Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AT&T Open Permit 11.688 - Permit
�'pR \� CITY OF PRIOR LAKE BUILDING PERMIT, Date Rec'd ,7 / ''; \ \ TEMPORARY CERTIFICATE OF ZONING COMPLIANCE e AND UTILITY CONNECTION PERMIT ( i IA t. white File 2. Pink City PERMIT NO. iI G SS 3. Yellow Applicant (Please type or print and sign at bottom) ADDRESS (P E7 ZONING (office use) 5 s#0 CG_b4RWGob ST NE rtai Al- , ;/; L.1" s LEGAL DESCRIPTION (office use only) LOT t BLOCK 1 ADDITION a .31 Wig-CECIL rOw6.A. 4. PID (Naam OWNER f� l 4 T (Phone) 6 '�S --°1) n (Address) (-., C 6H 1 MEaa-( !A ar , G') N, 1 it44 PIs,. C -acmt, Mn) 5511 i BUILDER (Company Name) 4-T CV (Phone) 6[2.- ZS-0k - Ogg') (Contact Name) 5 S J T�v FJ1nA) (Phone) 60( ' s - 0 0) 8') (Address) UN a, A 6a9 i Vwc, (A) AJ MW C�ve f ) ssT( I TYPE OF WORK t7.rNew Construction DDeck ❑Porch DRe-Roofing DRe-Siding ['Lower Level Finish ❑ Fireplace DAddition [Alteration ['Utility Connection CODE: QLR.C. tI.B.C. ❑ Misc: Type of Construction: I II III 1V V AB Occupancy Group: A B E F H I M R S U PROJECT COST /VALUE $ I O, O0O s 00 Division: 1 2 3 4 5 (excluding land) I hereby certify that I have furnished information on this application which is to the best of my knowledge true and correct. I also certify that I am the owner or authorized agent for the above - mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building official can revoke this pe 't for just cause. Furthermore, I hereby agree that the city official or a designee may enter upon the property to perform needed inspections. X 5e9AK , — rte 6 —t— It Signature Contractor's License No. Date Permit Valuation o 000- r Park Support Fee # $ Permit Fee $ (a (5o SAC # $ Plan Check Fee $ ( Zg .48 Water Meter Size 5/8 "; 1 "; $ State Surcharge $ 5. _ 11 Pressure Reducer $ Penalty $ Sewer /Water Connection Fee # $ Plumbing Permit Fee $ Water Toweer Fee # $ Mechanical Permit Fee $ � r D si i G $ 50o. - Sewer & Water Permit Fee $ .Other '` OA Eview l'IN (d. $ 45 - Gas Fireplace Permit Fee $ TOTAL DUE $ S3 zo. 18 This • f li cation : ; ,, � : Y ur Building Permit When Appro • • Pa Re No. / , - 77 2 0 q b (, 3¢SS Date 7, Z , / B /.4444 1 z - 1r • 'il. ing Official ' Date This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and may proceed as requested. This document when signed by the City Planner constitutes a temporary Certificate of Zoning compliance and allows construction to commence. Before occupancy, a Certificate of Occupancy must be issued. i v" 7 — �s -- 1/ '�.sa° 4 Kr" reS4r,aye PI Director Date Special Conditions, if any 24 hour notice for all inspections (952) 447 -9850, fax (952) 447 -4245 4646 Dakota Street S.E., Prior Lake, Minnesota 55372 t. ' „ ■t■ *vie; EI , titt mmomminwien.. Hagen Engineering International, Inc Antenna Installation Structural Report May 25, 2011 Prepared For : Edge Consulting Engineers, Inc. 624 Water Street Prairie du Sac, WI 53578 Site Location : Prior Lake, MN Site ID MNL03028 HEI Number 11-2880 Prepared By : Ty Hagen, P.E. Hagen Engineering International, Inc. 750 South Plaza Drive, Suite 322 Mendota Heights, MN 55120 Telephone: (651) 686-5686 Fax: (651) 686-5685 ty©hagenengineering.com Ri: Revised Antennae Oil tibia,. R2: Corrected Heights & Anchor Bolt Diameter .** 7* * RIGNITERE0 •••„ *: PROFESSIONAL *t ENGINEER * *. 