Loading...
HomeMy WebLinkAboutPermits 00-0469,561,941,578 ',. DATE RECEIVF.1i CITY OF PRIOR LAKE, J J BUILDING PERMIT, C./ 30 UD TEMPORARY CERTIFICATE OF V ZONING COMPLIANCE AND UTILITY CONNECTION PERMIT Permit No. DIRECTIONS SPACES NUMBERED 1 THRU 17 MUST BE FILLED IN BEFORE PERMIT IS ISSUED (Please Print or Type and sign at bottom) 2. SITE ADDRESS .. 1. DATE 5- 30 '- 00 BUlL 11. SIZE OF (Height) /~/~ U// d. ,qck/,4tlf1 . PID 6l0"-363- 0-03-0 12. NO. OF STORIES 3. LEGAL DESCRIPTION LOT 1 . BLOCK ADDITION 'FOe..tot Au U ~ l \~ (Name) /;Jl (N me) ~ 6. BUILDER (Name) WQ."~O 1:C~L' 1. White 2. Pink 3. Yellow File City Applicant fJd-- 1G:> 1- INFORMATION UCTURE (Width) (Depth) 13. TYPE OF CONSTRUCTION 14. FLOOR AREA APPORTIONMENT USE 15. NUMBER OF OCCUPANTS OR SEATS OCCUPANTS 4.011:rb 5. ARpHITECT ..J .5 L (Address) EAJ;\"-i (Tel. No.) le5S PM~ IJIII.I<. ~/-l/O&- t.fi ~djlress) I (Tel. No.) I I~J I J'11/1lJ-i. 1 L l.#'l- 9. ~ - {O~ 3 i0;S f1t\t~drf)t:ve 'E>y',b lOO (Tel. No.) f"A)flW I Mil · '65",2."2 lt6, - 4-Dt.c -4400 7. TYPE OF WOR~ ~ New Construction K Chimney 0 Misc. 8. PROPERTY AREA OR ACRES Septic 0 Addition 0 Re-roofing 0 Porch 0 Re-siding 0 Finish Basement 0 SEATS Fireplace 0 Alterations 0 Deck 0 Finish Attic 0 9. PROPERTY DIMENSIONS 1 O. CULVERT SIZE Sq.Ft. Width Depth Yes No I hereby certify that I have fumished information on this application which is to the best of my knowledge true and correct. I also certify that I am the owner or authorized agent for the above mentioned property an that II constru . n will conform to all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building 0 . i can r.evoke this it f just ca urthermore. I hereby agree that the ~ !?fficial or a designee may enter upon the property to perform needed in~pections. 'OU~ ~ olOI5-r.JlPf)-S- 5-30"00 License No. Date FOR ADMINISTRATIVE USE SETBACKS: Required Actual SOIL TESTS MATERIAL FILED WITH APPLICA nON o o ENERGY DATA Front Back Side Side PILING LOGS 0 PERCOLATION TESTS 0 0e.. er ~8f' ................................... $ 1" PR.e:~"u~e; {<EQ $ 'I II \12, Pressure Reducer .......................... $ Met5111.').., ..l~'..lJAn;tt:...~.~..... $ l L/;'water Meter. .... ......~..................... $ \ 7-OD. e.1 Sewer & Water Connection Fee ......... . $ Water Tower Fee ...)/?~::.....~..1.. $ Water Tap ................................... $ pr ~ ~ Builder's Deposit ............................ $ .. Other ......................~.}:I~:?0..~ $ sq I to \ 1 .1 \ t-e77eJ2-0P0 ~'1r Total Due .............................. $ d/"~ 0/7. 7 I Certificate of Occupancy I (J I /(J ~ I ~ ~ '0 ,-z,() () Paid --C-, ' Receipt No. Issued r~ ~ '. /;V 6-~ l:Y..... Date By This is to certify that the request in the above application and accompanyin~tc~~'1{1~<girdan e with the City Zoning rdinan e and may proceed as 'iign y City Planne stitu tem rary Certifi t of Z nin mpliance and allows construction to commence. Before occupancy, a Certificate of BUILDING DEPARTMENT VALUATION OFF STREET PARKING SPACES REO. SPACES ON PLAN PERMIT VALUATION /, hOO, 00(;; - PLOT PLAN 0 PLANS & SPECS 0 SURVEY 0 USE OF BUILDING j / G I Y'UAJ TYPE OF CONSTRUCTION: I I III IV V 11 Occupancy Group A B E F H I (f!) R ~ U Division 1 2 3 4 . Z. S; Permit Fee ................................... $ G, "" Z. ~t~~fe .............p.............. $ _ 4 3 ~O. ~ r; 00 - · ( 000" ~()O ~oo ~ ~ 1 40 00 ,\<E..I= ur--J D State Surcharge ..........:n,.........-:\. l'\....1 ;'Ii . \" A 0 0 &() Penalty ....................................... $ 1/ ~ J 0 0 ~.D 1-\ City: Amount Brought Forward .................. $ Park Support Fee ..~~...:Ik'1........ $ SAC ....... ..11 Q Q ...~.... ..~J........ $ 1 ;" L Collective Street Fee ....................... $ Plumbing Permit Fee ....................... $ Mechanical Permit Fee ............. ....... $ This A By SETS COPIES s 1 so - L ,00." 10. - \ 40." 'l 50 . .. 1/5.- 8400.- 4 q 00. - Special Conditions if any 24 hour notice for all inspections (952) 447-9850 GIllEN . FILE YELLOW - APPLICANT GOLD - CIT., CITY OF PRIOR LAKE SEWER AND WATER PERMIT S.W.No. 00-05& / NOTE: Sewer and Water contractors must be registered with the city. APPLICANT: R~ G,~"'RA.C.,llN C:::'\ ADDRESS: ~1Q - ~ Av i :S~~ SIGNATURE: SITE ADDRESS: PHONE:(qCS;Z.) fftLj-32CO l J~/ ro BLDG. PERMIT # (JO-o4-b7 O()!v77J/N 1f/~5PID# 2h-~3 - 003-0 FILL IN THE BLANKq~. c...<- DATE: 1. Estimated length of water service feet. t \\ - , '0 - J.: .. V' (... i l.nch (es). 4"- b:,~~+1 L ,If - J:~~' from structure feet. PVC~ Cast Iron 2 . Size of water service 3 . 4 . Location of any couplings Type of sewer pipe. ABS 5. Estimated length of sewer line feet. 6. Clean out (if required), located at structure. feet from ==~======~===~====================~==================pG~=~:~~~) Th1.S .~~on becomes your perm~t when approved. S-II-oo P'-A~S. BY / ;1 ~ DATE: 7-.>-tJl) ====:===============~~~J1~~=1f:~:1~~=~~==E:~2J~=';J:?t=== FEES: L{ or r 2...9:> $ $ $ water line ponnection permit. I~ .f ~\. G:&{. * individually is $j.?~ plus * Sewer and water permits issued for new construction must be recorded on the building permit card at the time of issuance to insure that no duplicate sewer and water permits are issued. DATE PAID 7/S/{}Q RECEIPT # 3765Z-- ::~:T B:~O 16200 Eagle Creek Av. S.E., Prior Lake, Minnesota 55372 / Ph. (612) 447-4230/ FAX (612) 447-4245 An Equal Opportunity Employer ~ TATE SURCHARGE TOTAL PERMIT FEES HEATING PERMIT FEE $ $ $ .50 ~ eoD lo~ .;.-- Receipt # Est. Comp. Date eP -- BUil~ Permit . f\- :3B(p2J tSD Est. Alterations Repair Cost $ Replacement New Construction ^ I hereby apply for a mechanical systems permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the ordinances and codes of the city and with the state building/mechanical codes; that this form does not become a permit until signed by the BUILDING OFFICIAL; that the work will be in accordance with the approved plan in the case of all ork which requires review and approval of plans. efm. TYPE OF WORK 447-4230 Return Openings eo~3.rlP,ooO- Input e1.ZfJ or. :>utout ~eo~ 'f ,;;r Edr. City Hall 4:30 p.m. ALL WORK MUST BE INSPECTED (ROUGH-IN AND FINAL) CALL CITY HALL Supply Openings liP. crt:O ."50 Conn. Load ~Pr\.~lue Size Fuel TYPE OF SYSTEM Warm Air Plants Gravity __ Mechanical _ Air Conditioning Vent. System HEATING OR POWER PLANT Steam Hot Water ~ Radiation _ Special Devices business hours are 8 a.m. l:ifAI REQUIRED with number of supply and return openings listed per room with CFM's per opening. New structures or additions send floor plan with supply and return locations shown_ HEAT LOSS CALCULATIONS, PAYMENT AND APPLICATIONS MAY BE MAILED TO THE CITY OF PRIOR LAKE, 16200 EAGLE CREEK AVE. S.E. PRIOR LAKE, MN 55372. House Heating Test Record must be submitted with building ~ number ing certificate of occupancy will be issued. The. price of your heating permit rough-in and one Additional inspections will be billed at $35.00 each. before build- Telephone' Address Address includes one Remember to add the State Surcharge on the bottom of this application. Industrial. Commercial & Multi-Family Residential, Heating & AC Residential, Heating Only. Residential, Gas Fireplace Residential, Adc1itions & Alterations Residential, AC Only final inspection. 1 % of job cost ($39_50 minimum) $99.50 $64.50 $39.50 $39.50 $39.50 Lot _ Block Site Address 1\ U-~ Fee Schedule Date Single Family Commercial X Industrial Public " Multi-Family Other CITY OF PRIOR LAKE 16200 Eagle Creek Av. S.E. Permit No. Prior Lake, MN 55372 4-\(D \.0<6 ~ ti9~11 Two-Family TV E 1. 2. 3. Pink Ore Yell. File Ory ConlrKlOr JUL I 0 2fXX) CITY OF PRIOR LAKE PLUMBING PERMIT APPlicant:_&i1=t.. - L~ n Address: Signature: Legal Description: Site Address: Building Permit NOTE: This permit will not e FIXTURE UNITS 1. Blue 2. Gold 3. Yellow Pile Oty Applicant The Center of the Lab Country Quantity Type of Fixture Quantity Type of Fixture Bath Tub with or without shower Rough-ins Dishwasher .~ Water Heater '6 Floor Drain Water Softner ,0 Lavatory (bathroom sink) Stand Pipe (washing machine) .~ Laundry Tray (1 or 2 compartment sink) Sewage Ejector Shower Stall Backflow Assembly (RPZ, Double Check, PVB) Sinks Backflow Assembly Test Bar Sink Lawn Sprinkler In Water Closet (toilet) Other FEE SCHEDULE Industrial, Commercial & Multi-Family (1 % of job cost, $39.50 minimum) Residential, New One & Two Family Residential, Additions & Alterations State Surcharge $99.50 $39.50 $ L..j 11 d. $ $ $ .50 GRAND TOTAL oy $ ~ I 'D ;.--- This permit is granted upon the express condition that said contractor, shall comply in all respects with the ordinances of the State Plumbing Code and the ame me ts thereof. b r ~ -11JI! 16200 Eagle Creek Av. S.E. Prior Lake, MN 55372/ Ph (612) 447-9850/ FAX (612) 447-4~ An Equal Opportunity Employer QLtrtifuatenf Q)ccupmtty L CITY OF PRIOR LAKE 1JBepartment of .uilbing Jn~ptttion Final Permitted 0 Conditional C. o. Expires This Certificate issued pursuant to tM requirements of Section 307 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordi1UUlces. of the City of Prior Lake regulating building construction or use. For the following: liMO Use ClassificatiOll I I Occupancy Type ~ ~JType Construction VN Fire Zone ~gm~ri~~ Ll, B2, FOUNTAIN HILLS ADDITION Owner of Building Site Address WENSCO, INC. 1895 PLAZA DR., CoDlndor', N.... .t Address // /111 D HUTCHIN~\J City Planner ding Official (/ Date: IZ- Date: POST IN A CONSPICUOUS PLACE Bldg. Permit No. 00-0469 N/A C4 Zoning District 4385 FOUNTAIN HILLS DRIVE NE SUITE 200, EAGAN MN 55122 DON RY~... . A-'L4LeM;- (L/~ CDNTRACTIN& 1:0. t DEVELOPIN& YOUR WORLD October 27 I 2000 City of Prior Lake 16200 Eagle Creek Ave. SE Prior Lake, MN 55372 Re: Fountain Hills, RCC #603 Wensmann Commercial Bldg. Prior Lake, MN To Whom It May Concern: Please Ie this letter serve as our notification that all three water lines; domestic, irrigation and fire protection lines into the Wensmann Commercial Building on Fountain Hills Drive, were completely flushed on Tuesday, October 24. 2000. A bacteria test was taken and it passed. If you have any questions or concerns, please contact me. Thank you, Respectfully Submitted, Ryan Contracting Co. ~1,hw~ Scott E. Enright ;J &if) Vice President SEE/cjp 8700 13th Avenue East Shakopee. Minnesota 55379 612-894-3200 Fax: 612-894-3207 TOTAL P.02 P.01/02 ,<;.10 17: 00 c.~.4lI" DII ~ ...A. r..._ 1-1 ~. ," _.... DdIIt .... , ........ saa .1.,. f.. ......... .. "PAXCOVERPAGE FR.OM: FAX": ~f~ 2kJ- 00 ~ Hf.A.t(J,,~~ lOrn · q5i: 447- c.J2.."~. . _"r DA TB: TO: NUMBER OF PAGES INCLUDING nus cova L~t 1t:.R.: 2 · ~. SUBJECT: ~D T~f 1-\, \\s.. *;:~. ~ _~N ~ klAd......... '\ 1l.r':'HIVl -3z> Pll.L~k ~~~ 10 W;fllJt!:Sf;; .j-Atc' , ... .' ...... -.' -', .. -.. S:~-r1 (-J.JfZ,'G(i\ 7-$~;t~~ 1 Foe. 4~ FOt.rnt,~cJ ~ 'R~,..) t~.h'l.trJ..d-t~ <.fOld e,,:I; -J:p I d I{ VfILJ W;~OI~ oJ 1J.Jj'{ 1"JY1r; --- J a~ · IF nus FAX TRANSMllTAL IS NOT COMPLETE. PLEASE CALL OUR OFFICE AT 651-406-4400- THANK YOU! I I -'.' FILt~~ WAS cL,,,c- IO/Z4/ao -t? ~ ~ ~,~tv!I[!(.,'N') ()~ f 0 ~ (,J( ~ ! ( c' '/ fA./ (Y7'--<""-% Of- rc.-Vsttf,,0r::>. Io( 2..1 ?Ie) . ...;.1:100 17:00 P.02/02 TwiNtJ C(Xy WareA'" C~ I Y\.C/. &171ith Ave Sa . HDDkins, Minnesota 55343 · (612) 935 · 355& 10/26/2000 ~",...,." Ry.n Co"r,tldillg 8700 13rh Ave E Slt"Ie",," M" 55379 ItRO:RT OJ WATD ANALYSIS Lab #: 2251 B Ou" LAhg,,,roI'Y './fH'rts these IfIl'ttllyri~tll 'Hulrs, defe,,,,i,,etJ "ft II s.",,,I. r"lce" by CLIENT tJlI J 0124/2000 fro," rite ftJlltJwirl' ItJcGritJ1J: Job .IDa Fountain Hills 2nd.. AdCl ~\c1t1b1 u.... C"liform Stler."i" <7/100 ",1 J~ ~~ Uf_ AlMl,.'r ...... ~1cirw ........ 981'. W... ~iiJ& t..b Cadti..1ieft 1I1PZ74l.l-1 I. TOTAL P.02 14745 South Robert Trail Rosemount, MN 55068 USA EIN: 41-0684554 Telephone: 651/423-1144 Quotation 83578-E ' Customer: WENSMANN HOMES INC. 1895 PLAZA DR STE 200 EAGAN, MN 55122 U.S.A. Job Site: Fountain Hills Prior Lake, MN Date 07/12/00 Job# -"THIS IS A BID/ESTIMATE Customer I WHI2 I Ship Via I -I F.O.B. I Terms I I AS NEGOTIATED 1 Purchase Order Number I Salesperson Reference No. 1 Item Number aty. Ordered Item Description 1 DESCRIPTION ., Required Date Discount % I Tax. Extended Price 06/07/00 N "'REVISED 7/12/00 FOR LIGHTING SHOWROOM* /' SHOWROOM FURNACES: 4- Lennox 80MGF4/5-120 120,000 btu 80% efficiency natural gas, 1- Lennox 80MGF3-60 60,000 btu 80% efficiency natural gas (Office 201) WAREHOUSE FURNACES: 4- Lennox LF24-250A 250,000 btu 80% unit heaters AIR CONpITIONING: 4- Lennox 10ACB060 5 ton 10 SEER, 1- Lennox 10ACB036 3 ton 10 SEER (Office 201). Two condensors located on west and three condensors on east sides. THERMOSTATS:. 9- Honeywell T87F with subbases (standard round) MECHANICAL VENTILATION: Please refer to option sheet - Z.O unit recommended DUCTWORK: PVC transite duct for lower level showrooms. Overhead sRiral for Office 201 (zone one) 'with second zone to lower showroom to supplement cooling. Central ducted returns for all units- located in bathlhall areas. - "'PVC piping to be installed before last backfill lift and compaction. GAS PIPING: From furnace to meters only (meters located on.".east sider MISCELLANEOUS: Vent (10) bath fans, fans by others (5) Combustion air intakes out roof Engineering & design fees included Permit included All wiring by others Two zone auto duct system for office 201 *NOTE: ALL ROOFING By.oTHERS. DUCT PAINTING BY OTHERS. MECHANICAL ROOM REQUIRED FOR:SHOWROOM 130. ~~11 ~z ~ A -H f\ " August 04, 2000 Wensco, Incorporat: ~ 4385 Fountain Hills Drive Re: BV AC ~ The following are the results of the preliIninary plan review for: 4385 Fountain Iiills Drive. Our COlnlnents are based on the Minnesota State Building Code (MSBC). This was adopted with the amendlnent of the 1991 Unifonn Building Code (UBC). 1) A water collection systenl111ust be installed below all underground BV AC ducts. In addition, Under-Floor ducts 111USt cOlnply with 1346.1004 on the Minnesota State Building Code. 2) Provide 15 cubic feet per 111inute of fresh air exchange per occupant. Indicate the method utilized. 3) Provide cOlnbustion air for each unit heater. 4) Provide gas piping support as indicated in the 1991 Unifor111 Mechanical Code. , (Appendix B, Chapter J 3, Table BJ 3-A) Thank you for your time and anticipated cooperation. If you have any questions or concerns, please, call me at: (952) 440-9852. '" Jay Scherer Building Inspector 16200 ~~I~"e:reek Ave. S.E" Prior Lal<e, Minnesota 55372-1714 / Ph. (612) 447-4230 / Fax (612) 447-4245 AN EQ\ JAt orrornUNITY EMPLOYEH ~:16 Ta:Tam Sand , tram: uoug,1aS 1'(. .1VCrSDII LU.LI-J ..I-U .,..,..... I G!:IG &.,,, DOUGLAS R. IVERSON. P.A. 6550 YORK AVE. SO., E~INA, MN ~435 (612) 920-2330 FAX (612) 920.4493 FAX Date: September 2S, 2000 From: Doug Iverson (651) 905-3678 (612) 920-4493 To: Tom Sand RE: WAREHOUSE/SHOWROOM WENSMANN HOMES PRIOR LAKE, MINNESOTA Memo: Enclosed is a revised sketch SK00925A showing spread footings under the opening columns instead of the beam over the existing strip footing as shown in sketch SK00918A sent last week. This change is to accommodate a field request. The new footings should be placed directly above the existing strip footing. Please call if you have any questions. ~:16 To:Tam Sand tram:uouglas K. !verson ~lJJ.c.J ac.u-'T"T.J.I I aYI:i .n.. DOUGLAS R. IVERSON, P.A. Structural Engineers 6550 York Avenue South EDINA. MINNESOTA 55435 (612) 920-2330 Fax (612) 920-4493 JOB~Luf'~"~ pll.laA..l ~~ SHEET NO. S"- OOe. ~C' 8 OF CAlCULATED BY D Il. l OATE q, ( .).~ I~o. CHECKED SCALE Jar!. . .J .0. ~ W( ~. \~ c...... Cew . ~ ~ ~~'t' . . .J 1 t. -. 4l ,-' p, ~ It. 4-~let '-~{p W~~.c.~4 ,.. · '^: · '''-'''IJ.'' ~ let ~.-... , c'AC)'R. % ...c..'c~" ~... -e./It ~ 4\ k.~1 \(. we fa'-''n' 9 94SL e ~It-(.-I(LO" ... -till"" ..,!. a ~o" ~ '..:l II & ~~.. ,.. ,... ''',' .....t14 ....~ 1"4 ~II. 'O.~". · '-' F=T\e '~4"" ~~~" ~1LO lit PAOOOC-lM I ..... !IlIdI) l!O5ll...... t:55 To:Tcm Sand from:Uoug!as ~. lversan lDU. J :u.rJ-....:JJ rage ", DOUGLAS R. IVERSON, P.A. Structural Engineers 6550 York Avenue South EDINA, MINNESOTA 55435 (612) 920-2330 Fax (612) 920-4493 JOB \Nr..U~'-A"L-\ PIlI~L~L2.. SHEET NO. ~k. O~q I & A. OF CALCUlATED BY DR..' DATE q Its I ~ CHECKEO BY DATE SCALE .~ ':Ow C'- "-t.. wa~~q~. ..... ~I C4p fa '4 .... c.... \C).. I , Q 4" I&~ "CotWC- tO~ ~I,I""''' '14 .c,"., eo..;. .,..-.t. TD".. t :-4 ,.,.~ .\0"0.(.. ., . . ... . . .. . e-.,s\. R.. ~4C\' -. c." ~ '-0 ' ---- ~1 1011 ~ ""'-. , ......, August 3, 2000 Genz-Ryan Plumbing & Heating, Inc. 14745 South Robert Trail Rosemount, MN 55068 Re: Wensco, Incorporated 4385 Fountain Hills Drive Plumbing Review Building Permit # 00-0469 Dear Mr. Tom Sands: After viewing your plans, I have made a list of all the necessary Minnesota State Plumbing Code Rules that apply to this project. These codes must be addressed prior to the start of work. With this letter, I have enclosed the list of Minnesota State Plumbing Code Rules from Chapter 4715-1998. It includes the sections as follows: "Soil, Waste and Vent Piping", "Water Piping", and "Miscellaneous." If you have any questions or concerns, please, feel free to call me at: (952) 447-9852. When you are prepared to schedule the required inspections, please, call the Building/ Inspections Department Receptionists at: (952) 447-9850. Sincerely, ~~ y.Q-'* Jay Scherer Building Inspector 16200 B8g~~reek Ave. S.E., Prior Lake, Minnesota 55372-1714 / Ph. (612) 447-4230 / Fax (612) 447-4245 AN EQUAL OPPORTUNITY EMPLOYER All Sections Reference MN State Plumbing Code Rules Chapter 4715-1998 Soil, Waste and Vent Piping 1. List materials used for piping per 4715.0410 and 4715.0420 2. Provide full size accessible clean outs per 4715.1010 and 4715.1030 3. A 4" clean out is required at the end of the 4" underground and on the back to back toilets per 4715.1120 and 4715.1030 4. Provide inspections and tests per 4715.2800,2810,2820,2830 Water Piping 1. List materials used for piping per 4715.0410 and 4715.0420 2. List type and manufacturer of back flow preventers in all locations per 4715.2020 and 4715.2030 (i.e. outside faucets, lawn sprinkler) 3. One water meter allowed per water service per property. Discuss with the City if two separate services are to be installed. Install water meter per 4715.2280 4. Disinfection of potable water system per 4715.2250 and provide test results to the City 5. Insulate and protect any underground water piping 6. Identification of potable and non-potable water per 4715.1910 7. Water heater temperature and pressure relief valve to be installed per 4715.2210 8 . Water meter is not to be installed prior to fire supression system 9. Water supply control values to be installed per 4715.1800 Miscellaneous 1. Provide valve and P trap protectors on lavatories and HIC sinks per CABOI ANSI AI17.1-1992 section 4.20.4 2. Hangers and supports per 4715.1430 Plan review for: Wensco 4385 Fountain Hills Drive (Building Permit # 00-0469) Reviewed by: Jay M Scherer / Building Inspector 16200 Bag'~'€reek Ave. S.E., Prior Lake, Minnesota 55372-1714 / Ph. (612) 447-4230 / Fax (612) 447-4245 AN EQUAL OPPORTUNITY EMPLOYER MINNESOTA DEPARTMENT OF HEALTH Division of Environmental Health REPORT ON PLANS Plans and specifications on plumbing: Fountain Hills Showroom/Warehouse, Prior Lake, Scott County, Minnesota, Plan No. 010293 OWNERSIDP: SUBMITTER(S): Genz-Ryan, 14745 South Robert Trail, Rosemount, Minnesota 55068 Plans Dated: Date Received: July 26, 2000 Date Reviewed: July 28, 2000 SCOPE: This review is limited to the design of this particular project only insofar as the provisions of the Minnesota Plumbing Code, as amended, apply, and does not cover the water supply or sewerage system to which this plumbing system is connected. The review is based upon the supposition that the data on which the design is based are correct, and that necessary legal authority has been obtained to construct the project. The responsibility for the design of structural features and the efficiency of equipment must be taken by the project designer. Approval is contingent upon satisfactory disposition of any requirements included in this report. Special care should be taken to insure that the material and installation of the plumbing system are in accordance with the provisions of the Minnesota Plumbing Code. A copy of the approved plans and specifications should be retained at the project location for future reference. A set of the identified plans and specifications is being returned to Genz-Ryan. Enclosed is a copy of the report and transmittal letter to be forwarded to the project owner. INSPECTIONS: All plumbing installations must be tested and inspected in accordance with the requirements of the Minnesota Plumbing Code. As specified in Minnesota Rules, part 4715.2830, no plumbing work may be covered prior to completing the required tests and inspections. Provisions must be made for applying an air test at the time of the roughing-in inspection as outlined in Minnesota Rules, part 4715.2820, subpart 2, of the code. A manometer test, as specified in Minnesota Rules, part 4715.2820, subpart 3, is required at the time of the finished plumbing inspection. It is the responsibility of the contractor/installer to notify the State Health Department when the installation will be ready for a test and inspection. To schedule inspections, contact the state plumbing standards representative for your region, or call the metro office at 1-800-926-6216, or Gary Topp at 651/215-0841. REQUlREMENT(S): . 1. The storm drainage system must be sized in accordance with Minnesota Rules, part 4715.2710. The following comments pertain to the design of the regular and overflow storm drainage systems: a. Each of the roof drains appear to discharge 7,342 square feet and is served by a 6-inch horizontal leader. Since a 6 inch horizontal leader can only accommodate 5,350 square feet at a slope of lI8-inch per foot, each leader appears to be undersized. You must verify that the storm drainage system can adequately discharge the calculated flow. b. Each of the two systems have two roof drains that combine to discharge 14,685 square feet and are served by an 8-inch horizontal leader. Since an 8- inch horizontal leader can only accommodate 11,500 square feet at a slope of lI8-inch per foot, the leader appears to be undersized. You must verify that storm drainage system can adequately discharge this calculated flow. 2. The storm sewer appears to cross the buried water supply. All underground sections of building drain and building sewer pipe located within 10 feet horizontally of underground water service pipe must be constructed in accordance with Minnesota Rules, part 4715.1710, subpart 2. Fountain Hills Showroom/W arehouse Plumbing . Plan No. 010293 Page 2 July 28, 2000 3. The distance between cleanouts in horizontal piping shall not exceed 50 feet for 3 inch or less in size or not over 100 feet for 4 inch and over in size (see Minnesota Rules, part 4715.1 0 1 0). This shall include the building sewer inside the building and outside the foundation walls. 4. A cleanout shall be provided near the connection between the building drain and the building sewer. The cleanout at the outside wall may be inside or outside of the building, and shall be made with a full "Y" branch fitting and shall extend at least 2 inches above-grade or finished floor, except that the administrative authority may grant permission to use a flush cover (see Minnesota Rules, part 4715.1000). 5. A cleanout which is easily accessible shall be provided at or near the foot of each vertical soil or waste stack and each vertical storm water leader (see Minnesota Rules, part 4715.1 000). 6. The sanitary drainage system must be sized in accordance with Minnesota Rules, part 4715.2310, subpart 2. The following comments pertain to the design of the this system: a. There appears to be eight drainage fixture units discharging on a 2-inch pipe in the SW bathroom as shown on Sheet MI. Since a 2-inch horizontal drain can only accommodate six fixture units at a slope of 1/4-inch per foot, this portion of the system is undersized. b. There are two mechanical rooms with a floor drain, a mop basin, and two water coolers shown discharging on a 2-inch pipe on Sheet MI. This adds up to be seven drainage fixture units on a 2-inch pipe which is undersized according to the previous part a. 7. Numerous fixture drains are shown with sanitary tee connections going from horizontal to horizontal. Changes in direction in drainage piping must be made by appropriate use of wyes and bends. Sanitary tees are not allowed where the direction of flow changes from either vertical to horizontal or horizontal to horizontal (see Minnesota Rules, part 4715.2410). 8. Assuming a maximum developed length of pipe of200 feet and a building water pressure at the meter between 46 and 60 psi, and using Minnesota Rules, part 4715.3800: a. The building supply line shall be at least 1'l'4 inches in size to the cold water distribution branch serving the second floor bathroom group. b. The building supply line shall be at least 1 ~ inches in size to the cold water distribution branch serving the second farthest bathroom group from the meter. 9. The direct connection between a potable water supply and the lawn irrigation system shall be provided with an approved backflow preventer in accordance with Minnesota Rules, part 4715.2020 and part 4715.2110. 10. The combination fire protection/domestic water service shall comply with the backflow protection requirements of AWWA-MI4, Chapter 6 (1990) with the exception that the following statement is deleted from section 6.3: "At any time where the fire sprinkler piping is not an acceptable potable water system material, there shall be a backflow-prevention assembly isolating the fire sprinkler system from the potable water system." 11. Faucets equipped with threaded hose connections must be provided with approved backflow preventers. This shall include the mop sink faucets. 12. Equipment used for heating water or storing hot water shall be protected by approved safety devices in accordance with Minnesota Rules, part 4715.2210 and part 4715.2230. Verify that pressure and temperature relief valves exist. Fountain Hills Showroom/Warehouse Plumbing Plan No. 010293 Page 3 July 28, 2000 13. Water heaters must be installed so that they are readily accessible for inspection, repair, or replacement. A water heater with a tank capacity of 6 gallons or less may be concealed in a ceiling space provided the water heater has been set in an overflow pan (see Minnesota Rules, part 4715.2240 for requirements). 14. All underground sections of building drain and building sewer pipe located within 10 feet horizontally of underground water service pipe must be constructed in accordance with Minnesota Rules, part 4715.1710, subpart 2. 15. The copper water distribution piping must meet ASTM Standard B 88. 16. ABS plastic pipe used for the drain, waste, and vent system shall comply with ASTM Standard D 2661 or F 628. 17. The water piping system shall be disinfected in accordance with Minnesota Rules, part 4715.2250. 18. The plumbing system shall be tested in accordance with Minnesota Rules, part 4715.2820. This shall include the storm sewer located within 10 feet of the buried water supply. NOTE(S): 1. The scope of this project consists of constructing a new office building. Installation includes five water heaters, five mop basins, five water coolers, two kitchen sinks, and bathroom fixtures. 2. This approval does not include any part of the roof drainage system. The rain water leader design must be submitted to me and approved prior to installation. 3. The building is served by new municipal sewer and water services. Authorization for construction in accordance with the approved plans may be withdrawn if construction is not undertaken within a period of two years. The fact that the plans have been approved does not necessarily mean that recommendations or requirements for change will not be made at some later time when changed conditions, additional information, or advanced knowledge make improvements necessary. Approved: C~4:~ Corey A. Frain Public Health Engineer Environmental Health Services Section P.O. Box 64975 S1. Paul, Minnesota 55164-0975 651/215-0844 CAF:mak cc: Project Owner Genz- Ryan Mr. Jay Scherer, Plumbing Inspector Plumbing Unit File ~ E @v-Qf) , ~ ~ /q--: , (Pf&<..- /fI/ft/.. , fIp<J ~ t~~L--~~ ~~ I4e. .4/~ rC?r oN' IJt 6~ L-4"e::; Go ;~-, /l-r.t7-4 f;;; U - II. - 7000? f4rl,...l~l'-"~ (N ~,- o(f(~ ? f.AJ(~.~ c;er ? r CA./({ i... ~~ rP,,-O IJvDv ~~,//o..''"I..J'-~ tAPr-~ tS- G{1r~,,-. ~rz-O~-,- ~"u'-C> fr1 ~. ~L6"? F1 tL W-0-t i If,hl-t) 4u145U IS Vl!iNr -9-r,e.? f -5 J F-ld (C'"$ ) f - 4 F~/, F-2- 6J, q~9 ~ll ) t Ae? 10 I Z5 flit . ~ ft;[; (/() ~ I 31/2.:;:" " C:6' . {p6N-Z: (p.51--l'Z~- / /4-4 100t1b,~ CAu.LD loA-~;.) L4t,~, -~~Lf. ~s t1~/r1'~ ~IPCG~. 1(!)/ II z. L,:> :5 - (00;<15 00y~ Sf380 ?::,? ~D 5/00 /Zo 60 y $r.; /30 Go ~ 3)" L I 0-.::> /[tvg 17 10':;; /1- TA-~ ~ I't:. fe,i.1l/ft. - t r I 0 f FL Or+;Co- ----~511or7-!~ /; /sr 30 : !.-:z~4:. - 'Z->>(p~a~ z.S-oc.G Z~ \ / \" /' / ~--.., -1-2000 11:41 P.02/03 . -:1- -.- DOUGLAS R. IVERSON, P.A. 6550 YORK AVE. so.. EDINA. MN 55435 (812) 920-2330 FAX (612) 9204493 FAX Date: October 10. 2000 To: Tom Sand. (651) 905-3678 From: Doug Iverson (612) 920-4493 RE: WAREHOUSWSHOWROOM WENSMANN HOMES PRIOR LAKE. MINNESOTA ~iC'.. ,(' Memo: Enclosed is a revised sketch SKOO92SA (rev dated 10/10/00) showing the right pier cemered on the column and the footing dimensions mirrored. This change is to ac::eommodatc the as built condition. The new footing should be: placed directly above the existing strip footing. Please call if you have any questions, ....-2000 11:42 P.03/03 DOUGLAS R. IVERSON. P.A. Structuntl Ensineen 6550 York Avan.. South EDINA MINNESOTA 55435 (612) 92Q..Z3JD F.. (&12) 920-4493 a-W.~"y~~ PIh-" f.,,~ !lHZna. S It. ftft6 ~ e 0' Q&\ CllTE ~1:3.S"~o ..- . CllLa.a.a1l!OWt' --- tA/SL~ .~, QtEC1IIDIIY ....." "" ~100 5CM.E -![ .0 ~ ~~ . ;- , .......' Ie.." 4Y \ PI &11.- 4. M-L. ~,,-,- << ~~6< \.)~ ",rr ~ . - " 141~"'''4 C4_4l .4......~Y:t C...A. %..t"'lD~ .,.. '3/." ~ "-~I" 6-,-"'- '9 84ne~al.'~LO' '"'... ,..-&u.. PlEa t ! T1~$ ~ ~. ~--.. '~~".Dl. 8M I tJ-ro E.i..' S't'" H-t. ~ ~"c..\4."I:a. t..) L t"~. "'..." · W't. 16') ~D .... In.''''' OA.. AtPPtlAtI.. E Q\I"\.. . , . " 0 At ~~ 1"4"1& s.~.. IlL - ....tr._I__'W.._ TOTAL P.03 CITY OF PRIOR LAKE WATERMAIN PRESSURE TEST /j/&1f,#1/'tH BUJ t;D/N7 / ( PROJECT NAME H5UriTItIr1 r),L-v? DATE 7 g/O{) PROJ. NO. 99- 31__ . / ' CONTRACTOR RYAN SUPERINTENDANT~"t/II\j INSPECTOR .JGY"F bY 61'1 ~ DESCRIPTION OF TEST SECTtON 7~~V}L,r;; WoF TO BUlL- 'DIN?, DATE OF TEST NUMBER OF TEST 7/J7/00 / I Z,'b3 lENGTH OF TIME INITIAL PRESSURE />2 1;;;- FINAL PRESSURE __ / :;-Z" > ~RETEST __ DESCRIPTION OF TEST SECTION DATE OF TEST NUMBER OF TEST lENGTH OF TIME __ INITIAL PRESSURE FINAL PRESSURE PASS I RETEST DESCRIPTION OF TEST SECTION DATE OF TEST NUMBER OF TEST lENGTH OF TIME INITIAL PRESSURE FINAL PRESSURE PASS RETEST COM MEN TS : . / ..J 04:20p Renee Swan (651) 747-1441 p. 1 AIR FOR LIFE, INC. 2901 SE Ath stn!et Minneapolis, Minnesota 55414-3330 Phone: 612.331.8286 Fax: 612.331.8240 .- ii !",:.'\ " i I ') \ . Ii I , I, 1~1.13~ ~~'i RK To: Bob Hutchins I CITY OF PRIOR LAKE From: Dave SWan Fax; 952/ 447 - 4245 Date: 10/12/00 Phone: Pas-: Cover + 1 Re: GRIPPLE HANGING SYSTEM cc: J Mr. Hutchins, The following information on the use of the Duro. Dyne Gripple Hanging Systems is submitted for your consideration. You will find the manufacturer's installation instructions, product description and SMACNA standard written specifically for this hanging device. Should you have question, or wish to view a sample of this product, please feel free to give me a call at 651 I 747 - 8000. Mr. Todd Boyum at Genz-Ryan is the contact who is in need of your response. You may reach him at 6S 1 I 423 - 1144. Thank you for your time. Dave Swan ToO Free 887 I 331 - 8286 Fax: 651 I 747 - 1441 B-mall: dsw8n~alrfor1ife.com ..I 04:20p Renee Swan (651) 747-1441 p.2 Built for reliability. Built to last. The Gripple utilizes a double opposing wedge design to achieve an efficiency of 100Q/o at the strength of the wire cable. And once the wire cable is secured with a Gripple, it stays secure until you want to release it. Zinc Alloy Body Sintered Steel Locking Wedges Stainless Steel Springs PART # DESCRIPTION SIZE W,L.L,* PART # DESCRIPTION SIZE ft ./spool W.L.L. · (Ibs,) (Ibs.) .-----.. --.- . ....... 30020 GRGO-2 GrilJpl~ - Buill 1/16 - 3/32' 11\0 30200 WC-2 Winl Cable 1116" 500 It. spool 96 ...... ..--.---- 30023 I GRGB-4 Gripple - BlIlI( 1/8' 440 30202 WC-3 Wire Cable 3/32" 500 II. spool 1[\4 -;-..--. . ---. . ..... -.,- .-.....-..... ....-....... ".- --'-"'- 30026 GRGB-6 Gripple - Bulk 3/16' HHO 30ZD4 Wt;-4 Wire Cable 1/8' 500 It. spool 340 30029 GRGB-B Gripple - Bulk 1/4" 1200 30206 WC-6 Wire CClLJI~ 3/1 G" 250 It. spool 840 i '-..---....... .-.---..----- Bulk I'~cks - 100 Per Carton 30208 WC-8 Wire Cable 1/4' 250 11 spulll 140U IMPORTANT: Gripple and Wire Cable each have working load limits which may not be equal. Always use the lower of the two working load limits, HANG FAST PART # DESCRIPTION SIZE LENGTH (fl,) W.L.L. .. (Ibs.) "---- "'_"0- 30102 HF2- 5 Hang Fast 1/16' 5 It. 96 30112 HF2-15 HallY Fa~l 1/16' 15 It. . .. . . ....... '---"--' 30118 HF3- 5 Hang Fast 3/32" Sit 180 30124 HF3.15 Hang Fast 3/32" 15 It. --. ------.----.,.-...-. . ........... ._-------~. 30130 HF4- 5 Hang Fasl 1/8' S 11. 340 30136 HF4- 15 Hang Fa!;\ 1/8' 15 11. 100 Gripples and 100 Preformed CJbles Per Box .Working Load Limit (5:1 Safety Factor) Wire Cable Not Included With Gripple, For more information contact YOLlr local Duro Dyne Distributor or Duro Dyne Regional Office: ~u RO DURO DYNE EAST DURO DYNE MIDWEST DURO DYNE WEST . 130 Roule 110 3825 Symmes Road 15005 Marquardt Avenue Farmingdale, NY 11735 Fairfield. OH 45011 Santa Fe Springs, CA 90670 516-249-9000 513-870-6000 562-926-1774 Fax: 516-249-8346 Fax: 513-870-6005 Fax: 562-926-5778 ) @ 1999 Duro Dyne' 4/99 ..J 04:20p Renee Swan (651) 747-1441 p.3 -. .,.,..... .. -- · '::J · ..... ~. · ."" ~ · · · ." · ~ ..... .. · ...,. " 5 Easy Steps ~ J ~ Step 1... Thn:ad the tail of th. wi,. rope through (or around) the anchor paint (_,-hook or pur.in). ~ Step 2... The,.. pass 1ft. tail thfDugh DIe 'erruled .oft ay. and p~lllig"L Step 3... Now pu." the blil...nd through ofte chann.lln the Grippi. Rop. Grip and pulJ a requisite length through. , Step 4... Pus "'. tail..end throUI" (or around) the bracket or fixture on th. DbjeC110 be suspended. Step 5... Return the rope to ua. Gltppl. Rope Gnp and push thrvush Ibe aecond channel. Pull the fttQulted rength 01 ntp. Ulrough to rals. the abject to t"e Clesintel height, Helpful Hint... Installlh. object low and adjust upw.rdllo the desirect I.ve' by pulling the tOpe thrvugft tft. Grl,pl. Ro.. Grip using the tall-end. ..GII'II"~' ........~~ Gripple- Rape Grip and Grippl.- Hang Fast ara regiSlered trademarks of Grip~le Limited. EnglnrtCS ttIf# ~.J 04: 21p Renee Swan (S51) 747-1441 p.4 ~ ....,Mo'U......... .....:J~_.....,..,'_.40................~"".1.....7.......:.~..- .~. .....~~ "~'. '-'-.- oJ 04:23p Renee Swan (851) 747-1441 p.5 OCT-03-2000 15:32 l::Jut.~t< I NL . Gripple and Hangfast Minimum Wire Rope Hanger Specification Tables OJ.a::. ,,)10 ~Uj;, , .. LI.J" LJ-' Rectangular Duct Maximum Half of DUd Perirl1Eter P/2 = 3D" p/2 :: 72- f(l2 = 96- pl2 = '20" rJ/2 ;: , ti8" IJ/2 = '92" : 10 ft spacing; 8 It 5DQdng . S ft sDadna 4 It spacing ; f pair : 1 Qair , pair , pair 1/16 '/16 "16 1/6 liS 3132 3/32 1/18 118 1/8 3/32 3132 J/', 1/8 1/8 3/32 3116 3116 1/8 1/8 3/'6 311& 1/8 118 Round Duct MaxiMum Round ~'D. i 10 II specing; 8 ft spilcinG . 5" sDacrng . 4 ft sl)ac:inQ OJameler , Pilir 1 pair 1 pair ---!..~a'r ,Q'. 1/16 1116 1/16 1'16 18" 3132 3132 1/16 1/16 2'. 1/8 3/32 3/32 1116 36. 3116 J132 3132 3132 SO. 3/18 3/16 111 1/8 60. 311<<5 311 f5 1/8 1/8 84" J/16 3/16 3/'6 118 Notes: 1. Tables are calculated using a duct weight of3.656 Ibs.lsq. ft. and nannal reinforcement weight. 2. For special applic:aaons refer to the follOwing table for working load limits: 1/16n Wire Rape 3/J2n Wire R.ope l/S" Wire Rope 3/16" Wire Rope 961bs W,L.L. 184 lbl. W.L,L. 3401bs. W,L.L. 840 Ibs, W,L,L. 1116 - :31:i2 Gripple Rope Grip 1/8 Gripple Rope Grip 3/16 Gripple Rope Grip 180 Ibs. W.L.L. 440Ibs. W.L.L. 880 lbs. W.LL. December 1 Sth. 1998 ~OJ 04: 24p Renee Swan (651) 747-1441 p.6 Applicable Smacna Standard. 4,2, 11 Manging $yJtem Sele<<ioll The selection of ~ hanain.IY"em should not be. taken li&ht1y no' orly because it involves a ~iJ;nific;.Dl.'\t portion oftheerec:tioft labor,. but 1110 ber.awl: an inade'J'lle hailging sys&an Qn be disas- trOu~, 10 any multiple hlDling 5Y..n, the fitilure of one hUlser truams th., load to adi.~an hang- ers. If one of these r..il, an even IfC&tCI' load is transferred to the neJCl The nsalt is a c:aS&:adillg failure in whidl an enrire run aC duct _pt au, There aft: many ttanpr lltem.lives, especillly in the upper attachments. Besidd structural Idc.."CI\lac:y, the conttractor"a ehoiGe oflulnliona systa\ RalIt also ,~c inlO KCOuat the pani~u)ar5 of the builcli.nS structure. the skiDs oftlu workmen.1hc availability oftooliDa. and the rec::oml1'endltlons of the fUllmer- lnanwacturcr. .Bcause of the Ie vuiablc:s.. it i. sug_ted ,hl.\ the hanlin. syllem be d'f conttactor's choice, Suggested 'specification: All ductwork and cquipmcmt shall be suppor\ed using wire rope cahill!. All wire rope shall be! ,erminated usin8 _ device wida an U1tima\o Braking Slrength (lJ.B.S.) of at leut ~ times the wire ro~c pUblished WorkinS Load Limit.C:W.L,L.) ~U't rope ,hall have a \J.B,S,of 5 time, tbe published W.L.L.. Ware rope with preformed loops 5haU baVI: a (J.B.S. of 11 IC&S1 4 limes the p",bliShed \V.L.t.. .Pre!onncd wire rope loops shall UI~:1 thimble and sleevt. construction. Wire ropn shall be ofrhe siz~ and spaced per manufiKtu~s printed Ipea&calionl. Wire Rope and Rope Grip shall be al suppliad by Duro Dyfte Curporation fllllninAdale, ~cw Vork. R\''''-:~''.ngular Duct Hanging Table Round Duct HaIlging Table ~~ -.nil f'_ : ~o It o.;.., ~!II!!iIIlQ } ~. Uiiara,' :. ...~ ~I\l!~ I Ci........' '....,~..I!!!: 1 _II . , ~r . *, . I-- ...1. _I.~ ",. I ~".' ., ..!~ ~r : ~ ~,'111 I '/11 ~~.. I;: !ti= . .~ ...: -- _I~" .... 'CI' _.... . IV ! "'1.. . .__ ".., ". ._~.---,' .,. i )1.1 t JI'US : .. .,e u, a-". Jt,e.' ~~I .1 .:'!.111 "t 'N(\te~~ 1, nbles. are calc;\llatccl usin. a duct 'IWeigllt of') .656 tbs. / &q. ft. an' nQrma' reinforc.ement weight. 2. for speeilJ applications refer to sp.:cific&lion lab'" of woliWll load 'lUraits' TOT54L F.02 ....0 04:24p Renee Swan (651) 747-1441 p.7 U'w I t,J..J '-UUlJ ....,. -.,'" ",., I J..,_ 'v vv.... ,-' OF THIS PUBLICATION ~ i. \ ACCEPTANCE T~.~ ctaC\lmcat or pv'>>lica'l,n is J'lJ'lred for volunlllY 1;~P'lE'Icc...,d lIS~ "ilhi" the limilatioM of ~~ication c1cfinrd herd,,_ anti .,"._iE.e as dla.1: adupli"S it QI' .pp'~i". iI4..... 'PPPOl'rlate. Ilii hDt. ~Dfew IYlftdlrcl. 1:s lDP1:cltion far I specific project is eoncinlCl:' on a .tlil".r 'If O&hCf .,,'bori~ ddi"iftl & $,ceifl.:, un. S~AC~'" !Uu. Po" I'tt'NI'I)f' aut~DritJ m polia:: Dr ~nrDrcl: """'pliance with lne con,.nu or.~il dotuancnr D~ p\lbh~.~iD" 11'4 it hi) 1'10 role in art)' rcprnl;IItat1DM by OUll1 plni~s dlar Jl'CcifiC' CQl':1por.~It" MR:, in f.~,. in ~gM=-'iafttt _i'h i\. 2. A.-MOMENTS T~~ AnociatiO'1l may. treml'lIlt lotimc. issue fonnal if.\Cf1)rC\lInivnli Or inlcfim &me."tm."n_ wh.,hun bt ah1lniflca"ee belWeen succe!~'v. .dinD"I. f 3. ., PAOPRIETAaVPRODUCTS SMACSA wncoura,er technolGcic:a1 dcvelapmlnt ;,. thf h.,rcr.r Or imllntvinlL tft~ i:tdus['1' (or (he p"bli, benefit. SMACSA. cs."c" nOl, !I\JW$"n. cn.one ,ftCh"i4y.a1 ~..n"f~c\,,'uS or p",d~ctl. 4. FORMAL INTUlP"&TA'ftON ^ (0'1':'''' .ntcrprct.'ion ofUII: li\c:r.' ,...t "CtC.l" at Ihl illlenl af,"~ t~t.ni"al c.D"'l':\inee UI,,;i~\&' with ~hr daClImf"' C\f p","ticatiOlt is obuiA"Ieon')' 8ft .". bl<<il .twrinen "titivn. ,"",sse' &0 ,,,. c:alllllllUce s~d senna lhe Auaci~ll"f1" n.,iorwJ office in Ch."tiU~. Villin,.,."d sllb~"uc"t n:c:~ipt :tf' a wrinen "'poMe "r."if~i", the sppro...~1 Of t~~ c.haift'ftil\' o',h. commi\:cc. In tfle .~.... 'fUll ft plti'ioMr ha., a sytt,tan~i"c ~,s.&n;~m~\ with lh.~ i"tc",rctatiu". .n appeal "'.Y be fU.4I....i',.I"~ Tecllftiu.I Resources eo",",itlet -"i~t: hit tc:chnical D"ln~ch, ~'pvfts.i~\1:t:-. Tht n~qucs' mU'1 ,c:~~'" to . Ip::.=1f1c,Uy jdu",ft&:d pomon oflhc. iGc\lmc"' dll' does not i"VDJ"~ p\lbl'st\~4 ,eJU ...,tll~h pfO...i4es the rrc;uc~'ed j nf'aMl.tieln. 1ft &:('".,.1"'"1 ludl teq"UIS. :tu ^SSOC\3C'Clft will ftot n:v lew or j~,t. producn Dr CQ1':'pa"~m,. as bciftl ir. compli~cc with tM dacum..n\ .' ,,,bliullan. Or~1 a..,,1 ",,,iftl!'ft i"'.rr~Utio..,. attlp....i!liC attlained frOfl"l anyone aftm."d with ,,,. ",ss"ci.ti~n a~ '..noffici.'. T...,s 'fO~~dt.lr~~ dOI!:~ nol Fn:.vcnl ~"). c:amm,nu c:t\a'nn3t\. member of VIe co",mj,,~s, or II." 1,11 son fro", upr".."& .I' o~i".iDn an ~ pI'&wisio:'l w;thi" ~h. CC'C:"lfICnt. prtw14.:d th." sue!' pcr:\of\ c.11&,ly Ntn 1M' t)ac "piftian '$ pC"~Dnal.PI" ODeS nol ,e:llruen: an uffi~ial OIC\ of Ih~ UJOI:'~tiDn if' ~n)' ~3). ~"C i' r:hnuld "ftt M relied ft" ~, $uctt. ""e bDard Dr D,rccl.vn or SNA~,' .sb~U ,,~~ ~.lJ1~1 Jvct:o,il)' fDr jn\~~n;w,i~n ~r Ih\1 1Illftdllrd with l\:Ch ,...In Dr prendurcs ~ Iha:y ,"I~ adopl ror pmc.~si,,~ "Ift&:'. 5, APPUCAnON A"1 Slan4arlll cOn\ai"ccl in Ihis p"blic,lilln wtrc IJndopc:d usinl ,~h.ble e".i"~et';ft8 princi"'\l :al'ld re!ltlrch I:'lul' ecft~lJlta,i.n wi.ha.mlinflnn.ti.no,",",~.'ra"" manl&Fact:.lrtrs, tilers. tcsli".,.boratc;'ric!.pll'ulvthCI1 h.yin"I~~,.li~E:d ~xpe'i~nc:.. 1lte) ..rr ,ubjct:l to rey;,i... :III fuMe, t!'!(pe.rirllel: Me iftYr\uptlan r.\~)' show" MUSSOV)' O' d~s'nblc, Cun~tNc\iD" OI"d precl\lcb thaI com,l)' .,it" t"ele S,,,,dw, wilt "01 "ff:tSAnly l)t .~ceptabh: if. whe" e"'_l'ft'!\~lJ ~"d 'C'~lcd. .hey are fO\l'''{ to hive oth~, fe.'\I"''' ""hic.h .",pai.. t~lI: ruult c:."'~mp\a'~c by lh... req"inr"'~nh Th. ~nl:et Melt\ Al'ct Ai, Conditioninc Co",r,clan' Naban.1 A",ui.,ion and olher to,,'ribulors as,...,,"c "" r~Jpgniibilll~ s"d &'ccptftO lilbililY forl"c appliualionofttlc "inc,p~eJ a:-ICc;hnlqlis;;r.~or".inC'd i" 'his p\A,Jicalion_ Authori:ics -:onsidtrint ~doptial\ ot'$Il)' !l.Qlld~rcb ~Dft(alfted herein 5hauld rnoir:w III reder.l. )t~I~, locallnd C""UtC" re~yl~rion5 :l,.plic~blc: tG spe,ific '''NII.cions. s. ReplaNT PERMISSION NQn\:~~""Jin_ ro,al1,.rrcc pc.nataaivll .. ~d \0 ,ovt:'rnrDelu and pr;vlm:: sector sJllrcjfyiJlG al)lhDril;es I" ~,.rad~,: 1111.1)' aft" COlts'N~io" detatt, rau"d tte,eifl in lItei!' spec,nClcion, and CClftt~i1IC( dr'lwincs pn:pwI:~ Cor rcc.:ip' of bidl Dn nc:wc...n,~ctian uuI n110V~fiOft wort w,thill me. U"Ii~. Satel:anG i'~ len-Harlel. "'lvidcd thai die lIIaltri;l CODilrd l) u~ahercd in Ivtslar.ec ....d lhat lhoe rc",04"~r assumes alllilbill:Y rop ,..., Spec:ifit: eppli,a'ion. inclwline colTon '" rtprodUG\inn. 1. THE SIIACNA LOGO Tin. SMACNA.lo,ca i.c r~I'sl.red... m."'bef5hi, identification mark, The: Assact,ciM prw~crihn Kc;cpublr \&sc: of lhe: IQIII .nd ~.1lpl'elSly forbids the VJC nfil Ie reprc"ftl."Yl1tilll other nlllJ1 p.,t:nic,fI armltntbcrship. "a~_uion bf n'~tr.tKn"ip IncJ -.a~e ., \~I' 10&0 ir. a" WIY ~"ftsti'ules Of n:~tI;U ~~ ...C~ A. appr,,,.t Or in)' p~v"t. m..U\Od. or :om::>>an\'1l\. f'unhennon. c.a",,,l:~"(t nf .1"1 ,\1ch hem "",,, S\lntanSr. publilhcd or "co,,,iud 11)' SMAC~A is 1'\01 in~\a.tl:d by prucncl: of UU! lnln. -.--, vi HVAC DUCT CONSTRUCTION STANDARDS METAL AND Ft.EX'.L~ -- ."""\ ( : ..,.,.~:. . :. ~..... 04:25p Renee Swan (651) 747-1441 p.8 4.1 HANGING AND SUPPOR11NC SYSTEMS 4.. 1 .1 $04.0 "...,i,..,.... S",l lIli' ~ .......Iar, aftG nil ovlllftftal _11 ..1 .. i....1ed willi sup,," sylltms indiCllrd it' Tables 4-110 4-3... ,.pm..1 'o~. They shalt B~ hutalled IS rtClviftd to m.tnraill .,ianllllml. HDrizon&al duclS .11 ~YC a .ppOlt within lWtI fttt (0,61 m) .f each .,~ ~"d tMtJ\il\ four flel of neft Innch inlDneaion. (Upper IIIIKhlllcnts to :nruct\lra s."taU lint 1ft allowable!OId nut IDOIt daan v...roll1h of"lIte fail\n (IrDortal) JurI bur are 11.1 limited ro 1h~ lP~ci fie mcflDcb shown heR. ~ ...2 !~ COMMENtARY 11'\e dIICt hUP"II)Slelll iacD",polllhaftbrwciclftC1\u, die upper aaehn\eftt 10 .. auildllll. die hanlef i\lclr. aNt ~ IOWflrsltl&:ltmlrtt to d'ldtlct n. ft\MU~_"''''.s load ..in., ancI....,auon clara should be foU'I'" tor :all ckvilZS ~d I'fWeri:sls. 4.2.1 COnctete l~ C'Jm:n:1C i:ucIU..1IIt b8 in$laUed be&r, "'~ "1IC",\e is poured. TMy.. __ prilft.,;')' where U\I duct 'IYOUl is simpjc and lItcrc is c""1h lead amc to dc~rminc .ccuraa: plxCtIHIU. The sitftJllea iftacrt i, a picas Df been nl' bar. MIDufaccurn inscrts an .n.illlble individually or in lone IcnlV.l; Ihc latter SIe len......" used *hc:rc IIIIDY ban... wil' be ......Ied In . Sli'ilU arta" or whsr, ind~idua' illHl'lS cannDI be prwcisC'ly "poncd .1 ~ lith~ "I pl,cinC ,Iur c~. 4,2.2 cone.... F.....,..... c~ fufl:Mn ~ illIIaU" aftcr dll: COftCnM has been paumt 3ftd the fomallavl bee" taftGval, '",fir apfAicdiOIl aJlows....lle.i1tili"..CGna1:DJ inMr\J bccaue Ibci: euct laDlfiGft CIft be det$minlll..r .11 i~1 ~ ~ '11';0111 irides' ....,. Mve bee., CDol'dildill:d. Th.cr~ arc uytr~1 ....ialiol\t of powder-actuated fWeft'I'S, ~ichlft,IKri"Y ....._"Cc....' That fUf&l'Icn should nor be UllcI in c.wn ""IWei,1e IIpt:ptc nD"",'cs. or ift I'.. lea tl\u 4 indlel (t D1 rMI) thick. ~nl Wftcmc -Q1DIS -.td be mW .r Iltel. NOIItcnvllt anchors__tICC, -W.YI~M. Herla for apIDItiIq ..~ IWC drill.. either by a carbick 'it . ~ r-. em die fuIanIr i~r. 1k cqlIiKl~Dn shicJci is "'I",'~" drWiq it Into die hD.lII1d~dilll it with "- .aical pl~l- 'n.c ~ian Bait is a t\Jhtet cMr fastener. Powd.....,..tA tilsltftCt'J ~,. ?O&9UlOf fbr 1..~lcr~, 4.&.3 Structural 5t'" Fasteners s~.....a tflJftofbeJm ~lnrlpn~1l'Vlilsblc:. $grnf Jh~uld bellied wlrlle rewaiftincolip. 'crwdcr-Itt'~lcd fUtenel'S mv.lso bcatlCd un steel, Welded",.s 1II11;e install~d un. 'plCi.l weldinlar.lipm.nt Ccnain man",t.acNred dc-as Chalarc4ln"",.CO dtc ftMp:wiJlIIlpl)On ti!ber a roil or a band type hanp, ..1.. Cellula'...., DIf.* MIft)' office Wi Idiftll arc 110" wil' ...u.. ~.n\aIJr SIft' dtd: lhal cill'fies lite .1~rrie.1 _ c:ommu"it.llion sy..... :&". 'I CClveftd Widl COlICretlr ~II. 1"be wirinlJ in Ilk ..na and t~ c:tRICI'CtID a.bowe the deck prwcJudr .he' UK of f'uIe.n.ft:. sa ~ shea metal sm;WI. ,hal mUSI picree the Met. Some m:aII"o.e~ of .,,,. ~JlC of deck now offer I" ift....~ ""'eine s)'.lc1ft, I" cases \V~ \hete arc ,., inll:8tl1 ...cers- .. :he required ht)."'Iilll poi"". Uta) Ih~ rod .)f stnp haft." before CDIItFelr plK'Cnlcn-. or Iftl'lSlI W4rlcSe4 saaclsafter -:o"e:-a.:~~ platCftlh'lt, Jft .n c:ara. ;:he ..per al'LKhmtftU fO rtlt! dedi... tfteuld . il'l plitt bl'ro~ 1hc IPphc:~,ior. of liropruufinc rna1Crials, .,2..5 Upper ADchm.t Uppcr.:aII&Chmanr 1MIhod:s 5Isaukt be set"_ wi!J\c~. ^ _cty factar of. or S .:bucd on uki",=* ra,;u,.) is. pr.wr:UQi .weN il ClIII lac 1bownlMt few unpmtiC'lablt v:arlatds ex.S'I' and dial quality con"'" " disciplined. 11.1.1 ~ Hangers HlDlen arc UluIll., .rri~ of plvui.s Stltl 01 toM" ,..1 rod. For haaccn M_ or ~ s1Rl rod, '* UiI~1e4I M!-taUeII sr.ml .!~cp! wkrc the '1\S!atbtiVl1 i. j" . corrosi~~. wherr canos",n is ~ pubic",. hMlCr.... .uld tJc cICClnl-p'v.i,.ci, all~ rArad rods or n...dipptd plyuizaS rods v,i1h ~C'ir ~ ,.ill"IIi after il'lltaU:ation, ~ HV AC Duct Coll.uvatian Slandllftl. ....,..... f'1..lbI. . s.cond Editlof' .. , TOTAL P,0S P,01/05 -2000 17: 48 CIIIIItNilO4IlkJ.r4" ___I. ca.;ab4oft,. - ....~ . ...... .......MNS5D2 ilL" ',to . 111"""" fa o - kepq "FAX COVER PAGE . rmD ~Cf? ~1~~J' - , (' \ :" i OCT - 321m' i ! -- SUBJECT: Fouo-L~ tt:.l~' ~ + W{l\d .:re.~-\-. ~r~' :P~f"~ 5 +L" - ~~ ~A-it1- M(,~A.l'A -Per 3 -h~~~l~~' J. ur-G~ ~ I ~ ""' .1? l.a.Ase (" A..ll ~~. IF THIS FAX TRANSMITTAL IS NOT COMPLETE, PLEASE CALL OUR. OFfICE AT 651-406-4400. 11IANK YOU! I J .2000 17:48 P.02/05 r f t W-O' j, Yf4 r 3fJ-d J., , , I I I I I ~. -...... I 7671 Till ......-....- - - ~ Ceil. Phone . Fu' Faa:' ~I_t 11-lIt 1I1~' .I~ ,1-4- ~'-7~' 4~~ ~~ ~dj .RIA ..- -.$ ~ ::R Q JS , :i -- - JJq S5 &3 ..H~ ~ to --. ~~ JlqA Jjq i ~ ~ Jrq "lilt' ... ~ ~ &..n ~ l.2O ..n , .a - :f ~ J21 I I ~ ..122' ir N - ....-. lr.Kq LD 1B en ~A .!8A IlI:S &'.,. I!l ~ , , - ~ ~ - - L.I.J I I ~ -. _._.~..._.-.. -'.- ...:.. -~........ ~s rnQ... ~lti en ~ ./ -::=_~ -~ Q SJ " : ff'a~ ....Js ..c: :x ~ <'I ~ ~.u ..J C1.. 9 ~w I-i!: ~ ....J ~ .2000 17: 48 z o t- ~ to ..J ~~ U.l u t:UJ o ':N tn ~J~ - -~ -~~ m~~ -1, a..~ ~ td o -1 < tw I: ~ ~ ~ ~Xm z S l-Q.. U1UJ ~~ NV1d 33S C;31~V^ '13 .~ gl~V^ .13 z ~:5 U')a.. OLLJ -, L1J (/) -1Q! ~~ ~ ~~ r:D z o t- u UJ 01 P.03/05 -J ~ L&J~ J:~ I: Q ~ .f= ~ :: ~ ~ ~ ~ o ...J ;! L1.I I: ;c... ~~ ;t ..z ~L -~r ~ '"... u -. XfJ') .~ ",... .....J ~ @ . -2000 17: 48 DOUGLAS R, IVERSONt P~A. 6550 YORK ftr,vE,. sa., EOIN~, MN 55435 (612) 920-2330 FAX (6'2) 920-4493 FAX Date: October 2~ 2000 To; Tom Sand (651) 9OS-3678 (612) 920-449] From: Doug Iverson RE: WARBHOUS~SHOWROOM WENSMANN HOMES PRIOR LAKE. MINNESOTA Memo: Enclosed is sketch SKOO930s showing showing an extension of the bearing plate and a.nd weld for the three joists in your fax today. I have U$umed that the joist relationship 10 the plate is as shown resulting in only 1.... of bearing, If the chlMel that I have shown cannot be installed as shown, please advise. If the reason for only 1" of bearing is because the plate has been set (00 far back: from the wall edge, we may have to extend the bearing plate forward instead. Please call if you have any questions, P.04/05 @ -2000 17: 49 P.05/05 DOUGLAS R. IVERSON, P.A. Structural Engineers 6550 York Avenue SQuth EDINA. MINNESOTA 55435 (612) 920-2330 Fa. (&12) 920-4493 JOB~~.~l P'lI.4..l~~ ~e... SHEET NO.5 ~ 0 aQ 2a~ -S OF CALcuuaTE08Y~~\ DATE~~/:l.Lao CHECICE!t1I1 DATE SCAI.E--B"......I~.. t;.,...TR.... ~..a~ ._~~. ~V\-.. , , ' .' . 3 . , ., E:~.\~\.~~ .(b~ t2 ~,\T'~ S'nJOr PileI o. C 8" \\..5 " \~- -ro L~TLUO ~t~I~" L~~c.~ .~) sie".~'" ~\~ S~'-~S (;Mea DC&..O At t'-" 'Nl \.AU""'^- ~.. 4. , ~'10 ~ "" c. (l. t TW- Q;.awO t8L."-^. ~''IIM.I~ p.Iol..""..... TOTAL P.05 ~ - . ~.-^~ - -' 'l W6M~~ fila ~ ~ ~L. SrAla.., 'Do ~ ~ to \!e-- ~. \. O~ tPr \\ \.:> 2. ~J C-ffAlf Ljpc: ~ Nd ~ 4 \ uJ(P&= "2-84 io ~ ez...v..V/h~ ~k / 3>f/, 0 +os- ~t7 (9t:-G ~ ~ -=- ( e>G{:. ( <obo - \, ~~ :; . f · 2-~' ~ ---.. \(,1 Q ~ \ \ Co ~,o c &1 CJe/0 ND ~. 09[20/2000 14:56 6517489143 FIRE-GUARD SPRINKLER PAGE 01 FAX TRANSMITIAL Fire-Guard Sprinkler Service, Inc.. 1055 White Bear Avenue North, Suite C st. PaW, MN 55109 om~c; 651-748-9499 ,.x: 651-748-9143 MN LicenM No. COOO18 WI LkeDIe No.. sc00001J9 DA TE:9/20/2000 FAX NUMBER:952447-424S o FOR YOUR INFORMA nON FIRM:Citv of Prior Lake A TfENTION:Paul BaumE.!artner o FOR BID DUE DATE FROM:Jason R. Erickson NUMBER OF P AGES:5 (INCLUDING TRANSMITI AI... SHEEn RE:Fountain Hills/Showroom 4385 Fountain Hills Drive MESSAGE: Paul. Here is the sheets Tom Sand sent me on the storav.e racks. Thanks. ~ SIGNED 09/20/2000 14:56 6517489143 FIRE-GUARD SPRINKLER PAGE 82 1895 Plaza Drive Suit. 220 EBgan. MN 55122 151.406-4400 &51.90'..3678 Fu Paul Baumgartnec RE: 4385 Fountain Hills Dr. Prior Lake" MN 55372 _............~- .1)car Pall!, ." ..--." --.. ... -..- .~._..'.-. ..-........--..... . . 'Per phone conversation with Jason at Fire-Guard Sprinkler, Jason stated you need some information pertaining to storage and storage racks. Enclosed you will find a diagram for carpet racks for warehouses #141 &. #127 with locations to where they will be placed. From my understanding" storage racks can not exceed more: than 12'.0" in height. (which they will indicate.) F or warehouses # 117 & #107, tenants have not been fma1ized at this time. I will make sure: that they will not exceed over 12' -0". I hope this information is helpful for you. If you have 'any questions, or concerns, please do not hesitate to call me at 6S1-40~-4400. SincerelY7 ~m., -L.f2 Tom Sand V .P, Construction & Dc:velopment 11 09/20/2000 14:56 6517489143 -.-- ---- ..- ~ .:.; '" PO.I-I" Fe NOle 1811 01.. To 'fDfft Ca, Pl\Me . PMne . fu.. h. FIRE-GUARD SPRINKLER l . d Z 6.t 0 YW I ('\I"" In.' I '''''\1'' ,'" I.,,,,... .". II,. ,. , PAGE 03 I~: . t") ctl' s:' -E '. & ~tV' cs" "'~ ox "'c "".. ; ~. ~~ 'U ..~ ~lf) ~. ';) fa ~. In ~ ~ .,- M'liD ",,- ~ '~""J - .~ ~.g, ~ O. C.o::: ~ . 'v) t-' (:) .~ Z .~- ~c5 ~. z ti~ --' . <t ~, ~. W. 1--. <( ~. 09/20/2000 14:56 6517489143 FIRE-GUARD SPRINKLER PAGE 04 re~, I I, lUUU II :1/AM MAltKIAL HANDlING/NORSTAR ND,3492 p, 3 :.;,;, ..,..~-fII"':!.~ . . . .:I!...:~.,: . ~..wo-"'~ _I&-., .....~. \ . " . ".~~,,, ' ~N'1 t::Lev"'LvN f';:f!l" ''r'' - .,~ ,..--. . ,:;':~-: . :,~~-.~ .,j . ... ; I ...., ' ,.. ""I"~ ," .,J .. '~"'. . '/ ,,'!/J ....' : /..,..:. '. .~ .' rtl, I , ...' ,.. \ t: .~ O.F " \ . II' Ii /!;'. O' ""\"''','j.~! f';'~\ "!.:~.' ,,' 'I .. .,,~?J I l~. y..! : ~ ~ . I() ,; . ':} \,' '\""Tb? " ,", ~N ~ o~ ~t-!. \. . "; "~~~,. :'::,~ ~.,...~ -::.~..- ',. -:,' . ~"."....., -~.~. .~ ...~,..--: _., ... '._ ..:,...1.:....... ....'