Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit 15. 1145 Maintenance Fac.
g 0 C) O 0000 -a o > ■ 0 $ n n 0 ■ II 1 0 § v PO 4 § O 2 22 m >c� 2§ m xi m §o % 0 m m . m E E'coz g 0 � 13 Z 71 ® § o P �% q k k Kb Z z § g gk 7 § / 0 O k \ n > 0 m , • 01 0 F. z 3 F § il o 13 '0 ' i x ■ 0 0 .efL 000000 m � mm s -o ■ s -D § -4 § 0 0 ^ .� m � 2 > 0C �� _ ■ m ■ ■ -0 n N_ CO % i \ �� �� EEXX - E M k k q - g § ` ou r r f §/ 2 / § Z 71 M 1- -0 / 0 k 0 M PP ■ o ce ❑ OQO Q 7 . � > , o § — § Rs o Q ■ mm ■ Q m < E � � � � 47 z m00 § A t - r— 2 u) z m -Ir 0 F PRtp CITY OF PRIOR LAKE BUILDING PERMIT, Date Rec'd is y TEMPORARY CERTIFICATE OF ZONING COMPLIANCE 7 (7 6 tri AND UTILITY CONNECTION PERMIT • 44,„,Eso;s>" i. White File 2. Pink City PERMIT NO. �✓ i t i Yellow Applicant / (Please type or print and sign at bottom) ADDRESS ZONING(office use) 17073 ADELMANN STREET SOUTHEAST LEGAL DESCRIPTION(office use only) LOT BLOCK ADDITION PID OWNER (Name) CITY OF PRIOR LAKE (Phone) (Address) BUILDER (Company Name) METRO ALARM & LOCK (Phone) 952-890-6684 (Contact Name) TOM BONWELL (Phone) 612-685-3734 (Address) 3921 W. 143RD STREET • SAVAGE, MN 55378 TYPE OF WORK ❑New Construction ❑Deck ❑Porch ❑Re-Roofing ❑Re•Siding ❑Lower Level Finish ❑Fireplace ❑Addition [Alteration ❑Utility Connection ii; CODE: ❑LR.C. ❑LB.C. ®Misc. REPLACE BROKEN FIRE PANEL Type of Construction: I II III IV V A B ccupancy Group: ABE F HI MR SU PROJECT COST/VALUE $ _T & M ivision: 1 2 3 4 5 (excluding land) I hereby certify that 1 have furnish-•• rmation on this application ich is to the best of my knowledge true and correct. I also certify that 1 am the owner is authorized agent for the above-mentioned property and HJT construct•- ill conform t,.all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building offici.l can r •this per t use. ore,I here.,agree that the city official or a designee may enter upon the property to perform needed inspections. x ° TS000401 9-17-15 Signature Contractor's License No. Date Permit Valuation Park Support Fee # $ Permit Fee $ SAC # $ Plan Check Fee $ Water Meter Size 5/8"; 1"; $ State Surcharge $ Pressure Reducer $ Penalty $ Sewer/Water Connection Fee # $ Plumbing Permit Fee $ Water Tower Fee # $ Mechanical Permit Fee $ Builder's Deposit $ Sewer&Water Permit Fee $ Other $ Gas Fireplace Permit Fee $ TOTAL DUE ND e $ This plic 'o B- . es Your Building Permit When Approved Paid Receipt NO. 1 Dat t By Q 26//5 t ` , Buildin_i()Ili //Date This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and may proceed as requested. This document iilhen signed by the City Planner constitutes a temporary Certificate of Zoning compliance and allows construction to commence. Before occupancy,a Certificate of Occupancy must be tied. Planning Director Date Special Conditions,if any 24 hour notice for all inspections(952)447-9850 4646 Dakota Street Prior Lake,MN 55372 • Proerred MatrMetrop1çLock a Lott Saving Lives E Protecting Property Since 1274 www.metroalarmco.corn 3921 W. 143rd Street Savage, MN 55378 Phone: 952-890-6684 Fax: 952-374-6182 Equipment Submittal for: 4 -be � .ia - l .§ $kb Cst rl „fi to � i 52 ,0 ;,::„;.,:;,-,:7.-,-.-:,•-;.,::..:„.,:;:,-;:i. r Prepared by: -'!"- i •77 d ,,,PI ,. ,.,,,i„.. ,.