Loading...
HomeMy WebLinkAboutTank Removal Permit 10. 0865 5 0 T. 0 00000 0 ID 0 > k-O 'O 0 0 0 N?,Z T 7o 'r1m p 0 0 3 mDC z m m m 0 0 o m m 0 m Z >k 0 0 0 � t ?y t � > - D > 1 z m 0 Z O D O Z fC m ► O „0t > N O Z Z O0 i. • m ` n Z J � ^ ; m m • 1 1...., , 4' m° o o Z 7J 0000❑❑ `I x m m m . -.y1 3 � � '�3 � o -I z o o oc )' • - x3rrimx3 13 0 N o C m ` i Z 3 ? \ m oO s v ` mo o 0 i 6 ,; 0 (� n O O _{ C O try Z ' m r D -vv O , \ m o A 0 �� N ( l v = m o c 0 CAI y z z \ G, o m > R. z A73 �0� m R. < o 13 ' m o ro o ,` • Z A00Zi � ,� m x -n�-� �`� ± Z _ z m -I r D • 0 Report Title: Tank Site and Owner Information Report Number: 43 Minnesota Pollution Control Agency TALES Report 12 September, 2013 Prior Lake Marathon Service Station Site ID: 4370 Type of Site: Underground Only Address: 4995 160th St SE Region: M Prior Lake, MN 55372 AST Registration: County: Scott UST Registration: 3/31/1986 Site Phone: NO CORE PI PH. Contact Phone: Old Phone: 9524476325 ************, r, r, r, r**, r ,rvrvr,r *,v *,r *,r * * ** *vr,rvr,v* OWNER INFORMATION * * * * * * * * * * **** * * *,r * *,r *,v, ****** *** *** Owner Name: Prime site Investments Owner ID: - 276471 Address: 15287 Edinborough Ave Prior Lake, MN 55372 **** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TANK INFORMATION SUMMARY ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *, Nbr A/U Status Substance Stored Capacity Installed Removed Reg Date 001 U Removed Gasoline 10,000 11/25/1980 09/29/2010 03/31/1986 Removal Contractor: MINNESOTA PETROLEUM SERVICE INC 002 U Removed Gasoline 10,000 11/25/1980 09/29/2010 03/31/1986 Removal Contractor: MINNESOTA PETROLEUM SERVICE INC ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 001 - COMMON TANK INFORMATION * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Our Tank Nbr: 001 U Client Tank Nbr: 001 Dispenser Type: Submersible Total Capacity: 10,000 Tank Const Mtl: Bare /Paint /Asph Coat Steel Stored Product: Gasoline Used For Heating ?: U Tank Status: Removed Tank Disposal Company: MN PETROLEUM 2nd Cont Tank: Tank Cath Prot: Impressed Current Pipe Cath Prot: Impressed Current Pipe Material: Galvanized steel Piping Material Desc: HW Generator ID: MND045956943 Product Replaced Date: Tank Registration Date: 03/31/1986 Unreg Tank Report Date: 001 - UST TANK INFORMATION # of Tank Compartments: 1 Compart Number: 1 Compart Capacity: 10000 Compart Stored Prod: Gasoline Compart Stored Desc: GASOLINE Compart Other Desc: - - -- Overfill Information - - -- Overfill Prot Alarm: Overfill Prot Autoshut: Y Overfill Prot Ballfloat: Overfill Prot Manual: Overfill Prot No Info: Overfill Prot None: Overfill Prot Type Unk: - - -- Tank Release Protection - - -- - - -- Piping Release Protection - - -- Daily Stick: N Auto Line Leak Detection: Y Tightness Test: N Annual Tightness Test: Y Manual Gauging: N Vapor Monitoring: N Auto Gauging: Y Groundwater Monitor: N Soil Vapor Monitor: N Interstit Monitor: N Groundwater Monitor: N 3 Year Tightness Test: N Interstit Monitor: N European Suction: N SIR Approve Date: SIR Approve Date: SIR Vendor Nbr: 0 SIR Vendor Nbr: 0 Other Desc: Other Flag: Y ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 002 - COMMON TANK INFORMATION * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Page 1 of 6 Report Title: Tank Site and Owner Information Report Number: 43 Prior Lake Marathon Service Station Site ID: 4370 Type of Site: Underground Only Our Tank Nbr: 002 U Client Tank Nbr: 002 Dispenser Type: Submersible Total Capacity: 10,000 Tank Const Mtl: Bare /Paint /Asph Coat Steel Stored Product: Gasoline Used For Heating ?: U Tank Status: Removed Tank Disposal Company: MN PETROLEUM 2nd Cont Tank: Tank Cath Prot: Impressed Current Pipe Cath Prot: Impressed Current Pipe Material: Galvanized steel Piping Material Desc: HW Generator ID: MND045956943 Product Replaced Date: Tank Registration Date: 03/31/1986 Unreg Tank Report Date: 002 - UST TANK INFORMATION # of Tank Compartments: 1 Compart Number: 1 Compart Capacity: 10000 Compart Stored Prod: Gasoline Compart Stored Desc: GASOLINE Compart Other Desc: - - -- Overfill Information - - -- Overfill Prot Alarm: Overfill Prot Autoshut: Y Overfill Prot Ballfloat: Overfill Prot Manual: Overfill Prot No Info: Overfill Prot None: Overfill Prot Type Unk: - - -- Tank Release Protection - - -- - - -- Piping Release Protection - - -- Daily Stick: N Auto Line Leak Detection: Y Tightness Test: N Annual Tightness Test: Y Manual Gauging: N Vapor Monitoring: N Auto Gauging: Y Groundwater Monitor: N Soil Vapor Monitor: N Interstit Monitor: N Groundwater Monitor: N 3 Year Tightness Test: N Interstit Monitor: N European Suction: N SIR Approve Date: SIR Approve Date: SIR Vendor Nbr: 0 SIR Vendor Nbr: 0 Other Desc: Other Flag: Y * *** * ** * *** * ** * * ** *** * ** *ter * * ** * * * *** CORRESPONDENCE ****** * *** * * * * * * * ** * ** * * * * **** * ** ** ** Number: 1 Date: 01/01/1901 Company: Person At Co: Type: Registration Form PCS: Number: 2 Date: 09/11/1998 Company: CORRPRO COMPA Person At Co: CRAIG Type: Registration Form PCS: PRE - NOTICE OF THE INSTALL OF IMPRESSED CURRENT ON UST'S 001 & 002 Number: 3 Date: 11/17/1998 Company: TOM THUMB (NO Person At Co: BLO Type: Registration Form PCS: BRYAN ENTERED IP AND SPILL AND OVERFILL FOR TANKS 1 & 2 PER NOT./CHANGE FORM. Number: 4 Date: 08/20/1997 Page 2 of 6 Report Title: Tank Site and Owner Information Report Number: 43 0 Prior Lake Marathon Service Station Site ID: 4370 Type of Site: Underground Only Company: TOM THUMB Person At Co: LELAND NOKES Type: Audit PCS: RS 8/20/97 AUDIT WAS RECEIVED. Number: 5 Date: 09/09/2003 Company: Person At Co: Type: Registration Form PCS: JCH NEW OWNERSHIP OF SITE- TOM JONES OWNER 9/9/2003 - Number: 6 Date: 03/30/2004 Company: PRIOR LAKE MARATHON Person At Co: Type: Phone Call PCS: NAB 3/30/04 CALLED STORE REGARDING STATUS OF TESTING THAT WAS NEEDED TO BE DONE. I PUT OFF UNTILL SPRING BECAUSE CP TESTING WAS REQUIRED. LEFT MESSAGE WITH STORE CLERK FOR JOHN MAHMAD TO CALL ME BACK BY FRI IN ORDER FOR THE CW NOT TO TURN INTO A FIELD CITIATION. Number: 7 Date: 09/15/2004 Company: PRIOR LAKE MARATHON Person At Co: Type: Field Notes PCS: NAB MLLD TEST PASSED FOR 2 TANKS ON 9/16/05 TESTED BY GRIFFIN LINE TIGHTNESS TEST PASSED FOR 2 LINES ON 10/12/03 Number: 8 Date: 01/30/2006 Company: GRIFFIN PETROLEUM Person At Co: Type: Registration Form PCS: JCH 1/30/2006 RECEIVED NOTIFICATION FORM FROM GRIFFIN PETROLEUM FOR INSTALLATION OF STAGE 1 VAPOR RECOVERY FORM SIGNED JOHN MAHMOUD, OWNER 1/26/2006 Number: 9 Date: 12/10/2007 Company: Prior Lake Marathon Person At Co: John Mahmoud Type: Field Notes PCS: JPB Site visit 12 -7 -07. No records of any testing. No form of tank leak detection, line tightness, MLLD, CP test, rectifier reading. 2 spill buckets contain debris. Old owner under new name, John Mahmoud previously Prime North Investments now Maya Properties. JPB Number: 10 Date: 03/20/2008 Company: Prior Lake Hot Spot Person At Co: John Mahmoud Type: Letter PCS: JPB Issued Field Citation on 3- 20 -08. Mr Mahmoud has not returned calls or has promised that he would send info. and then not. Only work conducted to date is line tightness and MLLD check. JPB Number: 11 Date: 04/17/2008 Company: Prior Lake Hot Spot Person At Co: John Mahmoud Page 3 of 6 Report Title: Tank Site and Owner Information Report Number: 43 0 Prior Lake Marathon Service Station Site ID: 4370 Type of Site: Underground Only Type: Meeting PCS: JPB Field Citation appeal meeting with John Mahmoud. Agreed to reduce fine by $1,000 if John could produce signed contract to conduct CP and signed SIR contract. Also agreed to not issue field citation to Chaska Hot Spot if John would do the same here. John must provide MPCA with the contracts by 4- 29 -08. JPB Number: 12 Date: 08/26/2008 Company: Prior Lake Hot Spot Person At Co: John Mahmoud Type: Phone Call PCS: JPB Per phone conversation with John Mahmoud he has a proposal from Pump & Meter to repair the Impressed Current system. No date has been set to begin work. JPB Number: 13 Date: 09/24/2008 Company: Prior Lake Hot Spot Person At Co: Raymond Type: Meeting PCS: JPB Per conversation with Raymond from Pump & Meter, they are negotiating with Hot Spot to conduct CP repairs, Hot Spot is claiming to not have the Money. JPB Number: 14 Date: 10/29/2008 