....:. .,.:-:~ ...:~.......... ..,.. e ,. ~ - .. ~.:-: '\" .oj_.r'~. _. " , ,", I. $-- , I, ~I~ \ll~ O~ ':8.~~ ~^~1'"' ~t)f ~efdf' ,,~.,.~ ~ Of ...~...'......... "'0 1";1' (" " woet> ~ '--bo~ W~.t{~~ ,t~.,t-l) '. " ., \. ". , " " II '2 "'ZH ~aet) I ~~(~ ~ O~ ~M .. \ 0 ~~,- ~OL/... S~. W9"TA-LL a~.r 1~~''1)~ ~ ~-p \+---L.D~" '":~c.~ )(-t~",'t. N'-\..M.~ 0 F- '8tr~ *~ . <9 LJI.'i I"JC"~~t 90' ~-rop of a")I~" "TD"r/:'t. \)~ 114 ~F N-c"- · (!) ^ I r1\et4 \JJl"'\H ~ H~D -;~Ji!elJS CD /1 \ 09/20/2000 14:56 6517489143 Lt- -.- ,1lI..- _- DII'lce . Iz UI~REHOLlSE .... N ~1 ~, "" N ~-- l .' ~. . . "eRE t\ TIVE ',-DORINr.- :, -.. '.., . "; FIRE-GUARD SPRINKLER , .-- .....-............".. .~...-..... .,,..-. : SHOIUJeOOI'1 ,. ...... ----I , , . . , I . , , . [_.... ...,~"::~=r' po- ----, , . : : . , I . : 1_____..-- --~ CONF. PAGE 05 CON', \"z t ~'J,p .:~... >'.':.::" -" . .. .... . ~"'. .::1 . "0,.. '- .. .CREI\ TlvE fLOORINO. FAXED :., FE 8 O. ~ J95S G . .. .' ,. - .. . - , I . , ~.... . -11 DO P.01/03 OCT-20-2000 16:15 c......._dtil.a1 r ~ ._.. c..a 1 r ~. . "" _......... MIa 2:ID . ......... 8m .,. t* ......... .. "FAX COVER PAGE DATE: TO: FR.OM: 0l1-.. ~O . ? nee ~\.4..\..~\~( · T()~ Se..O J 1.1 ..,'. . FAX.: NUMBEIl OF PAGES INCLtJDINGllBS COVER. ~1'jmt: 3 ",. SUBJECT: ~~, ..... ~ ~~~ ~(1'~ IF THIS PAX TRANSMIn"AL IS NOT COfAPLE1"E. PLEASE CALL OUR. OFFICE AT 651-406-4400. 1HANK YOU!!! I_~ f) ~t. ~.. ~~ OCT-20-2000 16:15 ~, Insulation Specifications 1,~ GENERAL , ,01 RElATED WQfllK ~er Ia memb/InC lIIIllUJac:l1ll'tf'S _CiIliIrI guIGe. , ,02 SUBMITTALS A. Wllnit AMi, ~ cilia. a gfllTlpl,,~ " ~ lIlGIt N!I8Il ~ .. _IGlble AIlII F )If llllU~1lft IpIlifJCalioft. 2. Sublll\! Dn8 umplll, ." 1l11', rJf rDOr inllll. liol'l malClla/. c. p;ovidl II ""ill 213-[11' Umir." WlrflnlJ III ()war 1/'lennII Wlllue gl r~Faarn-f1J IACF~1111 [Ae' ClIIn SlJpnmel [~1Ift Con.-it.) [T~ .cF......l [ACFDIfft NIl. But Ift8UllaiclnllVl!I'WlId-R) [.a OM! Rc=vcr Beard), 1.~ REFeAENCes .. ~ Sllciely fer't'MUIg end N,lIria 1, D 312 Spccilicalilft ''ill'' JIph. U'IIIIII in RDaljr ~. B.. FBdIral5ClldfilUfn (F$). 1. FS (GSA) ~1.1mJGBlllHt+4."72II1 ~ I~- 1872/1) (t1t1+1I7ar.IJ F_ POI~K1I"' "It Thermlllll'llula6an "rd. 1;:, F.-IV M~ S~ "5GfM1g ,. Qaa 1 ,11: IIIing.. 2. Windlian1l ClMlifa1kan (1-60) (1oecIl c, AlII!! JIlIlaI 1ll!~1fcII ca_ , ,04 DEUYEA.,. STDAAQE AND HANOUNG A. IfllVlllIon,......... be '-led 10 i1clucl. f \alt. IbI "UI'Ie. ~ 'JMie IIlCI praduft eD4e. e. WhM s_(II DUIdoDrs. irlsul;t&ln IhiII tllIlIadl& a CIfI JllllleII r:Jf~. II leu I a b:Mi IbM glllUllCllIMII ns ~rad WIIh ...,..,.. r1t DJW $Ui'liiltlIG ... '_ ~ 181'" nmMd by 1Ii,*," III' m Df 1M (xlary _led ,....,. , .CIS PAO,JECT CONDmoNS A. Fan. a.caJ, stAle m'IIl r..t.ta! regul.~D/lIi. Ilhlly "w.. _.... WNrt . alI'I/lld alsts. !doe ltIe ~r~ 6. Faa. illc&l/WlCa IlNierwriler'~ ..~ .1:_ UIe for lilt _. pI'Iduct$, ; ..;.....:- . I I , ____.B sprl .@ C, Od nar W1Y1l'IY "*'"D 1I*!tIa- ""etI WI. in :a" fo"" i, pruenr or prop'r .dhe.~. IlI1Iplralure un/lOl. mlinllirlld. g, The ,., 11"* stili ... dlY ItId ~. -..1lIl Ul IlJPJOY{ 'hi Ii.. and lI..d Idd rcquirclftcnls "t raolllla ~ arlS IlIlfGenDv rigid ID auppQIr CZlft- I1Ndian IfIII'IC I 2.0 PRODUCTS 2,01 ACCEPT~DL.E ~NUFAOTUAeFl$ ,., (,lCFum.O) (ACFGaI'JoIIIJ [ACFClm Sll~rtmel IACFolm CGlnIlDJilllJ [TlIpIl'ld ACFOiIft) [ACFoam Mia.. Inmarl8l11 [VCtltcd-AlIACFOIm R,.., Board! II InIIlUfIcSa.ftd br-. 2.02 MATE~IAoLS Ar AWlnsullllon. 1. RDId Inlul,li'n: t~CFDam.lIll"eFo&m.III) [ACFoillft Su,remel .IACFllm Camp"'le) [Tapmtd AOFoem] (ACFaI&rn NIiI e.. Inslll- lion) [V~ [~ AlCiWtr IIaIIdI ,., """ rl1lan lMPIufaaunwt MU'\OUIII'III UlI DI ~ntan. Dr CfC,.11 in ~ wIII'IlN MatllrM ~ " IltImplyfng willt Fede,., speQr~rio" (GSA) (MHo-I. 117M11!N1 [HH+"nIZ] 1"1-I-1-1972f1] [,......1. 197"l13]. ti3vlng I a:nJHned ...lmII...... 'R' ""UI of _ ."., CC1nd\i,"" uCQrding \0 PNA .,. No.. to'l _ AICItlJ..lIkllllllin N", .1.1, B. Rtlaltd Maleri" 1 I ~fICIed Membrant 2. ADDI ~ ratsnlfllWfll'Jed bt~. 3. B.1II! ply II ~ tit I1ltft1tnne mlltWr.c- IUIIr. 4. AspPIllllilUnlell ~ ~ _Ill ASTM D 312, ,,1Id ... 11M In M of... F. &0 EXEC:l,ITION 3,D1 PAEPARAT10N A. '''are,..1 "'-'..on ._liall il IIItIId. rtmDIrt IIMtI. dIbris, 8.... d__t, llIaIIure WId ~~ ,., ..hid! may alrl!lllhl! .-c:trnIN 01 '" iBMIian 10 \hi'" ~ ~ ~ ~~~ 4ffil' . ~'.',...:"; . ...:..,.;;~.t ..'.. , for More.lnfoRnatiDn .0.-.:.'.. 011,. '..' Tapered l...l1Iation Department - EIII (800) 933-1476 · F~: (770) 955-41207 Tapet8d Insulllian Depl~nt. We$J (BOO) 646-1476- FAX: (30!) S.7&41 I -1--' t 1Ii~ (aDO) 677.1476 · F~ (309) 752-7127 N~ (BOO) 688-1476. FAX': (717) !J75..6957 Marth". (800) 281-1476 'F~ (303) 252.7641 Sautll cetllrll (ICIO) 766-147& · FAX: (-i09) 829-i363 Saultleul (800) sss.147& · F~ (706) 882....047 South..., (800) 477.1'76 · FAX: (802) 833-~ P.02/03 B, TM deck IIhIllI MIUlrlCi_ rigid ta cUOCMIf\ ttle roo.. InG mld'lrlniQ!lIIlliptnl11l .-.0'" dIllldan thai .-II still" (lr' tdplute any .1 1M reolIno ~ nenat ar dlfarrn aNI ~ C. ~ d'P"IIiIlltI. fteI~, defatJMllans, el.c., ~I bl I'fIllfe Jft\CIIIIlh pNt ~ Ihe lUf iwI'-ilOlft IIfIpliGalial\. D. T,.aIIMI__ iNullliClrl ..,lI\c ,..... ~ as 1M lMu\il5aft, IhIII f11111111h1n_ "1'* allha .delS 01 h dtell."., ~l'&IIIld 'II ptoleellolls ~I\d optJW\gS Ihtwah ltIR deck. 3.02 AP"UCATlONIINST4lL'. T10N A. ",..1IoM AppIv I~FcalfMq ~Ft.m-llg (ACFaem SUpr.",l] lACF*' CcIInpI$II [TlpII1d ACfailn'lJ [ACFoIrrl ~ Buo InaulalloN [Venled-AIIACF~ ....... IaItd) 1Nu1,~DI'l in 1CIlGl.... .iIh All. rDIIf rwull&ian r.-Iog ItId u fIqUiIBd by _. and il\Sl.IFanllllo n. rtquj,.",.nllDt I "'0' relard.r ~ be dllem1~ by .. M:h/I!cl*""Oll!ftGlMer with 'np.ll plWidld by !he ..ilding ....r ft lIIlCDr- dlllCl with WNI'II ........rina IDmMltIs iVl' vlpGr 1t1.."lNhen I YlIPD" ,.1a_1e ."ed, IaIIc1w VIpO' tIlIad.r mlIIIlAII~l. .-.mInIInraIiaI'Is. 3,03 CLEANING A. Rem..,... nth " MriI r",", reor iMublOl SlIt. _ prior ID lhll.,ar:atlDll of ltle I1IQ"M rnembrlnll. 3,04 PROT&CTION "" I,.stalled INIlII~Df1 sh.JII nCI tit left .-pallid 10 !he "''''Ir. Illhllllle c;gw".CS .nd walarpfCIGfId ill onCll. 8. AI.....-d edgIIleft . fie _ at .. rJayr. WIlIfl51Ta1 be ~ ..-:l by liIIDCla fIIIlIlrIt lft.mbr;n. .,aIM......., 1IelrlUlIm'IIIlf _tIQ _In plact, AemOVI ~hi. m.lI1brlM 1,.1 -h," WD~ ...,11I-. rr.stIIIed irI~ Wh~ ". becDm. ~ IItdJor dIIm9d !ll\ll1Ie IIfNM!CS II1d ,.- . dd IIld dry IIlIIIwiaIc. c. PrCllKl inaiIIIIcI nutaliOn "'"' lI'IrlftNe rrolll tOOl 1rI111c__"...bru*tg..... ~ 1IUdl. ~ if! .... ..... -.y ."." ,.,.Md _c.3Mdpi8G IIlUl ""' 1I1d. nsaIa&Ian. ,,; AIIIut~ . .,'. :' . As we enter ~99'..1hl yelr of .... Oly,"pl;1 In ... _ . ~ ... ~ 01 (IIJf c::DftIIt1Itn'I and 1IIPia!IIIsa.1ft ~ .... ~ iUIIon praductr.forthe amStI'uclion and IetNrtl al nny .....~..., 'ri". QnI Ill... ~~s ICIng DarN.1Iame at ........,. ~ O~CIIISlNdId in the 1~.~.tcnJ.~ ~ ..._,. or ,.IrOfttJf1~.~ '~:gat under "1110 ~~~~ ...,..,..car- POrf!i;, ''',;t,r,g~' I 7..~.P.:#Ir.e,~' oj 1-11- ACfoaiII~.-. .:'?IJ;~ ~ Ind ~.... 'o~~..-en Ile.Plit~.~. "! ,.... . ~~~ ~.~. .'. :'~'-"Dn- :~"i .. .'. " . ~'iRsidr!. ..- .'.:" s,~'~ :. ".1. '. .. .' 1.1...... ': w., ,_, l Atlas Roofing Corporation , ns The ~changet Suite 160 Atlanta. GAOrgia 30939 _llJIoJ!.- u. UA." It.U...........,....., ~ __O~T-20-2000 16:16 P.03/03 D722D1A TL Buy6ne 2130 -;.'"" ACFoam--n features the Atlas dC5ed-c;e1l pclyiso core integrally laminated to heavy, b)8~k (non-asphaltic). fiber reinfarced felt . f~cers. ACFoam-D has a perfonded facer on on8 side for use wnh hot appUed $YSlems and a non~perforated side for single ply systems, making this a universally adaptable product, suitable for a \lariety of applications. ACFoam-U is also avaalable in 2S psI formula. ACFoam-U is sp8Q'fieally rlcommended for hot asphalt or coallar BUR, modified biNmen .nd singl.ply membrane systems, (See BUR, Modified Situmen. and Single. Ply Systems pages 7. 8 and 9.) CClfllp/i*lM:D: - Fedef'll 5pecifinUon ""+'9721GiN Ind HH-I-'Im CIa!! 1. . AS1'M C:12&95. fjplll. , MlIln1-D1fe CUllY. f11Dlidl1 P11Idud. COl'iIllll.... DOIIlL7. . Cllno",", S~t. IrlSulallDrl ~_ scanOudr Md Tille if FCJlM F1elftCl\sbifty Crilaria (UalrlM ITC: 1231). · soeA, ICBO, ar4 SBCCl58cIianC 01'1 F., Ins&AIIIGn. . CCMC Na. \a4&4.L . Mcf!lI CANIOGSB SIandMII, ,- -'-FM st.JnrAMI~ ~~ ACFoIm-II iIi ~ lor CII,,' 1n."UIMId -. WId . aan Q'W1a ~d gypMIIft ,_ cIedc c:arlIiln.IrlUn .... 8DIt, I-eO and I-Il Windtlorrn a.miftcaliona (may be "'DppM ar ""IlI'!."rc.,t Itsll!ned fll a:lNnle root iIc:I&), Acrer " JIM ~ GuidI hI!' _its on ~ __m, UL SI:andn '251 CSa!l~IIIUQon: Il1Iulaltcl m.1JI ~flCk eo""NCdan ~ - Cantlru. Il2D IIId r123. lJL 5bMud I. c:Ia*i.-lian; CIa" A WlrIUI "'o.t& ,,,,, III~ IJS*M. See UL Il6ffn I M,.~ D"~. UlSlllnllar1l 2&1 F'", Reridin. ca.r'11allDn (AmI 1'111) Some dasslllClllans '''' rn ~ ill PZ!I.. !t2:XI, 11I2$, P2S9. P2&3. psae. P510, PS1.. P7a,. P110. P7l3. P71i, P'7111l, Prig, P72a. Pla P723. f'724. P7U, P727. P72i. P7U, P730, P13Z, Pla1, P81., ".15, P117. Pll., P"~, p~ 1nd P82A. $.. Ul. FIre RdIMce DnnIrv ror U~'l:I' ~. UL ,,' CWIIlRi: Insulal.d Flaa' Qec:k ~!1elllbli" . CO"llruc:tio" 'eSt.. w_ CANNt.c.S12&M08. ACFoaM'-1D also featuf'lS the dased-cell polyilo foam cora integrally laminated to heavy, coated glass fa08ts, ACFoam-nl. which fea1ures a taugher fac;er and is more dimensiona11y stable. is speciflCllly designed for aU single-ply. cold a~pliQd BUR and cold applied modified bitumen membrane sys. terns. (See pages 8 and 9.) DO NOT USE WITH HOT APPL/BJ MEMBRANES, I.f. COAL TAR OR ASPHALt ACFoam.m is alSo available in 25 psi formula.. C8mp~ . FederII SplAratlalt HH-I'1m12, 01....1 · AITM C121f-15, 'f~ II. · ce~ ,24zs.l FM s-... 4Ii8IM7I Apprri ACFII!III\oDI if ~ lot au. , irllulllld -. 'ftlId , __ ala IIMI gypswllDGl deck aan&It\.IallClfllGr bolh J.eD IUld I.to Windllarm CllSItftl:lllGftL A.,., ID AI ~ppraval Gu1cll! far de"'. on...Iie.... .cFclam.m IS IDIIftd bf - Dr IlIllI'I ~ tl 'a1efl\ IS.DII1.*- ACFoam* Aecover Board is pan of 'he Atlas family of thermslly efficient polyi$o foam board insulations. The foam core of Recover Baard is CIus 1 fire rated whic:h is covered on bQth sides With . heavy, strong, coate" fibrous facer. ACFoam Reoover Baard is speCifically designed fer use with loose-laid ballasted and med'tanicalty attached singllJ-pIy systems as well as cold applied modifiad bitumen and cold appfied BUR system6. Its primary fune- tion is to provide 8" improved substrate for the reating membrane in r.cover applica- tions. Check with the membrane manufac.- turer regarding approval$ of this procfuc('lS a membrane substrate. DO NOT USE RECOVER BOARD FDR J:lOT APPLIED ROOFING SYSTEMS. ,...,1IGInl ~ ecwr.tIIII.,.. II' 11Ift .... "''''I5.C1,DJ1, ~WR 1\" a.1in~ CGrparDt.IO.. ~ 10 JllIa.!JGlUs.avew. UI1ID BY: _a........... D.n1 r... ill SouCIIM ........ "".. "................,.... IaItlWk o..IW ~..... rut.....m Sa"~ TOIlS ~ ..........-c... ND.QA_ T..... pc; AlN E ... 11 IIliIMaIe "'1- r..","" WI.. 'YS or lea s..... Dtv...... bOG 451..... · (1'11I4IIII ~... ,....lI'l """'" & ~fIjG CCIAPCIlATlON 3 TOTAL P,03 -~ -~'-"""-'_.-..-........--.____...._._~ _ _.._<.J->.,-_,...~~,_.~. ... _ ............ .._ - _ <.,...... ____J :;- 0 0 0 0 ~ClClClCl "V 0 :.- -0 rn 0 X ~ 0 z_ -0 0 0 ~ "'TI-"'TI"'TI"'TI 0 C ~~ C1l 0 0 3: --Z~OO z a 0 9- ~zen c:o z m :::u mo :.- 0 :::a :::a :::a 3: ~;a.C:i:Z~ m :::u m O"'TI ~ :1 :::a :::a ,.. en ~ r- m m m zr->zcz Z en ::I "V r- 0 0 en Z ~ ::!Ci)~Ci) P O:::u ~ t ~ ~ ;a. z- ~ ;a. ~ -t m 0 - zO tC ~ en en o Z 0 ch 0 ~ z o:::u S ~ -n C>> :::a 0 ;a. 0 ::I~ ~ 01 r 0 0 Z ~ Z 0,.. "TI 0 ;a. 0 mm ~ 0 ;a. Z ~ :::u r- c r- ~ -t ." " " . ::J: 0 :::a :::a ~ m :::a 0 0 000000 z :::a 0 0 ~ m m m m i:"'Vcn;ei:"'V >< z m m mr-m>>mr- -t c c oC:~~oc: ~ Z ~ en xi: mxi: 0 en I d "'V "'V en m "'TI!!!:::a:::a:::a!!! m 0 0 c:l ~ " ::J 0 zZ:a::a:-z ::u Z x C1l ::! m ~ ~ ;a.Ci)OO Ci) i: ~ m rg 0 5 r-"'TIOO :::a =t ;u 0 ~ 0 z -,..,.. - Z c: 0 3- zc:c: r- ~ ID ~"" P ~ m z :1 m C -n ~ N 0 " ". C ::J: :::a m ~ 0 0 c: 0 & ~~ :::u < 000000 en m ~ ~ ~ ~ z :::a Ci)"'TI"'TIom :.- Z ;a.~~0~ R- C Ci) ~mmi:Ci) ~ ~ ~ _"'V""'V~ ~>>>c C ~ z ;a.ooz:;; 0 ~ ~ "'i !11 _mm~_ ... ~ :::a"'TI:::a r- ..... i ~-_ r- , enZ z m ~~ Ci) <l\ A ~ :;- 0 0 0 0 D~O 0 0 0 "V 0 :.- -0 z_ rn 0 ::J: ~ C ~~ -0 0 0 ~ en"'TIz"'TI-n-n 0 C a C1l 0 0 3: =izen~OO z z ::u 0 Sl m mO :.- g :::a :::a :::a :s: ~;a.C:i:!E~ m :::u m 0"'TI ~ r- ::0 ::0 ,.. zr->zcz Z en ::I" m m m en r- 0 0 en ~ ::!Ci)~Ci) 9 O:::u ~ t ~ ~ ;a. Z z- ~ -t m 0 - zO ~ ..... ~ > en en o Z 0 S cO 0 ~ ~ Z 0::U C>> ::0 ~ 5 ::I> ::ll:i 0'1 r 5 0 Z o~ ~ 0 Z ~ "TI 0 > 0 mm ~ 0 > Z :::a I". ::u r- c .-< ~}- ~ -t r- ~ -n "'V "'V . ::J: 0 :::a :::a ~ m :::a 0 0 000000 V\ z ::u 0 0 ~ ~ m m m m 3:"en;e3:" >< z m m mr-m>,mr- -t c c oC:~~oc: ~ Z 0 en :a:3: m:a:3: " 0 ~ en ;t " ~ ~ ~ en ~ m "'TI!!!:::a:::a:::a!!! m 0 0 ~ "V ::J 0 \I) zZxx-z :::u z t ::J: ::! m C1l ~ "1 >Ci)00 Ci) 3: -t m 0 ::t 0 () r-"'TIOO ::u =t ;U c rg (") ~ 0 Z -,..,.. - c: 0 3- zc:c: z :$1 r- ~ ID ~"" 9 m z :1 m C ~ -n ....... N 0 ~ ". ~ X ::u () m ~ 0 0 ~ G ~~ c: 0 :::u en < 000000 ~ ~~ m ~~ ~ z :::a Ci)-n-nom (i' :.- z >~~O~ R- Ci) .~mm3:Ci) ~ m ~ C -"""~ ~ ~ ~ ~>>>c z ;a.ooz:;; "'i 0 _mm~_ ..... --tl !11 ~ :::a-n::u r- ~, ... ~ ~-_ r- . . i enZ z & m ~~ Ci) ~ ..... @-. @-- -@-- I @- I~ m . - ! --+. 3 =;.7: ~ .~rh""'" ~ ~Irn ~ 11 ~ ~ _ -^ "lffil... ---- . . " "',,! ~ . ".LL r----....j at 1...............1 o o I o ~ '" R~ =~ I 7 I I I I I I I I I (: 1: 10 10 Ill! 13 10 II Ill) I I I I I I I I I .::> I ~"II '-- ~ ill il ~ IL b IL ~V\ .. o f? o ~ '" ~----------- 1 i L___._.....____ ~ ,.'"," ~ ill lI) ::l o I ill lI! 4: 3 .\ , , \~... - Ii \~ ...; ..... I ~ttttI IVI L r--I I~ ~ t:~ 1: o o lI! 3 o I lI) "", .g-.~ II . -,' ... ~~~ l!~ ~~I!I" ~ I', I,' I,' I~ 9---~'-- -. @ /\.,.,.... I I ~ ..-.. fJ ,0-," ). I~ j :5 ti . .., ~!~ . '-F-) ~ , -,", ~ L"": 1: o ~ r------'h 3 .. ~ L_______l ~ lI) i I~ L.: I "-, I~ 1: 0 0 l:~ lI! \; 3 ~ 0 I lI) G---'-.---.-.-------~. --=r-' ~ "Ll ,,0 -,Zl "u- ,9~ "U,9~' "U,9~ L~:::::::: I ~~~)---, U!\r;-1 '> ~ s=:a m o ~ -- _._._._@ ill ...J ~l ill II<' > 0 ~ l- ll) \:J ill Z :::lii z Z wet:; i= 4: ~I U:x: I N E~ \:J N O~ ::::i ill 1: --_._--@ I I l.I. U o o ill lI) ::l o I ill II<' 4: 3 .. ~ ~J ./\ ~ ~ I 1 I ~ ! _________J f? o ~ ~ '" - ..-t< ,'-~' 1 ,D-." ,O-,U' ~ ~1 ..... I ,.,U' :l u . ~ ~~ ~ ~. u: : u: .~L~~ ...., r' r .......- .'-. .0'-.. , ^-..i r ;, -' ~ i! _kSi ~ J ~ :' l.I. ~ .. ~ .__ __ ,0....,.,; ~ t{~" '/" ~ ~ ~ :ll~ r rLL' v ,0<<' ill U iL LL o ~ I ,,0' ,vZ ,,0 ,l<; "U ,9l ~ ~ T i ~ .. ~ ~ ~~ :z <VI .- - -~. "O,ZZ ,,0 ,lZl ~~~ ;::= d-d-g- d- d- ~~~ 1Il 1Il to r--.. ~~CX) C"oJ I"'"') ~S?C"OJ I.l) C"oJ I"'"') ~ I"'"') ~~~~ d-d-o-d- en en en en L()-.;j-Or--- L()-.;j--.;j-co CO 0 -.;j- ~ Vi o Cl) ~ :z o ~ <( ---1 ~ m <( ~ <( w n::: <( c o E E W 0 ;:5 a5 .. UJ en U n:::<((f) ~~2 <(~~ 000 W w n::: en >-. n::: I- ~(f)n:::<(~en.D..c 86n::::zg~-g~ ~C5~~Cl35:-.-J~ ~~-g~ (f):!=C"oJU ("i") - c....:> u.J Q l.I. U o o .. ~ ~ ~ ~I o I___________J !1 o ~ .. ill lI) ::l o I ill lI! 4: 3 ,,0',8v l.I. U o o o -0 I- '0 C o (s @ 'c I '~ ill lI! o l- ll) ~ E ~~ \:J O~ ~ u;1 ~ ~ I <: o;~ \:J~ ::::i <: @ C I i; " ill lI! o :n 8 lI) ~ ill ~ U 0 ~ "I ~ ...J VJ :x: lL <: Vl ~~ @ 'c I S u:: \:J z Gi o g LL ill > i= 4: ill lI! ~ (, z Gi o g LL 'c I ~ UJ ~~ > 8~ ~ ~II~ ~~ G N 2 <( @ Oi 1: 0 0) 0 0) O! m 3 ~ Z 0 6~ <( I tI) ~ p -l '" < ~ (L W 0 tI) () =:J 0 Z I b w I 0 O! ba: <( C'oIUJ ..J 3 II a.. ':J ~~ dl w z w ...J ~ < < .J ~ ~ >- j:: 0 0 ....CD ......... ~~ 0, ....on ~i (D_ on ~~ O~ x-< ....u.. .... ii .... w' >.... a:~ o~ -<z ~~ iz :;:~ CD-< _w g::]~l ;~:~~ :SoEE~ a.......::J ~~f=u i; :~~ eOE..< ilrn i ~ l ~.~ _ .. i5...a: .. a: .., -~ ~ III 0 ~~ ~ >- ~ ~ ~ g i i ~ ~ w>-<i lIE Z .a ~ ~ ~ ~ a ;; al al ~ i ~_g- ~ (:) g-~ ~ ~~ 8 ~ P.01/03 .~000 15: 06 1895 Piau Orive suite 220 Eigan. MN 55122 651.40&-&.00 551.905-3618 Fa.1; "FAX COVER PAGE TO: FROM: FAX": ~ c..t ,2.000 ~O'a lt~+t."',~~- lo~ ~od. tt~2'~ ~41- '4GLI~ . DATE: NUMBER. OF PAGES INCLUDING nus COVER. LE1TElt: .3 SUBJECT: ~\~cz.\"* \)J~\d. ~~~ 1I-~O{-l-. ~ ~eMlVks I IP ~OLt f14:.'\ '-"fy ",LI2R p~tJ1 fr~ Dow; :r;-M~tJA , _~+ t')\tl Krnw ~ -:I: L~U FPr~ -+0 "Ou .. A\~Q 5\1lD..L\t\ hP..", (et.\e.~ct y;>~.f ~~\ I ~ -+ -MA.-;'~tW'f f2epcA... ~-+. 40. ~~. .rv1eber~ ~M.- IF nus fAX TRANSMllTAL IS NOT COtdPLETE. PLEASE CALL OUR. OffiCE AT 651-406-4400. mANK YOU!II .~000 15: 06 P.02/03 STCR~~ Twin City Testing Corporation 882 Cromwell Avenue, 51. Paul, MN 55114.1n6 (55'> 64S.3601, Fax: (651) 659-7348 TO: PROJECT: Mr. Tom Sand Wensco Inc. RHS Building 1895 Plaza Drive - Suite 220 Eagan. MN 55122 FOUNTAIN HILLS SHOWROOM WAREHOUSE PRIOR LAKE. MINNESOTA DATE: November 30. 2000 PROJECT NO: 030238 VISUAL OBSERVATION OF STRUCTURAL WELDS GENERAL INFORMATION: Date of Observation - September 21. 2000 Visual observation of structural welds to determine if they." meet the quality' and workmanship requirements of Table 6.1 of Section 01.1-00 of the AWS Structural Welding Code. Scope of Inspection - Observation Personnel - Ronald Wappel, SNT-TC-1A. Level III Technician Location of Observation .. Project Site TEST RESULTS: Visual observation was performed on' the fillet welds joining the bar joists to the wall plates. The following are the results of our observations. Line uA" mezzanine to wall plate welds on joists #3,4 & 5 are approximately one inch long rather than two inches as indicated on the drawing. The welds extend the full length of the bearing surface between the joist and wall plate and are acceptable in quality. but are too short because the bearing surface is too short for a twcrinch weld. Infom'lalion iIIld 8taI1ImenIB in d1is r-pgrt .,. derivlld fRlm material. k'tla~ tlndl'0I' ~one IUmllMd bv fh_ cl\enl 8r'ld elI1:lude any 8ICpr...-d or I"'plled wlr_lli.. 's 10 Ih. ijlneu of !he rnal-ritlll..tecl Of .".,~ fclf any parlJctMar purpoN Of UIe. ThIs rJlPDltIl the COI'l'~ property of our I;llent and may nat be UHd 10r ~ti$ing J1urpoael. TtII8 report shaU no\ be repltlduced lIIlC8pt In lull, WIlhouI written ~ of thI5 IlIboratary. The recording cI "IN. fIctlIloue of Ir..udlJl8nt stalemenlS 01' ll(1\flea on this daun~1 may be punistlecl 88 . leIar'ty under Fedet8I ~ including FedOral t..nv TIIte 18, ~ptIilr 41 .4d000 15: 06 P.03/03 PROJECT NO: 030238 DATE: PAGE: November 30, 2000 Two VISUAL OBSERVATION OF STRUCTURAL WELDS TEST RESULTS: Line "e" south end roof joist to wall plate welds are not as indicated on the drawing because the pockets in the wall blocks had to be extended to accept the roof joist and the plates were not extended. The center of the joists are bearing on the wall plate, but the fillet weld joining the joists to the plates could only be made on one side of the joists. Short fillet welds were used to join the other side of the joists to the wall plates on the front and backsides of the bearing surface. The welds made on the side that could be welded are more than double the length required by the drawing and are good quality welds. Lines "B" and MD" southwest end, wall pockets and wall plates have been extended to support roof joists. The welds joining the joists to the wall plates at these locations are In accordance with the drawing. All other welds inspected are acceptable. This includes all joist to beam welds, mansard roof beam to wall plate welds. deck to joist welds, and joist to wan plate welds other than those noted above. Approximately fifteen percent of the bolting on site was inspected and found to be acceptable. REMARKS: On September 22.2000, we recommended that the welds with inadequate length documented above be reported to the structural engineer and repaired in order to meet the requirements of the project specifications. It is our understanding the structural engineer was notified and Instituted corrective measures to the welds in question. We were informed through our phone conversations with you that the corrections were inspected by the bUilding official of Prior Lake...., and approved. We were also informed interior finishing has covered up the areas in question. If you have further questions please feel free to call Mark Straight at 651-659-7447. Thank you for the opportunity to perform services for you. STORK TWIN CITY TESTING CORPORA liON b.~<,./~ David C. Fitterer Level III 001 ~ ( A.~-rC1J) "2-'1100' ~ Sincerely, IntDrmallon and stilCemllnls in this report are ~rMd from rnahlriolJ, InformaUon ~ lIp8Clfic:atIDm 1umlehed by !he eIlenl and oxducI8 wry 8lCfl1'tlsslld (tf' Implied Wl1~'''' as Ie the fitnea oI1he monrllll tested Or ~Iyz&d for any pilrt1cu181 putpDS(t 01 un. TIll. ~, is tI'le OOI'\rJdentf.J property of Q\1r ellenl and maw nn'IM IlMI1lr'1r :vtl.",.,.... ..,,__ T~I. ......... ."..11 "AI"6 ___....._6.. ........ ...... . TOTAL P. 03 . d000 11:49 P.01/03 ~-~~ r-'- o..~"" AIt"" .~. ea..uc:IfIIrt.. 'IllS........ , . .-aDD ..... UN .122 Ill. 1. 'I. ........... fa ./ ( "FAX COVER PAGE 1":... "' DATE: -Od- 2- C>o ~-S-OOJ TO: -"Bob \!y.t~~^~. FROM: --r~ ~cJ,J. FAX'; ~5~- ",./47 - 4ZLlS" · NUMBER. OP PA~ INa.UDJNGnDS COVER.UlltiK: ~ SUBJBCT.:.. ..:Fq,.,,~'~:~~~'.+'We1cl .Je~.\-. ~,.t -., ~~..,tY4i#.-;'.:~' ~A:i~. ~~~, j k :3 ~..2.. ~\.. \- · _~~lH ~'" -=t>li.Ase LA.-ll ~~.. ,.,-., IF THIS FAX TRANSMIlTAL IS NOT COMPLETE, PLEASE CALL OUR. OffICE AT 651-406 .~OO. THANK YOU! II ,r .J-d000 11:50 ",.--.. DOUGLAS R. IVERSON. P.A. 8550 VORK ~ve_ so,. EDIN4. MN 55435 (&12) 920.2330 FAX (612) 92G4493 FAX Da.te: October 2, 2000 To: Tom Sand (651) 9OS-3678 (612) 920-4493 From: Doug Iverson RE: WAREHOUS~SHO~OOM WBNSMANN HOMES PRIOR LAKE, MINNESOTA Memo: .".-.. Enclosed is sketeh SK00930s showing showing an c:ctcnsion of the bearing pia Ie and and weld for the three joists in your fBJC today. I have usumed that the joist relationship to the plate is as shown resulting in only 1- of bearing. If the channel that I have: shown caMot be installed as shown, please advise. If the reason for Daly 1" of bearing is because the plate has been set too far back from the wall edge. we may have to extend the bearing plate forward instead. Please can if you have any questions. ,r"- P.02/03 @ _ -d000 11:50 P.03/03 ~ DOUGLAS R~ IVERSON, P.A. Structural Enlineers 6550 York ~Ve"ue South EDINA. MINNESOTA 55435 (612) 920-2330 Fl. (&12) 920-4493 JD8~..:J5M."". Pill.' L" If L S~IIT "'O,~ k. ~ Cta. ~O ~ 0' CAl.,CUlATt:D.'--P2..' DATE Lola. 1 ao CI4ECICED If DATE ~~.""'''l~'' t;..~~WE'..a~ .~J- ~V\.... ..l:~\~\-~~.~/b~ 12 \N\~" ST\JlOr /', PflC.l 0 ~ C 5... "..5 " l)- '10 L~"T1-UO ~ !aM.""''' L L,.Jc:.-r-M .~) Sie-.~'" t-w\L So'-.t'"S EMeaQC&.4 ~ ~M IN' \AU~ ... 4. '''''1'0 C6--.1c-n.C,T'L Q.Oa..lO ~L"~. .r-, ~lIl.l" "'.1,,... TOTAL P.03 ~!J~\1L"" (2 /' -L' / ' C / .......... \-r-t! . /' / . \ fj6,y,S c 1'-' 'j '--):.:7>1 ) fr I K- -/' t,/ / .', (' ~ ~~ ~ iHv<-i..J~. f~ GrtWtP~ o.K. ~ ~ ~ .~ G~.r4 ~~~ F,~"LA'N;:: C;;t610~. ..~pp~ ~?z- ~J-b. t:::rsRNecr D(a"t=.(A.Jc;;. 3.nxy tJe>-o m~~ ~ ~ cE ~ .fJA.Jt<-5 ~r/r>-fJ~ HlJcp u/6;<J ~ ~ /~~OJUS. ON Afp ~. ~ A-!C.UPlrS uWls~6~. ON~. c;vJrs, J' 6v9r6 WrU- {;v(Af0 T/ffV Z;~ -~ LOz- ~ ~$ ~CG. ~ l.u~~ CrVUJ(/p.rTO Cb ~ur-A-~. '- St ~I'''-. - ~,'-'~ ~ ~b' ~1f1' ~<:;~ 10 "".~ fl4t t.S 6[(~(L> ~H-- AI (<. ,~5A\ JOur5'~ ~/~ . /f~f+ JtI12-tzn. OCG..p~ vi' Sizes ---t6, O,J ~ bl<- F>a- ~S "C.q '~ ~VV\8\~ ,/ r1tJ,\L 1'l~b>(l",,; ~N.fL- v'ttJ ,q,'\..~ \(U..\ 6Mr,t0 -:2 fl"~5 ~~ f'~,.vllvv'-J Y<5(){L{;\Jl{., M~ No p~(}l.;> h~ ~ ~~L~ ~1A\t2-:; ~6 ~~6- .tt 5 ~~~ 'S'c-AlS \&--\! A-N ~{6L6. t-\~~ ~(~~~~S ~\-r ~Of'>S ~ LtG~(~. -21211211 14: 47 P.el5/el5 '4745 South Robert Trail Rosemoun., Mlnnasota 5$068 An~it 612 423-' 144 . Mne.'( Noune: { A..J '<.1\ ~ t 01. ~ COl,IICI r~r~nn_.___.,'__~.~ ,... .' ~ ~ f\._~ rh"nt N"m"f:.":__..,~~., ~.(~) -..J" If ~ 71. I 7 t.J,.rtS: ~o...~.lr :~ ~~~_...-.i)_~.__ Chy~ k~...:.~~)~ Slale:: _Wi- lip Code:; ~_____.. ^ddn:5S: ^eeCl\lnt Nnrnhet:..._.._..... ".. u .... .. Ty.,..., business Name: ~-..-. \. ~_ _ \\ ~'''' , ~.LJ~. ~...,__,_........ ~i'c ^r.1c1rr.IIl~; ___,.......... ...._... .. ..... " Device Localion: ....:fr\.~\... ~ ~ _., Isolalc5 Whaf Sy~'cn'~ ..._....~........ _ ...... Make:: V ~ 'l k:" <... Model: q 1~ ~L Seri.-I Number: ......._............__._ . . ,.. . I ~i7.f": 1''7... ~.____. TelCt [)..~: ..... ../,/' ./",./ (n!lall DILe: 11. L-z.. C) Overhaul Dale: Line Pn:SSUR .t tjrne of test: pli 4 1-1,t.-. .a....:."'::' .. 'I., i rre"'e;~ii~ r FI('~'~'" C' JtelicC V,lve: r-nj;;i;ci'~i ~ '. .~.. ., .. Itr.rhll:ec1 Prr.~~1II t". 2. "iet UClt "pcn , Jl$i.( Check v.tve II. : .~--.'_-.-._..,__ ...._._... '.a CbeQ V.h'e 112: Annual T~SI I. Le.k~d 2. Closed ,"i..ht .~ ], IlP "'..r I. l~;tlced "..id 2, CIGsecl 'richt ~J~~ We " .. ...' C'e:a1U:d; == .RErlaced; Di,e r,~: . -:-:- 'sJ1,i"1 : .:;C.:, _ Ouide . . .' ;"; \~ . 1';0 Jtc~inEr ,~, ".'~. . ";;" .,,\~:.t ... HII1IE PIn . ,:;. f ' ~ ~..! ~:., ~~:. . Selt " ~;:...: . ,t / ~;..:~" '~:' ,",. D11rhr'llm .~' ~.Other, describe . . ::j 8~~~,:'. .' . ..~~;..t;~,. :' , I ~ ':~ : ~ ' ., . .,~., .---.... --.., (:If'.;,;~ci:.' . =.= Rerl=u:.~d: ___. r>iJ;c. npt'....l tlba:, Im&'.... =~~.:~ SI" 'UR __.__ I)inl'hr:l~m, I:lt..,,: ,_. ,__ _.. "rl't.r Inwr.r .__.... ....i3ra':.;;n~i.l. 1;","11' _ ...._..._ "1'1'''1 hl\Vrl .~~~'i'~' . .. "Pllf"\r Ih\&.t,r' ~i';~(~~I" 1c""'f!I -.-... ..... ()I'I~t. Ik:~(~, ihC". R E P ^ 1 R S Clc.n~d: _ Jlepl.e.d~ Di.c == Sprit11 _ Ouidc _ Pin R~lairu~, Hinllt Pin _ Scat _ Dillphr.a'" _ onJet, describe !. '..i.I' f'IIDte: AU repair, 10 be IT\ildl! --ithin len (J 0) days Dr C.Hed tut. . Fin.J Test Clo~ltd Tic"t IlJ' Closed Tilhl . OJ1r.ur.c1 nl p~i,1 ned"ce~II:;.~~;,';~.. ., psid nor abovr it cenilied "met. _ .. Siancd: rf~-~. Q..~-M resrto By (Prinl N.",c): ......M _ \+ "-..- :omp1ny Name: C:,.~.,...,.. L.. -. ~ \ \) ;.... '!): ~c; \11 sl!l:Unns of t"h~ reportlh".' he completed. f.._.__ r ) ~i"n .nel .h.11: I )~yier, I'=-K. D.'I:: 1'3/0 I Ccu1iCicR.irm Numher~ Liten,e N\lInl\~r! __ 0 '-~_'}_",\ " .~ n. ., TOTAL P.05 . :i91 08: 16 6123226147 GENZ-RYAN PAGE 01 Fax To: ~~~;WS-,,~~~~.__ Co; ~ ~ ~ .. Co: Genz-Ryan Plumbing & Heating Re: Phone: (651) 423-1144 Date: Fax #: (651) 322-6147 (651) 322-1469 Service Department o Urgent D For Review D Ple..e Comment D Pie... Reply o Pl.... Recycle COm......ta: I( f),.)'1 I It,p I;~~,I ~er /~#&.....,.".. h"tIt. .if~ 4 ~,r - ~ ~"dK" , --- --..~. -- ..... ... rI NUMBeR OF PAGES (INCLUDING COVER SHEET): 7 ~991 08:16 6123226147 GENZ-RVAN PAGE 02 t-'.Ic:1J I NSTA.LLATION INS.TRUCTIONS LF24-1.00/400 UNIT ......1f18 &03,mM MID S~-A. .7 '1l'm)T~ l..llJ'RIbIl.ItOll. Ulna U,8.A. JT~..:.~f ~_nta Unit Dlrnenaions , . . . . . . . . . . . . . . . . . . . . . , . , . . . . . , ' , .. 1 st\ippi"g '. , , , , , , . , , , , , , , , . . . . ' , . , , . , . , , , , . . . . . . , " 2 AequlNtnBnlil . , , . , . . . . , . , . . . . . , ' . . , . . . . , , . , . . . __ . ., 2 Unit He., IrI8taI~ ' . , . , , . . . . , . . . . . . . . , . , . . . . . .. 3 ~ i \lwtl1Iian Air -,..... - . . I . . . . . , . . , . . . .. 3 Roldan or Induced Draft ...., . . . . . , . _ , . . , . . . . . , ,. 3 """ting ....,."". - . , , , ' . , . . , , _ _ . . . . . . . , , . . . . , , " 4 Leak Check . . . , , . , . . . . , , , , , , , . , , . . , , , . , , , . , . . . . . ' , 8 S1art-lIp Oper.-ion . . . . . _ _ . , . . . . , . . . . . . , . , . . , . , . , . .. II Heating sequence at epetallon ... _ .. . . .. __ . . . . . .. .. '1 Ignition Cofltroi LED ...,........ I . . . . , , , . . , . . , , . . . . " AdjuatmeAII , . .. .. .. . .. _ _ _ , __ .. .. .. .. . __ . .. _ .. . . .. 12 Service ......."" _ . , , . ' . . . , . , . . . . , , , , , . . , , . . , . . , , 3 Typical Wirt"l CiacJ'..... , . . . , . _ . . , , . , . . . . . , . . . . . . , _ . . 14 Elec:trical CO""8C'Iiorta ',..."......,.."""...... _ 8 Template .' _ . . . . . . . . . . , , . , , . . . . . . . . . . . . . . , , , , . . , ., 15 .. Conn8Clton .. .. .. . .. . . .. .. .. .. .. . . .. , .. . . .. ... . RET~NTHESEINITRucnQNS FOR FUTURE REFERENCE JI ~ Do not atore or use g..ollne or other flllJllm.ble vapore and liq- uid. In the vicinity of this or 8fty othw appliance. Inatallation and service must be performed by . qualified in..ner. Hrvice agency or the ,_ euppU.r. A WARNING ... A".... e WHAT TO'DO IF YOU SMELL GAS: · Do not try to light .n, .ppllance. · Extinguish.ny open "ame. · DD nat touch any electrical SlAfJtc:h; do not uae any ~ In your bu~dlng. · Imm8dla.ly call yoLlr '8. auppller from 8 nelghbort. phone. Follow the g.. suppU.. .r's in81:ructiona. · If yau cannat. ...-ch your g.s ."ppller, c.1I the fire d.,.ttmenl.. .I "..:. f~. . :~ ,.- J 'I~ .<[1 "1 .1 i ~ I .~ ~~:; . .t~ . (,.: '. 'r~ . i':' ~~ r:": H: ,.1. . .~ '.~ .tJ ~''; ~r r;-; ,~: ...il~ . III( t. . ,.:! TOTl=l. P.03 ...':391 08:16 6123226147 ~p''''' ...: :'. " '~':.:. .... .... '~r :'.: .:~..':,"<,:..}.::> ... _I 1.:~H,t.I!' ~.... .':: .... ..... ..... . .:' .;,,';-: The .....r 18 camplele'y _"'bled with the following parts pllCke::i intlde: installation and aperating i'WtNdims. warranty certificate. and flue transitian ece. Check the un" for shipping damage. Tl'!e rscei'Ying party ahoula C~"t.c:t the lut clrrier immediatety if .ny ahipp'1\9 damage is foul'ld. ~~'''''ta'''''~GA'' ":.:~:.,~:.: ...:.... ,,' . I Inatallation of Lennox gas unit h_ters must conform with focal building cod.. or, in the abse"ca of local QOdes. with tn. current Na11on.I Fuel Gas Cad. ANSI.Z223. , . Installation in aircraft hangeMll'T1U8t be in accordance with the current Standard for Aircraft Hangers ANSIINFPA No, ~9. InataU.tion IrI parking structure. must be in aCCDn:lance with the currant standard for Parking Strudures ANSIINFPA No. 88A. lnS1allatian I" f'8pair .,.rag8. must be in aa:om.nc:e with tne current Standard for Repair Garages ANSIINFPA No, 889. Authorlttea having jurisdictiof1 should be consulted before inetaflation, AJrforcamtution and wartilllion must conform to the rMthada outMned in ANSI 2223.1. ..cion 5.3. Air for Cornb~tiart and Verwtilalion. or applicable provisions of local btAldi~ ~. 1" National Fuel aas Code i. available from: American National Standard InstitIJte, I"c, '43C Broad.,ay NINr York, NV 10018 Thai. I.Inlts are A.G.A, (American Gas As5~.tion) design oertified. Th_e unit neaters are certified fer Inatal1a1ion to combuatible material as liated in table 1 .nd on Ltnit rating ~.te, Acce..bili1y 8"d I.rva clearances must be obleNed in addition to fire prat8ctign clearances, All electrical wiring and grcund for unit must be in aCQordance with the regulations of 1he currEfrrt National El8c:trlr; Code ANSIINFPA No, 70. The National Electric Code is available from: The NaUonaJ Flre Protection A880Ciatian 470 Atlantic Avenue Bastan. MA 02210 fiiequlr.menta .. ca. . '. I Thelnstructiona are in1ended only as B generaJ guide and do not aUPflraede lacal codss in any WIly. Authorities ....vitlg jurisdiction should be c:cnsult8d before Uallatlon. The insblltation ml.lst canmrm with local bUNding cOd.. cr In the absence 01 local cad.., witl'! t~e GENZ-RYAN PAGE 03 P,02 currem cod. CANlCGA.Bl.I.1 -Installation Cod. for Natural Gas Bumw,g Appliaras and Equipme"r and CANlCGA-B148.2 "'Inatallalion Code for ProPBne Burning A~.nceil and Equipmertt.u All .tectrieal wiring and gl'OlJnding lor the unit must _0 comply with the Canadian Electrical Code CSA 022.1, cunvnt edition. These unit h..... are C.G.A. certified tr:rtt'l! cI~ fa a>>mbuSlibJe rrRterial isted an the rating pia" and table 1. Adequate durance stili be prI)~ .~urC the ~~ianc. and iIIQftJ air openings il'lO the carnbUstior1 chaniler. Pravision shaI be rrwJe for Iervi:e 8CCeSsibiity to the heater. NcI8 that fire ~ ~ may be ~ to ~ additional ~ for I8Nice and acc8i5ibillty, PUBLIC GAFlAGE= 1- In a storage area, cJ8818ftC8 'rom helltel"ll to combu~lbl. mate,.. m.,.t be suct'! ''''.t the materi.1 shalf r1C~t attain a temperature above 1 so-F by contln",ou& operation or lhe Imil 2- Eight feat minimum clMrance from the ftoor to the bottom of the h.lter r\'1Uat be maintlUned. Refer to the CANfCQA-B1G Codes. AIRCRAFT HANGER: 1. In an .re. whare a;rcr8ft aM houaed or aerviced, '0' minimum c1arance from hlgh..t SLI rfece of aircraft to bOttom of tt. heater muat be rNinrai"ed, 2. In other .,.5, 8' min Imum clearance from the flcor to bottom of heater mUlt bIa l'TIBintainecl. 3- Heaters aPtQuld be located 50 U 1D be proteclad from damege tram aircraft or other appliances needed for senricinl of al~r.ft Refer 10 requirements of 1he enfatcitlg autp',arltl.s. In 8 confined area, thR h....r mullt be inatalled in accordance with the CANlCGA-B1G Code_, Be aura to c~k with local code. and ordinances for IIddllionlll requirements. TABLE 1 UNIT CLEARANCES 'd_ ....' ., mm 1S2 Page :2 . r'~ j : ,. . I :,' ~ ~., i' L~ ~.1. ~~~ , : ,: . )~ j',' . ':'M ..;~:~ . I',,: ~ . . '41 . "s:t: '0'" ;l: ~!:' ..,: :} .:~ I '; f: r' >;,: '. .~ ~". .~ ~ ~I " .', " ,.'i ..~ i ~ .,~ ~ ~' ~~ .. .;. 5 '. , ..;;"i ...~M ......~ P.12:l1/12:l2 JAN-12:l3-212:l12:l1 17:1215 .. TO: WE:~5M~~~ I'1RI~ OF"rlCE --..- '" I rll I 1J....wc;.r;.C,Lq r NO - 981 P. 1 '~745 Scum RObertTrail Rocemount, Mi,"nesot8 55068 Area 851 C23.1144 Fax To: Fram: ("/~ ~.: COI Gent-Ryan r'tumbing & Heating Date: 'hone: (651) 423-1 '44 r:_.~ (651) 3~..s147 (651) 322..1469 Servic:e Oepartme"' We: [J Urg.llt 0 For Review 0 'lease Cam"'eftt [J 'Iea.. ..,IV C Please Recycle COIIUII.nts: ~ u..4 ~,4;r ~-- ~~ t./, ~( ~~ ~.-Ik.- ~~~ .. NUMIER OF PAGES (INCLUDING GOVER SHIIT): '2. \ . , JAN-03-2001 17:06 P.02/02 I"IV. '='~l ~. ~ 14745 South Aobe" nail Resemount, Minnesota 55088 Area 851 423.1144 January 2, 2001 Tom Sauds Wens eo, Inc. Re: Fountain Hills Tom.. No verbiage as we discussed. in the manual. Here is a suggestion: THE ABOVE ''RAM' ALARM WILL SOUND WHEN CARBON DIOXIDE LBVBLS REACH 800 PPM. D" ALARM SOUNDS, PLEASE OPEN DOORS FOR FRESH AIR AND CALL G:ENZ-RY AN PLUMBING & HEATING FOR. SERVICE AT 651-423-1144. The a1mn is not adjustable. I have ordered an additional alann. which should be here in a couple days. We could go with different second alarm that would be louder, and take some extensive wiring. But the liM almn has a silence mode that can be aetivated ifit would ever go off If it gocs off tenants c:ould silmee and call us without customers ever knowing. The alazm is only iDc1icating an indoor air quality problem.. Dot life threatening. I will fax install manual to Bob Hutchins. Please call with any questions. ~~- Todd Boyum, Genz-Ryan' TOTAL P.02 01/20/1991 15:53 6123226147 ,,_GENZ-RVAN )~ELlL\n Y"TtN'SUK) bU ~ ~~ P~st-rF PAGE 01 . . 7671 CARBON DIOXIDE SENSORS MODEL '4GS Phone .. Fa.' F.t Ri.......u.ua "': :-'~.. :~f,~.';:~..~ ;>i" ';.,:....~, ), : ~~ ::.. '.' " ,...:,: ~' :.:"" W1_:~:~,>~:,..:. ~.~ "~?; ':"~.' .: ~.<:..::.~,: ';.: " .~", ,.' .;"...,.:: :'~- ..'~<: .~~:. > . ,'. ~~, ~..... '"'' ,...1$"..., .". . ,. , , " ....,..... ,"l.,:', ,,-..:-.. /',. ... .... """ '. . I, I . .' . . ';.'" "'.'.1 .. 00 . ,. '. I I. I ':. "1 '.." , .' I I . . I 'I" 10 . _0 . In T (em) 0 I..... ...) It loW' ~l If- U. -.. CLIO ' 4C1S Senior ",. T -I.... L.... ~ L" ~ I'. L-I.,................ ,.--- (''''.')-----''' cJ../L c..=.. ~ IWMI .......... ~ '......, r-y-- :-..I::"I UDiJ~~ 1~00000j "IIIUii r ..... ...... DNL" L . ..... 11olO YAC ... 1...0 VDe (Nt! 'a1...V) MIIIetI 0uIput c-.. ..... ~ ~ ... 1M .... ... co. NIIte: COz eanwr.n Md 2A VACIDC CantlNlrt ... ........ 1ntiItMII,. . Duct Alplratlon Box (Optional) ~~: ~':':::".:. : "':', :: '! . "J " :' ;,: ~ ~ "~ ::,' ,I,~ ;,.,.::: :" > .:: ~ ~~' ,::"..~:~ ~.':;,:: ,,}::)~. ~~>'~~~~"'~~''':<'~:~'I',.'?r> .~. "<~'.' ....'.>' :.1, ...:" ,,:" . ~,'" ',: The .QI' =-nlOr Ihould be maumed in an area '''at is reprelentative ot the conditioned apace to be monitored, Avoid drafty wlndo~. and doorway. d1at might tend to drrUle the atmolphere bei'1g controlled, MountinG height Of l112 to 5 t..t (1.2 to. 1.5 m) I. r.commended bUt is "at orltlcal Ilno. carbon dloxld. diffua.. rapidly In air. The 4Cl1 00111.. fGCQry conflgl.lred for 4--20 mA anaktg output, "voltage output il requlrwd. movln; the jumper on th~ bade otu,. unit from If'. to Y will chang. the OUtputlO 0-10 VDC. The \loltage output may In turn be ohen;ed to 0-& VDC. Ihe ..nlln; ,.nge adJuated, ar,d the (optional) rtti.y .etpOint changed by UI. of the programming k.y. on the back of ttie 4ClS and ita optic".1 LCD display. Units with no displ.y wUl require the CA.....KIY calibration key- pad for adj..,ltment, A.fer to the programming manual lupplled with the 4G8 far configuration and calibration lnatru;tJonl. ' IIODI!L . ...eRI.....DN 4Gl4lc.oe ....., WIth analog output only ,-~::.::-~!.~fi;~~J . ~t)~ Ie..., .n. ut.. ., an ..I.y , ".. ,'.,:' I" I '"1" \' " , ., ca.......ICIT .."""-I(IT Duct mount IdI fltr 4G1 ..naor (0" "'101' ~) Impact ..mp.intl tube kit tor 4aB 8"'''' (order ..,..., . MptIrately) Cell"nft~ .,.-s with cabl. IIId connector f. ~. un.., I' I ",,' . . ," I'. '. "'. . :.", I CA.....ICEy .' to. . . ,,\. I : I . .. . I ~;...;,.~, ':' '~,,,,,\~,,:';',;,,:>!,:.~;:,~.> :t.~':..Z" :;.\::'7"f~,'\.::,;',,~, ,.~::: ~-:;~'~;~;"i:"':.'~.."'''~/~ :.~: ;j,.~\\t I ;(":';,"'.~',;' .:......: ; :" .,.. , 01/20/1991 15:53 5123225147 I I ... ' ' \ I' . . , . l ~ . , ", ' ;.', I. ,0 ); , ,I ii i~ Ii il I II :s II = I, I Ii , . '~ ~ . I GENZ-RYAN PAGE 02 r: t;r ~ t .. I r ; t I iit I' ' I i!i" ,. 8,'i'i ~ 1.111= i tf~ 11.1:i. III ~ ~ !:S':r' . I r it.. · .,- IF , ill ~ , -,'iii i llfti: i , .1 i . 11'!. I.f r t I r l. f I: f · r I :r- ill '. ~[l J fr.-..' I II 0 " · L ,,[ ,gll! llllr: II " ~ : "rll,., }!,i ! "t.! '.. tlJ:.i , III', ,ll.fl~ , i= , ':;' " ~ - ' ..' .: . .' ..,.... "II.<Jll~ :t1'lltl.lilt !-' It.U' I ~I. l!J..,;II~IIIII"ohr:: III ., J It .-1 I.. r II ~ t f [ ill till _,I I-I' I la'l il. I h','1 J r rli" .iJI~l i!t'~llrl! I iJil'll &1' ".til t. tf.. r 1.. [ I t I r II' ",i III 11 I a ., I~ r 1 I' o .111 ,;.,t(~,l Ir . It I. , . " . e..... _...._ y.. _. ,I' ..'_ ,.. r I . . . ,', . ,... " . I, I I'll a. \. .. :....~ '_'~. <r7i:'J_ ., -I I,. r. ,.....'.l,..,..-.~.. ,.0. -. . ~- . ..' ,.. . . . p ___.... ....__.... I , ' r Wi i:' ~ JHI'~fljf~I'lfl'l'ijff, 'I ! , 1 ' ! ' It, Jill' I (Ill .t I. i. ('!' ' ~ '=- 1I-a&'lil r "'~Ir ". · ~ t ~I il i 0 !;~~, 11!~i'tl'!I'iifll-.I~ll - I J ~!' -~ 0 c"lllll i' .1. ~ 0 ! II ~ i 11 "lfl.:il~l: ~,':' ;:I ;. . I: t' III f · -l.ll f II ( , , i j '1"tfl'fIIU .... 'ft. (" , 11 ' " ,!-I!froIJ!,~~ I,.!,';, ,': I '. 'tllta ~ill Ill' I I I.. ' , ' : 'I~i .o~I;lt Ii ' o - I : 0 ", ,,' ,''.: 0 :J ,II i; 1 f ~ I' ; ~, I i ~', "::, " " ::-:0,:: ,';~::'>;"',':: ~:,::, ~,:, :;'; ...;,:~II~~J. il t ~ till. ,z ~ 1_, ',...,' ,.': " 't ~.~ ,.:"~ ',: '.-' '.. ' . '~~.:;:;:,;"::"". " ':'. :.:,: rl C'r '-I J II I, fit I' ,l:l ,,' ' . .', " '.~" . .', r ' Ii .. ; ,.:"" ~ ,', " '.. ::'. ,!"'~:: '. .'."~: "'.-,'~'~. :" '.' "'~' .;,. . . . ",., ", ' . .. ,.,'. ~ '.., , . ..:..~: : .)' ", '.', , ' . ":~.: )9E2'e 0Z6 2't9 S~ b:J~fo.NIW WdEE: za '00 ~ 11 J.~ . >> ]' .. OS I. 'I ,'01.' 0 ~I o . · 01 I. . rn . . GENZ-RVAN PAGE 03 . I ...~: '. >" .fl'f~ ,f IS !I"ii"f if I !t .' flilHr!li Illa'{'IJr81=lw g ~,lll.l II JIJ' ~ I ~rii, r"ll ,a'Z'llrf'IIIJ .Ht.i1~U ,f, l!lh.fls'.. , ., .. .,. .::,..... -f1lljlfi J.II:f!II~J.~J~II.' , I': 1.11 Iii IJ' trf'rii.llJlr ~ ' 11~I!tl ;.!~t,ltl;Jlfr[ I fi~t'I' IJI [It;lll~flt~lfiIJf! B flit J J I I'l~-I i ;~f I ,~!ll:i~ fl!l III. I'Jfl! I '- Ii' hi ~,.i' '!.h'.t ..I i ,'. rn. . . ~ .' l! ~ · . ., nn -I' . , ~i i ~5' ~ . ~ i'.'" s. ,~i' - . \ 01/20/1991 15:53 6123226147 I IfJ Iii o . . , " '1~1~!(II~llllllt:1 f i~liifl '1 till ~ If.r1'!r'lltts. i i ~ riJ llllr- ~llf,PiJI;' :I ~ ~ ~. If 6 1'1 I ~ }JII[flitil}J&1 ' .r t . hn~flJJJhJI ..,.., ." . JJrl!l~ '.-. tfl ' ': " , ....; ,; I ~ f r r1 .. Ill: , . . . , .' ' : :'.. , ~ ... . '.1 "'1 r ' . <:./:::....:,:.., ',':, 'fill~itJ!.:(r.- . ~. ::.:; : '. ,:' ..1~I.lI..II(tiJ . " . " ....' . f. C I t :t" I, . " . ' . e, r' ..a. .. ' , ' I ~lf ~ ~ i I r r U IJI .t. ,.t , '. I 'fA '.,1 I 9E20 826 Z19 S1dW O:JIt:fI\NIW ~: 2B 00, t t 1:)0 .1"1-tl~~ \t l1...... Lf' Fax To: ~... Co: r-:-( _,' ~ /J Prom: CU~ Co: Genz-Ryan Plumbing & Heating R.: Pllone: (651) 423-1144 Dat.: Fax": (651) 322-6147 (651) 322-1469 Service Department o Urg...t 0 For R.vi.w Ll Plea.e Comment 0 Pl.... Reply D Pl.... Recycle Co...",enta: fu ~~b~~ ~~ Ails - tv/~5~tf',. . ?ts ~aU r"-Y ~~5./ ~---rS" ~ NUMBER OF PAGES (INCLUDING COVER SHEET): --z,. 10 39\td N\t^et-ZN39 LP19llEl19 LP:91 1661/80/10 ~ROW DATA Model Air Volume CIJEnecUve Throww No. ofm u. '_I Mtlter LF24- 100, LF2&-, 25 1900 895 80 :zo LF2&-150, LF24~200 2200 1035 85 20 LF24-2l5O. LF24-3XJ. 44tOO 2075 80 24 LJ=24.345, LF2A-<<XJ lDl'htaw 'ermln.'.. whent velaolly r..ch.. 511 n, (15 m) Der minutB. NOTE - ~ hcrtzElrW a.-. on WIlt III1tt1N a YlWiBIan In fIItIW McI &pnIId. DIMENSIONS.. Inch.. (mm) I ~............ ................ LP2..'00I.12.,~150.... .zoo. . ...262_....,..... .... ~ ...". tw. ...... "NOTE - Two SpJInuIa.,. ftJrrIW-=I en ~-'OO, LF2o$.12$. LF24-150 8f1d LE24I-2QD 1TlOdeI&. . Four .poII'1U'. .,.. rumished on LF24-250, lF24.3OC) LF24-3165 and LF24~OO modele. .Furnished 01'1 LF2~-250, ur24.300, LF24.3.&5 and lF24-.00 Mod.'. Only. r-c-, ~.~ ". '~,\- . --.-. . .-i I .........' "".9" ::~L' . .....~. , u .". .l '~ ~ j ; J. :1 ADJUSTABLI! LOUVERS ~ .~ : ' ...( ...."1 Jf I ~~. ... J ~_.l- "(I U ,aI: r.' ~,-~, :,1_ '.. ~I: ..~ 1 HEAT EXCHANGER END VIEW INSTALLATION CLEARANCES Top 8lnche. (152 mm) Sides S Inches (152 mm) Rear 18 Inches (457 mm) Bottom o Inches (0 mm) Flue 6 Inches (152 mm) NOTe - Provide adequate clearance fOr' Hrvlclng. 318-16 SPOTNUTS FOR UNIT SUSPENSION eLI!CTRICAL INLeTS rA ~I H INDVCED DRAFT 8LOWER GAS VALVE SIDE VIEW Model A 8 C D E F 0 H No. In, mm In- milt In. mm In. mm In. mm In. mm In. mm In. mm I LF24-100 31.5(18 795 32-3118 817 20-3/16 5U 10-1/2 287 19-1116 484 11-7/8 30' 3.',4 83 7-718 200 LF24.125 lF2...160 7.7/8 200 LF24-2CQ 31.5/18 795 32.3116 817 23.1/8 588 10.1/2 287 22.1/115 S80 13-1/4 337 3-114 83 8.11118 220 LF24-260 31~51'6 79S 32.:JI18 817 41-1/8 1045 3.11/18 97 40.1/8 986 17-112 ~5 3-112 89 8-11118 220 U:24-3DO 8.11/18 220 LF24-345 31 -5116 795 32-3116 817 41 ~ 1/8 1045 3-11/15 97 40~ 1/8 986 17-1/2 445 3-1/2 89 g.13116 248 LF2~ 31-5116 795 32-3116 817 41-1/8 1045 3-11118 97 40-118 986 22-118 562 3--112 89 ;-13/16 248 LF2j 1 PAn.. . ~ (;0 39~d N~^~-ZN39 .r LP19(;(;E(;19 fJlTlj) Technical LP:S1 1661/80/10 ,<11 14: 46 P.01/05 WessrnaIUJ HOIDes (651) 406-4400 Phone '. .:.. (B51) SOS-367,!,,",~)a,.:_.. 7 '-'."f""~. ..,.;-~ .,:.. . ...,;. ,a..!- .. 16.$1'... Dr. Salle 811" . Ea.., lfIN SSJ6~ www.we..."l1z....com 1)a.t.: JAt-{. IS I lDOO Atteldloa: Bob )I~/"/'/;'f" Fl'Om: ---riM ~"'Ml>> Nu.mh.~ of pag.. (lacludlag lids cov.r): 5 Commellt(.): · roLl"~'.LI )j,IIJ &(-br... T~f2.~~IJJ l<.PL ,~+- .Jl 14:46 P.02/05 14745 SoU1h Roben Trail .RQ$emount. Minnesota 55088 Area 65' 42,3-1144 Fax \Ot'\ Sp.,,~:~'~~~) To: ~o~ ~. (QC' :~~ l~lu.. \; . Co: (q~W 'y.~-;~,+k" .. ,S-I- ~~- ~'-" Fr.tat: ~A~ ~:~~L \ Co: G~~Ayan Plumbing & Headng D.... P~M! (651) 423-"44 '.1; (65') 322-6'47 (651) 322-1469 SaNies Depanment C U...."t ~ Par ~ ~ 0 '1__ C;........nt C Pleas. "-Ply a p,_ Reqd. ~ e'~~ ~ c...~ ~ ~c.... ~~ ~~~c.~~l\-~. ~"'''' Q~+~~~ '-0-. \ \ . .' ('-.n) 41.. ! - J 'i "t ~,,~ ~~~~'--. \ IIUMBER OF ,AGU (lMCLUDIMG cOVER SHEET): 3 .d1 14: 46 _del 16:25 .4 . T\AJ I N c.; 1 I T I I':.,:) I 1 NlJI P.03/05 I wn I '-'''.1 I "~LIIIW '-'\111-'\11 cu...,. . 17 IG CromWlll Avenu,. st P,ul. UN 55114..1nl 18S1) Ms.-11G', Fax l1S1) 151-7341 FACSIMILE COVER SHEET THIS MESSAGE IS TO: THIS MESSAGE IS FROM: ~ Rlesc.,h \ Name Ja V ~ Q/\.SoA Name ~z. - R."IQI\ Ph..r4~~ a., ~~~^~ Company 1- IO-~OOJ Date bs-I- LI-~3.. ~ Phone Number (6S1) 6S'1- 7'-+03 Phone Number bS ,- 30)d--- bL'+7 FAX Number (651) 669.734B FAX Number . . , MESSAGE: Ma1t} Here. ..5 ~t. rt5\JH- crt ~e WQffr '"'fes-f 1-'ot~n 0" J(1.^ g~ :r~ YCl~ I,Guf., OrtV ",~e.s:f;b"S plSQ~e cwrtacf hr"f f'Jft -f'/, e- OtboVe.. fllAltftl:,#lr_ ~~t y~ C}7~ This mes..g. includes this &:over sheet and -1- additional page(s). Tft. documanta -=om,..ftYlng thl. tal,eopr transmission contal" col'lftdentlallnformaUon whleh ....8.ny pr'vl18g$d. Th. i"fcarm.tf~n I- I"'.nd.. ordy for the U.. Df the r.I,lent ".",eet abOVe. If YO\l MOVe! receIved thl.ln .rror, pl.... notlfy us imrnadlat&ly.ncI w. Will arrana- tor r.t\lr" of ttle 40DU",__tII. YoU... h.r.by ftallfi.d that ."y dl.cJ..~r.. C:QPyh~l. clJ.trlbutian, Dr the tlkl"_ of MY .ctlon i" "en...ee on th. OO"_"U of 1he tt:IKVpied infounatloft I. etrlctJy proh'.ltad. ..J1 14:47 ~~1 16: 26 TWIN CITY TE5TI~ P.12I4/1215 - ~ , , . . ~PE CTRUM 301 Welt CcNIny bad E2 · St. Paul, MN 5S111-68S9 ~ '51.6~!.0101 · PAX 6S1.'~'.1402 .,.,..spcc~l.cgm LUoM70JtI' ANAL"'S lfDOll.7 1JA.rB.: JtJIlIJlGry J. 2001 'AGI!~ ,.oner NO.: CDLlBCTlON DArB: COURcn:D B'f': UalVJ:DDA7E: PR01BC'l D~SCRl'.: t:uBNr: j'r.pr,i.Tt&lln Ciq Tf!IfiII, 66Z C,,,...lI Ave. St. PtJul, J4N "1 JiI CONTACT: Te~ ScAtrsitlr AN~~J'S Tottd CDlf(oPJJI (C"Ule") (SM J21JB) s.,.r. No.! s..," 'Do; VNIrS l/& ~1::1-3OD~ O/P'jr 1101I01 C'UIII lAJBlDl PO ItJJDOOl. GM1.tJOJ 43.s r....... _lib Dr. AN,u,rS1S &WI 11OIIOJ Qs~r Ab.relll A6I'II' ......., IMt JlQ TOlal C.lp",. 'IICtms w,,,, IJ'fIDlf iill 00 Millili"f'J oj t"~ laMpl#!. ,.,.""" JUtPU' Ilult Total CtJlifo.,.".]Jac1ma tll'e pre$OJf in tls~ s.." At " ctJnCelltnUiDll rJ/ 1 '" mote celb pllr 100 ",illilirel"$ oj .rtDIIJIle. . nab ~~n Juu ~.1Eft review.J 11:1 JIIe/G, kc:blt:td .c~IIN9""'" CCllfI/IletDJIl,u. n. ..,..z.ysu ~e't: ,erfoPWIetl uin, VA II' tJm.T cppmv.J "..,1ttNlal",Ies tJIJIl r_ ruulu .c..., 'IpGrlftl Oli M "ar ree;'iy~~" 611.I;" ..,tI.'1 orhcrwlrflllllr.d. TIle res"ID 'l!pGJ'fetl rellll. tntly ,,, tlte i,eIPU Icst_ ,,,..,. CO/IMt:' JIIe ifyt/ltl. MvC IU&~ fu"'DIU ar c~..t... n'lIrtli..g rltis "epfJn. Sp.~"""" UlbJ, Inc. .",elo"I'" G~pD1'ItlIli1'J 'a prtniJl.. this IIIIIIl)tte.J J.rvic~ for ~... R'pcI~B" W".".. M_rqfiflltl M/~mhio"",1s1 ............... GJH.-.mc ~2447 Ar. ...1IMIl ,..,.nl,... '*', ,."',..... .,....... ". 0W/I',1IIIJIIlq ~ !till) ., ... '.JfIfI4~.- ..." '" /till .....' .1Cr",. ...,ltoff.". 111. A",.,..,. .,nte """...." c"." _/ ~,,',.,n'" TeTRL P. B2 P.O. Box 27376 Golden VaDey, MN 55427 SCOTT D. KNEEN, P.E. REGISTERED MECHANICAL ENGINEER Heating, Ventilation, Air Conditioning, and Plumbing Design Phone: (612)-849-9078 Pager: (612)-901-0675 October 15,2000 To: Robert Hutchins City of Prior Lake 16200 Eagle Creek Avenue Prior Lake, MN 55372 RE: Fountain Hills ShowroomlWarehouse 00.04tvj Prior Lake, MN Dear Robert, As per our phone conversation, I would like to confinn the following four issues we discussed and also advise Todd Boyum with Genz-Ryan. Issue ##1: Outside air for acceptable indoor quality. ShowroomIWarehouse areas are provided with 1440 CFM outside air to satisfy ASHRAE 62-1989 for 96 occupants (continuous) or 192 occupants when peak is 3 hours or less (page 2), Architect anticipates 10 employees and 40 customers at peak occupancy. If you do not agree with this design, Genz-Ryan will install a C<h sensor and alann (set for 800 ppm) to alert owner of1Jrn:.~le COZ levels. (See page 4 - 1000 ppm continuous.) Issue ##2: How will Genz-Ryan verify outside air in the amount of 15". is achieved? Assume manual dampers set on day when the outside air is -50F and return air is 70oF. Genz-Ryan will open damper until mixed air temperature is 58. 750F. M,A. temperature = ,15(-50F) + .85(700F) = -.750F + 59.50F = 58,750F Issue #3: Combustion air for each Unit Heaters. Provide combustion air intake area greater than or equal to the flue pipe area. Issue ##4: Re6ef air from lower level east oftiteS.. Pro-vide a lOxIO-relief-grille (1I2"xl/2'.'.egg-crate). and a IOxl0 relief duct from each office. Grille and duct will transfer 120 CFM at a duct velocity less than 250 feet per minute, Please call (612) 849-9078 if you have any questions, Sincerely, t>>tt l). '?< ~ Scott D, KneeD, P,E, Copy: Todd Boyum Genz-Ryan 9 +8" g 9 b f TABLE 2 OUTDOOR AIR REQUIREMENtS FOR VENTILATION. (Continued) 2.1 COMMERCIAL FACILITIES (offices, stores, shops, hotels, sports facilities) - Application Commeats Estimated Maximum*. Oecupaney PIt. It or tOO ...1 RetaU Stores, Sales Floors, aDd Show RooID Floors ~ent and street . Upper. floors Stqra,ge,rO<?!ps D' ms des d receiving Warehouses Smoku,glounge S~b:Shops 30 20 10 100 25 13 70 25 13 60 20 10 150 20 10 150 15 8 70 15 8 100 15 8 100 15 8 150 15 8 10 15 8 dml person 30 2() 15 20 4-''1 60 Outdoor Air Requirements LIs. dmlltl penon Lis. m1 25 2S 20 8 15 2S IS 15 0,30 1.50 0.20 1.00 0.15 0.75 0.20 1.00 0.20 1.00 0.15 0,75 0,05 0.25 30 Normally supplied by transfer air, local mechanical exhaust; exhaust with no recirculation recommended. 8 13 8 8 Ventilation to optimize plant growth may dictate requirements. 0.30 1.50 8 8 1.00 5.00 8 When internal combustion engines 13 are operated for maintenance of 0.50 2.50 playing surfaces, increased ventila~ tion rates may be required. 0.50 2.50 Higher values may be required for humidity control. -"7 ,. ; . ! /; e..-- L/ L' ,-,. ~\ Special ventilation will be needed to eliminate special stage effects (e.g., dry ice vapors, mists, etc.) 8 8 15 15 Ventilation within vehicles may require special considerations. Spaces maintained at low tempera- tures(-IOOFto + 50 of, or -230C to + 10 oc) are not covered by these requirements unless the occu- pancy is continuous. Ventilation from adjoining spaces is permissi- ble. When the occupancy is inter- mittent, infiltration will normally exceed the ventilation requirement. (See Ref I8). 150 70 IS 25 .<~$61~21~~ribes supply rates of acceptable outdoor air required for acceptable indC)(>rairqu81ity,These values have been chosen to control CO2 and other con- taminantswith an adequate margin of safety and to account for health variations ~ cis, and a moderate amount of smoking. Rational ppendix D. tmeDt~ If the outdoor air con- taminallt eve s.exceed the values given in 6.1.1 (Thble 1), the airshouI~,~treated to control the offending contaminants. Air3<?leaning systems suitable for the particle size en- c()uDteredshouldbe used. For removal of gases and vapors, ASHRAE ~AJU) 62-1~8~ r .""").~~:W;~%D,'0\\f:~,\~',;:d'->'." appropriate air-cleaning systems should be used. Where the best available, demonstrated, and proven technology does not allow for the removal of contaminants, the amount of outdoor air may be reduced during periods of high con- taminant levels, such as those generated by rush-hour 'CD air be delivered to the conditioned space at all times the building is in use except as modified in 6.1.3.4. "'~~()p~dY~!~.~~~flil\Il1;~~)R~J"~B~~~t~9.' Under the ventilation rate procedure, for other than intermittent variable occupancy as defined in 6.1.3.4, outdoor air flow rates may not be reduced below the requirements in Thble 2~U'Cleaned;recirculated airis usedtoreducethe outdOor air,!J,pw rate below the values shown in Thble 2, the Air Quality Procedure, 6.2, must be used. The air-cleaning system for the recirculated air may be located in the recir- culated air or in the mixed outdoor and recirculated airstream (see Fig. 1). The recirculation rate for the system is determined by the air-cleaning system efficiency. The recirculation rate must be increased to achieve full benefit of the air-cleaning system. The air-cleaning used to clean recirculated air should be designed to reduce particulate and, where necessary and feasible, gaseous contaminants. The system shall be capable of providing indoor air quality equivalent to that obtained using outdoor air at a rate specified in Table 2. Appendix E may be referenced for assistance in calculating the air flow requirements for commonly used air distribution systems. 6.1.3.3 Ventilation Effectiveness, E.: Outdoor air for controlling contaminant concentration can be used for dilution or for sweeping the contaminants from their source. The values in Table 2 define the outdoor air need- ed in the occupied zone for well-mixed conditions (ven- tilation effectiveness approaches 1(0070). The ventilatio effectiveness is defined by the fraction of the outdoor delivered to the space that reaches the occupied zone. Ventilation effectiveness may be increased by creating 1.0 v = Corrected fraction of outdoor air in total supply X = Sum of all zone outdoor airflows divided by total supply Z = Outdoor air fraction required In supply to critical space 0.8 Y 0,6 Y = X/(1+X-Z) 0.4 0.2 o o 0.4 0.8 1.0 0.6 X 0.2 Fig. 3 Ventilation Reduction in Multiple Spaces Supplied/rom a Common Source 12 a plug flow situation. If the flow pattern is such that the ventilation air flows past the contaminant source and sweeps the contaminant toward an exhaust, the contami- nant concentration in the exhaust can be greater than that for the well-mixed condition. Ventilation effectiveness can then be greater than that which would be realized with perfect mixing. Local exhaust systems o1perate in this way. With perfect mixing between the ventilation air and the air in a space, ventilation effectiveness is 1000/0, With per- fect mixing, Ev = 1.0. It is, however, not uncommon to find some of the ventilation air bypassing the occupants (moving from supply to exhaust without fully mixing in the occupied zone) and achieving Bv values as low as 0.5 (see Ref 26). Such flow conditions'should be avoided. The abili- ty of the ventilation air to mix in the occupied zone can be improved through recirculation or active mixing of the air in the space. Additional information about ventilation effectiveness can be found in Appendix F. 6.1.3.4 Intermittent or varia~le occupancy. Ven- tilating systems for spaces with' intetmittent or variable occupancy may have their outdoor air quantity adjusted by use of dampers or by stopping and starting the fan system to provide sufficient dilution to maintain contaminant con- centrations within acceptable levels at all times. Such system adjustment may/lagbr should lead occupancy d con occupancy. lcJl.q~lDW' -- . .Il fr"1blviler11~r,@nly.,wi ~~~pr."