Loading...
HomeMy WebLinkAboutBuilding Permit 11. 0505 Antennas i cD J IIIC z _ f;; 3 : a' W E r: V �f Z re W W a 0 w iPJL Wi > I c ui x O i 1,1 Ou. N 0 J zili — u .�'Y = z o 0Li ci F. 4 re H p . O 0 0 oq ~ ai a Q � 0 0 w m � � � m � a 0 U) CO 0 a 2xW 2x m , moi- goo W Q (E3 co J W v w w W jlj �' 0000 ❑a. \.1`[y, W a a LL � ` p J I g Q V -*) W W W ';1 V z0 11 Mb& h IQ Y V Z ` Q `'" co40 ti��ii � p Z O • �v\ N V 0 - o� vi a 3 o z 0 o w 1- 1 a 4 F., ~ p — a Z r N p c. O. CO z f- Zag -+ z IJ.I w w w c a C n = 00 p p p V Dui W a' W 4� Q V O G W p up,. up. u.ZlZ-i. U) 0 V V E. v ? Q 0 a 000000 0 0 0 PR/74.\\ �� CITY OF PRIOR LAKE BUILDING PERMIT, 4"(7/ .5,. Date Recd <1011[111., TEMPORARY CERTIFICATE OF ZONING COMPLIANCE �'' �.• U `� AND UTILITY CONNECTION PERMIT �/• `�, il Iy E SO 1.White File 2. Pink Cig- f PERMIT NO. / r I / 5153-1 (Please type or print and sign at bottom) 3.Yellow Applicant ADDRESS f j 1) LA i To t o, l t /� ST, 3t._ ZON]NG(office use) LEGAL DESCRIPTION(office use only) LOT BLOCK ADDITION a' ee PID as`6\0),0 2.LA 0 OWNER (Name) 147 lt21 (Phone) 6t2---C3931- °0 ') (Address) b.1;'it7---I (iV AL 1 to T'RIJL Gr2Uv_ mni s11I ( BUILDER (Company Name) \5it (Phone) (-)1 1.t'&S°l---01.t)9 (Contact Name)t` SL .Ve.T O JW (Phone) 6t I-—c6 5a_ 01,)01,)(e) (Address) V"l2 M-6.na(M cd cA ti1 1 fv 4p1._ Cr Vjt Nyv s-ckl i TYPE OF WORK 'New Construction ['Deck ['Porch [Re-Roo ' Addition arAlteration �Utili�, ❑Re-Siding Lower Level Finish Fireplace Connection CHANGING OUT 6 EXISTING COMMUNICATION ANTENNAS& CODE: QLR.C. .B.C. Mis RELATED EQUIPMENT WITH A NEW MODEL AND ADDING 3 Type Construction I II III ZV V A B ADDITIONAL ANTENNAS NO CHANGE TO GROUND EQUIPMENT Occupancy Group: ABE F HI MR 3 4 5 S U PROJECT COST/VALUE $ 10 l O cD • 0 O Division: 2 (excluding land) I hereby certify that I have furnished information on this application which is to the best of my knowledge true and correct. I also certify that I am the owner or authorized agent;:or the above-mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building official can r vke this rm11/1nit for just cause. Furthermore,I hereby agree that the city official or a designee may enter upon the property to perform needed inspections. X _ lal Signature Contractor's License No. S^U— U Date Permit Valuation Park Support Fee ## $ lot eo®r•- Permit Fee $ $ MI .54) SAC # Plan Check Fee $ 17-4 ,40 Water Meter Size 5/8"; 1"; $ State Surcharge $ S .— Pressure Reducer $ Penalty $ Sewer/Water Connection Fee # $ Plumbing Permit Fee $ Water Tower Fee # $ Mechanical Permit Fee $ ors Deposit/Lel A/D5-e./7-p& $ Sewer&Water Permit Fee $ 500. 0 6 Other l< f�L11 61)t1� $ foci Oa '- Gas Fireplace Permit Fee $ 1/44(7. 5 TOTAL DUE $ ' This Ai ti , , , s our Building Permit When ,, ov dPaid Re t 11Z�, 9b INo. (o3//� I Date 6. 2.49,// B . g,_ A. 0it r( :utldt,_r_" •a= This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and mayproceed as when signed by the Ci Planner constitutes a temporary Certificate of Zoningcompliance and allows construction to commence. Before occupancy, requested. This mutt e issued. _Ar P a Certificate of Occupancy mu t be / Pl.. .,g Director Date Special Conditions,if any 24 hour notice for all inspections(952)447-9850,fax(952)447-4245 4646 Dakota Street S.E.,Prior Lake,Minnesota 55372 ,..r-.,•,t.n ,>,,,.._, ..er,..,,m .,vim u•' .7.a.,.n..."aX-'.a,M k:,,.r.., yyb:,y a✓'...ETsak h�•;. . _ ,Me.�',;•y...:+h.•-a+ ..rrvq+. .x=rerr.o.,,:,.:.t. A. d '.^�S .r r Ito F ,.x -... e�:. 04 PRIp� 4 C..3' turf White -Building �'rNNES��P Canary -Engineering Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT ti APPLICATION RECEIVED `fM. - / / The Building, Engineering, and Planning Departments have reviewed the building permit: application for construction activity which is proposed at: yi l / 6 i x: . 1 1 ! Accepted Accepted With Corrections Denied Reviewed By: / Date: 6'—Ci2 I'.1/ Comments: "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." Oi PRI°4 � N t") txrl White -Building . TNESO�P Canary Engineeringnin Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT /1 / S / APPLICATION RECEIVED 5. S. / I The Building, Engineering, and Planning Departments have reviewed the building permit: application for construction activity which is proposed at: 4-744 / D w6/2 S i RE6 . Accepted v Accepted With Corrections Denied Reviewed By: Date: 5-7Z371 Comments: 1- £ c. Oztt.5 t I norri-tii C4lT- A7 - Li 3_ A. pr c ousro.orc- e C. , 15A)Le w ttw Arrt, Tit a. - tokArr A 4 1A — -4 t A- CI,}1 Et4. -e.0-k u&&, I mac. "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." PERMIT TRACKING FORM Address: .14"7"--/ 7f'w'672.. ST. Description: ,49,f,0/1 -7.1/•/A Application Received:,. 6. c f! Date Days Elapsed Initial Review Conducted Applicant Called with Corrections Corrections Received I/ Corrections Reviewed Final Review Applicant Called Date Days Elapsed 4 • Date Reviewed Initial Review Completed Corrections Received Corrections Reviewed Final Review Applicant Called Date Days Elapsed -.4,„ Date Received Initial Review Completed Corrections Received Corrections Reviewed Final Review Applicant Called Initial Review Time Correction Review Initial Application Date Final Corrections Received: Applicant Called VV/Corrections: Final Applicant Call Date: Total Days Elapsed: Total Days Elapsed: 'PRIOR DEPARTMENT OF BUILDING AND INSPECTION INSPECTION RECORD SITE ADDRESS 4 ( 1:3-4442- . TYPE OF WORK ,4,t,,. ,r,iA USE OF BUILDING l /r A /� PERMIT NO. tj_ 505. DATE ISSUED E ,1 _ BUILDER p y-+-,- PHONE # 45/2-851- 9707 NOTE: THIS IS NOT A PERMIT FOR ANY OF THE INSPECTIONS BELOW THE PERMIT IS BY SEPARATE DOCUMENT INSPECTOR DATE I FOOTING PLACE NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED tel F1A I - I FINAL FOR ALL INSPECTIONS (952) 447-9850 4 KLM ENGINEERING INC. l'.O lox 897•3394 Lake I;Imo.Ave. N.•bake I:Imo.MN '55(42 (()5I)773-511 I •I ax(651)773-5222 June 20,2014 By Email Only: Nick Zurbey Public Works Technician City of Prior Lake 17073 Adelmann St. SE Prior Lake,MN. 55372 RE: Final Walk through Inspection/Punch List on the Tower Street Water Tower in the City of Prior Lake,MN AT&T site MNL0344,KLM Project MN 2819. Dear Mr.Zurbey: KLM Engineering Inc.performed a final walk through/punch list on the above mentioned tower in Prior Lake,MN and has the following comment: KLM Engineering Inc.found the install to be completed per the approved drawings and found no coating damage or areas that will require repair. Please consider this letter as verification that the scope of work detailed in the above mentioned drawings has been completed and approved. The above punch list has been prepared by Rodney Ellis of KLM Engineering Inc.and constitutes his understanding of issues unresolved for completion of the project. The owner reserves the right to add to or modify this list to meet their requirements. If you have any comments,questions or corrections concerning these issues,please contact the undersigned in writing immediately. Sincerely, KLM Engineering,Inc. Rodney Ellis Telcomm Supervisor CC: Michelle Nelson,KLM\Office File KLM ENGINEERING, INC. Invoice P.O.Box 897 3394 Lake Elmo Ave.N. DATE INVOICE NO. Lake Elmo,MN 55042 6/4/2014 5218 CUSTOMER PROJECT DESCRIPTION City of Prior Lake AT&T LTE Antenna Upgrade 4646 Dakota St. SE Tower Street Tower Prior Lake,MN 55372 Prior Lake,MN Attn: Joe Witta Installation Inspection P.O. NO. TERMS PROJECT Net 15 MN2819 AT&T DESCRIPTION QTY RATE AMOUNT Antenna Inspection Services-Fixed Fee 1 5,000.00 5,000.00 UHT AUG 0 7 2014 • Make all checks payable to KLM ENGINEERING,INC. For questions call Rod Ellis at(651)773-5111 Total $5,000.00 ,4 .ur , 4 '� _ )4121 lo,_ valcl(nn,Pl 5117 i) i111 .1 2' June 5, 2014 Katy Gehler U.S. Mail City of Prior Lake 17073 Adelmann Street SE Prior Lake, MN 55372 RE: Project Closeout for the AT&T Upgrade on the Tower Street Tower Located in Prior Lake,Minnesota KLM Project Number: MN 2819 AT&T Site Number: MNL03434 Dear Ms. Gehler, The upgrade for AT&T on the Tower Street Tower located in Prior