Loading...
HomeMy WebLinkAboutSign Permit 15-22 Versatile Vehicles City of Prior Lake APPLICATION FOR SIGN PERMIT i Permit No. DIRECTIONS:One completed application per sign is required.Applicant is I. PARCEL T.D.OF PROPERTY: responsible for obtaining a building permit if necessary. -100 s 2. APPLICANT: (NAME) (ADDRESS) (PHONE) Schad Tracy Signs 1610 E Cliff Rd Burnsivlle 952-894-2421 X201 3. OWNER: (NAME) (ADDRESS) (PHONE) VERSATILE VEHICLES INC . 4, SITE ADDRESS OR LOCATION OF SIGN (PHONE) 16450 Anna Trail SE, Prior Lake, MN 55372 5. TYPE OF SIGN: TEMPORARY(21DAY MAXIMUMDISPL Q) PERNIANENT(YYALL/MARQUEEIAWNING/PREES7ANDI�YG) Balloon*Bttsittess*Cbrutgeable Copy Signs*Construction Signs*Electronic Message*Illundhated Signs*lnstitrdional Signs*Lake Service Signs* Multiple Residential Nameplate Signs*On-Premise Directional Signs*Permanent lKndow Sign*Portable Sign*Subdivislon Identification Signs G. SIGN DIMENSIONS 10. Estimated Value of Sign 41900 . 00 (square feet) (Height) (Width) (Depth) E, 46 . 5 50'r 11/2" 711 11. Completion Date 6/18/2015 1 7. TYPE OF CONSTRUCTION New Channel LED letters 8. PROPOSED DISPLAY DATES(if applicable) SIGN PERMITS WILL NOT BE PROCESSED IF THEY ARE INCOMPLETE I hereby certify that I have fiimished information on this application which is,to the best of my knowledge,true and correct. I also certify that I am the owner or authorized agent for the above-mentioned property,and that all constnuctiou will onform to all existing state and local laws and will proceed in accordance iwith submitted plans. I am aware-that the City Plannor can invoke this peunit f ust cause. Fmthenuore,I hereby agree that City Officials or a designee thereof may enter upon the property to perform neede specti 6/9/2015 SIGNATURE OF PR PEWrY OWNER/OWNER REP DATE I i PRINTED NAivIE O1V PROPERTY OWNER FOR ADMINISTRATIVE USE -- -- — SUBMISSION REQUIREMENTS ompfeted Application cafe Drawing showing location ofsign 1/ Plans and Specs ; { _Permit Fee$.7�, (Permit fee is set ? �, at time of application according to approved schedule) FUe� This Application(becomes yoonrSign Permit when approved. City Planner or desi ree A —' Date --- f This is to certify that the request in the above application and accompanying documents is in accordance with the City Sign Ordinance and may proceed as requested. This document,when signed by Ore City Planner or designee constitutes compliance with the Sign Ordinance. Special Conditions 24 HourNotice for All Inspections-447-9810 h%andoutAsign permit application.doc THIS DRAWING IS THE PROPERTY OF h - E schadrtracy Sign Type: ILLUMINATED CHANNEL LETTERS S�aq�llS, �- The Sign of Quality Voltage: 120 325 MINNESOTA AVE.N. i { Lighting: LED P.O.BOX 357 Raceway: YES- 7.5"H x 3"D PHONEDCO/507-367 2631 Installation: RACEWAY MOUNTED TO EFIS FAX/507-367-2633 ! 1 1610 E.CLIFF RD. - BURNSVILLE,MN 55337 i p PHONE/952-894-2421 A FACE: TRANSLUCENT RED PLD(#2283 FAX/952-894-2748 I f These Drawings Are ThIT Wusiw Property Of Schad Tracy - _ OVERLAY: 3M TRANSLUCENT VINLY FILM s+gnT They Represent diarg:aaenmespfm.They are #3630-00 w6mted(Or your your personal use undEr tha cgreamem that tha " use Of this design in its erltirEty or airy part will not he _ v - i reproduced,cop ad,Iant or u ad for Ory purpose without writt-M 7 t mra-ehamSchad TmEySigns. B.TRIM CAP: L BLACK cilBm: ----: r� Now 1 VERSATILE VEHICLES y ; C LED: DS 8 SS-RED PRIOR LAKE,MN D,RETURNS: BLACK E RACEWAY: PAINTED TO MATCH BUIUDNG Date: June 04 2015 Ii. 1 IIMPORTED ' Drawing Number: ! RB8801-06-04-15 Revisions: j _ DATE: DESCRIPTION: I I B 00-00 NA 00-00 NA 00-00 NA ii A D 00-00 NA 4 ! 00-00 NA E I PROPOSED-SIDE ELEVATION-CHANNEL LETTERS I f. � 3116"=1'-0" -00 NA Sales Person: I RICK B. Scale: 50" C 3/8"=1'-O„ Ij Drawn by: [ Darren D. TYPICAL R --- - - -- I! CLIENT/LDLORD APPROVAL CHANNEL LETTER SECTION DETAIL ❑APPROVED -I CHANNEL LETTER ❑APPROVED AS NOTED ❑REVISE AND RESUBMIT 0 C Amru U TRIM CAP— MOUNTING HARDWARE Signature: AN 16" L.E.D.UNRS i, 501 LM 7.5"x3"RACEWAY Title: I` WIRE CONNECTOR PAINTED TO MATCH 10GHATU'RE MOVE ACKNOWLEDGES THAT ALL MOUNTING SURFACE TUHIS AND ACRYLIC FACE DIMENSIONS ON THESURAWRiGS AR UNDERSTDODANDCORRECL CONNECTOR PENETRATIONS SEALED WITH SILICONE POWER SUPPLY THIS ISAN ORIGINAL DRAWING PROVIDED AS PART I GROMMET (-120 VOLT SERVICE OF PLANNED PROJECT AND IS HOT TO BE EXHIBITED 1 COPIED OR REPRODUCED WITHOUT THE WRITTEN r l .090 ALUMINUM RETURN LOW VOLTAGE WIRE E PERMISSION OF SCHAD TRACYSIGNS OR IT'S E' I .050 ALUMINUM FLACK AUTHORIZED AGENTS.ALL RIOGHTS RESERVED. I' f I' 6'-10" I PRIMARY ELECTRICAL POWER TO SIGN j I URGENT-ATTN:ELECTRICIANS CIRCUITS REUUIREO TO BE BY OTHERS. ALL POWER TO BE tl NEW ULZIGI G.F.P.SIGN TRANSFORMER ONE(1)20 AMP. i i REGUIRETHAT ALL CIRCUITS MUSTHIWE 1 120 VOLT 120 VOLT UNLESS OTHERWISE STATED. ® DEDICATED NOT,NEUTRAL GROUND ELECTRICAL TO USE I TERMINATING ATPAHEL CIRCUIT DEDICATED 0.L.LISTED COMPONENTS REQUIRED DutsnONs:rALLIS-caRP.Iaoaaeoaue TO SIGN ONLY �` AND SHALL MEET ALL II 11'-2" N.E.C.STANDARDS I, SIGN MUST BE GROUNDED IN COMPLIANCE WITH I - 'i MPLIANCE WITH ARTICLE 600 OF THE NATIONAL ELECTRIC CODE. ARTICLE 600 OF THE NATIONAL SIGN MUST BE GROUNDED IN ELETRIC CODE. I _ — SHEET NO. 102