~~iu..r ...:1:~JJI1....ll~~.-~tYSh~rt-term ltoal~..dJ~.'..-1It~1IDn;''!-...1}...~'11~1l~e~~.piled peFi88t-ta.~j':~fi~6Ilfh.i'i........I~",,!,.+U,~~IMlfl<j'er\ir, ~,. r....A. ...M"....~-JIJ~.PJ!~~~)~..\Vh~n con- I , 1 ~ ASHRAE STANDARD 62-1?89 (j;) ,.LI Quantitative Ewluation. Thble 1 furnishes informa- don on acceptable contaminant levels in outdoor air. This table also applies indoors for the same exposure times. For additional information on contaminants in the outdoor air, see 6.1.1. 'Dible 3 contains limits for four other indoor con- taminants. Three of these arelimitsset_by_ other bodies as dicated in the table. 'Fhelimitfor~.waSseleetediib'as~d (} . . gQt~~tJ.~~,. contaminants for which definite limits have not been set are discussed inAp~J:ldix C. Th.bles C-l and C-3 do not include all known contaminants that may be of concern, and these concentration limits may not, ipso facto, ensure acceptable indoor air Quality with respect to other contaminants. ft~il'~" J I ] .11J.@~~~~~~~ water vapor, particulates, biological aerosols, aDd othe~' contam- inants. Ga.rooJlcdieD4~1l~fha.$t,:~~~i4~~;mJd as..an..indigltor...()f:.~@~~.J~i;~~ijg~!~it~\~!"J1 PROC _ ~teria. 2 n ro e y any me 0 . tion, the effects of the possible elevation of other contam- \..... inants must be considered. . . In recent years a number of indoor contaminants have . .... received increased attention and emphasis. Some of these contaminants, such as formaldehyde or other vapor phase ,,orgaOO:^,CQnl~t!ate~,~a~~419Y JheJ1' . ,ts contents, and its site. Another important group of con- taminants is produced by unvented indoor combustion. The presence and use of consumer and hobby products, as well as cleaning and maintenance products, introduce a range of largely episodic releases of contaminants to the indoor environment (see Ref 30). There are also complex mixtures, such as environmen- tal tobacco smoke (see Ref 31), infectious and allergenic biologic aerosols, emanations from human bodies, and 77 a, Compute the air capacity per person in the space in fe (m3). b. Find the required ventilation rate, in cfm (Lis) per person. C. Enter Figure 4 with these values and read the maximum permissible venti- lation lag time after occupancy from the intersection of a and b. 100 50 ~ 50 25 z: 0 V) 0:= LLJ 10 5 z Q.. 0 "- V) ~ ~ w u a.. ....... VI 2.5 ........ 1 O. 1 5.0 0.5 10.0 , 0.5 1 .0 HOURS PERMISSIBLE LAG TIME Fig. 4 Maximum Permissible Ventilation Lag Time ASHRAE STANDARD 62-1989 @ Ktoil~ft GUIDELINES FORSELFhED'A~~~iAMtNANTs OF'INfioORORlm~'~.;~f Exposure Time Carbon Dioxide Chlordane Ozone Radon gas 1.8 g/m3 5 ILg/m3 100 p.g/m3 4 pCi/L (29. 32)b Continuous Continuous Continuous J\?Dual Average See Appendix 0 Reference 27 Reference 28 For existing houses that exceed 4 Ci/L see Ref 29 Comments aThis level is not .considered a health risk but is a surrogate for human comfort panCles. AE also recommends its use as a guideline for other building occu- todor), See Section 6.1.3 and Appendix D. pancies untilspecific recommendations for other occupancies are published byap- Th~ EPA recommendation app1ies specifICally to ....deotia1 and "",,001 oa:u- ,..priate authority. \ emanations from food preparation. Precise quantitative t acceptable technology, and vigilance regarding adverse { treatment of these contaminants can be difficult. To some i influences of reduced ventilation, must therefore suffice, ! degree, adequacy of control must rest upon subjective , Appendix C contains information on standards and guide- . evaluation. tlines for selected air contaminants. Uniform governmental I live :~~::oi~s:=~~::~::::~~~~:~~; l~=~~~:~::::~::;' a, Compute the air capacity per person in the space in fe (m)). b. Find the required ventilation rate. in cfrn (Lis) per person. c. Enter Figure 5 with these values and read the minimum required venti- lation lead time before occupancy from the intersection of a and b. 100 50 ~ z Vl 0 ex (/) LaJ 5 a:: Q.. w ........ a... ~ ...... Vl U ...... 2,5 1 0.1 5.0 0.5 1 .0 ~ HOURS REQUIRED LEAD TIME Fig. 5 Minimum Venti/ation Time Required Before Occupancy of Space (f) '1'& ':\'" ... OCT 11 '00 09: 28Arvl t'lUJ\lALCO t'lF'LS 612 92~' 0236 SPECIALTY SENSORS eX-! ,...,. P f\ i ',::",/' - ~ ('", .i U; , l\....~'~ _. '~.' 'I" ~ I .,~ CARBON DIOXIDE SENSORS MODEL4GS DESCRIPTION The Texas Instruments 4GS Series carbon dioxide sen~ sors a,.. dependable, economical devices designed to be used as inputs to building automation systems for effI- cient cOntrol Of ventilation. Using ambient C02 I."els to adju8t ventilation based on demand is recognized by ASHRAE as one of the few ways to comply with both thQ ventilation and en~rgy standards. The 4G8 Series pro. vides an analog output of C02 concentration from a smaU~ attractive wall mount package. An optional relay output Is avaUable for direct oontrol of equipment, and an opt;onai LCD display may be used for local indication, For duet appJioations, the 408 may be combined with an optional aspiration box. If the duct pr.ssu~ is positive or neutral and air velocity exceeds 200 ftlm;n (1.0 m/s), a Jess expensive impact sampling tube may be used. t FEATURES · An.1og output: 440 mA .,.".rd · F~/d ..lHtIIb. 0..10 VDC or tJ..6 VDC output -24 VAC",DCpower · "'YUf OIIllbtatlon IntervlIl · Opt/OM' "".Y (progl'llm",."" setpolnt) l"'i '."" I; ~~ \ ',II ,I:) .1ExAs INSTRUMENTS C€ · Optional LCD d~pl.y · No Initial olll/brat/on required -,Small, attfIJctlve wall ,"our" ."~'osu,.. · Option.' duct ..plr.tlon box or sampling tube kit 'RC,tACATlONI' " t . " .:1 , ~ ,\ . I . ".: I (Power' ~~. . I I I " , " I~V'W . 18-28 V AC 50/80 Hz or 18.40 VDC, less than 3 VA i i S.n8lng method I 1 Me..urlng fange NOIR - Non Dispersive Infrared 0..2000 ppm standard. field adjustable from 0-300 ppm to 0-5000 ppm ~75 ppm from 0 to 1500 ppm i:5% above 1500 ppm i Accuracy Pre..ur. eHect 0, , 9-/0 of reading per mm rig Re.,...bility =8 pprn Calibration inte",ar 3 years recommended Operating condition 92aF to 1220F (aOe to 5OQC) 5 to 960/0 RH, non condensing . '~ .', - . . ' , I Anal~g outP~t ..' . ,".' . '4.20'~~ into 500 ohm maximum I load (standard), field convertible I to ()"5 VDC or ().10 VDC with 1000 ohm output Impedance Optional relay Normally open, 10 mA to 500 mA at 24 VAC or 30 VDC t Field adjustable .etpoint 30a ppm I to 5000 ppm,1 00 ppm hysteresi8 I below 8etpoint I I Storage condition .40F to 158ClF (-20ClC to 700C) 5 to 950/. RH. non condensing Case ABS plastic, UL 94V.0 Weight Agencv approval 13 O~ (0,37 kg) FCC par115 Clas8 A, ce, @ , OCT 1 ~ ',00 ~9: 29~r.L 'M.INV,81.-.0~. f1PLS 612 '320 023 ..... ", ".. '. .. _~_.... :, ~".::," .' : '...;.." ~: 'j" ;,. " , , ", ' ' '. ," ' '\!", '. ; ,v,', ~.. ';l;!!~:"~ \ I'VI' ....', ':. (,.:.~~.~t . ~~ .'I!f')~' )r~r(~!.p . 4 t :, ': '1If-:I'''''/ j"~fJI:r~ J~~ ':i;",..:' "\,,' 't/"L~{.lfi~'~?,.(.),:~~' i~~;'I:'J~"~~~~/!:~, ':~~r."'.fr~., . .. · J~ 1'.a . '.\ ',";i', "I "\~i1.~ ~~ · ::;~it,p)'; "'~ ~~ ~..f .', _ 'IIC , .. .. 'J. h t OJ I "~ "..:. ""t~;f7. ~" ...tM~j;~';. ..," ' s '-. cc' , : -I .. I. f~ .~ I ,:;.( ~:'~ "":"~~:f: '~:!('./' '''';':',':+;, :",' . ~ ' .2 .' " \,~', ,':~~' 'ir,',',1 't~t~ "lO"'!":., "",' ~ ..J. '" ' & .', " II ,'.. I'J", ,,,..~,~~': ;..~.:' ." ':~~~"".~, '.' ,';.... '.P.' C u ' . ~ I" :: .';'1:" l'!'t~lll"J"~I'~ '."., .;',:' ",' '. '..' ':"',: ' s' " . : =. ~ t ' .')1 I J ". -0/: ";" ... ' " , , I i I .' )-''''.('18 itu;! ~~~.~:;,'. :.....' : t 1 'c . ::.II".J 111"IIJljjt':::' . ' . , i i . J '.'::;iti~1~;ill'lijlJ,;{:. i I u '.' " ." '. ',: IttitJ.f)~lfIHI"t~~fl: . :! i ! . ,,', iIi" ~1!:'lal.. I'I ~. u 8S ~ .~ . . JI .!ij!lfj.IJI~!f.i':' i i~ i! .1 ; 5. .lIJI.tn-"".jI1.,f ~ q !.' :)II'd.J~111 '.I'~ III .. . _ . j ~l' '!. .I',11l 'li,':!J'f'.t · ,li"I'~Jllf' ; . . ., i. i i ~J , a ! -I I. 1 ~ I .~' " . .! B ~... , ' , ',:,1J.,:~~". .' i.~~:: :,. '1' ", '., , : , . ,'''{>~.~'~'' , , . .. i 10 8 , 0 II. o ..i 0. If 8'.. ,~o ." ~ , I, ,.".......:...,""~.,:."., .,...'.~.' ~..,.,',. 'r':'.'........-..._,.;;.....;,'-;..' ...,I!..~..-::,,::..;'-",,~....- " . '~,' . .... ......'.'. ,_.-...~-,... '''__ , " et~r.t Uf' ':P)J~.' IJP .' i . I, hi: .' t~~11Jl!,tfi -J" :aJ-t 'J ~.~ J I" J ;a , ' 11 ~ J<< '" . j II - ,J~t"l f i J '1Jlj~ I,!~ I tl,!t~'1 ,Iff I'~"'J jf,i \ \ . :; . 'tS J! 'I". ., ~ . ~I -1.11 t I.!!.J I "IIJI!I ..II, A:'" ,'. \', ' ,,'.~\::\'" " '" ....... c: i - JC' :llt")) ';.' J1." !li"J : ."' [:",:.'""", ,'. .~.~':... "~'~t~<<:-{~~;,:r:,:..:':, ":'"..',.,':,., :,',' ;:jJl .'II,d'rl "'11,.. '.':'" \1' ,'. '... }'i,-';'.l..\'.: ""1 1'1' 1: i~!ijJ. f )11. . ~, II ..:"'i ',~:'.. .' .....:~~; ',: ,:':'-1 ; l,u A '~lj:.J I d~il dlh..'tt. '!. ~) .. Job Address . W-&t/CO Heating Contractor &:c~~ Name of Tester 7;.. !-17-C! -rt ~~ ~ /J/(; ?, Jl /~ .301 "p Date Percent 02 Percent CO Percent C02 Stack Temp, Combustion air is adequately supplied per UMC Sec. 606 ~ f ~ J Input (V. / .' i#\ Ge..~-~ya.....V) \~ae'\.. Sc,\I\~~~~t ,,~ "'~ % <:::) '- S.~ c.c"'- ,~- ~~""'-~~ ~ '- ~ a,::>~C "t",~~ '~"'~ '0 (::)' C) ~O \.00- ~~ Job Address ~~<bS\~~~~ ,.- \ Heating Contractor ~l:..,-~y~ I, I ~. . Name oflster ,~~~u.:-.. "'--~ rUlfIui ~ Date 301 ''-'-'-~'PO ~~~~~\A.... PimentO, ---,-'Q""~~.l~':"'_ ''\..\a'' " ~'-~\,~ \..\ Percent CO '-\.~~ ,~"'~\.~U ~ "'0 ~ ~ Percent C02 ~ - ~ 0/ '-- Stack Temp, ""- ~ '"" <:) ~. l. (::) L 0 Combustion air is adequately supp~ed per \ ~ "- ~~"'" <:... \0 UMC Sec, 606 Y e:. 0 <o~ ,-C ,~""'-~ Input \.,s) e " ~ ~ t) ~ t!:) (:) (:) -:s:-~~~~ ' - -.,.-: . ,c;o at a 0 a LJ!-, I I ,c;oCJ' ~~ <...:, <t:.. '-"."1:.....- ~ Y ~ t:, <t.. "" ""'t.. - ~ )"<A'v\. '\.<... -=> v.. \:S ~ '" ~'I ,"- ~ ~ \: Cl.::> '- "-,,,,~ '\:... <6. <>; b a ~ ~ ,~~'-c~ \..-~~~~(J ~a~ CCoo~~~'-t. ~~~~ _'" '" \. \-~~(J ~ '^--~~ ~ ~ '~~Q' C>O () '-. Q() ~ ~ \:- Job Address '-\.. ~~ ~ Q~(\.\l '-- ,~ , '-\... ~ Heatin9f~tpctor GOI\."t - ~ y ~"'- Name of T~ler ,~,:){~~ ~'""~~~\:... Date ,""','-,\ O() '" .....- Percent 01 '" a .._~ .. Percent CO2 S · \0 Percent CO " - ~~"^- Stack Temp, """-... '- ~ <:) ~"""~'-.)~. \o~\~~ Job Address "'~~ ~~ "'~)~ ~~)~ Heating Con';Jf.o~ '1.....- ~ 0.. <Uo. Name of Tester?o / ~ Date Percent Oa Percent CO Percent C02 Stack Temp, ,"'---''- '-...,~ ~O ~J~ ~O. <o._~ ~~ Cq.~ "' ~~,C Combustion air is adequately supplied per UMC Sec, 606 ye:..$ Input 'O~"bOO /1' I ~ ~ ~~ 419/ 0, If · ~ cc.. '-X:l.: ~ y~ '\\.~~~ ~~~, ,'-.,'-~""~~ <Q 0/ to (:) '-... ,,.'\.$0 '- ~ '- ,~~~~~C C) ~,~ %,~~ "'~~ ~""~~~ ,s~'~~ '~~'C)C)a " :: ,..~ % C) '- 'o5~o ,--0,"-- \<a -""-~O '-'-~" a ~"~~\.L T~~~ 't::~~~~ '\....... ~ ~" 0 a D ~\ 1J/rt, ~D~ Ov(:) '", STO AI~@ Twin City Testing Corporation TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 PROJECT NO: Nove~~~.9~~ I' i"') I ~ .f r:J r;:'J . ---',-' ,I... ". I ~" /1 ---. I j -~ ,'../ ) c- , . . ._" _ 03020",8., '.'...j ..S I, Ii; /'i,l Iii" NOV . Iii ',1 ~~,'~.I ~j 2 7 2000 . /./,/1,.,/1, ' , . 1:/..'1. ~ i_ I, i . t:Jy __ I, /;~ - ::::------ 1-City ofPrlO~-. --.:::;:- Attn: 1-Wensmann Homes Attn: Kelly Murray DATE: PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COpy TO: SOIL, REINFORCING STEEL (REBAR), CONCRETE, MASONRY TESTING AND OBSERVATION INTRODUCTION: This report presents the results of our observation and testing of the soil, rebar, concrete, and masonry for the Fountain Hills ShowroomlWarehouse project located in Prior Lake, Minnesota, Tom Sand of Wensco, Inc. authorized our work in the field on June 12, 2000. Our scope of services was limited to the following: 1, Observe the soils exposed within the mass excavation for the proposed building on an intermittent basis. 2. Perform shallow hand auger borings to aid in judging the localized subsurface soil conditions, 3. Judge whether the exposed soils are suitable for support of the anticipated fill and structural loads. 4. Perform intermittent compaction testing of fill soils placed to establish final grades. 5. Observe the reinforcing steel placement within the cast-in-place concrete footings and walls and to judge substantial compliance with the project specifications, 6. Perform intermittent testing of site structural concrete placements (i.e. footings, walls, etc.) for the building, 7. Perform intermittent sampling and compression testing of mortar (ASTM: C780) and grout (ASTM: C1 019) during masonry construction, 8. Observed the masonry construction work on an intermittent basis and verify substantial compliance with project plans and available specifications, Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used lor advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A ;.,IF) Twin City Testing Corporation F.:.........--_ No~em~erJ~,~.-"._. 2 "F Ii} '_~J (2) Lc' II :. V 1'/ I ! ! c,.') .r-:':;{ ", -, '. i 1) I r:'; 11 i . NO V -~ i 1/ CONCLUSIONS: I 2 7 2000 ' Ii J L/! I~~ j __ " B~sed on our o~s~rvations, hand auger b~rings, and field tests, it-~-.nm-np~ t~~___.! SOIls exposed wIthin the completed excavatIons for the proposed bUIldIng conslstea dt-=.~, sandy lean clays. The estimated strength or apparent density of the observed soils agreed, in our judgement, with that depicted by the pre-construction test borings performed for the project by Maxim Technologies, Therefore, these soils were judged suitable for support of the anticipated fill and foundation loading up to 2500 pounds per square foot (psf). 030238 DATE: PAGE: PROJECT NO.: The engineered fill placed to establish final grades was compacted to meet or exceed project specifications in all test areas. Prior to the contractor placing the concrete for the footings and foundation walls, we documented the number, size, spacing, length, and configuration of the reinforcing steel and other pertinent information to judge substantial compliance with the structural and shop drawings. During our observations, or at the completion of rebar placement, the areas observed were judged in general compliance with project specifications, The concrete placed for the footings and foundation walls met project specifications for compressive strength (ASTM: C39) in all test areas, The mortar and grout placed for the block wall construction met project specifications for compressive strength (ASTM: C39) in all test areas. PROJECT INFORMATION: The project site is located within the Fountain Hills Development just south west of the intersection of County Road 42 and Pike Lake Trail in Prior Lake, Minnesota. We understand the planned construction will consist of a two story slab on grade building with overall plan dimensions of 230' by 240'. The building will have a 29,300 square foot first floor with a 3,024 square foot second floor office area. Finished floor elevation for the building was shown on the plan as 100'. We further understand the footings will be placed to provide normal frost protection depth and were designed to exert a net allowable soil bearing pressure of 2500 pounds per square foot (pst), During our observations, we had access to the report of the pre-construction soil boring program performed at the site by Maxim Technologies (Maxim Project No. 9754408), The report indicated the generalized soil profile consisted of primarily natural clayey glacial till throughout the site. The topsoil depth ranged from Y2 foot in the area of the proposed building. The native clay till are very soft to firm in consistency, based on the penetration resistances (N values), Information and statements in this report are derived from material. information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STD AI~@ Twin City Testing Corporation f-~ Nofe.~6~~..'~1)Gl.P"~'-' 01 ,","L" ~r, L T7 I' 3 [ '\ '--, "~I il NOV 27 According to the report, site preparation should consist of rem~vlng the su~ag~ , vegetation, topsoil, and very soft clays from the building pad ars~s_lQ.__expose the;' competent soils. The underlying stiffer native clays should be sUitaETe"fof"bGttding.---! --",,,,"' footing support. Please refer to the referenced report for specific details. PROJECT NO.: 030238 DATE: PAGE: OBSERVATION METHODS AND RESULTS: Between June 2000 and September 2000, our firm observed the soils exposed during the excavation for Wensco's Fountain Hills Showroom\Warehouse, on an intermittent basis. In addition to observing the exposed soils, we placed several shallow (3~') hand auger borings into the subgrade at the bottom of the excavations. The observed soils and those retrieved by our shallow hand auger borings were visually and manually classified in general accordance with ASTM: 02488, and estimates were made of their strength properties, The excavations were performed with large bulldozers and backhoes, The excavation generally consisted of stripping the top ~' to l' of topsoil, removing the very soft clays from the proposed building areas and then placing engineered fill where necessary. The exposed soils, in the observed areas, were judged to consist of sandy lean clays with various amounts of gravel. The sandy lean clays were of soft to firm consistency and based on the resistance estimated by our hand auger probes. The observed soils appear suitable for support of the fill and structural loading, Based on off-set staking provided by the contractor at the time of our observations, the excavations, where applicable, appeared to extend a suitable distance beyond the building lines to provide satisfactory 1: 1 lateral oversizing. This oversizing is necessary for the lateral distribution of the foundation loads throughout the fill sequence. COMPACTION TESTING: Twenty-five (25) soil density tests were performed within compacted fill placed to establish the planned finish subgrades, on an intermittent basis. The density tests were evaluated according to the Moisture Density Relation of Soil as designated by ASTM: 0698-91 (Standard Proctor), The results of the tests, which are attached, indicated the recommended compaction level was attained or exceeded for the building pad, interior\exterior wall backfill, and the utility trenches. REINFORCING STEEL PLACEMENT: Prior to placing the concrete, we documented the number, size, spacing, length, and configuration of the reinforcing steel and other pertinent information to judge substantial compliance with the approved structural and shop drawings, As deficiencies were Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used lor advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of lalse, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law lltle 18. Chapter 47 STO RI~@ Twin City Testing Corporation PROJECT NO.: 030238 DATE: PAGE: November 22, 2000 4 ~ .. '"' --....-----.. ~'.,.._.~....._,.............. observed they were immediately brought to the attention of the ~eneralcbntr:ai~J~~ r~'I-l; and/or concrete subcontractor. .; . ,. III! ....Ii I NO V 2 7 2000 'j;) Durin~ our observati?ns. or a~ the co~pletio.n of reba~ yla?ement. tt"jt:i., C-a. r. e. a,.s o. bS. erved. L,. j were judged to be In compliance with project specifications. Tht3J2g~~I~n-~-..QtJb_~___._. j observed areas are documented on the attached reports titled Tests of-"Plasuc---..I Concrete. Due to the nature of reinforcing steel placement work, fluctuations of workmanship and quality may exist even with careful observations and review. The field review consisted of checks of workmanship quality and materials used. In our opinion, we performed our services in such a manner as to have reasonable confidence that the contractor's work, ongoing at the time of our visits, generally conforms to the project specifications. CONCRETE TESTING: Attached are plastic daily sheets documenting testing and sampling of plastic concrete. Our engineering technician performed tests for slump of the concrete mixture (ASTM: C231), air content of the concrete mixture (ASTM: C231) measured the temperature of the concrete, and cast the necessary concrete cylinders for the purpose of compressive strength testing. The results of our field-testing of plastic concrete are shown on the attached daily report forms, These reports also indicate the concrete mix design, the concrete supplier, the location of concrete placement, and the method of concrete placed. Concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compressive strength testing, The results of our compressive strength testing are also attached. As future compressive strength results become available, they will be forwarded separately. MASONRY TESTING: During the course of masonry construction, we periodically documented the number, size, spacing, length, and configuration of the reinforcing steel placed in block walls or beams, along with other pertinent information to judge substantial compliance with the referenced drawings, As deficiencies were observed, they were immediately brought to the attention of the contractor and corrected in the field. The individual results of compressive strength testing of the mortar and grout are attached to this report, The results show the compressive strength met the project specifications in the areas tested, Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A I.,@ Twin City Testing Corporation 030238 DATE: PAGE: I:"-'.~-. Nove~~r~,r ,)2600---,._., .. II'~ li~~r- I [~i f -- 5 ,f; .1>'./ L:J ~~ .! [' I,! ,t,_ <'" L..-._., '._, l PROJECT NO.: I REMARKS: .,.f NOV 2 7 2000 ! It must be recognize that we do not practice in the field of surveying, L%er.efGr~I,~e must rely on elevation and location information provided by others. If the construction fs redesigned or otherwise moved subsequent to our work, we should be informed so our firm can assess if additional engineering observation is required or suggest engineering alternatives. If you have any questions or if we can be of further service, please do not hesitate to contact us at (651) 645-3601. Very truly yours, ~JK TWIN Mtk ~traight Staff Engineer ~~~~ Leonard A. Rasmussen, P.E, Senior Geotechnical Engineer Attachments: 1-Building Footprint Sketch (1 page) 1-Density Tests of Compacted Fill #1-#25 (8 pages) 1-Moisture Density Curves #1-#2 (2 pages) 1-Daily Report of Masonry Inspection (3 pages) 1-Compression Tests of Mortar Cylinders Sets #1-#2 (2 pages) 1-Compression Tests of Grout Prisms Sets #1-#3 (3 pages) 1- Tests of Plastic Concrete (19 pages) 1-Compression Tests of Concrete Cylinders Sets #1-#19 (19 pages) Information and statements in this report are derived from material, information and/or specifications fumished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO AI~~I Twin City T~sting Corporation Fountain Hills ShowroomlWarehouse Pri~r ~a~~, Minr:tesota TeT #030238 11~22-00 w.... U I. r:-r :. u--:.- ,.-_... ..'--- , ~0 " , - '1.7 '. . 2 ' Q -0 i.,.'.- 85'.' '=(0 , , ' ,:-f ~,'. '6 ' . ;1,8.'. - G5--o {U . I~,_: LU .' C9 cD I .-rh , . ~ . -, 1M ~ I I r t. I I I I; . i .1 a 'I I I. ~- ......:....:._- -8, I 8 I I ,I- . ..:' G - .. (Sketch: Not to Scale) Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written.approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STORK@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA DATE: 662 Cromwell Avenue. St.I"Ea..~MN 55114-1776 (651) 645-3601. Fax (651 f65~frz~<-~.- "-.,~ ~>_''''~''~ l i ,--; I ;....J ..,....... July 5, 200cf PROJECT NO: 030238 i \ I C'J NOV 2 7 2000 COPY TO: 1-Wensmann Homes-- Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 1 2 3 4 DATE TAKEN: 6-29-00 6-29-00 6-29-00 6-29-00 UNIFIED SOIL CLASSIFICATION: Clayey sand with Clayey sand with Clayey sand with Clayey sand with (Moisture-Density Sample Number) a little gravel, a little gravel, a little gravel, a little gravel, mostly fine mostly fine mostly fine mostly fine grained, brown grained, brown grained, brown grained, brown {SC)-1 {SC)-1 {SC)-1 {SC)-1 LOCATION: Building pad Building pad Building pad Building pad backfill, backfill, backfill, backfill , Grid point C-3 Grid point D-5 Grid point B-2 Grid point D-8 DEPTH BELOW SUB GRADE: 6" 6" 6" 6" DEPTH BELOW EXISTING GRADE: 6" 6" 6" 6" FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 122 122,5 123 125 Moisture Content (%) 10,3 11,6 12,8 11.1 Plus #4 Material (%) 6 4 8 6 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pct) 123,9 123,9 Optimum Moisture (%) 11,1 11,1 COMPACTION TEST RESULTS: 123,9 11,1 123.9 11.1 Compaction Specified Compaction (%) (%) 98.5 98 99 98 99 98 101 98 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as to the adequ cy f fill and compaction at locations and elevations other than those tested, The test locations and n mb 0 tests re selected by Twin City Testing. TAKEN BY: REVIEWED BY: Q"7sIlo...l'1~ Ma Str ight Jay a son Staff Engineer Staff Engineer \\TWINCITIES NW5\SYS\BMC\2000CME\030238\D1-4.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47, STOR~@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA DATE: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601 Fax (6S1f659:7445^,=""""~~"--' . , :: ~, .,: '=: I ('~J j ~,' ::! \ t: : I.' . I ' ,'f~= II \ ' July 5, 2000/ .. ., NOV 2 7 2000 PROJECT NO: 030238 i I. I::. l. - -... "_ . .. COPY TO: 1-Wensmanrll-fomes'" Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 5 6 7 8 DATE TAKEN: 6-29-00 6-29-00 6-29-00 6-29-00 UNIFIED SOIL CLASSIFICATION: Clayey sand with Clayey sand with Clayey sand with Clayey sand with (Moisture-Density Sample Number) a little gravel, a little gravel, a little gravel, a little gravel, mostly fine mostly fine mostly fine mostly fine grained, brown grained, brown grained, brown grained, brown (SC)-1 (SC)-1 (SC)-1 (SC)-1 LOCATION: Building pad Building pad Building pad Building pad backfill, backfill, backfill, backfill, Grid point B-4,5 Grid point C-5 Grid point A.2-3 Grid point D-7 DEPTH BELOW SUB GRADE: 6" 6" 6" 6" DEPTH BELOW EXISTING GRADE: 3" 3" 3" 3" FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 124 122.5 122 124 Moisture Content (%) 9.7 13,1 11.2 10,1 Plus #4 Material (%) 4 4 4 4 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 123.9 123.9 Optimum Moisture (%) 11.1 11.1 COMPACTION TEST RESULTS: 123,9 11.1 123.9 11,1 Compaction Specified Compaction (%) (%) 100 98 99 98 98,5 98 100 98 REMARKS: Density tests are valid at the location and elevation of the test only, No representation is made as to the adequacy of fill and compaction at locations and elevations other than th se tested. The test locations and number of tests were selected by Twin City Testing. TAKEN BY: Q7~ REVIEWED BY: Jay H nson Staff Engineer F:\BMC\2000CME\030238\D5-8.doc Information and statements in this report are derived from material. information and/or specifications fumished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full. without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47, STOAI~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA DATE: July 1 0, 2~qq i: ~ ! NOV 2 7 2000 PROJECT NO: 030238 COpy TO: / J 1-Wensn)ar;m ..tf.ornes Attn: TorrfSan"(j::; 1-City of Prior Lake Attn: Susan McDermott TEST NUMBER: DATE TAKEN: DENSITY TESTS OF COMPACTED FILL 9 10 7-7-00 7-7-00 UNIFIED SOIL CLASSIFICATION: (Moisture-Density Sample Number) Sandy lean clay with a little gravel, brown (SC)-2 Sandy lean clay with a little gravel, brown (SC)-2 LOCATION: Water main, backfill, 45'W of MH2 Water main, backfill, 30'S & 90'W of MH2 DEPTH BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 5' 4' 6" 6" Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 113 110,5 Moisture Content (%) 12,9 9,8 Plus #4 Material (%) 6 4 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91. Procedure "A". (-#4 Basis) Maximum Dry Density (pet) 113,7 113,7 Optimum Moisture (%) 14,2 14.2 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 99.5 95 97 95 TAKEN BY: Density tests are valid at the location and elevation of the test only. No representation is made as to the a y of fill and compaction at locations and elevations other than those tested. The test locations and r of tes were selected by Twin City Testing, REVIEWED BY: Q7 ~ Jay anson Staff Engineer REMARKS: Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47, STOR~@ Twin City Testing Corporation 662 Cromwell Avenue, st. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE COpy TO: PRIOR LAKE, MINNESOTA DATE: July 10, 2000 i I i Iii , 'I PROJECT NO: 030238 NOV 2 7 2000 1-WensmanniHomes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 11 12 DATE TAKEN: UNIFIED SOIL CLASSIFICATION: (Moisture-Density Sample Number) 7-8-00 7 -8-00 13 7-8-00 DEPTH BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Clayey sand with Clayey sand with Clayey sand with a little gravel, a little gravel, a little gravel, mostly fine mostly fine mostly fine grained, brown grained, brown grained, brown (SC)-1 (SC)-1 (SC)-1 Sanitary sewer, Sanitary sewer, Water main, 50'E of MH2 6'S of MH2 120W of MH2 3' 3' 3' 3' 3' 3' LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 119 125 118 Moisture Content (%) 7.8 9,7 5,6 Plus #4 Material (%) 8 10 9 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "An, (-#4 Basis) Maximum Dry Density (pet) 123.9 123.9 Optimum Moisture (%) 11,1 11.1 COMPACTION TEST RESULTS: 123,9 11.1 Compaction Specified Compaction (%) (%) 96 95 101 95 95 95 TAKEN BY: Density tests are valid at the location and elevation of the test only. No re resentation is made as to the adequacy of fill and compaction at locations and elevations other than th e sted. The test locations and number of tests wer elected by Twin City Testing. L REVIEWED BY: REMARKS: oward Peterson enior Engineering Assistant F:\BMC\2000CME\030238\D11-13.doc Information and statements in this report are derived from material, information andlor specifICations furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47, STOR~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE COPY TO: PRIOR LAKE, MINNESOTA DATE: July 31, 2000 ! I \ ,:; I I \ ~ I L! Li PROJECT NO: 030238 NOV 2 7 2000 1-Wensm~nn Homes Attn: TOffl-'sana:.:::-.' - '~,,_::_:;~:='.:=.::::-,:~..:'~::.... 1-City of Prior Lake AUn: Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 14 15 16 17 DATE TAKEN: 7-27-00 7-27-00 7-27-00 7-27-00 UNIFIED SOIL CLASSIFICATION: Sandy lean clay Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little with a little gravel, brown gravel, brown gravel, brown gravel, brown (CL)-2 (CL)-2 (CL)-2 (CL)-2 LOCATION: Interior backfill, Interior backfill, Interior backfill, Interior backfill, Grid A.1, 1.5 Grid 8.4, 5.9 Grid C.1, 6.9 Grid D.1, 7.5 DEPTH BELOW SUBGRADE: 98' 96~' 96~' 97' DEPTH BELOW EXISTING GRADE: 3" 3" 3" 3" FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 111.5 112 109.5 114 Moisture Content (%) 11.4 11.6 13,7 9.9 Plus #4 Material (%) 4 4 2 2 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pct) 113.7 113.7 Optimum Moisture (%) 14.2 14.2 COMPACTION TEST RESULTS: 113,7 14.2 113.7 14.2 Compaction Specified Compaction (%) (%) 98 95 98,5 95 96.5 95 100.5 95 REMARKS: Density tests are valid at the location and elevation of the test only. No represent ion is made as to the adequacy of fill and compaction at locations and elevations other than th e teste . The test locations and number of tests were selected by Twin City Testing. TAKEN BY: Q~ !.kt<~ REVIEWED BY: Jay Ha son - Staff Engineer F:\BMC\2000CME\030238\D14-17.doc Information and statements in this report are derived from material, infonnation and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47, STClR~@ Twin City Testing Corporation 662 Cromwell Avenu~,.St. Paul,MN 55114-1776 (651) 645-3601 r Fax (651) 659-7348 ,.. _. TO: PROJECT: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA DATE: August 14,2000 NOV 2 7 2000 PROJECT NO: 030238 COpy TO: 1-wensriii:mn'dH'omes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 18 19 20 21 DATE TAKEN: 8-9-00 8-9-00 8-9-00 8-9-00 UNIFIED SOIL CLASSIFICATION: Sandy lean clay Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a Iittl e with a little with a little with a little gravel, brown gravel, brown gravel, brown gravel, brown (CL)-2 (CL)-2 (CL)-2 (CL)-2 LOCATION: Exterior wall Exterior wall Exterior wall Exterior wall backfill, Grid backfill, Grid A.5, backfill, Grid A.1, backfill, Grid B,3, C.5,2.9 1 4.9 6.1 DEPTH BELOW SUBGRADE: 99' 99' 99' 96' DEPTH BELOW EXISTING GRADE: 3" 3" 3" 3" FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 111 110,5 111 110 Moisture Content (%) 10.8 11.6 12.1 13.0 Plus #4 Material (%) 6 4 8 6 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.7 113,7 Optimum Moisture (%) 14.2 14.2 COMPACTION TEST RESULTS: 113.7 14.2 113.7 14,2 Compaction Specified Compaction (%) (%) 97.5 95 97 95 97,5 95 96.5 95 REMARKS: Density tests are valid at the location and elevation of the test only, No representation is made as to the adequacy of fill and compaction at locations and elevations other than t 0 teste. The test locations and number of tests were selected by Twin City Testing. TAKEN BY: ~/~-27 ~ REVIEWED BY: '" Jay Hanson Staff Engineer F:\BMC\2000CME\030238\D18-21.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47, STOA~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (6S.1)J?~.~::?3~4:8,._ PROJECT NO: August 1~,?QOO"j ,- NOV 2 7 2000 030238 TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA DATE: COpy TO: \ : / 1-WenSrlmlln:Hames; Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TEST NUMBER: DATE TAKEN: DENSITY TESTS OF COMPACTED FILL 22 8-9-00 UNIFIED SOIL CLASSIFICATION: (Moisture-Density Sample Number) Sandy lean clay with a little gravel, brown (CL)-2 LOCATION: Exterior wall backfill, Grid E.1, 4,5 DEPTH BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 99' 3" Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pct) 110 Moisture Content (%) 12.3 Plus #4 Material (%) 6 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.7 Optimum Moisture (%) 14.2 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 96.5 95 REMARKS: Density tests are valid at the location and elevation of the test only. No r presentation is made as to the adequacy of fill and compaction at locations and elevations other t n th s tested. The test locations and number of tests were selected by Twin City Testing, TAKEN BY: L~7 ~UV-'^-_____ REVIEWED BY: Jay Ha so. Staff Engineer F:\8MC\2000CME\030238\D22.doc Information and statements in this report are derived from material, information and/or specifications fumished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47. STOR~@ Twin City Testing Corporation 662 Cromwell Avenue, StPaull:MN~5Jl4-:1 776 (651) 645-3601, Fax (651) 659-,13Mt . ".,-"...........IIl.>....,....! TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: PROJECT NO: PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPY TO: 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott DEPTH BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: DENSITY TESTS OF COMPACTED FILL 23 24 25 8-11-00 8-11-00 8-11-00 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown gravel, brown gravel, brown (CL)-2 (CL)-2 (CL)-2 Interior wall Interior wall Interior wall backfill, Grid backfill, Grid backfill, Grid A,1, C.5,3,1 D,9, 7,3 1.5 99' 99' 99' 3" 3" 3" TEST NUMBER: DATE TAKEN: UNIFIED SOIL CLASSIFICATION: (Moisture-Density Sample Number) LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 113 109.5 108 Moisture Content (%) 8.1 12.7 14.6 Plus #4 Material (%) 4 6 8 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.7 113.7 Optimum Moisture (%) 14.2 14.2 COMPACTION TEST RESULTS: 113.7 14,2 Compaction Specified Compaction (%) (%) 99.5 95 96,5 95 95 95 REMARKS: Density tests are valid at the location and elevation of the test only. No repr sentation is made as to the adequacy of fill and compaction at locations and elevations other than those, ested, The test locations and number of tests were selected by Twin City Testing. . TAKEN BY: c.:-7'70 ~-- REVIEWED BY: Jay Ran on Staff Engineer F:\BMC\2000CME\030238\D23-25.doc Information and statements in this report are derived from material, information and/or specifications fumished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statues including Federal Law Title 18, Chapter 47, STOAK@ Twin City Testing Corporation 662 Cromwell Avenue, st. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA METHOD OF TEST: ASTM:D698-91 Procedure A SAMPLE NO: TYPE MATERIAL: Clayey sand, mostly fine grained, brown (SC) MAXIMUM DENSITY (pet): 123.9 OPTIMUM MOISTURE (%): 11,1 122 .-IP" :- '" i..... ,.- i'" 1/ "- ". ,''' " I" " l"- I\. 1/ j 1'\ I' I\. \. \. \. \ , " \ 10 11 12 Moisture Content, % 13 14 126 125 124 It- U Q. ~ ... 'ii) c cu C ~ 123 C 121 120 9 STORK@ Twin City Testing Corporation 662 Cromwell Avenue, st. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-~~~~';-~""7"-'-- ", .,. I,,; I DATE: July HJ;~OOO PROJECT NO: 03023tj,j NOV 2 7 2000 TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA METHOD OF TEST: ASTM:D698-91 Procedure A SAMPLE NO: 2 TYPE MATERIAL: Sandy lean clay, brown (SC) MAXIMUM DENSITY (pet): 113.7 116 OPTIMUM MOISTURE (%): 14.2 111 , ... ~.,,- ..... , ...... ,~ ~ ...... !..; ...... ..; I'.. ..; " I'\: '- 1/ I\. J " / " \. I I \ I\. \ I\. , I\. 13 14 15 Moisture Content, % 16 17 115 114 """ u Co >; - 'en c CI) C ~ 113 c 112 110 12 STO AI~@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMNVAREHOUSE PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348,,," DATE: July 28, 2090 PROJECT NO.: 030238 . -...-....~ f I Ii ) j t ':'" NOV 2 7 2000 COPY TO: 1- Wensman-n-'Romes~~.. ~':. Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott DAILY REPORT OF MASONRY INSPECTION DATE: TI ME: WEATHER: INSPECTOR: LOCATION: GROUTING: STORAGE OF MATERIALS: MATERIAL PROPORTIONING: 1) Mortar 2) Grout LAYING: 1) Bed Joint 2) Head Joint REINFORCEMENT: 1) Spacing, Size, Splices 7-27 -00 1:30pm Sunny,820F Jay Hanson 8", 12" & 16" below grade block wall, running bond pattern, Grid lines (A-C, 1-3), Elevation 97'-0" to 99'_4" Bond beam, Grid lines (A-C, 1-3) On pallets, covered Type S, Spec Mix #1455 3498 (3000 psi strength) 3/8" to 5/8" 3/8" to 5/8" As per Douglas R, Iverson, P,A. Structural Engineering, Sheets S1 to S9, Revised 5-30-00 GENERAL OBSERVATIONS: 1) Cast 3%lIx3%lIx7" grout prisms set #1 (A-C) for compressive strength tests. 2) Cast 311x6" mortar cylinders set #1 (A-C) for compressive strength tests. 3) Asked masonry foreman to cast 3-8" block prisms for compressive stren th tests. INSPECTED BY: q ~ REVIEWED BY: . Jay anson Staff Engineer F:\BMC\FORMS\MASONRY INSPECTION.doc -,......- Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STCJ R I~@ Twin City Testing Corporation PROJECT: Kelly Murray' Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS SHOWROOM/WAREHOUSE PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (65)l.6.~~_: 7348 ir--' . ....~":'-. -.-..,.'---.'--~, DATE: ~: ~August 15" ~OOO!.: .r r I '- ' !. ! \'j L~:.;; PROJECT NO: ~... ;:'030238 i I ~.: i .N~V 2 7 2000 i !i _ L_, i !.... /1_-_xy~~smann. ~_~m... es];! -- ---'Attn:-Tom sand::::::.::: 1-City of Prior Lake Attn: Susan McDermott COPIES TO: TO: CAlLY REPORT OF MASONRY INSPECTION DATE: TI ME: WEATHER: INSPECTOR: LOCATION: 8-7 -00 11 :30am Sunny, 750F Jay Hanson r....' , GROUTING: STORAGE OF MATERIAL: MATERIAL PROPORTIONING: 1) Mortar 2) Grout 8" above grade block wall, Running bond pattern Grid lines B-C, 6-7 Elevation 100'-0" to 1 04'-0" N/A On pallets, covered, Type 5, Spec mix #1455 N/A LAYING: 1) Bed Joint 2) Head Joint REINFORCEMENT: 1) Spacing, Size, Splices 3/8" to 5/8" 3/8" to 5/8" As per Douglas R, Iverson, P,A., Structural Engineering Plan, Sheets 51-59, REV 5/30100 GENERAL OBSERVATIONS/REMARKS: 1. Cast mortar set #2(A-C) for compressive strength tests, 2. Asked masonry foreman to construct 3-8" block prisms, 3 courses high, for compression tests. 3. Observed IDur-Q-Wal' every other course, TESTED BY: <4-7 ~ Jay Hanson Staff Engineer \\TWINCITIES _NW5\SYS\BMC\2000CME\030238\MASONRY INS ,doc REVIEWED BY: Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~@ Twin City Testing Corporation PROJECT: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS SHOWROOM/WAREHOUSE PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348', i> ",. , ii', i.,"', i I DATE: Sept~mber 6; 2000 PROJECT NO: 030238 NOV 2 7 2000 I Ii , L~I 1- wktma!lIT~:cc.c.c.:.-:cJ Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TO: COPIES TO: CAlLY REPORT OF MASONRY INSPECTION CA TE: TIME: WEATHER: INSPECTOR: LOCATION: 8-30-00 11 :OOam Partly Cloudy, 720F Jay Hanson 8" above grade block wall, Running bond pattern Grid lines 8, 2-4,5 Elevation 120'-0" to 124'.011 Spec, Mix #4768 On pallets, covered. GROUTING: STORAGE OF MATERIAL: MATERIAL PROPORTIONING: 1) Mortar 2) Grout Type S, Spec mix #1455 Spec. Mix #4768 LAYING: 1) Bed Joint 2) Head Joint REINFORCEMENT: 1) Spacing, Size, Splices 3/8" to 5/8" 3/8" to 5/8" As per Douglas R, Iverson, P,A., Structural Engineering Print Dated 5-30-00 GENERAL OBSERVATIONS/REMARKS: 1. Cast grout set #3(A-C) for compressive strength tests, 2. Asked masonry foreman to construct 3 block prisms, 3 courses high, for compression tests, 3, All erected masonry walls were adequately braced at the time of inspection, TESTEDBY~ ~. Jay H nson Staff Engineer \\ TWINCITIES _NW5\SYS\BMC\2000CME\030238\MASONRY INS2,doc REVIEWED BY: Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I..,<J) TO: Twin City Testing Corporation ~:':".'- . ... . _..-. 662 Cromwell Avenue, St. Paul, MN 55114~1tiB ! i (651) 645-3601, Fax: (651) 659-7348 LJ DATE: October 4, 200~OV 2 7 2000 Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA PROJECT NO.: 030238 i COPY TO: 1-Wensmann Homes AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott COMPRESSION TESTS OF MORTAR CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Type of Sample: Location of Placement: Specified Stre ngth, psi: Mix Designation: Mix Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Area Tested, sq, in,: Load at Failure, Ib,: Compressive Strength, psi: 1A 18 7-27-00 7-27-00 7 28 3"xa" mortar cylinder 12" Block wall, Grid lines (E, 7-8), Elevation 100'-0" to 104'-0" 1800 Type S Spec mix #1455 J, Hanson 1C 7-27-00 56 ASTM:C780, "Standard Test Method for Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry" 010654-A 8-1-00 5 2 8-3-00 9:50am 7,07 7290 1030 010654-8 8-1-00 5 23 8-24-00 2:25pm 7,07 11510 1630 010654-C 8-1-00 5 51 9-21-00 11 :OOam 7.07 12870 1820 REMARKS: The 56-day compression test results meet the specified strength, g~{~~ ~- Jay an. on Staff Eng ineer \\TWINCITIES_NW5\SYS\BMC\2000cME\030238\010654 (mortar) .doc N A\ ~/ ~~s\raN Staff Engineer Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STORI~(!?) Twin City Testing Corporation TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COPY TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA September, 27, 200<) j I 030238 NOV 2 7 2000 1-Wensmam(~.. Attn: Tom Sand "'. 1-City of Prior Lake AUn: Susan McDennott COMPRESSION TESTS OF MORTAR CYLINDERS FIELD DATA: Job Identification: Date Cast Age to be Tested, days: Type of Sample: Location of Placement: Specified Strength, psi: Mix Designation: Mix Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Area Tested, sq, in.: Load at Failure, Ib,: Compressive Strength, psi: REMARKS: 2A 28 8-7-00 8-7-00 7 28 3"x6" mortar cylinder 8" Block wall, Grid lines (C, 6-7), Elevation 100'-0" to 104'-0" 1800 Type S Spec mix #1455 J, Hanson 2C 8-7-00 Hold ASTM:C780, "Standard Test Method for Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry" 010713-A 8-9-00 2 5 8-14-00 10:00am 7,07 9400 1330 010713-B 8-9-00 2 26 9-4-00 4:45pm 7,07 15500 2190 010713-C 8-9-00 2 Hold The 28-day compression test results meet the specified strength, ~~~. Jay an on Staff Engineer \\lWINCITIES_NW5\SYS\BMC\2000cME\030238\010713 (mortar).doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STOAI~@ Twin City Testing Corporation 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) i6$~:~j-'.'~'.P.- I: I /; .I l-'::J '\.~I i TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COPY TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA Augosti24.2000 i :! NO V 2 7 2000 030238 r r ,., I' ' j -'- -". .~. ,--.:, ... ..... -.-. j 1-Wensmann H()'mes~:,::.:'.:::::.-J AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott COMPRESSION TESTS OF GROUT PRISMS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Type of Sample: Slump (ASTM:C143), in.: Location of Placement: Specified Strength, psi: Mix Designation: Mix Furnished By: Prisms Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Area Tested, sq, in.: Type of Fracture: Load at Failure, Ib,: Compressive Strength, psi: 1A 18 7 -27 -00 7-27 -00 7 28 3~" x 3~" Nominal Grout Prism 8 Bond beam, Grid lines (A-C, 1-3), Elevation 99'.4" 3000 3498 Cemstone J. Hanson 1C 7 -27 -00 Hold ASTM:C1 019, "Standard Test Method for Sampling and Testing Grout" 010655-A 8-1-00 5 2 8-3-00 9:55am 12.50 Shear 28060 2240 010655-8 8-1-00 5 23 8-24-00 2:40pm 11,39 Shear 40750 3580 010655-C 8-1-00 5 Hold REMARKS: The 28-day compression test results meet the specified strength, l17so~ Staff Engineer \\TWINCITIES_NW5\SYS\BMC\2000CME\030238\010655 (grout) .doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I..,(I~) Twin City Testing Corporation TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COPY TO: SHOWROOM/WAREHOUSE PRIOR LAKE, MINNESOTA September '27', 20(10 : NO V 2 7 2000 030238 1-Wensmarfn'Homes Altn: Tom Sand 1-City of Prior Lake Attn: Susan McDennott FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Type of Sample: Slump (ASTM:C143), in,: Location of Placement: . Specified Strength, psi: Mix Designation: Mix Furnished By: Prisms Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number. Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Area Tested, sq, in,: Type of Fracture: Load at Failure, Ib,: Compressive Strength, psi: COMPRESSION TESTS OF GROUT PRISMS 2A 28 8-9-00 8-9-00 7 28 3%" x 3%" Nominal Grout Prism 8 Block wall core fill, Grid lines (0, 3-4), Elevation 104'-0" to 108'-0" 3000 4768 Spec Mix J, Hanson 2C 8-9-00 Hold ASTM:C1 019, "Standard Test Method for Sampling and Testing Grout" 010723-A 8-11-00 2 5 8-16-00 10:27am 11,73 Shear 31150 2660 010723-B 8-11-00 2 26 9-6-00 9:50am 12,25 Shear 41900 3420 010723-C 8-11-00 2 Hold REMARKS: The 28-day compression test results meet the specified strength, Gn Staff Engineer ~W~ M ~traight Staff Engineer \\TWINCITIES _NW5\SYS\BMC\2000cME\030238\010723 (grout).doc Information and statements in this report are derived from material, information and/or specifications fumished by the client and exclude any expressed or implied warranties as to ttle fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on ttlis document may be punished as a felony under Federal Statutes including Federal Law Title 18. Chapter 47 STORI~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-73,~& October 3q, ~pOO TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA 030238 NOV 2 7 2000 e j I I 1-WensmanriHomes._ Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF GROUT PRISMS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Type of Sample: Slump (ASTM:C143), in,: Location of Placement: Specified Strength, psi: Mix Designation: Mix Furnished By: Prisms Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Area Tested, sq. in,: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 3C 8-30-00 Hold 3A 3B 8-30-00 8-30-00 7 28 3~" x 3~" Nominal Grout Prism 8 Bond beam, Grid lines B, 2-4.5, Elevation 124'0" 3000 4768 Spec Mix J, Hanson ASTM:C1 019, "Standard Test Method for Sampling and Testing Grout" 010859-A 9-1-00 2 5 9-6-00 10:10am 12,25 Shear 33930 2770 010859-B 9-1-00 2 26 9-27-00 11 :05am 10,56 Shear 51460 4870 010859-C 9-1-00 2 Hold REMARKS: The 28-day compression test results meet the specified strength, 07Jk~ Jay Ranson Staff Engineer F:\BMC\2000CME\030238\010859 (grout).doc Information and statements in this report are derived from material, information and/or specifications fumished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STOAI~@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: July 10, 2Q90 I" ..., PROJECT NO: PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 030238; , NO V !~ 2 7 2000 1-Wen~mann Homes AttnttOItt~and .... .-.-.- 1-City o(PriorL.ak-e: , co. - Attn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number B772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-7-00 3067HM Cemstone Strip footing, Grid lines (D-E, 8), (E, 4-8), (D,7-E, 4) Truck discharge 9 Cloudy 750F T, Newhall Th f II rf d h k d e 0 oWing tests were pe orme at t e truc ,exce pt as note : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Corrvnents Tests Number (in,) (%) Temp, (OF) Cast Added (gal,) Added (gal,) 12:45pm 278 3 1.8 75 1 (A-D) - - Project Specs, Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compression test results will be t0r~~~:l:el~ a . hey become available. ~ A ld Tyler Newall Mark" Straight ~ Engineering Technician Staff Engineer F"SMC'1000CME'O?(I:nR'P1 ':l",:, Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Trtle 18, Chapter 47 STO RI~@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7~~8.;__,_ DATE: July 18, 200;OL.: PROJECT NO: 030238 I NO V 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensm~~omes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 8772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: 7-11-00 3067LM Cemstone Strip footing including column pads, Grid lines (C,8-D, 8), (0, 7-8), (C,8, 7,2-8) Truck discharge 6,5 Partly Cloudy 800F T, Newhall Method of Placement: Total Yards Observed: Weather: Field Technician: The following tests were performed at the truck, except as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in.) (%) Temp. (OF) Cast Added (gal,) Added (gal.) 1 : 15pm 141 4 1.5 83 2(A-D) - - Project Specs, Min. - N/A 55-90 Max. 4 A1 .. laboratory for m. oist curing and compression testing. feR ed pa )ely, as they become available, .,? 1AJ/ .' , Tyler Newhall Engineering Technician F:\BMC\2000CME\030238\P2,doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STORI~@ Twin City Testing Corporation TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA July 17, 2000 NOV 2 7 2000 PROJECT NO: 030238 COPIES TO: ~-. : .---.-- 1-Wensmann ''Homes AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number B772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; e 0 owmg tests were pe orme at t e true , exce )t as note : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) (%) Temp. (oF) Cast Added (gal,) Added (gal,) 1 :30pm 535 3% 1.7 87 3(A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: Th f II 7-13-00 3067LM Cemstone Strip footing including column pads, Grid lines (C,8, 7-7,2), (B,8-C,8, 7), (C, 6-7), (B,8, 6-7), (B-C, 6), (B, 5,7-6) Truck discharge 8,0 Sunny, gOoF T, Newhall rf d h k d REMARKS: The concrete test cylinders were temporarily stored at the project'and then submitted to our laboratory for moist curing and compression testing, Com res i n test Ii suits will be ~efo~. ed sepa ately as they become available, 1/V,en I Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\P3.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A I.,@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348. DATE: July 17, ~OO,Q NOV 2 7 2000 PROJECT NO: 030238 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-WensmahifROmes: Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number B772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-14-00 3067LM Cemstone Strip footing, Grid lines (8, 4,2-6), (A,1, 4,5-5), (A-8, 5), (A-8, 4,5) Truck discharge 6,5 Sunny,90oF T, Newhall Th f II t rf d h k d e 0 OWing tes s were pe orme at t e true , exce pt as note : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Convnents Tests Number (in,) (%) Temp, (oF) Cast Added (gal.) Added (gal,) 1 :45pm 471 2% 1.8 85 4(A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A I..,@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348. DATE: July 18, 2qOO PROJECT NO: 030238 i I NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1- WensrrfartFrt10mes_ AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 411); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-17-00 3067LM Cemstone Strip footing including column pads, Grid lines (D-D.7, 4), (D, 3-4) Truck discharge 8 Sunny,BOoF T, Newhall Th f II d h k d e 0 oWing tests were performe at t e truc ,exce)t as note : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in.) (%) Temp. (OF) Cast Added (gal.) Added (gal.) 1 :45pm 263 5 1.5 78 5{A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compressi n test results will be reported separately, as they become available, Jim Gresser f resse Concrete/Masonry was info me the high slump of the concrete, W'~ Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\P5,doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I.,@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN55tt4.:1776 (651) 645-3601, Fax: (651) 659-7348' . ~" TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: t July 21, 2000 NOV 2 7 2000 .. I ',.1 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott PROJECT NO: 030238 TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 3483); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-18-00 3067LM Cemstone Strip footing, Grid lines (A, 2-4,2) Truck discharge 10 Cloudy,50oF T, Newhall T he following tests were performed at the truck, exce:>t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in.) (%) Temp. (OF) Cast Added (gal.) Added (gal,) 1 :45pm 123 4 1,5 70 6(A-D) - - Project Specs. Min, - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the projec and then submitted to our laboratory for moist curing and compression testing, Compre i n test results will be ~ reporte9 se~ara ely, as they become available, /77.f tU:l1 r Tyler Ne hall Engineering Technician F:\BMC\2000CME\030238\P6.