Loading...
HomeMy WebLinkAboutBuilding Permit 04-0209 CITY OF PRIOR LAKE BUILDING PERMIT, TEMPORARY CERTIFICATE OF ZONING COMPLIANCE AND UTILITY CONNECTION PERMIT Date Rec' d 3. z,+. 04-- I. White File 2. Pink City 3. Yellow Applicant I PERMIT NO. 04--,ozo9'1 ;- I ~;S~Prim~dUgn .tOOUomJ '. C 2.. ~ t?a. ~hJ &~~ LEGAL DESCRIPTION (office use only) LOT BLOCK ADDITION (Phone) I OWNER (Name) (Address) V~~P6I--r.s ~~-t ZONING (office use) K!/SO PID BUILDER (Name) (Contact Name) (Address) (Phone) PItAI.~) o;,C-2-- {?Y-?a (S e; G"'l.. .;. o/*Y- ~ / /' ~ 2.~G Cv TYPE OF WORK o New Construction OLower Level Finish o Misc. cOB'''; o Porch ORe-Roofing ORe-Siding o Fireplace OAddition OAlteration OUtility Connection PROJECT COST IV ALUE (excluding land) $ I hereby certify that I have furnished information on this application which is to the best of my knowledge true and correct, I also certify that I am the owner or authorized agent for the above-mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building official can revoke this permit for just cause. Furthermore, I hereby agree that the city official or a designee may ;~JZ~4ons Signature Permit Valuation Permit Fee $ Plan Check Fee $ State Surcharge $ Penalty $ Plumbing Permit Fee $ Mechanical Permit Fee $ Sewer & Water Permit Fee $ Gas Fireplace Permit Fee $ ~;:;;;mngp~Wben~ Building Official Date 2,c/2 ~~'73 Contractor's License No, ~~y Park Support Fee # $ SAC # $ Water Meter Size 5/8"; I"; $ Pressure Reducer $ City SAC and WAC # $ Water Tower Fee # $ Builder's Deposit $ Other $ TOTAL DUE $ /Zz ,lD7' I Paid ~~~~ . Date -_ ---- ;;).- - _- I ~;e~'::~ll b I This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and may proceed as requested. This document when signed by the City Planner constitutes a tempor3!Y Certificate of Zoning compliance and allows construction to commence. Before occupancy, a Certificate of Occupan~ must be Woed.. _ ?:>.?J1-0tJ- ~d~ ~~ f:ir Date Special Conditions, if any -;- 24 hour notice for all inspections (952) 447-9850, tax (952) 447-4245 16200 Eagle Creek Avenue Prior Lake, MN 55372 / \ -' White - Building Canary - Engineering c. xlnk . ~ Planrd..~ The ('enter or the tlke Country BUILDING PERMIT APPLICATIONOEPARTMENT CHECKLIST NAME OF APPLICANT APPLICATION. RECEIVED TH E {J E CK- L-Ic t -l \/' ,~. 2.4-. (4-- The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: 14-&24- CAtLr\"J0 B[t\u-t ~. Acceptedt Accepted With Corrections Denied Reviewed By: ~ Comments: Date: 3 r 31 . (J\..f 4-U-rt;a& P-h ~ to fde__ UYJ~ f U-JL +h f~~ *- 0 .~ uYJp.e,rYl QLu) I ~ ~wcd ~yC){{c..~ liThe issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. II The ('enter of the tab Country qhite - Buildi~ anary - Engmeering Pink - Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT APPLICATION RECEIVED TH~ DGCj:: CJlzVJ 3 . z4-. Q4- The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: I t}& Z4- OAt:LAND Accepted With Corrections BE:A~. /' Accepted Denied Q_ .. ~ /1... Reviewed By: ~ ~ 4rIL ~ -/L,-J~c-J-, ~~8.R.. ~ ~ A~ Date: 3/3a/o'l I t - 8 ., ., (0 w~ .l.Jt-~....,...) Comments: liThe issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid.1I IH,.R- 26- 2004 15: 16 ULTEIG MPLS 7635711168 P.02 CONSULTING ENGINEERS SINCE 1944 UL TEIG ENGINEERS t INC. OTHER OFFICES: FARGO, NO BISMARCK. NO SIOUX r:l.U.S. SO 5201 EAST RIVE~ ROAD. SVITE 308 PHONE; 1&3.S71.2S00 MINNEAPOLIS. MN 55421 FAX: 763.