HomeMy WebLinkAboutSURVEY LEDGER iii-4V 1 4 - 1 0 .s 5
PI eNEERengineering
CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS
2422 Enterprise Drive, Mendota Heights, MN 55120, Phone: (651) 681 1914 Fax: (651) 681 9488 - Pioneereng.com
Certificate of Survey for: KEY LAND HOMES
ADDRESS: 16479 STEMMER RIDGE ROAD, PRIOR LAKE, MN
LOT AREA =14694 SF BUYER: MODEL MODEL: 3658 -II ELEVATION: A
HOUSE AREA = 2647 SF
DRIVEWAY AREA =917 SF
SIDEWALK AREA =118 SF 1
COVERAGE = 25.1%
(986.8)
"Ks.ENCH MARK:
CD •le- -Pe r y ke k(1‘) TOP OF SPIKE PROPOSED
I ELEV. = 993.30
0 \\
UNDER CONST. r)
M \ N88 °05'43 "W I i / I 10) 157. $0 ��
�% \ \\ (995.8) I 1�
I 9'3.8 994 35.29 \ 993.3 52.33 (986.8 (984.0) L°�
O �o a � M r� - ."O L ■=t.. - ••-••-• -..- '84.6 __ •I_ _1O -•• ••- ..- .. -.. -� 978.5
10 �I •• Kil I in- - -- - - - -1
1 w 0 a ., .1 993.8 I 991.7 I M � � 1 0 s...., �vl.� --- 1 ( 0 ••1.6 -
'�` ��, 986.0
M , i I /:�;J 993... _ ( 2 2; 8108z � •j- 27.66 X 985.2 • 0
•
.���i o c�/ 1 O
_ 9 . .! I - .° b N¢ ^ Q p
K i
LL •� 1 Iiu11 1i € t0 o 0) v) < tin 0)
u-� of / I
I W - - 35.5 -I= 22.00 • •2.6 0.V 0m 2.00 986.0 985.1
.I �r1ax��r a Imo' • :..o - x -- - 70.0 -
' O 11 / D °U M 1 I
1 C ° I 99 3.9 ,.� 2.7�/ ^ 1 0 1W -
W C 993.3 8 / -
^ ^ O c9 X 09
(V 0) '4" O .... I Z w N
1 O i 6 c0 6 0 9 0 � . Q a 0)
N 0) x 0) .
_ l
O) �9A O caw
Z . . ! v 993.7 ^ � �� d .Q Q
C 5 � it - - � Lri 32.33 - I o W O GNI
D 1 1 0 • I 1 985.9 I ` O X 984.6 1 (/)
.L - M I �1 0
i 992.9 d 993.1 - ..�.. �. .. - I 110
99 � 36.11 •
, 993.2 52 985.• 976.9
6 I c Ni ,' (993.9) (985.3) o
5 I 'Ig /'
rn 6
40 `� � o r 1 I rn
I L- ..
/ '� -100 `'
/ 0 1 I , I t
, PROPO Ico u
BENCH MARK: HOUSE
TOP OF SPIKE STAKED
ELEV.= 993.21
N88 °05'43 "W 158.21
APPROVED
E9uiidin _ ,, Date LOWEST ALLOWABLE FLOOR ELEVATION :986.4
Zoning �If , Date 6 z- HOUSE ELEVATIONS
Grading l : (PROPOSED) /ASBUILT
BENCH MARK: LOWEST FLOOR ELEVATION : (988.3) /
TOP NUT HYDRANTLOTS 1 -10 BLK 5 TOP OF FOUNDATION ELEV. : (997.1) /
ELEV.= 996.45
NOTE: ADD FOUNDATION LEDGE AS REQUIRED GARAGE SLAB ELEV. Q DOOR (9963) /
NOTE: GRADING PLAN BY LAST DATED 11/27/07 WAS USED
TO DETERMINE THE PROPOSED ELEVATIONS SHOWN ON THIS CERTIFICATE.
NOTE: PROPOSED BUILDING DIMENSIONS SHOWN ARE FOR HORIZONTAL
LOCATION OF STRUCTURES ON THE LOT ONLY. CONTACT BUILDER PRIOR TO
CONSTRUCTION FOR APPROVED CONSTRUCTION PLANS. DENOTES TREE
NOTE: NO SPECIFIC SOILS INVESTIGATION HAS BEEN PERFORMED ON THIS LOT
BY THE SURVEYOR. THE SUITABILITY OF SOILS TO SUPPORT THE SPECIFIC -..- DENOTES PROPOSED EROSION CONTROL
HOUSE PROPOSED IS NOT THE RESPONSIBILITY OF THE SURVEYOR.