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal law Title 18, Chapter 47 STORI~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: July 21, 20~()O:'~-''''''', Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 TO: .' I L! COPIES TO: NQV 2 7 2000 1-Wen~ma_rl_n Homes AUn: Tom.sana 1-City of Prior Lake AUn: Susan McDermott PROJECT NO: 030238 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 411); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: Th f II 7-19-00 3067LM Cemstone Strip footing, Grid lines (A, 1-2), (A-A,8, 1) Truck discharge 9 Sunny, 700F T, Newhall e 0 owina tests were performed at the truck, exce)t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) (%) Temp. (OF) Cast Added (gal.) Added (gal,) 1 :45pm 125 3% 1.5 75 7(A-O) - - Project Specs. Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing, Com res 019 test results will b reported se af, Iy, as they become available. 1;V/~ Tyler N hall Engineering Technician F:\BMC\2000CME\030238\P7.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO AI~@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-t~48~' DATE: July 25,'2000 " NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmann Homes AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott PROJECT NO: 030238; TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 . Sampling Freshly Mixed Concrete; ASTM:C143 . Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 411); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-20-00 3067LM Cemstone Strip footing, Grid lines (B, 1,7-2), (B-C, 2) Truck discharge 10 Sunny, 750F T, Newhall II rf d d The fo owing tests were pe orme at the truck, exce pt as note : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Corrvnents Tests Number (in,) (%) Temp. (OF) Cast Added (gal,) Added (gal,) 1 :45pm 152 4 1.7 76 8(A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Trtle 18, Chapter 47 STO R I..,@ Twin City Testing Corporation Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: July 25,2000' PROJECT NO: 030238 NO V 2 7 2000 COPIES TO: I 1-We~smann Homes Attn: 10m 'Sand- 1-City of Prior Lake Attn: Susan McDermott PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 411); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; e 0 OWInQ es s were pe orme a e true ,exce >t as note : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Convnents Tests Number (in.) (Ofo) Temp, (oF) Cast Added (gal,) Added (gal.) 2: 1 Opm 521 3% 1.5 79 9(A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: Th f II t t 7-20-00 4067LM Cemstone Foundation wall, Grid lines (C.8-D, 8), (C,8, 7-8) Truck discharge 10 Sunny, 750F T, Newhall rf d t th d k REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing, Compressi test results will be ../1. ~~rt~. separatel as ey become available, / ~L ~ J ;LIlli/I? V ,,~ / Tyler Ne hall Engineering Technician F:\BMC\2000CME\030238\P9.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I..,@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: July 25, 2000 PROJECT NO: 030238 NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wens"1ann: Hom~s AUn: Tom saner""'.- 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 411); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-21-00 3067LM Cemstone Strip footing, Grid lines (C.8-D, 3), (B, 1-1,7), (A,8-B, 1), (e, 2-2,3) Truck discharge 10 Sunny, 750F T, Newhall Th f II t t rf d t th t k t t d e 0 owma es s were pe orme a e ruc , exce )1 as no e : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) ('!o) Temp. (oF) Cast Added (gal,) Added (gal,) 1 :45pm 153 5% 1.5 n 10(A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compression st results will be reported separately, as they become available, Pete Lars n of re ser Co rete/Masonry "Ejf !nfOrme 'II the high slump of the concrete, 111) ,. f ~~;f Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\P1 Q,doc Information and statements in this report are derived from material. information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18. Chapter 47 STCJ R I....,@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348- DATE: July 25, 2000 PROJECT NO: 030238 NQV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensma'iuf Homes AUn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 8772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-24-00 3067LM Cemstone Strip footing including column pads, Grid lines (8, 4-4,5), (C-C,8, 3) Truck discharge 10 Sunny,80oF T, Newhall The following tests were performed at the truck, exce )t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Convnents Tests Number (in.) (%) Temp, (oF) Cast Added (gal,) Added (gal,) 1 :45pm 278 6% 1.5 80 11 (A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compression test results will be reported separately, as they become available, Pete Larson of r, sser ncrete/M~sonry was inf rme of he high slump of the concrete, ~~, Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\P11.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R ,.,,@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: July 25, 2000' PROJECT NO: 030238 NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: \ 1-Wens",an,n Homes AUn: T()mSandu,'.. _ 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 8772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7-24-00 4067LM Cemstone Column piers, Grid points (D, 7), (C, 6) Truck discharge 10 Sunny, 800F T, Newhall Th f II e 0 owma tests were performed at the truck, exce )t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Convnents Tests Number (in.) (%) Temp, (OF) Cast Added (gal.) Added (gal.) 2:10pm 471 4 1.5 79 12(A-D) - - Project Specs. Min. - N/A 55-90 Max, 4 REMARKS: The concrete test cylinders were temporarily stored at the project laboratory for moist curing and compression testing, com~res. io ./1 re orted sep,arately, as they become available, ' '11 ,J f;v ' Tyleri ewhall Engineering Technician F:\BMC\2000CME\030238\P12.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R l""i@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: July 26, 200(} PROJECT NO: 030238 NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wens~al)tttio_~es Attn: ToiTfSand .- 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 8772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7 -25-00 3067LM Cemstone Strip footing, Grid lines (C, 2,3-3), (8, 3-4) Truck discharge 10 Sunny, 850F T, Newhall Th f II t t rf d t th t k t t d e 0 oWing es s were pe orme a e ruc ,exce D1 as no e : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) (%) Temp, (OF) Cast Added (gal,) Added (gal.) 1 :50pm 278 4% 1.5 80 13(A-D) - -- Project Specs. Min. - N/A 55-90 Max, 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compressi n test results will be reported separately, as they become available, Pete Larson 0 resser Concrete/Masonry qr Inf rm~ . the high Slump ofthe concrete. ~I iv, l~ , Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\P13.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A I.,@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-73-1~ DATE: July 26, 2000 PROJECT NO: 030238 NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmanrt.H~unes AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 8772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 7 -25-00 4067LM Cemstone Foundation wall, Grid lines (8,8-C, 7), (8.8, 6-7 ) Truck discharge 10 Sunny, 850F T, Newhall Th e followma tests were performed at the truck. exce)t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) (%) Temp. (0 F) Cast Added (gal,) Added (gal,) 2:15pm 521 4 1.4 83 14(A-D) - - Project Specs, Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Comp essio te results will be report d se ratel as they become available, I'i lJJ: Tyl Newhall Engineering Technician F:\BMC\2000CME\030238\P14.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A ;.,@ Twin City Testing Corporation TO: 662 Cromwell Avenue, St. Paul, MN55114-1776 (651) 645-3601, Fax: (651) 659-7348 Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: July 31,2000 NOV 2 7 2000 PROJECT NO: 030238 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number B772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; e 0 oWing es s were pe orme at t e true, exce)t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) (%) Temp, (OF) Cast Added (gal.) Added (gal.) 2:00pm 278 5% 1.5 86 15(A-D) 5 2.5 Project Specs. Min. - N/A 55-90 Max. 8 FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: Th f II t t 7-27-00 4067LM Cemstone 1) Foundation wall, Grid lines (A-B, 5), (A, 4.5-5) 2) Column piers, Grid lines (0, 4), (C, 3) 3) Strip footing, Grid lines (A,1, 2-2,3) Truck discharge 10 Sunny, 850F T, Newhall rf d h k REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing, Compression test results will be reported separately, as they become available. Water was added at the project as A,.' au. thori.ze..d by Pete Larson of Gresser Concrete/Masonry, The 5 g .1I0ns water and 2,5 :') . g:!I?~ of PI. sticizen were added before the tests were tak . , / ~ >! 'W, N I/v- Tyler Ne ! hail Engineering Technician F:\BMC\2000CME\030238\P15.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false. fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STOAI~@ Twin City Testing Corporation Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: July 31,200,0, PROJECT NO: 030238 NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmann Homes AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TeST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number B772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; e 0 OWing es s were pe orme a e ruc ,exce )1 as no e : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) (%) Temp. (oF) Cast Added (gal.) Added (gal.) 1 :45pm 388 4 1.9 79 16(A-D) - - Project Specs, Min. -- N/A 55-90 Max. 4 FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: Th f II t t 7-28-00 3067LM Cemstone 1) Strip footing, Grid lines (8, 2.3-3) 2) Column pads, Grid lines (A.5, 2-3) Truck discharge 7,5 Sunny, 750F T, Newhall rf d t th t k t t d REMARKS: The concrete test cylinders were temporarily stored at the project d then submitted to our ress n test r Its will be Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~@ Twin City Testing Corporation Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 TO: PROJECT: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: 1'--"'.'" ".,_ '. 'oO ,i r Aug ust 1, 200~ i ' / PROJECT NO: NO\! 2 7 200n 030238 FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmann Homes AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172. Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 . Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number B772); ASTM:C31 . Making and Curing Concrete Test Specimens in the Field; e 0 owmg es s were pe orme ate rue , exce)t as note : Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in,) (%) Temp, (OF) Cast Added (gal,) Added (gal.) 1 :45pm 351 6~ 0.8 88 17(A-D) -- -- Project Specs, Min. -- N/A 55-90 Max. 4 FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: Th f II t t 7-31-00 4067HM Cemstone 1) Strip footing, Grid lines (A,8, 1,9.2.4) 2) Column piers, Grid lines (A,1, 2), (A,1, 2,3) Truck discharge 4 Sunny, 900F T. Newhall rf d t h t k d REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compression test results will be reported sep.aratelY, as they become available, Jim Gress. er]Of Gresser Concrete/Masonry was~~e. of h' h slump of the concrete. \~^ :_\ ~ Tyler ewhall 't;trk Straight Engineering Technician Staff Engineer F:\BMC\2000CME\030238\P17.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STCJ R I.,@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: August ~~QOO_ PROJECT NO: 030238 i\ 1 '::~~: ~/ " ,.... / -, {"l :" ri PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmann Homes Atth: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 8772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 8-1-00 3067HM Cemstone Column pads, Grid lines (0, 5-6), (C, 4,5) Truck discharge 7 Sunny, 900F T, Newhall Th f II e 0 owma tests were performed at the truck, except as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Corrvnents Tests Number (in,) (%) Temp. (oF) Cast Added (gal.) Added (gal.) 1 :45pm 508 6% 1.0 85 18(A-D) - - Project Specs. Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compression test results will be Aj,. / repo,rte, d separately, as they become available. Jim Gresser f ress r Concrete/Masonry t ~s' for ed 0 e high slump of the concrete, - " ~ I.I.fj I ff//if Tyler Ne haJJ Engineering Technician F:\BMC\2000CME\030238\P18.doc Information and statements in this report are derived from material, information andlor specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~@ Twin City Testing Corporation TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, 81. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-734S DATE: August 3. 209Q NQV 2 7 2000 PROJECT NO: 030238 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPIES TO: 1-Wensmann Homes AUn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott TESTS OF PLASTIC CONCRETE TEST PROCEDURES: ASTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 8772); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: 8-1-00 4067HM Cemstone Column pads, Grid points (C, 4), (A,5, 1.7); Column pier, Grid points (A,8, 2,2) Truck discharge 8 Sunny, gOoF T, Newhall Method of Placement: Total Yards Observed: Weather: Field Technician: The following tests were performed at the truck, exce:>t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Comments Tests Number (in.) (%) Temp, (oF) Cast Added (gal.) Added (gal.) 2: 15pm 389 5% 1.6 86 19{A-D} - - Project Specs, Min. - N/A 55-90 Max. 4 REMARKS: The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing, Compression test results will be reported separately, as they become available. Jim Gresser of Gr sser oncrete/Masonry 'CfIZ"nf med f e high slump of the concrete. j Tyler ewhall M rk St aight Engineering Technician Staff Engineer F:\BMC\2000CME\030238\P19.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18. Chapter 47 STO A l&i@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348' Kelly Murray DATE: August 7, 2000 Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: 030238 Eagan, MN 55122 TO: NOV 2 7 2000 COpy TO: 1-Wensmann Homes AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in, (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: 1A 1B 1C 10 7-7-00 7-7-00 7-7-00 7-7-00 7 28 28 Hold 333 3 1,8 1,8 1,8 1,8 Strip footing, Grid lines, (D-E, 8), (E, 4-8), (O,7-E, 4) 3000 3067HM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping TEST RESULTS: Laboratory Number: 010480-A 010480-B 01 0480-C 010480-0 Diameter, in: 6,00 6,00 6.00 6,00 Height, in: 12,00 12,00 12,00 12,00 Area, sq, in: 28,27 28,27 28,27 28,27 Date Received: 7-10-00 7-10-00 7-10-00 7-10-00 Days on Job & Enroute: 3 3 3 3 Oays Lab Cured (ASTM:C192): 4 25 25 Hold Date of Test: 7-14-00 8-4-00 8-4-00 Hold Time of Test: 4:05pm 8:12am 8:19am To Be Tested Type of Fracture: Shear Shear Shear Load at Failure, lb.: 78940 117800 122330 Compressive Strength, psi: 2790 4170 4330 T e 28-day compression test results meet the sPje;;ed J~- Tyler ewhall ~i9ht ~ Engineering Technician Staff Engineer F:\BMC\2000CME\030238\0 1 0480 .doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except in full, without written approval of this laboratory, The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: August 8, 2000 Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: 030238 NOV 2 7 2000 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COpy TO: 1-Wensmann ~es AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Are a,sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 2A 28 2C 20 7-11-00 7-11-00 7-11-00 7-11-00 7 28 28 Hold 4 4 4 4 1.5 1.5 1.5 1.5 Strip footing, including column pads, Grid lines (C.8-D, 8), (0,7-8), (C.8, 7.2-8) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010493-A 6.00 12.00 28.27 7-12-00 1 6 7-18-00 8:10am Shear 98630 3490 010493-8 6.00 12.00 28.27 7-12-00 1 27 8-8-00 7:55am Shear 129720 4590 010493-C 6.00 12.00 28.27 7-12~00 1 27 8-8-00 8:00am Shear 117820 4170 ession test results meet the specified str ngth. F:\BMC\2000CME\030238\01 0493 ,doc 010493-0 6.00 12.00 28.27 7-12-00 1 Hold Hold Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I.",@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: August 10, 2000 " Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: 030238 NOV 2 7 2000 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COpy TO: 1-Wensmann~Homes -- AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: 3A 38 3C 3D 7-13-00 7-13-00 7-13-00 7-13-00 7 28 28 Ho~ 3% 3% 3% 3% 1.7 1.7 1.7 1.7 Strip footing including column pads, Grid lines (C.8, 7-7.2), (B.8-C.8, 7), (C, 6-7), (B.8, 6-7), (B-C, 6), (B, 5.7-6) 3000 3067LM Cemstone T. Newhall TEST PROCEDURES: ASTM:C39 - Compression Test; ASTM:C1231 - Capping TEST RESUL TS: Laboratory Number: 010514-A 010514-B 010514-C 010514-D Diameter, in: 6.00 6.00 6.00 6.00 Height, in: 12.00 12.00 12.00 12.00 Area, sq. in: 28.27 28.27 28.27 28.27 Date Received: 7-14-00 7-14-00 7-14-00 7-14-00 Days on Job & Enroute: 1 1 1 1 Days Lab Cured (ASTM:C192): 6 27 27 Hold Date of Test: 7 -20-00 8-10-00 8-10-00 Hold Time of Test: 11:10am 9:05am 9:11am Type of Fracture: Shear Shear Shear Load at Failure, lb.: 98290 137290 135120 Compressive Strength, psi: 3480 4860 4780 Tyler Ne hall Enginee ing Technician F:\BMC\2000CME\030238\010514,doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A I..,,@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 65,~"-7~48 August 14, '2000 ' 030238 NOV 2 7 2000 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COPY TO: SHOWROOM/WAREHOUSE PRIOR LAKE, MINNESOTA 1-WensmanrrHomes AUn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: REMARKS: 4A 4B 4C 40 ~1~00 ~1~00 ~1~00 ~1~00 7 28 28 Hold 2% 2% 2% 2% 1.8 1.8 1.8 1.8 Strip footing, Grid lines (B, 4.2-6), (A.1, 4.5-5), (A-B, 5), (A-B, 4.5) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010531-A 6.00 12.00 28.27 7-17-00 3 4 7-21-00 10:25am Shear 86430 3060 010531-B 6.00 12.00 28.27 7-17-00 3 25 8-11-00 11 :15am Shear 122620 4340 010531-C 6.00 12.00 28.27 7-17-00 3 25 8-11-00 3:25pm Shear 127300 4270 010531-D 6.00 12.00 28.27 7-17-00 3 Hold Hold The 28-da compression test results meet the specified Tyler ewhall \. Engineering Technician ~ F:\BMC\2000CME\030238\0 1 0531.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full. without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO AI~@ Twin City Testing Corporation TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 -. ; . J i Kelly Murray DATE: August 15, 2000 Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: 030238 Eagan, MN 55122 NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPY TO: 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: 5A 5B 5C 5D ~1~00 ~1~00 ~1~00 ~1~00 7 28 28 Hold 555 5 1.5 1.5 1.5 1.5 Strip footing including column pads, Grid lines (D-D.7, 4), (0, 3-4) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping TEST RESULTS: Laboratory Number: 010541-A 010541-B 010541-C 010541-D Diameter, in: 6.00 6.00 6.00 6.00 Height, in: 12.00 12.00 12.00 12.00 Area, sq. in: 28.27 28.27 28.27 28.27 Date Received: 7-18-00 7-18-00 7-18-00 7-18-00 Days on Job & Enroute: 1 1 1 1 Days Lab Cured (ASTM:C192): 6 27 27 Hold Date of Test: 7-24-00 8-14-00 8-14-00 Hold Time of Test: 8:00am 10:30am 10:35am Type of Fracture: Shear Shear Shear Load at Failure, lb.: 79240 142380 139860 Compressive Strength, psi: 2800 5040 4950 Tyler Ne hall Engineering Technician F:\BMC\2000CME\030238\0 1 0541 ,doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO A l&i@ Twin City Testing Corporation TO: 662 Cromwell Avenue, St. Paul, MN ,55114,.1776 (651) 645-3601, Fax: (651) 659-7348 ' Kelly Murray DATE: August 15, 2000 NOV 2 7 20r1unL Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: 030238 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COpy TO: 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 6A 6B 7-18-00 7-18-00 7 28 4 4 1.5 1.5 Strip footing, Grid lines (A, 2-4.2) 3000 3067LM Cemstone T. Newhall 6C 7 -18-00 28 4 1.5 6D 7-18-00 Hold 4 1.5 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010551-A 6.00 12.00 28.27 7-20-00 2 5 7 -25-00 8:10am Shear 88520 3130 010551-B 6.00 12.00 28.27 7-20-00 2 26 8-15-00 7:45am Cone & Shear 129790 4590 010551-C 6.00 12.00 28.27 7 -20-00 2 26 8-15-00 8:25am Shear 137300 4860 REMARKS: The 28-day compression test results meet the specified st ength. Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\010551.doc 010551-D 6.00 12.00 28.27 7-20-00 2 Hold Hold An Affirmative Action * Equal Opportunity Employer STCJ R I~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 Kelly Murray DATE: August 16, 2000 Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: 030238 Eagan, MN 55122 TO: i. NOV 2 7 2000 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COPY TO: 1-Wensmann Homes Attn: Tom sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: Tyle Newhall Engineering Technician F:\BMC\2000CME\030238\O 10566.doc 7A 7B 7C 7-19-00 7-19-00 7-19-00 7 28 28 3% 3% 3% 1.5 1.5 1.5 Strip footing, Grid lines (A, 1-2), (A-A.8, 1) 3000 3067LM Cemstone T. Newhall 7D 7-19-00 Hold 3% 1.5 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010566-A 6.00 12.00 28.27 7-21-00 2 5 7-26-00 10:39am Shear 91450 3230 010566-B 6.00 12.00 28.27 7-21-00 2 26 8-16-00 8:51 am Shear 137910 4880 010566-D 6.00 12.00 28.27 7-21-00 2 Hold Hold 010566-C 6.00 12.00 28.27 7-21-00 2 26 8-16-00 8:55am Shear 149280 5280 compression test results meet the specified s ength. Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STORI.,@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-734S', TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 August 17, 2000 NOV 2 7 2000 030238 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIWAREHOUSE PRIOR LAKE. MINNESOTA 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: j, 8A 88 8C 80 7 -20-00 7 -20-00 7 -20-00 7 -20-00 7 28 28 Hold 444 4 1.7 1.7 1.7 1.7 Strip footing, Grid lines (B, 1.7-2), (8-C, 2), (C, 2-2.3) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010574-A 6.00 12.00 28.27 7-21-00 1 6 7-27-00 8:25am Shear 82300 2910 010574-0 6.00 12.00 28.27 7-21-00 1 Hold Hold 010574-B 6.00 12.00 28.27 7-21-00 1 27 8-17-00 8:05am Shear 131030 4630 010574-C 6.00 12.00 28.27 7-21-00 1 27 8-17-00 8:10am Shear 135110 4780 REMARKS: The 28-day compression test results meet the specified strength. ~!1if{(JJ~ ~ j Tyler1eWhaII Engineering Technician F:\8MC\2000CME\030238\0 1 0574 .doc ... "..., Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I.,@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 030238 August 17, ~OOp,_ TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA NOV 2 7 2000 1-Wensma~_n!i~me~ Attn: Tom Sand - 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 9A 98 9C 7-20-00 7-20-00 7-20-00 7 28 28 3~ 3~ 3~ 1.5 1.5 1.5 Foundation wall, Grid lines (C.8-D, 8), (C.8, 7-8) 4000 4067LM Cemstone T. Newhall 9D 7-20-00 Hold 3~ 1.5 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010575-A 6.00 12.00 28.27 7-21-00 1 6 7-27-00 8:30am Shear 107860 3820 010575-B 6.00 12.00 28.27 7-21-00 1 27 8-17-00 8:20am Cone & Shear 170230 6020 010575-C 6.00 12.00 28.27 7-21-00 1 27 8-17-00 9:25am Shear 174310 6170 010575-D 6.00 12.00 28.27 7-21-00 1 Hold Hold The 28-day compression test results meet the specified strength. ~~Jl~ M rk S\raight ~ Tyler N hall Engineering Technician F:\BMC\2000CME\030238\O 1 0575 .doc Staff Engineer Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STCJ R I~@ Twin City Testing Corporation Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 I' DATE: August 22, 2000 PROJECT NO.: ^.In/ " 7 ""'l,...........-. 030238 COpy TO: 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: 10A 10B 10C 100 7-21-00 7-21-00 7-21-00 7-21-00 7 28 28 Hold 5% 5% 5% 5% 1.5 1.5 1.5 1.5 Strip footing, Grid lines (C.8-D, 3), (B, 1-1.7), (A.8-B, 1), (C, 2-2.3) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping TEST RESULTS: Laboratory Number: 010586-A 010586-B 010586-C 010586-D Diameter, in: 6.00 6.00 6.00 6.00 Height, in: 12.00 12.00 12.00 12.00 Area, sq. in: 28.27 28.27 28.27 28.27 Date Received: 7 -24-00 7 -24-00 7 -24-00 7-24-00 Days on Job & Enroute: 3 3 3 3 Days Lab Cured (ASTM:C192): 4 25 25 Hold Date of Test: 7-28-00 8-18-00 8-18-00 Hold Time of Test: 8:03am 11 :20am 11 :23am Type of Fracture: Shear Shear Shear Load at Failure, lb.: 88670 140240 133520 Compressive Strength, psi: 3140 4960 4720 Tyler whall Engineering Technician F:\BMC\2000CME\030238\0 1 0586 ,doc pression test results meet the specified strength. ~J~/ M1k StJ.aig Staff Engineer Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I..,@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COPY TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA August 22,200.0 I ,.' L~_J 030238 d NO V 2 7 ?nr1 1-Wensmann Homes Attn: Tom'SaiU:t~u 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 11A 11B 11C 11D 7-24-00 7-24-00 7-24-00 7-24-00 7 28 28 Hold 6X 6X 6X 6X 1.5 1.5 1.5 1.5 Strip footing including column pads, Grid lines (8, 4-4.5), (C-C.8, 3) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010603-A 6.00 12.00 28.27 7-25-00 1 6 7-31-00 9:50am Shear 88530 3130 010603-B 6.00 12.00 28.27 7-25-00 1 27 8-21-00 2:25pm Shear 121470 4300 010603-C 6.00 12.00 28.27 7-25-00 1 27 8-21-00 2:45pm Shear 128350 4540 010603-D 6.00 12.00 28.27 7-25-00 1 Hold The 28-day compre sion test results meet the specified s rength. Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\01 0603 .doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R Ittti@ Twin City Testing Corporation TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive. Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA 662 Cromwell Avenue. St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 August 22,2000 030238 NQV 2 7 2000 ; 1-Wensmal1n Homes AUn: Tom.S'arn:L u_. 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 12A 12B 12C 7-24-00 7 -24-00 7 -24-00 7 28 28 444 1.5 1.5 1.5 Column piers, Grid points (D, 7), (C, 6) 4000 4067LM Cemstone T. Newhall 12D 7 -24-00 Hold 4 1.5 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010602-A 6.00 12.00 28.27 7-25-00 1 6 7-31-00 10:00am Shear 122300 4330 010602-C 6.00 12.00 28.27 7-25-00 1 27 8-21-00 2:40pm Shear 149690 5300 010602-D 6.00 12.00 28.27 7-25-00 1 Hold 010602-B 6.00 12.00 28.27 7-25-00 1 27 8-21-00 2:35pm Shear 154730 5470 The 28-day compression test results meet the specified strength. ~ . I F:\BMC\2000CME\030238\0 1 0602 .doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I.,@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COPY TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA August 22, i20pO, 030238 NOV 2, 7 2000 1-Wensmahn'H<>ffie~ AUn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished 8y: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 13A 13B 13C 7 -25-00 7 -25-00 7-25-00 7 28 28 4% 4% 4% 1.5 1.5 1.5 Strip footing, Grid lines (C, 2-2.3), (8, 3-4) 3000 3067LM Cemstone T. Newhall 130 7-25-00 Hold 4% 1.5 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 01 0646-A 6.00 12.00 28.27 7-26-00 1 6 8-1-00 8:20am Shear 78230 2770 010646-8 6.00 12.00 28.27 7-26-00 1 27 8-22-00 10:40am Shear 132630 4690 01 0646-C 6.00 12.00 28.27 7 -26-00 1 27 8-22-00 10:45am Shear 133880 4740 ~~~ ~ompreSSion test results meet the specified Tyler Newhall Engineering Technician F:\BMC\2000CME\030238\0 1 0646 .doc 010646-D 6.00 12.00 28.27 7-26-00 1 Hold Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO AI~@ Twin City Testing Corporation TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348._ Kelly Murray DATE: August 22, 2000 Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: 030238 NOV 2 7 2000 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COpy TO: 1-WensmanA Homes- AUn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 14A 14B 14C 7-25-00 7-25-00 7-25-00 7 28 28 444 1.4 1.4 1.4 Wall, Grid lines (8.8-C, 7), (8.8, 6-7) 4000 4067LM Cemstone T. Newhall 140 7 -25-00 Hold 4 1.4 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010645-A 6.00 12.00 28.27 7-26-00 1 6 8-1-00 8: 1 Oam Shear 103320 3650 010645-B 6.00 12.00 28.27 7-26-00 1 27 8-22-00 9:45am Shear 160230 5670 010645-C 6.00 12.00 28.27 7-26-00 1 27 8-22-00 10:35am Shear 159570 5640 010645-D 6.00 12.00 28.27 7-26-00 1 Hold ~ compression test results meet the sp~ed st en tho Tyler ewhall Engineering Technician F:\BMC\2000CME\030238\0 1 0645.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I.tt;@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIWAREHOUSE PRIOR LAKE. MINNESOTA August2,4r 2000, 030238 NOV 2 7 2000 1-Wensrnann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 15A 15B 15C 7-27-00 7-27-00 7-27-00 7 28 28 5% 5% 5% 1.5 1.5 1.5 1) Foundation wall, Grid lines (A-B, 5), (A, 4.5-5) 2) Column piers, Grid lines (D, 4), (C, 3) 3) Strip footing, (A.1, 2-2.3) 4000 4067LM Cemstone T. Newhall 15D 7 -27 -00 Hold 5% 1.5 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010630-A 6.00 12.00 28.27 7 -28-00 1 6 8-3-00 8:40am Shear 102160 3610 010630-6 6.00 12.00 28.27 7-28-00 1 27 8-24-00 1 :20pm Shear 144560 5110 010630-C 6.00 12.00 28.27 7 -28-00 1 27 8-24-00 1 :35pm Shear 137900 4880 010630-D 6.00 12.00 28.27 7-28-00 1 Hold REMARKS: The 28-day compression test results meet the specified strength. ~, iillMff rIA I~~ Tyler 'ewhall ~ralght Engineering Technician Staff Engineer F:\BMC\2000CME\030238\010630.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA 030238 .- 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake Attn: Susan McDennott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 16A 16B 16C 16D 7-28-00 7-28-00 7-28-00 7-28-00 7 28 28 Hold 4 4 4 4 1.9 1.9 1.9 1.9 Strip footing, Grid lines (B, 2.3-3), Column pads (A.5, 2-3) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010641-A 6.00 12.00 28.27 7-31-00 3 4 8-4-00 10:12am Shear 87820 3110 010641-D 6.00 12.00 28.27 7-31-00 3 Hold 010641-B 6.00 12.00 28.27 7-31-00 3 25 8-25-00 10:05am Shear 124430 4400 010641-C 6.00 12.00 28.27 7-31-00 3 25 8-25-00 10:10am Shear 118880 4210 REMARKS: The 28-day compression test results meet the specified s rength. ,~~ ~ Tyler Newhall Engineering Technician F:\BMC\2000CME\030238\010641.doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STORI~@ Twin City Testing Corporation Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA TO: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: August 28,2900 030238 NOV 2 7 2000 PROJECT NO.: COpy TO: 1-Wensmanh Homes Attn: Tom Sand. 1-City of Prior Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: REMARKS: 17A 17B 17C 7-31-00 7-31-00 7-31-00 7 28 28 6X 6X 6X 0.8 0.8 0.8 Strip footing, Grid lines (A.8, 1.9-2.4); and Column Piers, Grid lines (A.1, 2), (A.1, 2.3) 4000 4067HM Cemstone T. Newhall 17D 7-31-00 Hold 6X 0.8 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010651-A 6.00 12.00 28.27 8-1-00 1 6 8-7 -00 8:30am Shear 84860 3000 010651-8 6.00 12.00 28.27 8-1-00 1 27 8-28-00 11 :50am Shear 131790 4660 010651-C 6.00 12.00 28.27 8-1-00 1 27 8-28-00 12:45pm Shear 128670 4550 010651-D 6.00 12.00 28.27 8-1-00 1 Hold The 28-day compression test results meet the specified strength. 1M~.~ Tyler Newhall Engineering Technician F:\BMC\2000CME\030238\010651 ,doc ~^ -- Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348- TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COPY TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA , . r ,_ August 29, :2000 NOV 2 7 2000 030238 1-Wensmann Homes- AUn: Tom Sand 1-City of Prior Lake AUn: Susan McDennott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 18A 188 18C 8-1-00 8-1-00 8-1-00 7 28 28 6X 6X 6X 1.0 1.0 1.0 Column pads, Grid lines (D, 5-6), (C, 4.5) 3000 3067HM Cemstone T. Newhall 18D 8-1-00 Hold 6X 1.0 ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010670-A 6.00 12.00 28.27 8-2-00 1 6 8-8-00 9:43am Shear 62420 2210 010670-B 6.00 12.00 28.27 8-2-00 1 27 8-29-00 9:50am Shear 110410 3910 010670-C 6.00 12.00 28.27 8-2-00 1 27 8-29-00 10:15am Shear 113950 4030 010670-D 6.00 12.00 28.27 8-2-00 1 Hold R;~: ;:S-day compression test results meet the S~Cj:A st~ Randy Schlegel - ~rk S\raight Supervisor Staff Engineer F:\BMC\2000CME\030238\0 10670 .doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO R I..,@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA August 29,2000-. 030238 ! NOV 2 7 2000 1-Wen$mann Homes Attn:lTom.$and 1-City of P riot Lake Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished 8y: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: REMARKS: 19A 19B 19C 19D 8-1-00 8-1-00 8-1-00 8-1-00 7 28 28 Hold 5% 5% 5~ 5% 1.6 1.6 1.6 1.6 Column pads, Grid points (C, 4), (A.5, 1.7); Column Pier (A.8, 2.2) 4000 4067HM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010669-A 6.00 12.00 28.27 8-2-00 1 6 8-8-00 9:35am Shear 92050 3260 010669-8 6.00 12.00 28.27 8-2-00 1 27 8-29-00 10:30am Shear 151600 5360 010669-C 6.00 12.00 28.27 8-2-00 1 27 8-29-00 10:35am Shear 155970 5520 010669-D 6.00 12.00 28.27 8-2-00 1 Hold The 28-day compression test results meet the specified strength. i~~'.' Staff Engineer F:\BMC\2000CME\030238\01 0669 ,doc Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 16:16 6123226147 GENZ-RVAN PAGE 01 Fax To: 1rLr,~s From: ~J Co: Co: ..: Phone: (651)423-1144 -.,.., . D."~ Fax II: (651) 322.6147 (651) 322-1469 Service Department o Urwent o For Rev"w D P..... Comment 0 PI._. Reply o PI.... Recycle Conll".nu: ~ i/ ~dJ , I ~,'~~-fl r" t-I~~ NUMIII!R OF PAGES (INCLUDING C:OVI!R .HEET): L 15:15 5123225147 GENZ-RVAN PAGE 02 P.o. Be. 27316 GaIda Vdey, MN 55427 SCOTT D. KNEE~ P.E. RJ:GlSnDD MEC'ILUIICAL &NGllUER Beada., Vatlldaa. AIr C~I,'" .........1 Balp .....; (6IZ>--9-907I .a_r: (612).901'-'5 October IS. 2000 To: Raben Hutc.bim City of Prior lAke 16200 Eap: Creek AWDUe Prior Lab, MN 5'372 RB: Foumain Hills SbowrOCInIWanhouse PriOl'Lake, MN Dear Robert, ~,.,...., As per QW' pboDe CODVcnatioo, 11NOUId 1ikc to CODfinn the following four issues we discussed and allO advise Todd Boyum. wirh Gcuz-Ryan. 9 fo-A '5~ l44o~frt\ Inlle .1: QmIde air lor acc:eptabIe iadoor qaaIIty. SbowrocmIWarebouae areas are provided widJ 1440 eFM CJUISide air to satilfy ASHRAE 62..1989 for 96 occupants (ccat:inuous) or 192 oecupantl when peak is 3 boars or ... (pqe 2). ArdIitrd auticipalcs 10 employees ud 40 custunen at peak OCQlpancy. If you do DOl asnc with this desip, Gcoz-Ryan wiD install a CO! sensor and alarm (set for 800 ppm) to Itlert GWDIII' ~ u",~~1e COt lcwU. (See ... 4 - 1000 ppm l".nIIIi"~JOUI_) lime a: How.no c...Ry_ werify outsidE air ill die ....... of lS% i.~, Assume manual dampen Ie! OD day wbm the c.'JUbide air is -soF and rd:um air is 70oF. Gc:nz..Ryan will opc:n dampet until mixed airtc:mpcnd.ure is 51.750F. M.A. tallpcnduJe = .1S(-SOF) + JIS(700F) == -.7soF + '9.,SoF =: SI.7soF 1- G; CuIII -".,<-:o.lIir for eadI Uait ~ .. Provide ccmbuation air iDtake area grraICr than or equal to the ftue pipe SIal. I... N4: Relief air from lower Ieftl cast of6c:a... PnMde a IOxID-relief.grille (1I2"JC.112" ..crate) ud . l(bc 1 0 relief duct fiom cad1 ofticz. Grine and dud will transfer 120 CFM at . duct vdoc1ty lesa tIwI 2'0 fi:d: per aninutc. PIc:ue call (612) 849-9071 ifyau have any quostioDs. Siocerdy _ Ju.tt tJ. '?J -- - YL SCCG D. x..n. P .E. Copy; Todd Boyum Gcu-R,- GENZ-RYAN ,,+8- i" {, f 1'AIILE :I 01.J'lbOOlt AI. REQUIIlDIEN'I'S lOR yItNDLAnON- (Colltl,,1MtII) 11 COMMEllCIAL FACIUllES (of'" do,... "'Opt, bo-, ....... ladlllll:l) Ouldoor AIr ......... LI.. cla/.... ,.... 16:16 6123226147 . ^"hU.. ......... ~..... O~;,; ~ P/l_ ..,1..2 ~I ....... LlI..1 PAGE 03 c......,. ....:....... ... 1Ioen. ... ....'...~ '......t lIDd Met 'U' .. ,noon ~ ' ~ '~".. . . .. '~d ~YJ'" ~ ~~.10UUle .....~ ~..' :B' ,.. '~,:.al " '~.' "" OCII 1'1 ., rufnJUolR: dl1lp, fabric 5 ,..' \ . ~ .. - . ,:;,,;:,:",~ . ~: i .:,..,,:_J'::'~) " ". . '~:,":i'P. : ;~t.;:' , ',. .' ,:ft9Dn (,un,aulum) , ,. . uddIKQI . ,~~:.u. (_URI :,~!:,,' '~ . :_booIJu "'~~~ ,~;..cUoe ,~. , _.room. '~ttorm. \WdOI~" .' j :,,,).j~r., l~ '~~~~~ .' ".. ... ~, ~...~' t 30 )0 I' 110 4-;:: ~ fiG 30 2S U 8 2J Z-' J3 zo IS I 8 15 8 8 U' 8 8 U 8 150 IS 8 70 25 13 30 20 10 100 25 13 70 2$ 13 fir) 20 10 ISO 20 10 1'0 U 8 70 J5 8 100 IS 8 100 IS 8 UO IS 8 10 lS 8 0.30 0.20 0.1$ 0.20 0.20 O.U O.OS 0.30 2.50 1.00 S.OO 0..50 2.50 0.50 2oJO z.. (/ " ,: 1.-.1 r&-' ,. · 1khJe 2.......JUppl, ""' of acapcable 0~1doof air lIIlIuinld (or ~cp&abli btcIoar "t'..IIIlk~ n.- ~_1IaYe .... choten. to ~oDClDl COz aM athw con. 1mft1MD&.e witllulllllecauae IDUlin of...fcty 8DcIlO I&:COUnt fOr health "lII"IauOllll . 171~~e.t...lftheoUldooraireon.. tuninant eve s e:cceed the va1u~&i"Cn in 6.1.1 ('D1blc 1). the air should 1:Je tleated to conued the oIFendina c:ontamlnanu. Air-cJ_nin8 .,.terns suitable for Ehe p.rticJe size eq- co,untered .hould.be used. For removal of gues and \'Ilpon. ASHKAB ~JU) 6z..1,., . iYt' J.l.lt?"'~\>::vt~,-rl ,+ "," . r ~ 1.50 1.00 0.75 1.00 1.00 o."s 0.2' NGI1n.JI~ auppllcd by Iran.rer air. loceJ mechallicaJ qbau'l; aPliutl with 110 n:cirt\lla.ion ~om.nended. Vaatlladon to optJmize ....nt ,rowlb may dictate nqu'RIIlen~. When inlCh\al ~ombu.tion wines are operattld for Ih.intc....nc:c of playin..urfa.. inc~.ed "CncUa- lion ...ra may be rwqubed. Hilhcr _lues mllf be rwquirecl ror humidity &:ontto'. Special ~tilalion wJII be needed 1.0 eliminate .p<<i&I.la,c t:n~tJ (c..J.. dry ice Wlpor., lIli.t.. etc.) Vwmtilation wi,hin vchlc:le.s may ~uire .pcci" c:oIllJdcraUon" SpaaII mall.wlled at low t.mJ)cra~ tu.... ( - . O.p 10 + 50 -P, 01' - Z3 lie to + 10"C) ate nol ~ by rbac .,:quln:rncnls IUlIeu Ihe ~cu. panc,i.conunuou.. ~nlUaUon from adjol... .pac. '* penniui- blc. When tbe or:cu"lKY I. Inter- JIIitlent. inlJluadon will normall~ ~ the ....dJatlon requlrEmc,u. (~ JeI.I). nd. mOCknlc aQIOUOI of .mo~in&, R.lion.1 ppeudla D, apPlOpriate air-dc:ardDSIYiteml should be used. Where the best available. demon.trated, and pro~en tcchnololY does not .now for the re.rnoYlll of contaminants, the amount of outdoor ail" may be reduced durin! periods of hiah con- taminant levels. luch as thole lederaled by ruth-hour .CD "I~ f ,,^ 16:16 6123226147 Je deli1lel'ed to lhe conditioned space at all times tbe Duilding is in use except as modified in &.1.3.4. Properly c:1~ed'air may' be ~irculated. Under the ventilation ratc procedure. for other than intermittent variable occupancy as defined in 6.1.3.4. outdoor air flow rates may not be reduced below the laIUir:emenls in D.ble 2. Jf clel'ned~ recirculated air is used to reduce the outdo'or air flow rate below the values shown in lllble 2,' the Air Quality Procedure, 6.2., must be used. Tbe air~cleaning system for the rec:ireulated air may be located in the recir- culated air or in the lIlixed ou~door and rec:irculated airstream (see Fig. 1). The recirculation ratc for the system is determined by [he airadeaning Iy&tettl efficiency. The recirculation rate must be increased to achieve full benefit of the air...cleanina system. The air-cleaning uscd to dean recirculated air should be designed to reduce particulate and, where neces"uy and feasible. pacous contall)jnants. The system shaU be atpable of proYidinl indoor air quality equivalent to thar obtained uains outdoor air at . rate specified in Thblc 2. Appendix B may be referenced for assistance in calculatinl the air now requirements for cornmonl)' used air distribution syslan$. 6.1.3.3 Ve......tao. EfIedIW'IIaI. it.: Outdoor air for cOnlrOlUnl contaminant cODcentration can be used for dilution or for sweeping the contaminants from their source. The values in 'I1lble 2 define the outdoor air need- ed in the ocxupied. zone for well..rnixed conditions (ven- tilation effectiveness approaches IOOlVo). The ventilatio effectiveness is defined by the fmetion of the outdoor delivered to the space that reaches the occupied zone. Ventilation effectivenC'$s may be increased by creatins ~ 1.0 , = Correcled fra~'on of olltdoor air an total .upply X ~ SUItt of ... z..... outdoor airflows Oh,lded '-y 10181 .uppl, z . Ou'.oor e', tracllon reqy're<t In ..,ppl, 10 erlUcal .pee. 0.8 y 0.6 y a X/(1.X~Z) 0.4 0.2 o o 0.4 0.8 '.0 0.8 X 0.2 n~. J Yelltll_tion R_dllctiDIf I" Mlllt/plt: ~$ Slip plied fro", Q Co,"mon SOIl~ ,. ~ ~; --. Ii:.., 12 - GENZ-RVAN PAGE 04 a plug flow situation. If the flow pattern i$ such that the ventilation air nows paSt the contaminant sOUrce and sweeps the contaminant toward an exhaust, lhe contami~ nant eoncentretion in the exhaust can be greater than that for tbe wcllRmixed condition. Ventilation effectivc:ncss can then be greater than that which would be realized with perfect mixing. Local exhaust systems oPerate in this way. With perfect mixing between the ventilation air and the air in a space, ventilation effectiveness is 100.,.. With per- fect mixing, Ev ;;;; 1.0. It is, however, nOl uncommon to find some of the ventilation air bypassing the occupants (movilll from supply to shaUSI wilbout fulJy mixing in the occupied zone) and achieving E.. ,,-lues .s low u O.S (see lkf 26). Such Oow conditions"should be avoided. The abili.. 11 of tbe ventilation air to mix in the occupied zone can be improved through reciJCulation or acdve mixing of the air in the space. Additional information abOut ventilation effectiveness can be found in Appcndi" F. 6.1.3.4 laknaJeteo. or .rlable ocC!..pa.C'Y. Ven~ tilaling systems for SPaces with intermittent Dr variable occupa~ may have their outdoor air quantity adjusted by use of dampers or by stopping and starlins the ran s)'Stem to provide suffic:itnt dilution to maintain contaminant c:on- cennations within acceptable leYcJs at all times. Such syslem adjustmeot may 1al or Ihould lead oc:cupancy d . oa:upa.ncy. \IZh~"V'., -' enJy wi e-'Fr-t---.w;"r .' .. , L __. y.h_M'.'Ihort-term heak&a..- ( i. ~nn .. 1 J__h..~..noc:cupied ~!\" ;~. &a.pv': jn ... ~~.'. r... .r, HL &iitd'oor'air, ~~.A 1. & ..'J~~ ~ ',' ~J'!P""'.J. Wh~n con- ASHRAE STANDARD 62..1~'9 ~, @ t" .~ .-; 16:16 6123226147 ,.J Qulllld..Uw ~u,'lo". >>le 1 furnishes infonna- .Ion on ac<:eptable tontaminant ll:\lels in outdoor air. This table also applies indoors for the same CJlpoSUl'e times. For additional information on contaminants in the outdoor air, See! 6.1.1. lablc 3 contains Umiu for four other indoor COft~ raminants. Three of these are limits set ,by other bodies as dicated in the table. The limit for 002 was "ecrted,'ba'Rd o' . . . q:.g~..p's!!;nt,iJ.l",.. c;ontaminants for which defmite limits baw not beaa set are _ cli!K:lIued in Appendix C. Tables C-l and C-3 do not include all known contaminants that may be of concern, and these concentration limits may not, ipso facto. ens~ acceptable indoor air quality with rcspcc;110 otber contaminants. f1fl1mlkl.....--1. l' L. .b(\)QJ)..4ioxi4e. water vapor. particulateS, biololica1 aemlOls, and Or.~r 'contam- inants. ~bon diGidCG8Il.......-.don.bas been ~id~y,~ as an jodieator of iDd~~'4~.ty. A. -limit of .IOOOlpPjn ~- PR GENZ-RVAN PAGE 05 "t:"1.)~ :- ~mmendad.. ' odor:).Qriteria. 2 ro Y any me 0 lion. the effects of the possihle elevation of olher contam.. \ inants must be considered. In recent years a nwnber of indoor contaminants have ~. received increased attention and emphasis. Some of these contaminants, such as formaldehyde or other vapor pha .organk.,co....y. ndI, are,,~rat~)~y ~he b' . contentS, and its site. Another imponanl Iroup of con- taminants is produced by unvented indoor combustion. The presence and use of consumer and hobby products. as well as cleaning and maintenance products, introduce a range of largely episodic releases of contaminants to the indoor environment (see: Ref 30). There ate allaO comple.. mixture&. luch as environmen- tal tobacco smoke (see Ref 31). infectious and aJJergenie biologic aerosols, emanation$ from human bodies, and . ( . It, &. Compute the air capacity per penon in lhe space in ft' (m'). b. Find the required ventilation rale..ln cfm (LIs) pet person. ~ Bnlel' Fiaure 4 with these values and read the maximum permissible vend- lation I.. time after Ot,up.n~ from the intcna:tion of & and b. 50 ~ 50 25 ~ '" g:: ~ 10 5 z: A.. ....... 0 ~ Vl a: U w ~ --. '" 5 2.5 """ -~, , O. 1 5.0 0.5 10.0 J 1.0 HOURS PERMISSIBLE LAG TIME FI6." M~""..", ^,,,,i&rIb/~ V,mtil",ioll Ltl6 Tim, ASHRAE STANDA.RD ~J9.9 -~, @ pall~es. AE aiM) rccomm....dll ill UIe Q. .uidclinr: for other buildln. occu- pandea until ~f1c l'eCommcnclaUonl (or ot_ QCCUp...clq are published by.p. proprlale 111l1'''oril)', , 'I acceptable tcc:hnolo&>'t and vigilance telarding adverse influences of reduced ventilation. must therefore suffice. f Ap~ndix C contains information on Itandards and B\.Iide- f. Jines for .seleaed air contaminants. Uniform governmental t policies rcsardina limits on cxposu~ to environmental car- EO.tenS have not )lC'l emCfged. < -A ~ 16:16 6123226147 GENZ-RYAN " '.. . . . '.. ... ..', ' "l"l YULE J ... ~ GUIDELIPiD FOR SEJ.tcrED .~.* CON'tAMtNANTS OF'I~1t OK.~.n ..' :. ~....~.-=t...... .. '. :." ,,'.. "ta"'~., E"poslln: '1"._ Co....... I.a aIm' J "'/01' 100 IJ&Im' . pCI/L (29, 3:1)b CGntin..ous Continuous Continuo". J\?'1"al AYa1lIC Sft Appendia D Refen:rx:e 27 Ilef....1ICZI 2' For alalia. hou.. lIlIn ac:eed . L ace Z9 Carbon DiOJCick: Chlo("da.... OJQIIC! Radon 811I -~-'.;~ "Thi, kwl I, no( con.dCied a _Ith ri_ bu. it a surroptc (or h",man c:ornfor. t'*"). See SeedoR 6.1.) .nd Appandi. D. This SPA I'KDINIMlndall~ .pPIia IJ*;iflGBlly la residential .nd .mool ~u. ernanatign. from food preparation. PRlCise quantitati~ lRatmcnl of these contaminants can be difficult. 1b some degree. adequacy of control must rest upon subjective evaluation. (n the c:::Qe of sam., odorless biolosic aerosob, subje.:- rive evaJuadon is irrelevant. Application of .enerally PROCEDURE ~'.'" a. Compute the air (:apacity per per$on in the space in ftl (m~). b. Find the requind ~ntil.tion rate, in dm (LIs) per person. ~ Enler Flaure , with these values and n:ad tbe minimum req\li~ WIlU- lacion lead time betore occupancy from the inlenecdon of. and b. ..... '" ~ ffi 10 ~ :! u 5 .~ ~;. iJil::_'IJ: -".. . ..~~:.:~'i\.~ 1." Ii".. . 1 0.1 0.5 10.0 1,,0 HOURS REQUIRED LEAD TIME 'II. 5 Miltl",.,,,, Vntli/tll;on Time ReqJiI;~d Jhd'orr Occuptlncy qf St;N1c:e 5.0 PAGE 06 ,f \ 1 ) I' I '. ...._, ~ ..-' 5 z o en a:: LoU ~ -.. ." -.. 2.5 @ .. \ Operall".......lllon .eF to 122." (O.e,; 10 50"'\';) I 5 to 8'~ RH. 1'10n OO,.d..,ei"SI I I AI~ .pprDV.' .- -'@- r v_ ..... - 1 1 ., ~ ,:~ ~ 'i ~ I I OCT 11 '00 rag: 29RM MINVR....CO r1=t.S 920 ..'. .' ....' "~_..: _'.:'.' ;....,.";. y~. " . ;' '. ,.,.; '14,' \'V"'... ;.\ ~ .~~~" t., .')., ..~.,~,~V,. ..::',;.',1. .:'~, i..'!.f~t:!fIIJ\\-r. 4 , ; ::1 I"~I.".( J"!fll:I" 'J' ,..~ ':,' '., ~li:.;;>, ::;i!<~: F::': 'j~~, . :,'r'~f:* 'f: '" Ie I .:' '~JII ':.' l,tt1fl; '~~ <t ~..,f;.,~1t ;~(~~~'~,."~ '! I: I': ':i fl. 'lti if ,,;F: .........,., ':;~~. ".~ . '. ' .' -I' .. '. . ; ;. -I 1 ,1111 J'" 'I . ~ .:... ,.. . :.': .,.... , 1-' -" 11" f, i .. ~ A · ":~? . . .:. ' '. '. . ' ..' .. IIJ I,. ;,.: ~II ~c., ,'. ,,'. . . . . I . I II' '1 ~t .~~~' ~ .1. .' ' . . · '. .. :'O:.ltl~< ..~ ;1' .. :< 0 " . 7 atlllfj.JI.J'UI"M~IJ:::r .1,. ."0 .. . I ~ I 1 J ) fJ 1 a." ~ll' , · . II c . ~ I . , .' I" Iii.. 11...ll-1J1I,., ; H I ~ .: .' JI .!ijlltj.J1J.. !l=: .' . ! :~ i! .1 ; .j : .!i~l!j.ji.ll~l,,'.' .J.if!t i. ...." . . ! j '1 I. ..,' fl'.-. ':'~'i..: ::' . . . .:~~. '. '.,' . J 16:16 6123226147 GENZ-RVAN PAGE 07 , ,. , , ..1..."lIfl'......._.t~..,.. ,........ :,......_.l..:..'__~........"..;.;.....,/~_:"'.. ~~..~.......~~..;......I""... . . '~.' .'~ ....,1... '_'_at__... ".--. , . .'! . . . l't!I~,.' '. .~,~' JJlI'!.JI'i~' IfJj'.' · i . Jf!Il'. . 'I' ~I;.~J ,Jfil.' . ;Ji 'III"{. t i "'f"j! ',t~. i t .,! ,.,f I .f'l I ,i \. . J JfUJ11 J'. lIt.;! fJifif ~ I' liltli.J .~fl. f:J.ji.!JI. a.;r~li "..~:. . . .' . ,;; ~~ " 111"t ';il'll J II' '.' '. ..' "';,' . .... ....:. :. . .I -I- J. .,1 '. 'I J .. .:. ~ .... ~ ; ':.. ". ....' , .' ,~, ." ';'.. :': . , 21 .! f I' . "111 ~ ) :i. J I, ': ~', ,:". . ('f.:.>..:,. ,:.,'. . ,.~~~;;:.:,':: .::,:::' :' to .fJ .i =,' -il ~ '.' '111". ~: 111" . >.,,~ · ~'.' '. ..~:i:::f:":": ," ':.;. :111. i ll~ :1: I -I' . t; J.. ,. ~,~ .::;. t.. ,'\ . . ~ : u . f J Q Ii J ~ . 1. If It . f ~ '.f 1 , .~.. ~. \SI- ... ~..____c____ 4 Metropolitf ~l Council ~ Working for the Region, Planning for the Future Environmental Services June 7, 2000 Bob Hutchins Building Official City ofPnor Lake 16200 Eagle Creek Ave. Prior Lake, MN 55372-1714 00 ~04(oCf Dear Mr. Hutchins: The Metropolitan Council Environmental Services Division has determined SAC for the Fountain Hills Showroom to be located within the City of Prior Lake. This project should be charged 7 SAC Units, as determined below. SAC Units Charges: Showroom 11944 sq. ft. @ 3000 sq. ft.lSAC Unit Office 2640 sq. ft. @ 2400 sq. ft.lSAC Unit Warehouse 10656 sq. ft. @ 7000 sq. ft.lSAC Unit 3.98 1.10 1.52 Total Charge: 6.60 or 7 If you have any questions, call me at 602-1113. Sincerely, j)). t:..~ j,. . .._.__h ~ Q) (l'jLULJ Cbl. Jodi L. Edwards Staff Specialist Municipal Services Section JLE: (425) 000607S2 cc: S. Selby, MCES Wensmann Builders 230 East Fifth Street St. Paul. Minnesota 55101-1626 (651) 602-1005 Fax 602-1183 TDD/TIY 229-3760 An Equal Opportunity Employer on -04&9 The Cenler of Ihe Lake Counlry White - Building Canary - Engineering Pink - Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT LVQ K'\~( -C:> i \ (\( " APPLICATION RECEIVED -----ff\.o. ZJ .2 O~ I ciOUO The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: Lf 2> $5 S" nS1 N\b n ~ \l\ (J(\ yt ~ E Accepted V Accepted With Corrections Denied t · / ) / Reviewed By: ~(.-uf Date: '112/0<.> Comments: \. t>fZ.o \oJ ,06 t(..,,-u M f M-'ttuN ~b c::te'r CA.l. c.u c..A\~. ~. St:.~re ~(-r? ~E~,) t=o(2.. EAc..l-f Te~ t Ke.c..~, S'P~~" I PLu~"\a ( SEt.U&JL ~... c.,(jA16R- t EL.e:c..1'1L<cA\-.. liThe issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid.1I Thr ('rntrr of thr Lakr Country ~,.,~q ~:j White \ ~Ui~i. C I Canary - Engineering Pink - Planning BUILDING'PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT APPLICATION RECEIVED : ~ \ \,J {,r, '\ ( C:> ;"\(\ \ \ \, (l 1/\ v /) \,. .' \ (\{ . ! .3 O\~ J () 4 ((C( .-") (fO-O o. v' , The Building, Engineering, and Planning Departments have review.. the .uil.in~ lIermit application for construction activity which is proposed at: L I "S (/ S- -C~ \-.,. . I \ \ \ {. l"'\ ~", /: N' E -- 0 1 '''':\ f,r\ I Cl \ () , I i \\.... '\ J l \ 1~ _ ~ Accepted / Accepted With Corrections Denied Reviewed By: ~ O. K~ Comments: Date: fl.1 a1 em · ~ rnu.~ ./)R. IDOJ.:i:d a(') ~ ~d ~ ~/l'VJ uW1J 0/'/00 · [1. LOL.& .k~AYX'~~ .AI11J.l1Addb&nL ~ p~ ~,() \. .A~A /ld - ~~::;~~.A::~ ~-O~~M liThe issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." ~.~~I~. ->> J-ILDERS MORTGAGE COMPANY LLC 646 East River Road Suite #1 Anoka, MN 55303 (763) 323-0820 (763) 323-9105 (Fax) COllstructiOIl l!oall Specialists for Professiollal Builders 14300 Nicollet Ct, Suite 110 BurnsviIle, MN 55306 (952) 898-1110 (952) 892-6555 (Fax) June 13, 2000 City of Prior Lake 4628 Dakota Street SE Prior Lake, MN 55372 IRREVOCABLE LETTER OF CREDIT NO. 5656-600-LS DATED: June 13,2000 Ladies and Gentlemen: We hereby establish our Irrevocable Letter of Credit, numbered as indicated above, and effective immediately for Lot 1, Block 2, Fountain Hills Addition, in favor of the CITY OF PRIOR LAKE (the "Beneficiary") at the request and for the account of WENSCO, INC. a Minnesota corporation (the "Developer") in the amount not to exceed FIFTY THREE THOUSAND EIGHT HUNDRED NINETY ONE AND 001100 DOLLARS ($53,891.00 U.S.), as such amount is decreased as provided below, available to you by your sight draft(s) upon us to guarantee the completion of the Landscape Improvements in connection with that certain Development Agreement between the Beneficiary and the Developer dated , 2000 for Lot 1, Block 2, Fountain Hills Addition. Each draft under this Letter of Credit must be accompanied by: A. The Original of this Letter of Credit; B. A notarized statement executed by the Beneficiary stating the Developer has failed to complete the Landscape Improvements as required under the Developer Agreement referenced above, the Beneficiary is entitled to draw upon the Letter of Credit, and certifying the funds obtained herefrom shall be expended towards completion of the Landscape Improvements. -. .. of Prior Lake .", ~ age 2 IRREVOCABLE LETTER OF CREDIT NO.5656-600-LS DATED: June 13,2000 Each draft under this Letter of Credit must: 1. Be signed on behalf of the Beneficiary by its City Administrator; 2. Bear on its face the clause "DRAWN UNDER LETTER OF CREDIT NO. 5656-600- LS DATED: June 13, 2000. 