~7"'1'8 WEB SITE: www.u1t.ig.Com March 26, 2004 The Deck Crew 18266 EvenerVVay Eden Prairie, MN 55346 Attn: Mark Pahl Re: General Review of Glass Handrails use in New Deck Construction UEI Project No. 204.269 Dear Mr. Pahl: The purpose of this letter is to report the findings of a structural engineering review of the use of tempered glass in deck railing panels. ASSIGNMENT Ulteig Engineers Inc. (UEI) has been retained to provide a structural engineering review of the tempered glass that The Deck Crew uses in the construction of handrails on new decks as directed by Mark Pahl. BACKGROUND Mark Pahl, of The Deck Crew, constructs several decks and patios throughout the Twin Cities Metro Area. He has encountered several situations where the City Inspections Department requires a Registered Engineer to verify the tempered glass used on the railings is structuratly adequate and meets the requirements of the Code. Mark Pahl wishes to have an independent structural engineering review of the tempered glass placement within the handrail system. OBSERVATIONS AND COMMENTS 1. The following information was provided to Jason Hanlon on March 25, 2004 by Mark Pahl: a. The glass is ~" tempered glass per ASTM E 1300 b. The overall height of the glass will range between a 33.75" minimum and a 35.5" maximum. eQUAL OPPORTUNITY EMPLOYER :IAR-26-2004 15: 16 . ULTEIG MPLS 7635711168 P.03 The Deck Crew March 26,2004 UEI Project No, 204.369 Page 2 c. The overall length of the glass will range between a 22" minimum and a 60" maximum. d. The design loading shall be 90 mph wind, Exposure B with a 3-second gust, per the 2003 Minnesota State Building Code with the amended 2000 International Residential Code (IRe) e. The glass will be supported evenly at the top and the bottom. f. The railing members will be structurally adequate to support the design loads and designed by others. PROFESSIONAL OPINION 2. It is my professional engineering opinion that: a. The 1/4" tempered glass will be structurally adequate to support a 90mph wind load, Exposure B, within the limits described above. GENERAL 3. The information, observations, and opinions stated in this report are based on information provided to Jason Hanlon. 4. The observations and opinions expressed in this report were based on my professional engineering judgment and professional practice. If you have any questions. please contact me. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly licensed professional e neer under e aws of the State of Minneso . TOTAL P.03 /', ~/.". ~.., .' PRIOR LAKE DEPARTMENT OF BUILDING AND INSPECTION INSPECTION RECORD SITE ADDRESS ~., TYPE OF WORK b&tJ'. · USE OF BUILDING ,f:' o. \ PERMIT NO. DATE ISSUED BUILDER C PHO E #jSl- fl'l-3/" NOTE: THIS IS NOT A PERMIT FOR ANY OF THE INSPECTIONS BELOW THE PERMIT IS BY SEPARATE DOCUMENT IN8PE~ DATE I FOOTING I j/l7y I. 4-7-0(;,1 I PLACE NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED _ I I I I FINAL I ~ I I FOR~LL INSPECTIONS (952) 447-9850 _ to; ~ ._, DATE nilE CITY OF PRIOR LAKE INSPECTION NOTICE SCHEDULED ~ -u Ofk~~ 64A.. ,) ADDRESS ~l i OWNER CONTR. PERMIT NO. 2o~ PHONE NO. o FOOTING o FOUNDATION o FRAMING o INSULATION -r:f'FINAL o SITE INSPECTION o PLUMBING RI o MECH RI o WATER HOOKUP o SEWER HOOKUP [] PLUMBING FINAL o MECH FINAL o EXlGRADIFILUNG o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o COMMENTS: /. LWORK SATISFACTORY, PROCEED o CORRECT ACTION AND PROCEED o CORRECT WORK, CALL FOR REINSPECTION BEFORE COVERING Inspector: Owner/Contr: FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. 'MENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY/ INSNOTJ