Loading...
HomeMy WebLinkAbout93-65 RS9365 RESOLUTION 93-65 RESOLUTION OF THE PRIOR LAKE CITY COUNCIL TO APPROVE THE PRELIMINARY PLAT OF THE ECHOS. MOTION BY: WHEREAS, WHITE SECOND BY: SCOTT the City Council held a public hearing on the 2nd day of August, 1993 to consider a petition submitted by John C. Andren to approve the Preliminary Plat of The Echos; and WHEREAS Notice of the public hearing on said motion has been duly published and posted in accordance with the applicable Minnesota Statutes. NOW, THEREFORE, BE IT RESOLVED BY THE CI1Y COUNCIL OF PRIOR LAKE, MINNESOTA, that it should and hereby does approve the Preliminary Plat of The Echos subject to the following: 1. Sewer, water, street and stonn water plans should be revised and submitted acceptable to the City Engineer. 2. All lots must contain 90' of lot width at the front setback line and 75' of width at the 904 contour line. The preliminary plat should indicate the lot width measured at the 904 and 25' front yard setback line. 3. Utility and drainage easements be provided along lot lines, for any public improvements and for the drainage low area on Lots 2 and 3. 4. A site construction plan should be provided. 5. Utility service lines per City policy are to be installed to the utility and drainage easement lines. 6. The culvert shown to drain Lot 1 under Lot 2 driveway should be eliminated. Drain Lot 1 area to stonn sewer pipe. Convert to stonn sewer system. Manhole by Beach Street has an invert elevation of 902.40. 7. Developer should provide 100 year flood elevation for low area and survey elevation of emergency overflow of this area. 8. Developer should provide an additional easement on Lot 3 for emergency overflow spillway of the low area on Lot 3. 4629 Dakota St. S.E., Prior Lake, Minnesota 55372 / Ph. (612) 447-4230 / Fax (612) 447-4245 AN EQUAL OPPORTUNITY EMPlDYER 9. A planting concept plan addressing tree planting requirements of Section 6-7-1 of the Subdivision Ordinance should be submitted, acceptable to the City Planning Director. 10. Fill is pennitted as part of a development project in areas above 904 provided a grading pennit is obtained from the City of Prior Lake. Fill must be protected from erosion by vegetation or other methods. Filling pennits and Building pennits proposed within the Flood plain district must be filed in duplicate with the City which will forward one copy to the DNR for review and comment. 11. Low floor elevation is 909. Finished fill elevation on each proposed lot shall be at least at elevation 908, measured IS' beyond the limits of any structure. A grading, drainage and erosion control plan should be submitted acceptable to the City Engineer and DNR. 12. All proposed lots must contain a building pad at or above elevation 909. The grading plan should be revised anticipating future removal of the existing home on Lot 2, and showing a future grading plan consistent with provisions of the Flood Plain Ordinance. 13. All public utilities and facilities such as gas, electric, sewer, water located within the flood plain at an elevation lower than 909 shall be flood proofed in accordance with the State Building Code or elevated above 909. Passed and adopted this 2nd day of August, 1993. YES NO Fitzgerald Kedrowski Scott White x X X Fitzgerald Kedrowski Scott White. x *NOTE: Andren vacated the chair and did not participate in the Council discussion. Frank Boyles City Manage City of Prior Lake { Seal}