17062 : 11 "erstil JUL 21 011 Date Printed: 7121/2011 Page 1 of 7 Rev.2 t.4_400„ El Hagen Engineering International, Inc Site Location : Prior Lake, MN Site ID : MNL03028 Executive Summary: The tank is a 1,000,000 gallon HydroPillar built by PDM in 1988. We have been provided with Construction Drawings, site photographs, site notes and antennae information. This information along with historical data was used in our analysis. AT &T is proposing to remove six (6) of their existing antennas and replace them with nine (9) new panel antennae. These new antennae along with existing antennae were included in our analysis. A complete list and description of the antennae are shown on sheet 4 of this report Our analysis confirms the following: • The adequacy of the existing structure to support the proposed loadings • Adequacy of the proposed railing attachments • Adequacy of the existing railing to support the proposed loadings • Adequacy of the structural details shown on the Construction Drawings. Conservative loading has been assumed such that minor variances from the above will not affect the stress results. An analysis was done for the basic tank structure. The analysis was performed using a design wind speed of 100 mph. Calculations demonstrate that the structure is capable of resisting the additional loads from the antennas. The foundation anchorage was evaluated for the above wind loadings and was found to be adequate for the additional loading. Based on our experience, the foundation should be adequate for the relatively small increase in loading. Date Printed : 7/21 /2011 Page 2 of 7 Rev.2 / 1" ki Hagen Engineering International, Inc Site Location : Prior Lake, MN Site ID : MNL03028 Information From Capacity 1,000,000 Gallons Drawings Tank Manufacturer PDM Drawings Year Built 1988 Drawings Type HydroPillar Drawings Tank Diameter 74 Ft. Drawings Height to BCL 96.5 Ft. Drawings Head Range 40 Ft. Drawings Height to HWL 136.5 Ft. Drawings Fluted Column Height 102 Drawings Fluted Column Diameter 52 Ft. Drawings Number of Anchor Bolts 24 Drawings Anchor Bolt Dia. 1.5 In. Drawings Tank Weight 524,120 Lbs Drawings Water Weight 8,341,688 Lbs Historical Live Load 107,521 Lbs Historical Design Wind Speed 100 mph Historical Tank Wind Load 40,000 Lbs Historical Based on 100 mph (fastest mile) Height Above Top Of Col 20 Ft. • Date Printed : 7/21/2011 Page 3 of 7 Rev.2 El Hagen Engineering International, Inc Site Location : Prior Lake, MN Site ID : MNL03028 Antennae Carrier # Antennas Antenna Model Elevation Location /Notes (feet) AT &T 6 Andrew DBXLH -6565B 153 See field notes, existing loading to be replaced 3 (3) Katherine 80010766 3 (3) Katherine 80010765 3 (3) Katherine 80010764 AT &T 153 Proposed AT &T Loading 6 (6) TT19- 08BP111 -001 (TMA' 6 (6) CM1007- DBPXBC -003 -2 (Dipiexer) 6 (1) 860 -10006 (RET Control) 1 (1) 10' x 2" dia omni antennae Sprint 6 90' -0" See field notes, to remain (3) Antel BCD 80609 T- Mobile 9 Channel Master 3041124 87' -0" See field notes, to remain Verizon 1 Ericsson 24" dia solid dish 73' -8" See field notes, to remain Unknown 2 (2) 8' x 3" omni antennas 138' -0" See field notes, to remain 1 (1) 12' x 3" omni antenna Antennae Loads Number Area Pressure Force Y -Bar sq.ft. psf Ibs ft 18 96 30 2,880 153 Includes Unknown 15 120 30 3,600 90 Combine Sprint and T Mobile 1 5_ 30 150 73.67 Date Printed : 7/21/2011 Page 4 of 7 Rev.2 *±' El Hagen Engineering International, Inc Site Location : Prior Lake, MN Site ID : MNL03028 Wind Calculations Without Antennas Item Area Pressure Force Y -Bar Moment Sq. Ft. PSF Ibs Ft. Ft. -Lbs Tank 40,000 122 4,880,000 Fluted Column 5,304 21 111,384 51 5,680,584 10,560,584 Total Wind Load =2M /R= 812,353 Ibs With Antennas Item Area Pressure Force Y -Bar Moment Sq. Ft. PSF Ibs Ft. Ft. -Lbs Tank 4,880,000 Fluted Column 5,680,584 Antennas & Supports 2,880 153 440,640 Antennas & Supports 3,600 90 324,000 Antennas & Supports 150 73.67 11,051 11, 336, 275 Total Wind Load =2M /R= 872,021 Ibs Antenna Increase = 6.8% Total Load at base without wind DL + Water + LL = 8,973,330 Ibs Anchorage Check Anchor Area = 1.29 Sq. In. Load Per Anchor Bolt = 14,496 lb/bolt Stress = 11,237 psi < 24,000 psi Date Printed : 7/21/2011 Page 5 of 7 Rev.2 Antenna Support Review and Analysis Existing Supports Area S inA2 inA3 Braces Angle 2x2x1/4 0.938 Post Pipe 2" Sch 40 1.07 0.731 Antenna Wind Loads (Based on 100 mph- fastest mile) Front 200 Ibs Antenna Length 8 ft Brace Height 3.75 ft Brace Toad = P /(2 * Cos 45) = 141.4427 Ibs fa = 151 psi OK by inpsection • Post M =P *L P = 200 Ibs L = 3.75 M = 750 ft-Ibs fb = M * 12 /S= 12,312 psi < 20,000 psi * 1.33 = 26,600 psi Existing supports are adequate for antenna loads Date Printed : 7/21/2011 Page 6 of 7 Rev.2 V4> . El Hagen Engineering International, Inc Site Location : Prior Lake, MN Site ID : MNL03028 General Welding Notes 1. All welding, including weld procedures and welder qualifications shall be in conformance with AWWA D100 -96. 2. All welds in the tank and structural attachments shall be made in a manner to ensure complete fusion with the base metal, within the limits specified for each joint, and in strict accordance with the qualified welding procedure specifications. Weather and temperature conditions. Welding shall not be performed when the surfaces of the parts to be welded are wet from rain, snow, or ice; when rain or snow is falling on such surfaces; or during periods of high winds, unless the welder or welding operator and the work are properly protected. Welding shall not be performed when the base metal temperature is lower than 32 °F (0 °C) unless the base metal within a distance of four times the plate thickness (3 in. [76 mm] minimum) of the place where welding is to be started is preheated to at least 100 °F (37.8 °C) and this temperature is maintained for the distance ahead of the arc set forth above as welding progresses. It is recommended that no welding be done when the base metal temperature falls below 0 °F (- 18 °C). If welding is to be performed when the base metal temperature is lower than 0 °F (- 18 °C), the following special requirements are to be met. a. Low - hydrogen electrodes or low- hydrogen welding shall be used. b. The base metal along the length of the weld joint in the direction of welding shall be preheated to 200 °F (93 °C) and maintained as welding progresses for a distance of at least 36 in. (914 mm) from the point of welding or the entire weld joint length, whichever is less. In addition, the area extending on both sides of the weld joint a distance of four times the plate thickness, but not less than 3 in. (76 mm) or more than 6 in. (152 mm), shall be preheated to and maintained at 200 °F (93 °C) during welding. Date Printed : 7/21/2011 Page 7 of 7 Rev.2 1 i4/te.lii�'&/iv L4$ -F/Sct ! u-obge ' '- . ,.,...: KEW ENGINEERING INC P.O.Box 897.3394 Lake Elmo Ave.N.•Lake Elmc,MN 55042 (651)773-5111•Fax(651)773-5222 August 12, 2014 By Email Only: Nick Zurbey Public Works Technician 17073 Adelmann St. SE Prior Lake, MN 55372 RE: Final Walk through Inspection/Punch List on Cedarwood Tower in the City of Prior Lake,MN. AT&T site FA No. 10081745, KLM Project MN 2840. Dear Mr. Zurbey, KLM Engineering Inc. performed a final walk through/punch list on the above mentioned tower in Prior Lake, MN and has the following comment: KLM Engineering Inc. found the install to be completed per the approved drawings and found no coating damage or areas that will require repair. Please consider this letter as verification that the scope of work detailed in the above mentioried drawings has been completed and approved. The above punch list has been prepared by Rodney Ellis of KLM Engineering Inc. and constitutes his understanding of issues unresolved for completion of the project. The owner reserves the right to add to or modify this list to meet their requirements. If you have any comments, questions or corrections concerning these issues,please contact the undersigned in writing immediately. Sincerely, KLM Engineering,Inc. .,-;--ro,,,4,,,,,:,,,Z---- Rodney Ellis Telecomm Supervisor CC: Michelle Nelson, KLM\Office File C:\Users\Owner\Desktop\Antennas\2014\Final Punch Letters\MN2840 Prior Lake Cedarwood Tower AT&T.Doc