Lake, Minnesota has been completed per the specifications for the project. KLM recommends that the City of Prior Lake accept this project as complete. Enclosed are copies of KLM's documentation in regards to this project. It has been a pleasure working with the City of Prior Lake, and we look forward to future projects with you. If you have any concerns,please call me at 651.773.5111. Sincerely, KLM Engineering,Inc. /r6( t Rodney Ellis Telecomm Project Supervisor End: Daily Inspection Paperwork Photo CD Invoice# 5218 C:ms/mydocs/antennas/MN2819PriorLakeLettero!Completion6-5-14 KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake, IPS shop insp Inspector: RJE Tower Name: South tower Foreman: Paul Date: Sat 10-20-12 Antenna Provider: AT&T No. of crewmembers on site: 2 Contractor's plans for the day: IPS shop requested inspection to apply primer coat to the antenna panels for the above mentioned tower Crewmembers location/activity 1 2 primer coating 2 Results of inspection: Panels were hand sanded, and wiped with denatured alcohol prior to priming Were rejected areas repaired? n/a Explain: None Observed blow down? Yes Observed mixing of paint? Yes Additional Comments: Primer coat-Sherwin Williams/Procryl; batch#XM0452EC In shop constant weather conditions, 60 degrees,40% humidity. Primer was applied to the steel pieces yesterday with Tnemec series 161, part A; ba2012080059t part B; kc2012090769. DFT of the 2n6 coat on the steel pieces average 7-8 mils. Finish coat (tnemec falling blue) is expected to be applied next Wednesday. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No. MN2819 City: Prior Lake Inspector: Dewey Prinzing Tower Name: Power Street Contractor: IPS Date: 11-19-12 Foreman: Paul Antenna: ATT No. of crewmembers on site: 5 Contractor's plans for the day:Apply Zinc and intermediate coat of paint to steel components. Crewmembers location/activity 1/foreman Keep projects organized 1/painter Paint parts in booth 3/floor Put parts on/off painters rail Results of inspection: The surface profile was good on all the parts. Were rejected areas repaired? NA Explain: Observed blow down? Observed mixing of paint? Yes Additional Comments: The anchor profile is 3.1, Temperature was 69 and Humidity was 44% Primer coat on steel components is Tnemec 91h20 A KC2012000120 B KC2012088069 Intermediate coat is Tnemec 69 A KC2012070395 B KC2012090110 Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake Inspector: RJE Tower Name: Tower St Foreman: Paul Date: 11-21-12 Antenna Provider: AT&T No. of crewmembers on site: shop Contractor's plans for the day: Finish coat the steel for Prior Lake/AT&T/tower street tower Crewmembers location/activity 1 1 Finish coating 2 3 4 5 6 7 8 Results of inspection: DFT readings on the intermediate coat ranged from 5.2-6.6. no deficiencies were found Were rejected areas repaired? n/a Explain: n/a Observed blow down? Yes Observed mixing of paint? Yes Additional Comments: Finish coat today is tnemec 73, part A; kc2012090571, part B; kc2012098539. Finish coat is being applied at 8 wet mils. Weather conditions are typical shop conditions. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake, MN Inspector: Scott Kriese Tower Name: Tower St EWT Contractor: Mill City Date: November 30, 2012 Foreman: Josh Antenna: AT&T KLM on site: Yes No. of crewmembers on site: 3 Contractor's plans for the day: Continue to install the new AT&T antennas and swap out the existing antennas. Crewmembers location/activity Exterior leg Antenna install Exterior Ground Support Exterior Crane Results of inspection: I found that the install was being completed to the specification and found not defects or areas to reject. Were rejected areas repaired? N/A Explain: N/A Observed blow down? N/A Observed mixing of paint? N/A Additional Comments: The crew estimates that they will be completed with the upgrade by Wednesday of next week. After meeting with the crew and viewing what had been completed so far I left the site for the day as the crew continue to work. I downloaded photos and completed paperwork off site today. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake, MN Inspector: Scott Kriese Tower Name: Tower St EWT Contractor: Mill City Date: December 4, 2012 Foreman: Josh Antenna: AT&T KLM on site: Yes No. of crewmembers on site: 2 Contractor's plans for the day: Two crewmembers completed installing the hybrid cable today. Crewmembers location/activity Exterior leg Antenna install JLG Lift Cable installation Results of inspection: I traveled to the site today and viewed the installation of the parts and cables. I found that tape,neoprene, and cluster mounts were being used as specified and they were using the correct bracketing that exists on the tower. Were rejected areas repaired? N/A Explain: No defects found. Observed blow down? N/A Observed mixing of paint? N/A Additional Comments: The installationphase of this project is completed. The crew will need to return in the spring of 2013 to perform the prepping and coating work on the new antenna brackets. I completed paperwork and downloaded photos off site today. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Job No: MN2918 City: Prior Lake, MN Inspector: Scott J Kriese Tower Name: Tower St Tower Contractor: Osseo Contracting Date: May 22, 2014 Foreman: John Larson Antenna: AT&T KLM on Site? Yes No. of Crew on site: 2 Contractor's plans for the day: The crew plans on abrasive blasting and priming the areas around the new support and antenna brackets on the south leg of the tower today. Crewmembers locations/activities Ground-1 Support/Equipment Exterior Leg-1 Blast/Prime Results of inspection: I found the blast to look good today with no defects present. The coating feathered out with the blast media and DA sanding was not required. Were rejected areas repaired? N/A Explain: No defects found. Observed blow down? Yes Observed paint mixing? No Additional Comments: The temperature was 67 degrees, the RH was 37%, and the dew point was 36. The crew used a Sullair 185 to perform the blasting today and the compressor passed a blotter test. They applied the coating with a brush and roller. The coating applied today was Tnemec Series N140 1255 Beige. The batch numbers are Part A-BA2013080176 and Part B- KC2013081118. No thinner was used today. The crew informed me that they would return tomorrow and complete the rest of the coating application. Page 1 of 1 KLM Engineering Daily Inspection Report KLM Job No: MN2918 City: Prior Lake, MN Inspector: Scott 1 Kriese Tower Name: Tower St Tower Contractor: Osseo Contracting Date: May 23, 2014 Foreman: John Larson Antenna: AT&T KLM on Site? Yes No. of Crew on site: 2 Contractor's plans for the day: The crew plans on applying the intermediate coat on the areas primed yesterday. Crewmembers locations/activities Ground-1 Support/Equipment Exterior Leg-1 Coating application Results of inspection: I took DFT readings and performed a visual inspection today and found no defects present. The mils ranged from 3.1 mils to 4.5 mils and averaged approx. 3.5 mils of primer. Were rejected areas repaired? N/A Explain: No defects found. Observed blow down? N/A Observed paint mixing? Yes Additional Comments:The temperature was 73 degrees, the RH was 46%, and the dew point was 38. . They applied the coating with a brush and roller. The coating applied today was Tnemec Series N140 1255 Beige. The batch numbers are Part A-BA2013080176 and Part B- KC2013081118. No thinner was used today. The crew informed me that they would return next Tuesday and apply the final coat. Page 1 of 1 }� x rt �� 42,z,� i" )i e . Llitsia,fel`.