HomeMy WebLinkAboutReport of Inspection 3/12/2010Report i~f Inspection/Test
Annual ~ ~~~ t+~~ Nrrar+mct:ar:itrlct.~itco. ~l
March 12, 2010 10351 Jamestown St. NE - Blaa~e, MN 55449•
Property thlmer/Agent Td (763} 784-8902 Fax (763} 784-5787
Conducted by: Joel Hirsch
Ittuepectfon Reh 13003
Bob Htatcttins
Inspector -Printed
Joel Hirsch tnspeacr - 5tprtatut~e f t state that the ktilomr~fon on this tam b correct at the
t&rre and of my Mspucuon, and aU equipment
3/1?J10 tested at the tlme was Iett ~ operatlonsi melon upon
12'tf0 a~n comctetion of this insaedion e3ooaot as noted.
Owner -Printed er - nature ' ' t ~krwwledps this report has been reviewed wkh me.
Gity of Prior Lake ~M 2/10 ail oGroved s~vsrotom ~ been no charges to the
12:A0 arm
Owner - t5C - Printed ~ - c - na re 11Ms rtoaAc~tion ct detkisrxies ~ the
City of Prior Lake system. ??rase delidendes could end facility
3/1?J10 occt
ants
This
dcnowled
nt i
m
ao~a
~
.
s
pe
e
s n
n
authorizatlon to re
alr thes
d
n
i
fl
i
e
a
e
C
e
c
ea.
12.`00 arttl
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Na
NA
NA
Yes
Yes
Yes
Yes
Yes
NA
NA
Gauges on wet pipe system 'in good condition and showing normal water supply pressure?
Alarm devices free from physical damage?
Hydraulic nameplate, if provided, secxtrey attached to riser and legible?
Visible and acxessible?
Couplings and swivels not damaged and rotate smoothly?
Plugs or daps in piece. find undamaged?
Gaskets in place and in good condition?
identification signs} in place?
Check vahee is not ing?
Automatic dra#, valve ~ pt~e and operating properly?
Auto drain ifNird vse'~csliy, t ire hot~tl to fut~t P~PeHY•
lrrterior fratr of ot~structlor~ (lf csptt aria not ~ piarce> ?
Valve clapper operational-over i~ fret r6ii~s (if caDS are not in
. ~_,_ _
Free of ntechanicai damage anti not leaking ?
No extetna4 corrosion ?
Prnp+~ly a~ned ?
No external Marls ?
VisibM pipe hangars and seismic braces trot damaged or loose ?
Was an obstnx~at rove ocriducted si~d the system flushed ?
very extra htgitand tam ttigh ten~et'e spektkbrs tested ?
Print 3/15/2010 (All "11117"answers are to be ftdly explained.) Peg! 1 of 5
C~yripht 2002-2009 t.ite Safety Inspector, OnSke Software, Inc.
Report of Inspection/Test ~ ~~~~~~ ~~
~~aura~aanc si+fstiu~t co:
Annual
March 12, 2010
Property: Prior Lake Water Treatment
f~vtfrtisn': Inspection Ref: 13003
Yes Sprinkler wrench with apace sprinklers?
Yes Proper number and type of spare sprinklers?
Yes Free of corrosion?
No Free of obt~tructions to spray patterns?
No sprink~r ~ janitor closet.
Yes Free of foreign materials including paint?
Yes Free of physical damage?
Yes Are all sprinklers in service dated 1920 or later?
Yes Fast Response sprinklers in service for less than 20 years? If "no" test sample now and every
10 years.
Yes Standard sprinklers less than 50 years dd ? If no test sample now and every 10 years.
Yes If sprinklers have been raptaced, wpere they proper replacemertts?
NA Sprinklers and spray nozzles pi~otef~tig cornrrtiercial cooking equipment and ventilating. systems
replaced except for bulb-type which show no signs of grease buildup?
NA Adequate heat in areas with wet piping?