-.),E.vEv....._ KE r ! :E • Thomas R Bonwell ejzil __- --PERNCT NO. - -.E; SUBMITTED Engineer ,TED WITH CORRECTIONS AS NOTED Nicet#111574 L; NOT ACCEPTED-CORRECT& RESUBMIT PLT#PL00832 I,-,.;, comments are for your information.AU work shall be done mance with ali applicable building&zoning code nq items not specifically noted in this review. '..7,E7 ,T,I\,! SITE AT ALL TIMES Date: 17-Sept-15 ,(MO UL Listed Alarm Service Company # S8526-1 • MetroAlarm"yak'" Lock • Lee Saving Lives E Protecting Property Since 1970 www.metroalarmco.corn 17-Sept-15 Prior Lake Maintenance Facility 17073 Adelmann St. SE Prior Lake, MN 55372 REPLACEMENT OF FIRE PANEL PROPOSED WORK TO BE DONE 1- Replace the old SK-5027fire panel with a new SK-5208 fire control panel and install per NFPA 72 2010 Edition. 2- Replace the old SK-5230 remote annunciator with a new SK-5235 remote annunciator. 3- Reconnect waterflow switch, gate valve tamper switch, two duct detectors, five • strobes and twelve horn / strobes to the new fire panel. 4- The above install will be made with the following deviations: a) Annual fire inspection per MN Rule 907.20.2 b) Manual fire alarm box not installed per NFPA 72 23.8.5.1.2 c) Smoke detector not installed per MN Rule 907.1.3 THE ABOVE WORK IS SUBJECT TO APPROVAL BY THE LOCAL AHJ PROPOSED BY: METRO ALARM 3921 W. 143rd Street Savage, MN 55378 Contact-Tom Bonwell Ofc. 952-374-6173 Cell 612-685-3734 Email: tom@metroalarmco.com • M FaT l!' ® ALARM k_ LOCK • 3921 W. 143rd Street Savage, MN 55378 Phone: 952-890-6684 Fax: 952-374-6182 Prior Lake Maintenance Facility Quantity: Description: Model#: 1 ea. Fire Control/Communicator Panel SK-5208 1 ea. Remote Annunciator SK-5235 • • FIRE ALARM CONTROL PANEL SILENT Model 5208 • itik KNIGHT Fire Alarm Control Panel ® with Digital Communicator by Honeywell The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO®, Class A(Style D)or Class B (Style Gentex®, Faraday, System Sensor®, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel • Clock source setting options for 50 - • Event History Buffer(150 events) Hz, 60 Hz,or internal (uses the • with date/time stamp panel's internal clock) • All zones are compatible with 2-or Specifications 4-wire detectors , • 8 selectable/programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: V relays Height: 24.75" (62.9 cm) • Programmable smoke verification, Width: 14.5" (36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8" protruding that can help minimize false alarms Overall Dimensions: SK-5208 • Programmable from the built-in Height: 26-3/8" (67 cm) control panel touchpad, remote Width: 17-3/16"(43.66 cm) • SKSS Downloading Software annunciator, or Windows®SKSS Total Depth: 4"(10.16 cm) • Plex-2 Door Option downloading software Operating Temp: 32°to 120° F Listings and Approvals • Direct connect port for on-site (0°to 49° C) • UL Listed up/downloading with Windows® Humidity: 10-93% noncondensing . CSFM Listed SKSS downloading software • Built-in walk test feature Optional Accessories • MEA approval 429-92-E Vol.XIII • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability • SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) III while providing single button • 7181 Fire Zone Converter operation • of the reset and silence • 5220 Direct Connect Module functions 5824 Serial/Parallel Printer Interface • Programmable AC trouble relay Module FIRE ALARM CONTROL PANEL Model 5208 • Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect _ - For On-Site Programming 2 Class A(Style D) —. -T a �' �lr • • or Class B (Style �� B -' * Programmable Initiation Circuits d .