�i0� June 5, 2014 Katy Gehler U.S. Mail City of Prior Lake 17073 Adelmann Street SE Prior Lake, MN 55372 RE: Project Closeout for the AT&T Upgrade on the Tower Street Tower Located in Prior Lake,Minnesota KLM Project Number: MN 2819 AT&T Site Number: MNL03434 Dear Ms. Gehler, The upgrade for AT&T on the Tower Street Tower located in Prior Lake, Minnesota has been completed per the specifications for the project. KLM recommends that the City of Prior Lake accept this project as complete. Enclosed are copies of KLM's documentation in regards to this project. It has been a pleasure working with the City of Prior Lake, and we look forward to future projects with you. If you have any concerns,please call me at 651.773.5111. Sincerely, /10/111 t� �_� to c--0 /(� -- KLM Engineering,Inc. C6�Ft�to �5 dvl �ise Pclin�i^� ut- awl 1 r ��vtcc b15r�'cI;: �1 Rodney Ellis ti1L4 j ?c,, mt,+- Telecomm Project Supervisor 4 y _z/ .3 End: Daily Inspection Paperworkretut iS Photo CD tw Invoice# 5218 _ ,r.vwP,, of Lt 1—Q. e-0 �Zre-c4-4,v4 C:ms/mydocs/antennas/MN2819PriorLakeLetterofCompletion6-5-14 �� Acce 2-6° —tv t0vO wn lL Q"cter ,1-7-1 . Zo 1 ? "J0V t KLM ENGINEERING, INC. Invoice P.O. Box 897 DATE INVOICE. NO. 3394 Lake Elmo Ave. N. Lake Elmo,MN 55042 1/16/2013 4741 CUSTOMER PROJECT DESCRIPTION City of Prior Lake AT&T LTE Antenna Upgrade 4646 Dakota St. SE Tower Street Tower Prior Lake,MN 55372 Prior Lake, MN Attn: Joe Witta Installation Inspection P.O. NO. TERMS PROJECT Net 15 MN2819 AT&T DESCRIPTION QTY RATE AMOUNT Antenna Inspection Services -Fixed Fee 1 5,000.00 5,000.00 Jaize, I s-f1145 viva i,,i -? (4r4-T, T« e (Aitt‘ 6 lel SPkOion NT01` - CCE fnE JUN 7 2013 11 NEERING, INC. For questions Total $.5,000.00 call Laurie Sylte at (651) 773-5111 KLM ENGINEERING, INC. Invoice P.O. Box 897 3394 Lake Elmo Ave.N. DATE INVOICE NO. Lake Elmo, MN 55042 6/4/2014 5218 CUSTOMER PROJECT DESCRIPTION City of Prior Lake AT&T LTE Antenna Upgrade 4646 Dakota St. SE Tower Street Tower Prior Lake,MN 55372 Prior Lake, MN Attn: Joe Witta Installation Inspection P.O. NO. TERMS PROJECT Net 15 MN2819 AT&T DESCRIPTION QTY RATE AMOUNT Antenna Inspection Services-Fixed Fee 1 5,000.00 5,000.00 Make all checks payable to KLM ENGINEERING, INC. For questions Total call Rod Ellis at(651) 773-5111 $5,000.00 t ( KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake, IPS shop insp Inspector: RJE Tower Name: South tower Foreman: Paul Date: Sat 10-20-12 Antenna Provider: AT&T No. of crewmembers on site: 2 Contractor's plans for the day: IPS shop requested inspection to apply primer coat to the antenna panels for the above mentioned tower Crewmembers location/activity 1 2 primer coating 2 Results of inspection: Panels were hand sanded, and wiped with denatured alcohol prior to priming Were rejected areas repaired? n/a Explain: None Observed blow down? Yes Observed mixing of paint? Yes Additional Comments: Primer coat-Sherwin Williams/Procryl; batch#XM0452EC In shop constant weather conditions, 60 degrees,40% humidity. Primer was applied to the steel pieces yesterday with Tnemec series 161, part A; ba2012080059, part B; kc2012090769. DFT of the 2° coat on the steel pieces average 7-8 mils. Finish coat (tnemec falling blue) is expected to be applied next Wednesday. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No. MN2819 City: Prior Lake Inspector: Dewey Prinzing Tower Name: Power Street Contractor: IPS Date: 11-19-12 Foreman: Paul Antenna: ATT No. of crewmembers on site: 5 Contractor's plans for the day:Apply Zinc and intermediate coat of paint to steel components. Crewmembers location/activity 1/foreman Keep projects organized 1/painter Paint parts in booth 3/floor Put parts on/off painters rail Results of inspection: The surface profile was good on all the parts. Were rejected areas repaired? NA Explain: Observed blow down? Observed mixing of paint? Yes Additional Comments: The anchor profile is 3.1, Temperature was 69 and Humidity was 44% Primer coat on steel components is Tnemec 91h20 A KC2012000120 B KC2012088069 Intermediate coat is Tnemec 69 A KC2012070395 B KC2012090110 Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake Inspector: RJE Tower Name: Tower St Foreman: Paul Date: 11-21-12 Antenna Provider: AT&T No. of crewmembers on site: shop Contractor's plans for the day: Finish coat the steel for Prior Lake/AT&T/tower street tower Crewmembers location/activity 1 1 Finish coating 2 3 4 5 6 7 8 Results of inspection: DFT readings on the intermediate coat ranged from 5.2-6.6. no deficiencies were found Were rejected areas repaired? n/a Explain: n/a Observed blow down? Yes Observed mixing of paint? Yes Additional Comments: Finish coat today is tnemec 73,part A; kc2012090571, part B; kc2012098539. Finish coat is being applied at 8 wet mils. Weather conditions are typical shop conditions. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake, MN Inspector: Scott Kriese Tower Name: Tower St EWT Contractor: Mill City Date: November 30, 2012 Foreman: Josh Antenna: AT&T KLM on site: Yes No. of crewmembers on site: 3 Contractor's plans for the day: Continue to install the new AT&T antennas and swap out the existing antennas. Crewmembers location/activity Exterior leg Antenna install Exterior Ground Support Exterior Crane Results of inspection: I found that the install was being completed to the specification and found not defects or areas to reject. Were rejected areas repaired? N/A Explain: N/A Observed blow down? N/A Observed mixing of paint? N/A Additional Comments: The crew estimates that they will be completed with the upgrade by Wednesday of next week. After meeting with the crew and viewing what had been completed so far I left the site for the day as the crew continue to work. I downloaded photos and completed paperwork off site today. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Project No.: MN2819 City: Prior Lake,MN Inspector: Scott Kriese Tower Name: Tower St EWT Contractor: Mill City Date: December 4, 2012 Foreman: Josh Antenna: AT&T KLM on site: Yes No. of crewmembers on site: 2 Contractor's plans for the day: Two crewmembers completed installing the hybrid cable today. Crewmembers location/activity Exterior leg Antenna install JLG Lift Cable installation Results of inspection: I traveled to the site today and viewed the installation of the parts and cables. I found that tape,neoprene, and cluster mounts were being used as specified and they were using the correct bracketing that exists on the tower. Were rejected areas repaired? N/A Explain: No defects found. Observed blow down? N/A Observed mixing of paint? N/A Additional Comments: The installationphase of this project is completed. The crew will need to return in the spring of 2013 to perform the prepping and coating work on the new antenna brackets. I completed paperwork and downloaded photos off site today. Pg 1 of 1 KLM Engineering Daily Inspection Report KLM Job No: MN2918 City: Prior Lake, MN Inspector: Scott J Kriese Tower Name: Tower St Tower Contractor: Osseo Contracting Date: May 22, 2014 Foreman: John Larson Antenna: AT&T KLM on Site? Yes No. of Crew on site: 2 Contractor's plans for the day: The crew plans on abrasive blasting and priming the areas around the new support and antenna brackets on the south leg of the tower today. Crewmembers locations/activities Ground-1 Support/Equipment Exterior Leg-1 Blast/Prime Results of inspection: I found the blast to look good today with no defects present. The coating feathered out with the blast media and DA sanding was not required. Were rejected areas repaired? N/A Explain: No defects found. Observed blow down? Yes Observed paint mixing? No Additional Comments:The temperature was 67 degrees, the RH was 37%, and the dew point was 36. The crew used a Sullair 185 to perform the blasting today and the compressor passed a blotter test. They applied the coating with a brush and roller. The coating applied today was Tnemec Series N140 1255 Beige. The batch numbers are Part A-BA2013080176 and Part B- KC2013081118. No thinner was used today. The crew informed me that they would return tomorrow and complete the rest of the coating application. Page 1 of 1 KLM Engineering Daily Inspection Report KLM Job No: MN2918 City: Prior Lake, MN Inspector: Scott J Kriese Tower Name: Tower St Tower Contractor: Osseo Contracting Date: May 23, 2014 Foreman: John Larson Antenna: AT&T KLM on Site? Yes No. of Crew on site: 2 Contractor's plans for the day: The crew plans on applying the intermediate coat on the areas primed yesterday. Crewmembers locations/activities Ground-1 Support/Equipment Exterior Leg-1 Coating application Results of inspection: I took DFT readings and performed a visual inspection today and found no defects present. The mils ranged from 3.1 mils to 4.5 mils and averaged approx. 