HomeMy WebLinkAbout00-89 PRELIMINARY PLAT
RESOLUTION 00-89
RESOLUTION OF THE PRIOR LAKE CITY COUNCIL APPROVING THE PRELIMINARY PLAT OF
"CREEKSlDE ESTATES" SUBJECT TO THE CONDITIONS OUTLINED HEREIN.
MOTION BY: MADER SECOND BY: PETERSEN
WHEREAS: the Prior Lake Planning Commission conducted a public hearing on July 10, 2000 and
on August 14, 2000 to consider an application from Eagle Creek Villas, LLC and
Freedom Development for the preliminary plat of Creekside Estates; and
WHEREAS: notice of the public hearing on said preliminary plat has been duly published and posted
in accordance with the applicable Minnesota Statutes and Prior Lake Ordinances; and
WHEREAS: all persons interested in this issue were afforded the opportunity to present their views
and objections related to the preliminary plat of Creekside Estates for the record at the
Planning Commission hearing; and
WHEREAS: the Planning Commission and City Council have reviewed the preliminary plat according
to the applicable provisions of the Prior Lake Zoning and Subdivision Ordinances and
found said preliminary plat to be consistent with the provisions of said ordinances; and
WHEREAS the Prior Lake City Council considered an application for preliminary plat approval of
Creekside Estates on September 18, 2000; and
WHEREAS: the City Council finds the preliminary plat of Creekside Estates to be consistent with the
2020 Comprehensive Plan.
NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY OF
PRIOR LAKE, MINNESOTA:
A. The above recitals are incorporated herein as if fully set forth.
B. The preliminary plat of Creekside Estates is approved subject to the following conditions:
1) Outlot A must be dedicated as parkland on the plat.
2) "rh~ ,-,~ ...... ~- h ..... i,=,~ ~-,., p .... i,~o *h ...... ~,-~ .... ~ (d d)
.... ,- ............. ., ..... open ..... elete
3) The lighting plans for the parking lots must include a design of the light fixture and a
luminaire calculation to ensure the ordinance requirements are met.
rAresoluti\planres\2000\OO-89.doc Page 1
16200 Eagle Creek Ave. S.E., Prior Lake, Minnesota 55372-1714 / Pk. (612) 447-4230 / Fax (612) 447-4245
AN EQUAL OPPORTUNITY EMPLOYER
4) The landscaping plan must be prepared and signed by a registered landscape architect
and must be revised to meet all ordinance requirements, including numbers, size and
species of the plantings. This plan must also identify whether or not an irrigation system
will be provided, and an irrigation plan must be provided.
5) The developer must provide covenants for the congregate housing building. These
covenants must be in a form acceptable to the City Attorney and must be recorded with
the final plat.
6) The following issues identified by the Engineering staff must be addressed prior to final
plan approval:
a) In accordance with the City's subdivision ordinance 1006.208: "Roadways and
street intersections shall have right-of-way radii of not less than twenty-five feet
(25')."
b) The plat shows easement in easements and easements in proposed right-of-way.
Easements are not needed in the right-of-way. There are several areas where the
line types change and it is impossible to differentiate what the lines mean
(easement, wetland edge, etc.).
c) Submit detailed plans and specifications that show type and height of retaining
wall. All walls over 4 feet in height are to be designed by a registered engineer.
d) The bridge along the trail will be by Continental (30' span).
7) The following issues identified by the Building Inspections Department must be addressed
prior to final approval.
a) If provided, indicate means of lawn irrigation. May use separate service and
metering for billing purposes.
b) Provide a description of rental agreement and type of facility and services offered
in the apartments.
c) Relocate the three of the five fire hydrants. Place 3 westerly hydrants in green
areas across from building entrances. L1; W130', S30'; L2; NE 20', L3 E50'. Front
of hydrant shall be placed 5'-0" from curb and side of hydrants shall be placed 10'-
0" from curb adjacent to parking stall.
d) Provide fire lanes for fire apparatus response. Signage to read:" No Parking Fire
Lane by order of Fire Department". Indicate on a Site plan. Locate by Fire Hydrants
and. in front of building entrances in parking lot. UFC 1001.7.1.
e) Provide 96" clearance height in underground parking for Fire Departments fast
response apparatus. Provide explanation as to reason all three buildings have
different lower level floor to first floor elevations.
f) Provide a Post Indicator Valve (PIV) on sprinkler supply line into buildings. Locate
a minimum distance away the height of the building.
g) Provide two parking spaces at each building for commuter van. MSBC 1300.4100.
h) All Units not HDCP accessible must be HDCP adaptable and on a HDCP
accessible route. MSBC 1341 Table 16.2
rSresoluti\planres\2000\OO-89.doc Page 2
i) Provide accessible route from exterior HDCP parking to the building on west 24
units. Locate by front entrance to building. MSBC 1340.1103 Provide detail sheet
of HDCP ramp.
j) 54 Unit: confirm if all units are HDCP Accessible. Two 24 Units: Two percent of
Units must be HDCP Accessible. MSBC 1341 Table 16.2
8) An all-way stop sign shall be placed at the intersection of Five Hawks Avenue, Priorwood
Street and Tranquility Court.
9) Application for approval of a PUD Final Plan must be submitted within 90 days of the date
of approval of the preliminary PUD plan by the City Council.
Passed and adopted this 18th day of September, 2000.
YES NO
Mader X Mader
Gundlach X Gundlach
Ericson X Ericson
Petersen X Petersen
Vacant Vacant ,,~
{Seal}
e
r:~'¢solufi\p]amrcs\2000\00-89.doc Page 3