3. Be presented for payment during regular business hours at our Collection Department, 646 East River Road Suite #1, Anoka, MN 55303 no later than 2PM on June 13, 2001, at which time this Letter of Credit shall expire. The amount of the Letter of Credit shall reduce by the amount of each drawing the amount available under this Letter of Credit. We hereby agree that drafts drawn under and presented in conformity with the terms of this Letter of Credit will be duly honored upon presentation. Facsimile documents on Beneficiary letterhead requesting amendment(s) to this Irrevocable Letter of Credit will be accepted as original documentation by BUILDERS MORTGAGE COMPANY LLC. Except as otherwise expressly stated, this Letter of Credit is subject to the Uniform Customs and Practice for Documentary Credits (1983 Revision). This Letter of Credit shall be deemed to be a contract made under the laws of the State of Minnesota, and as to matters not governed ,by Uniform Customs, shall be governed by and construed in accordance with the laws of the State of Minnesota, including the Uniform Commercial Code as in effect in the State of Minnesota. This Letter of Credit is not transferable or assignable and is not issued for the benefit of any third party claimant. We shall not be called upon to resolve issues of law or fact between the Beneficiary and the Developer. BUILDERS MORTGAGE COMPANY LLC .g; ~ !h~~~ Its Vice President By Thf Cnlff or lhf I..kf Country [)D~OMo1 White - Building Canary~ ~, Engineering Pink - Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT lJJo 1\'1;)(.() " \ (\( APPLICATION RECEIVED -0\0.. () .3 ()-\-\-.1 d arro The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: Lf:5>?s' S- n<)\jY\ ~ n r\1 \\.\ ()(\ yt ~ E Accepted / Accepted With Corrections Denied Reviewed By: tJnerfR fJ..lR.ES#\.f.4NN Date: (pI ~ /00 Comments: T~L. t.J€"s-r G: ~(t" rULE: 0 r: -rn E. AJo (e.:n4 r=t:uv< I tUG> t.. 0\ ;~ 11-( BE. !:SUI L" AS. A /EM..P':>'V':lrt y 'Bl n/Y'1.,t0 0,,)<1 f I.JrtZA rj. C . UNTlt,... rt-lE:. ru~.E fOVNTI4~ )-/iu..s Dfl-loJ E. ) S ).V' ~ 111 L...(... E.D . S'E.6- ltJrp(lM4-:;-\'i>rj 0"; 'HE REJm~E:.. S\OE.. S( E tlJn:\(..H MEND;~. t. ~, .u,!t L ?;n ~ f:)C 11J~PECTi OI\J i J\J f on .t1/f'n ON 2. . Et< 0$. {~I\J Go tJi'""Q Oi M fA Sv,~ ." liThe issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. II STORK@O - "ib9 Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55 If} iJ!r& (651) 645-3601, Fax: (651) 659-7348. - 0'J if 0 {JJ 11 {;II DATE: July 17, 2000A JUL 202000 I!I PROJECT NO.: 030238 By~ Gj -~ TO: Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMIWAREHOUSE PRIOR LAKE, MINNESOTA COpy TO: 1-Wensmann Homes AUn: Tom Sand ~1 COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 1A 1B 1C 10 7-7-00 7-7-00 7-7-00 7-7-00 7 28 28 Hold 3 3 3 3 1.8 1.8 1.8 1.8 Strip footing, Grid lines, (D-E, 8), (E, 4-8), (D.7-E, 4) 3000 3067HM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 01 0480-A 6.00 12.00 28.27 7-10-00 3 4 7-14-00 4:05pm Shear 78940 2790 010480-8 6.00 12.00 28.27 7-10-00 3 25 8-4-00 To Be Tested 010480-C 6.00 12.00 28.27 7-10-00 3 25 8-4-00 To Be Tested ;f~ 1/~~j) TYI~ Nehall Engineering Technician Test results to be reported as they become available. ~ ~ Lee, P.E. Senior Staff Engineer REMARKS: \\ lWINCITIES_NW5\SYS\BMC\2000CME\030238\010480.doc 01 0480-0 6.00 12.00 28.27 7-10-00 3 Hold Hold To 8e Tested Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Kelly Murray DATE: Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 PROJECT NO.: Eagan, MN 55122 July 18, 2000 030238 PROJECT: FOUNTAIN HILLS COpy TO: SHOWROOMIVVAREHOUSE PRIOR LAKE, MINNESOTA 1-Wensmann Homes Attn: Tom Sand 1-City of Prior Lake AUn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 2A 2B 2C 2D 7-11-00 7-11-00 7-11-00 7-11-00 7 28 28 Hold 444 4 1.5 1.5 1.5 1.5 Strip footing, including column pads, Grid lines (C.8-0, 8), (0,7-8), (C.8, 7.2-8) 3000 3067LM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 - Capping 010493-A 6.00 12.00 28.27 7-12-00 1 6 7-18-00 8:10am Shear 98630 3490 010493-B 6.00 12.00 28.27 7-12-00 1 27 8-8-00 To Be Tested 010493-C 6.00 12.00 28.27 7-12-00 1 27 8-8-00 To Be Tested REMARKS: Test results to be reported as they become available. Tyler ehaU Engineering Technician F:\BMC\2000CME\030238\010493.doc 010493-0 6.00 12.00 28.27 7-12-00 1 Hold Hold To Be Tested , f/L ~ Lee, P.E. Senior Staff Engineer Information and statements in this report are derived from material, information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full. without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 -,-2000 15:20 STO A""~ P.02/02 Twin City T t:,...;ting Corporation 662 Cromwen Avenue, Sl Paul, MN SS,,4-1Tl6 (651) 64&-3601. Fax: (651) 659-7348 Kelly Murray l) 'f&\ Wensmann Homes RHS Building 1895 Plaza Drive. Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS SHOWROOMNVAREHOUSe PRIOR LAKE, MINNESOTA TO: DATE: July 17, 2000 PROJECT NO.: 030238 COpy TO: 1';'~~' . . ~ .. ~O!es . 'l.:1'i!!!l1i~ .' ~.., .~i'~ ':,. , .bl.....t"llO. mrSahd t" 1.City of Prior Lak~ Attn: Susan McDermott COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested. days: Slump, In. (ASTM:C143): Air Content. % (ASTM:C231): Location of Placement; Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESUL T~: Laboratory Number. Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & fnroute: Days Lab Cured (ASTM;C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.; Compressive Strength, psI: 1A 18 1C 10 7-7-00 7-7-00 7-7-00 7-7-00 7 28 28 Hold 3 3 3 3 1.8 1.8 1.8 1.8 Strip footing, Grid lines, (O-E, 8). (E. 4-8). (D.7..E, 4) 3000 3067HM Cemstone T. Newhall ASTM:C39 - Compression Test; ASTM:C1231 -- Capping 01048D..A 6.00 12.00 28.27 7.10-00 3 4 7-14-00 4:05pm Shear 78940 2790 010480-8 6.00 12.00 28.27 7-1Q-00 3 25 a~4--00 To Be Tested 01D480-C 6.00 12.00 28.27 7-10-00 3 25 8-4~OO To Be Tested 010480-0 6,00 12.00 28.27 7-10-00 3 Hold Hold To Be Tested REMARKS: Test results to be reported as they become available. $:~~P A Engineering Technician Senior Staff Engineer \\ lWINCITIES_NW5\SYS\BMC\2000cME\Q3DZ38\010480.dac 'nllofmatlctn alld .l.~ In It1l& lint Ifw ttne. Clf the maeriall\1Sl'lll:l or ~ :~ 'tom mal..... lnbrmalicn andr'or ~lIarIe Iurnlah4Id by !he ctJent and ltJU::IUde TIooI. -~"- .,,"" --. ..- ____.... .__.. _... _ _.. . ~ ~~~.ptJfJID.. 01' wie. ThIs tItpI)rt " tho Cgnflds1ltlal Pl'Opf/rty af lL.._t..oj -"lr ~ or frnphd WIIrr1ntia . fa our CUt;lll ..... ItIav nol be IJ.Md fnt ilItflllll'thd"" NIl'nI'I<tao: TOTAL P.02 _.1-2000 17: 28 P.01/02 '1115 PIDA Drive SU'" 220 EIpn, MN 55112 &51.401 ..aa 81.105-'" Fa FAX COVER PAGE TO: ~~ ~ --roM ~o."J. . .' 95l- i../V7 - 4lcJs-' DATE: "'FR.OM: FAX': NUMBER OF PAGES INCLUDING nus COVER LBTrER: Z . SUBJECT: ~lc\,. UJcL~l<<i: + ~.Jbl"^'l L.OC"~~S ~. C~l\ ~. U12- 3~C;- 7~D IF THIS FAX TRANSMrrrAL IS NOT COMPLE1E, PLEASB CALL OUR OffICE AT 651-406-4400. 1HANK YOU!! I _.L-2000 17:28 : ! * r,. Illlil i it ~~ I r _.~._(!J ,-~-i-l f- ,1,LL ~ OO--K n II'r'YY'~m ''''' U I. I I. I" I I I . lUll I I lI'i~~1 z I~~~ i li!2~.. 0 p~i.... i ~Iltl~ ~~~! iiq ~ r: P.02/02 a c~ ~ -0 ;0 ::z: .. "'0lU1,!",,~ !"'~ . .. . norG")'1JR-~!:Q ~~~~~~~;rl -< C025>!::'"tJ OO(f)zz...... r- ", JT1 (')> C) C) ~ U1 > -f:-t ~....__ "'-- ~ TOTAL P. 02 . I I l'IONEER ENGINhERING, P.A. PLEASE RESPOND TO: lEIT~w{ Of TW\NSM~IT Al X 2422 ENTERPRISE DRIVE MENDOTA HEIGHTS, MN 55120 - PHONE: 651-681-1914 FAX: 651-681-9488 625IDGHWAY 10 NE BLAINE, MN 55434 - PHONE: 612-783-1880 FAX: 612-783-1883 CORRESPONDENCE SENT VIA: DATE 1-20-99 I JOB NO. 199601 ATTENTION Kelly Murray RE: Fountain Hills Prior Lake, MN TO: Wensmann Homes x MAIL FAX PAGES INCLUDING TRANSMm AL OTHER ORIGINAL TO FOLLOW COPIES DATE NO. DESCRIPTION 1 MnDOH - Abandoned Well Record - .. . ..... THESE ARE TRANSMITTED AS CHECKED BELOW FOR APPROVAL AS REQUESTED FOR BIDS DUE x FOR YOUR USE REMARKS IF ENCLOSURES ARE NOT AS NOTED, KINDLY NOTIFY US AT ONCE Thank You, d~(#~ Nicholas Polta COPY TO SIGNED .__ I P ....:-. ""'.... I :-._ l:-t .:-t..... ..... 'T' '""'" '1""\ ""'. .......... ... r- I I ,-. ""' _ ~ MDH-WELL MNGMNT UNIT Fax:651-21S-D978 .- . ~.. Sep 15 '99 11:31 STAli OF ~IIIOlTA lEP.nor tF fEALTH AW...... IIU. KECQU J I LaCUl.. fI ~.. c.-II .... P.01 ..1....'saTA UlIQU! weLL., ~ (t.." ,t. t, lie -.) ~ Pr10r Laka ... .....,. .. II. ''r'':- .. \ I...U. 11m ,...'.... R2~W I' U . ne nw 125 ft. .I " ,,"tal Sua, ...." ... Uh If." ....tr. II' '''t.MI ,,. .... .---&1- 9/19/89 ....... It ... 14100 Pike lake Trlil s... tllet lcat1. ., _11 (I. ileUM ,r1~ wlU ~'l .... .,If.ll I..,. ... E J.. I ,~ , ..... le.-_ . . I . ..te . .... . . ., .. .... . . . . E. '.un ....., ... ,,1ft.. IMNn af It"';'C ClIP "..,.,. ....... 1"1..~ .... BRANDT. Dorothy lSSD3 F~ank'in Trat,. SE -- J, AMI'_ LII ...-_ .. I' .., __. l..,ca" ,....li.. 1.. '''' _ _\1 ., ....., ..H. . . post-ir Fax Note To C". Co./Oepl Phone It 7871 ,~~~I ~ -<.{~ .- _ -. rzu IrZm_ 1_ .'Ij,JM (41 .... ~,..... -. 4.I-........-..g.... CJ III1Tw'" (J Ait 0.... 110 ~ ..~ (] .ltete, 0..... I..... I. ~.. .. .11 .........".(.!.J;I . . "tft&t1_ ....)J '" tJ It If IktNl1.... IlAtlIIl at ...... COllet ... k!a. ..Ii... ,.~ 1Ii!r.....t. C] IIP'''':f" ct MM. ..... 10 ImllUII to ....UI: 0 I~'" CJ Tat -" Q "U'..l 10 ~1" lIf'"'I a.. ~..._._ . ~ 't .. WUII(', J[J I'''' 1lJ1- ...4 C Grct' f. (J .,- CI n..,tc CJ nal.',.. ha,1 .; fl. b 1,n r&. 'I. tI oft. t.Z....A...1\ ". lZO". .125 It.. (I' ....J C.... lilt. ..... _ 't. .. _ It. 9/19/89 21. ....uo- ~ 10 ,n,,,, _..r . ~~l ..,..- 11 "' ITC. II. ~ ~TUI }tlJ.., c-l CI...c.tta 0 ...c _IINl eanent ,.,. JLc.~5rt. CII. , <J ~ ....... C A -- bags \ . .uasT suca ,.c 4''''. ;;;-".t.'~ .fen ..u..r,Jil'f.. none "" ,.. .... C ... ....... -,.,-- -c.... ,...... .c, ...... ........- e.... ...-... ~ o c.&r1ftf&' CI ~ I .t. WIT_ ~ aM ...... '....,... . If 1M _,.. ""1.1 fl ...... "&'~..5" tIC'.' ...,........ _\lea) . ~t C Yea jj/W' AM_"~ C T~ C Itl ...lee . 11. U ... CMIIIdOII afr. Tltit _11 ... '.'" ...... ~ Jwr{t~f.ti.. ... 1M' "'"" / fa "- .. 1M -.c .,. ...,_ .. Ml1.,. Schu't~ . ...1:28PM FROM PIONEER ENGINEERING 681 9d88 P.2 . "'**i' .: PID~EER * engln'eering * ~ ... * FAX COVER SHEET CivIl engineers · Land Planners · L.end Surveyors · L.andscape ArchIt8ct& 2422 Enterprise Drive. Mendot8 Heights. Minnesota 55120 DATE: ?,./~ 9' SENT TO:~L' Y M. FAX#: 10 ~ -- ~CQ' 8 FROM: j'J ( L"- ? COMPANY: e.."JC,JSM\~NAJ SUBJECT: Fc)u~nta.-J 'H-'&"c'S PIONEER ENGINEERING, P.A. NUMBER OF PAGES (including cover sheet): L... Please call (651) 681-1914 if you did not receive clear copies or if any pages in the sequence are missing. MEMO: ~e c- c... LrU C- ~Il ~ AJ .,.J:29PM FROM PIONEER ENGINEERING 681 9488 P.3 r. OUTlOT B ".. --- . -' ,- \ / I / I I / I r e....,. .' ~.... -.;....,... I.. ./ -..- -- ,........ '~" I V./ 1ICf IJlIC) I I \ I \ I '\ I "- I ........... ........... ) ........... ' ..:.. of / I I " I ...0 . .) W'!: LL x, " ~--~ 2 '" -- :.NlO OUTLOT A -*- J.l:49a _ ~~:~9: 2000 12: 02 Minnehaha Creek Co 612-781-4198 p. 1 P.e2/B2 ",. an 0' nloaLUCE 1800 I4CtI O~ AYIN'DE 8.& )t1ll0ll LAD. .MII ID72 S..CIAL SDtJCft;-aAJ, 1UTINOYNfD INSIzcnON IC:BEDt1Lt ~~~~ ~(~~~f ~ IPEaAt I11VCfUMl" flmNO MIP DlI1I.C'nDN MaP' AM ,..-.." If-.: ,. II.. .. ,...-...".IIIi.. ., 1&.... ....... . ............ .......... .....,.,.." (1) v. · ~,. UIIt.... nt........., MJT:IIft... s......,..., e._. a) ..... "~J lb. .1....... __,..... .1--'1. . (I) ... -4................ ~maMHI . tMI; ~ ~ ,. ~ ~ ~ ~~ ~. : I 1 -= .,.. l'JIII: - ~ ': if ~ ;;r:;:. Diil ~ 4 ana ~'~.... " \. _ ..T........,... fa lUll IfI! ........ (UtI......." ...11.....) ....... _.... WJI~""" M......., "I -T.III.. .... .....11.. ~. r~ .,.... AIIIIIr '.'.bd- ~!~ A~...... ..........." ~ ,-.... TOTA. fit. 82 mn~r P.R' TOTF:l.. P. 02 June 9, 2000 Commercial Development · Construction ~ 1895 Plaza Drive Suite 220 Eagan, MN 55122 651.406-4400 651.905-3678 Fax City of Prior Lake 16200 Eagle Creek Ave. S .E. Prior Lake, MN 55372-1714 Attn: Robert Hutchins This letter is pertaining additional information that you requested from our June 8th meeting. Item #4 Item #8 Item #16 Item #32 Item #33 Item #34 Item #38 Item #43 Illumination budget calculations will come with our electrical layout plans for you review. Special structural testing form. See attached sheet Exit signs. See 24x36 sheet Siamese Fire Department connection will be located far east closest on our drawings and will be shown on mechanical plans for sprinkler system for your reVIew. Per our plumbing contractor we will need 1" water meter for domestic 1 }'2" water meter for irrigation. Again we will supply you with mechanical plans when done for your review. See attached sheet. We feel these are incorrect gradings listed on our civil plans. We can achieve elevation difference by one landing as sheet shows. Exit doors. See attached 24x36 sheet Hardware information. See attached 24x36 sheet We will need to know the amount for the letter of credit for landscaping. Hopefully this will finish any issues pertaining to this Fountain Hills project and we can pull our permit. Sincerely, ~n#~ -f'~ Thomas J. Sand V.P. Wensco Ilele. johI1s0I1, sheldoI1, sorerl.serl. & ha.fI1er ARCFIITECTS i:nc_ 14525 highway 7 suite 375 minnetonka, mn. 55345 . I el.1 I ph. 612.935.6337 fax 612.935.0878 JSSH PrOject No. OOM009 ADDENDUM NO.2 TO DRAWINGS AND SPECIFICATIONS FOR GENERAL CONSTRUCTION WORK INCLUDING ALL PLillvffiING, HEATING, VENTILATING AND ELECTRICAL WORK PRIOR LAKE FOUNTAIN HILLS SHOW- ROOM/WAREHOUSE PRIOR LAKE, MINNESOTA DATE OF ORIGINAL DRAWINGS AND SPECIFICATIONS: May 5, 2000 Revised: May 10, 2000 DATE OF ADDENDUM NO.1: June 7,2000 DATE OF TIllS ADDENDUM NO.2: June 8, 2000 TO: ALL BIDDERS AND ALL OTHERS WHOM DRAWINGS AND SPECIFICATIONS HAVE BEEN ISSUED BY THE ARCmTECT. TIllS ADDENDUM FORMS A PART OF THE CONTRACT DOCUMENTS. IT SUPPLE- MENTS THEM AND MODIFIES THEM AS FOLLOWS: CHANGES TO THE DRA WINGS AND SPECIFICA nONS Item No.1 Incorporate Revised Drawing AI.I dated 6/8/00 into Construction Documents addressing the following items: (a) Doors 101 to swing toward Showroom 101 (and not as indicated in Addendum No.1). (b) Omission of easterly door at top of stair at Room 201, and omission of westerly door and wall at bottom of stair at Room 101. ( c) Inclusion of exit signs on Drawings. (d) Inclusion of note regarding hardware at fire doors. END OF CHANGES Providing Professional Service to our Clients Since 1972 B5/B8/2BBB 23:B3 952935B878 JSSH ARCHTS INC PAGE Bl . NDILn+ ................... .. , ,. -, ~ ~ ~ - / ,.~ l/6 77.82 \ J- '. , - eo '. .4 . __A ~... - ..... . .. · 4. . .. 1- . ,'.-4._..5 .. G-. . ..~. -. . < .4." . -' ." ~ . - . d . , ."..~ ' -. . . '" . " , n:. J 0' . 4 ".. (86.5). ~ 'f)f.LAJkL~ ~L()ff,/':;}Te:r~'SID,.J FotJ~l-r/1-l tt1t.iss ~~(LaJMj wt\-)"te..Ht>L)$ E rlYO(l LA't-~/M/J. ~/")"D ~~~ ~~.,~,. ~ JUN-09-2000 15:23 P.01/01 , p-:rJILLlAMS L../DANDSCAPE 20200 Otero Ave. Hastings, MN. S&033 437-2827 . A~+f\: ~ 0'0 ''M\..Jkh \h.~ q!5-;).....y~l-y~y '5 WelICOtnc. Tom sand FOI8IbIIn .... Landsc:.. ... Sprlnlcl- ~.... t!StiInate Landscape Trees and slTLbs as LD: 1 PIaI.tng SchedlJe 17f1;J1.75 1 20yc1s.( Hardwood rnJICh,RIver R~ ButT Lmestone ) . 6COl,OO 12 1OX100 EmlBlackpoly 1020,(0 '430' l.a'1c5cape Gride Poly EdrJng 2145.00 Tot..- No fOLR1at1On pIantings on PLP 140 St'v1.tJs to t'ront 26262.75 2376.50 Sprinkler System SpIt1CIer system as Hyti'"oIogiC Plan 15522.20 Plat r ~ power SLWIY.and water meter by others Spt1icIer system FOlJ1datlon plantlngs and Shrlb bedS fronts 12fIJ , r cent. ct1p Ine 4 11!1 valVe kits 4 ,r valve box 1'tNIth COVf!r Total plantng areas 1328.00 zft 53) 8q /. ()() . -...~.... HIII_ 1IA1~/J1RD. TOTAL P.01 June 2,2000 Wensmann Construction Mr. Tom Sands 1895 Plaza Drive Suite 200 Eagan MN 55122 Re: Wensco, Inc. Office/Showroom 4385 Fountain Hills Drive NE Dear Mr. Sands, Following are the results of the preliminary plan review for the Wensco, Inc. Office/Showroom. Our review was based on the Minnesota State Building Code (MSBC) which adopted with amendments the 1997 Uniform Building Code (UBC) with handicap regulations of the Minnesota Accessibility Code Chapter 1341 and with requirements of the 1998 Minnesota State Fire Code (MSFC) which adopted with amendments the 1997 Uniform Fire Code (UFC). The comments are numbered as in the December 19, 1999 r review letter. \to v ~ ~ ~ Submit a soils report. 'S v 6 ~ t 'rlCO, _I / ~rovide the Il1umination Budget Calculation Summary, MN Energy Code Part ~ i' .7670.080. . The proposed warehouses have no occupancy separation provisions to store or drive motorized vehicles into any area. If this is the situation, provide a letter stating that "Motorized vehicles other than electronically driven, will not be driven or stored in the building. " /. Submit Energy Envelope Calculations. b S.A.C. determination must be completed by the Metropolitan Waste Control Commission. Contact Jody Edwards at 651.602.1113. . t>i&Pr-~ Submit the Structural Engineers requirements for Special Inspections UBC 1701.5. See \P-'*'v enclosed. "- At least one of the HDCP parking stalls must be a van HDCP parking stall. MSBC . L 1341..0403 .Su~Part E s~bitem 2. Indicate signage verbiage and location of signs. '6ProvIde eXIt SIgnS at eXIt doors. UBC 1003.2.8.2. ~f? 16200 Eagle Creek Ave. S.E.. Prior Lake, Minnesota 55.372-1714 / Ph. (612) 447-4230 / Fax (612) 447-4245 ."\~; EQi ,\L OPPUTf '.';ITY E\lF'LO',:::R The follo'fing are an additional comments: ~~ ~ \!f:iI-b~ V1TOP\ (2.00('(' \t.~A To r~ w \ vJ ,L.V 2. Indicate location of Siamese Fire Department connection and water meters. 3 Master plumber to calculate water me . e/W~'STHIf> 4 Provide detail of metal and oncrete exterior st irs. nclude rise, run, handrails, and spindles. __ ..Is. Landing at door 127 must be 44: in~~~h. U;c 1003.3.1.7. ~J. Sht CS code review: Compute occupant loads and exiting requirements. Also indicate that Warehouse is an S-I occupancy classification. UBC 311.1 t. Sht AI.I: Locate doors 20 I and 20.2. I _ ~ , '0 ~ I'J 0 a 10 tt'\At.N ._..... \ .,.. AL-r:-8>..v T. C;;,. E.. Lt;.~ I N A: re l.JIfl'. S I" -L. ~ ~ ~tfrO 8 Sht A1.1 Rm. 101: The two required eXIts must be separated over one-half the V(I~~ (>, S.. diagonal measurement of the room. UBC 1004.2.4. JIg. Sht AU: Indicate the use of space under the stairs. UBC 1005.3.3.6. \ v",. ~ Detai19/A3.l: Provide Skylight specifications, materials, etc. li'cv..(i. Sht A4: Indicate Tempered Glass locations. UBC 2406. \/ - / \;2. Detail 8/ A3.l: Handrail height dimension from nose of stair tread. UBC 1003.3.3 .6. Also provide handrail detail at top of stairs MSBC 1341.0434, Subpart 4, Item B. 43 Sht. A4: Identify hardware on Fire-rated doors. Completion of the items is required before issuance of the building permit. The project has received the Cities Development Review Committees (DRC) approval. The City Planning and Engineering plan review comments are forthcoming. Call with any questions at 952.447.9851. Robert. D. Hutchins Building Official Enc. 2 w!cJ!oo 7&-'-" -r S. oN fie; c~ Gcr.lf G.e..w/,Ak:> /Je- (I rL-/-t1VNIN G !f/tS S/~ O~(~ A- t,~ C; r4Z- ~CAhN>-" /~ #-eJO 8,4 M6 ~/;- JM6~ N6tJtJs 7Z> ~w (>C/bVS I ,8~& jJ&z#/I ~/s/C6 IH~ ..u/r. s. cW ~ ~ ./ Llsr 1STf l.,<- ITlfrt S To ~. , ~..~ r~.~:l.... .'5 i)\ il! i d Ii' MAY 3 O. :1; II! ,i f i! Date Received\ .' .. ~'~ Da~)Reviewed -,- ,~_.,., ' -_;v': PE,RMIT REQUIREMENT Date: b / 'I 00 Request: LbL.~~~ Date: Reply: Date: Request: Date: Reply: Date: Request: Date: Reply: Date: Request: Date: Reply: Bu ild ing/P lanning/Eng ineering Permit Complete 0 PERMREQU.DOC 011<56 / Permit # _ REPLY DATE Accept 0 Decline 0 Accept 0 Decline 0 Accept 0 Decline 0 Accept 0 Decline 0 Permit Issued 0 CITY OF PRIOR LAKE 16200 EAGLE CREEK AVENUE S.E. PRIOR LAKE, MN 55372 SPECIAL STRUCTURAL TESTING AND INSPECTION SCHEDULE Project Name Location SPECIAL STRUCTURAL TESTING AND INSPECTION Specification Description Type of Inspector (3) Report Frequency Assigned Section Article Firm (4) Notes: This schedule to be filled out and included in the project specification. Information unavailable at that time, to be filled out when applying for a building permit. (1) Use descriptions per UBC Section 1701, as adopted by Minnesota State Building Code. (2) Special Inspector - Technical, Special Inspector - Strucural. (3) Firm contracted to perform services. ACKNOWLEDGMENTS Each appropriate representative shall sign below: Owner: Firm: Date: Contractor: Firm: Date: Architect: Firm: Date: SER: Firm: Date: SI-S: Firm: \ Date: T A: Firm: Date: SI-T: Firm: Date: T A: Finn: Date: SI- T: Firm: Date: F: Firm: Date: F: Finn: Date: *The individual names of all prospective special inspectors and the work they intend to observe shall be identified. (Use reverse side of form if necessary.) Legend: SER = Structural Engineer of Record SI- T = Special Inspector - Technical SI-S = Speciallnspector - Structural TA = Testing Agency F = Fabricator Accepted for the Building Department by Date SSTI. DOC .J EH3: 41 9529350878 J55H ARCHTS INC PAG~ 01 .---------.... -, ....... Ilele. john.aon.. I!IIheld.on.. soren.sen at har'n..er ARCHXTECTB l:n.c. . I I I 1,.525 highway 7 .un.375 JSSH PrOject No. OOM009 e e mlnnetonk., mn. 55346 . ph. 812.835,8337 felt 812.835.087' ADDENDUM NO.1 TO DRAWINGS AND SPECIFICATIONS FOR GENERAL CONSTRUCTION WORK INCLUDING ALL PLUMBING, HEATING, VENTILATING AND ELECTRICAL WORK PRIOR LAKE FOUNTAIN HILLS SHOW- ROOMIW AREHOUSE PRIOR. LAKE, MINNESOTA DATE OF ORIGINAL DRAWINGS AND SPECIFICATIONS: May S, 2000 Revised: May 10, 2000 DATE OF nus ADDENDUM NO.1: June 7) 2000 TO: ALL BIDDERS AND ALL 01ltER.S WHOM DRAWINGS AND SPECIFICATIONS HAVE BEEN ISSUED BY THE ARCHITECT. TInS ADDENDUM FORMS A PART OF THE CONTRACT DOCUMENTS. IT SUPPLE- :MENTS THEM AND MODIFIES THEM AS FOLLOWS: CIL\NGES TO mE DRAWINGS AND SPEClJ'ICA nONS Item No.1 o.(lSSoils Report is attached. Item No.2 f{ Electrical Subcontractor to provide the lllumination Budget Calculation Summary. Item No.3 L The Developer shall provide a letter stating that "Motorized vehicles other than electronically I driven will not be driven or stored in the building". Item No.4 (p Energy Envelope Calculations are attached. Item No. S 1 The Developer shall provide SAC determination u completed by the Metropolitan W ute Con- trol Commission. Providing Profeeeional Service to our Client. Since 1972 ~ 00:41 9S293Se878 '---......_._""'--~. ----. ...-....-. J5SH ARCHTS INC PAG~ a~ Addendum No. 1 ..2- June 7. 2000 (2 Item No. , " See attached Special Inspections Form as per UBC 1701. S. Jlem No.7 \ \ At handicapped parking area at least one of the stalls must be marked for van parking. The sign- age to indicate van verbiage and location. "em No.8 \ (P The Electrical Contractor to provide Drawings indicating locations of all exit signs at exit doors as well as emergency lighting. Item NOli 9 3 ~ Fire suppression Shop Drawings to indicate location of Siamese' fire department cOMection and location of water meters. . 2.. Item No. 10 ~7 Plumbing Drawings to indicate both calculations and size of water meters. /, k' Item No. 11 '? See attached Drawing detailing both the steel and concrete exterior stairs. Item No. 12 ? ~ At DOQr 127, the landing must be a minimum of44" in length. ~~ Item No. 13 See attached data on the occupant loads and exiting requirements. L.'" Item No. 14 j \ See attached Drawing indicating location of Do on 201 and 202. ~~ Item No. IS Relating to the exiting of Room 101: It is our feeling that we can legally reverse the swing of the doors at pair of Doors 101 and exit through Warehouse Room 107 as an intervening room. ~~ Item No. 16 At Showroom 101, the space below the stairs to the Office Suite 201 shall be totally enclosed and not accessible. Item No. 17 Ao See attached manufacturer's cut on the proposed skylight. Item No. 18 tx. ~ See attached Drawing for locations of tempered glass. ..I 1313:41 ~52935e878 JSSH ARCHTS INC ~A~t:. ~..:l Addendum No. 1 -). June 7, 2000 Item No. 19 See attached Drawing relating to handrail height dimensions at stairs and handrail detail at top of stairs. Item No. 20 Hardware supplier in . Shop Drawing fonnat will identify the hardware on fire rated doors. At a minimum fire rated doon to have a closer, self-latching and be gasketed and if locked during business hours, to have exit devices. Also, aU exterior doors to have thresholds. END OF CHANGES ...~ 66:41 9529356878 JSSH ARCHTS INC PAGE 64 s E; ~ 0- o o n ~ 1R. . 6.". 9'-111 \'! -i z ~ I . . . ~ ~ ~i R~ - ~~ i .- ~I Ilelel .~--:.'''' I _lei lfi:F...:=__ PROJECT FOUNTAIN HILL.S SHOY'tROOM/ ~R.EHaJSE LM PRIOR LAKE, MN ~~ 00:41 9529350878 JSSH ARCHTS INC ''-'I' 11IL . 6."'1- ~ F . ~ ~ . . .;)~. :~..~.; .:. .: , :0.. '. . .. . . s ~ ~ '~'I;' ~ t::1 .... o n ~ ~ ~ ::t: , .. ... la, . .. .' ' '. -, ..~ ..' , .... ".".," . . . .. Ja. . : . fl'- .:': ~ I ~i ~~ ai ~ PAGE a5 ~ 1_-_-1 Iiib~--:'."'" . _lei .~:.T.s_.. PROJECT FOUNTAIN HILLS SHOYiROOM/ ~REH(:)USE PRIOR LAKE, MN LM 2 ~~ 00:41 9529350878 JSSH ARCHTS INC PAGE 66 F.E. 10# ST\.,.. STAIR W/HANORAIL 8- CONe. BLOCK WALl: II R -----t... R. II . II ~ I ft ~ .,..- o PARTIAL FLOOR PLAN 1/8.=1'-0. L8\ ~ OFFI CE 201 II' , 201 202 IN su L. '"' ." i."", ,,~~ LJDN ~ROOF ~ HATCH w6:, D4 ~~ 1 1 , ~ o PARTIAL FLOOR PLAN 1/8-.1'-0. PROJECT 1.-.-1 ~.....a... rCUNTAIN HILLS . .... .~.:r..:==':._ ~~~~~REHOUSE 3 ~a ~~:41 952935~878 JSSH ARCHTS INC PAGE 87 CODe REVIEW APPLICABLE CODES = UBC 1997 A. OCCUPACY CLASSIFICATION OGGUPANGY' - 6ROUP M SALES ROOMS OCCUPANCY - 6ROUP $-1 ~R.EHOU5E NO SEPARATION REGlJIRED BASED ON 90Q.22 OF UBC. E. OCCUPANCY LOADS NO or OCCAJPANTS MIN. REGUIRED ~IDTH PER 1006.29 OF UBG 6RID A-B 6RID B-G cSRID C-E 206 14; 2QS 42" 3011 sqll 1_-_-1 ............... ---..... PROJECT I DATE: . I I .~ :=&11I ~~~~ IO:N e - ... ... - .. PRIOR LAKE, MN LM 4 ~a 88:41 9529358878 JSSH ARCHTS INC r1 I ~ I ~ , ~ , ~ J~ I , I ~ · 0 I . ~~ I ~ ./- I ...., V... , I) ~ . 6.Clf- ~= .~ ~t - . u.~ aiJ IX ~. o '"1t . · iij , ~ ~~ mlp i;t ~ ~ ., il ~ ~~ ~ (21..0 914' I ~ PROJECT 1._._1 .......,~;.. ............ FOUNTAIN HILLS - . .... .~=.:=':._ ~~~,~REHOUSE LM PAl:2t:. t:lO 5 ~a ee:41 952935e878 ~ . 1:'" "= .1 . .... . Ii. ~ . 9 ~ ~ . ~ e'.. .'. ~.. ", .. (2) JSSH ARCHTS INC PAGE 89 \2T.. III 11'-0' 1 1/:.21 1'1" S'T\... ~ AAIL . MU... , . PIu..ED S'Tl... PANS "- Me 12 X 10.6 5T1-. SmlN61:R5 - - - -, STL.eeAM - - - -, AT LANPIMS ---I -----1 ---~ - - - ~ 5TL.. 51lJD --_-.J ~ -__..J I -----, ---I ----t ~ it 9 D ~. .<<.. ....,.. : ,'. ' .. '.' '. ... ., " . . ...~. t.~ STAIR SECTION 3/8" = 1'-0" ~ROJECT FOUNTAIN HILLS SHO~OMI ~REHOU5E LM PR.IOR LAKE MN 6 11-1_1 Mfi-:..... . ........ -JllZ__ ...cJe ee:41 9529350878 JSSH ARCHTS INC PAGE 10 ! .-4' t 1-111' ~... .11 fr ~-- t ~f' .. .. <D mJR mJAL ~ ~ ~ L . ~ ! ... w.... 11 ~~ ... 8 @ @ 8 ~ @) @) ..... - ~ r-f/' (i) r-fl' r__ ~ ~ @) ~~ <!) SIX EQUAL ..,. EC1IOMS ,., _ D()(1R .. ... ..... @) @) @ ~ @) (!) SIX EQUAL V-'NOOW SECllONS AND ON[ DOOR ~ ~ -~ I 8 .S f!l ] @) @ @ :'~ALor:ow ~ @ - INDICA TES TEMpERED GLASS 11_._1 ~--:.a__ . _lei . ~ ...:= _.. PROJECT FOUNTAIN HILLS YiAREHOUSE/ SHO~OM LM PRIOR LAKE MN 1 ~ .... t) = t) a o -n ~ :.; n <r: ~ ~<J~ 66:41 9529356878 en z o t= <( o ::i Q.. Q. ce I! II w OJ)Q) c:.c . .- Co) U2 ~= ::: ::I Q" 0 (I).c- c:_ ~ o 00_ .- ..a - n;...a. .~.E g. Q.rn- Q.,Q 0 l'Q...o ~... 'guni --- oe=S; ;:.Qc: ~Q,"' :J.~ fI) ~ :u g>> C) :;":0 -="'0 0..2 = leiEe's E ... 0I8~- oUe 0~ ,,~:w= ~o >0,. E .z::. -- en._ ~ C2~-- ItIIl ::1._ 0 _:::I . V~ C - ..... _ Q) >"E- ,:'i c '; :c ~ ...~OC~ CD .= .~ ,g U': == C.~~NO~ W~c___... ;; ~.2' G) ; ~ 0) o'1:2.e..oel:c: Ii'll. c ... ,.. c It) '-N v~ ftI CD - ::I ~-~CQo"'O.! "'C.o~.:cC) cu C >. ftI ~'-:' CD :~r; cu:: CD c; a; __.c -e ... .Q.... G) - c,,) ~. .c,,):J~.8 ....=cr:::oE~ -.0"'-' fIG ,c>;:E"Eu ~ftluJoo.oo~ ::::Q)~.2-c,,)O -..........c Q, Q..ftlcn c.- >. :::I en c: Q, >:. c: ~o cn-o_u'" o "6a c,,) C'Q ~ ;; .!:! u._ >.oS - 0';. en-"'O...- ~. "'~o.gEu ~U),g~..c( ~ c CI) ... o E ... .e. CI) ~ CD .c .)C. .~ {) .,... 0.. fJ) U ~ ~ en u rJ) ...J W o o :e N Cl. < ~ N < en ...J w o o ~ N a.. ~ C'I (/) en -J w 8 :; -c- Q.. <I: U ad .,... ~ u en ...J UJ o o ~ JSSH ARCHTS INC -.... ~ ~ I ~ ,5 l.'l ~::I .!!o'e . 0 -_ ~ C !! ~ ~ OJ It'.!! 0 IU ,,- ~!!~ $!a"'~ ~ Q ~ e oII.-.c IU E5 ii ~ Q, c: -~2;~~lDlIJC:""'g~ ~ -e ..2. ~ 1: ~ oS .! '~ ~. ._ E ~::tc:e~I'lI~_iII 8.2 _UO=.c'.'-C-C t:'" ~ ~ ~5 .!at.! J.e i1. '" 8 !. >."C:E~.CIIl",= 1 .c J/C:;,.:I= -.':; IJ. 5P "'-e.ti~~~flt'ftI~:C~ ~ Qle.s _:).. Q,~~",,: o ea~ ~1:i.!! a.g;~:; ~ E::t ~~c>>a Jl-E"'~ ~.. U 2i _ .!! ,x j..a E " ! ~ u$E~~;:;S'5~=5: ~iii~"o.s<.:>~"Og.~III~ ~ .!! l Gi~~ _ ftI _ "= ~~ 0 ~ C",1'lI ..aE e~ c: ~8 ::J~ ~ ~ ~.2:-Q.~ -ed u.!! 1:1 ~ c: ! .c: ..0 iii "0 _ ~ _ .2 E ~ -.;; .... c: ~ c' g Q ~ ,~ III C .. a 2'"' ..- U 4) 41 0 't: - .5...-....=-fti.~t:CJl .I:~c:~,o"'~ac:c8O' .,gt CJl .- - <3 o~ SlI:) -;."0 10 01" ,C'O IIO~ . .e ~ -=~!c:~~i!!,oi'ii: ~ cQle.j~:!ilEl!i1.o"~ ; ~e::JI'lI""~o2= "".!!.. e ;:JU-o;,o--t:: ."O.q IU .s: .. ii .~ e q <<1 : cu E ~ s:; "O.c"llEl.'l 0.. a. - eEeC;:""-jb~EC'O",... III :;J~cvot'O~~OO.eollU ~ uiiot:: uc::.e. _ 0."" WI 1lI lID ~ ~ ~ GI.e . - i ~ 1 D.~ o Oli!!!l e"'E~ ~ u_ ~~.l; c: 1-0 0 0 ~'tJ j's l!-~.e'E at~o.!! ~:i ---i ~ ~ ~ =-,: - E gt.... . ~ t;..2...u<;Ql~~~;J.!e .f=l_ QlD-C;~.! '!iQlC'O 'i .5 "i ~ S .. N .- ~ - QJ - ::s ~ ~ U ii _ 0 B.....;.!! 05 j" ~ IA ;; ..."OIU'" "'-tl --s:; I::tl~!I~E~'2.!- co_ t:'g u:i ~ ~i.n~ Q)~;;:J K~ i! ~:; Ot lUeS . 2 .... ~ u' ): =lClIIc:C: -->>"'C "II Q c: ::J....- lIJ ~Q IJ 0 CD g ::. ~ D .:... 5 ; ~ tW 0. ~.~ ~ 2'~'2 ~~i.!!~ ~.~!'t:l t: ~ I: -ocE-.Q..Q~u.8t: 1( ~ = 3 ~ ~~ -e ~~~:g.r:.g ~;)i c ~'" ~;:J as \] 0'= w o.c:QJ8~s~Q ~1'lI""~o. QJ .r; _ . .~ ili ~ "'5"".!!g~ ~6 QJ._Q,l.Q.o~ Eu_ J:~il'G-';;""- -- AI . 2 ::"' oil 0 ...- .. 01 I'll U'- Ql =':01 Q,l-~>~-=~Q ~~~ -~u" C:Q,c: ~.oc 'Eo.... COO "0 :; -. "0 _ O.!!.- .,;~ e Ql v.!! i ~.e4i F! 41'" 0 .!::! "0 .. ... '-0; ::I L:._ ~ E 0 't: "'~~!~vi';~~8!. ~ 2 W ::t "0 i'tJ <.:) U .e ~1(: OI~. = ,,~~€.~ . =.!::a~'~E,&:tJ:~ C:>>:t~=~e~E'O"O~QJ 5~" :: 't: 0 ::I :: .E 0 ~ - :? E Q1CQI"Ocuo eil)9! ~"O.E.-C;~~ J-= ~:~~~i~~J11=~;: ()s:;:Q1&.l'"':t"'__"'....,,~ ~ ~ NXN 0) 0) U') 'll) I"- X ,..... co lex;:) (0 )(,~ ~ ~ ;::'xa; \.t) co C"oI N .... - ;::'xm U') (,0 U") Ill') \0 X)'O ~ ~ tCixo; "'q" ex:) ~ ~ cOxa; v co :!: ~ tCixcE ~ v r- I\(') MX,,.... I"- 11"- M X ,e') ~ ~ 0><0; M (,0 :!: ~ oxcO M V ~ .:!: 0><0 (""') (""') 'or' .. .... " N><cO N V ..,. .. ;::)(=:: N 0 N ("f') . ..,. :::x:: N N N N 0) 10') ~ )(,~ ~ :!: ~x<E ~ ~ ~ :! -x- :! :! ~ ~ .:;x.q: ~ - CJ') J:~~ ~z_ ~2cn Qwz ~a..~ 0_ o CD en co 0'>> <:> CD o co N ,..., N " U) CD ~ CD co ,... ~ o CD o co CD en N W) CD ..... N It) N &I) N 10 C) CD N ... N .. N ~ co ,... CD ("') N It) co M co C"") CD M C"II &I) GO N CD M co N CD N CD N ~ N ~ N N ." o N CD N <:) N o N o N iI ..J W o o :& . . ... ... t/) ct: o u PAGE 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~ C") - Q. ct N ct: .. D.. 0 < ct: _ 'c.; ~Q: CI) D.. CI) o + t ai E o . "'0 "'0 E ~ .... >- 0- en cu c;; o is . S Q. J! 2 ::J '1:3 cv E o ~ Q, :0 ~ o "0 .2 c Q m c;; en 'in cu "'0 Qj "0 o E .9 o o "0 "0 ~ " " .... ~'~ " ~ ^, " OGl. " "- ~ // ,~ ",1V,r '" "- #1 " ~~.. '" ~ 1/ ',~ '" ~(~, "'" / " ~ " () ~q, ""- / , ,,~ '" ~~r-- ~ / " "'~~, / '~~ ~ '1" '" , ""N "'" X 4. 0 "~i ~~J: ~~v~ i~ 0 ~;;t " ", nR-;Q 2(')~ nc:o ;Q~~ ~~~2 ~~al iC: / // ,/ // ,/ //' ,/ // / // /' < '\ \ \>.\. \ <<\ \ \.:\ \ ~ \\. \ .. \ :::'1 \ ~ \:\ \ ~\ \\ \ \:\ \ l '{\\ \ ~ '\.:\ \ ~\U\\ \:\ \ \,~\ ~ g \\\ \ .." r Z \:~} \ v ,~ \ ~ ~ -1)> r\l\ 0 ~)I \ - \~n~ \ :::0 )> Z t: \ Z F~ \ r 0 I \11, \I~ -0 F 1:-:.. )> (/) \\\\1 \ ::u :: IS: ^ 5 II \~ ~ ~ ~> I 0 I';' '~::I ,----I --i aJ ':;:1 ~ . r WI'II)> () ^ I;:: I o. r\ I ii'H. L_ ~ N ".,........ -I '7t: r ~ :::0 ~L I C ~ :: t.::1 I () J : '1 ::t ---- o G) :::0 )> o - z G) .. .~. .. . ::! . ~ N lOADING DOCK El-882 .. ..... ~.. ~ : .. ':.' ::J . g: N .. '.... .... ';-.. .0.. ........ .._ ..... ;. ;' I ~.; .;. ; ; : :;': ;:', .. .. .. ... ... .. ,: oo. . .. . ... ,. .. .. .. ~.. .. .. ~.. .." .' ... :~ .. ". "." .. t .. .: .. ... .. ... .... . .... - ..~ .. -. .. :. ?: . j ..:::. :.".}:.." / :.} /../: ~ I . ..... ..".. .. .' .. ".." ..... .." .. 1lo. .. .;., ~..... '! ' .. .. ". f'i ". .. .. .......... - 111111'l-l-: ! : !.~ t ~ i~li~tll~~___l~_m II I ~~ tw ~ (;) ~ I ~ ~ (JI ~ ~ H >i1l1iAlMtl!lil!I!r;):;Z: L~'" II I m 00 mO ~ H N II N ". \.\ ... ': "":';;;;~~~t~,~ ~'it;.~... ~'":~:,.., ~'4:l.~ ~.~~!~."!:~--;-..-. ~.-- ..... - '''::' :..~:::::~-: ~ .... :- ~ "':" - -_. - - ~...t. ". ".....~-----~... , - ~~.....:.'-.;........:.!-_.:..~~'L~_..-: 'to.d ll::1l0l A,-rrV'. JDrll 18'1 611 1 to/'t0'd ~~vv t68 etg 12.' ...- ,~.-. -..-.-------- VAN ACCESSABLE 'OJ N~IS snld NOllJ~ . , 6JlullJ() ~Sign Co. .146th st. tUN 55124 891-4444 ss:tt 000e-S0-Nnr _,3-2000 09: 12 jfrrtQ '. 101)\ 1811 RCTION PLUS SIGN CO. I 1211 612 891 4433 P.~l~~l I TOTAL P.01 JUN-06-2000 12:24 TWIN CITY TESTING 651 659 7348 P.02/02 CITY OF llUOa LAKE lSZOO EAGLE CllDK,\ VBNU2 S.E. PRIOR LAkt,'MN 55372 SPECIAL S'BtJcn1UL TESTING AND XNSPEc:nON SCIlEDtTLt =~~~:--/~~~~ 9PEctAt S11t.UCTUM.L rESTING AND lNSP1cnON DlSlftptioa lltpm ttquucy NOIU: 'nil' e to M Id _... ,,,,,,* lie ,~,~ spwdllnliCfB. JafDaucio.l& \IIIt~II1rle It 111. . tat "ft.. ....IIt. "'''iDI for . b.U4lftll'trM!1. (1) 'U.e ......"tiaras J'a' t1It Sect\'b 17Cl. . ",~td by MlMesa. s~ J)uucUaa Co.. (1) SIIeciII WpICItIr- TfdID'~ S,.IA' Wpcear. StNa..1. p) ,.. ..... III perfmB .~., ~aMBNTI riM: -~ 11m: 1LaD: 1 'Q 'Jm1~ .DIU: " fim':' J).It~ en. UMli'YWual_a tJI a "'tltlYlIJlU{aI ill,,*,,", Jfta 011 Wa~ tUy iJ\~4 tel eb..,.e. shall be w..~. (U.. ftWrIt Ii" '" ftuftU III=auy.) . . . tl u.-t sa .,...~ IePRr 'r..... 51-' II s,.ellllNpl&'l.r · Tedftlnl S!-S · 8)IIIiIIw,.tIr. hutNnl fA · t~., A&au:7 ,. FaWJta_ Ac:,.,ted ,..,. Bull"" D.,....... by D.. &Cl1MC TOTAL P.B2 TOTAL P.02 .J2:09P fJ.U~ IIIII1II jDhn~on. sheldon. ~oren~~n & h.fn.,r /,~CHITECT5. Inl:. 1452!:) h~hway 7. ~uttc ~75 mlnn6'tonu. mn 55~ ph: 952.935.6337 fax: 952.935-0676 FAX TRANSMITTAL 5HEEI 10: W .t10~ ~ ' IJ C- Attn: Ttn'1 ?~.D From:: ~ - - ~~ -- Pages including cover: 3 DaU: S .... ~ ,.t:>o Re: ft:v JJ Comment6: 'i~P4.- ~~t ~ 1"he infDmUltion c.ont.lnetA in thle tao.imilc ",.,0.. ie privilcgod and confid.,.,-tial informat.lon inter'llJ~ only for 'the ue~ of the intJiviau.a Of' c:~ na,...,ed .bov.,. If'thc: rcadM of~ie meef).9~ Ie not'thD Intendc:d rcciplc'"t. or the emptoyee or .,c:nt ~.pon~ible 'to deliver jot. '\:() 'the in'toNie.d rc:c:ipic:nt.. you .rel ht:l"eby Mtifica 'toft. any dieeCllmINltior1. dio"t.ribu'tion or copyir19 of thie c:ommun~ if) otrtctay prohibited. ( ) MrtJ t#f"i 1:0 follow ~ nO NarvJ (;opy to follow u2:09P P.oz ENVELOPE COMPLIANCE CERTIFICATE COMcheck Software Version 1.1 Permit # Section 1: PROJECT INFORMATION Checxed by/Date project Information: Name: Fountain Hille Showroom I Warehouse Addr~ss: Prior Lake IndusLrial Park Owner/Agent Lnformation: Name: wensco Inc. Tel: GSl-406-4400 Document Author Information: Name: Lubor Manolov Tel: 952-935-6337 Date: 5-3-00 Section 2: GENERAL lNFORMATION Building Location: Climate Zone: 16 Heating Degree Days Cooling Degree Days Building Type: Scott, Minnesota (base 65 degrees F) : (base'S degrees F) : Retail/Wholesale 8618 44') Floor Area: 323~4 Project Description: New Construction Addition Alteration Uncondi~ioned Shell (File Affidavit) Section 3: REQUIREMENTS CHECKLIST AIR LEAKAGE, COMPONENT CER~IFICATION, AND VAPOR RETARDF.R REQUIREMENTS InspeCLion Approved InitLal Date (y IN) All joints and penetrations are caulked, gasketed. weather-stripped. or o~herwise eealed windows. doore, and skylights cQrtified as meeting leakage requirements Component R-values ~ U-factore labeled as certified Vapor retarders installed Exception: Zonee 2-7 in exempted states 02:09P P.03 CLIMATE-SPECIFIC REQUIREMENTS - - - - - - - - - .' - - - - - ., - - - - - - - - - - - - - - - - - - - - - - - - - - - . - - - - - - .. - - - - - - - -' - - - - - - - ~ - - - - - - - .. - - - - component. Name/oescr:i.pt.ion Cavity Cont. Assembly Budget Area R-Value R-Value U-Fact.or U-Fact.or - - - - - - - - - - - " - - - - - - . - - - - - - - - - - - - - - - - - - - - _. - - - - - - - .. - - - - - - - .. - - - - - - - .. - - - - - - - .' - - - - - - ROOF: Nonwood Joist/Truss 29300 0.0 24.0 0.040 o . 046 WALL: CMU >8"/Int. Ins 276'- 6.6 0.097 0.067 WALL: CMU >811/Empty Ce11/Mtl 2126 2.3 10.0 0.069 0.067 WALL: CMU >B" /Empty Cell/Mt.l 44~ 2.3 38.0 0.024 0.067 WALL: CMU <~8"/Empty Cell/Mtl 1232 2.1 10.0 0.071 0.067 WALL: CMU <=8"/Empty Cell/Mt1 894 2.1 38.0 0.024 0.067 WALL: CMU <=811/Int. Ins 6056 4.1 0.144 0.067 WALL: CMU <=8"/~mpty Cell/Mtl 1474 2.1 10.0 0.071 0.067 WAI~L : Metal Frame, 16" a.c. 828 19.0- 0.6 0.107 0.067 WIN: Low-E/Clr/Tbrk/SHGC=0.71/PF~0 2763 0.570* SKY: KALWALI../SHGC=0.02, prop shgc = 0.0 128 0.046* DOOR: Opa.que 324 0.700- DOOR: Glafls 230 0.920* SLAB: Unheat.ed '11/36" Vertical 97'). 10.0 Note: .. indica~cs the entry is a COMcheck default - - - . . - - - - - - - .. - - - - - - - - . - - - - - - - - - - - - - - - - - - .r" - - - - _ _ _ _ _" - - - - - - - - - . - - - - - - - - - - . - - - - - -- Envelope Pk~SES: Design 8~ better than code Section 4: COMPLIANCE STATEMENT The proposed envelope design repreeent.ed in these document.s is consist.ent with the building plans, specifications and other calculations submitted with ~his permit application. The proposed envelope system has been designed to meAt the COMcheck-MN VerAion 1.1 requirements. principal Envelope nesigner-Name Signat.ure Dat.e ~F-.~~ ~~ johJuJon. Sheldon, So~~ ARCHITECTS, Inc. 14525 Highway 7 Suite 375 Minnetonka, MN 55345 sj~ Notes: City of Prior Lake 16200 Eagle Creek Ave. SE Prior Lake, MN 55372-1714 Attn: Robert Hutchins Pertaining to item #5 from your letter dated December 19, 1999, Only electronically driven fork lifts will be used at Fountain Hills Drive warehouses. ^ 4!105' -r:S (p ~ 8-00 Sincerely, , I /) ~~J f'~ Thomas J. Sand V.P. Wensco Inc. 1895 Plaza Drive Suite 220 Eagan, MN 55122 651.406~4400 651.905~3678 Fax . STOFlK@ Twin City (esting Corporation TO: Ms. Kelly Murray Wensmann Homes, Inc. RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: January 6,2000 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS - WENSMANN HOMES PRIOR LAKE, MINNESOTA SOIL OBSERVATION AND TESTING INTRODUCTION: This report presents the results of our observation and testing of the soils within Wensmann's Fountain Hills Lot Development project in Prior Lake, Minnesota. Our work in the field was authorized by Wensmann Homes on August 23, 1999. Our scope of services was limited to the following: 1. Observe the soils exposed within the mass excavation for the proposed structures on an intermittent basis. 2. Perform shallow hand auger borings to aid in judging the localized subsurface soil conditions. 3. Document that the soils exposed in the excavation bottom correspond to the conditions discussed in the geotechnical report for the project (Maxim Project No. 9754408). 4. Judge whether the exposed soils are suitable for support of the anticipated fill and/or building loads. 5. Perform intermittent compaction testing of fill soils placed to establish final grades. 6. Perform intermittent testing of site concrete placements (curb and gutter) on Fountain Hills Drive and Fountain Hills Court. 7. Observe placement of the bituminous pavement and obtain samples for laboratory testing to document aggregate gradation and asphalt content of the paving mixture. Information and statements in this report are derived from material. information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. ThiS report shall not be reproduced except In full. Without written approval of this laboratory. The recording of false. fictitious or fraudulent statements or entries on this document may be pUnished as a felony under Federal Statutes including Federal Law Title 18. Chapter 47 PROJECT NO: 9909463 PAGE: 2 CONCLUSIONS: Based on our observations and hand auger borings, it is our opinion the soils exposed within the completed excavations for the proposed structures consisted of naturally deposited sandy lean clays and clayey sands. The strength or apparent density of the observed soils agreed, in our judgement, with that depicted by the preconstruction test borings performed for the project by Maxim Technologies. Therefore, these soils were judged suitable for support of the anticipated fill and foundation loadings of 2000 psf for Block 1, Lot 2 and to 2500 psf for Block 1, Lot 1; Block 2, Lot 1. PROJECT INFORMATION: The site is located just west of Pike Lake Trail and just south of County Road 42 in Prior Lake, MN. At this time we' have little or no information in regards to the structures planned for this site. Building size and location have not been determined. However through conversations with you we have been informed a gas station will be placed on Block 1, Lot 2. We have also been informed the remainder of the site will include commercial office and industrial buildings. Typically, these buildings will be high, 1-story, slab-on-grade structures. We estimate these buildings will have column loads on the order of 100 kips and wall loads of about 5 kips per lineal foot. Floor slab loads may be on the order of 250 pounds per square foot. We further understand the footings will be placed to provide normal frost protection depth. The footings should be designed to exert a net allowable soil bearing pressure of 2000 pounds per square foot (psf) for the gas station on Block 1, Lot 2 and 2500 psf for the remaining commercial office and industrial building's lots. During our observations, we had access to the report of the preconstruction soil boring program performed at the site by Maxim Technologies, project No. 9754408. Maxim Technologies report indicated the generalized soil profile consisted of primarily natural clayey glacial till throughout the site. At some locations there is uncontrolled fill, organic topsoil and or very soft clayey soils at the surface. Based on the penetration resistances (N values) the native clay till are very soft to firm in consistency. According to the report, site preparation should consist of removing the surface vegetation, topsoil, fill, and very soft clays from the building pad areas to expose the competent soils. The underlying stiffer native clays should be suitable for building footing support. Please refer to the referenced reports for specific details. OBSERVATION METHODS AND RESULTS: Between August 1999 and November 1999, our firm observed the soils exposed during the excavation for Wensmann's Fountain Hills Development, on an intermittent basis. In Information and statements in this report are derived from material, Information and/or specifications furnished by the client and exclude any expressed or Implied warranties as to the fitness of the matenaltested or analyzed for any particular purpose or use. This report IS the confidential property of our client and may not be used for advertiSing purposes ThiS report shall not be reproduced except In full, Without wfllten approval of this laboratory The recording of false. fictitious or fraudulent statements or entfles on thiS document may be punished as a felony under Federal Statutes Including Federal Law Tille 18, Chapter .t 7 PROJECT NO: 9909463 PAGE: 3 addition to observing the exposed soils, we placed several shallow (3%') hand auger borings into the subgrade at the bottom of the excavations. The observed soils and those retrieved by our shallow hand auger borings were visually and manually classified in general accordance with ASTM: 02488, and estimates were made of their strength properties. The excavations were performed with large scrapers, backhoes, and/or bulldozers. The excavation generally consisted of stripping the top l' to 4' of topsoil/fill, removing the very soft clays from the proposed building areas and then placing engineered fill where necessary. Where the non-organic portions of the old fill was removed, it was then replaced as compacted fill to specification requirements. .. The exposed soils, in the observed areas, were judged to consist of sandy lean clays and clayey sands with various amounts of gravel. The sandy lean clays were of soft to firm consistency and the clayey sands were loose to medium dense, based ,on the resistance estimated by our hand auger probes. The observed soils appear suitable for support of the fill and structural loading. Based on staking provided by the contractor and the project surveyor at the time of our observations, the excavations, where' applicable, appeared to extend to the building pad boundary lines. Since no information was available as to the location of the buildings being placed on the building pads it is impossible to determine if oversize requirements have been met for the foundation systems of the buildings. We strongly recommend an engineering review once the locations of the buildings have been determined. This review will need to assure that satisfactory 1: 1 lateral oversizing for the buildings has been met. This oversizing is necessary for the lateral distribution of the foundation loads throughout the fill sequence. COMPACTION TESTING: Ninety-two (92) soil density tests were performed within compacted fill placed to establish the planned finish subgrades, on an intermittent basis. The density tests were evaluated according to the Moisture Density Relation of Soil as designated by ASTM: 0698-91 (Standard Proctor). The results of the tests, which are attached, indicate the recommended compaction level of 950k was attained for the building pad areas. CONCRETE TESTING: Attached are plastic daily sheets documenting testing and sampling of plastic concrete on October 25, 1999. Our engineering technicians performed tests for slump of the concrete mixture (ASTM C: 143), tests for air content of freshly mixed concrete by pressure method (ASTM C:231), measured the temperature of the concrete, and cast the necessary concrete cylinders for the purpose of compressive strength testing. The results of our field testing of plastic concrete are shown on the attached daily report form. This report also Informallon and statements In this report are derived from material. Informallon and/or specifications furnished by the client and exclude any expressed or Implied warranties as to the fitness of the matenal tested or analyzed for any particular purpose or use. This report IS the confidenllal property of our client and may not be used for advertising purposes This report shall not be reproduced except In full. without written approval of this laboratory The recording of false. fictitious or fraudulent statements or entnes on this document may be plJrlIshed as a felony under Federal Statutes including Federal Law Title t B. Chapter 47 PROJECT NO: 9909463 PAGE: 4 indicates the concrete mix design, the concrete supplier, the location of concrete placement, and the method of concrete placed. Concrete test cylinders were temporarily stored at the project, and then submitted to our laboratory for moist curing and compressive strength testing. The results of our compressive strength testing are also attached. DRAINAGE CONSIDERATIONS During construction, surface water should be controlled by maintaining positive surface drainage away from the building pads at all times. The observed groundwater level in the soil borings depends on normal variations in precipitation and surface runoff amounts. However, based on the water level measurements and on the soil profile, it is our judgement that the subsurface water at this site exists at a depth that is not anticipated to present construction difficulties for a project of this type. REMARKS: It must be recognized that we do not practice in the field of surveying. Therefore, we must rely on elevation and location information provided by others. If the construction is redesigned or otherwise moved subsequent to our work, we should be informed so our firm can assess if additional engineering observation is required or suggest engineering alternatives. Should you have any questions or if we can be of further service, please do not hesitate to contact us at (651) 659-7447. STORK TWIN CITY TESTING CORPORATION Revi~CW..,Y0 ~J n/~ Leonard A. Rasmussen, P.E. Senior Geotechnical Engineer Attachments: 1-Density Tests of Compacted Fill Building Pads and Streets #1-#92 (30 pages) 1-Moisture Density Curves #1-#4 (4 pages) 1-Mechanical Analysis of Soil #1-#6 (4 pages) 1-Tests of Plastic Concrete (1 page) 1-Compression Tests of Concrete Cylinders (2 pages) 1-Asphalt Concrete Mixture Testing (2 pages) cc: 1-Susan McDermotUCity of Prior Lake 1-Nathan AdamslEnebak Construction 1-Nick Polta/Pioneer Engineering InformatIOn and statements In thiS report are derived from material. information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the htness of the matenal tested or analyzed for any particular purpose or use. This report IS the confidential property of our client and may not be used lor advertising purposes. ThiS report shall not be reproduced except In full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entnes on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 :STOA~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: September 2, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 1 2 DATE TAKEN: BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 8-30-99 8-30-99 Sandy lean clay Sandy lean clay with a little with a little gravel, brown, gravel, brown, (CL)-1 (CL)-1 Fountain Hills Fountain Hills Court, Sta 2+00, Court, Sta 2+75, 8'Left of 9'Left of cel1terline centerline 3' 3.5' 1 ' l' UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 104 93 Moisture Content (%) 17.3 21.4 Plus #4 Material (%) 6 8 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 112.1 112.1 Optimum Moisture (%) 15.8 15.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 92.5 95 83 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made a 0 the adequacy of fill and compaction at locations and elevations other t thos ested These tests were performed by M. Straightffwin City Testing. REVIEWED BY: F :\BMC\9909483\d 1-2.doc ~TOA~@) Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATe: September 7, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 3 4 5 DATE TAKEN: 9-1-99 9-1-99 9-1-99 UNIFIED SOILCLASSIFICA TION: Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-1 (CL)-1 (CL)-1 LOCATION: Retest #1, Retest #2, Fountain Hill Fountain Hill Fountain Hill Court, Sta 4+10, Court, Sta 2+00, Court, Sta 2+75, 10' left of 8' left of 9' left of centerline centerline centerline BELOW SUBGRADE: 2.5' 3.5' 8' DEPTH BELOW EXISTING GRADE: 1.5' 1.5' 1.5' FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 110 112.5 113 Moisture Content (%) 16.1 15.2 15.0 Plus #4 Material (%) 3 7 7 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "An, (-#4 Basis) Maximum Dry Density (pcf) 112.1 112.1 112.1 Optimum Moisture (%) 15.8 15.8 15.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 98 95 100.5 95 101 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made a to the adequacy of fill and compaction at locations and elevations other t th e ested. hese tests were performed by M. LemkelTwin City Testing. REVIEWED BY: Pro F:\BMC\99CME\9909463\d3-6.doc STOA~@) Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: September 14,1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 6 7 DATE TAKEN: BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 9-2-99 9-2-99 Sandy lean clay Sandy lean clay with a little with a little gravel, brown, gravel, brown, (CL)-1 (CL)-1 Fountain Hill Fountain Hill Court, Sta 3+50, Court, Sta 4+50, 1 O'Left 10'Left 4' 5%' l' l' UNIFIED SOILCLASSIFICATION: (Moisture-Density Sample Number), LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 112 110 Moisture Content (%) 15.1 16.1 Plus #4 Material (%) 3 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "An, (-#4 Basis) Maximum Dry Density (pcf) 112.1 112.1 Optimum Moisture (%) 15.8 15.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 100 95 98 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made to the adequacy of fill and compaction at locations and elevations other t t s test . These tests were perfonned by M. LemkefTwin City Testing. REVIEWED BY: STOR~@ Twin City Testing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 DATE: September 14, 1999 PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 8 9 DATE TAKEN: 9-3-99 9-3-99 UNIFIED SOILCLASSIFICA TION: Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little gravel, brown, gravel, brown, (CL)-1 (CL)-1 LOCATION: Fountain Hill Fountain Hill Court, Sta 4+85, Court, Sta 3+25, 8'Left 8'Left BELOW SUBGRADE: 3' . 