HomeMy WebLinkAbout04-90
16200 Eagle Creek Avenue S.E.
Prior Lake, MN 55372-1714
PRELIMINARY PLAT
RESOLUTION 04-90
RESOLUTION OF THE PRIOR LAKE CITY COUNCIL APPROVING THE PRELIMINARY PLAT OF "HERITAGE
LANDING" SUBJECT TO THE CONDITIONS OUTLINED HEREIN.
WHEREAS:
WHEREAS:
WHEREAS:
WHEREAS:
WHEREAS:
WHEREAS
WHEREAS:
MOTION BY: PETERSEN
SECOND BY: ZIESKA
The Prior Lake Planning Commission conducted a public hearing on April 26, 2004 to consider an
application from Tradition Development for the preliminary plat of Heritage Landing; and
The Planning Commission further considered this matter at their meeting on May 10, 2004; and
Notice of the public hearing on said preliminary plat has been duly published and posted in accordance
with the applicable Minnesota Statutes and Prior Lake Ordinances; and
All persons interested in this issue were afforded the opportunity to present their views and objections
related to the preliminary plat of Heritage Landing for the record at the Planning Commission hearing; and
The Planning Commission and City Council have reviewed the preliminary plat according to the applicable
provisions of the Prior Lake Zoning and Subdivision Ordinances and found said preliminary plat to be
consistent with the provisions of said ordinances; and
The Prior Lake City Council considered an application for preliminary plat approval of Heritage Landing on
May 17, 2004; and
The City Council finds the preliminary plat of Heritage Landing to be consistent with the provisions of the
Zoning and Subdivision Ordinance, subject to the listed conditions.
NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY OF PRIOR LAKE,
MINNESOTA:
A. The above recitals are incorporated herein as if fully set forth.
B. The preliminary plat of Heritage Landing is approved subject to the following conditions:
1) The landscaping plan should be revised to meet all ordinance requirements. Replacement trees must be included
on the landscaping plan.
2) The private streets must be platted as outlots. An 13' wide drainage and utility easements must be provided on
either side of the outlot.
3) The developer must provide easements for the storm water pond.
4) Provide full-scale building elevations and floor plans, including height and building materials.
5) Provide the required calculations for impervious surface and floor area ratio.
r: \resoluti\plames \2 004\04-90. doc
~~i~ofpriorlake.com
Phone 952.447.4230 / Fax 952.447.4245
6) Include Outlot A as parkland. Also, revise the configuration of the proposed park so the west boundary is an
extension of the easterly lot line for Unit 9. Include calculations of the net area (less wetlands) to be dedicated as
park. Parkland must be identified as Park on the final plat.
7) Address the following Engineering issues:
General
a. Show the City project # 03-42 on all plan sheets
b. Show utility easement for all utilities and pond.
c. The final plans should follow the requirements of the Public Works Design Manual.
Gradina and Erosion Control
d. Show top and bottom of wall elevations.
e. The pond access should have a maximum grade of 8%.
f. Show EOF for street drainage.
g. Verify that drainage structures 0 are to be catch basins.
Hydroloaic/Hydraulic and Water Quality
h. Provide storm sewer pipe sizing calculations.
i. The pond sizing should be for the 100 year storm.
Watermain
j. Loop the watermain so that there are no dead end lines. Revise connection point on 170th Street north of unit
10.
k. Straighten watermain connection point at west entrance.
I. Provide watermain to the west property line.
Sanitary Sewer
m. Provide sanitary sewer to the west property line.
Storm Sewer
n. Use RCP for pond outlet.
Streets
o. Show proposed street location and proposed sidewalk along 170th Street.
Passed and adopted this 17th day of May, 2004.
Hau en
Blomber
LeMair
Petersen
Zieska
YES
X
X
X
X
X
NO
{Seal}
r: \reso luti\planres \2 004\04-90. doc
Page 2