NA Interior of pipe in preaction and dry pipe systems which passes through freezers free of ice
blockage?
Yes Auxiliary drains drained in dry pipe, prearXion and deluge systems prior to the onset of freezing
weather?
Drip ene on systsert roquiros a 1 1!4" CHECK valve, not a ball valve.
Yes Enclosures around dry-pie, preaction or deluge valves maintaining a minimum of 40° F?
Yes Gauges on dry, preaction and deluge systems in good condition and showing normal air and
water pressure?
Yes Free from physical damage?
Yes Trim valves in appropriate {open or dosed) position?
Yes No leakage from intermediate chamber?
Yes Interior of dry pipe, preaction and deluge valves passed intemal inspection (required every 5th
year if resalable withotat opening)?
Yes Priming water level correct?
Yes Low air pressure signet passed test?
NA Quick opening devices passed test?
Yes Automatic air maintenance devices on dry pipe and preaction systems passed test?
Yes Dry pipe systems being ttiafirttained in dry condition?
Yes Interior of drv pipe. praadion arks delve vahras,daaned?
NA Alarm valves and their'assofiated strainers, fitters and tBStrtdian orifices passed intemal
inspection?
NA Check valves intemaNy inspected antl all puts operate properiy,move freely and are in good
condition?
NA Strainers, liters, restricted orifices and diaphragm chambers on dry pipe, preaction and deluge
valves passed intemal inspection?
NA Gauges checked against calibrated gauge ar replaced ?
Print 3/15/2010 (All "NO"answers er+s to i'9e fully explained.)
Copyright 2002-3009 Lib Seflty inspector, OnSite Software, Inc.
Pape 2 of S
Report of Inspalllction/'test
Annual
March 12, 2010
Property: Prior Lake Water Treatment
IDwner:
~~~~' ~Y I~f.G~i V~ f
Inspection Ref: 13003
C Aire Manufacturer of compressor
s175t Model of compressor
Size of compressor (HP)
Horizontal Compressor C)eacxiptioNType
Yes Compressor appears ~ be in working condoion?
Yes Compressor appears free of leaks?
Yes Compressor and motor acre free of vibralition and unusual noies?
Yes Guaalges appear Ok a3nd show rtonnal PSI
Yes Oil appears dean with rw twmt odor
Yes Electrical cont>eetions ?
Yes Breaker in the ON Pa~tion?
Yes inlet air filter clean?
Yes Bek is in geed condition?
Yes Tens~rt on the tit is C~k?
Yes Has condensalrater baearn drained Pram tlu tank and/or water separator?
Print 3/15/2fl10 (Al! "NO" answ~rrs are to be fully explained.) Pale 3 of 5
Copyright 2Q02-2009 Late StNty Insps~.tor, Onsi~ Sollware, Inc.
Report of InspectionlTest
Annual
March 12, 2010
Property: Prior Lake Water Treatment
Owner:
~~~~~j~~ ..~~ ~ u~v-ncsaarol~cctx
I~
Inspection Ref: 13003
Print 3/15/2010 (All "NO"answers are to be fully explained.) Pale 4 of 5
Copyright 2002-2009 Life Sa>;ety Inspector, OnSka 3o11ware, Inc.
Comparable to previous tests ? NA
Report of Inspection/Test
Annual
March 12, 2010
Properly: Prior Lake Water Treatment
t)vvner:
Deficiency
1~~~~ ~ ~~ ~ A~IYOIilAT1C 9pNtNKEE~t Ott,
~~
Inspectia~ Ref: 13003
These items were deficient and do not meet the requirements of the applicable code at the time of the inspection.
Items marked Recom-nendation are not reQuired by the applicable code but are opportunities to improve the Life
Safety of the property.
No Automstlc drain valve in place and operatic properly?
PNnt 3/15/2010 (All "NO"answers are to be fully explained.) Page S of 5
copy~~ zooz-2ooe ure Uspecta, t~n3iis sdlware, inc.