3' DEPTH BELOW EXISTING GRADE: 1 ' 1 ' FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 111 109 Moisture Content (%) 15.7 16.1 Plus #4 Material (%) 3 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "An, (-#4 Basis) Maximum Dry Density (pcf) 112.1 112.1 Optimum Moisture (%) 15.8 15.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 99 95 97 95 Density tests are valid at the location and elevation of the test only. No representation is made a to the dequacy of fill and compaction at locations and elevations other than th teste. hese tests were performed by M. LemkelTwin City Testing. REMARKS: REVIEWED BY: STORK@ Twin City Testing Corporation 662 Cromwell Avenue, 51. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: September 14, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 10 11 12 DATE TAKEN: UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number). BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 9-9-99 9-9-99 9-9-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-1 (CL)-1 (CL)-1 Fountain Hill Fountain Hill Fountain Hill Drive, Sta 3+50, Drive, Sta 2+75, Drive, Sta 1 +00, Centerline 1 O'Left Centerline 5' 3' 3' 2' 1 ' 1 ' LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 112 112 111 Moisture Content (%) 14.8 14.0 13.9 Plus #4 Material (%) 3 5 5 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 112.1 112.1 112.1 Optimum Moisture (%) 15.8 15.8 15.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 100 95 100 95 99 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as to the adequacy of fill and compadion at locations and elevations other tha tho ested. hese tests were performed by M. LemkelTwin City Testing. REVIEWED BY: Proj F:\BMC\99CME\9909463\d10-12.doc STOR~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: September 14,1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 13 14 ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 9-10-99 9-10-99 Sandy lean clay Sandy lean clay with a little with a little gravel, brown, gravel, brown, (CL)-1 (CL)-1 Block 1, Lot 2, Block 1, Lot 2, 120'5 & 80W of 120'5 & 140W NE property line of NE property corner line corner 849 851 6" 6" DATE TAKEN: UNIFIED SOILCLASSIFICATION: (Moisture-Density Sample Number) LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 113 112 Moisture Content (%) 14.1 13.6 Plus #4 Material (%) 3 4 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 112.1 112.1 Optimum Moisture (%) 15.8 15.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 101 95 100 95 Density tests are valid at the location and elevation of the test only. No representation is made as the adequacy of fill and compaction at locations and elevations other tha thos sted. hese tests were performed by M. LemkelTwin City Testing. REMARKS: REVIEWED BY: STOR~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: September 14,1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 15 16 17 DATE TAKEN: UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) LOCATION: ELEVATION OF TEST: (feet) BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 112 113 112 Moisture Content (%) 14.6 13.1 14.2 Plus #4 Material (%) LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "Art, (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 112.1 Optimum Moisture (%) 16.1 16.1 15.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 99 95 100 95 100 100 Density tests are valid at the location and elevation of the test only. No representation is made a to the adequacy of fill and compaction at locations and elevations other t thos t ted. Th e tests were perfonned by M. LemkelTwin City Testing. REMARKS: REVIEWED BY: STOA~~ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA DATE: October 4, 1999 PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 18 19 20 DATE TAKEN: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 9-13-99 9-13-99 9-14-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 Phase 2, 150'N Phase 2, 100'N Phase 2, 160'N & 75'E of NW & 70'E of NW & 80'E of NW pond structure pond structure pond structure 846 848 850 l' 1 ' l' UNIFIED SOILCLASSIFICATION: (Moisture-Density Sample Number) LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 112 109 110.5 Moisture Content (%) 16.6 15.8 14.7 Plus #4 Material (%) 6 6 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 113.1 Optimum Moisture (%) 16.1 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 99 95 96.5 95 97.5 95 Density tests are valid at the location and elevation of the test only. No representation is made as to he adequacy of fill and compaction at locations and elevations other th n those e ted. Th e tests re performed by M. LemkefTwin City Testing. REMARKS: REVIEWED BY: siORK@ Twin CllY Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 DATE: October 4,1999 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS PRIOR LAKE, MINNESOTA PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott PROJECT: TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 21 22 23 DATE TAKEN: 9-15-99 9-15-99 9-15-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 Phase 2, 220'N Phase 2, 180'N Phase 2, 120'N & 100'E of NW & 75'E of NW & 70'E of NW pond structure pond structure pond structure 851' 853 852 l' l' 1 ' UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) LOCATION: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 107.5 111 Moisture Content (%) 14.9 15.3 Plus #4 Material (%) 3 6 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 110 16.4 6 Method ASTM:D698-91, Procedure uA", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 Compaction Specified Compaction (%) (%) 95 95 98 95 97 95 24 9-15-99 Sand lean clay with a little gravel, brown, (CL)-3 Phase 2, 75'N & 70'E of NW pond structure 854 1 ' 110 15.1 6 113.1 16.1 97 95 Density te s are valid at the location and elevation of the test only. No representation to the equacy of fill and compaction at locations and elevations other ested. T ere perfonned by M. LemkelTwin City Testing. REMARKS: REVIEWED BY: ~TO R I...ti~ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: DATE: October 4, 1999 Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 25 26 27 DATE TAKEN: UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) 9-16-99 9-16-99 9-16-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 Phase 2, 210'N Phase 2, 175'N Phase 2, 130'N & 140'E of NW & 100'E of NW & 80'E of NW pond structure pond structure pond structure 853 853 854 l' l' l' LOCATION: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 113 111 Moisture Content (%) 15.7 15.1 Plus #4 Material (%) 6 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 112.5 14.7 6 Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 Compaction Specified Compaction (%) (%) 100 95 98 95 99.5 95 28 9-16-99 Sand lean clay with a little gravel, brown, (CL)-3 Phase 2, 50'N & 80'E of NW pond structure 856 l' 112 14.3 3 113.1 16.1 99 95 Density tests are valid at the location and elevation of the test only. No representation is made as t the adequacy of fill and compaction at locations and elevations other th thos t sted. Th e tests were performed by M. Lemkerrwin City Testing. REMARKS: REVIEWED BY: .:ITO AK@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: September 22, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 29 DATE TAKEN: 9-17-99 UNIFIED SOILCLASSIFICATION: (Moisture-Density Sample Number). Sandy lean clay with a little gravel, brown, (CL)-3 LOCATION: Phase I, 150'S & 50'E of NW pond structure BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 20' 6" Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 113.5 Moisture Content (%) 12.8 Plus #4 Material (%) 6 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.1 Optimum Moisture (%) 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 100.5 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as to t e adequacy of fill and compaction at locations and elevations other th n t e teste T were performed by M. Straightrrwin City Testing. REVIEWED BY: ~TOR~@ Twin City Testing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 DATE: October 4, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 30 31 32 DATE TAKEN: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 9-20-99 9-20-99 9-20-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 Phase 2, 50'S & Phase 2, 90'N & Phase 2, 210'N 110'E of NW 75'E of NW pond & 140'E of ~ pond structure structure pond structure 859 857 856 l' 1 ' l' UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 113 111 115 Moisture Content (%) 15.1 11.8 11.2 Plus #4 Material (%) 8 6 8 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure uA", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 113.1 Optimum Moisture (%) 16.1 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 100 95 98 95 102 95 REMARKS: are valid at the location and elevation of the test only. No representation is made as t the ade uacy of fill and compaction at locations and elevations other than ose e ted. ests were performed by M. LemkefTwin City Testing. REVIEWED BY: Project F:\BMC\99CME\9909463\d30-32.doc .6TOA~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 4, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 33 34 35 DATE TAKEN: 9-22-99 9-22-99 9-22-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 Phase 2, 50'N & Phase 2, 150'N Phase 2, 200'N 100'E of NW & 100'E of NW & 120'E of NW pond structure pond structure pond structure 860 858 858 1 ' 1 ' l' UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) LOCATION: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 114 112 Moisture Content (%) 10.6 11.1 Plus #4 Material (%) 10 5 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 113 11.9 5 Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 Compaction Specified Compaction (%) (%) 99 95 100 95 101 95 REMARKS: 36 9-22-99 Sandy lean clay with a little gravel, brown, (CL)-3 Phase 2, 11 O'N & 140'E of NW pond structure 860 l' 113 12.1 8 113.1 16.1 100 95 Density tests are valid at the location and elevation of the test only. No representation is made as 0 the adequacy of fill and compaction at locations and elevations other t a thos sted. T ese tests were performed by M. LemkelTwin City Testing. REVIEWED BY: '=;TOR~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 4, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 37 38 39 DATE TAKEN: 9-24-99 9-24-99 9-24-99 UNIFIED SOILCLASSIFICA TION: Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 LOCATION: Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, 175'S & 140'E of 225'S & 140'E of 180'S & 160'N of NW property NW property NW property comer comer comer ELEVATION OF TEST: (feet) 856 853 857 DEPTH BELOW EXISTING GRADE: 1 ' l' l' FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 110.5 109 112 Moisture Content (%) 10.9 12.7 10.1 Plus #4 Material (%) 3 3 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "An, (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 113.1 Optimum Moisture (%) 16.1 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 98 95 96 95 99 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation dequacy of fill and compaction at locations and elevations other ests were performed by M. LemkelTwin City Testing. REVIEWED BY: :iTOAM@) Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 4, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 40 41 42 43 DATE TAKEN: 9-27-99 9-27-99 9-27 -99 9-27-99 UNIFIED SOILCLASSIFICA TION: Sandy lean clay Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 (CL)-3 LOCATION: Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, 175'S & 150'E of 180'8 & 150'E of 170'S & 260'E of 180'8 & 262'E of NW property NW property NW property NW property corner corner comer corner ELEVATION OF TEST: (feet) 859 861 860 862 DEPTH BELOW EXISTING GRADE: 2.5' 6" 2.5' 6" FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 109 108.5 Moisture Content (%) 13.8 13.1 Plus #4 Material (%) 3 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 112 12.7 3 112 12.7 8 Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 113.1 16.1 Compaction Specified Compaction (%) (%) 96.5 95 96 95 99 95 99 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made a to the adequacy of fill and compaction at locations and elevations other tha tho tested These tests were performed by M. LemkelTwin City Testing. REVIEWED BY: STOA~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 4,1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polla 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 44 45 DATE TAKEN: 9-27-99 9-27 -99 UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) Sandy lean clay with a little gravel, brown, (CL)-3 Sandy lean clay with a little gravel, brown, (CL)-3 LOCATION: Block 1, Lot 1, Block 1, Lot 1, 270'S & 180'E of 275'S & 180'E of NW property NW property corper corner ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 862 2.5' 864 6" Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 112.5 112 Moisture Content (%) 12.5 13.1 Plus #4 Material (%) 8 8 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pct) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 99.5 95 99 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as to the adequacy of fill and compaction at locations and elevations other than hose d. The tests were perfonned by M. LemkelTwin City Testing. REVIEWED BY: roje F:\BMC\99CME\9909463\d44-t6.doc STOR~@ Twin GILY Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 4, 1999 PROjECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 46 47 48 49 DATE TAKEN: 9-28-99 9-28-99 9-28-99 9-28-99 UNIFIED SOILCLASSIFICA TION: Sandy lean clay Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 (CL)-3 LOCATION: Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, 150'5 & 160'E of 155'S & 162'E of 140'S & 280'E of 250'S & 175'E of NW property NW property NW property NW property comer comer comer comer ELEVATION OF TEST: (feet) 863 865 866 866 DEPTH BELOW EXISTING GRADE: 2.5' 6" l' l' FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 108.5 110 Moisture Content (%) 11.3 11.9 Plus #4 Material (%) 3 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 112 11.8 5 112.5 12.1 5 Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 113.1 16.1 Compaction Specified Compaction (%) (%) 96 95 97 95 99 95 99.5 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as the adequacy of fill and compaction at locations and elevations other th thos ested. ese tests were performed by M. LemkelTwin City Testing. REVIEWED BY: Pro ct Manager F:\BMC\99CME\9909463\d46-49.doc STOA~(!) Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA DATE: October 4, 1999 PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 50 51 52 53 DATE TAKEN: 9-29-99 9-29-99 9-29-99 9-29-99 UNIFIED SOILCLASSIFICATION: Sandy lean clay Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 (CL)-3 LOCATION: Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, 240'S & 160'E of 234'S & 156'E of 125'S & 300'E of 128'S & 298'E of . NW property NW property NW property NW property corner comer comer comer ELEVATION OF TEST: (feet) 868 870 867 869 DEPTH BELOW EXISTING GRADE: 2.5' 6" 2.5' 6" FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 113.5 112.5 Moisture Content (%) 12.6 11.3 Plus #4 Material (%) 8 6 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 112 10.2 6 113 11.5 8 Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 113.1 16.1 Compaction Specified Compaction (%) (%) 100.5 95 99.5 95 99 95 100 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as 0 the adequacy of fill and compaction at locations and elevations other t tho e ested. hese tests were performed by M. LemkelTwin City Testing. REVIEWED BY: STOA~@ Twin CII.Y Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 4,1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 54 55 56 57 DATE TAKEN: 9-30-99 9-30-99 9-30-99 9-30-99 UNIFIED SOILCLASSIFICA TION: Sandy lean clay Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 (CL)-3 LOCATION: Block 1, Lot 1 , Block 1, Lot 1, Block 1, Lot 1, Block 1, Lot 1, 170'8 & 275'E 166'8 & 272'E of 230'S & 155'E of 225'8 & 160'E of of NW property NW property NW property NW property corner comer corner comer ELEVATION OF TEST: (feet) 870 872 870 872 DEPTH BELOW EXISTING GRADE: 2.5' 6n 2.5' 6n FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pct) 110 115 Moisture Content (%) 12.1 12.9 Plus #4 Material (%) 5 10 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 113 13.7 8 113 11.1 5 Method ASTM:D698-91 , Procedure "An, (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 113.1 16.1 Compaction Specified Compaction (%) (%) 97 95 101.5 95 100 95 100 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as t the adequacy of fill and compaction at locations and elevations other th thos t sted. T ese tests were perfollTled by M. LemkelTwin City Testing. REVIEWED BY: STOAK@) Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 6, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 58 59 ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 10-1-99 10-1-99 Sandy lean clay Sandy lean clay with a little with a little gravel, brown, gravel, brown, (CL)-3 (CL)-3 Block 1. Lot 1 , Block 1, Lot 1, 270'5 & 180'E of 160'5 & 280'E of NW property NW property comer comer 873 873 1 ' l' DATE TAKEN: UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 111 113 Moisture Content (%) 13.1 12.6 Plus #4 Material (%) 3 3 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91 , Procedure "An, (-#4 Basis) Maximum Dry Density (pcf) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 98 95 100 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as 0 the a quacy of fill and compaction at locations and elevations other than hos ested. T ese tests were performed by M. LemkelTwin City Testing. REVIEWED BY: proj F:\BMC\99CME\9909463\d68-69.doc STOA~@ Twin CI(Y Testing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 DATE: OctoberS, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 60 61 62 63 DATE TAKEN: 10-2-99 10-2-99 10-2-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 1 0-2-99 UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) Sandy lean clay with a little gravel, brown, (CL)-3 LOCATION: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Block 1, Lot 2, Block 1, Lot 2, Block 1, Lot 2, Block 1, Lot 1, 60W & 130'S of 132'S & 5SW of 220'S & 70W of 150'S & 120W NE property NE property NE property of NE property corner corner comer comer 852 854 855 854 2' 6" l' l' Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 113 114 Moisture Content (%) 12.0 14.1 Plus #4 Material (%) 8 8 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 112 12.9 6 114 13.7 6 Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 113.1 16.1 Compaction Specified Compaction (%) (%) 100 95 101 95 99 95 101 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as to the adequacy of fill and compaction at locations and elevations other tha thos t d. The e tests were performed by M. LemkelTwin City Testing. REVIEWED BY: STOA~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 6, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 64 65 66 67 DATE TAKEN: 1 0-4-99 10-4-99 1 0-4-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 10-4-99 UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) Sandy lean clay with a little gravel, brown, (CL)-3 LOCATION: ELEVATION OF TEST: (feet) BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Fountain Hills Fountain Hills Fountain Hills Block 1, Lot 2, Drive, Sta 1 +20, Drive, Sta 3+00, Drive, Sta 3+68, 125'S & 100W Sanitary sewer Sanitary sewer Sanitary sewer of NE property backfill backfill backfill comer 857 3~ 3' 3' 3" 3" 6" 6" Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 111 113 Moisture Content (%) 12.2 13.5 Plus #4 Material (%) 4 2 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 110 15.1 6 112 14.2 2 Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 113.1 16.1 Compaction Specified Compaction (%) (%) 98 95 100 95 97 95 99 95 REMARKS: REVIEWED BY: are valid at the location and elevation of the test only. No representation ade as the equacy of fill and compaction at locations and elevations other thos t ste ere performed by M. StraightfTwin City Testing. STOA~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 6, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Po Ita 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 68 69 DATE TAKEN: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 1 0-4-99 10-4-99 Sandy lean clay Sandy lean clay with a little with a little gravel, brown, gravel, brown, (CL)-3 (CL)-3 Block 1, Lot 2, Block 1, Lot 1, 50'N & 140W of 125'N & SOW of SE property SE property corner comer 863 871 6" 6" UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 109 110 Moisture Content (%) 15.2 14.9 Plus #4 Material (%) 2 2 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 96.5 95 97 95 REVIEWED BY: s are valid at the location and elevation of the test only. No representation quacy of fill and compaction at locations and elevations other h e tests were performed by M. StraightfTwin City Testing. REMARKS: STOA~@ Twin CitY Testing Corporation TO: PROJECT: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 DATE: October 13, 1999 PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott DENSITY TESTS OF COMPACTED FILL TEST NUMBER: 70 71 72 73 DATE TAKEN: 10-5-99 10-5-99 1 0-5-99 10-5-99 UNIFIED SOILCLASSIFICA TION: Sandy lean clay Sandy lean clay Sandy lean clay Sandy lean clay (Moisture-Density Sample Number) with a little with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 (CL)-3 LOCATION: Block 1, Lot 2, Block 1, Lot 2, Block 1, Lot 1, Block 1, Lot 1, 100'S & 100W 190'S & 90W of 140W & 80'S of 136W & 82'S of of NE property NE property NE property NE property corner comer corner comer ELEVATION OF TEST: (feet) 858 860 868 870 DEPTH BELOW EXISTING GRADE: l' l' 2.5' 6" FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 108 111.5 Moisture Content (%) 14.1 14.7 Plus #4 Material (%) 6 6 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 113 10.8 6 114 13.7 6 Method ASTM:D698-91 , Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 95.5 95 REMARKS: REVIEWED BY: 113.1 16.1 113.1 16.1 98.5 95 100 95 100.5 95 Density tests are valid at the location and elevation of the test only. No representation is made as t the adequacy of fill and compaction at locations and elevations other tha thos t sted. ese tests were performed by M. Lemkerrwin City Testing. Pr ect Manager F:\BMC\99CME\9909463\d70-73.doc STOA~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 13, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 74 75 76 DATE TAKEN: 1 0-5-99 1 0-5-99 1 0-5-99 UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) Sandy lean clay with a little gravel, brown, (CL)-3 Sandy lean clay with a little gravel, brown, (CL)-3 Sandy lean clay with a little gravel, brown, (CL)-3 BELOW SUBGRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Fountain Hills Fountain Hills Fountain Hills Court, Sta 4+00, Court, Sta 3+10, Drive, Sta 2+50, Water main Water main Water main treoch trench trench 3' 3' 6" 6" 3' 6" LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 108 110.5 114.5 Moisture Content (0/0) 16.1 15.3 14.9 Plus #4 Material (0/0) 3 7 7 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 113.1 Optimum Moisture (%) 16.1 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 95.5 95 97.5 95 101 95 Density tests are valid at the location and elevation of the test only. No representation the adequacy of fill and compaction at locations and elevations other sted. Th se tests were perfonned by M. LemkelTwin City Testing. REMARKS: REVIEWED BY: STOR~@ Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: October 13, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 77 78 79 DATE TAKEN: 10-6-99 10-6-99 10-6-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 Block 1, Lot 2, Block 1, Lot 2, Block 1, Lot 1, 120'5 & 160W 250'S & 100W 100'5 & 110W of NE property of NE property of NE property corner corner corner 861 862 873 6" 6" 6" UNIFIED SOILCLASSIFICATION: (Moisture-Density Sample Number) LOCATION: ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pcf) 116 116 Moisture Content (%) 9.8 11.1 Plus #4 Material (%) 10 12 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 114.5 12.1 8 Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pcf) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 Compaction Specified Compaction (%) (%) 102.5 95 102.5 95 101 95 REMARKS: 80 10-6-99 Sandy lean clay with a little gravel, brown, (CL)-3 Block 1, Lot 1, 140'S & 80W of NE property corner 873 6" 115 12.5 8 113.1 16.1 101.5 95 Density tests are valid at the location and elevation of the test only. No representation is made as 0 the adequacy of fill and compaction at locations and elevations other t tho ested. ese tests were perfonned by M. LemkelTwin City Testing. REVIEWED BY: Proj ct Manager F:\BMC\99CME\9909463\d77 -SO.doc ~TOA~@ Twin (,n.y Testing Corporation PROJECT: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 DATE: October 13, 1999 TO: PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 81 82 DATE TAKEN: UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) ELEVATION OF TEST: (feet) DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: 10-7-99 10-7-99 Sandy lean clay Sandy lean clay with a little with a little gravel, brown, gravel, brown, (CL)-3 (CL)-3 Block 1, Lot 2, Block 1, Lot 2, 120'S & 70W of 260'S & 85W of NE property NE property corner comer 863 863 6" 6" LOCATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 115 113 Moisture Content (%) 12.1 14.0 Plus #4 Material (%) 8 8 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 101.5 95 100 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as t the adequacy of fill and compaction at locations and elevations other th~ hos t ted. The tests were performed by M. LemkefTwin City Testing. proj Ma ager F :\BMC\99C ME\9909463\d81-82.doc REVIEWED BY: STOR~@ Twin City Testing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 DATE: October 13, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 83 84 85 86 DATE TAKEN: UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) 10-8-99 10-8-99 10-8-99 Sandy lean clay Sandy lean clay Sandy lean clay with a little with a little with a little gravel, brown, gravel, brown, gravel, brown, (CL)-3 (CL)-3 (CL)-3 1 0-8-99 Sandy lean clay with a little gravel, brown, (CL)-3 LOCATION: Future lot, 120'5 Future lot, 150'5 Fountain Hills Fountain Hills & 20'W of & 25'E of Drive, Sta 7+00, Drive, 5ta 8+50, culdesac, culdesac, Water main Water main, Fountain Hills Fountain Hills trench trench Court Court ELEVATION OF TEST: (feet) 871 869 BELOW SUBGRADE: 3' 3' DEPTH BELOW EXISTING GRADE: l' l' l' l' FIELD DENSITY DETERMINATION: Method Nuclear Density Direct Transmission, ASTM:D2922-91 (-#4 Basis) Dry Density (pet) 112.5 113 Moisture Content (%) 13.1 12.6 Plus #4 Material (%) 8 8 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: 114 11.9 8 112 12.7 8 Method A5TM:D698-91, Procedure "A", (-#4 Basis) Maximum Dry Density (pet) 113.1 113.1 Optimum Moisture (%) 16.1 16.1 COMPACTION TEST RESULTS: 113.1 16.1 113.1 16.1 Compaction Specified Compaction (%) (%) 99.5 95 100 95 100.5 95 99 95 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made a to the adequacy of fill and compaction at locations and elevations other th tho tested. ese tests were performed by M. LemkelTwin City Testing. REVIEWED BY: STOR~@ Twin (;rey Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: November 4, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 87 88 89 DATE TAKEN: 11-4-99 11-4-99 UNIFIED SOILCLASSIFICA TION: (Moisture-Density Sample Number) Crushed limestone (Proctor #5) Crushed limestone (Proctor #5) LOCATION: Fountain Hills Drive, Sta 1+75, 1 O'S of centerline Fountain Hills Drive, Sta 3+00, centerline DEPTH BELOW BASE GRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: At base grade At base grade Method Nuclear Density Direct Transmission, ASTM:D2922-91 (Overall Basis) Dry Density (pcf) 123 122.5 Moisture Content (%) 7.0 8.1 Plus #4 Material (%) 65 65 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "C", (-3/4" Basis) Maximum Dry Density (pet) 120.6 120.6 Optimum Moisture (%) 8.8 8.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 102 100 101.5 100 90 11-4-99 11-4-99 Crushed limestone (Proctor #5) Crushed limestone (Proctor #5) Fountain Hills Court, Sta 1 +25, 5'W of centerline Fountain Hills Court, Sta 4+10, centerline At base grade At base grade 123 7.0 65 121.5 7.4 65 120.6 8.8 120.6 8.8 102 100 100.5 100 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as to the adequacy of fill and compaction at locations and elevations other than those tested. The test locations and number of tests were lected by Twin City Testing. These tests were performed by J. Hanson of Twin City Testing. REVIEWED BY: Proj ct Manager F:\BMC\99CME\9909463\D87 -90.doc STOA~@ Twin ~llY Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 DATE: November 4, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: '1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TEST NUMBER: DENSITY TESTS OF COMPACTED FILL 91 92 DATE TAKEN: 11-4-99 11-4-99 UNIFIED sOILCLAsSIFICA TION: (Moisture-Density Sample Number) Crushed limestone (Proctor #5) Crushed limestone (Proctor #5) LOCATION: Fountain Hills Drive, Sta 5+00, 10'N of centerline Fountain Hills Drive, Sta 7+50, 5'5 of centertine DEPTH BELOW BASE GRADE: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION: At base grade At base grade Method Nuclear Density Direct Transmission, ASTM:D2922-91 (Overall Basis) Dry Density (pet) 121.5 123 Moisture Content (%) 6.5 6.4 Plus #4 Material (%) 65 65 LABORATORY COMPACTION CHARACTERISTICS OF SOIL: Method ASTM:D698-91, Procedure "C", (-3/4" Basis) Maximum Dry Density (pet) 120.6 120.6 Optimum Moisture (%) 8.8 8.8 COMPACTION TEST RESULTS: Compaction Specified Compaction (%) (%) 100.5 100 102 100 REMARKS: Density tests are valid at the location and elevation of the test only. No representation is made as to the adequacy of fill and compaction at locations and elevations other than those tested. The test locations and ~~~~~ Of~^sts wr(S~win City Testing. These tests were performed by J. Hanson of Twin City REVIEWED BY: rJ\ _~ ~ Proj ct M~ ager ..... F:\BMC\99CME\9909463\D91-92.doc STO A I.., Twin City lesting Corporation PROJECT: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: September 2, 1999 TO: PROJECT NO: 9909463 SAMPLE NO: 1 MAXIMUM DENSITY: ASTM: D698-91, Procedure A Sandy lean clay, brown, (CL) 112.1 OPTIMUM MOISTURE: 15.8 METHOD OF TEST: TYPE MATERIAL: 110 -- - " """ " , ~ .J , -.... , "- , "- r , 1-' " " " l~ " I~ " r II 115 114 113 .... u a- t- 'en c ~ C ~ 112 c 111 109 13 14 15 16 Moisture Content, % 17 18 Information Llnd SldlHlllents In 1I1lS rl-!port dIe de lived horn rn,llelldl Illlorrndtloll ,.\Ildlll spt'C:IIII:,1l10PS Iwnlslled tlY IIII-! c1it'nl ,1Ild I-!xchldt' ,lilY expreSSI-!C! or Implied warranties as to the htness ot the 1ll,llpll,ll le'il.!d III ,1Il,llyzl'd lor dny p,lfllClIldl pllfpOSt' III liSP fillS rl-!J'olIIS HIt' I:clltlllenll,ll propprty of 011I c11t'1l1 ,1Ild II1.lY not Ill-! IISI-!rllor dc1vt!rtlslng purposes This report StldllllOI Ill-! reprodllcI'd I'XC:l'pllll 11111 WIHHlI.1 Wllttl'1l ,IPP'OV,ll of HIlS 1.111<11,111\1'1 Tilt' "'colltlnq t)f Idl:;P IICIIIl<lIlS ,)I 11.1I1<11IIelll sl,ll"Illl'llls nr I'nllll's on Ihls document may be plllllStlPtl ,"i d ,..Ion 'I III"It'1 F.!dt'I,11 ';1.11111.", 1I1<:llIdll"l Ft-d"'dll ,IW f,llt- I~ C11,11'1.'II" . STOAI~ Twin City resting Corporation PROJECT: Ms. Kelly Murray Wensmann Homes RHs Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue. St. Paul, MN 55114-1776 (651) 645-3601. Fax: (651) 659-7348 DATE: September 2, 1999 TO: PROJECT NO: 9909463 SAMPLE NO: 2 METHOD OF TEST: ASTM: D698-91, Procedure A Sandy lean clay, brown, (CL) 112.8 OPTIMUM MOISTURE: 15.0 TYPE MATERIAL: MAXIMUM DENSITY: 110 ... .... ~ ~ I'. ,. "'" ..J '" " "I , '" .", " \. , ~ \. / , , \ \ \ \. \. \ , \ 115 114 113 .... u ~ >; ... 'C;; C GJ C ~ 112 c 111 109 13 14 15 16 Moisture Content, % 17 18 Inlormalion and stdtf!fT1f!l1tS III 1t1lS IPPOrt .11P <lPrlVf!d trofT1 rllatprI,ll Il1tlJlrllatlOI1 .1I11tor "P"ICltlt:.llIOr'S trJflllSllP<l by Itl" r:l1f!111 ,m<l PXl~llId" ,lilY expIPsse<l <)r Impliect warranties as to the fitness ot It1f~ In,lIPrlalteste<l <)1 ,1I1dlyzed fllr ,my 1',1111(:111,11 plllpOSf! or lIse fillS mp'lIt IS It,P ,:,',,,I,,Jpl111.\1 pfllp"'ly III <lIJf <:Irt'l1t ,111<1 fT1ay l10t hp tlspd tor arJvertlslng purposes This report ,;hdlll1ot h., (t~pf()dll<:pd .,xc"pl III hili Wltt"",t Wllttp" ,1ppIOV.ll ,,11111S l.ltJO!;1I11Iv fI,P ,,,,~o.dll1q .11 1.1Is., t,,:IIIIOllS III tr.lI"hllt'111 st,llprlltH11,; or p"trles on Ihls document may tltl ptllll:;ll.'d ,,:; ,I fpl,,"v 11I,,1t'1 ft'd"'.11 ';I.rllil.", 1I1<:llIdll1'1 [.'d.'!;111 .IW fill" IH ell,lpl.,!,: STORI~ Twin City resting Corporation PROJECT: Ms. Kelly Murray Wensmann Homes RHs Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: September 14, 1999 TO: PROJECT NO: 9909463 SAMPLE NO: 3 MAXIMUM DENSITY: ASTM: D698-91, Procedure A Sandy lean clay, brown, (CL) 113.1 OPTIMUM MOISTURE: 16.1 METHOD OF TEST: TYPE MATERIAL: 111 .....- -.... ., I.... ~ ~ ........ '" ~ '" ~ "" , :'- \. / / ""i ./ " " ~ 1\ " \. , I\. -., , ~ 1'\ \ 116 115 114 '0 a. i- 'C;; c Q) C ~ 113 c 112 110 14 15 16 17 Moisture Content, % 18 19 Information .m<J :itaternel1ls Ifl this report ,IIA dAJlved frol11 nklterkll. II1torl11atlon ,md.or spAclllc,ltlllflS fUrrllshpl! by fhf! cllf'l1t ,11111 exclude ,my exprAsse<J or Implied warranties as to Ihe fitness 01 thA l11,ltpfl.lI lestAd or ,lIl.lIYled tor ,lilY p.lrllcul;u pili pose or USf' fhls IAlll...1 IS Itlt> ,:0111,,1el1tl.ll properly of Olll cllt-!I1t Jrld 111.1Y Ilot be used for advertiSing purposes ThiS reporl ,>11.111 Ilot be IAproducAd excppt Ifl It,ll. wlltlollr WJlttAIl ,1PPIOV.ll of IhlS 1.1lltll,HoIY rtlA r"COf(l'rlq of l.llsA ItctlllOlIS or fraudulent st,Hernents ()I Antllf'S on thiS document may be punlstll'd .";ol IAIol1Y IIrl<tpl F.'d!'!.11 St.ltlltl''' II1<'II11hnq f"deloll L,IW flth> tH. Ch.lplt>1 -I; STO R 1....,0 Twin City Testing Corporation PROJECT: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive, Suite 200 Eagan, MN 55122 FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: October 27,1999 TO: PROJECT NO: 9909463 SAMPLE NO: 5 METHOD OF TEST: TYPE MATERIAL: ASTM: D698-91. Procedure C Crushed limestone MAXIMUM DENSITY (pet): 120.6 123 OPTIMUM MOISTURE (%): 8.8 118 .... .... l..o- ..... ~ l"I , r-.... " ~ '\. , " ~ \. ~ , .., , J , 1/ \ J \ 1\ l 122 121 .... u a. ~ en c QJ Q ~ 120 Q 119 117 6 7 8 9 Moisture Content, % 10 11 Information and statements In thiS report are denved from matenal, Information and/or specIfications furnished by the chent and exclude any expressed or Imphed warranties as to the fitness of the matenal tested or analyzed for any particular purpose or use ThiS report IS the confidential property at our client and may not be used for advertising purposes. ThiS report shall not be reproduced except.n full, Without wntten approval of thiS laboratory The recording of false. fictitiOus or fraudulent statements or entnes on thiS document may be punished as a felony under Federal Statutes Including Federal Law Title 18, Chapter .17 STOR~@ Twin City 'Testing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA SAMPLE NUMBER: DATE RECEIVED: SAMPLE IDENTIFICATION: LOCATION SAMPLED: UNIFIED SOIL CLASSIFICATION: MECHANICAL ANALYSIS: Passing 4" 1-1/2" 3/4" 3/8" #4 #10 #40 #100 #200 DATE: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 October 21, 1999 PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TESTS OF SOIL 1 10-15-99 Proposed select granular Fountain Hills Drive, Sta 0+15 Silty Sand with gravel, mostly fine grained, brown (SM) 100 91 87 83 76 70 49 23 13 REMARKS: These tests were performed by H. Peterson on 10-15-99. Sample #1 fails to meet MnD t pecification for select granular material. REVIEWED BY: Information and statements in this report are derived from material. information and/or specifications fumished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use, This report is the confidential property of our client and may not be used for advertising purposes, This report shall not be reproduced except In full. without written approval of this laboratory. The recording of false. fictitious or fraudulent statements or entries on thiS document may be punished as a felony under Federal Statutes including Federal Law Title 18. Chapter 47 STO R 1Ji@ Twin City Testing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA SAMPLE NUMBER: DATE RECEIVED: SAMPLE IDENTIFICATION: LOCATION SAMPLED: UNIFIED SOIL CLASSIFICATION: MECHANICAL ANALYSIS: Passing 4" 3" 1-1/2" 3/4" 3/8" DATE: 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 October 21, 1999 PROJECT NO: 9909463 COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott TESTS OF SOIL 2 10-18-99 Proposed select granular fill Fountain Hills Court, Sta 3+00 Sand with silt and gravel, medium to fine grained. brown (SP-SM) 100 84 80 78 73 #4 68 #10 62 #40 32 #100 15 #200 7.2 REMARKS: These test were performed by M. Molitor on 10-18-99. REVIEWED BY: Information and statements in this report are derived from material. information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report IS the confidential property of our client and may not be used for advertising purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be pUnished as a felony under Federal Statutes including Federal Law Title 18. Chapter 47 STOR~@ Twin City festing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT NO: 9909463 DATE: October 21, 1999 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COPIES TO: 1-Pioneer Engineering-Nick Polta 1-Enebak Construction-Nathan Adams 1-City of Prior Lake-Susan McDermott SAMPLE NUMBER: DATE RECEIVED: SAMPLE IDENTIFICATION: LOCATION SAMPLED: TESTS OF SOIL 3 10-18-99 Select Granular Fill Fountain Hills Drive, Sta 2+00 Sand, mostly medium grained, brown (SP) UNIFIED SOIL CLASSIFICATION: MECHANICAL ANALYSIS: Passing 3" 100 100 100 100 1-1/2" 3/4" 3/8" #4 97 #10 87 #40 17 #100 4.4 #200 1 REMARKS: These tests we e performed by M. Molitor on 10-18-99. REVIEWED BY: 4 10-18-99 Select Granular Fill Fountain Hills Drive, Sta 6+25 Sand with silt and gravel, mostly medium grained, brown (SP-SM) 100 87 85 80 74 66 30 12 5.6 Information and statements in this report are derived from material. information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the material tested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertising purposes. ThiS report shall not be reproduced except in full. without written approval of this laboratory The recording of false. fictitious or fraudulent statements or entries on this document may be pUnished as a felony under Federal Statutes including Federal Law Title 18. Chapter 47 STOR~@ Twin City Testing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: October 27,1999 PROJECT NO: 9909463 GENERAL: TEST OF BASE AGGREGATE On October 25, 1999, two samples of base aggregate were obtained at the jobsite by J. Hanson with Stork Twin City Testing Corporation. The scope of our laboratory work was limited to determining the mechanical analysis of the base aggregate. We conducted the tests on October 26, 1999, in conformance with the indicated procedures. The samples are in compliance with the aggregate gradation requirements of MN/DOT Specification 3138 for Class 5 Base Aggregate. SAMPLE NUMBER: TYPE OF AGGREGATE: 5 Crushed limestone Fountain Hills Court, Sta 4+50, on centerline LOCATION SAMPLED: 6 Crushed limestone Fountain Hills Drive, Sta 5+00, 10'S of centerline TEST PROCEDURE: ASTM: C136, C117, C131 1988 MN/DOT SPECIFICATION 3138 Class 5 MECHANICAL ANALYSIS: Passing 1" 3/4" 1/2" 3/8" #4 #10 #40 #100 #200 1000/0 1000/0 1000/0 94 92 90-100 74 70 60 57 50-90 35 35 35-80 20 25 20-65 13 17 10-35 10 12 7.6 7.8 3-10 \ REVIEWED BY: F:\BMC\99CME\9909 1G-28.doc Information and statements in this report are derived from material. information and/or specifications furnished by the client and exclude any expressed or implied warranties as to the fitness of the matenaltested or analyzed for any particular purpose or use. This report is the confidential property of our client and may not be used for advertiSing purposes. This report shall not be reproduced except in full, without written approval of this laboratory. The recording of false. fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 STO RI~") Twin City festing Corporation TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive Suite 200 Eagan, MN 55122 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 DATE: October 28, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA TESTS OF PLASTIC CONCRETE TEST PROCEDURES: AsTM:C172 - Sampling Freshly Mixed Concrete; ASTM:C143 - Slump of Portland Cement Concrete; ASTM:C231 - Air Content of Freshly Mixed Concrete by the Pressure Method (Air Meter Number 5376); ASTM:C31 - Making and Curing Concrete Test Specimens in the Field; . FIELD DATA: Date of Test: Mix Designation: Concrete Supplier: Location of Placement: Method of Placement: Total Yards Observed: Weather: Field Technician: 1 0-25-99 3A22 Camas Curb and Gutter, Fountain Hills Court Sta 3+75, East side; Fountain Hills Court Sta 4+75, West side Curb Machine 20 Sunny, 500 J. Hanson The following tests were Derformed at the truck, exce:>t as noted: Time of Truck Slump Air Content Concrete Cylinders Water Plasticizer Conments Tests Number (in.) (%) Temp. (oF) Cast Added (gat) Added (gat) 11 :OOam 160 1% 4.9 62 1A-C 11 :35am 139 2 5.5 68 2A-C Project Specs. Min. 4.5-7.5 55-90 Max. 2 The concrete test cylinders were temporarily stored at the project and then submitted to our laboratory for moist curing and compression testing. Compression test res will be reported separately as they become available. G:\99CME\9909463\PlASTICS\ 10-25 Informallon and statements In thiS report are denved from matenal. Information and/or speclficallons furnished by the client and exclude any expressed or Implied warranlies as to the fitness of the matenaltested or analyzed for any particular purpose or use. ThiS report IS the confidential property of our chent and may not be used for advertising purposes. ThiS report shall not be reproduced except In full. Without wntten approval of thiS laboratory The recording of false. ficlilious or fraudulent statements or entnes on thiS document may be punished as a felony under Federal Statutes Including Federal Law Title 1 B. Chapter .l7 STORI~(~) Twin City Testing Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive Suite 200 Eagan, MN 55122 TO: DATE: November 23, 1999 PROJECT NO: 9909463 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number. Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: REMARKS: 1A 1B 1C 10-25-99 10-25-99 10-25-99 7 28 Hold 1% 1% 1% 4.9 4.9 4.9 Curb and Gutter, Fountain Hills Court Sta 3+75, East side 3900 3A22 Camas J. Hanson" ASTM:C39 - Compression Test; AsTM:C1231 - Capping 009520-A 6.00 12.00 28.27 10-28-99 3 4 11-1-99 8:10am Shear 136030 4810 009520-8 6.00 12.00 28.27 10-28-99 3 25 11-22-99 9:17am Shear 187580 6630 009520-C 6.00 12.00 28.27 10-28-99 3 Hold The 28-day compression test results meet the specified strength. J I I r ~ .c~ p .~ l I~chlegel - Supervisor G:\99CME\9909463\D09520 Inlormallon and statements In this report are denved lrom matenal. Inlormation and/or speclllcalions lumished by the client and exclude any expressed or implied warranties as to the IItness 01 the matenal tested or analyzed lor any particular purpose or use. This report IS the conlldential property 01 our client and may not be used lor advertising purposes This report shall not be reproduced except In full. Without wntten approval 01 this laboratory The recording ollalse. ficlltlous or fraudulent statements or entries on this document may bf! punished as a felony under Federal Statutes Including Federal Law Title 18. Chapter H STOAI~') Twin City resting Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building, 1895 Plaza Drive Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA DATE: November 23, 1999 PROJECT NO: 9909463 COMPRESSION TESTS OF CONCRETE CYLINDERS FIELD DATA: Job Identification: Date Cast: Age to be Tested, days: Slump, in. (ASTM:C143): Air Content, % (ASTM:C231): Location of Placement: Specified Strength, psi: Mix Designation: Concrete Furnished By: Cylinders Cast By: TEST PROCEDURES: TEST RESULTS: Laboratory Number: Diameter, in: Height, in: Area, sq. in: Date Received: Days on Job & Enroute: Days Lab Cured (ASTM:C192): Date of Test: Time of Test: Type of Fracture: Load at Failure, lb.: Compressive Strength, psi: 2A 2B 2C 10-25-99 10-25-99 10-25-99 7 28 Hold 222 5.5 5.5 5.5 Curb and Gutter, Fountain Hills Court sta 4+75, West side 3900 3A22 Camas J. Hanson ASTM:C39 - Compression Test; ASTM:C1231 - Capping 009521-A 6.00 12.00 28.27 10-28-99 3 4 11-1-99 8:10am Shear 132340 4680 009521-B 6.00 12.00 28.27 10-28-99 3 25 11-22-99 9:25am Shear 178130 6300 009521-C 6.00 12.00 28.27 1 0-28-99 3 Hold REMARKS: The 28-day compression test results meet the specified strength. ~~~ ~.S/ Supervisor G:\99CME\9909463\O09521 Informaflon and sfatements In lhls report are derived from material. Information and/or speCifications furnished by the clienl and exclude any expressed or implied warranties as 10 the fllness of lhe malerlallesled or analyzed for any particular purpose or use This report IS the confidential property of our client and may not be used lor advertising purposes This report shall not be reproduced except In full. Without wntten approval of this laboratory The recording of false. fictitiOUS or fraudulent statements or entnes on this document may be punished as a felony under Federal Statutes Includulq Federal Law Title 18. Chapter .l7 STORK@ Twin City resting Corporation 662 Cromwell Avenue, St. Paul, MN 55114-1776 (651) 645-3601, Fax: (651) 659-7348 TO: Ms. Kelly Murray Wensmann Homes RHS Building 1895 Plaza Drive, Suite 200 Eagan, MN 55122 PROJECT: FOUNTAIN HILLS PRIOR LAKE, MINNESOTA DATE: November 15,1999 PROJECT NO: 9909463 COpy TO: 1-Pioneer Engineering 1-Enebak Construdion 1-City of Prior Lake REPORT OF ASPHALTIC CONCRETE MIXTURE TESTING SAMPLE NUMBER: 1 DATE SAMPLED: 11-10-99 DATE TESTED: 11-11-99 LOCATION TAKEN: Fountain Hills Court, Sta 4+50 Test Procedures: ASPHALT CONTENT (%l: ASTM: C136, ASTM: C117, ASTM: 02172 5.6 Mechanical Analvsis: Passing 3/4" 1/2" 3/8" #4 #10 #40 #80 #200 1000/0 93 84 68 54 21 7.0 4.5 2331B BASE SPECIFICATIONS 1000/0 40 - 85 2-8 REMARKS: Sample #1 meets project gradation specifications for 2331B Base mixture. The sample was consumed during testing or discarded at the conclusion of testing. By: G:\SHARE Information and statements In this report are derived from material, information and/or specifications fumished by the client and exclude any expressed or implied warranties as to the fitness of the matenal tested or analyzed for any particular purpose or use. This report IS the confidential property of our client and may not be used for advertising purposes. ThiS report shall not be reproduced except in full, without wntten approval of this laboratory. The recording of false, fictitious or fraudulent statements or entries on this document may be punished as a felony under Federal Statutes including Federal Law Title 18, Chapter 47 Geotechnical Exploration Program Prior Hills Business Park County Road 42 and Pike Lake Trail Prior Lake, Minnesota Maxim Project No. 9754408 Prepared for: Wensmann Homes, Inc. 3312 151st Street West Rosemount, MN January 26, 1998 MAXIM TECHNOLOGIES INC January 26, 1998 Ms. Kelly Murray Wensmann Homes, Inc. 3312 151st Street West Rosemount, MN RE: Geotechnical Exploration Program Prior Hills Business' Park County Road 42 and Pike Lake Trail Prior Lake, Minnesota Maxim Project No. 9754408 We have completed the subsurface exploration and geotechnical engineering review for the above referenced project. This report presents the results of our field and laboratory testing programs, and provides recommendations concerning the soil and groundwater conditions as they relate to the proposed construction. The soil samples will be retained in our laboratory for 30 days, at which time we will dispose of them. If you desire us to retain the samples longer than 30 days, please notify us. Weare pleased to be of service to you in this important phase of the project. If there are any questions regarding the information contained in this report or if we can be of further service to you, please contact us at your convenience. Respectfully, st~ Steven J. Olson, P. E. Senior Geotechnical Engineer cc: 1- Ryan Engineering GEO\SJO\9754408r 662 Cromwell Avenue. St. Paul, MN 55114-1776. 612-645-3601 · Fax: 612-659-7348 Austin Research Engineers · Chen-Northern · Empire Soils Investigations Kansas City Testing · Southwestern Laboratories · Twin City Testing An Affirmative Action 0 Equal Opportunity Employer TABLE OF CONTENTS PAGE 1.0 INTRODUCTION ............................................ 1 1.1 Project Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Scope of Geotechnical Services .................................. 1 2.0 TESTING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.1 Field Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.2 Laboratory Review .......................................... 2 3.0 FffiLD TESTING RESULTS ...... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.1 Site Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.2 Subsurface Conditions ........................................ 3 3. 3 Water Levels . .'. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4.0 REVIEW AND RECOMl\tlENDATIONS ..... . . . . . . . . . . . . . . . . . . . . . . . . 4 4.1 Project Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4.2 Site Preparation ............................................ 4 4.3 Foundations . . . . . . . . . . . '.' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.4 Floor Slabs ............................................... 6 4. 5 Underground Utilities ........................................ 6 5.0 CONSTRUCTION CONSIDERATIONS ............................. 7 5.1 Excavation Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5.2 Quality Control. . . . . . . . . . . . . . . . . . . '. . . . . . . . . . . . . . . . . . . . . . . . . 7 5.3 Winter Construction ......................................... 7 5.4 Soil Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 6.0 REl\'IARKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 APPENDIX A Boring Location Plan Boring logs Symbols and Terminology on Test Boring Log Field Exploration Procedures APPENDIX B Laboratory Test Results APPENDIX C Construction Observations and Testing Precautions for Excavating and Refilling During Cold Weather APPENDIX D Interpreting a Geotechnical Engineering Report MAXIM 1.0 INTRODUCTION We have completed the geotechnical exploration for the Prior Hills Business Park in Prior Lake, Minnesota. Maxim Technologies, Inc. (Maxim) was retained by you to perform this exploration. This report presents the results of the field exploration, laboratory review and our geotechnical review and recommendations. 1.1 PrQject Description The proposed project will be development of the property for office and industrial buildings. The preliminary plans are for seven lots on the property, as shown on the drawing in Appendix A. The site is located southwest of County Road 42 and Pike Lake Trail in Prior Lake, Minnesota. 1.2 Scope of Geotechnical Services The scope of our preliminary services for this project is limited to the following: 1. Explore the subsurface soil and groundwater conditions by performing seven soil borings each to at least a depth of 21 feet. 2. Perform laboratory tests on selected soil samples to aid in soil classification. 3. Prepare an engineering report which will include the soil boring logs and our preliminary recommendations for: a. Grading procedures for the building. b. Foundation types and depths, allowable soil bearing pressures with estimates of foundation settlement. c. Support for floor slabs. The services are for preliminary design. Additional borings should be performed when the building types and locations are known at each lot of the development. Our services performed for this project were primarily for geotechnical purposes only, and not for documenting the potential presence or extent of any environmental contaminants at the site. MAXIM Maxim Project No. 9754408 Page 2 2.0 TESTING PROCEDURES 2.1 Field Testin2 The Standard Penetration Test (SPT) borings were made on November 26, 1997. A boring was performed in each lot for preliminary planning purposes. The boring locations were selected by Maxim and are shown on the drawing included in Appendix A. The locations were selected to be within each of the planned lots. The ground surface elevations shown on the boring logs were referenced to the temporary benchmark established by Ryan Engineering, Inc. The surface elevations are shown on the respective boring logs. The soil borings were performed with a rotary type drill rig mounted on a truck using continuous hollow stem augers to advance the boreholes. Representative soil samples were obtained using split-barrel sampling procedures in general conformance with the ASTM Standards noted on the Field Exploration Procedures sheet inclu'ded in Appendix A. Water level observations were made in the boreholes during and upon completion of the drilling and sampling operations. During the field operations, the drill crew maintained logs of the subsurface conditions including changes in stratigraphy and the measured groundwater levels. The soil data and the groundwater levels are shown on the boring logs in the same appendix. After completion of the drilling operations, the boreholes were backfllled with auger cuttings and bentonite chips to the existing ground surface. 