HomeMy WebLinkAboutMaterial & Test Certifcate for Aboveground Piping - Contractor's Material & Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor s representative and aritnessed by an owner's representative. All defects sha{I be cosrected and system left in service before contractor's personnel finally leave the job. A cert�cate shall be filled out and signed by both represeMatives. Copies shall be prepared for approving authorities, owners, and corrtractor. It is understood the owner's representative's signature in no way prejudices any claim against contr�tor for fauky material, poor workmanship, or failure to comply with approving auttrority's requirements w local ordinances. PROPERTY NAME: JEFFERS POND DATE -- I 9.-1 Z PROPERTY ADDRESS: 14358 PARKSIDE GOURT ACCEPTED BY APPROVING AUTHORITIES: CITY OF WOODBURY ADDRESS: PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS �YES ❑NO EQUIPMENT USED IS APPROVED �YES ❑NO IF NO, EXPLAIN DEVIATIONS HAS PERSON IN CHARGE OF FIRE E�UIPMENT BEEN INSTRUCTED AS �YES ❑NO TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPIAIN 1NSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: �YES ❑NO �. SYSTEM COMPONENTSINSTRUCTIONS �YES ❑NO 2. CARE AND MAINTENANCE INSTRUCTIONS �YES ❑NO 3. NFPA25 �YES ❑NO LOCATION ENTIRE BULDING YEAR OF TEMPERATURE MAKE MqDEL MANUFACTURE SIZE QTY. RATING RELIABLE RES 49 2011 1/2 10 155 � SPRINKLERS RELIABLE RES 44HSW 2011 12 13 155 RELIABLE F3QR 2011 1I2 1 155 PIPE AND Type of Pipe BLAZEMASTER FITTINGS Type of Fitting CPVC M/WMUM TtME TO OPERATE ALARM DEVICE THROUGH TEST CONNECTION ALARM VALVE OR FLOW INDICATOR TYPE MAKE MODEL MIN SEC FLOW INDICATOR POTTER VSR-F DRY VAWE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE TIME TO TRIP TIME WATER ALARM OPERATING TEST THROUGH TEST WATER AIR TRIP POINT REACHED OPERATED CONNNEC710N' PRESSURE PRESSURE AIR PRESSURE TEST OUTLET' PROPERLY MIN SEC PSI PSI PSI MIN SEC YES NO W!O Q.O.D. W ITH Q.O.D. IF N0, EXPLAIN LOCATION MAKE & SETTING STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE & FLOOR MODEL FLOWING PRESSURE REDUCING INLET (PSI) OUTLET (PSI) INLET (PSI) OUTLET (PSI) FLOW (GPM) VALVE TEST N/A OPERATION: ❑PNEUMATIC ❑ELECTRIC ❑HYDRAULIC PIPING SUPERVISED ❑YES ❑NO OETACHING MEDIA SUPERVISED ❑YES ❑NO DOES VALVE OPERATE FROM THE MANUAI TRIP AND/OR REMOTE DYES ❑NO CONTROL STATIONS DELUGE & IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT IF NO, EXPLAIN PREACTION FOR TESTING VALVES OYES ❑NO N/A DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT MAXIMUM TIME TO YES NO YES NO MIN SEC HYDROSTATIC: Hydrosimic test sha11 be mede at nd less men 200 psi (13.6 be�s) ta lwo hours d 50 psi (3A bers) ahove s1aNc pressure �� � a�so ���o.z ��> ro. n� na,�. o��i a�� �an� ae� snan na �� a�,�� � w P��� aam�e. ai Aboveground piping lealmge shell ba sropped. TEST DESCRIPTION PNEUMATIC: Establish 40 psi (2.7 bers) air pressure and rt�easure drop, which shell nd e�xeed 1-1/2 pei (0.1 bars) in 24 houts. Test pressure tenks at nortnal weter level ami air pressure and rt�ure air pressure drop, which she11 not e�meed 7-12 pai (0.7 bers) in 24 houra. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HRS IF NO, STATE REASON DRY PIPING PNEUMATICALLY TESTED �YES �NO EQUIPMENT OPERATES PROPERLY �YES ❑NO N/A DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATNES OF SODIUM SILICATE, BRINE, OR OTHER CORROSNE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? YES NO DRAIN READING OF GAGE LOCATED NEAR WATER RESIDUAL PRESSURE WITH VE IN TEST CONNECTION TESTS TE3T SUPPLY TEST CONNECTION � PSI CONNECTION OPEN WIDE �SI UNDERGROUND MAINS AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING. VERIFIED BY COPY OF THE U FORM NO. 8.56 �YES ❑NO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING �YES ❑NO IF POWDER DRIVEN FASTENERS ARE USED IN �YES ❑NO IF N0, EXPLAIN CONCRETE, HAS REPRESENTATNE SAMPLE TESTING BEEN SATISFACTORILY COMPLETED9 BLANK TESTING NUMBER USED LOCATIONS NUMBER REMOVED GASKETS 0 WELDED PIPING �YES �NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR3? �YES ❑NO WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR3 �YES ❑NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISC ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? �YES ❑NO CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? �YES ❑NO HYDRAULIC NAMEPLATE PROVIDED IF NO, EXPLAIN DATA �YES ❑NO N MEPLATE REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VAWES OPEN: �—( 9.� �?� NAME OF SPRINKLER CONTRACTOR: FIRE SUPPRESSION SERVICES LLC TEST WITNESSED BY F�E OWNE (SIG D) TITL� DA� SIGNATURES ! , r �� � �_ OR SPRINK R C NTRACTO (SIGNED) �� ITLE ATE ✓ ,.�,. -/ 9 � / Z ADDITIONAL EXPLANATION AND NOTES