Company: Prior Lake Hot Spot Person At Co: Jeff Barry Type: Phone Call PCS: JPB Per phone conversation with Jeff Barry of GPS and John Mahmoud of Hot Spot, Gen. Corr is to repair CP. They are waiting for Marty to send paperwork so that a contract can be signed and a down payment made. JPB Number: 15 Date: 02/04/2009 Company: General corrosion Person At Co: Type: CP PCS: JAB 6/20/2008- CP on tanks and piping failed. JAB Number: 16 Date: 04/02/2009 Company: ELK RIVER BP Person At Co: RAJESH TANDON Type: Letter PCS: RRH 4 -02 -2009 SETTLEMENT AGREEMENT AND CONFESSION OF JUDGEMENT SENT Number: 17 Date: 06/24/2009 Company: Prior Lake Hot Spot Person At Co: John Mahmoud Type: Field Notes PCS: JPB Instal red tags on 2 tanks, hand deliver red tag letter to John Mahmoud. Reg tank 3000 gal, prem tank 800 gal. JPB Number: 18 Date: 07/29/2009 Company: Prior Lake Hot Spot Person At Co: John Mahmoud Type: Phone Call PCS: JPB Per conversation with John Mahmoud, General Corrosion has completed repairs to the impressed Page 4 of 6 Report ride: Tank Site and Owner Information Report Number: 43 0 Prior Lake Marathon Service Station Site ID: 4370 Type of Site: Underground Only current system and will return at end of month to retest the CP. JPB Number: 19 Date: 08/12/2009 Company: Prior Lake Hot Spot Person At Co: Marty lozza Type: Phone Call PCS: JPB per conversation with marty iozza the CP has been retested and all passed. marty will complete report and submit soon. JPB Number: 20 Date: 02/05/2010 Company: Prior Lake Hot Spot Person At Co: Kerry Tullis Type: Phone Call PCS: JPB Kerry Tullis noticed the Belle Plaine Hot Spot was closed. I called the Prior Lake Hot Spot and the phone was disconected. Also called John Mahmoud and his cell number is disconected. Called property owner Dean (952- 447 -4153) and left a message. JPB Number: 21 Date: 02/19/2010 Company: Dean Morloc Person At Co: Type: Phone Call PCS: JPB Per conversation with property owner Dean Morloc, John Mahmoud closed the station and skipped town on 11 -1 -09. Dean intends to have the tanks removed in the summer of 2010. JPB Number: 22 Date: 03/02/2010 Company: Prior Lake Hot Spot Person At Co: Type: Field Notes PCS: JPB Facility closed, orange tagged fill pipes. The premium tank has 2 1/4" of product and the regular tank has 2 1/2" of product. The premium fill cap is broken. JPB Number: 23 Date: 06/06/2011 Company: PRIOR LAKE MARATHON Person At Co: Type: Registration Form PCS: JCH RECEIVED NOTIFICATION FORM TO CHANGE OWNER NAME AND LISTING 2 TANKS REMOVED 001,002 9/29/2010 FORM SIGNED KIRBY MORLOCK, PSI PARTNER 6/6/2011 ****** * ** * ** ** ** ** * * * * * *** * ** ** * *** ** INSPECTIONS ****** * * * * * * * * * * * * ** *** * * * * * * * * * * ** ** Date: 12-AUG-97 Type: Routine Reason: Audit Visit Date: 09- SEP -03 Type: Routine Reason: Facility Violation: UPRD071 Inadequate leak detection provided for piping. Violation: UREP096 Tank cathodic Protection Test Not Conducted At Least Every 3 Years Page 5 of 6 Report Title: Tank Site and Owner Information Report Number: 43 Prior Lake Marathon Service Station Site ID: 4370 Type of Site: Underground Only Violation: UREP113 Piping cathodic protection test not conducted at least every 3 years. Violation: UTRD070 Inadequate leak detection provided for tank. Date: 08- SEP -04 Type: Targeted Reason: Site Visit Date: 07- DEC -07 Type: Routine Reason: Facility Violation: UPRD073 Failure to conduct annual line leak detector function test. Violation: UPRD119 Failure to conduct annual line tightness test. Violation: UPRD134 Piping leak detection records not retained for at least 10 years. Violation: UREP096 Tank cathodic Protection Test Not Conducted At Least Every 3 Years Violation: UREP099 Impressed current rectifier reading not conducted /recorded at least every 60 days. Violation: UREP113 Piping cathodic protection test not conducted at least every 3 years. Violation: UREP116 Spill containment is inadequate or not functional. Violation: UTRD158 No leak detection provided for tank. Date: 24- JUN -09 Type: Targeted Reason: Site Visit Date: 02- MAR -10 Type: Routine Reason: Facility Page 6 of 6