2.2 Laboratory Review The soil samples obtained during the drilling operations were logged, labeled, sealed and delivered to our laboratory for further observations. The soil samples were classified in general conformance with ASTM standards. MAXIM Maxim Project No. 9754408 Page 3 3.0 FIELD TESTING RESULTS 3.1 Site Conditions The site has areas of both trees and open land. There are also a few small wetlands throughout the property. The topography is generally rolling hills. The surface elevations range from 838 feet at the northwest comer to 906 feet at the south center of the property, based on the topographic map provided by Ryan Engineering, Inc. The surface elevations at the boring locations ranged from 838.5 to 887.3 feet at borings B-1 and B-4 , respectively. 3.2 Subsurface Conditions The subsurface conditions at the test boring locations are shown on the test boring logs. The boring logs also indicate the possible geologic origin of the materials encountered. We wish to point out that the conditions at other times and locations on the site may differ from those found at our test locations. If different conditions are encountered during construction, it is necessary that you contact us so that our recommendations can be reviewed. The subsurface conditions, based on the boring logs, suggest primarily natural clayey glacial till throughout the site. At some locations there is uncontrolled flil, organic topsoil and or very soft clayey soils at the surface. The fill/topsoil depth ranges from 0.5 feet to 5.5 feet at boring B-6 and B-2, respectively. The native clay till are very soft to fIrm in consistency, based on the penetration resistances (N values). 3.3 \Vater Levels Groundwater was noticed in boring B-1 during and at the completion of the drilling operations. The water was measured at 4.5 feet below the surface during the exploration and at 14.6 feet at the completion of the boring. The water is most likely perched on less permeable soils, especially at 4.5 feet. Water was not noticed at the other boring locations. Groundwater levels may fluctuate seasonally and annually, depending on many factors. MAXIM Maxim Project No. 9754408 Page 4 4.0 REVIEW AND RECOMl\1ENDATIONS The engineering recommendations made in this report are based on our understanding of the project as described in the following paragraphs. The recommendations are valid for a specific set of project conditions. If the characteristics of the project change from those indicated in this report, it is necessary that we be notified so we may determine whether the new conditions affect our recommendations. 4.1 PrQject Data The project is for site development of the property to include commercial office and industrial buildings. Typically, these buildings will be high, I-story, slab-on-grade structures . We estimate these buildings will have column loads on the order of 100 kips and wall loads of about 5 kips per lineal foot. Floor slab loads may be on the order of 250 pounds per square foot. Building size and locations have not been determined. Additional borings should be performed when building plans have been determiried. 4.2 Site Preparation Site preparation should consist of removing the surface fill, topsoil, and very soft clays. The underlying stiffer native clays should be suitable for building footing support. Lateral oversizing should be provided where the excavation bottom extends below the footings. The lateral oversizing is for distribution of foundation loads through the fill. We recommend the oversizing be a distance at least equal to the depth of fill below the foundations (i. e. I V: IH ratio). Engineered fill should be placed were needed to attain fmal grades. The fill should preferably consist of sands having less than 20 percent passing the #200 sieve. The inorganic soils on-site may be suitable for this fill provided the following compaction and moisture levels are attained. The fill should be compacted to a minimum density of 95 percent of the maximum density determined by the Standard Proctor Test. Fill placed in the upper 3 feet of the parking areas should be compacted to even higher levels. We recommend this fill be compacted to at least 100 percent of the Standard Proctor Test. In addition, the fill should be placed at a moisture content within 3 percent of the optimum as determined by the Standard Proctor Test. MAXIM Maxim Project No. 97544\16 Page 5 Field personnel under supervision of the geotechnical engineer observe the excavations after stripping, surface compaction, and prior to footing placement to document the exposed soil conditions. The fo Howing tabulation shows the approximate elevation of the competent native soils at the respective boring locations: Minimum Boring Ground Surface Excavation Elevation of Number Elevation (ft) Depth (ft) Native Soils (ft) B-1 838.5 4.0 834.5 B-2 873.1 5.5 867.6 B-3 860.6 8.0 852.6 B-4 887.3 1.5 885.8 B-5 851.4 4.0 847.4 B-6 873.8 0.5 873.3 B-7 869.4 7.5 861.9 The above excavation depths are approximate, based on the exploration results. The depth of excavation between and outside the borings may vary, and should be determined in the field at the time of construction. The soil conditions in the excavation bottoms should be documented by the geotechnical engineer or representative prior to fill and foundation placement. The mass excavation should be performed with proper equipment so as not to disturb the soft clays in the excavation bottoms, such as at boring B-3. If the soils become disturbed, additional excavation may be required. 4.3 Foundations After performance of the site preparation as recommended in section 4.2, it is our judgement that the proposed building can be supported on conventional spread footings. The building footings should bear on the native clay soils or on the compacted engineered fill. Footings may be designed for a maximum net allowable soil bearing pressure of 1500 to 3000 pounds per square MAXIM Maxim Project No. 97544u8 Page 6 foot (pst), or more depending on the location and elevation of the footings. We recommend additional boring be performed when specific building location and information is determined. We can then provide specific foundation design recommendations. All perimeter foundations in heated building space should be placed at a minimum depth of 42 inches below exterior grades for frost protection. Interior footings may be placed at any convenient depth below the floor slab. In unheated areas where deeper frost penetration may occur, we recommend that the foundations have a minimum soil cover of 60 inches for frost protection. 4.4 Floor Slabs Floor slabs may be placed directly on the inorganic native soils or compacted engineered fill. Particular attention should be paid to properly compacting the fill against the foundations, walls and in utility trenches beneath the floor slabs. The fill supporting the light to moderate floor slab loads should be compacted to at least 95 percent of the standard proctor density. The floor slabs may be designed to be structurally independent of the building foundations or walls. The floor and subgrade should be constructed to minimize moisture transmission through the slab. A minimum 4-inch thick free-draining granular layer should be placed in contact with the floor slabs. This layer should consist of unifonnly-graded sand or gravel with less than 7 percent passing the #200 sieve. In addition to facilitating fine grading for easier slab construction, the granular layer provides a capillary break to minimize moisture transmission from the sub grade to the floor slab. The native sands classified as SP or SP-SM may be suitable for this material. A polyethylene vapor membrane can also provide added moisture protection beneath the floor slabs from capillary rise. If a membrane is used, it should be placed beneath the layer of clean granular soils. This is to minimize the potential for concrete slab curling. 4.5 Under~ound Utilities The inorganic fill or native soils encountered in the borings appear to be suitable for the support of typical buried utilities. If the soils in utility trenches become disturbed, they could lose shear strength and bearing capacity. Therefore, if disturbed soils are present in the bottom of utility trenches, some subcutting may be necessary. Fill placed as utility bedding should be either MAXIM Maxim Project No. 975440~ Page 7 crushed rock or a clean, well-graded granular soil. All backfill in underground utility trenches in building or pavement areas should be placed and compacted as recommended in Section 4.2 of this report. 5.0 CONSTRUCTION CONSIDERATIONS 5.1 Excavation Safety All excavations should comply with the requirements of O.S.H.A. 29 CFR, Part 1926, Subpart P, "Excavations and Trenches". This document states that excavation safety is the responsibility of the contractor. Reference to these O.S.H.A. requirements should be included in the project specifications . 5.2 Quality Control The geotechnical engineer or engineering assistant should observe the exposed soils to document the conditions prior to fill or footing placement. In addition, density test of the fill should be preformed at 2 foot vertical intervals at each unit to document the compaction level of the fill. 5.3 Winter Construction Since soils undergo moisture volume expansion upon freezing, we are enclosing in Appendix C an information sheet enumerating the precautions which should be observed during winter construction. 5.4 Soil Sensitivity The silty and clayey soils are susceptible to disturbance from construction traffic, especially in wet conditions. If the soils become disturbed, additional excavation may be required. Therefore, proper excavation equipment should be used to minimize the potential for disturbance. MAXIM Maxim Project No. 97544lJo Page 8 6.0 REMARKS The reconunendations contained in this report represent our professional opinions. These opinions were arrived at in accordance with currently accepted engineering practices at this time and location. Other than this, no warranty is implied or intended. Prepared by: SL~ Steven J. Olson, P.E. Senior Geotechnical Engineer Reviewed bY:~~'Lr- Ahsanur R. Siddique, P.E. Geotechnical Engineer I hereby cenify that this plan, specification, or report was prepared by me or under my direct supervision that I am a duly Registered Professional Enli . under the laws 0 Slate of Minnesota. " J Registration No. 18696 Date Januarv 9 1998 MAXIM APPENDIX A BORING LOCATION PLAN BORING LOGS SYMBOLS AND TERMINOLOGY ON TEST BORING LOG FIELD EXPLORATION PROCEDURES MAXIM J~ COUNTY RO~ 42 . fL DING II 838.S Lor 1- OFFIC,E LOT ~ (;fFI~ BORING 12 873J ~ IORING 13 Lm- 4 OFFC,E LQT I INDUSTRIAL mI BORING IS ~J.4 ~ IOJUNG '~87.3 LOT 2 I NDlJ5TRIAL -I - c ~ J- w ~ -c ..I. , , , Lor'\ I INDUSTglAL '. ~ \ BORING \" " 873.8 , , , , , , \ \ w ~ - A- I Lor ~ INDlJ5 TR IALariNG 17 86 . NORTH EB MAXIM LOG OF TEST BORIN I JOB NO. 9754408 VERT I CAL SCALE 1" = 3' BORING NO. B-1 I PROJECT PRIOR HILLS BUSINESS PARK. PRIOR LAKE. MINNESOTA I DEPTH DESCRIPTION OF MATERIAL GEOLOGIC N SAMPLE LABORATORY TESTS I IN ,--SURFACE ELEVATION 838.5 or Qu FEET ORIGIN CR WL NO. TYPE W D LL PL or ROO FILL - mostly lean clay with sand, moist, dark ~>< Fill 11/2 1 SB brown ~>< - ~>< !>)e>< ~)( - D)(< ~ D)(< 11/2 2 SB DY< - ~ 4.0 >y<., ~ LEAN CLAY with a little sand and gravel, moist to ~ Glacial SZ wet, brown to brown and gray mottled, with lenses Till - - and laminations ofwaterbearing sand (CL) ~ 6 3 SB - - ~ ~ 8 4 I SB \ - - ~ - ~ - 5 SB 10 - ~ - ~ ~ 12 6 SB - ~ - ~ - ~ ~ 15.0 ~ ..... SANDY LEAN CLA Y with a trace to a little gravel, ~ 12 7 SB moist, gray (eL) - ~ - ~ ~ ~ - ~ - ~ I- - ~ - SB 13 8 21.0 (% End of Boring - - WATER LEVEL MEASUREMENTS START 11-26-97 COMPLETE 11-26-97 SAMPLED CASING CAVE-IN WATER METHOD Iii) 11 :55 DATE TIME DEPTH DEPTH DEPTH BAILED DEPTHS LEVEL 3 1/4" HSA to 19 112'. 1-26-9' · 1:25 6' 4.5' 5.2' 4.5' 1.26-9 · 1 :55 21' 19.5' - 14.6' NORTH: EAST: CREW CHIEF R. Mishler MAXIM LOG OF TEST BORING JOB NO. 9754408 VERT I CAL SCALE 1" = 3' But<ING NO. B-2 PROJECT PRIOR IIILLS BUSINESS PARK. PRIOR LAKE. MINNESOTA DEPTH DESCRIPTION OF MATERIAL GEOLOGIC N SAMPLE LABORATORY TESTS IN ,--SURFACE ELEVATION 873.1 or Qu FEET ORIGIN CR \lL NO. TYPE \I D LL PL ~o,rn Fll..L .. mostly lean clay with sand, moist, dark Xx )( Fill 7 1 SB brown Xx >< ~ )( - Xx >< Xx )( ~ )( - ~ >< ~ )( 2 I ~ >< 3 SB - ~ >< ><x ><: ><x x - ~ ><: ~ x ~ ><: 5.5- ><x x - 6 3 SB )( x SANDY CLAY with a trace to a little gravel, moist ~ Glacial - ~ Till - to dry, brown (CL) - ~ ~ 8 4 SB - ~ - - ~ - - 5 I SB 11 - - ~ - ~ ~ 12 6 SB - ~ - ~ - ~ I- 7 SB ~ 10 - ~ - - - ~ - ~ - ~ - 19 8 SB 21.0 ~ End of Boring - \lATER LEVEL MEASUREMENTS START 11-26-97 CCJ4PLETE 11-26-97 SAMPLED CASING CAVE-IN WATER METHOD Ii) 3:15 DATE TIME DEPTH DEPTH DEPTH BAILED DEPTHS LEVEL 3 1/4" HSA to 19 1/2'. 1-26-~ 3:15 21' 19.5' - None NORTH: EAST: CRE\I CHIEF R. Mishler MAXIM LOG OF TEST BORIN\ JOB NO. 9754408 VERTICAL SCALE 1" = 3' BORING NO. B-3 PROJECT PRIOR HILLS BUSINESS PARK. PRIOR LAKE. MINNESOTA DEPTH DESCRIPTION OF MATERIAL ~EOLOGIC N SAMPLE LABORATORY TESTS IN ,--SURFACE ELEVATION 860.6 or Qu FEET ORIGIN CR WL NO. TYPE W D LL PL ROa'"O FILL - mostly lean clay with sand, moist, dark x;< Fill 5 1 SB brown >)(< - >)(< ~ >)(< 'X)(< >< - >l'>< >l'>< >l'>< 4 2 SB - >l'>< ><">< 4.0 ><">< )( SANDY CLA Y with a trace to a little gravel, moist, ~ Glacial brown and brown and gray mottled (CL) Till - - 3 I 4 SB - ~ - - ~ ~ 5 4 SB - ~ - ~ .. ~ - ~ ..- 7 5 SB - ~ ~ ~ ~ I 9 6 [ SB - - - - - - 7 SB ~ 10 - ~ ~ ~ - ~ ~ - ~ - ~ - SB 10 8 21.0 End of Boring - WATER LEVEL MEASUREMENTS START 11-26-97 COMPLETE 11-26-97 SAMPLED CASING CAVE- IN WATER METHOD Ii 9:50 DATE TIME DEPTH DEPTH DEPTH BAILED DEPTHS LEVEL 3 1/4" HSA to 19 112'. 1-28-9' 9:50 21' 19.5' - None NORTH: EAST: CREW CHIEF R. Mishler 1 1 l\tIAXIM LOG OF TEST BORINr JOB NO. 9754408 VERTICAL SCALE 1" = 3' DQRING NO. B-4 PROJECT PRIOR HILLS BUSINESS PARK. PRIOR LAKE. MINNESOTA DEPTH DESCRIPTION OF MATERIAL pEOLOGIC N SAMPLE LABORATORY TESTS IN .--SURFACE ELEVATION 887.3 or Qu FEET ORIGIN CR WL NO. TYPE W D LL PL D~n LEAN CLAY, soft, dark brown (CL) ~ Topsoil 5 1 I SB - 1.5 SILTY SAND, loose, brown and gray (SM) :LJ Coarse - 2.5 ot o. 0 . Alluvium SANDY LEAN CLAY, soft and hard, brown and ~ Glacial 6 2 SB - brown mottled, with lenses and laminations of silty ~ Till sand and sand (eL) ~ - - ~ - ~ 11 3 SB - ~ ~ - ~ i- ~ 10 4 SB - ~ - ~ - ~ I- 13 5 SB . ~ I- ~ - ~ 14 6 I SB - ~ - ~ - - ~ - 7 sa 17 - - - ~ ~ - ~ . ~ ~ - ~ l- S [ SB 22 21.0 ~ End of Boring WATER LEVEL MEASUREMENTS START 11-26-97 COMPLETE 11-26-97 SAMPLED CASING CAVE-IN WATER METHOD Ii 12:35 DATE TIME DEPTH DEPTH DEPTH BAILED DEPTHS lEVEL Continuous saIDplill2 from 0 to 2'. 3 1/4" USA to 1-26-9' 12:35 21' 19.5' - None 19 1/2'. NORTH: EAST: CREW CHIEF T. White MAXIM LOG OF TEST BORINr JOB NO. 9754408 VERT I CAL SCALE 1 II = 3' ouRING NO. B-S PROJECT PRIOR HILLS BUSINESS PARK. PRIOR LAKE. MINNESOTA DEPTH DESCRIPTION OF MATERIAL GEOLOGIC N SAMPLE LABORATORY TESTS IN ~SURFACE ELEVATION 851.4 or Qu FEET ORIGIN CR WL NO. TYPE W D LL PL or Dan ORGANIC LEAN CLAY, moist, dark brown (OL) . . . Topsoil 4 1 I SB . . . . . . 1.0 . . . CLAYEY SAND with a trace of gravel, moist, ~ -.r Glacial ~: brown (SC) ~ ~ Till - - lY. if. ~ -.r 2 I ~ ~ 2 SB - tiI.' ~ - 3.5 j i' 4.0 SILT, moist, brown and gray mottled (ML) I I Fme All. SANDY LEAN CLAY with a trace to a little gravel, ~ Glacial moist, brown and gray mottled to brown (CL) ~ Till ~ - ~ 8 3 SB ~ - ~ ~ 14 4 SB - ~ - ~ ~ - ~ I- 28 S SB - ~ ~ 11.5 ~ CLA YEY SAND with a trace of gravel, moist, )/: ).;1 ~ brown (SC) ;l.~ )~ 20 6 SB ).;1 ;l.~ )~ - ).v. ;l.rI 15.0 ~v. .:; V. - I SB SANDY LEAN CLAY with a little gravel, moist to ~ 16 7 _ dry, gray (CL) ~ - ~ - ~ I- - ~ I- ~ S3 8 SB 21.0 End of Boring - WATER LEVEL MEASUREMENTS START 11-26-97 COMPLETE 11-26-97 SAMPLED CASING CAVE-IN WATER METHOD Ii 12:50 DATE TIME DEPTH DEPTH DEPTH BAILED DEPTHS LEVEL 3 114" HSA to 19 112'. 1-26-9' 12:50 21' 19.5' - None NORTH: EAST: CREW CHIEF R. Mishler MAXIM LOG OF TEST DORINe JOB NO. 9754408 VERTICAL SCALE 1" = 3' But<ING NO. B-6 PROJECT PRIOR HILLS BUSINESS PARK. PRIOR LAKE. MINNESOTA DEPTH DESCRIPTION OF MATERIAL pEOLOGIC N . SAMPLE LABORATORY TESTS IN ~SURFACE ELEVATION 873.8 or Qu FEET ORIGIN CR WL NO. TYPE W D LL PL R~ 0.5 LEAN CLAY, very soft, dark brown (CL) /~ Topsoil 3 1 SB _ SANDY LEAN CLAY, very soft to hard, brown ~ Glacial and brown and dark brown, with a few laminations ~ Till _ of sand and silty sand (CL) ~ ~ 7 2 SB - - ~ ~ - ~ I- ~ 10 3 SB - ~ ~ - ~ ~ ~ 10 4 SB - I- ~ - ~ - - ~ - ~ 21 5 SB - ~ 12.0 - SANDY LEAN CLAY, hard, gray (CL) ~ ~ 27 6 SB - - - ~ - - ~ - 13 7 SB - ~ - - '- ~ - ~ - ~ ~ - ~ - I SB 22 8 21.0 ~ End of Boring - WATER LEVEL MEASUREMENTS START 11-26-97 COMPLETE 11-26-97 SAMPLED CASING CAVE-IN \JATER METHOD 1 al 1:25 DATE TIME DEPTH DEPTH DEPTH BAILED DEPTHS lEVEL Continuous samoliD2 from 0 to 2'. 3 1/4" HSA to 1-26-9 · 1:25 21' 19.5' - None 19 112'. NORTH: EAST: CREW CHIEF T. White MAXIM LOG OF TEST BORIN JOB NO. 9754408 VERT I CAL SCALE 1" = 3' BORING NO. B-' PROJECT PRIOR HnLS BUSINESS PARK. PRIOR LAKE. MINNESOTA DEPTH DESCRIPTION OF MATERIAL ~EOLOGIC N SAMPLE LABORATORY TESTS IN y--SURFACE ELEVATION 869.4 or Qu FEET ORIGIN CR WL NO. TYPE W D LL PL or RQO LEAN CLAY, very soft, black (may be fill) (CL) ~ Topsoil 4 1 SB I - ~ ~ - ~ ~ 4 2 SB ~ ~ ~ 5.0 ~ SANDY LEAN CLAY, very soft to hard, brown ~ Glacial 3 3 SB and brown mottled to gray (CL) ~ Till - ~ ~ - ~ 7 4 I SB - - - - - 10 S SB - - ~ - ~ 13 6 SB - ~ 14.0 ~ SANDY LEAN CLAY, stiff, gray (CL) ~ - ~ ~ 13 7 ( SB ~ - ~ - ~ ~ - ~ - ~ ~ 16 ~ 8 SB 21.0 End of Boring WATER LEVEL MEASUREMENTS START 11-26-97 COMPLETE 11-26-97 SAMPLED CASING CAVE- IN WATER METHOD IQ 2:10 DATE TIME DEPTH DEPTH DEPTH BAILED DEPTHS LEVEL Continuous sampliD2 from 0 to 2'. 3 1/4" HSA to 1-26-' r 2:10 21' 19.5' - None 19 1/2'. NORTH: EAST: CREY CHIEF T. White lVlAXIM S\'1T1bol HSA _FA _HA _DC RC PO CS OM JW sa L T 3TP _TO W -B P -Q X N CR WL 1: NMR SYMBOLS AAD TERl\1INOLOGY ON TEST BORING LOG Drilling and Sampling Description 3-114" I.O. hollow stem auger 4",6" or 10" diameter flight auger 2".4" or 6" hand auger 2-1/2",4",5" or 6" steel drive casing Size A. B or N rotary casing Pipe drill or cleanout tube Continuous split barrel sampling Drilling mud Jetting water 2" 0.0. split barrel sampling 2-1/2" or 3-ln" 0.0. SB liner sample 2" or 3" thin walled tube sample 3" thin walled tube using pitcher sampler 2" or 3" thin walled tube using Osterberg sampler Wash sample Bag sample Test pit sample BQ. NQ, or PQ wireline system AX, BX,or NX double tube barrel Scandard penetration test, blows per foot Core recovery, percent Water level Water level No measurement recorded. primarily due to presence of drilling or coring rluid SThIBOLS Laboratory Testing Symbol Description W Water content, % (ASTM** 02216) o Dry density, pef LL Liquid limit (ASTM 0 4318) PL Plastic limit (ASTM 0 4318) - Inserts in Last Colwnn (Qu or RQD) - Qu Unconfined compressive strength, psi (ASTM 02166) Pq Penetrometer reading, tsf (ASTM 0 1558) Ts Torvane reading, rsf G Specific gravity (ASTM 0 854) SL Shrinkage limits (ASTM 0 427) OC Organic content - Combustion method (ASTM 0 2974) SP Swell pressure, rsf (ASTM 0 4546) PS Percent swell under pressure (ASTM D 4546) FS Free swell, % (ASTM D 4546) SS Shrink swell, % (ASTM D 4546) pH Hydrogen ion content - Meter Method (ASTM D 4972) SC Sulfate content. parts/million or mgl1 CC Chloride content, parts/million or mg/l C* One dimensional consolidation (ASTM D 2435) Qc* Triaxial compression (ASTM D 2850 and 0 4767) O.S. * Direct shear (ASTM D 3080) K* Coefficient of permeability, cm/sec (ASTM 0 2434) P* Pinhole test (ASTM 0 4647) - DH* Double hydrometer (ASTM 0 4221) ~Lo\ * Particle size analysis (ASTM 0 422) R Laboratory electrical resistivity, ohm-cm (ASTM G 57) E. Pressuremeter deformation modulus. rsf (ASTM D 4719) PM. Pressuremeter test (ASTM 0 4719) VS. Field vane shear (ASTM 0 2573) IR * Infiltrometer tcst (ASTM 0 3385) RQD Rock quality designation, percent · Resulrs shown on act:lcbed data sheet or graph .. ASTM designates American Society for Testing and Materials TER"IINOLOGY Particle Sizes Soil Layering and ~loisture Tvpe Size RanS!e Tenn Visual Observation Boulders > 12" Lamination Up to 1/4" thick stratum Cobbles 3. - 12" Varied Alternating laminations of any combination of clay, Coarse gravel 3/""" - 3" silt. fin:: sand, or colors Fine gravel #~ sieve - 3/4" Lenses Small pockets of different soils in a soil mass Coarse sand #4 - #10 sieve Stracified Alternating layers of varying materials or colors Medium sand #10 - #J,O sieve Layer 1/4" to 12" thick Stratum Fine sand ;lJ,0 - #~oo sieve Dry Powdery, no noticeable water Silt 100% passing #200 sieve and> 0.005 mm Moist Damp, below saruration Clay 100% passing #200 sieve and < 0.005 mm Watcrbeanng Pervious soil below water Wet Saturated. above liquid limit Gravel Content Standard Penetration Resistance Coarse-Grained Soils Fine-Grained Soils Cohesion less Soils Cohesive Soils 0/0 Gr3,.cl Description % Gravel Description ~ Relatiye Density ~ Consistenc,' 2 - 15 A little gravel < 5 Trace of gravel 0-4 Very loose 0-4 Very soft 16 - 49 \Vilh gravel 5 - 15 A litue gravel 5 - 10 Loose 5 - 8 Soft 16 - 30 With gravd II - 30 Medium dense 9 - 15 Firnl 3 1 - 49 Gr.welly J 1 - 50 Dense 16 - 30 Hard > 50 Very dense > 30 Very Hard I MAXIM I FIELD EXPLORATION PROCEDURES Soil S~mpline Soil sampling was performed in accordance with ASTM:D1586-92. Using this procedure, a 2" O.D. split barrel sampler is driven into the soil by a 140 lb weight falling 30". After an initial set of 6", the number of blows required to drive the sampler an additional 12" is known as the penetration resistance or N value. The N value is an index of the relative density of cohesionless soils and the consistency of cohesive soils. Thin wall tube samples were obtained according to ASTM:D1587-94 where indicated by appropriate symbol on the boring logs. Rock core samples, if taken, were obtained by rotary drilling in accordance with ASTM:D2113-93. Power auger borings, if performed, were done in general accordance with ASTM:D1452-90. Soil CI~~~ifir~tinn As the samples were obtained in the field, they were visually and manually classified by the crew chief in accordance with ASTM:D2488-93: Representative portions of the samples were then rettJrned to the laboratory for further examination and for verification of the field classification. Logs of the borings indicating the depth and identification of the various strata, the N value, the laboratory test data, water level information and pertinent information regarding the method of maintaining and advancing the drill holes are attached. The descriptive terminology and symbols used on the boring logs are also attached. MAXIM APPENDIX B CONSTRUCTION OBSERVATIONS AND TESTING PRECAUTIONS FOR EXCAVATING AND REFILLING DURING COLD WEATHER MAXIM CONSTRUCTION OBSERVATIONS Ai'ID TESTING The recommendations made in this report have been made based on the subsurface conditions found in the borings. It is possible that there are soil and water conditions on site that were not represented by those borings. Consequently, on-site observation during construction is considered integral to the successful implementation of the recommendations. We believe that qualified field personnel need to be on site at the following times to observe the site conditions and effectiveness of the construction. We recommend that the completed excavation and prepared sub grade be observed and tested by a soils engineer/technician prior to fill placement or construction of any foundation elements. These observations would" be necessary to judge if all unsuitable materials have been removed from within the planned construction area and that an appropriate degree of lateral oversize has been provided for in those areas where f111 will be placed below the bottom of foundation grade. We recommend a representative numb~r of field density tests be taken in all engineered fill placed to aid in judging its suitability. We suggest that at least one density test be' performed for at least every 2500 square feet of engineered fill placed for every 2' of fill depth. . Additional tests should be taken w~ere confmed areas are compacted. Any proposed f111 material should be submitted to the laboratory for tests to check compliance with our recommendations and project specifications. MAXIM PRECAUfIONS FOR EXCAVATlNG A1'ID REFILLING DURING COLD \VEATHER The winter season in this area presents specific problems for foundation construction. Soils which are allowed to freeze undergo a moisture volume expansion, resulting in loss of density. These frost-expanded soils will consolidate upon thawing, causing settlement of any structure supported on them. To prevent this settlement, frost should not be allowed to penetration into the soils below any proposed structure. Ideally, winter excavation should be limited to areas small enough to be refIlled to grade higher than footing grade on the same day. Typically, these areas should be filled to floor grade. Trenching back down to unfrozen soils for foundation constrU~tion can then be performed just prior to footing placement. The excavated trenches should be protected from freezing by means of insulating or heating during foundation construction. Backfilling of the foundation trenches should be performed immediately after the below-grade foundation construction is fmished. In addition, any interior footings or footings designed without frost protection should be extended below frost depth, unless adequate precautions are taken to prevent frost intrusion until the building can be enclosed and heated. In many cases, fmal grade cannot be attained in one day's time, even though small areas are worked. In the event fmal grade cannot be attained in one day's time, frost can be expected to develop overnight. The depth of frost penetration can be minimized by leaving a layer of loose soil on top of the compacted material overnight. However, any frost which forms in this loose layer, or snow which accumulates, should be completely removed from the flil area prior to compaction and additional soil placement. Frozen soils, or soils containing frozen material or snow should never be used as flil material. After the structure has been enclosed, all floor slab areas should be subjected to ample periods of heating to allow thawing of the soil system. Alternatively, the frozen soil can be completely removed and be replaced with an engineered fill. The floor slab areas should be checked at random and representative locations for remnant areas of frost, and density tests should be performed to document fill compaction prior to slab placement. Due to the potential problems associated with fill placement during cold weather, any filling operations should be monitored by a full-time, on-site soils technician. Full-time monitoring aids in detecting areas of frozen material, or potential problems with frozen material within the fill, so that appropriate measures can be taken. The choice of fill material is particularly important during cold weather, since clean granular fill materials can be placed and compacted more efficiently than silty or clayey soils. In addition, greater magnitudes of heaving can be expected with freezing of the more frost susceptible silts and clays. If more specific frost information or cold weather data concerning other construction materials is required, please contact us. MAX/A1 APPENDIX C INTERPRETING A GEOTECHNICAL ENGINEERING REPORT MAXIM AS the client of a consulting geotechnical engineer. you should know that site subsurface conditions cause more construction problems than any other factor. ASFElfhe Association of Engineering Firms Practicing in the Geosciences offers the following suggestions and observations to help you manage your risks. A GEOTECHNICAL ENGINEERING REPORT IS BASED ON A UNIQUE SET OF PROJECT-SPECIFIC FACTORS Your geotechnical engineering report is based on a subsurface exploration plan designed to consider a unique set o( project-specific (actors. These factors typically indude: the general nature of the structure involved. its size. and configuration: the location of the structure on the site: other improvements. such as access roads. parking lots. and underground utilities; and the additional risk created by scope-of-service limitations imposed by the client. To help avoid costly problems. ask your geotechnical engineer to evaluate how factors that change subsequent to the date of the report may affect the report'S recommendations. Unless your geotechnical engineer indicates otherwise. do not use your geotechnical engineering report: . · when the nature of the proposed structure is changed. for example. if an office building will be erected instead of a parking garage. or a refrigerated warehouse will be built instead of an unrefrigerated one: when the size. elevation. or configuration of the proposed structure is altered; · when the localion or orientation of the proposed structure is modified; · when there is a change of ownership; or · for application to an adjacent site. Geotechnical engineers cannot accept responsibility for problems that may occur if they are not consulted after factors considered in their report"s development have changed. SUBSURFACE CONDITIONS CAN CHANGE A geotechnical engineering report is based on condi- tions that existed at the time of subsurface exploration. Do not base construction decisions on a geotechnical engineering report whose adequacy may have been affected by time. Speak with your geotechnical consult- ant to learn if additional tests are advisable before construction starts. Note. too. that additional tests may be required when subsurface conditions are affected by construction operations at or adjacent to the site. or by natural events such as floods. earthquakes. or ground water fluctuations. Keep your geotechnical consultant apprised of any such events. .' MOST GEOTECHNICAL FINDINGS ARE PROFESSIONAL JUDGMENTS Site exploration identifies actual subsurface conditions only at those points where samples are taken. The data were extrapolated by your geotechnical engineer who then appli~d judgment to render an opinion about overall subsurface conditions. The actual interface between materials may be far more gradual or abrupt than your report indicates. Actual conditions in areas not sampled may differ from those predicted in your report. While nothing can be done to prevent such situations. you and your geotechnical engineer can work together to help minimize their impact. Retaining your geotechnical engineer to observe construction can be particularly beneficial in this respect. A REPORT'S RECOMMENDATIONS CAN ONLY BE PRELIMINARY The constrl,lction recommendations included in your geotechnical engineer's report are preliminary. because they must be based on the assumption that conditions revealed through selective exploratory sampling are indicative of actual conditions throughout a site. Because actual subsurface conditions can be discerned only during earthwork. you should retain your geo- technical engineer to observe actual conditions and to finalize recommendations. Only the geotechnical engineer who prepared the report is fully familiar with the background information needed to determine whether or not the re~rt's recommendations are valid and whether or not the contractor is abiding byappli- cable recOr:1mendations. The geotechnical engineer who developeC your report cannot assume responsibility or liability fOf the adequacy of the report's recommenda- tions if anc.ther party is retained to observe construction. GEOTECH:\ICAL SERVICES ARE PERFORMED FOR SPECIFIC PURPOSES AND PERSONS Consulting geotechnical engineers prepare reports to meet the specific needs of specific individuals. A report prepared for a civil engineer may not be adequate for a construction contractor or even another civil engineer. Unless indicated other\vise. your geotechnical engineer prepared your report expressly for you and expressly for purposes you indicated. No one other than you should apply this report for its intended purpose without first conferring with the geotechnical engineer. No party should apply this report for any purpose other than that originally contemplated without first conferring with the geotechnical engineer. CEOENvmONMENTAL CONCERNS ARE NOT AT ISSUE Your geo[-e.:hnical eng'rleerin~ repOrl is nOll1kely to relate any t!r.dings. conclusions. or recommendations about the potential for hazardous materials existing at the site. The equipment. techniques. and personnel used to perform a geoenvironmental exploration differ substantially from those applied in geotechnical engineering. Contamination can create major risks. If you have no information about the potential for your site being contaminated. you are advised to speak with your geotechnical consultant for information relating to geoenvironmental issues. A GEOTECHNICAL ENGINEERING REPORT IS SUBJECT TO MISINTERPRETATION Costly problems can occur when other design profes- sionals develop their plans based on misinterpretations of a geotechnical engineering report. To help avoid misinterpretations. retain your geotechnical engineer to work with other project design professionals who are affected by the geotechnical report. Have your geotech- nical engineer explain report implications to design professionals affected by them. and then review those design professionals' plans and specifications to see how they have incorporated geotechnical factors. Although certain other design professionals may be fam- iliar with geotechnical concerns. none knows as much about them as a competent geotechnical engineer. BORING LOGS SHOULD NOT BE SEPARATED FROM THE REPORT . Geotechnical engineers develop final boring logs based upon their interpretation of the field logs (assembled by site personnel I and laboratory evaluation of field samples. Geotechnical engineers customarily include only final boring logs in their reports. Final boring logs should not under any circumstances be redrawn for inclusion in architectural or other design drawings. because drafters may commit errors or omissions in the transfer process. Although photographic reproduction eliminates this problem. it does nothing to minimize the possibility of contractors misinterpreting the logs during bid preparation When this occurs. delays. disputes. and unanticipated costs are the all-too-frequent result. To minimize the likelihood of boring log misinterpreta- tion. give contractors ready access to the complete geotechnical engineering report prepared or authorized for their use. (If access is provided only to the report prepared for you. you should advise contractors of the report's limitations. assuming that a contractor was not one of the specific persons for whom the report was prepared and that developing construction cost esti- mates was not one of the specific purposes for which it was prepared. In other words. while a contractor may gain important knowledge from a report prepared for another party. the contractor would be well-advised to discuss the report with your geotechnical engineer and to perform the additional or alternative work that the contractor believes may be needed to obtain the data specifically appropriate for construction cost estimating purposes.) Some clients believe that it is unwise or unnecessary to give contractors access to their geo- technical engineering reports because they hold the mistaken impression that simply disclaiming responsi- bility for the accuracy of subsurface information always insulates them from attendant liability. Providing the best available information to contractors helps prevent costly construction problems. It also helps reduce the adversarial attitudes that can aggravate problems to disproportionate scale. READ RESPONSIBILITY CLAUSES CLOSELY Because geotechnical engineering is based extenSively on judgment and opinion. it is far less exact than other design disciplines. This situation has resulted in wholly unwarraoted claims being lodged against geotechnical engineers. To help prevent this problem. geotechnical engineers have developed a number of clauses for use in their contracts. reports. and other documents. Responsi- bility clauses are not exculpatory clauses designed to transfer geotechnical engineers' liabilities to other parties. Instead. they are definitive clauses that identify where geotechnical engineers' responsibilities begin and end. Their use helps all parties invol\'ed recognize their individual responsibilities and take appropriate action. Some of these definitive clauses are likely to appear in your geotechnical engineering report. Read them closely: Your geotechnical engineer will be pleased to give full and frank answers to any questions. RELY ON THE GEOTECHNICAL ENGINEER FOR ADDITIONAL ASSISTANCE Most ASFE-member consulting geotechnical engineer- ing firms are familiar with a variety of techniques and approaches that can be used to help reduce risks for all parties to a construction project. from design through construction. Speak with your geotechnical engineer not only about geotechnical issues. but others as well. to learn about approaches that may be of genuine benefit. You may also wish to obtain certain ASFE publications. Contact a member of ASFE of ASFE for a complimentary directory of ASFE publications. ASFE PROFESSIONAL FIRMS PRACTICING IN THE GEOSCIENCES 8811 COLESVILLE ROADISUITE GI06lSILVER SPRING. MD 20910 TELEPHONE: 301/565-2733 FACSIMILE: 301/589-201 i Copyright I<N2 by ASFE. Inc Unless ASFE grants specific permission to do so. duplication of thiS document by cir: :7Ieans whats~.t: is expressly prohibited. Re.uc;e of the wareing In thiS document. in whole or in part. also is expressly prohibited. and ma~' be done only with t:"e eApress perr.".:H'~n o( ASFE or (or purposes o( review or scholarly research Bf'CQ';Q2A11 ';~, -e... ST~(.., , ~,~ \ \ \ ' \ ? ~.:; T tYl ,;;;J'-'f I ~ / 2: Si?A-c I/U ~ .-- CJ. , <-. Feu'L P....;&t;-I C . ~I/~ Sr+\ S - l I 4 i 3 (LA-( L-S ~SoQ ps l~ FNO ~ MASf8L- L~CAT lar--l ~p. S"A;'I"'\..~e-- t=. \) ~ ~N~ ,(c..\"J. 1\.,,"^""-sIL- \0 C,o.LL.-ULA-\-&- ~ ~ SU:'S. ~ M~ lcx.--A-\I5O? ill t NDlCATE- VU(~ . DErAIl- "'~~"':. :;~;:~~1Aln... S, INC-. fC-t5E l<UN (-\,A.N D f2.A 1 '- ~ I S P/^'@t ~ ~C2~\. l..,o..No'~ .~ ~~-\'2- "Z.I ~~ ~ .:f"'l" J~ LENc..~H UB~ lOC;)~. 3. '.1 sttEEr C"'3 ~oC>.=- ~V\~.. CoMt=><s"t"E 6~;>/V'-rLOA,{)> ~ b'T1~KE~ {,..t C> tc-~ ; OCc..~A r"1 S'- t t....J~-+~ (J ? ft--r- A \'" \ ~'tE , ~ ~.s 2-0\ .~ 1..02 (:;!- t~ tvt...c;r- ge- L~ ~ \ o~ ~ i;)ooclL~ lOf) AI\.JC) (01 oV~ '!-z... DrA ~Oc> ~r(\ll~1~. .. S~ A\.' u ~c.. ~ ~ . ! (2c.V{~O~c. (Da+.Z. L.. Er'-?4- focr4. ~ CA~l SOL;' ~~.~ 1/(,)" p ?~r ^ \ . l '. (\ 7 \ S ,,1-; ~ ~ U ~~ O(? A,.a.. U.....oC'{\..., ::>i)A. I~ S . \l Be. lo"S:Si ~AI'- '1/A '!>., 'f'[l..o\J(OG-' k )/ t N \"-0. '_ f)~ ~ \. ~ , l t-'t>U:'Ar-to u ~14 ~ M4;~'A"""S. ~ G:V\.8WWC \ ,..r-'. . ~t+r. A.<( INDIC^~ (CAe. c?LA'7':> ~".>N~ [, M<::f+ne<:--T. ~ ~ Jot~Sa-J . L,-r"? i2~Vi~~.j. \L 0 1/ -J i. V' ~. ,-". l ~'?"_"_HI.. f- . I I <:' ~~. H. .....-- . G6r: e, I ~I €?(. \ A;, ~ (-tec-.'~'S-/ iJ"'-' > \f) '. t.'Jt9 . - . ~:"';:vv..,"' '[]7r' c2. S. f? #~.,- /I~ vc- ar/JIL - 1ki?,.u<t'L- - 4 ~j~~-7f~?'" A:>i.i.-.f ~.( ~s Z 0.' / $.cc ,<.r'lC/~!' /1.€("- T/fE SJ'/G.4GIL'; er~,f ,1:h.zs .' Ft.Ai ? ~ ,00 T/rt'6'1 Go /f~")(;"f::' /2/j "J"'"I/-:J~~,~.' / I t i -.l ~~2 ;<<;2 S () A-q:=" <: (y r, r. ) /), ./) ( ,~~ AI S-.,j{ (/ G~I 51 TE loc-Are AT NdLTH.$M'()~ uJES,- T~. 6; 5 I Ayv. "IE {::'-'c~",,,,,,,,,,,,./\-- '~p ;~ { .:;'~i-.J /00 s. 3-_ 'S If<-c rA /L 'l ; +- I !~ ;! L/1N]'~ ~ (27 Ifi.!:o, 6tf 44" (N ~Oi" U/5G/"03.-3,/.1 (;~(Nt,zl)/':A'; e t& r~~ - 7e>~~>: WAl-L- ! S/~ cS Ccm/'tfTE a:-.c.u,PAIoIVj ~5 /M/.tJ e;<'t'r/Nb k1:;~~ " II ~ C-a>6- ,k!.e-/lf~ A. i..U~ ~AIf/ 5-/ A /,,/ I lAde, fho,e~ -10/ ~ toZ M. ..,., ,. A' / lL.-1...>-H I _. f' f (),[., 'q c...(I.f....... i .! .. . , f'. , ! ,~) '. . (., "'" i" r i'? f'o-. !}1 (,.., S 'r t) t. I/... /2 ,.<) ,. ]J2 f,. ,,-,f~) ~ L ...-' .,- I'h r;,;;" I . ki: ill L C.I,~J I<:! f~ !~) f '" I / C) CK~. 10"( /)::.l"-, \ No l-- ; . '.' ." :> j f,.r/~ .f J u.1 H .... 4. .. . 11 If L ,U9 '7 CWl tc C.' ::. I ,~) r Mt.. ;"CT C,-" .~I;.~ I'J' /-::J/2. (O(..~ UdC. r~ /"1 (. 7""" C.J u Dtl Ir:;r A O,i2. lID A ! . i -:r4Ar----LAJ.,~......d:J.~_., -........ i Ai) ~s u8c (0 . ~. 3. ~ u')C::: '-.i"- Hr;s~"~ 'jY~';,:;~S 70,)f~~~;2:X>~ ~~~4I;f,/14(c1 ~/A 3, I Zi_rO i' iJ//11 <7/1..;./",,1 ISG' r~'~ ~()~qG S.pti.q~ VCe:- iO()5. '3 ,_ ~. ~ 4' ;: ///1<1-0/2/1 ;):.7r't..- Iii TO f OF Srn'/iZ s 41~8C. '3"11~___ I I, O.F ;')6A{<- ,~i&J~P~~ WOrl11&JS{ /)10 A-u.. FiJI'{' Pmf2 !.kQllt!>~""> I~ t/!JlP /tOfJ{$> 1\J.h?1~5 i (1 f /()E/VY( Pf t/r#J.vA/-ff oN fire fAr&p!h:i<-s i V Sr iL-' G, l~ , Foo,>,V'& {,f.!<-';o5 .c;,&/rc."J s. \. f C71~ cif' ;4-1- E>i>r. 5rr1rfl-tS ~ .f b-fJ0 )~jV\ [1 f4?(JVlCO ~ -)N. 5/3D/b \ u Memorandum DATE: April 17, 2000 TO: Jane Kansier FROM: Robert D. Hutchins RE: Wensco, Inc. Office/Showroom Following are the results of the preliminary plan review for the Wensco, Inc. Office/Showroom. Our review was based on the Minnesota State Building Code (MSBC) which adopted with amendments the 1997 Uniform Building Code (UBC) with handicap regulations of the Minnesota Accessibility Code Chapter 1341 and with requirements of the 1998 Minnesota State Fire Code (MSFC) which adopted with amendments the 1997 Uniform Fire Code (UFC). The comments are numbered as in the December 19, 1999 plan review letter. /" '/' / ~bmit signed architectural, struc~al, site, and utility plans. v-' Il-~\::> /2. Submit mechanical, plumbing, fire alarm, and sprinkler plans. May be submitted at a (;;> <.." ) later date. QJsubmit a soils report. (J. Provide the Illumination Budget Calculation Summary, MN Energy Code Part 7670.080. @rhe proposed warehouses have no occupancy separation provisions to store or drive motorized vehicles into any area. Provide a letter stating that "Motorized vehicles other than electronically driven, will not be driven or stored in the building." @ubmit Energy Envelope Calculations. C)A S.A.C. determination must be completed by the Metropolitan Waste Control Commission. Contact Jody Edwards at 651.602.1113. @Ubmit the Structural Engineers requirements for Special Inspections UBC 1701.5. See enclosed. W' ,# ~. Separate tenant finish permits required for each tenant space. b~ @I. At least one of the HDCP parking stalls must be a van HDCP parking stall. MSBC 1341.0403 Subpart E subitem 2. IN v (c.--A'~ 5lbN ~~ . G~~2. Ventilation for the building must meet UBC Chapter 12. Provide 15 CFM of l,A./<'--v"""- ventilation air per occupant. ~ Provide fire lanes for fire apparatus response. Signage to read :" No Parking Fire Lane by order of Fire Department". Locate by Fire Hydrants and by Siamese connection. UFC 1001.7.1. ~ 4. In-rack sprinklers, early suppression fast response sprinklers or an other approved uJlLt'" / system that meets the National Fire Protection Association (NFPA) section 231c is ((J~ ~ ~ required for all storage areas where the top of the pile storage is over 12 feet above the tJf(L( poor or grade. iI Provide fire extinguishers minimum 2A10BC rated, within 75 feet travel distance of all areas. UFC 1002. @Provide exit signs at exit doors. UBC 1003.2.8.2. ~. Provide a racking and equipment layout. U( g 8 Provide emergency lighting. At the time of rack installation, a final determination will ( l) I ~ , ,-(4\ be made as to the visibility of exit pathways. \{\S~r-J / ~f'\( '10. Provide a recycling space. MSBC 1300.4700. ~u "- Automatic garage doors to comply with State of Minnesota Statutes. MSBC 1300.5900 J. Lighting Store: The second floor does not meet definition of a mezzanine. UBC 507. ~Lighting Store: Two exits from second floor office. UBC 1004.2.3.2. One of the exits must exit into a corridor that provides direct access to an exit. UBC 1004.2.2 Exception 4. The following are an additional comment: ~. Provide drinking fountains in each tenant unit. UBC Appendix Table 29-A This is a preliminary review only. Other code items will be addressed when the final plans are submitted. The building plans must be reviewed by the Cites Developmental Review Committee (ORC) which consists of representatives of Planning, Engineering, Parks, Finance, and Building Departments. The DRC must approve the plans before a building permits can be issued. 2 -, -- MAY302Wl , Date Receiv:~l-----=~__~__~~ (Reviewed PE~Em----) Date: Request: Date: Request: Date: Request: Date: Request: Date: Reply: Date: Reply: Date: Reply: Date: Reply: Build ing/Plann ing/Eng ineeri ng Permit Complete 0 PERMREQU.DOC Permit# _ REPLY DATE Accept 0 Decline 0 Accept 0 Decline 0 Accept D Decline D Accept 0 Decline 0 Permit Issued D ~/231(x) CITY OF PRIOR LAKE BUILDING INSPECTION DEPARTMENT COMMERCIAL & MULTI-UNIT PLAN REVIEW CHECKLIST W E.NS ~ Project Name: Job Address: ~f\..t.f"A (^-' I 'l ( l...'- ".:, U (2.. . I. CLASSIFICATION OF BUILDING: A. Use of Building !'~/'Z4 (2) 400 1. Occupancy Group (Table 5-1) n f~ s- ( 2. Occupancy Separations (Table 5-B) -e- B. Type of Construction (Table 5-A) I - N C. Location of Property , 'I Front {pO 4 Rear l&,O' ( L. Side &f:) i R. Side ~ 0 t D. Floor Area 1. Actual? Z .~z-4- 2. Allowable (Table 5-C) \ 1-CX:::>o 3. Area Increase a) Open Area (505) \'2. ~,< k.:):,=,r~ ~ 'L4~ b) Sprinkler (505.3) 2. ~OQ:?)( 'CD 10 -- 453 00 0 c) Multi-Story (506) l\.~ x'l.:. 9. (0 000 4. Mixed Occupancy Calculation = ~ E. Height and Number of Stories 1. '+ Height 15 - Allowable (Table 5-D): Stories 1-, Height Allowable Increase ~ f[ , 40 Actual: Stories 2. 3. Memorandum DATE: April 17, 2000 TO: Jane Kansier ~\)\js FROM: Robert D. Hutchins RE: Wensco, Inc. Office/Showroom Following are the results of the preliminary plan review for the Wensco, Inc. Office/Showroom. Our review was based on the Minnesota State Building Code (MSBC) which adopted with amendments the 1997 Uniform Building Code (UBC) with handicap regulations of the Minnesota Accessibility Code Chapter 1341 and with requirements of the 1998 Minnesota State Fire Code (MSFC) which adopted with amendments the 1997 Uniform Fire Code (UFC). The comments are numbered as in the December 19, 1999 plan review letter. / / 1. Submit signed archi\lc~~ stte. and utility plans. 2. Su~ mechanical, plumbing, fire alarm, and sprinkler plans. May be submitted at a later date. ~.(. (j Submit a soils report. 0.(. 6Jprovide the Illumination Budget Calculation Summary, MN Energy Code Part 7670.080. ~ .f. Q)rhe proposed warehouses have no occupancy separation provisions to store or drive motorized vehicles into any area. Provide a letter stating that "Motorized vehicles other than electronically driven, will not be driven or stored in the building." ~ .? ~ubmit Energy Envelope Calculations. ~.Q. (jJ A S.A.C. determination must be completed by the Metropolitan Waste Control Commission. Contact lady Edwards at 651.602.1113. {S.( . (j)Submit the Structural Engineers requirements for Special Inspections UBC 1701.5. See enclosed. '7 ~ ? G)eparate tenant finish permits required for each tenant space. 11 At least one of the HDCP parking stalls must be a van HDCP parking stall. MSBC 1341.0403 Subpart E subitem 2. ol'f<>\J'Db S;\ o,vAc....6 ~N '-5. ( ,. e.i..@?Ventilation for the building must meet UBC Chapter 12. Provide 15 CFM of (Y' ~ ventilation air per occupant. vi. Provide fire lanes for fire apparatus response. Signage to read:" No Parking Fire Lane by order of Fire Department". Locate by Fire Hydrants and by Siamese connection. UFC 1001.7.1. It-; .2. ~-rack sprinklers, early suppression fast response sprinklers or an other approved r (.J{t-,;CI'" system that meets the National Fire Protection Association (NFP A) section 231c is \9('> required for all storage areas where the top of the pile storage is over 12 feet above the floor or grade. -Is. Provide fire extinguishers minimum 2AI0BC rated, within 75 feet travel distance of all areas. UFC 1002. (16) Provide exit signs at exit doors. UBC 1003.2.8.2. \ _._._f 17. Provide a racking and equipment layout. 18. Provide emergency lighting. At the time of rack installation, a final determination will jJe made as to the visibility of exit pathways. \t6. Provide a recycling space. MSBC 1300.4700. ~omatic garage doors to comply with State of Minnesota Statutes. MSBC 1300.5900 Lo&>~6J. f-1f'I^l- ~. Lighting Store: The second floor does not meet definition of a mezzanine. UBC 507. ~ Lighting Store: Two exits from second floor office. UBC 1004.2.3.2. One of the exits must exit into a corridor that provides direct access to an exit. UBC 1004.2.2 Exception 4. The following are an additional comment: ~ 1. Provide drinking fountains in each tenant unit. UBC Appendix Table 29-A This is a preliminary review only. Other code items will be addressed when the final plans are submitted. The building plans must be reviewed by the Cites Developmental Review Committee (DRC) which consists of representatives of Planning, Engineering, Parks, Finance, and Building Departments. The DRC must approve the plans before a building permits can be issued. 2 Memorandum DATE: April 17, 2000 TO: Jane Kansier ~\)\)s FROM: Robert D. Hutchins RE: Wensco, Inc. Office/Showroom Following are the results of the preliminary plan review for the Wensco, Inc. Office/Showroom. Our review was based on the Minnesota State Building Code (MSBC) which adopted with amendments the 1997 Uniform Building Code (UBC) with handicap regulations of the Minnesota Accessibility Code Chapter 1341 and with requirements of the 1998 Minnesota State Fire Code (MSFC) which adopted with amendments the 1997 Uniform Fire Code (UFC). The comments are numbered as in the December 19, 1999 plan review letter. 1. Submit signed architectural, structural, site, and utility plans. 2. Submit mechanical, plumbing, fire alarm, and sprinkler plans. May be submitted at a later date. 3. Submit a soils report. 4. Provide the Illumination Budget Calculation Summary, MN Energy Code Part 7670.080. 5. The proposed warehouses have no occupancy separation provisions to store or drive motorized vehicles into any area. Provide a letter stating that "Motorized vehicles other than electronically driven, will not be driven or stored in the building." 6. Submit Energy Envelope Calculations. 7. A S.A.C. determination must be completed by the Metropolitan Waste Control Commission. Contact Jody Edwards at 651.602.1113. 8. Submit the Structural Engineers requirements for Special Inspections UBC 1701.5. See enclosed. 9. Separate tenant finish permits required for each tenant space. 11. At least one of the HDCP parking stalls must be a van HDCP parking stall. MSBC 1341.0403 Subpart E subitem 2. 12. Ventilation for the building must meet UBC Chapter 12. Provide 15 CFM of ventilation air per occupant. 13. Provide fire lanes for fire apparatus response. Signage to read :" No Parking Fire Lane by order of Fire Department". Locate by Fire Hydrants and by Siamese connection. UFC 1001.7.1. 14. In-rack sprinklers, early suppression fast response sprinklers or an other approved system that meets the National Fire Protection Association (NFP A) section 231c is required for all storage areas where the top of the pile storage is over 12 feet above the floor or grade. 15. Provide fire extinguishers minimum 2A10BC rated, within 75 feet travel distance of all areas. UFC 1002. 16. Provide exit signs at exit doors. UBC 1003.2.8.2. 17. Provide a racking and equipment layout. 18. Provide emergency lighting. At the time of rack installation, a final determination will be made as to the visibility of exit pathways. 20. Provide a recycling space. MSBC 1300.4700. 21. Automatic garage doors to comply with State of Minnesota Statutes. MSBC 1300.5900 23. Lighting Store: The second floor does not meet definition of a mezzanine. UBC 507. 24. Lighting Store: Two exits from second floor office. UBC 1004.2.3.2. One of the exits must exit into a corridor that provides direct access to an exit. UBC 1004.2.2 Exception 4. The following are an additional comment: 31. Provide drinking fountains in each tenant unit. UBC Appendix Table 29-A This is a preliminary review only. Other code items will be addressed when the final plans are submitted. The building plans must be reviewed by the Cites Developmental Review Committee (DRC) which consists of representatives of Planning, Engineering, Parks, Finance, and Building Departments. The DRC must approve the plans before a building permits can be issued. 