HomeMy WebLinkAbout00-68 PRELIMINARY PLAT
RESOLUTION 00-68
RESOLUTION OF THE PRIOR LAKE CITY COUNCIL APPROVING THE PRELIMINARY PLAT OF
"THE WILDS 5TH ADDITION" SUBJECT TO THE CONDITIONS OUTLINED HEREIN.
MOTION BY: Mader SECOND BY: Petersen
WHEREAS: the Prior Lake Planning Commission conducted a public hearing on July 10, 2000 to
consider an application from Shamrock Development, Inc., for the preliminary plat of
The Wilds 5th Addition; and
WHEREAS: notice of the public hearing on said preliminary plat has been duly published and posted
in accordance with the applicable Minnesota Statutes and Prior Lake Ordinances; and
WHEREAS: all persons interested in this issue were afforded the opportunity to present their views
and objections related to the preliminary plat of The Wilds 5th Addition for the record at
the Planning Commission hearing; and
WHEREAS: the Planning Commission and City Council have reviewed the preliminary plat according
to the applicable provisions of the Prior Lake Zoning and Subdivision Ordinances and
found said preliminary plat to be consistent with the provisions of said ordinances; and
WHEREAS the Prior Lake City Council considered an application for preliminary plat approval of
The Wilds 5th Addition on August 7, 2000; and
WHEREAS: the City Council finds the preliminary plat of The Wilds 5th Addition to be consistent with
the 2020 Comprehensive Plan.
NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY OF PRIOR
LAKE, MINNESOTA:
A. The above recitals are incorporated herein as if fully set forth.
B. The preliminary plat of The Wilds 5th Addition is approved subject to the following conditions:
1) The lot areas above the 100 year flood elevation need to be determined for those lots abutting
the ponds and wetlands and must meet the minimum requirements of the zoning ordinance.
2) The following comments of the Engineering Department need to be reflected in the approved
preliminary plat.
a) The drainage calculations for Pond 3 (existing conditions) assume a broad-crested weir with
an overflow elevation of 938.0. The Wilds grading plan show that the overflow elevation is
around 941 or higher. The bituminous path on Wilds Parkway will be the control elevation
for this pond. The calculations need to reflect this.
b) For the existing conditions, the Pond 2 outlet should act as a V-shaped broad crested weir
with a Iow point of 945.6, 25 feet long, with the end elevations at 946.0.
16200 Eaqle Cr,~l~ Av~ .q F Prior Lake, Minnesota 55372-1714 / Ph. (612) 447-4230 ~'age '~
r:xreso~uml:nanre~.Z00.0~OO_68.-d6c ~ Fax.(612) 447-4245
AN EQUAL OPPORTUNITY EMPLOYER
c) Proposed Subcatchment 9 should be split into 2 areas, such as existing conditions.
d) It appears, as it's designed, that Pond 4 will overflow into Pond 3 during a 100 year event.
The piping should be configured so Pond 4 discharges into Pond 3, and Pond 3 discharges
into the existing pipe network.
e) Two (2) alternatives need to be provided to avoid the wetland impacts per WCA
(Sequencing 8420.0520) for this project.
f) There are still 2.72 acres of wetland mitigation required as part of the original "Wilds"
development. A wetland replacement plan should be submitted outlining how the 2.72
acres of wetland mitigation will be created. This mitigation needs to occur concurrently with
this project before any further wetlands are impacted due to filling.
g) Lot 6, Block 3 does not meet the 30' setback for the HWL.
h) Lot 5, Block 1 is not 3' above the HWL.
i) Provide a 2' freeboard above the emergency overflow elevation and the Iow floor of homes
adjacent to backyard catchbasins. This applies to Lot 3, Block 2 and Lots 11, 12 & 13 of
Block 3.
j) The impervious fraction for Pond 2 in the PONDSIZ spreadsheet should be raised to 0.3
(30%) impervious fraction for Subcatchment 4.
k) Add City Project #41-00 to the plans.
I) Bubble cul-de-sacs are not allowed.
m) Show the water and sewer services to each lot.
n) Add a note to the plans that the well on the existing property must be abandoned and
proper documentation provided to the city.
o) Show all pipe crossings in profile.
p) Show the existing water service to the fountain and median irrigation in Wilds Parkway.
q) Add a catch basin at Street B.
r) Street A must end in a temporary cul-de-sac.
s) Show street and storm profiles on the same sheet.
3) The need for tree replacement needs to be documented.
4) Lot line easements need to be shown.
5) A copy of the covenants to be recorded on the property need to be submitted.
6) The width and area of the corner lots need to be adjusted to meet ordinance requirements.
Passed and adopted this 7th day of August, 2000.
YES NO
I Mader X Mader
Gundlach X Gundlach
Ericson X Ericson
Petersen X Petersen
Vacant Vacant
Frank
{Seal}
rSresoluti\planres\2000\OO-68.doc Page 2