Loading...
HomeMy WebLinkAboutReport of Inspection 3/12/2010 Report of InspectionlTest Annual Wet March 11,2010 Property Owner/Agent Prior Lake Maintenance Bldg. ~AUTCWAT~SPRHtJS~ t 10351 JamesloVtTl 81. NE . Blaine, MN 55449 Tel (763) 784-8002 Fax (763) 784-5797 Conducted by: Joel Hirsch Inapection Ref: 11899 Owner. Printed City of Prior Lake I Owner. Signature 3111110 12:00 am td. 3111110 12:00 am ~ 3111/10 12:00 am I state that the infori'n8tlon on INs form Ia'coritct at the time and DIace of my Inllrl8c11on. and alt equ.ent tested at this time was teft in operallonal COniIIlIon upon comoletlon of this lnaoecllon ".....Ias noted. I acknow~ this reP<!rt has been revIelVed with me. Exc!!pt as noted. the... have been no changes to the orlairial aDOroved system. Owner. Cefic . Printed City of Prior Lake Owner- ~fic - "nature This acknowled~s notlllcltlonof d~1n lhe system. These CleflClencles could endanaer clllty ~ants. Thisacknowledg,' ,lis nor an authOrIzation to reDair these deficiencies. System Off System On Monitoring Company Metro Alarm (952)346-9452 Operator USA Central Alarm PaneflCode SK 5207 451.1318 Gauges on wet pipe system in good condition and showing normal water supply pressure? Alarm devices free from physical damage? Hydraulic nameplate. if provided. securely attached to riser and legible? Valve su iso switches indicate movement? Yes Yes Yes Yes Yes Yes Yes NA NA Visible and accessible? Couplings and swivels' not damaged and rotate smoothly? Plugs or caps in place and undamaged? Gaskets in place and in good condition? Identification sign(s) in place? Check valve is not leaking? Automatic drain valve in place and operating properly? Interior free of obstruct.ions (if caps are not in place) ? Valve cia r 0 erati at over its full ran if . are not in NA Alarm valves and their associated strainers, filters and restriction orifices passed internal inspection? Check valves internally inspected and all parts operate properly. move freely and are in good condition? Strainers, filters, restricted orifices and diaphragm chambers on dry pipe, preaction and deluge valves passed internal inspection? Gauges checked against calibrated gauge or replaced? No NA Yes Print 3/1212010 (All "NO" answers a18 to be fully explained.) CopyrIght 2002-2009 life Safety Intpedor. OnSlte Software. Inc. P...1of3 Report of Inspectiol1/Test Annual Wet March 11, 2010 Property: Prior Lake Maintenance Bldg. Owner: ~AIJTQMA11CSPlINKLEftCo. " Inspection Ref: 11899 I n good condition ? Free of mechanical damage and not leaking? No external corrosion? Properly aligned ? No extemalloads ? Visible' h ers and seismic braces not Yes Sprinkler wrench with spare sprinklers? Yes Proper number and type of spare sprinklers? Yes Free of corrosiOn? Yes Free of obstructiOns to spray patterns? Yes Free of foreign materials including paint? Yes Free of phySical damate? Yes Are all spriAklers in se""ice dated 1920 or 1ater? Yes Fast Response Sprinklers in service for less than 20 years? If "no. test sample now and every 10 years. Yes Standard sprinklers Ie8s than 50 years okI? If no test sample now and every 10 years. No If sprinklers have been replaced, were they proper replacements? 1 recalled sprinkler . foe Lube Stbnige. NA Sprinklers and spray noZZles protecting commercial cooking equipment and ventilating systems re laced ex for bulb- which show no sins ofse build 1 Connection Outlet P.....ur. (PSI) Alanna W......ow .Reeults System Flowed Size Actuate devices comparable Static Reskl Static pass test toPl'tor test Main Main drain 2 101 72 80 NA NA Yes ITV on riser & se Inspector's test 1/2 Yes Yes Yes comer of Qara e Description .. .~ ~! I jJ 'S~ Type Secured c I .:: en & sl 0 enl 0 rn c .3 1 Os&Y 4" Supervised Yes Yes Yes Yes Yes 1 Post Indicator 6" Pad Locked Yes Yes Yes Yes NA Control Valve ChartllnsplMaint Control Valve Chartllnsp/Maint Print 3/1212010 (All "NO" answers are to be fully explained.) Copyright 2002.2009 life Saftty Inspector. OnSite Sotlwa.... Inc. p... 2 of 3 Report of InspectionlTest Annual Wet March 11,2010 ProPftrty: Prior Lake Maintenance Bldg. Owner: ~~nCSMNKL!RCCl t Inspection Ref: 11899 I Deftciency Summary These items were deficient and do not meet the requirements of the applicable code at the time of tie inspection. Items marked Recommendation are not required by the applicable code but are opportunities to improve the Life Safety of the property. No Check valves Internally Inspected and aU pa.... operate properly ,move freely and are in good condition? NFPA-25-2002 12.4.2.1 Valves shall be inspected internally eve/)' 5 years to verify that all components operate properly, move freely, and are in good condition. No If sprinklers have been replaced, were they proper replacements? 1 recalled sprinkler @ 108 Lube Stofllge. NFPA-25.2002 5.4.1.1 Replacement Sprinklers shall have the proper characteristics for the application intended. Print 3/1212010 (All "NO" answers ate to be fully explained.) Copyright 2Q02.2009l.1f1t Stftty I '" ,..or, 0nSite Software, Inc. Page 3 of 3