2 (f;! -' 4J') ,. ....')~., ..~. Memorandum DATE: December 29,1999 TO: Jane Kansier FROM: Robert D. Hutchins {W~ RE: Wensco, Inc. Office/Showroom Following are the results of the preliminary plan review for the Wensco, Inc. Office/Showroom. Our review was based on the Minnesota State Building Code (MSBC) which adopted with amendments the 1997 Uniform Building Code (UBC) with handicap regulations of the Minnesota Accessibility Code Chapter 1341 and with requirements of the 1998 Minnesota State Fire Code (MSFC) which adopted with amendments the 1997 Uniform Fire Code (UFC). 1. Submit signed architectural, structural, site, and utility plans. 2. Submit mechanical, plumbing, fire alarm, and sprinkler plans. May be submitted at a later date. 3. Submit a soils report. 4. Provide the Illumination Budget Calculation Summary, MN Energy Code Part 7670.080. 5. The proposed warehouses have no occupancy separation provisions to store or drive motorized vehicles into any area. Provide a letter stating that "Motorized yehicles other than electronically driven, will not be driven or stored in the building." 6. Submit Energy Envelope Calculations. 7. A S.A.C. determination must be completed by the Metropolitan Waste Control Commission. Contact Jody Edwards at 651.602.1113. 8. Submit the Structural Engineers requirements for Special Inspections UBC 1701.5. See enclosed. 9. Separate tenant fInish permits required for each tenant space. ,. Provide three HDCP onsite parking stalls that shall be located on the shortest possible route to the entrance to the building. MSBC 1341.0403 and 1341.0428 Subpart 2. 11. At least one of the HDCP parking stalls must be a van HDCP parking stall. MSBC 1341.0403 Subpart E subitem 2. f(n({)] 12. Ventilation for the building must meet UBC Chapter 12. Provide 15 CFM of ventilation air per occupant. 13. Provide fire lanes for fire apparatus response . ead :" No Parking Fire Lane by order of Fires D. ...._~:LO._. ocate. by FIfe Hydrants an oy:'~ian11 ection. UFC 1001 7.1.- A-$~ i&'#\. ~ PIVS f S;,~~~, ~ pt4VNf r.O. ~ e. ,,6:;6- (;at:Jjl/N6"'Tlc:iI.. 14. In-rack sprinklers, earlY-suppression fast response sprinklers or an other approved system that meets the National Fire Protection Association (NFP A) section 231 c is required for all storage areas where the top of the pile storage is over 12 feet above the floor or grade. 15. Provide fire extinguishers minimum 2A10BC rated, within 75 feet travel distance of all areas. UFC 1002. 16. Provide exit signs at exit doors. UBC 1003.2.8.2. 17. Provide a racking and equipment layout. 18. Provide emergency lighting. At the time of rack installation, a final determination will be made as to the visibility of exit pathways. ~. Provide two parking spaces for commuter van. MSBC 1300.4100. 20. Provide a recycling space. MSBC 1300.4700. 21. Automatic garage doors to comply with State of Minnesota Statutes. MSBC 1300.5900 -6:-Lighting Store: East Exterior door to swing out. UBC 1003.3.3.1.5. 23. Lighting Store: The second floor does not meet definition of a mezz~anme. . . --_._~~ ~. Lighting Store: Two exits from second floor office. UBC 1004.2.3.2- ~~ /~ ~~ ATS/J16>.6JfJtJf/<.C- . \ ;J6. Lighting Store: Provide an elevator to second floor office. MSBC 134"t:-04Q5 Item E ___/ Exception 1 Subitem 4. t/#~30~#r5 - ~. Appliance Showroom: Male and Female lavatories required. UBC Table A-29-A. JIf. Appliance Showroom: Swing West Exterior door out. UBC 1003.3.3.1.5. ~ Flooring Store: Change in floor elevation shall be by ramps. UBC 1003.2.6. 1'- Roof top equipment musrbe lS~~ sft:;: ~q 1300.4500. J6. Dock Stairs require handrails. UBC 1003.3.3.6. This is a preliminary review only. Other code items will be addressed when the final plans are submitted. The building plans must be reviewed by the Cites Developmental Review Committee (ORC) which consists of representatives of Planning, Engineering, Parks, Finance, and Building Departments. The DRC must approve the plans before a building permits can be issued. r- r;~ S 2 CITY OF PRIOR LAKE BUILDING INSPECTION DEPARTMENT COMMERCIAL & MULTI-UNIT PLAN REVIEW CHECKLIST Project Name: ~~ ~~~ l'z)z..,/Cf.&f Job Address:f=OUf'-'rA(N HI u...-~ b.e, vE I. CLASSIFICATION OF BUILDING: A. Use of Building 1. Occupancy Group (Table 5-1) _rY\ ; S - , / 2. Occupancy Separations (Table 5-B) ~ C. Type of Construction (Table 5-A) ~ :II. - N // Location of Property If:- /' J>). .. I Al i S I ~ vv F~~nt t?O.f.. Rear 75 L. Side .. ~ R. Side 7~( B. D. Floor Area 1. Actual:32 (8S 2. Allowable (Table 5-C) ~ 3. Area Increase a) Open Area (505) fia;Jo .JC../~ e /~ax:;> b) Sprinkler (505.3) I~ /<,:-:;5::= ~ c) Multi-Story(506) ~/<:2..::: y~ 4. Mixed Occupancy Calculation = --I)-- E. Height and Number of Stories 1. Actual: Stories e Height 2. Allowable (Table 5-D): Stories ( Height 40 3. Allowable Increase ~ CITY OF PRIOR LAKE BUILDING INSPECTION DEPARTMENT COMMERCIAL & MULTI-UNIT FIRE PLAN REVIEW CHECKLIST Project Name: l)Jf:A.sSco ~\C-6- Job Address: F o...>~tA. I N M l <....<-- S DUL \1-(~1~1 . Provide access roadway for fire apparatus in accordance with Section 902 of the Uniform Fire Code (UFC). This includes the following: (1 (v) / ( tj' (.f (v{/ All-weather driving surface. 20 feet of unobstructed width. 13 feet 6 inches of vertical clearance. Adequate turning radius capable of supporting fire apparatus. The radius is: 45 feet for a sprinklered building. 60 feet for a non-sprinklered building. Dead end access in excess of 150 feet long shall be provided with a turnaround. ~ Access roadways shall be extended to within 150 feet of all portions of the exterior walls of the first story of any building per UFC Section 902. Where access cannot be provided, an approved fire protection system shall be provided. ~ An adequate and approved access for Fire Department equipment must be provided during construction. If on site pavement is not provided when construction begins an approved roadway surface must be installed with approved dimensions which will support fire vehicles and equipment. . Non-sprinklered Building: Fire hydrants are required per UFC Section 903. All portions of the exterior of any non-sprinklered building must be within 150 feet of an approved fire hydrant. ~prinklered Building: Buildings with a sprinkler system require one hydrant within 150 feet of the fire department connection and a hydrant(s) within 300 feet of all portions of the exterior. The fire department connection shall be located on the front of the building. The PIV must be located a minimum of the height of the building away. FIREPL AN. DOC ~l hydrants shall be accessible to the fire department apparatus by roadways meeting above requirements. Hydrants shall be located within 5 feet of the curb so that apparatus can pull along side for the connection. ([) Provide fire lanes for fire apparatus response. Signage should read: "No Parking Fire Lane by order of the Fire Department." Location and number to be determined. @ Provide numbers of addresses in such a way to be plainly visible from the street or road fronting the property per UFC Section 901. Numbers shall contrast with their background. ~ownhouse projects must have directional signs designating the numbering sequence of units for each individual roadway. (f) Provide approved key box to be installed in accessible location per UFC Section 902. This is required when access to a structure is unduly difficult or where immediate access is necessary for life safety or fire fighting purposes. Key boxes shall contain keys to gain necessary access. Key boxes also recommended for building where entry may be delayed and to prevent damage as result of forcible entry. Obtain order forms from the Building Inspection Department. r;t;) Fire extinguishers are required for this project per UFC Section 1002. Extinguishers are l/ required to be a minimum 2AIOBC rated and located within 75 feet travel distance of all areas. This distance decreases for more hazardous occupancies. Location and size to be determined. (9 Submit plans for required fire protection equipment to the Building Inspection Department per UFC 1001. Requirements based on the 1997 Uniform Fire and Building code. Submit two copies of detailed shop drawings before installation to receive approval and permit. (One copy will be returned.) The contractor should submit installation permit application with plans. (0'; Automatic fire extinguishing systems (sprinklers). (J) Sprinkler systems of more than 20 heads must be monitored by an approved 24-hour station. () Fire hydrant systems. () Wet standpipe systems. () Fire alarm systems. () Cooking appliance and vent extinguishing systems. () Fire pumps. () Other extinguishing systems. & Fire alarm plans must be submitted by State licensed electrician or low voltage contractor. FIREPLAN.DOC . Protection systems installed that are not required are subject to approval by the Fire Department and must meet code requirements. (5) Submit 8-1/2 x 11 inch site plan for development of emergency response plan. ~it plans for underground storage tank installation to the State Fire lVlarshal for approval. Upon approval, submit approved plans to the Building Inspection Department which will conduct the inspection and testing. . Provide information or see instructions as indicated below for special hazards. Please supply information, plans, specifications, as applicable. () Places of assembly, UFC Article 25. () Cellulose nitrate storage in excess of 25 lbs., UFC Article 27. () Storage and handling of combustible fibers, UFC Article 28. () Garages, repair, UFC Article 29. () Dry cleaning operation, UFC Articles 36 and 79. () Application of flammable finishes including dip tanks, spray booths, etc., UFC Article 45. () Welding and cutting operations, UFC Article 49. () Refrigeration equipment using other than air or water and more than 20 lbs., UFC Article 63. () Compresses gases, flammable, UFC Article 74. () Compresses gases, non-flammable, UFC article 74. () Cryogenic fluids, UFC Article 75. () Explosives or blasting agents (storage or use), UFC Article 77. () Flammable and combustible liquids, UFC Article 79. () Hazardous chemicals, storing and handling of hazardous materials including toxic chemicals, poisonous gas, hazardous waste as defined by DOT and EP @ regulations, UFC Article 80. l () . High piled combustible storage, UFC Article 81. -- This includes requirements for fire sprinklers designed for proposed commodity and storage arrangement, building access, access doors, smoke and heat removal, curtain boards, and hose connections. () Liquefied petroleum gases, UFC Article 82. FIREPLAN.DOC Memorandum DATE: December 29, 1999 TO: Jane Kansier FROM: Robert D. Hutchins {llJ~ RE: Wensco, Inc. Office/Showroom Following are the results of the preliminary plan review for the Wensco, Inc. Office/Showroom. Our review was based on the Minnesota State Building Code (MSBC) which adopted with amendments the 1997 Uniform Building Code (UBC) with handicap regulations of the Minnesota Accessibility Code Chapter 1341 and with requirements of the 1998 Minnesota State Fire Code (MSFC) which adopted with amendments the 1997 Uniform Fire Code (UFC). 1. Submit signed architectural, structural, site, and utility plans. 2. Submit mechanical, plumbing, fire alarm, and sprinkler plans. May be submitted at a later date. 3. Submit a soils report. 4. Provide the Illumination Budget Calculation Summary, MN Energy Code Part 7670.080. 5. The proposed warehouses have no occupancy separation provisions to store or drive motorized vehicles into any area. Provide a letter stating that "Motorized vehicles other than electronically driven, will not be driven or stored in the building." 6. Submit Energy Envelope Calculations. 7. A S.A.C. determination must be completed by the Metropolitan Waste Control Commission. Contact Jody Edwards at 651.602.1113. 8. Submit the Structural Engineers requirements for Special Inspections UBC 1701.5. See enclosed. 9. Separate tenant finish permits required for each tenant space. 10. Provide three HDCP onsite parking stalls that shall be located on the shortest possible route to the entrance to the building. MSBC 1341.0403 and 1341.0428 Subpart 2. 11. At least one of the HDCP parking stalls must be a van HDCP parking stall. MSBC 1341.0403 Subpart E subitem 2. 12. Ventilation for the building must meet UBC Chapter 12. Provide 15 CFM of ventilation air per occupant. 13. Provide fire lanes for fire apparatus response. Signage to read :" No Parking Fire Lane by order of Fire Department". Locate by Fire Hydrants and by Siamese connection. UFC 1001.7.1. 14. In-rack sprinklers, early suppression fast response sprinklers or an other approved system that meets the National Fire Protection Association (NFP A) section 231c is required for all storage areas where the top of the pile storage is over 12 feet above the floor or grade. 15. Provide fire extinguishers minimum 2AI0BC rated, within 75 feet travel distance of all areas. UFC 1002. 16. Provide exit signs at exit doors. UBC 1003.2.8.2. 17. Provide a racking and equipment layout. 18. Provide emergency lighting. At the time of rack installation, a final determination will be made as to the visibility of exit pathways. 19. Provide two parking spaces for commuter van. MSBC 1300.4100. 20. Provide a recycling space. MSBC 1300.4700. 21. Automatic garage doors to comply with State of Minnesota Statutes. MSBC 1300.5900 22. Lighting Store: East Exterior door to swing out. UBC 1003.3.3.1.5. 23. Lighting Store: The second floor does not meet definition ofa mezzanine. UBC 507. 24. Lighting Store: Two exits from second floor office. UBC 1004.2.3 .2. 25. Lighting Store: Provide an elevator to second floor office. MSBC 1341.0405 Item E Exception 1 Subitem 4. 26. Appliance Showroom: Male and Female lavatories required. UBC Table A-29-A. 27. Appliance Showroom: Swing West Exterior door out. UBC 1003.3.3.1.5. 28. Flooring Store: Change in floor elevation shall be by ramps. UBC 1003.2.6. 29. Rooftop equipment must be served by stairs. MSBC 1300.4500. 30. Dock Stairs require handrails. UBC 1003.3.3.6. This is a preliminary review only. Other code items will be addressed when the final plans are submitted. The building plans must be reviewed by the Cites Developmental Review Committee (DRC) which consists of representatives of Planning, Engineering, Parks, Finance, and Building Departments. The DRC must approve the plans before a building permits can be issued. 2 CITY OF PRIOR LAKE 16200 EAGLE CREEK AVENUE S.E. PRIOR LAKE, MN 55372 SPECIAL STRUCTURAL TESTING AND INSPECTION SCHEDULE Project Name Location SPECIAL STRUCTURAL TESTING AND INSPECTION Specification Description Type of Inspector (3) Report Frequency Assigned Section Article Firm (4) Notes: This schedule to be filled out and included in the project specification. Information unavailable at that time, to be filled out when applying for a building permit. (1) Use descriptions per UBC Section 1701, as adopted by Minnesota State Building Code. (2) Special Inspector - Technical, Special Inspector - Strucural. (3) Firm contracted to perform services. ACKNOWLEDGMENTS Each appropriate representative shall sign below: Owner: Firm: Date: Contractor: Firm: Date: Architect: Firm: Date: SER: Firm: Date: SI-S: Firm: Date: T A: Firm: Date: SI-T: Firm: Date: TA: Firm: Date: SI-T: Firm: Date: F: Firm: Date: F: Firm: Date: *The individual names of all prospective special inspectors and the work they intend to observe shall be identified. (Use reverse side of form if necessary.) Legend: SER = Structural Engineer of Record SI- T = Special Inspector - Technical SI-S = Special Inspector - Structural TA = Testing Agency F = Fabricator Accepted for the Building Department by Date SSTI. DOC CITY OF PRIOR LAKE DRC PROJECT REVIEW CHECKLIST PROJECT NAME: Wensco, Inc., Office/Showroom - Fountain Hills Addition An application for Site Plan approval of the office/showroom builidng located in Fountain Hills Addition. APPLICANT: Wensco, Inc. 1895 Plaza Drive, #200 Eagan, MN 55122 PROJECT ENGINEERS: Pioneer Engineering Nick Polta 651-681-1914 CONTACT PERSON: Kelly Murray 651-406-4400 SITE INFORMATION PID#: LOCATION: Lot 1, Block 2, Fountain Hills EXISTING ZONING: C-4 COMPREHENSIVE PLAN: c-cc PROJECT REQUEST: Review site plan for necessary changes. DISTRIBUTE TO: APPLICATION FOR: X Frank Boyles Administrative Land Division X Sue McDermott Comprehensive Plan Amend. X Ralph Teschner Jeff Evens Conditional Use Permit X Paul Hokeness Lani Leichty Home Occupation X Bob Hutchins Verlyn Raaen Rezoning X Don Rye X Doug Hartman X Site Plan X Jane Kansier X Fire Chief Preliminary Plat X Jenni Tovar X Bill O'Rourke PUD DNR - Pat Lynch x Minnegasco Final Plat County Hwy. Dept. X Watershed Dist. Variance X MNDOT X Telephone Co. Vacation SMDC X Electric Co. X Mediacom Cable Met. Council Date Received 1219/99 Date Distributed 12/17/99 Date Due 12128/99 Complete Application NA Date Distributed to, 12/17/99 DRC Meeting 1/30/99 Date ORe Publication Date NA Tentative PC Date NA Tentative CC NA Date 60 Day Review Date Review Extension 1:\99files\99sitepl\99-070\referral.doc Page 1 I have reviewed the attached proposed request (Wensco Office/Showroom) for the following: Water City Code Grading Sewer Storm Water Signs Zoning Flood Plain County Road Access Parks Natural Features Legal Issues Assessment Electric Roads/Access Policy ./ Septic System Gas v Building Code Erosion Control Other Recommendation: Approval / Denial Conditional Approval :5~ ~ I z-/zr 1; Comments: Signed: Date: Please return any comments by Tuesday. December 28. 1999, to Jane Kansier, ORC Coordinator City of Prior Lake 16000 Eagle Creek Avenue SE Prior Lake, MN 55372 Phone: (612) 447-9812 Fax: (612) 447-4245 . I :\99files\99sitepl\99-070\referral.doc Page 2 ~. - ~- WOVS. ~N Ort=-Ic:;.6- tz/27~ (~ ). c::::-../"--T~."'-.' · f pr. ~, I /) {^.-/~ -> /vo;- ~<.J.-.' g;,e....?oiftrr. s Wff7~ /;0 eteV: ~ /.;ocP fJ$fLt,tVL, Sn~ -[L/fV6' /N ~ .~ r~ HAJtsIr~Ip-.l. ~ . Cuf-~ 0G/J, W/p vP In (./ .s T ~~ J9s C Go;X:- (0 r/-~ ~--f'CS- )./H /a1;./ /3L6- .1. m""5r & V A/V Access I !3C6:'" ~ ~ f'/Vf2t</~ 5/~5 &1<-11) A E> 0R-1 fJ 6 C, (~P- \ D C-i) 0{2.. to Dc { I 0 It- 3~?>4-~~ ":: 10,,':/04- 72100 7Z.~ 11(p I \ c~L< P wX.;~AUA- 32.. \ 8 S ~f( ~?~c:T ..---~LlbfITl~ ~t:;<:rpcae. ~,..V~ O'-"T, L{&~t2 ~trS ~ e/:Pr~.z.. 4tic.."'~ - II/c:;r A 1Y1~/06 Is.lf 21::.... ~3:(e.L€V~ To onq4.-~ f}.p,o(.,/~ . rn f r 5f/o...u~ 1( L4 VM'~ ,4;.pt:l. ~>'-UiA.V Lv c-><r. OQ.}~ 0(.), ri-aflrAh fC//J' vo(' /.'-' 6;.L"-v m.--?A5 ~ /2h?1"e', f fi/}/UJ M c..s eN j;Jt:::c-f< 5T''ff~ 5 42 / 5'2 zti:,A'7 z~.F Re-~ I~ 1/J'!t.V I we- I t..4-V (z/~14r r:';20~ ..48 ". ~A-N/TA/.IC'N ~ 3343 ....,/t;//..~ 0t70 ~ w~U/ ~L. ~.. I u.; c:.., j U J (,A/h/ //.;(.)~. /L~V~ .~ 72% 0:- 3& /8H'j ~r ~ IU/~ 1t;.At/ I U/c, / wtv Nc> p~~ D .\L~ a /'Y1 4/E- t f4 ~I ~ '"3~ "'" ----~O ::: 72- ~~ F ~ I~~ (LAv. I 0~ Ie-/'? v r'p-~;t'~L) I tA...J C-1b1/./ I ~'-- /t/TI/. fflM>c~-'Z-1-A N~ ~U;I/S 1\I~#a. /fk€C I ( I' M . N E: vJ '1/18/ Ow c."", (... G<.-' '-""\-11 OIN S - ~Ol?OS6-D To ClY'tNC::>€ 7::,1"-'61..-6 -r6fv~; tNTO I L~ TE:;,.J~NT AE t AB 1.~ FL.OO~ s~ O~\c.lr tl 1/ 5 AE ("UAJL6 t.is e- 5'411 L ( 4(0 ~ ..; Zoo ~ lo I 5'S F to B<Qo ...;. J?t>o -= Z i 70 6S;M 64 F " . \ u Lb6 ("1 F \ bUtili5 RE Q 2'1"A '2 W. G J LA\) ~w.L.. lLAV -SZ/3Z-4- PfZ-OP~ 3W..L, ~LAV ~ Uj. G,. -5 '-A v" 109 New f0~ o..tL. - 0 f\-u--\OI'-~ FoJ2- ~ ~ ~c.p. - GC'wI~ u~. ftz../~C{)- 10,...7 p~ To e:t-1IV'I~ ( z~ f!- tAu. ~ ~'fo ((J~ ..o.'t. 10 ~1V\1~ ~ DEVELOPMENT REVIEW COMMI~IATEE MEMO TO: FROM: DATE: RE: DRC Members Jane Kansier, Planning coordinato~~~ August 30, 1999 .~ Concept Plan for Development of Lot in Fountain Hills Attached is a concept plan for the development of a warehouse/showroom facility in the Fountain Hills development. Wensmann Homes has asked us to review this concept for comments and suggestions. Obviously, there is very little information to review at this time. However, please take a moment to look the plan over and identify any glaring deficiencies or changes that must be made. If possible, I would like to discuss this at the next DRC meeting. Thank you for your help. Please let me know if you have any questions. Enclosure :. : ~-v P6Z-7 ~ ~ 5~. SLJ ( L~ STfLf;,/ c T. P <-/ltv;V, /V~ ~ r E;vGlL-G7 fho S~ - PAd-J<I^,,- ~G~ !l~ t::--;p I T)~ Sf::> IY rJ( L . PAGE 1 1:\99files\99subdiv\99final\ftnhills\concept.doc ~-" ULL J ~ \ \ :l ~:;. ,.;lr:~ ~il':" d}l V >-j tJ )1 I d l- LL. <( ~ C ,~ ~~. . ~ ~ I~~ ~ . ~~. \~ ~.: V. ~ 'It "-. ~ ~ '" ll&M ~ ~ ~ ~" ~ ~ .~ ~ ~ ~J~ .~ \'i. rJ\ ~ ~ ~ ~~ gj~ J ...........~.. gln lJ..t.:) 0: ~ rJ) ~~ ~ '- JJ ~ <:) ~ ~~~ ,~~ :.: u o a t.:) z a <( o ..J ~. : 't 'S. n ~~ .: _\ i\ ~~ ~ ~ ~ ~ ~ti J: V1 w '-...... ~ V1 ::J \ ~ \/\ ~ v I~ ;= ~ ~ '- ~ "~ w~ "--- ~ ~ ~ ~~ . -. a ~ . -. .~ ~~ .7"" 't- \j. s:- 'j- t!. ~ ~ . ....... ~ '" ;~ <S '~l . l... ~ 'l ~{i ~~~ ~~ ~~~ ()~() t) l ~~ ~.J.. ~~ ~ ~ r~ ~ lA- ~ J. }J .::: ~ Jl.t-' "U ~.~ '..:! ~ J~'il~! ~, ~ .0-,0'; 2 (Y) i I- U. c( ~ c _."~ N\ ~ , ~ N , ~ w a:: 8 V1 'w U Z <( :J 0- 0- <( May 9, 2000 Wensco, Inc. ATTENTION: KELLY MURRAY 1895 Plaza Drive Suite #200 Eagan, MN 55122 RE: City of Prior Lake Review of the Site Plan Application for Lot 1, Slock 2, Fountain Hills Addition Dear Kelly: The City of Prior Lake Development Review Committee has completed its review of the revised plans for the Showroom/Office Building on the property described as Lot 1, Block 2, Fountain Hills Addition. The following comments and/or changes must be addressed prior to approval of this site plan: 1. Parking/Loading: a) The floor area of each use in the building requires a total of 64 parking spaces; only 63 spaces are shown on the plan. b) The width of the loading area driveway cannot exceed 36' at the right-of-way line. 2. Landscaping: a) A 30" berm is required for screening in front of the parking lot. The berm shown is approximately 24" in height. b) A Bufferyard Type "B" is required along the parking lot. While your landscaping plan identifies the proper number of plantings, these plantings are not arranged to provide screening. The plan must be revised to provide the screening for the parking area. c) Your letter notes the air conditioning units will be located on the side of the building and screened by landscaping. The location and screening must be identified on the landscaping plan. d) An irrigation plan must be submitted. 3. Building Materials: a) To qualify as a Class I material, stucco must be textured cement stucco. This should be noted on the plans. 16200 E!~~r~S'e~i~~~~~~a~~~~Prior Lake. Minnesota 55372-1714 / Ph, (612) 447-4230 / Fax (6121a~1t7-4245 AN EQlJAL OPPORT'<iTY E;\IPLOYER -,~0 3:49PM FROM PIONEER ENGINEERING 681 9488 P. 1 DATE: April 18.. 2000 SENT TO: Bob Hutchins PIONEER ENGINEERING, P.A. Civil Engineers - Land Planners - Land Surveyors - Landscape Architects ~; \. FAX COVER SHEEJ: FAX #: 612-447-4245 CO:MPANY: City of Prior Lake SUBJECT: Fountain Hills LI, B2 FROM: Nicholas Polta NUMBER OF PAGES (including cover sheet): 3 Please call (651) 681-1914 if you did not receive clear copies or if any pages in the sequence are missing. Bobt I have attached a sketch of the new proposed PIV, Siamesse connection and turn around locations. Please let me know if they meet your requirements. If you have any questions or require any additionai information please feel free to call. SincerelY1 ~J-r /2~ Nicholas Polta 'TfTYcd) 70 f jefr 70 3~ jWqL 1; ~ en- &-lml~~~i6N. 2422 Enterprise Drive - Menclota Heipts, Minnesota 55120 - (651) 681-1914 - Fax (651) 681-1914 625 Highway 10 N.E. ... Blaine) Minnesota 5S434 .. (612) 783..1880.. Fax (612) 783..1883 -,-"'00 3:50PM FROM PIONEER ENGINEERING 681 9488 P.2 \ 1" C) I ~rv ~. I 'l <c \- \ \ \ \ , , ~ \ \ !I,'? \ , J' \ ~ ~\ fs 'C' \ (,,~ \ \ III . ~\ \ " 0 \ \ \ \j\ \ \ \ ~ ~ \ \ \ ' \ \ Z\ \ 4.\ \ \ '\-" ~ z' \ 8 ::>\ \ \ ~\ 0 \ \ \ u..., \ \ W\ - .- ---- ---- .-- \ \ ~ \ -- -- -- -- - \ \ \ to-' - \ ::>\ \ ' \ U-\ \ \ \ \ \ \ ' \ \ \ , \ ~ \\ \ \ \ ,........ -, \; " "'- '0\:>, ::--:..'~~ " "", I. / o !I,' * 4.' ~. ~-~ Q !\,' 4' (,,"$' 4,. Q CITY OF PRIOR LAKE ORe PROJECT REVIEW CHECKLIST PROJECT NAME: Wensco, Inc., Office/Showroom - Fountain Hills Addition - REVISED PLANS An application for Site Plan approval of the office/showroom building located at 4385 Fountain Hills Drive NE, and described as Lot 1, Block 2, Fountain Hills Addition. APPLICANT: Wensco, Inc. 1895 Plaza Drive, #200 Eagan, MN 55122 PROJECT ENGINEERS: Pioneer Engineering Nick Polta 651-681-1914 CONTACT PERSON: Kelly Murray 651-406-4400 SITE INFORMATION PID #: 25-363-003-0 LOCATION: This property is located at the southwest quadrant of the intersection of Fountain Hills Drive and Fountain Hills Court, on the west side of Pike Lake Trail EXISTING ZONING: C-4 COMPREHENSIVE PLAN: C-CC PROJECT REQUEST: Review site plan for necessary changes. DISTRIBUTE TO: APPLICATION FOR: X Frank Boyles X Bud Osmundson Administrative Land Division X Sue Walsh X Sue McDermott Comprehensive Plan Amend. X Ralph Teschner Jeff Evens Conditional Use Permit X Paul Hokeness Lani Leichty Home Occupation X Bob Hutchins Rezoning X Don Rye X Doug Hartman X Site Plan X Jane Kansier X Fire Chief Preliminary Plat X Jenni Tovar X Bill O'Rourke PUO DNR - Pat Lynch Minnegasco Final Plat County Hwy. Dept. Watershed Dist. Variance MNDOT Telephone Co. Vacation SMOC Electric Co. Mediacom Cable Met. Council Date Received 04/13/00 Date Distributed 04/13/00 Date Due 04/27/00 Complete Application 04/13/00 Date Distributed to 04/13/00 DRC Meeting 04/27/00 Date DRC Publication Date NA Tentative PC Date NA Tentative CC NA Date 60 Day Review Date 6/13/00 Review Extension 8/13/00 I :\99files\99sitepl\99-070\refrevis.doc Page 1 I have reviewed the attached proposed request (Wensco Office/Showroom) for the following: Water City Code Grading Sewer Storm Water Signs Zoning Flood Plain County Road Access Parks Natural Features Legal Issues Assessment Electric Roads! Access Policy Septic System Gas ./' Building Code Erosion Control Other Recommendation: Approval V Denial Conditional Approval Comments: Signed: Please return any comments by Thursday. April 27. 2000, to Jane Kansier, DRC Coordinator City of Prior Lake 16200 Eagle Creek Avenue SE Prior Lake, MN 55372 Phone: (612) 447-9812 Fax: (612) 447-4245 I :\99files\99sitepI\99-070\refrevis .doc Page 2 1895 Plaza Drive Suite 220 Eagan, MN 55122 651.406-4400 651.905-3678 Fax Commercial Development · Construction ~ April 12, 2000 To: City of Prior Lake Planning Staff 16200 Eagle Creek Avenue S.E. Prior Lake, MN 55372-1714 From: Kelly Murray WENSCO ~~? I~ ;".." i I r r.:=l II~/S 0 L5 U Wl5l,n ~~I APR I 3 200J j U RE: Site Plan Review, Lot 1, Block 2 Fountain Hills Addition Enclosed is a complete set of revised plans for the proposed Showroom/ Warehouse Building located in Fountain Hills Business Park. We have received comments from staff and feel that all items have been addressed on the revised plans. Flooring Center The proposed building is designed to provide offices and showroom facilities for a flooring center which provides selections of wood, ceramic, carpeting, vinyl, and a variety of selections for builder clients. The showroom does not have a retail client base, it is a builder base customer. Hours of operation are Monday through Friday 8:00 a.m. - 5:00 p.m., Saturdays and evenings by appointment only. The warehouse will be used to store flooring materials that are scheduled to be installed, with some inventory. Shipments are received daily and must be off-loaded by fork-lift. No more that four deliveries will be made in one day. Currently, the company has five full-time employees, and is planning to expand to eight shortly after the move. Lighting Center The proposed building is designed to provide offices and showroom facilities for a lighting design center for both builder based and retail based customers. Hours of operation are proposed to be 8:00 a.m. - 8:00 p.m. Month - Thursday, Friday and Saturday 9:00 - 5:00 p.m. This will be a start-up company that will have at least 8 employees initially. The warehouse will be used to store stock light fixtures, bulbs and accessory items related to the operation. It will also be used to temporarily store selected fixtures that have been ordered until installation can be scheduled. Additional Showroom Space This bay was designed for another showroom/ warehouse type use. We are currently working with a client that is interested in an appliance showroom however, terms have not been agreed upon. This would again be primarily builder based, with some retail customers. Hours of operation would be more consistent with the flooring centers hours. Distribution of the appliances would not be out of this facility. It would only be an overstock area. The client also has some specialty plumbing related fixtures and custom home wiring. Design Features The building meets or exceeds all material requirements on four sides. All access to warehouse for delivery is off the cul-de-sac, eliminating additional traffic on Fountain Hills Drive for the future. All mechanical systems will be located within the structure, eliminating roof heating systems that would require screening. All trash will be enclosed within the warehouse. Each unit will have separate water services, with one service on the east bay for irrigation of the grounds. Air Conditioning units will be located along the side of the building, with landscaping provided to screen the view. Precise location has not been determined yet. Upon building permit application, a complete set of signed architectural plans and signed civil plans will eb submitted. If there are any items you feel we have not addressed from the previous comments, please feel free to contact me at our administrative offices 651-406-4400. Sincerely, \ iAJ pill- Lfl1u.)Jt ~ ~J~~y Development Assistant '\ oW"'-- S,qvOS t-b~ M(.,;J~*"" (5 p~ '-'\. 12/1 /~ VAI-UIE.: ~PeIP;< 3j..13::: tJcqa:;x:;.- VA-t.v~ ~A--C- U#lrS I'1t 3~50:: 3 2., 1$S"s-,4e>ao :: 42, 350. OQ II ~G- VNIT5 /E.Snm~ ONL7 ~~~b 3 233.15 , lOcO 1- ~~~ ~~~- .. - tO~ · ~~".l) ~ ",.. <.) \4-25.00 4, {p SB.'1S ~O-ZS~ I, 400..t!TO -+~:r; I ~~ 0 -- 6 c:;>( 13>~ . ~ ~ ~ &&0. - J',~ " ,,~. 1-s' ~~f3~.I( 5 0 0 . c9D ---......-..... )l \ b4\l\?J e::s r (~Pr"nG C>~ '-1 5\liq\. -.'------... \~ \.. J . "" _..,,~ ' ...'.,.... .... ""--- DATE: L ~ 'Il1lW To: YEZ2- @# @# @# FROM: ~ .... NUMBER OF PAGES: -... (including cover) FAX No.: 447-4245 Notes From The Sender: PLEASE CALL ALL PAGES. IF You Do NOT RECEIVE AT 16200 Eagle Creek Ave. S.E., Prior Lake, Minnesota 55372-1714 / Ph. (612) 447-4230 / Fax (612) 447-4245 AN EQUAL OPPORTUNITY EMPLOYER BUILDERS MORTGAGE COMPANY LLC ',-,'~._....- --''- -~""""""''''''''''''--- ._~~. ;,;\j r~_~ r)J I~'~j ffB ~-;;JWI 646 East River Rd, Anoka, MN 55303 (763 )-323-0820 (763)-323-9105 (Fax) Construction Loan Specialists for Professional Builders 14300 Nicollet Court, #110 Burnsville, MN 55306 (952) 898-1110 (952) 892-6555 (Fax) February 1, 2001 o~ 00/ City of Prior Lake 4628 Dakota Street SE Prior Lake, rvn~ 55372 Re: Lot 1, Block 2, Fountain Hills Addition - Wensco, Inc. Re: AMENDMENT Our Irrevocable Letter of Credit No. 5656-600-LS Dated: June 13, 2000 Ladies and Gentlemen: Builders Mortgage Company LLC hereby amends Irrevocable Letter of Credit No. 5656-600-LS Dated: June 13, 2000, as follows: 1. The Expiration date of the above referenced Irrevocable Letter of Credit is hereby extended to February 1, 2002. All other terms and conditions remain without change. Very truly yours, BUILDERS MORTGAGE COMPANY LLC P;d:i~~- Patricia Filip Chief Financial Officer elT. ; PRIOR LAKE INSPECTION NOTICE SCHEDULED TIME ADDRESS ~B5 ~~oI/V OWNER CONTR. PHONE NO. PERMIT NO. o FOOTING 0 PLUMBING RI 0 EX/GRAD/FILLING o FOUNDATION 0 MECH RI 0 COMPLAINT o FRAMING 0 WATER HOOKUP 0 FIREPLACE RI o INSULATION 0 SEWER HOOKUP 0 FIREPLACE FINAL (LFINAL 0 PLUMBING FINAL 0 GASLlNE AIR TST o SITE INSPECTION 0 MECH FINAL 0 COMMENTS: 0-J~. <: ~ wr (k -;;-l ~ tSJ f=-tz- ?~ t:-(AAItt- \ ~~~ C~O. t~s~ . /1150 rt Ie- #15 OCJ -8~~ DO' >?s-I ()() - ~S- d- ~ORK SATISFACTORY, PROCEED o CORRECT ACTI D PROCEED o CORRECT W REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYI _/ INSNon ADDRESS Lt b~tS- DATE TIME SCHEDULED r2ltle I ~}./ b41.LL-t; CIl F PRIOR LAKE INSPECTION NOTICE OWNER CONTR. PHONE NO. PERMIT NO. (?b",L!fl,C( o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST Ji COMMENTS: J1kJ '~r~ 4 Jt/ tll'L~~U6!~ OYV~ Q - l~(J/~/~6 / ~ORK SATISFACTORY, PROCEED o CORRECT ACTION AND PROCEED o CORRECT WORK, CALL FOR REINSPECTION BEFORE COVERING Inspector: ~ t.6. Own er/Contr: CAll 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTI DATE TIME CIl ,= PRIOR LAKE INSPt:CTION NOTICE p/~( ~ ADDRESS tf3Ss E~~ LJtU~ ~ OWNER ~~ CONTR. SCflEDULED {):?,- 'itpq PHONE NO. PERMIT NO. o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL ~SLI ,AIR TST &> ZI ~ . 3. ~z:b tf~bcj ~~ ~&t ve:D(.[~1 o WORK SATISFACTORY, PROCEED ~ ~~ f ~ ;9RRECT ACTION AND PROCEED YCORRECT WORK, CALL FOR REINSPECTION BEFORE COVERING Inspector: ~ OWner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYl J 395 - ~ & msNOTJ-tr eND ~Ci-qCi/)'L/ a 5/ d- ,)-- r--e TIME CITY OF PR. ;;LAKE INSPECTION NOTICE SCHEDULED 5/ t.J / [)J I . ADDRESS t.f 3 ~ 5 Fou N T\ ~~ t-\ 'L-'- ~ Dc<. OWNER "TOM. CONTR. k \frJSc..o PHONE NO. PERMIT NO. O() - Y f.p 9 o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL ~ EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GAS LINE AIR TST o COMMENTS: CRAD.N(. OK , OK,-o LA ,,-\0 .sC APe. ~ ~D MAINI41^J E"R.Q<..,,,......\ Ct\~OL- ON,-',- SoD IS CST11aLl$"'~ CAu.. eJJ(~. ~.Pr. ..,,, SET' uP .5tl~ITI\-R'1' I uJATFZe I I C ~ G I ~ TC. . , tJ.$f~ &, "-1Df'.1 )( WORK SATISFACTORY, PROCEED o CORRECT ACTION AND PROCEED o CORRECT WORK, CALL FOR REINSPECTION BEFORE COVERING Inspector: Vt ~ 9"n~~r: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTI 11-?l'O Po Ufi./ +?l i )L) CITY OF PRh, -AKE INSPECTION NOTICE SCHEDULED ADDRESS 1f 3 'J~ OWNER CONTR. PHONE NO. PERMIT NO. o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL COMMENTS: o'~ 0" -~ TIME Ide) 00- Hi' j ~C; 4fti4 ~ o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL Y1 J) ~ASLlNE AIR TST / V L o ~4/~ ;{ ~ BCZl;$ ~ ~ I / ~ORK SATI CALL FOR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTI CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! 4-335 FoVN~l rJ ~(~S> O~. I~) () - 7~ CITY OF PRIO..... ..AKE INSPECTION NOTICE ~l?~ SCHEDULED ADDRESS OWNER CONTR. PHONE NO. PERMIT NO. /A\))('PLUMBING RI ~~~ECHANICAL o WATER HOOKUP o SEWER HOOKUP o SEPTIC INSTALL o PLUMBING FINAL o SITE INSPECTION o FOOTING o FRAMING o INSULATION o FINAL o FOUNDATION o DEMOLITION o FIRE PREVo COMMENTS: OJ TIME l~" -0 0 L \ '3-e) o EXC/GRAD/FILLlNG o LKSHORE~ETLAND o COMPLAINT o SEPTIC FINAL o FIREPLACE o ~ /+' -- ( ~, ~WORK SATISFACTORY, PROCEED f 0 "'CORRECT ACTION AND PROCEED o CORRECT WORK, CALL EINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-4230 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYl 0" TE TIME CITY OF PRI lAKE INSPECTION NOTICE SCHEDULED Z!ltro I z~oo PHONE NO. 4385 FOUN~IN rt(~ ~ CONTR. UN l-r IA(;c?~(. 00 - ~ r PERMIT NO. on - PJ51 ADDRESS OWNER o FOOTING o FOUNDATION o FRAMING o INSULATION ~ FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER H~OOKUP . &. PLUMBING FI !t MECH FIN o EX/GRAD/FilLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o . . f......l / f'(L( /0 L~ F{.M1C.- z9~. < f22 ~~Ir ffE!}j @~ Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTI [V TE TIME CITY OF PRI ..AKE INSPECTION NOTICE SCHEDULED J . b- 0 I 4385 FOUtJ11t(N M1~5 ADDRESS OWNER CONTR. PERMIT NO. 0 - des I PHONE NO. o FOOTING ~OUNDAT~ FRAMING o INSULA Tio o FINAL o SITE INSPECTION ~~LUMBIr!1 ~ECH RI o WATER KUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLINE AIR TST o COMMENTS: , SVrre; (0' ~ 201 6clr ~ ~ Ft--- o WORK SATISFA TORY, PROCEED ~ORRECT ACTI AND PROCEED o CORRECT 0 , REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl to 8.0 I 4-385 FoUNTAIN rtIU$ CITY OF PRIOR LAKE INSPECTION NOTICE ADDRESS OWNER SCHEDULED CONTR. PHONE NO. PERMIT NO. () - 8S; , S:UfTf5 ll~. ~ 1&v~vV :. .---J~ , 7D (k; t6 (N / ~MENTS: . . 'tt J1t...Jh/7 o(l. o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL DA rE TIME , 1 3..D o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o Inspector: LL FOR REINSPECTION BEFORE COVERING Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl CITY OF PRI ..AKE INSPECTION NOTICE SCHEDULED 0# -r::r TIME lz..~ 2-:~ \~~ t~l~ .~!'\(~ ADDRESS OWNER CONTR. 00- 5LS t+V~ PERMIT NO. ~- C'\ ~, - fL. PHONE NO. o PLUMBING RI o MECH RI o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLINE AIR TST .~ -0.~I~~~loN S~ eN tJNtr ~~~ ~-~~UtJl~ ~-.I~~ ~~~I~S~~~ 5., ~~ ~rs o WORK SATISFACTORY, PROCEED Ji( CORRECT ACTIO NO PROCEED o CORRECT we ,C LL FOR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYl INSNOTI ADDRESS _t6~6 OWNER SCHEDULED l~ ~10 ~L<$ b~ TIME CITY OF PRI, -AKE INSPECTION NOTICE L..;~ CONTR. PHONE NO. PERMIT NO. (X) -~ .,<5.. 5 I~~""CUU~ ~~ \ )..>Cr5 ~ '"{. c..-~~ 'S\P~~5 ~~,vc.. \o.~~:~~:~ Fi~ pu~ \~5 o FOOTING 0 PLUMBING RI 0 EX/GRAD/FILLING o FOUNDATION 0 MECH RI 0 COMPLAINT o FRAMING f)O \ C4I'I 0 WATER HOOKUP 0 FIREPLACE RI o INSULATION ,^-/}~'D SEWER HOOKUP 0 FIREPLACE FINAL ~INAL 0"'& ~~. #I 0 PLUMBING FINAL 0 GASLlNE AIR TST o SITE INSPECTION~Tt>~ 0 MECH FINAL 0 COMMENTS: t.. .PLANt-J,~ ~_ ~ ~VAt--- ~Z. l~ fl~~Sl~S' 3>. J..tA,~ ix-~ C:1 AD/) L IN o WORK SATISFACTORY, PROCEED "jtLCORRECT ACTION AND PROCEED o CORRECT W R CALL FOR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTI CITY OF PRk _ LAKE INSPECTION NOTICE r r TIME / ! SCHEDULED [ ~ · w / t.P 7:- Q:.? /i 1-1.. ~ f~UN frt(N thLLS D;2/ vc: ADDRESS Ll 38~ OWNER CONTR. PHONE NO. PERMIT NO. 00 - 4b'1 o FOOTING o FOUNDATION o FRAMING o INSULAe FINAL eu" ~ ~ SITE INS N o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: vtJ A-A--rs '(U Nce::o Gsr f1pvc (N ~ff1 6v6. /Jcf;Pr , ot- 7V MOve IN. TC#1 P c,o. C:;;NLl( /iLL FiNAL /'/l3P7,5, 7ZJ ~e cI.J-GeJ?6C::> 11'1 >j?~/N~ zool. ~ORK SATISFACTORY, PROCEED o CORRECT ACTION AND PROCEED o CORRECT WORK, CALL FOR REINSPECTION BEFORE COVERING Inspector: 4/~ner/Contr. CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYI INSNOTl ""TE TIME CITY OF PR LAKE INSPECTION NOTICE SCHEDULED J 2.t u:...-; q i 3 U ADDRESS L I I), "< 2.. \t:~ fJt l~~ OWNER W~~'\ CONTR. PHONE NO. PERMIT NO. &0.- Lf 6q o FOOTING 0 PLUMBING RI o FOUNDATION 0 MECH RI o FRAMING 0 WATER HOOKUP o INSULATION 0 SEWER HOOKUP & FINAL 0 PLUMBING FINAL I1i SITE INSPECTION l\ 0 MECH F~L COMMENTS: ~L..IA.~ ~ ~~ o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o I, IS ~ f?"'b"Vl t.P'V: ~~ ~e.c""t.1~ ~~~~ ~~\.Mt1 ~~ ~, ~ LA-5'/V~ -- ~V~4 ~/'-"9'Y1AfJ1 ~~ q, ~'Xe ~4'~ r.~~ 6~ o WORK SATISFACTORY, PROCEED o CORRECT ACTION AND PROCEED ltzl CORRECT WORK, CALL FOR R. EINSPECT. r!.o~ B;FORE COVERING I' /~ llt/? .q'jjS"1 Inspector: . ~ ~~lA .. Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl ~y\ ?s () ,......e TIME CITY OF PR LAKE INSPECTION NOTICE ADDRESS ~3%'5 SCHEDULED l~o/()7J 'j,'tJrJ ~~r-At~ 1I~.s J)/L-I CONTR. c:?::J- ~ OWNER PERMIT NO. ~:-~G o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o PHONE NO. o FOOTING 0 PLUMBING R' o FOUNDATION 0 MECH RI iCFRAMING 0 WATER HOOKUP I ci INSULATION 0 SEWER HOOKUP o FINAL 0 PLUMBING FINAL o SITE INSPECTION tll/O MECH FINAL COMMENTS: ~/.!t~Gc- a2'20 o,K, ,/~ ~ a:>~ c).. k ~ORK SA TISFACTOR ,PROCEED o CORRECT ACTIO AN PROCEED o CORRECT WO AL FORREINSPECTION BEFORE COVERING L, Inspector: Owner/Contr: OR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYI INSNOTl , CITY OF l JR LAKE INSPECTION'NOTICE SCHEDULED / l')ATE TIME /b/faICJo , /a:ChJ ADDRESS L/3rs fi fAA\J'YAttJ fil LLS ,,-- .- r / /t<-{4b ';;f"l- :L ~. q/V~: If/' II/~,--,.-! ~ O~ Ft/f~,. \ ' . /- ~-:Z:/W Z~Z:' 3 ~.<I ~6vSC~>- e' ,p(~ (50 ~ ~~ ~ /\AJI)~ OWNER CONTR. ~HONE NO. Ff ~FOOTINGJ1D o FOUNDA =(,6i( o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. o PLUMBING RI o MECH RI o WAfER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL COMMENTS: 70,~ ~ D-1"'( o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o 'e o WORK SATISFACTORY, PROCEED ~ORRECT AC I AND PROCEED o CORRECT CALL FOR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTI CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYI t "'~ TE TIME CITY OF P. ~R LAKE INSPECTION NOTICE SCHEDULED 1(,;- fp'O 0 31'~ 4385 FDUtJ~/,J f/tU-.>S ADDRESS OWNER CONTR. (J.57S PHONE NO. PERMIT NO. o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o PLUMBING RI )i( MECH RI /j] WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL COMMENTS: pvc.- o EX/GRAD/FilLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o U. 6j. @ !-I~-s J)~A-{/LI TrcG & GLoJ 1,t{w0RK SATISFACTORY, PROCEED o CORRECT ACTION PROCEED o CORRECT WO OR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! I/VS/VOTI \ ' --.."',- ~1>0__"'_'_.~-~'''' _...,.-:",~. ...,-....- .. - .....-. -" ........,......-c.-- --'"'""f'-"'''''''~C:'_--.+~~ .- '~"''''"f~.~ n CITY OF ~-iR LAKE INSPECTION NOTICE SCHEDULED ~TE ~i.()O - TIME ?''? ..,). ---(..) ADDRESS 43t>5 FO(J/'JI7-I/tJ f1(L,W OWNER CONTR. PERMIT NO. (J. s7B PHONE NO. o FOOTING o FOUNDATION o FRAMING o IN$ULA TION o FINAL o SITE INSPECTION o PLUMBING RI ~ MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL COMMENTS: pV'C o EXIGRAD/FILLlNG o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o U.~. @ LJ /-/./-7 <::, j)lfi ' (/\.., !/.-.~. E '-~ G LC) c.. ./ ~WORK SATISFACTORY, PROCEED o CORRECT ACTIO~ tf. PROCEED o CORRECT ~ f1 FOR REINSPECTION BEFORE COVERING Inspector: fL.", 1 Owner/Contr: , CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl . c TIME CITY OF PR.. , LAKE INSPECTION NOTICE Ii - .:J--O (;) , ' iTb ,tL 3 f'5" - ro V- D-ta ; A-) /-J-; }k: Ii SCHEDULED ADDRESS OWNER CONTR. PHONE NO. PERMIT NO. O-LjbC( o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL ~ASLlNE AIR TST COMMENTS: ;2 E:rtsr TC7V~ 6~ L/~5 O.IL kORK SATISFACTORY, PROCEED o CORRECT ACTI NO PROCEED OR REINSPECTION BEFORE COVERING Owner/Contr: Inspector: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl ADDRESS Lf36s .'_ ~-..' F{'~ /tv 1-1 fa cr ~ u- DAT~ TIME SCHEDULED ?(~ho' 9~ V;tA."'t~;,J *t LL-S CITY OF PRIOR' ~ INSPECTION NO. ."E OWNER CONTR. PERMIT NO. e) ~& )( PLUMBING RI~ o MECHRI ~ o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL -oO-~?~ PHONE NO. o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o EX/GRAD/FilliNG o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASllNE AIR TST o COMMENTS: LA, <:r . T fliE V;Vi:)(5R-G~ L) A/~ ?~S ~ 4LL- + ~cA7(cYV5 liAS CfbarN&6Q. ~/A/&. e>r U. b ~€c-<J ~~. ~RK SATISFACTORY PROCEED PROCEED l FOR REINSPECTION BEFORE COVERING Owner/Contr: Inspector: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl CITY OF PRIOR. ~E INSPECTION N011CE SCHEDULED DATI; TIME e/ I '7> t6C5~:" ~ ~TR.~~(f ~\ PERMIT~ O:J;~ ~ ~LUMBING RI 0 EX/GRAD/FILLING o MECH RI 0 COMPLAINT o WATER HOOKUP 0 FIREPLACE RI o SEWER HOOKUP 0 FIREPLACE FINAL o PLUMBING FINAL 0 GASLlNE AIR TST o MECH FINAL 0 ADDRESS 43 e G OWNER PHONE NO. o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION COMMENTS: ft (Jrovt &v~ ~ ~ - f~/c1 ~~ ~sLr~~~ SV~~ (3) 'f ( JV rOl }/\ tJ r - +- ~~ <fr'\ s\r,J V'C\ df. u:: h ~ .5 u..\-; M. " {- p \ '""" c:.. ~ c " ~ \ttfA 0 1 \ !iJ[~ ~ Inspector: Owner/Contr: OR THE NEXT INSPECTION 24 HOURS IN ADVANCE. ENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl DAT~ CITY OF PRior .KE ~ I,"", v }, ., INSPECTION NOTICE SCHEDULED ~ ADDRESS ~ ~ 1SS 17 ~ )'(\ \r:u V\ llillL) OWNER CONTR. PHONE NO. PERMIT NO. NAvPLUMBING RI '/'[} ~ECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION ~t~ - If -~~t' JOlljrU- r~'i %vtv"' ~ I "..., '~ } '~. .,,-il""" vvr TIME ~~(. ~ () .~ q 00 -- ~7~ o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o cAr ~"^ tv if-.- ~fs= ERING CITY OF PR., LAKE INSPECTION NOTICE SCHEDULED 1o~S ADDRESS m T1\\r-D (\ lli~ls ,. -~ TIME ~ I :,~ OWNER CONTR. PHONE NO. vMOOTING A o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL COMMENTS: ~~ r Fl~ CJD-n'lt:.9 o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o eM. CcM--~ fi,o+:-~ EINSPECTION BEFORE COVERING Inspector: Owner/Contr: HE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTI 'S ARE FOR YOUR PERSONAL HEALTH & SAFETY! CITY OF PR~ LAKE INSPECTION NOTICE SCHEDULED ADDRESS i 4 '0)(S fi n /'(\'-\-r1 j t"'\ OWNER CONTR. PHONE NO. V'FOOTING /[1 FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL ~~ jJ44J ; COMMENTS: D"TE TIME "7 )16{JO ~'S 1!30 00 - D4Cct o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o / ~ORK SATISFACTORY, o CORRECT ACTIO o CORRECT WOR Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTl CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! r....e fe CITY OF PR LAKE , I J INSPECTION NOTICE SCHEDULED 71 a '1,00 J: ~ ADDRESS 4-'3 ~5 FC\\. )('\t-o.'~f) t\i\ \ OWNER CONTR. PERMIT NO. 00- 4o~ PHONE NO. -v' FOOTING pC\.) ~t) ,/[j' FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: I. fig,,&. 12 ~ (\i~ l A'f{>raJeJ ~ ~,~€,u- at tt'cpnL 0~ - Foof;~ -:tr N I "2.. L-l;'::j 1\-r-1,z \ /1<>. \A c~ l?i.l::. ~ 'B..to J.. ~)J.\.. , ,# I ,. r~ #- 5 WUt. \~.O.G~ # ~ Hor'Z.- 12 o. c. .j- ~ ~u(" ~~ 'jour ow'^- \i<!;lc. o WORK SATISFACTORY, PROCEED ~ CORRE CTI AND PROCEED o COR CT WO, OR REI SPECTION BEFR~ERING Inspect r: Owner/Contr: ~ NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTl CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! CITY OF prA LAKE INSPECTIO~OTICE . 1/3i 1cfb , , I:J~ TIME SCHEDULED ADDRESS J 4:::) 8 5 """FO--u", --\:tt i (\ ~, \ \ OWNER CONTR. PHONE NO. VFOOTING ,It ftFouNDAnO o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. 00 - OLfCoq o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o Owner/Contr: FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. 'MENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYI INSNOTl CITY OF PRh.. _ . LAKE INSPECTION NOTICE SCHEDULED r' TIME ~ I ;,30 ADDRESS J1S?\5 +7)) ~ i (\ t1l \ 1 OWNER CONTR. PHONE NO. I\r.r{OOTING (9 ~OUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. on - CJtJ69 COMMENTS: o PLUMBING RI 0 EX/GRAD/FILLING o MECH RI 0 COMPLAINT o WATER HOOKUP 0 FIREPLACE RI o SEWER HOOKUP 0 FIREPLACE FINAL o PLUMBING FINAL 0 GASLlNE AIR TST o MECH FINAL ~ t:L FOQtrNb5 ,S<- ~ Inspector: FOR REINSPECTION BEFORE COVERING ~ORKSATISF o CORRECT A I o CORRECT Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNo:Tl 1"""'11: TIME CITY OF PRl LAKE INSPECTION NOTICE SCHEDULED '7 jOlll1JJ . 1.~50 ADDRESS .LJ3~S 'FOUN.TMN Hf/-'- OWNER CONTR. PHONE NO. VFOOTING A- Yo'~OUNDA TION . o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. an - CL/(, 9 o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: ~ ~ rw.- \'-'w' CcUJ J;j Inspector: Owner/Contr: THE NEXT INSPECTION 24 HOURS IN ADVANCE. TS ARE FOR YOUR PERSONAL HEALTH & SAFETYI INSNOTl CITY OF PRl LAKE INSPECTION NOTICE SCHEDULED ADDRESS 4.3 8" 0' Fcflrf""\ 7-o...{11 OWNER CONTR. PHONE NO. ~OOTING P. PO )OUNDA TION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL COMMENTS: ~, a.~ ~J ~ f>ClI..A.I d c...- ....u w ~ ~ .... 4 ~ c.j- 12.." Q.c tI~ ~~ ~ ~~lt ff: := . ~<:.\,~ ~ r!. ~ rO'9'e TIME ~ [-J-j .1 / /.'30 (JlJ -Q '-f~ o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o r1c- <; (~ Inspector: Owner/Contr: INSNOTl W~ J~ ,... .-: CITY OF PRL LAKE ry I J (.,j fry; INSPECTION NOTICE SCHEDULED ~ ADDRESS 43~S fuJI1-dnln /+"/1 TIME 1~3[) OWNER CONTR. PHONE NO. '\a"'FOOTING ~ va.. FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. UD -l)~6Q o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: ION AND PROCEED K, CALL FOR REINSPECTION BEFORE COVERING Owner/Contr: FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. 'MENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYl INSNOTl ,.. . ...,= TIME CITY OF PR\ LAKE INSPECTION NOTICE SCHEDULED 7./t:rOO 1:3R) 4385 ~OUN771/N IfI~G ADDRESS OWNER CONTR. PHONE NO. ~ FOOTING -A /D FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. · %9 o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: J~6~ r~ 1l~Y\ FACTORY, PROCEED TION AND PROCEED o CALL FOR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: OR THE NEXT INSPECTION 24 HOURS IN ADVANCE. ENTS ARE FOR YOUR PERSONAL HEALTH & SAFETYI INSNOTl ,. - Je TIME CITY OF PR LAKE ~ l:3o INSPECTION NOTICE SCHEDULED ADDRESS ~385 fb~~ L{.t,i OWNER CONTR. PHONE NO. PERMIT NO. () - AcbGJ ~OTING A o PLUMBING RI o EX/GRAD/FILLING o FOUNDATION o MECH RI o COMPLAINT o FRAMING o WATER HOOKUP o FIREPLACE RI o INSULATION o SEWER HOOKUP o FIREPLACE FINAL o FINAL o PLUMBING FINAL o GASLlNE AIR TST o SITE INSPECTION o MECH FINAL 0 Oy\. Inspector: Owner/Contr: E NEXT INSPECTION 24 HOURS IN ADVANCE. RE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTl ,.. '~ TIME CITY OF PR~ LAKE INSPECTION NOTICE 1. f't. 00 (:30 SCHEDULED ADDRESS 4365 ~ OWNER CONTR. PHONE NO. ~ FOOTING /d ( 0 'FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. o t/{p q o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMfNTS: -.:Ebn (""'0 r (f1'1\- Inspector: Owner/Contr: HE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTl ,. ~~ TIME CITY OF PR~ LAKE INSPECll0N NOllCE SCHEDULED ~ I : ~ () ADDRESS l/D2S S' fen N' h~l f\ tbl\ \\ r) ve _ OWNER CONTR. PHONE NO. \ ~OOTING ~OV ~ \ ~OUNDATION t>- O FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. em -()4.bQ o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: ~-h"al ~~~ ~~~5~ Y,PROCEED AND ROCEED FOR REINSPECTION BEFORE COVERING Owner/Contr: OR THE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTl SCHEDULED ,.~ ,Jill {46 Q,y, K- TIME CITY OF PR LAKE INSPECTION NOTICE I tOo. "".If) 4385 ...... ~a,n ~., lA CONTR. PHONE NO. PERMIT NO. OOTIW ?a..l-f2~ PLUMBINGRI o FOUND. N 0 MECH RI o FRAMING 0 WATER HOOKUP o INSULATION 0 SEWER HOOKUP o FINAL 0 PLUMBING FINAL o SITE INSPECTION 0 MECH FINAL t; - ~'=A o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: ~ pad fi' c' J It \0 if 6 1><1 xlI, W4:~ ( '-ellv' ... o----:-:h ~i\h ~ ~S r'/'-- Sc;~ Owner/Contr: R THE NEXT INSPECTION 24 HOURS IN ADVANCE. 'NTS ARE FOR YOUR PERSONAL HEALTH & SAFETYl INSNOTl CITY OF PRo LAKE INSPECTION NOTICE SCHEDULED ~ /.'/S- ADDRESS 4365 FOUNTrJltV 1-//[,,-,, ... - --: TIME OWNER CONTR. PHONE NO. )t( FOOTING rJ A o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. ~PLUMBING RI tJ P. o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL -tltP9 o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: Inspector: Owner/Contr: HE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTl CITY OF PR LAKE INSPECTION NOTICE SCHEDULED ADDRESS 4355 ~~ OWNER CONTR. PHONE NO. ~OOTING r~y\i~ \ o FOUNDATION A o FRAMING o INSULATION o FINAL o SITE INSPECTION PERMIT NO. o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP o PLUMBING FINAL o MECH FINAL COMMENTS: 50\' \c;, ~tneev k th.!: rckd Sot!/- ~: }s ~ ~s <fa r.~; TIME 7 t, fiN'" b-kV1 'l~oo d - 4G:,CJ o EX/GRAD/FILLING o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o ~ ~2>th.ee-v ~v<.. Owner/Contr: -9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. INSNOTI 'EQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! CITY OF PRIOR LAKE INSPECTION NOTICE TIME SCHEDULED '0 : ~o ADDRESS OWNER CONTR. /YJ- 5'& PHONE NO. PERMIT NO. "tlPLUMBING Rid} 0 EX/GRAD/FILLING ,.fJ MECH RI c..::Y' 0 COMPLAINT o WATER HOOKUP 0 FIREPLACE RI o SEWER HOOKUP 0 FIREPLACE FINAL o PLUMBING FINAL 0 GASLlNE AIR TST o MECH FINAL 0 COMMENTS: 1?6-'(3 t;4'1- A, e- ~ ~~ F,YA( o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION ~W'pRK SA TISFAC R. PROCEED \ o .CORRECT ACl: A PROCEED o CORRECT W OR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! INSNOTJ PRIOR LAKE INSPECTION RECORD SITE ADDRESS 4 ~B5 \:=OU~, lA-l-J H-{l_~5 bi<~ N.c. NATURE OF WORK ' NEvJ CoKet6'Lc-'A-L USE OF BUILDING ""E:l2-c-p..,Nlll..c · t PERMIT NO. 00 - +~ DATE ISSUED ~ (t"Z- 00 CONTRACTOR W E:NS co. lNc , NOTE: THIS IS NOT A PERMIT FOR ANY OF THE INSPECTION THE PERMIT B S P4RAT DOGUM T OOfO~ 1 7jf1 0'0 7 /~{/D 1"'.q;~E 7J;?I1/VI' ING ""'lfl.l . 7" 7.OD.J 1-II-iJlJ 7 II w flvr-f. DEPARTMENT OF BUILDING AND INSPECTION FOUNDATION (Prior to Backfill) PLACE NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED ROUGH - INS SEWER I WATER I SEPTIC FRAMING INSULATION ELECTRICAL PLUMBING ~ HEATING (if required)b).b .lOb Ctlf.t,\ rl..!:rLAC~ GAS LINE AIR TEST ..:>. E, l / - 3---00 COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED I WALLBOARD I I FINALS fJ.JE ~-. 1./. 0 / GRADING (Prior to Sodding) BUILDING ~ .c,. ELECTRICAL PLUMBING HEATING DO NOT OCCUpy UNTIL ABOVE HAS BEEN SIGNED NOTICE This card must be posted near an electrical service cabinet prior to rough-in inspections and maintained until all inspections have been approved. On buildings and additions where no service cabinet is available, c~rd .;hall be placed near main entrance. to/- Call between 8:00 ar.~.i:OO A.M. for all inspections FOR ALL INSPECTIONS (612) 447-9850