„ Il .. _. Form C Relays j p l MI 8 Class B (Style B)4._ ;f^ 3 6 . ► ;l . M, Notification Initiation Circuits = #_ . o : ,l . :, Appliance Circuits .--.. ENM ■ 5235 Remote I I ou "-� ,®� ;Annunciators hf...„1 "-�' SBUS Devices :0 5280, 5217, & 5824 To AC i This document is not intended to be used for installation purposes.We try MADE IN AMERICA SILENT to keep our product information up-to-date and accurate.We cannot cover • KNIGHT all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent ©2010 Honeywell International Inc. by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610(203) Phone:(800)328-0103, Fax: (203)484-7118. www.silentknight.com FORM#350318 Rev C REMOTE ANNUNCIATOR IIISILENT SK-5235 it, KNIGHT Remote Annunciator by Honeywell Program and Operate the SK-5208 FACP from a Distance with the SK-5235 Remote Annunciator. The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK-5208 can support up to six 5235 Remote Annunciators. Call Silent Knight today for more information 1-800-328-0103. Operation When the system is normal and FIRE ALARM ANNUNCIATOR receiving AC power, the power ALARM TROUBLE LED is on and all other LEDs are SUPERVISORY SILENCED off. Other LEDs turn on as the AC conditions occur. MODEL ECU IP Users identify themselves to the . control panel by entering a code 1 2 3 A on the annunciator. When a user 0 presses a button, the annunciator 1 piezo beeps and the LCD prompts SIUNCE 7 8 9 the user to enter a code or other 0 relevant information. .- --., --..,,... Features SK-5235 Remote Annunciator • 2-line 16-character LCD display • Indicates Trouble,Alarm, Supervisory, and System Status Specifications Ordering Information conditions with LEDs and LCD Operating Voltage: 24 VDC SK5235 display Current Draw: Remote Annunciator • Each SK-5235 is individually Standby: 30 mA supervised by the SK-5208 Alarm: 50 mA FACP Dimensions: Compatible Products " • Up to 6 per SK-5208 FACP Width: 7-3/16SK5208 (18.26 cm) • Operation and appearance Height: 5" Fire Alarm Control Panel comparable to the control (12.7 cm ) panel's on-board annunciator Depth: 1-1/8" • Can be wired up to 1500 ft from (2.86 cm) FACP Operating Temp: 32°to 120° F • OPR operator's key ships with (0°to 49° C) SK-5235, this key can be used Maximum Wiring to perform user operations, but Distance: 1500ft will not open the control panel door Approvals • MEA 429-92-E • • CSFM 7165-0559:137 • UL Listed REMOTE ANNUNCIATOR SK-5235 4I1) Remote Annunciator Engineering Specifications The contractor shall furnish and install where indicated on the plans, the Model SK-5235 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote programming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP. The control shall be capable of supporting up to 6 supervised SK-5235. Module shall be designed to mount on a dual gang electrical box with 18 gauge to 14 gauge wire. Ed I.=_ i I n r r DIC O /� / ,ART. 4 / u Wk`' O `OA'.. A. SIi12 E i3' c u' 11 ,z) 0 SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA 4r., KNIGHT keep 00000daaeWn specificur applicationsprductinforrmatianticipatenup-tall- requirements.et eq Allt .specieficancationsot are allCI FORM#350321 Rev C by Honeywell subject to change without notice. For more information,contact Silent KnightIII ©2010 Honeywell International Inc. 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax: (203)484-7118. www.silentknight.com