HomeMy WebLinkAboutFire Sprinkler Report - 7/29/10 ,; � �\ 24 Hour Service • D • �(� r • Commercial ��� �� T Business: (605) 582-2400 VV • Industrial 1004 Seventh Avenue North • P.O. Box 680 Fax (605) 582-7360 � _ • Residential Brandon, SD 57005 ���y , �, , / 1 �1 �,� � NAME OF PROPERTY �� iC �" ��-� S�5 � r� � � INSPECTION CONTRACT# ADDRESS � :- � � � �l Y r: �;s => '� �I j:'i i v INSPECTORS NAME '� -�-r � ''%��P c S d�n DATE OF INSPECTION ��"� /� �� �C�� INSPECTION FREQUENCY _MONTHLY _QUARTERLY �ANNUALLY _OTHER ALARM/MONITORING COMPANY PANEL# Yes N.A. No' 1. ��► a. Is the building occupied? b. Are all systems in service? c. Is occupancy completely sprinkled? d. Are all new additions and building changes properly protected? e. Is all stock or storage properly below spinkler piping? f. Was property free of fires since last inspection? (Explain any fire on Page 2) g. In areas protected by wet system, ddes the building appear to be properly heated in all areas, including blind attics, perimeter areas and are all exterior openings protected against entrance of cold air? 2. Control Valves (See Section 11) a. Wet sprinkler control valves open? b. Standpipe control"valve open? c. Dry system control valve open? d. Anti-freeze control valve open? e. Special system control valve open? f. Are afl control valves in good condition and locked open or supervised? g. Are all control valves accessible? 3. Water SuRplies (See Section 12) a. Was a water flow test made? 4. Tanks Pumos. Fire De� Connections a. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? b. Are fire department connections in satisfactory condition, couplings free, caps in place and check valves tight? 5. Wet $y�tems a. Have anti-freeze systems been tested and left in satisfactory condition? b. Are afarm valves, waterflow indicators and tamper switches in satisfactory condition? 6. Drv Svstems a. Is system in service on inspection? b. Does dry pipe valve appear free of damage? c. Are the trim valvs in the appropriate position? d. Is the alarm test valve closed? e. Is the air compressor operational? f. Is the oil level on the air compressor normal? �r g. Is any condensation drained off the air compressor? h. Are the highUlow pressure switches operational? i. Is the air maintenance device operational? j. Were the low points properly drained? k. Are the quick opening devices in service? I. Is the dry piope valve trip test satisfactory? m. Is the dry pipe valve and supply protected from freezing? 7. Snecial $jrstems (See Section 10) a. Were valves tested as required? b. Kitchen Hood? Heads cleaned or replaced? 8. Alarms a. Water motor and gong test satisfactory? b. Electric alarm test satisfactory? c. Supervisory alarm�service test satisfactory? 9. Sorinklers--Pinina a. Are all sprinklers in good condition, not obstructed, and appear free of corrosion or loading? b. Are all sprinklers less thank 50 years old? `` �. c. Is the piping, drain valves, check valves, hangers, pressure gauges, open sprinklers, strainers satisfactory? � d. Are all sprinklers of proper temperature rating? 10. Special systems: o? Type Make and Model? Condition? 11. Control Valves No? Type? Open Secured Closed Signs Condition C l Yes No Yes No Yes No Yes No Pump Control Valves -� Sectional Control Valves / y � system Control va�ves �S �'S I1 � ? 5 0 ? WATER FLOW TEST iz:"'°, ; Water Flow Test? �� 5 Qf none made, Why?) ' Size Pressure Flow Pressure Size Pressure Flow Pressure Test Pipe Lxated Test Pipe Test Pipe Pressure After Test Pipe Located Test Pipe 7est Pipe Pressure After r� ��:�,j t,�,. � ; _ _ _ . _ , . . , . . ,. .: . _, _ , .._.. _ _:.. .___ _ _ 13. NFPA 25 Manual present? G l' �� 14. Explanation of any "No" answers. y � � � 15lM�e��anps in buildina occuqancv or fire protection equioment /1 0�, 16. Adiustments or corrections made. /1 J n 17. Desirable Improvements. /� Oa „