3.5 mils of primer. Were rejected areas repaired? N/A Explain: No defects found. Observed blow down? N/A Observed paint mixing? Yes Additional Comments: The temperature was 73 degrees, the RH was 46%, and the dew point was 38. . They applied the coating with a brush and roller. The coating applied today was Tnemec Series N140 1255 Beige. The batch numbers are Part A-BA2013080176 and Part B- KC2013081118. No thinner was used today. The crew informed me that they would return next Tuesday and apply the final coat. Page 1of1 ,fes KLM ENGINEERING INC. P.O.Box 897.3394 Lake Elmo Ave.N.•Lake Elmo,MN 55042 (651)773-5111•Fax(651)773-5222 July 13, 2011 By Email Only Joe Wiita Street and Utility Supervisor 17073 Adelmann St. S. E. Prior Lake, MN 55372-1714 RE: Second Review of the Proposed AT&T Antenna Upgrade on the Tower Street Water Tower Located in Prior Lake,AT&T Site MNL03434 KLM Project MN 2819 Dear Mr. Wiita: KLM has completed a second review of the proposed AT&T antenna installation on the Tower Street Water Tower, which included additional drawings Si, S2, S3 and the structural analysis by Krech Ojard &Associates. KLM has the following comments and recommendations for your use and to forward to AT&T: 1. Drawing C-2, details 1 and 2: There has been limited information provided on the power and fiber bundles. Are they to be enclosed within a conduit? How are the bundles attached and supported? It is not clear how visible the cables will be or if they will require painting, or if they are to match the existing cables. 2. The references on Details 1 on drawing C-2 should be modified to include the appropriate details on drawings S2 and S3. 3. Detail 2 on drawing C-3: Modify the references to include the appropriate details on drawings S2 and S3. 4. Details 3/S2 and 4/S2 show the surge suppressor mounting and Rosenberger box mounting details, respectively. While KLM recommends seal welded connections for these attachments to eliminate the potential for pack rust in areas inaccessible to coating, a 6-inch standoff is also recommended to enable painting behind the brackets when the box is temporarily removed during future reconditioning. 5. Drawings 51 and GN-1 each have painting notes, which appear to contradict each other in the coatings they recommend. Please delete the painting notes on drawing Si, and use the notes on drawing GN-1 6. The structural analysis provided by Krech Ojard& Associates appears to show the tower and supports can adequately support the additional applied loadings. These recommendations should be incorporated into the construction drawings and an updated copy provided for both your and our review. Following final review and approval, a preconstruction conference with AT&T representatives,their contractor and subcontractor(s),the City of Prior Lake and KLM should be scheduled to discuss the construction. If necessary,prior to construction, the contractor should provide welder's qualification certificates for our review. It should be relayed to the contractor that KLM will be performing inspections of the installation, and the contractor will need to contact KLM to schedule both field and shop inspections. Kelly Mulhern will be in charge of KLM's scheduling for this project. If you have any questions, feel free to contact him at 651-773-5111 or me at 218-849-1505. Sincerely, KLM Engineering, Inc. Matt Erickson, P.E. Manager of Engineering CC: Kelly Mulhern, KLM Engineering Enclosures: DT Prior Lake ATT MNL 03434 Tower St rev 1 7-7-11 KLM Redlines.pdf e:\mce\antenna\reviews 2011\MN 2819 Prior Lake Tower Street AT&T MNL03434 Second Review.doc