Loading...
HomeMy WebLinkAboutFire Sprinkler Test 2014 FIRE SPRINKLER , STEM Gi G I L B E R T INSPECTION & T STYREPORT Inspected By: Mitch Seybold Inspection Date: 09/02/2014 Inspection#: 1038 Property Name: VFW Post#6208 Bill To: VFW Prior Lake#6208 Property Address: 16306 Main Avenue SE Bill To Address: PO Box 116 Prior Lake, MN 55372 Prior Lake, MN 55372 Contact&Phone: 952-447-9220, Ed Speiker Was owner representative contacted prior to inspection? ❑Yes Q No . Representative's Name: Date Contacted: Rep present during inspection? ❑Yes ❑■ No Rep's Name: — Were all rooms available for inspection? Q Yes ❑ No Last inspection report available? ❑Yes Q No As-built drawings available? ❑ Yes 0 No Zone map available? 0 Yes ❑� No GENERAL SYSTEM INFORMATION 0 Date of Installation: No.of Systems: No.of Wet: No.of Dry: No.of Preaction: No.of Other: Location of Valve Assy: Under kitchen stairs INSPECTIONS Yes No N/A Other Yes No N/A Other SPRINKLER SYSTEM INSPECTION N/A ■ STANDPIPE&HOSE SYSTEM INSPECTION N/A FA Gauges(Dry,Preaction,Deluge) x _ _ Control Valves _ _ _ _ Waterflow Devices x _ Pressure Regulating Devices _ — _ — Valve Supervisory Devices x Piping — _ — — Supervisory Signal Devices(Except Valve) _ _ 7 _ Hose Connections — — — — Supervisory Switches _ — x _ Cabinet — — — — Gauges(Wet System) — _ _ Hose _ _ _ Hydraulic Nameplate x _ _ _ Hose Storage Device _ _ — ,_ Hanger/Seismic Bracing(Exposed Only) x Hose Nozzle — ,_ _ — Pipe&Fittings(Exposed Only) x _ _ _ PRIVATE FIRE SERVICE MAIN INSPECTION N/A Fl _ _ _ _ . Sprinklers _ Hose Houses _ _ _ _ Spare Sprinklers x — - _ Hose Hydrants(Dry Barrel&Wall) — — Fire Department Connection x _ Monitor Nozzles — _ _ _ Control Valves x ^ Hydrants(Wet Barrel) — _ _ — — Alarm Valves x Mainline Strainers — — — — _ Check Valves xPiping(Exposed) — — Pre-Action/Deluge — 7— _ Piping(Underground) _ _ _ _ Dry Pipe Valves x — _ Valves-Other — — Pressure Reducing&Relief _ _ Backflow Prevention Assemblies x SPRINKLER SYSTEM TESTING ' SUPERVISORY DEVICES Yes No Waterflow Devices Water Motor Gong: No.Present: Did the Alarm Sound? Q 0 Vane Type: Pressure Switch Type: 1 Do all waterflow devices operate properly? 0 ❑ Valves Supervisory Devices No.Present: n/a Do all supervisroy devices operate properly? Q lJ Supervisory Signal Devices No.Present: n/a Type: ANNUAL TESTS Main Drain Test Static: 84 PSI Residual: 83 PSI , Antifreeze Solution Specific Gravity at 60°F: n/a Freezing Point: °F Adjustment needed? ❑ ❑ •FIRE PUMP INSPECTION&TESTING(See fire pump inspection form) •WATER STORAGE TANK INSPECTION(See attached sheet) ■ WATER SPRAY FIXED SYSTEM INSPECTION(See attached sheet) ■ FOAM WATER SPRINKLER SYSTEM INSPECTION(See attached sheet) n Control valves left opened and system placed back in service. NOTES: Has a few recall heads _ Gilbert Mechanical Contractors,Inc.,4451 W 76th Street,Edina,MN 55435(952)835-3810 Page 1 of 2 R p Dry Pipe Valve Trip Test Report I L B E R T Gilbert Mechanical Contractors, Inc. 4451 West 76th Street L Edina, MN 55435 (952) 835-3810 Inspected By: Mitch Seybold Inspection Date:9/02/14 Inspection#: 1038 Property Name: VFW Post#6208 Bill To: VFW Prior Lake #6208 Property Address: 16306 Main Avenue SE Bill To Address: PO Box 116 Prior Lake, MN 55372 Prior Lake, MN 55372 Contact& Phone#: 952-447-9220. Ed Speiker Was owner representative contacted prior to inspection? ®Yes or®No Representative's Name: Date Contacted: Rep present during inspection? Yes . oro* Rep's Name: * If no, see notes on following page . . _ - III y Y Manufacturer Gem Valve Model Number F3061 Valve Serial Number HG-8-6#2018 Valve Size 3�� Controlling Number Sprinklers(approx.) n/a Date Last Trip Test 7/24/2013 Date Last Operated same Air Pressure Before Test 31 Water Pressure Before Test 84 Size&Location of Test Valve 1/2 at riser Was Gate Valve Below Dry Valve t10 3 turns Wide at Test? (If not, how many turns?) Air Pressure 31 PSI PSI PSI PSI Water Trip At: 10 PSI Water Pressure 84 PSI PSI PSI PSI Time n/a PSI PSI PSI PS' If System Flooded, List Time Water Reached n/aTest Openings • k - 11 11 y - it Enclosure YES 0 NO 0 YES 0 NO (:°)YES 0 NO OYES ONO Exterior YES 0 NO (3 YES 0 NO O YES NO Q+rES CD NO Interior .® YES 0 NO 0 YES 0 NO 0 YES 0 NO OYES fD NO Strainers, Filters, Orifices YES 0 NO 0 YES 0 NO OYES 0 NO OYES 4D NO Notes: Page 1 of 2