNCIL APPROVING THE PRELIMINARY PLAT OF "REGAL CREST" SUBJECT TO THE CONDITIONS OUTLINED HEREIN. MOTION BY: ZIESKA SECOND BY: PETERSEN WHEREAS: The Prior Lake Planning Commission conducted a public hearing on February 12, 2001, to consider an application from Pavek Family Investments and Hodgson Trust for a Preliminary Plat for to be known as Regal Crest; and WHEREAS, The Prior Lake Planning Commission continued the public hearing to March 26, 2001; and WHEREAS: Notice of the public hearing on said preliminary plat has been duly published and posted in accordance with the applicable Minnesota Statutes and Prior Lake Ordinances; and WHEREAS: All persons interested in this issue were afforded the opportunity to present their views and objections related to the preliminary plat of Regal Crest for the record at the public hearing conducted by the Planning Commission; and WHEREAS: The Planning Commission and City Council have reviewed the preliminary plat according to the applicable provisions of the Prior Lake Zoning and Subdivision Ordinances and found said preliminary plat to be consistent with the provisions of said ordinances; and WHEREAS The Prior Lake City Council considered an application for preliminary plat approval of Regal Crest on April 16, 2001; and WHEREAS: The City Council finds the preliminary plat of Regal Crest to be consistent with the 2020 Comprehensive Plan. NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY OF PRIOR LAKE, MINNESOTA: A. The above recitals are incorporated herein as if fully set forth. B. The preliminary plat of Regal Crest is approved subject to the following conditions: 1) The plans should be revised to combine more of the driveway openings, especially on Jeffers Pass. 2) Address the following comments from the City Engineer: a) Submit a wetland replacement application. rt~0~,~u~'~l~)~:~J~.o, Cprior Lake, Minnesota 55372-1714 / Ph. (612) 447-4230 F)'a~t~xl(612) 447-4245 AN EQUAL OPPORTUNITY EMPLOYER b) Provide an additional Iow point on Jeffers Pass, north of Thatcher Lane, to direct runoff into the southwest wetland on the property. c) Maximum slope of grading in maintained areas is 4:1. Some graded areas are shown with a greater than 3:1 slope. Provide retaining walls as necessary to create 4:1 slopes in maintained areas. d) Refer to the Prior Lake Design Manual for preparation of plans and specifications. e) Look at alternative ways of connecting to the existing sanitary sewer. f) Catch basin 15 is located in a driveway. The driveway location must be moved. g) The intersection of Lauren Lane and Jeffers Pass must be constructed in Phase 1 to eliminate the need for a temporary cul-de-sac. h) The developer must obtain temporary construction easements where off-site grading is occurring. These easements must be provided to the City prior to issuance of a grading permit. i) The street grade shall not exceed 2.00% for the first 100' approaching the intersection with C.R. 21. 3) Address the following comments from the Scott County Engineer: a) Provide a right-turn lane, designed to County standards, on CSAH 21 at Jeffers Pass. b) Remove the existing driveway on CSAH 21 and grade to match right-of-way. c) Obtain permits from the County for any work in the County right-of-way. 4) Obtain a permit from the Watershed District. 5) All necessary permits from other agencies must be obtained and submitted to the City prior to final plat approval, or prior to approval of a grading permit. Passed and adopted this 16t" day of April, 2001. YES NO Mader X Mader Gundlach X Gundlach Ericson X Ericson Petersen X Petersen Zieska X Zieska ~ {Seal} Frank Bo~y M~nager r:\resoluti\planres\2001 \01-46.doc Page 2