SHEET 1 OF 2. Use separate sheet for each building inspection REPORT OF INSPECTION
MINNESOTA LICENSE NO. COO75
JOB NUMBER
Owner's Section (to be answered by Owner or Occupant)
A. Explain any occupancy hazard changes since the previous inspection:
~
INSPECTION NAME
STREET
CITY & STATE
B. Describe fire protection modifications made since last inspection:
c. Describe any fires since last inspection:
When was the system piping last checked for stoppage, corrision of foreign material?
hen was the d~.,piping system last checked for proper pitch?
A dry va~~atelY ~cted frer freezing? .......;
Si ature . ~I Cl,.1 ~ . " Title
Date
,~
I P 0 s Section (All responses reference current inspection)
oeral
a. Is the building occupied? ~~ D No
b. Are all systems in service? es D No
c. Is there a minimum of 18 in. 457 mm) clearance between the top of the storage and the sprinkler deflectors? tjD'es 0 No
d. Does all electrical heat tape appear to be satisfactory? DYes D No lDNA
e. Does the hand hose or standpipe on the sprinkler system(s) appear to be satisfactory? DYes D No IJitNA
2. Control Valves (See Item 15,)
a. Are all sprinkler system control valves and all other valves in the appropriate open or closed position? ~Yes 0 No
b. Are all control valves in the open position locked. sealed or equipped with a tamper switch? ~es D No
3. Tanks, Pumps, Fire Department Connections
a. When was fire pump last tested for perfonnance? ~ /4--
b. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? DYes D No ~A
c. Are fire department connections in satisfactory condition, couplings free, caps in place"and check valves tight? 19Yes B No 0 NA
Are they accessible and visible? ~es D No D NA
4. Wet Systems
a. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position? DYes D No ~A
b. Have antifreeze system solutions been tested? DYes D No ~A
c. What temp is antifreeze? ---
d. In areas protected by wet system(s), does the building ~nV'~T tn be properly heated in all areas, including blind attics and perimeter areas
where accessible? tiiaYes D No 0 NA
5. Dry System (SeeltJr.; 11 to 13)
a. Are dry valve(s) in service? DYes D No 0 NA ,
b. Are the air pressures and priming water levels in accordance with the,manufacturer's instructions? DYes D No 0 NA . ..
c. Has the operation of the air nitr g n s pplies been tested? DYes D No 0 NA Are they in service? DYes D No D NA
d. Were low points drained du g t is ction? DYes D No D NA How many?
e. Did quick-opening devices I e ily? DYes D No D NA
f. Did the dry va\ve(s) trip p trip pressure test? DYes D No DNA
g. Did the heating equipme in e alue room(s) operate at time of inspection? DYes D No DNA
6. Special Systems (SeeJlem 14.)
a. Did the delu~pwactiotJJal~ s ate properly during testing? DYes D No JIg NA
b. Did the heat.responsive dev s r t pr rly during testing? DYes D No 0 NA
c. Did supervisory devices 0 r t esting? DYes 0 No 0 NA
d. Did flow for kitchen hood y ff gas or electric? DYes D No D NA
7. Alarms ~.
a. Did water motor(s) and gong(s) test sati\f.!.ctorily? DYes 0 No lLJ"f'IlA
b. Did electric alarm(s) test satisfactory? lSJYes 0 No 0 NA
C',Did supervisory alarm service test satisf~o,ry? hies D No 0 NA ~ 'Oct-
d. Did tamper swithces test satisfactory? JiYles b No 0 NA
8. Sprinklers. ... , .'
a: Are all s~inklers, free. from corrosion, loading or obstruction to spray diSCharge?:!. es D No
b. Are sprbiklers lesS than SO years old?,(Older sprinklers require sample testing) , es D No
c, Are.quick,response and residential sprinklers less than 20 years old? (Older spli lers require sample testing), ~ D 1'016
d.lsstockof spare sprinkle.rs available? ~es D'No , ., . .
e; Does the exterior, condition of sprinkle! system appear to be satisfactory?~es 0 No
f. Are sprinklers of pro perature rating for their.J.sl~ations? ~s DNo
g. Are any sprinkle ads a recall list? DYes ~o
4:
NA =NOT APPLICABLE
,
.~
d
"
,
,
I
i
,
:;
Signature:
Pscz
Date:
1//3/0'/
. /
, SUMMIT FIRE PROTECTION
. 7301 APOLLO COUR'P'LIllldt.AKES, MN 55014. (651) 251-1880
3026 40TH AVE. NW. ROCffl!SJlfl~.,MN.55901 . (507) 280-0622
418 GREAT OAK DR., WkitE'FMm; Mlilis6387 . (320) 257-6390
760 LIBERTY WAY, NORTH LIBERTY, IA 52317 . (319) 665-4330 .'1
SHEET 2 OF 2 - Use separate sheet for eachsystem inspection Type of System J)~ (I ~,.-
Inspes:.!ion Name and l"?'mber. How ManYl...: .....
!!.'f~ ~r$ w . e~~( ~
. . . $"1//0. i owSwi
.' . eck with Pressure Switch'
1:: ~:::~:~~:::::~:~ :::::~ i~::::: ::::: i::a~~:~n) . 4 L4-(Se:~';~:tT;;~/:8::c;~:;o:;~WS) .. .
11. Date quick-opening device tested (See Trip Te~: follows) .
DRY VALVE T BLE 0.0.0.
MAKE MODEL MAKE MODEL SERIAL NO.
t..
!
c!
DRY PIPE
OPERATING
TEST
Time to Trip
Thru Test Pipe
MIN. SEC.
Alarm Operated
Properly
YES NO
Water
Pressure
PSI
Arri~r:~~~
PSI
Time Water Reached
Test Outlet
MIN. SEC.
Without
Q,O.D,
With
a.O.D.
.-;:;;-.:_i' .' ~
12. Date deluge or preaction valve tested tJ I r
DELUGE &
PAEACTION
VALVES
(See Trip Test Table which follows)
TRIP TEST TABLE
Operation 0 PNEUMATIC D HYDRAULIC
Piping Supervised 0 YES D NO Detecting media supervised
Does valve operate from Ihe manual trip and/or remo ntrol stations
Is there an accessible facility in each Circuit fort mg Method attesting-circuits
DYES DNa
s o NO
DYES o NO
;'j;) ::"..
\ .i
~.
NO
r
Explain
Abnormal
Condition
MAKE
Does each circuit operate
su rv~ionlossalarm
NO
MODEL
13. See Control Valve Maint~naqce Table.
Control Valves
City Connection Control
Valve
Tank Control Valves
Pump Control Valves
Sectional Control Valves
System vOrllrol Valves
Other Control Valves
.~J~i~9he_!1_g0(l~roIVal,~e
16. Water Flow Test at Sprinkler Riser
Water Supply Source:
14. Explain any "No" ans~ comm,~ ,
~ t.11/1A. -t ~. /1'1
:.~~ ~,~~
......"/.>)
Last Water Flow Test
This Water Flow Test
Control Valve Maintenance Table
Number
Type
Open
Secured
Closed
Signs
Tank
Date
Size of
Test Pipe
Static
Pressure
Differential
...
<:)
~~'<'-A~-9~
~l> 4f Hr;tp::.$
HJ!:y(J;)<;: ("F" r,-.:.~ l
II./~ /:7 I
(, - /2't:IF,.wH.l , ::!
. - -~.-"t.J
",,",:;;::;) ;; ~ Pf e "" '~-r]
"hlot
Date: