Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit 07.0759,08.0443,08.0009,07.0822,07.0900,07.1186
A t� ��/��j4 A\� ;:7 � l ��i v y � ��,❑f ��'' J{ �, `lu._r rr_.r..ir_:n,. _: ,i_.i.. .: ..� _. .,r.. _.i �_. .,li. _, _.ii.. ,._iYl .a __i ,li ,_. ii��i� li., YI:, ,. .ii�.,YV�,ir_. _.nl,i _.ii..i . .. . .. ,f CfCrrhf rafr of ( rtup ntt r "`� CITY OF PRIOR LAKE ��'� K....,_:, prparfnuttf of '-p.-'1 u i I t it i I t c3nsiartfiett :-.: X Final Permitted ❑ Conditional C.O. Expires ,, ; This Certificate issued pursuant to the requirements of Section 110 of the ❑ Residential/❑International Building Code certifying that at the time of issuance this structure was in compliance with the various r ordinances of the City of Prior Lake regulating building construction or use. For the following: �c� = Use Classification P�;;t`@. a i W1. Z Bldg.Permit No._ Q ) " 7✓ Occupancy Type g 1 Type Construction Zoning District _ Legal Description L � e �C1Y\� S/ ti Owner of Building Site Address ,,Y)?OCQ 3 I��r PL. ,..-_ Contractor's Name&Address loer - 6(&CclA1 l A City Planner = Building Oficial ' "t Date: /L( /11 Date: POST IN CONSPICUOUS PLACE q q i i ' V i i i 1 I IITH 1!;," ' A'''.V,',!,,1 _Wti Jif I ' 7p1j i s i Vi 1 "1 n I ❑\ if d 0 3....a N � ,P o � u F LL Ly Zoo z � aG 41 t Luou. u. a a�7�, O ULLLL (9 >0 co co ❑ ❑ ❑ D ❑ ❑ CV a,' `S U O c.ip , 0 _ �to j 1 I. � :. .�1 0 N O LU• ' O > a.>Z se se z O O a O �‘ (, 6t O U U Z. -J G • re —• F- x 00 (� ar. y 0 w N O W• !► Z - Z _ xxzz -.Y' a Z 3 N v aD3 IL' re= wxgx wwz eXWzLA_j w _ J w rii a2 u) o. 2 xxyyC LU C7'3z a p w �/ O a U YV— zz . '►' o • m :11111111111\! a Z WoOC t n tz ZVt/ oMZ ° f= I a 0 � Z a ~ - O zz1Zg w YW a W _iz o a o w26 NV (.50w 4 0a I z001Z20 QU U 0 * Ua 0 a 0000 0 J Wz _ 1W Z - = WWQ il gWV Rl -.5-- o � � N W �� i,❑ D ❑ ❑ ❑ ❑ > N rz 8 o S 0 x I O N o w ` a aa � m z q C t 2 ppYptiJ e p U V 4 W O OOOQ Slib '/ v y Wa j X Z a' Z � = x =ti W N 0 a � xw � � x 'k" N 0 __ p 0 I" O V cn p p z ►- p Jacm � 3Na w w W w V` ❑ ❑ ❑ DD O O re Z aC a a LL I V I z gy g � OQ < oao icg OZ p z 0 Cl) H n Qi Oz qO a Q f- 1- oWC ua. 0 co Z H- Z2 -I 1JJ Y tx Z G Q A V W - W p Q W im re K O OW Ce W Z OO1eNZI- 2 O O O V V ra p 0 au. � ? u.u� Z o o 1' 0z < 0 a 000000 C.) 0 0 c C5 zkIii P - ■ U- ■ 2 E - eww - K r 2k5\ 11 * § z 2 0 � k�§ k e ■ « 0 8 � IL61 2 z © I 00000Eo o R w z ) § N § w k 2 § z Z zK as 0 i � � 0 0 c2 I- e o o —J 0 0 0 - © co o K � i z & 2 2222 . 0 / z 0 w ■ ■ coco a S s 0 a % § � § § § '�, w w a] § 2 0 -4 ■ « � W . 2 a ■ � as � ❑ ❑ ecoO ' ® hilik O. a. § k re 0 k 0 I ktu w 00 k \ Z « ■ o b 0 0 2 k 2 0 zo § I- - a % 2 § z 2225 z L 2 w w b j % u. p $ � 2 �ja � 0 0 0 0 Q U w W 00 d(4) Zr- 0U / Pa re 0 - 0 uu$ § � § E. O ^O c Q § « 0 a 000000 U 0 J F- Z ZEN) W I- :"I LL Z GWL, ~ LL Z 0 V Q > k. ,,1 2555 = c, °a [1�' Id 0"2 W W N Z-a, Z E. W 1 W o U- 5 a W y o "' r W V is: LL (9 ) N 0 000000 o 0 oWC = 0 N C 0J m o 0 W O Q z U RL J Z YYLL J - a�0 c d aj c W Z W Z - xxz ? 6 W z Z Q U : O W CL � � � mLL 0 0 LI) X O co %. V d jVFW ?V 1� W W W W fi. JWQ JW ``►1US UI it a � 3v� a � O O W 0000 ❑ ❑ a a � � :40. QZ W ` Q ZO cn OC O N O Z z W F— Q U U oC Z v O N W � p O Z0 -0 Z W W CC ° Q C CO z 5J - 0 0 0 �, La LU 0 M < Ili3 U U m uu)i o - o LLou. Z N 2 ❑ ❑ o Q 0 a 00001k0 V O tv Z Zin \ ❑ u ! . a d U N 55 W to 5=XOaV� � Q l 000000 -w - ZW> IQ a 'd tz Nc ,` _ It • O N C Z 0 amJ U 3 z U v gam p Q i 0 J \ Z 0 0-J v / �rj 17. c a j O �- �Z ix O 00ix ZZ i FJ a Z �� V ; 0 d sxWx2x . �, w w W W 04 W W Z ftp nJ. �3v)1JaWTe V v re w .CC ❑ ❑ ❑ ❑X❑ nx. xa H t2 Ir. ..1 40) CC ZZ Q 0 W O Q 0 a O , a ~ W YV p � p y_ gp Z z U N V I Q V V W oZ ° CD° N Z G 1 x o '- o a o u�p N O Zoz Z W IX x 0 v aUj N Z laz !� < w 1 _ ; Q0 c0� OW 1 rw Z 00 2f•h � AO- „'� y dB c IN 0 0 LLtL tL = u. v1 0 ❑ ❑ c) 2e a 0 a ❑❑ ❑ ❑ ❑ ❑ CD • „; r o J w z ya _ F. aWlZCi1a k. ca WZpr O 2 W LU u) — Z UWao 4 i9 y ( z0000 ❑ R w> ykj • I 0 0W O D cc x U O N J \ IL J Z »Z X11 m w Z O�j O YY _ c O_ QC r2 L—. 2 0 p 0 �' 4 _ Op Q V 0 0 LU Z � OZa i 17: as la V a 0 ° m � � m I 1...../, Dt=i ►W- m � a z N y 0 a � 3ya � w w W w w n1 000000 , o 0 z Z >: 0 J YW (1 0 Q Q reO 41 p 0- --J I% C~1 O ,4„, N ccyy re O f. a oC OZ O Z W Imo— N V ���, tsa� aLU LU ga4 U. � y Z ZC ? O Z W I aai 0 �4 CO y0 C e I g Z 0 Og t 2 LL W LL = U. co O ...r. 1 1G_ 3 0 0 U V 5z a 0 a 000000 C) 1-• —1V-- A .1 W Z = FN- LL! Z U V a Z gg55V ,I > vi aaa � a 4S (7 � WWN j Z-a, Z cW wpaaQ W N a i ULLLLC9 �' w ' 000000 T U =O �yy W = J m Z O si J Z Y Y Z z U V " 9 .-- d F- E OOLLJ o a� d c = Z Z � = = ZLL v aW, 6 Z ^ 3 N V d j0W ? V �, W w Z I- oyy WLU W 4C 1 a23v� a2 U U = d d LL I- ' ~ } Z _I cc W 0 Q U OLL oC • WLLJ W I- p Y Y ! Z Q °D �' ' iCii 5U O LL 0 .� os ~ Z 0 ,-r- �' a w Oz 0 p d CI Z N W /J W ap N O zoz ~ Z W _ W la o a C LL. N Z � zf� aw 2 o 0 0 O}W Z W Z 00 W4 X /- 2 • 0its U In U ? Q 0 a 000000 0 U' JE.. W Z II Cr W D. a0 .ocereay rtW Zc 0000 0 . > co o o w _ o N c, c,w Z vj 0 aa - Q m O 0 wYzZ 0 - - J 0 0 w F- M 0 00 < • c 0- U 0 w Z x ZLL 0 U) O m xxm a 3 Z co U a 2xwgx O 4 J W Q J W 0 0 Z X a0 a2 .....cc cna2 w w W w 000000 0 0 0 CC z• I'� a a a 1 H z 0 ww 0 < 0 0 ix go Z a gaG co � Z 0 z U vi co Q 3 .: a d � N Z Z � ? QJz z Y w '� ,,. w OW U W W W 0 D r. 4r DD a W r4 �Q c }} uj ce o. QQ 00U F_ cn C 0 OOLLZLLN 0 0 0 o. U U ? Q 0 a 000000 C, \❑ 0 E. Z ili _ aco ~ ccu. re Z W ~ ZUVa Q w 2555 = c O Oa. W WN z ? [. O 1 `ib V 000000 \ o O tY set z 0 c O o LU O aaQ u Z 0 0 'R,.., D ..iJ re. H a OOLL -i '' 1 r- d a t o W ° OZ = �- w 8 N 4 U 0 w mxwctmx o o z o N U DUF. DU JWQ .,,i LU W W a. W LI, a23waX `` v0 0 Z oG 0000 ❑ ❑ U ``� a a 0 IL t=- > Z J W v. V O = V o 4y W W1\1 z\ \ a 0.__ 6 , „� U 5F- 0 �> N a 3 a wz 0 w H a < ~ t- °� O z w w J iu iu a� N Z 1z2S _1Z 2 t rt o w 0CNWOY Z OOZZ - . ( U U a 0 O . . 0 i O Q = ❑ 8/ 0 cVZ 0 a 0000 ❑ C nEdr.',. ,1 &rfifir tfr of ®xrtpattrjr CITY OF PRIOR LAKE prilarftrittlf .of NuUU.MMrtj jittsprrfion El Final Permitted ® Conditional C.O. Expires �'r1 , (: )1)o)S 1 This Certificate issued pursuant to the requirements of Section 110 of the ❑Residential I❑International Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City of Prior Lake regulating building construction or use. For the following: Use Classification 4_ F { f_ --' 1 "?c r Bldg.Permit No. ' / — 0 t ) i ~.. Occupancy Type 1 Type Construction Zoning District Legal Description L ( , C" ) '_ lit.-) \ - _t c1 4\A A 1, 1 f. Owner of Building ) i• / (( ,` ' ) Site Address • {f e v).e".t i0 l r t eo (-{) Contractor's Name&Address i �i, i City Planner / l Building Official , Date: t„,„./ LL r^/ (/ Date: POST IN CONSPICUOUS PLACE V V'. (cr PR/pd C CITY OF PRIOR LAKE BUILDING PERMIT, Date ec'd TEMPORARY CERTIFICATE OF ZONING COMPLIANCE . U x AND UTILITY CONNECTION PERMIT 0. v 0 1 "iHNESoI° I. White Pink City PERMIT NO. Yellow Applicant Oy-01 51 (Please type or print and sign at bottom) ADDRESS ZONING(office use) 370 Ca —T0..4) ?L ACE -c.. ,.J. ?Q' c 1. 4 to ,a,v 5337 z. Pc-) S \T) LEGAL DESCRIPTION(office use only) /� LOT 1 BLOCK ADDITION J6(----f-±-10-5 RU ii/Lj.) Ao0 rJ PID 2 S-. to3-' 3/ -O OWNER (Name) CzT y OF ?Z-=-e,e- L,4-r r (Phone) 952"`/4/7 _ 9 ezco (Address) 16'/6.. ?A-k.c--r.4 S-re € g•a. 2's `p L4-1c-Ii- ee->A-/ S-S 3-7'Z BUILDER (Company Name) n1 ET- C,0) LOA)`."i'Z.O 0`T=G' ' (Phone) S 7 ' 3 3 Z- 2 2-C., G, (Contact Name) -2.'ca-`C.e- `may s c.v y (Phone) 567- 3 3 3' // `1 (Address) I S7 G.o (4-e�o,�..v _ ,4 _ p-,4-4.m.t ,.- i=7- ,g-t-✓ s 5 o- 1 TYPE OF WORK ®New Construction ❑Deck ❑Porch ORe-Roofing ❑Re-Siding [Lower Level Finish 0 Fireplace �f�❑Addition ['Alteration ['Utility Connection 0 Misc. CODE: ❑I.R.C. [!JLB.C. PROJECT COST/VALUE $ 1,908, 7 00 Type of Construction: I La Ili IV V A (excluding land) Occupancy Group: A 9 E H I M. U Division: 1 3 4 5 I hereby certify that I have furnished information on this application which is to the best of my knowledge true and correct. I also certify that I am the owner or authonzed agent for the above-mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building official can revoke t - permit for just cause. Furthermore,I hereby agree that the city official or a designee may enter upon the property to perform needed inspections. X Z 2C::, eV- 7 Signature Contractor's License No. Date Permit Valuation 107Af00., Park Support Fee # $ N / Permit Fee $ 77 SAC `i 7 # 4 (p 7 QO, - Plan Check Fee $ Water Meter Size 5/8";1"; $ State Surcharge 5-04',*9Dt�) $ /603,60 Pressure Reducer $ Penalty 'fid'' $ Sewer/Water Connection Feel,, # 4 $ 6o - Plumbing Permit Fee $..S11991-ATE RE-Q Water Tower Fee /000 # 4 $ .1(0 Mechanical Permit Fee $ cJ !E Qom. Builder's Deposit $ Sewer&Water Permit Fee $ 06_724:92.RTU 4-ID, Other $ Gas Fireplace Permit Fee $ TOTAL DUE $ 17 6-403,60 g91oo 6 Cfry This Application Becomes Your Building Permit When Approved Paid /71-6,3i.(o,c� Receipt No. s4 5-.3/ I - n, ' Date a 7 By /� 0,-A41-t-; G� g//3�d 7 Building Official ate This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and may proceed as requested. This document when signed by the City Planner constitutes a temporary Certificate of Zoning compliance and allows construction to commence. Before occupancy,a Certificate of Occupancy must be issued a.. teu....,-,i, tr Planning Director Date Special Conditions,if any 24 hour notice for all inspections(952)447-9850,fax(952)4474245 16200 Eagle Creek Avenue Prior Lake,MN 55372 ‘03.V ii N'u� CITY OF PRIOR LAKE BUILDING PERMIT, Date Rec'd I� , TEMPORARY CERTIFICATE OF ZONING COMPLIANCE � `� AND UTILITY CONNECTION PERMIT `IsrNN EN s2 k4,,‘Ai• 1. 1 Q ./go' i.white File PERMIT N ,/ l 2. Pink City 0 8. 0443 3.Yellow Applicant -] (Please type or print and sign at bottom) ADDRESS ZONING(office use) 376(a 54,1(6, p/,,,,_ Ai W /124ar tch./e LEGAL DESCRIPTION(office use only) LOT BLOCK ADDITION PID OWNER // 9 (Name) /-(u✓" Gt.� -� A--:---,e 04/7'- (Phone) (Address) BUILDER /�/ 62ri (Company Name) *f/ S v U ;-2-x.----. (Phone) (Contact Name) (Phone) (Address) TYPE OF WORK ❑New Construction ['Deck ['Porch ['Re-Roofing ['Re-Siding ['Lower Level Finish 0 Fireplace ['Addition ['Alteration ['Utility Connection CODE: ❑I.R.C. ❑I.B.C. Misc: A-7/4e ,i/:: �11?" . Type of Construction: I II III IV V A B( Occupancy Group: A B E F H I M R S U PROJECT COST/VALUE $ 026- Op Division: 1 2 3 4 5 (excluding land) I hereby certify that I have furnished information on this application which is to the best of my knowledge true and correct. I also certify that I am the owner or authorized agent for the above-mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building official revoke this pe 't for jus . Furthermore,I hereby agree that the city official or a designee may enter upon the property to perform needed inspections. X 6<0 if 7,5C2Z a Signature Contractor's License No. Date Permit Valuation Park Support Fee # $ Permit Fee $ /�.2Q d? SAC # $ Plan Check Fee $ l Water Meter Size 5/8";1"; $ State Surcharge $ Pressure Reducer $ Penalty $ Sewer/Water Connection Fee # $ Plumbing Permit Fee $ Water Tower Fee # $ Mechanical Permit Fee $ Builder's Deposit $ Sewer&Water Permit Fee $ Other $ Gas Fireplace Permit Fee $ TOTAL DUE $/2,1 '_ / q This Application Becomes Your Building Permit When Paid /12, . 41 R ipt No. x.30 2. Approved Date 7, '! 08 12/05/2007 13:51 FAX 507 334 8790 BAUERNFEIND GOEDTEL Z 002 �oF 2R/0 CITY OF PRIOR LAKE Date Recd -441 HEATING/AIR CONDITIONING/FIREPLACE PERMIT _ �L/5.. a,.,�7/ 4YfN1VEso ft ik W j 0 -� oil t. Cr F':: lPERMIT NO.Oa 0009 z,F City 3. Vellow* .AppI L11 i�Plcacc type ox print and sign at bottom) ADDRESS F?✓"'6,.. 4A kf' p...6 14'r.4-4', Ili 2 ZONING(office usc) LEGAL DESCRIPTION(office use only) LOT BLOCK ADDITION PID OWNER53Z-�lY7 - 9 00 A (Name) OWNER ,, of Py,'„,,.. 44 P (Phone) (Address) I/ yG De ' ,*. sit-,,,w-/- s E APPLICANTmelf Geed-1-e (Phone)�a Kt Ai rd,. � So 7-33y- 7`/'.r/ (Address) /5760 „41 day., /w""/ 5ki'•'C ''tZ ---.n-„ 'd.n.Li. /'i S,70 Z / (Address. (City) (Zip Code) (Contact Person) eteaAlef�/,,I ' 1L (Phone) SO7-33�-? ' / APPLICANT SIGNATURE /' e/ '�"'"” ,-.,.—r T.v DATE I2/4-//e)7 _ _ APPLICANT PLEASE COMPLETE BELOW ja EW CONSTRUCTION ❑REPLACEMENT ❑ ALTERATIONS FURNACE MAKE AND MODEL FUEL F L U E SIZE RETURN OPENINGS INPUT OUTPUT TYPE OF SYSTEM HEATING OR POWER PLANT PLEASE NOTE: Mr Conditioner ❑Warm Air Plants ❑Steam Units and Fireplaces Cannot Encroach ❑Gravity ❑Hot Water into Required Side Yard Setbacks. 2 Mechanical ❑Radiation Fireplaces with Box Additions or ®Air Conditioning 0 Special Devices Cantilevers to the Outside of Buildings . 4'cnl.System 0 Other Devices Require a Building Permit Fl REPLACE MAKE AND MODEL FEE SCHEDULE Industrial,Commercial&Multi-Family 1%ofjob cost Residential,Gas Fireplace $39.50 $39.50 minimum Rcsidcntial,Healing&A/C(Ncw Construction) $99.50 Residential,Additions&Alterations $39.50 Residantial,Heating Only(New Construction) $64.50 Rcsidcntial,AC Only £39.50 uo Estimated Cost 5 13 I) 7b0 Building Permit # BEATING PERMIT FEE S /, 3/7 tl e 0)/(it O 2STATE SURCHARGE S .50 ' 01/ TOTAL PERMIT FEE $ iJ 3 I 7 -° (Office Use Only) This kpplication Becomes Your Building Permit When Approved i Paid 13 17. S0 Receipt No.SS-/S`/ f � ¢ 2:�; iz //i d Date is By Bulldine Official Dat¢ 1/31 24 hour notice for till inspections(952)447-9850,fax(952)417-4245 4646 Dakota Street S.E.,Prior Lake,Minnesota 55372 o� rRi°� ► CITY OF PRIOR Sx C LAKE SEWER AND WATER PERMIT Date Rec'd re V Z` (or7 �'/NNEs��'� ��ciE A✓ o7. o749 Gran File PERMIT NO. -7 /� 3. Gold App O/.OYIZZ 3. Gold Applicant V (Please type or print and sign at bottom) ADDRESS r)t Uk ZONING(office use) 3 'o ( 544-.... to/ 4' ) ( ` t'--V LEGAL DESCRIPTION(office use only) LOT BLOCK ADDITION PID j,$ ¢fe3. 039.0 OWNER 7, 7 4i, ODOrc o r Gc'e (Phone) (Name) (Address) (Address) (City) (Zip Code) APPLICANT ere /� / /� C : � --5;?-(7' (Name) feC l� G (c., a . (Phone) rW" (Address) (75.5-e- 271 K SY� c £/k0 P/v rs-0,-0 � '(Address) (City) (Zip Code) (Contact Person) JGc S 3;c c L.S (Phone) 41C-77-f— F2 APPLICANT SIGNATURE 'ifDATE ♦ , D APPLICANT PLEASE COMPLETE BELOW Size of water service inches. Location of any couplings from structure feet. Type of sewer pipe. 0 ABC 0 PVC 0 Cast Iron Estimated length of sewer line feet. Clean out(if required) located at feet from structure. FEE SCI�T.D3I] Residential sewer and water line connection $35.50 Industrial,Com'1&Multi-famil 1%of job cost with a$39.50 minimum Sewer connection only $17.501Water connection only $17.50 Estimated Cost $ �X Building Permit# SEWER AND WATER PERMIT FEE $ a SD. on '°1pe STATE SURCHARGE $ .50 . TOTAL PERMIT FEE $ 2.50 . Se) / (Office Use Only) This Application Becomes Your Building Permit When Approved Paid Zso. ,5-0 Receipt No. -- 36 g i t:7(a 7 Date 0/ By i!�C�i6., ding Official/e*/1Je i Date '2 ' v !� 24 hour notice for all inspections(952)447-9850,fax(952)447-4245 114(5°' co* vRfo • Date Recd /NS\ CITY OF PRIOR LAKE PLUMBING PERMIT . ea • 4'hvivcsett' !'/c..ri W O7. ?.$#.. • I. Blue File PERMIT O.070700 2. Gold City V/ p 7 0 D 3 Yellow Applicant (Please type or print and sign at bottom) ADDRESS ZONING(office use) 39,0(v � 0-rICe. Na,LI) LEGAL DESCRIPTION(office use only) LOT BLOCK ADDITION rr PID Z$',4143. 037. 6 OWNER /� /) J ^ 'l 'I 1 .S*Ll►1O/(J 6a-1-124.7--q j�LI�'_g�0� (Name) Li tri en— T r to r L-c�fl. 4*� (Phone) (Address) q Let-Hp dJ O*i �- .E_.. tVyI o r Late_. I ►t�-i? APPLrTb0kVYd3 `1i n i- l�'1eu-'r'1 (Phone) 50--- �3`7 '6409 (Address) 6 l r t- a-d l k aAat 5 .9- (Address) 'DV() ' (City) (Zip Code) (Contact Person) —TO'rYM (1-:3-1) 1J V0 r al)-- , (Phone) 5O -3314- lq'Oq APPLICANT SIGNATURE )01'..4 J Vz),01K DATE APPLICANT PLEASE COMPLETE BELOW Quantity Type of Fixture Quantity Type of Fixture Bath Tub with or without shower Rough-ins i Dishwasher 3 Water Heater Floor Drain 1 Water Softner 3 Lavatory(Bathroom Sink) / Stand Pipe(Washing Machine) Laundry Tray(1 or 2 compartment sink Sewage Ejector 'Z. Shower Stall t Backflow Assembly '1 Sinks Backflow Assembly Test Bar Sink ( Lawn Sprinkler Water Closet(Toilet) Other FEE SCHEDULE Industrial,Commercial&Multi-family 1%of job cost with a $39.50 minimum Residential,New One&Two-Family $99.50 Residential,Additions&Alterations $39.50 Estimated Cost $ T4! i'. 00 — Building Permit# PLUMBING PERMIT FEE $ /l 1-171 S . 00 IZGC-/� Ch'C/t STATE SURCHARGE $ .50 F. /8. 07 -4444(1G7 TOTAL PERMIT FEE $ /f 1-1/5 . 5 O (Office Use Only) This Application Becomes Your Building Permit When Approved Paid Receipt No. / 474-3,50 5�6�¢— Ze,144-f-e-‘• Ve-419-1--)1 9/2-S/0 7 Date/� By Building Official Dates7. L I• d 7 i% 24 hour notice for all inspections(952)447-9850,fax(952)447-4245 16200 Eagle Creek Ave.,S.E.,Prior Lake,MN 55372-1714 04 pRto� CITY OF PRIOR LAKE BUILDING PERMIT, Date Rec'd t.Ak, TEMPORARY CERTIFICATE OF ZONING COMPLIANCE AND UTILITY CONNECTION PERMIT jNN E 50�� /2/1--6 t / 07- 0757 1.White File 2. Pink City PERMIT NO. 07 1196, 3.Yellow Applicant (Please type or print ADDRESS and sign at bottom) ,ONING(office use) 3c10G, 5T 11oR PcAcE NL) LEGAL DESCRIPTION(office use only) LOT BLOCK ADDITION PID OWNER n (Name) L, 11-7 or ( 'O'fc- Lis k-Ei (Phone) (Address) BUILDER/SPINKL.EK- Cohrr. ACrOr_- (Company Name) 43 SVT H t S f 1 e-s- P(eurEC l o N (Phone) 74,3 -4144/ -Z Z Q O (Contact Name) C g0-1 67 811.1 t-( (Phone) 76 3 -Z y I-3S B t (Address) clg5Q E_, Hwy, 10 , Et-L IzivEr_. t-114 55330 TYPE OF WORK gNew Construction ['Deck ❑Porch ['Re-Roofing ['Re-Siding ['Lower Level Finish 0 Fireplace ['Addition ❑Alteration ['Utility Connection pt.lCI[tE.-s?IZth1K-1+5g_ CODE: DI.R.C. INI.B.C. fisc: OF PA i - ZOO a. D, Type of Construction: I ® III IV V A 0p Occupancy Group: A 0 E F H I M R U PROJECT COST/VALUE $ 22/(100 Division: 1 2 3 4 5 (excluding land) I hereby certify that I have furnished information on this application which is to the best of my knowledge true and correct. I also certify that I am the owner or authorized agent for the above-mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with submitted plans. I am aware that the building official can rev this permit fo 'ust cause. Furthermore,I hereby agree that the city official or a designee may enter upon the property to perform needed inspections. X C-05.7 /2-/y-o7 Signature Contractor's License No. Date Permit ValuationPark Support Fee # $ Permit Fee $ 3 SAC Plan Check Fee $ Q447. t ' Water Meter Size 5/8";1"; $ State Surcharge $ /` A 50 0 Pressure Reducer $ Penalty $ 1 Sewer/Water Connection Fee # $ Plumbing Permit Fee $ Water Tower Fee # $ Mechanical Permit Fee $ Builder's Deposit $ Sewer&Water Permit Fee $ Other $ Gas Fireplace Permit Fee $ TOTAL DUE Cnj 372 jZ,Z 7, 67 $ 6113.86 P, ,Ap f i n Be'macs Your Building Permit When Approved Paid ef '43.8 6, Rece. No. _;"5708 L Date /Z, 1'7. 0'7 B‹ pi t— -- -7.47g Official ate This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and may proceed as requested. This document when signed by the City Planner constitutes a temporary Certificate of Zoning compliance and allows construction to commence. Before occupancy,a Certificate of Occupancy must be issued. Planning Director Date Special Conditions,if any 24 hour notice for all inspections(952)447-9850,fax(952)447-4245 4646 Dakota Street S.E.,Prior Lake,Minnesota 55372 P RI R DEPARTMENT OF LAKE BJJ LDING AND INSPECTION INSPECTION_RECORD QSITE ADDRESS 3'7 tosiATiof4 Puce N.0. NATURE OF WORK 11tE' st-gT1C* It 2 ?Rion. LAKE USE OF BUILDING T. - Occ alwcy 'TYPE ``B .fir . PERMIT NO. 0,... 0754 DATE ISSUED air* , a , CONTRACTOR DIET-CON CJSTA d"/OIU PHONE$' ?• SMS •II4I 7 ' NOTE: THIS IS NOT A PERMIT FOR ANY OF THE INSPECTIONS BELOW THE«PERMT IS BY SEPARATE DOCUMENT N $.0,-7 P ‘41.c., " big? 5iAL / • gEeortr EQ� 9 INSPECTOR DATE ( FOOTIN P� ab FOUNDATIOrior to Backfill) \\ PLACE NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED \_ &74£. aCO3G Oft ROUGH - INS fistioterimisidolx,' 3e#s'z . SEWER /WATER / SEPTIC FRAMING $4S L INSULATION ELECTRICAL PLUMBING UGw (0.z(0.61 HEATING (if required) r-" FIREPLACE 1 GAS LINE AIR TEST MY 3/ ,P .5// , COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED tt:Olt w1?. rs LATHc/AZ/4r,404s OS A 4t Sor4Jc. iso FINALS GRADING (Prior to Song) A? tii, BUILDING a o ELECTRICAL PLUMBING IJC & ; .5�/egg �/ /0 HEATING r 9/9 / 2 - DO NOT OCCUPY UNTIL ABOVE HAS BEEN SIGNED NOTICE This card must be posted near an electric.,91 service cabinet prior to rough-in inspections and maintained until all inspections have been approved. On buildings and additions where no service cabinet is available, card shall be placed near main entrance. FOR ALL INSPECTIONS (952) 447-9850 1 04 PRIp+? r s V' U of 14.27 eWhi -Buildin Canary -Engineer ng "''NNESo'`°' Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT � l Bt Laws( Tr al t N APPLICATION RECEIVED 9/m(07 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: 13 3 9 D 57—Nr; Tbk•CE— CFi g-€" 5T' c-t'i ons #`-2.) Accepted Accepted With Corrections k Denied Reviewed By: Date: 9/2-46/6 7 Comments: ierg.04 eti-Q ea-.Nee 4.4.07.AiLe=3)-4.) 9��,a d� ice'-+�r� • ..�..�i-r-- .A.ALa-c;4) 8/z 7 eez . „„ , ter — 47%5; 2/06, ,4 .4a41.1.c tfe, o, "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid.” Z PRI°4v ti to 451i -y� �� - ng nearing NNEs° Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT 41-41-60-4 ). r APPLICATION RECEIVED 9/(07 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: 2-) Accepted Accepted With Corrections Denied { , Reviewed By: Date: 0e/' 7 Comments: - Y&, / ,:e. -.� _ . -Z s-� • Z� Q f . G1,4 "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." fit IL 3 04 PRIo- ti tiU trl White -Building y� �� Canary -EngTneeer ng NNESO Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT 4 n .6 Atr li /V874/7 y APPLICATION RECEIVED ///� e 7 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: v,t io `ice-7"Z-t 1/ilg • 4.6a) Accepted Accepted With Corrections �-- Denied /Reviewed By: 44-42C2I--) Date: 9/2-0/0 7 Comments: , Ze.e9 104.-4.; 4o1-7 f a44 LL I ,o "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." PAGPio - `j[y.%,1 `•+ 4.rX15 �4 • T '� ' white -Building M, �P ry -Engineering NES Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT Ac k•L N P'C ! N O E CZ OA-DT-EL APPLICATION RECEIVED I2-/ S / The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: 39 © Co STAT1 r PLACE (Fr r r z) Accepted Accepted With Corrections Denied Reviewed By: V4-4-40) Date: 1/3/68 Comments: ieE71-,0 -t c. C'ZM./H. J773 s Mires C ni PLAN: L p t c. (.004-1 . 7 Ga. I UENri F'iais<ri o. Peat)ck .T c. Pk. e_.. 1,o w .4 c0 2. ()JD NTizo cs e P Auu 7 ? 5 tkt.4.7 bow.), r r .7 Fac 13 4 ' • D`W 3 R M ItAdilC�kc_ VE•1J i 1,A;t—Ta (, wt, sr►,0 k� DETE - 0� gip_ A in- Sys-(- -s G2.E7k g -T-14 AN( 2O06 C4 M, (,tNc.E'ss EX memank aP 604 /plc., A-t c-. Peh1en2. ti70•-+.r 'Thi.44��h 670-ext.;2 6. A- G/fie e F abf*c.C-- I J'eq-t.Eb +i'J o IJ A-r cn.Tet)li o7W PE7ao-TR ?v,'.B S l c- BE .l-7tt-e7) Fes- 334.0#(..e, 4"40 /Vie. eor'7,Q- "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." Ppkaze - z N U rn _ = ilii, y�NNES��P Canary -Engineering Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT T�U- Zt� CEI N D e GnED%E L APPLICATION RECEIVED / 2-/S10 7 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: 390 (0 ETATioi PLA-C6- (Fiez s i-IQ z) Accepted Accepted With Corrections ✓ Denied Reviewed By: Zie72-"J/E 7,07-- Date: //&/"d 8 Comments: IAS BC 13 q Co . b 0 3 . 3 .4 : g P,C.AN C(N e , 5 ft Act_ 'bc.: 1 u.2-1Q a-o A P2io 2 T F7 N A c, I`NSPe Ctloa f PEW— 309. z . 3 : Sys e-h-.. 4/4Wei ijG i o2TS "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." 13:51 FAX 507 334 8790 BAUERNFEIND GOEDTEL 0 001 8 AUERNFEIND OI?OEDTEL FAX MEMO 3105 Industrial Drive P.O. Box 278 Faribault, MN 55021 To: Bernie Feidt From: Chad Merritt Company: City of Prior Lake Project: Prior Lake Fire Station#2 Fax: 952-447-4245 Phone: 507-334-7951 Phone: 952-447-9850 Fax: 507-334-8790 Date: December 05,2007 Pages: 2 (Pages Including cover) Bernie, Here is our mechanical permit application for the Prior Lake Fire Station#2 project. Please review and get back to me with the correct fee. Tb arks, Chad Merritt e-mail address is : chad.merritt@becompanies.com 04 PRIp, CITY'S copy U tail White - Buildin• yl zP Canary - ngineenng Nxss° Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT H C�.� CCnJ Gridf APPLICATION RECEIVED 8/0/01 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: -310 (0 'TA-r(©ti PC�/-AC G Accepted Accepted With Corrections Denied Reviewed By: V-e-4-12A-d Date: i//3/0 7 Comments: i&od( iJ ' , . T A • da.ifg a6te0-1.".40:174p ot-f4 ett222.1 OE 49PRZ va-e -z. , f its e aA.� )ipe fix.off .•� i<1.4.ta 41,e; a if ac v►-o F , // 4/62 Gam. t -11-*,-4-4)• "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." of "1°4O ti U tr1 ildin �, �� i .Enring NxEs° Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT - Cb t CO►J ST('- .cc7 d APPLICATION RECEIVED e( B (a 7 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: Sci S T i Ti 61 eutcc Accepted Accepted With Corrections ✓ Denied Is Reviewed By: 7`v---`4C'�' Date: R(/3(6 7 Comments: `Y-) ATA-4- t-ee0 747 ; N l/rT J / >1f G� -41 111/ --A*/ 4-(7. b970_1±4,,_4„P 4," iii"‘ 14, SJ r r . 7.) 00N ,(1),"-I sT-r a LE "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." 190-15L 3 O1 PR/04 ti [-Seting_ -Buildin_.) y,Nso�r Canary - Engineering Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT itiS - 2i•-) Cn f )S(2,tA_C.77 at APPLICATION RECEIVED 8Veia 7 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: Accepted Accepted With Corrections ✓ Denied Reviewed By: Date: g/i 3,a 7 Comments: g) J "72.,c.o-ri,r..•q -44A-g-7-,--t-t6-g7 .. -71-c,._-"c .4..a_d_t,,,,--,-„,_t_,t6,0 ,i-crt-- Liu-(--;u 71a .-d„a)---e__ 74 ,tet DlQ. d ,-) - ,Z a- &e,�.,,�., Z� ;43e_e_A+."-auf- (PaG) / _I .126-t el V-L dx-cle-le -`& .,L_ 6— --Psz,7) -42-6 Ci-6*-7--je_ ii? :4-1-2rez"..,i-u)-r.--.) eft-taz_e___ c-c, e3-- --e-ei-x..-,- r a "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." tiO� PRIp e, u - - uildin y/ �A Canary -tng nearing NNESO Pink -Planning BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT PACE-T—— N Co OST 42.-cka^I D APPLICATION RECEIVED (S/ 7 The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: Accepted Accepted With Corrections Denied Reviewed By: Date: g)// 317 Comments: -exl) ./Le-rx4.4.e.7 �e�--2 Pi) .erf � 4771--` 8A707 "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." O1 PR/0,- �x U trf I •. a -Building_ INNEso�P •na - Engineerin• Pink -P arming BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT0 C` ` Cv� v^'Si-a-J GTS o.� APPLICATION RECEIVED £3/970 I The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: -2,10 Co ''T.4.--1-t C)A-0 --R.,,,,, --,- . Accepted 7C Accepted With Corrections Denied Reviewed By: e Date: Fr '3/p-7 Comments: As - C :II s v--..,s-- 6c C p v.,., (e 4 to( lo;r t 1.o r- -i-d Ger 4'•r'C a , _ 0 C7 C ( %ire. --- C • Co•--'I'cn C 932- 'ILI7 " //F30 - eJ'oS.,' a-. Co,..,-L- ( eitJ •' l•�-� `/ .- spec r-, ',--s "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." . PRIp .40 U =i White -Building �1NNEso�P Canary -En•ineering 1 - • arming BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST NAME OF APPLICANT 1.`. : �' _•�-���.1� T,,,--/ APPLICATION RECEIVED % �•`'/ -" The Building, Engineering, and Planning Departments have reviewed the building permit application for construction activity which is proposed at: - Accepted ✓ Accepted With Corrections Denied //�11 Reviewed By: cam• VaftztiA Date: �l 13)0q- Comments: as ,..fa r „want c tom, -ape#4...., "The issuance or granting of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid." 5Gia ' 1 f 3o/08 0 PR10 7C 4646 Dakota Street Southeast V erg Prior Lake,MN 55372 4iMNEsol t. January 30, 2008 Kaeko Leitch I&S Engineers & Architects 1409 N. Riverfront Drive Mankato, Minnesota 56001 RE: Backflow prevention for City of Prior Lake Fire Station#2, 3906 Station Place N.W. Dear Ms. Leitch, As discussed in our phone conversation on January 25, 2008, the City requests the reduced pressure zone backflow (RPZ) used for backflow prevention be substituted with alternate backflow prevention methods, such as an atmospheric vacuum breaker (AVB) or pressure vacuum breaker (PVB). By using devices such as these, the City can reduce the long term maintenance costs of yearly inspections and mandatory 5 year rebuilding of RPZ's. Also AVB's and PVB's are initially lower in material price than RPZ's. We suggest that the proposed 4" RPZ backflow protection of the service line to six truck fill bays and the 3/4" RPZ backflow protection on the service line for the pressure washer be substituted with six separate AVB's for the truck bay fills and that a manufacturer for the pressure washer be specified with a built-in air break tank. The proposed pressure washer, Landa model # VNG4-20024H is not supplied with an approved built-in air break tank. We suggest that a supplier that manufactures a pressure washer with an approved built-in air break be utilized, which would eliminate the need for an RPZ device. For the truck fill bays there are 2 alternative methods of installation acceptable to the Minnesota State Plumbing Code (MSPC) 4715.2100. A.) Atmospheric Vacuum Breaker. (1) Must be installed at least six inches above the spill line (see special requirements in part 4715.2150.) (2) No possibility of back pressure permitted. (3) Only permitted on discharge side of last control valve. (4) No more than 8 hours of continuous line pressure permitted. B.) Pressure Vacuum Breaker. (1) Must be installed at least 12" above spill line. (2) No possibility of back pressure permitted. (3) And continuous line pressure permitted. www.cityofpriorlake.com Phone 952.447.9800/ Fax 952.447.4263 This request is based on Plumbing plans dated August 24, 2007 that were submitted on September 18, 2007. Please provide supplemental drawings for the above conditions. If you have any questions or concerns, please call me at 952-447-9856. Sincerely, Bernie Feidt Plans Examiner/Building Inspector City of Prior Lake 4646 Dakota Street S.E. Prior Lake, Minnesota 55372-1714 952-447-9856 Email: bfeidt@cityofpriorlake.com Cc. Brian D. Gjerde, I&S Engineers and Architects, Inc. Marise A. Widmer, Minnesota Dept. of Health, Plumbing Division. Doug Hartman, City of Prior Lake Fire Chief "Test and Balancing" The air distribution system(s)have been tested and balanced to be totally operational and within design tolerance by Mechanical Data Corporation Prior Lake Fire Station #2 Jar Mechanical Contractor Bauernfeind Goedtel by Mechanical Data Corporation Bloomington, Minnesota Test Engineer ' C1-311`P 1, 1.271 Brandon Johnson,TBE (j) Certificate of Professional Independence Associated Air Balance Council TBE #05-04-32 Date September 26, 2008 2s. s... i !�\. .`rte. %ti .,------,-.L.;,.. =�=. ... i-i�. r� =• r< r� i--: �/ s,: '-f �V '+.'ir �i:=".``.mss'\ e� .• �/ s \' .:� �a s' �/r yrs ~�/ "dV v DC7 ..r�.•.;s<ap...�l..Rzs.. ...r,.t;R...F•�+o..s.er 24.,....{'ir:•:�sQ.:1Pi,'r`,:R;s..:ars.•;:s?.�::e:-....;r�:;i y�::or•"aipe.,:r-`.e::�..tif.R..„r„r,,',f'�.s..?sg h y..fi,+AF+'?a._�.,:ss_.di••^,:::�4wF.ey.+�?'.� �.�.•,#'I ����4�••�JIF�r••��� /* :$4:;N*:�,�4 ' �1���"i h1Nf'�`9ii,'**1 :yti�V'i2;3"V x;12; i1:�dO �i���(i �i���i•,' "4• ���i%,:i�f�4'.',.•.f4� •',W2, •'V�1f �����:,$), . l,�flff,, :Oi`f;1�1�.�4RR �,ff �1,�;flfllb �f�l�i. rl �1�i/� �� rll,�„f�'ii4,�R;��fl.>/R Ilhl 4. �� '��. Pl�i::�`c a�1� f�ii� fhhl �fP�In v,tlPif� .<1�hi �.,.,../f, ,.� +f+/ t 4,� ,�f1 o ti: f,;N f N 1 q1 'le it a,,t` iN ,. fV f/ o� ,•ff+N ;, +f,,, k+i, 4 N j.lf f rg' f+ �,N 1:0 4/1fN , 1 V44$�11 > } i tl!I �4ftt}Ifff.�t+t,tttts4'tN+ft.�tft,f yll+tt N1+yrfiit +ftta\ttft:4 itttf++t+:t tttt+t-ttt . ttttlt.s;tft,tt fft!ff 4'tiftf tHlot t4'11,1%, ff :' f ,—v ._ , u I._ ._ .. UV ,..t I .. t .. ._ .. .. 1 .. 1 :. ._ ._ u .. i .. I._, . X4,1 ,oleo�� .«, :44. (f•aae0 :-A,'13:4,4,' ' -`& rr ' I *1(� O, �\ aS " =s= v k .���a� r , •N 1+ w , �v w C V � • � w• O >� C2 • ti .. .v 1) ::::::::• • lit%ii 16$1...,,--_::,.. 0 1 c::, %4 G .4,....5,-, ,k,01)64 _ 1) of --h ''4``4...r.r.,..„.....,:_: ,„ 1 , -� �i t �1 0� v Is lec , ,t t tc ,cotsil ,zt ,..... e,.. 0.,4. ,,g,, \4x1,..... .„.._ 1 .0 1..._ ,.44 .'' S I 4 `/7th-"— ii_ tt O 0 z�<�. >rt �-o (I) d `ti ;145:.4.::, 04' 0 ,%..,.•- m c. • , (f h'!•—o.•--i, ' of '( 4 x,....0 11 JI A, �• q (t1i0��-"P'. ®.�®; • ,yam 111. 10A, -, �Sb * ,..„._J--•-14.•'.,1/ `�� � y�4If.�,, '( I'�!. �,�,ya ': � U� 'rl•:�;. t Vii. } ' :;4 flf ;; ;,�.t' - ,j �q ��, �,� ��� �uG a �'�'(, ;; �{� ,t ;,,ii is�viiif i. ti t li4 ►f .(. I t ,;..tll It � .{t 4 Ittit 44►f+ `'tilt t . t ,;,.t ft t tklf++ .t I1;�� tt , t� Its: ,4t t+ °,t -_ /,�q+:+.f, i+tf .,,N 4f r N t f t ,` ftot: . 4+f ,fit'' ,, 44 h f NfN; s 441+7 uN41N,, ,If4tt+a 4t+N : fl+i4+ , ll, 'Ape, t4' l fe'11,0't.,N4f+: •-.f4Nf, u:+4 i p,m Ifl•••• .y�llf" :yf{fn N{ :. !'�{f,: N t , :: :fN�t N . A!{Nft:_ ANI+.. VI,'�{Ilf� ,11,11+ ,�tltyNt, N f . : f{+f�. {II. N�+f��y. lit;eft: �p yf 41♦v�Jl'400.: us,y s v 41 yi4f P O 74t fi4i0 A4,40.4 t yyld�41.'v VA ji��yf�l�lp���i y++4&...SY,..,���is k.:41•l 44.0 �ti,j�.�s y/f/+�l/l. i0:1,1:43.4A-;.::::,,Ni i 4•.M: :e,� .:04.5<L.:O•:.11y a0•:.:Id..O.O�i.R�:,:❖4.R�.:•.4 .�:O.�i�I�. .�.�:.:••.:�:O.•:p��:t:'.:r;.:>�i:a!:,. . i,1,..�:O:�i: P.:b��i�6�.A:.•4 R��O..�i,:1;a:0•:. .. . � i:: _d yts,.asS.••.:4141 ; v+tt.A*it .•.Ae�,;:ies;:_$4114c:iW.. 10 --itilit.2 ;:iftt _ :rrs,.;E2_:l C.:•s.•- 0='• s.:•r' •:,.::.• - ••:.-a"--:;�,:.•�1 , \ 3 ��r_ \.•,..- y=ric .,„.. ...= /`y' \ ,.5- - __'` \ Q:i \y_l ,'\as�r� /\S.,-z3•i�S V „'. 0.�.n*s` >< '' '''it'''''''''''' ' C e 4 ''' ie 'iatedr aI ''sso4 4 Ant ,,rietrtifi �'e s'; *''''':':;741h114,g Oirir:. ' ' '''''''' ' ' H ' :'' ' ' ' E3 „, •,J:,, ---,;,„,,:-.,-..• • , '--,-,_ .' ' ' ' ''''' ' ' - ''' '-'' .r }n JthnSon 7,-, Mechanical Dat''' , h x, get 0 ii s r w„tr ,t 0 x � � A € , ,,t' r / / j ai '' '171e17141-. ' ' ' ' 0'- ' '' ' ''' '''''''' ' '- 1 / /, / ' '' ,x.,cerit.y crtc,P� 'fs 'c�ir� t't' �, CJ+ '. ' ,-,..,-----i,',AR:BAL,14,,c,:,:„.,,, ,...., ,, \,42--_ 47:''''''''” }° .4 4- ' -5 ''''''''''':' I - ---- - *,,, xerutive Director - ..200B `#' II THE CONCEPT The prime definition of air conditioning, as stated in the American Society of Heating, Refrigeration and Air Conditioning Engineers Guide, is the process of treating air so as to control simultaneously its temperature, humidity, movement, cleanliness, and final distribution to meet the requirements of the space to be conditioned. While each of the preceding air treatment processes individually contribute a specific function of producing human comfort or space conditioning, in practical application it is the coordinated action of all of these processes, each related to and influencing the others, that produces the final desired conditions. It is easy to see that if one or the other of these coordinated functions is not performing as it should, the final results of all will be affected. To produce this coordinated function is the basic and scientific function of the "Test and Balance Agency". Associated Air Balance Council 1518 K Street N.W. Washington, D.C. 20005 (202) 429-9440 Mechanical Data Corporation has been certified by the Associated Air Balance Council to be a true, independent testing and balancing agency. Mechanical Data Corporation has no financial ties or interplay with contractors, suppliers or designers. This enables us to remain unbiased professionals at all times. Mechanical Data Corporation has been certified under certification number 112146. Branden Johnson is a registered test engineer under certification number 05-04-32. Mechanical Data Corporation 6407 Cecilia Circle Bloomington, Minnesota 55439 �t . 9 51* (952) 473-1176 ;k ti (952) 473-2630 FAX ECHANICAL DATA CORPORATIONOrin Page No. 1 of 6 member of � Date:9/26/2008 Associated Air Balance Council I ■ EXHAUST FAN TEST JOB NAME PRIOR LAKE FIRE STATION#2 FAN NO. HVAC 1 HVAC 2 HVAC 3 MAU-1 MANUFACTURER Bryant Bryant Bryant Titan MODEL NO. CNPVP482 CNPVP482 CNPVP482 NA MOTOR HP NA (2) NA (2) NA (2) 3 VOLTAGE NA (2) NA (2) NA (2) 460 RATED AMPS NA (2) NA (2) NA (2) 4.2 ACTUAL AMPS NA (2) NA (2) NA (2) 3.6/3.4/3.6 REQUIRED FAN RPM NA (2) NA (2) NA (2) NA ACTUAL FAN RPM NA (2) NA (2) NA (2) NA REQUIRED SP NA NA NA -/-/.25 ACTUAL SP NA NA NA -/-/.34 REQUIRED CFM 1625 1500 1400 5500 ACTUAL CFM 1140 1275 (1) 1385 5535 LOCATION West West East 106 NOTES: (1)Direct drive fan on high speed. (2)Motor nameplate data inaccessible due to mounting bracket. MECHANICAL DATA CORPORATION CHANICAL DATA CORPORATION ■�^ Page No.2 of 6 member of — Date: 9/26/2008 Associated Air Balance Council 111 ■ DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM HVAC 1 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM 108 2-1 CD 1.0 200 200 140 140 140 140 108 2-2 CD 1.0 200 200 130 130 130 130 110 2-3 CD 1.0 150 150 50 50 50 50 112 2-4 CD 1.0 100 100 60 60 60 60 114 2-5 CD 1.0 250 250 190 190 190 190 115 2-6 CD 1.0 250 250 190 190 190 190 113 2-7 CD 1.0 150 150 140 140 140 140 107 2-8 CD 1.0 75 75 100 100 70 70 107 2-9 CD 1.0 75 75 110 110 100 100 (2) 109 2-10 CD 1.0 75 75 100 100 70 70 SYSTEM TOTAL 1525 1210 1140 (1) Notes: (1)Direct drive fan on high speed. (2)Unable to access individual balancing damper. MECHANICAL DATA CORPORATION ECHANICAL DATA CORPORATIONPage No.3 of 6 member of ■'^ �:'.'� Date: 9/26/2008 Associated Air Balance Council IIIIII DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM HVAC 2 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM 107 1-1 CD 1.0 175 175 175 175 180 180 107 1-2 CD 1.0 175 175 175 175 180 180 109 1-3 CD 1.0 50 50 80 80 50 50 111 1-4 CD 1.0 200 200 100 100 150 150 117 1-5 CD 1.0 200 200 130 130 140 140 116 1-6 CD 1.0 200 200 150 150 175 175 118 1-7 CD 1.0 75 75 95 95 60 60 118 1-8 CD 1.0 125 125 50 50 90 90 119 1-9 CD 1.0 200 200 140 140 160 160 Mech 1-10 CD 1.0 100 100 125 125 90 90 SYSTEM TOTAL 1500 1220 1275 (1) Notes: (1)Direct drive fan on high speed. MECHANICAL DATA CORPORATION ECHANICAL DATA CORPORATION ■TIn Page No.4 of 6 member of Date:9/26/2008 Associated Air Balance Council ____ DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM HVAC 3 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM Mech 3-1 CD 1.0 200 200 330 330 190 190 122 3-2 CD 1.0 75 75 135 135 70 70 122 3-3 CD 1.0 75 75 140 140 70 70 122 3-4 CD 1.0 125 125 80 80 115 115 122 3-5 CD 1.0 125 125 70 70 115 115 123 3-6 CD 1.0 50 50 30 30 50 50 120 3-7 CD 1.0 200 200 170 170 200 200 122 3-8 CD 1.0 200 200 180 180 210 210 122 3-9 CD 1.0 200 200 170 170 205 205 116 3-10 CD 1.0 150 130 130 130 160 160 SYSTEM TOTAL 1400 1435 1385 Notes: MECHANICAL DATA CORPORATION CHANICAL DATA CORPORATION lir^ Page No. 5 of 6 member of Date: 9/26/2008 Associated Air Balance Council III ■ EXHAUST FAN TEST JOB NAME PRIOR LAKE FIRE STATION#2 FAN NO. EF-1 EF-2 EF-3 EF-4 ERV-1 MANUFACTURER NA (1) Greenheck Greenheck Greenheck Renewaire MODEL NO. 1 (1) SE1-16 SP B90 SP B90 NA MOTOR HP 1 (1) 1/6 Fractional Fractional 1.5 VOLTAGE 460 115 115 115 460 RATED AMPS 6.4 3.0 .7 .7 2.4 ACTUAL AMPS 6.0/5.7/5.6 2.4 .7 .7 2.4 REQUIRED FAN NA 1075 900 900 NA RPM ACTUAL FAN RPM NA 1075 890 910 NA REQUIRED CFM 5500 1190 73 73 1125 ACTUAL CFM 5460 2162 (1) 75 65 1125 LOCATION 106 106 104 103 East NOTES: (1)Running backwards. MECHANICAL DATA CORPORATION ECHANICAL DATA CORPORATIONPage No. 6 of 6 member of ■'^ L','.� Date: 9/26/2008 Associated Air Balance Council IIIII DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM ERV 1 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM EXHAUST 114 1-1 CD 1.0 300 300 280 280 280 280 115 1-2 CD 1.0 300 300 280 280 280 280 112 1-3 CD 1.0 75 75 130 130 (1) 130 130 (1) 113 1-4 CD 1.0 75 75 165 165 (1) 165 165 (1) 113 1-5 CD 1.0 220 220 260 260 260 260 112 1-6 CD 1.0 155 155 130 130 130 130 1125 1235 1235 SUPPLY Ava11 1 10X10 .56 1004 562 1333 746 1333 746 Ava12 2 10X10 .56 1005 563 1615 904 1615 904 1125 1650 (2) 1650 (2) Notes: (1)Unable to access balancing dampers above sheetrock ceiling. (2)Unable to adjust CFM speed due to inaccessible tension adjustment bolts in unit. MECHANICAL DATA CORPORATION AUG-28-20a? :.6:11 ' CITS COPY AUG 2 9 2007 MINNESOTA DEPARTMENT OF LABOR AND INDUSTRY By Division of Construction Codes and Licensing ' I L • PL'. Plans and specifications on plumbing: Prior Lake Fire Station No,2, 3906 Station Place Northwest, Prior Lake, Scott County,Minnesota,Plan No.085100 OWNERSHIP: City of Prior Lake,c/o Mr.Frank Boyles, Manager,Prior Lake City Hall, 16200 Eagle Creek Avenue SE,Prior Lake,Minnesate 55372-1787 SUBMITTER(S): I&S Engineers,Inc., 1409 North Riverfront Drive,P.O.Box 1026,Mankato,Minnesota 56002-1026 Plans Dated; August 17,2007,and fax dated August 23,2007 4 gg; Date Received: August 23,2007,August 22,2007,August 20,2007,July 12,2007 Date Reviewed: August 23,2007 SCOPE: This review is limited to the design of this particular project only insofar as the provisions of the Minnesota Plumbing Code, as amended,apply,and does not cover the water supply or sewerage system to which this plumbing system is connected. The review is based upon the supposition that the data on which the design is based are correct,and that necessary legal authority has been obtained to construct the project. The responsibility for the design of structural features and the efficiency of equipment must be taken by the project designer. Approval is contingent upon satisfactory disposition of any requirements included in this report. Special care should be taken to insure that the material and installation of the plumbing system are in accordance with the provisions of the Minnesota Plumbing Code. A copy of the approved plans and specifications should be retained at the project location for future reference. INSPECTIONS: i tallations must be tested` inspected in accordance with the requirements of All plumbing ens and A the Minnesota Plumbing Code. As specified in Minnesota Rules,part 4715:2830,no plumbing work may be covered prior to completing the required tests and inspections. Provisions must be made for applying an air test at the time of the roughing-in inspection as outlined in Minnesota Rules,part 4715.2820,subpart 2,of the code. A manometer test,as specified in Minnesota Rules,part 4715.2820,subpart 3,is required at the time of the finished plumbing inspection. It is the responsibility of the contractor/installer to notify the Minnesota Department of Labor and Industry when an installation for a state contract job,licensed facility,or project in an area where there is no local administrative authority is ready for an inspection and test. To schedule inspections, contact the state plumbing standards representative for your region,or call Tim Peterson at 651/284.5889, REQUIREMENT(S) 1. A minimum horizontal separation of 10 feet must be maintained between the water service and any sewer, whenever possible. No underground sections of building drain and buildingsewer pipe may be located within 10 feet horizontally of underground water service pipe unless prior approval is given by the administrative authority. Construction must be in accordance with Minnesota Rules,part 4715.1710, subpart 2. 2. The water service lino must be installed at least 10 feet horizontally front any manhole,catchbasin,or any other potential source of contamination(see Minnesota:Rules,part 4715,1710, subpart 3). This isolation i 3 distance must be measured from the outer edge of the pipe and the outer edge of the contamination source. Verify that catchbasin CBS shown on the Site Utility Plan,Sheet No.C2.11 complies with this requirement. 3. Catchbasin CB6 appears to be shown located less than 10 feet from the building on the Site Utility Plan, Sheet No, C2.1 I. All portions of the storm sewer system located within 10 feet of the building or water service line must be tested in accordance with Minnesota Rules,part 4715.2820. PJ0-2e-2r?a? sS:12 P Prior Lake fire Station To, 2 Plumbing Plan No.0E15100 Page 3 August 23,2007 10. The potable water distribution branch serving the truck fill lines is shown provided with an RPZ backflow or preventer on the submitted plans. Even though the plumbing code states that a backflow preventer must not • be installed more than 6 feet above the finished floor,it is more important that the backflow preventer be installed at least 12 inches above the fill opening of the fire truck In other words,the RPZ must be installed c�F at least 12 inches above the fill opening of the fire truck and the maximum height of 6 feet above the u il3 finished floor may be disregarded under these specie!circumstances. See Minnesota Rules,part 4715.210 IS • 11. The installation of reduced pressure zone backflow preventers is permitted only when periodic testing is IO p p� done by a trained backflow preventer tester acceptable to the administrative authority. Testing intervals l5 is4A shall not exceed one year,and records must be kept. All devices must be tested after initial installation to ssure that debris from the piping installation has not interfered with the functioning of the device, The saPfjo2 ( devices shall be overhauled at least once every five years. The installation of new backflow preventers must be at least 12 inches,but not more than 6 feet above the finished floor or ground level. This is in reference to the RPZ connection on the potable water supply line to the truck fills and the wall hydrant,and the potable water supply to the pressure washer. 12, Water supply connections to fixtures or equipment which have submerged inlets,or inlets below the spill line of the fixture or equipment, must be provided with an air gap arrangement,approved backflow preventer or backflow preventer assembly as specified in Minnesota Rules,part 4715.2000 and part 4715.2010. This shall include the potable water connections to the refrigerator ice makers,the clothes washer,the extractor,and all potable water connections to equipment not shown. 13. The submitted plans show dual water distribution systems within the facility, one potable water and the other nonpotable, The nonpotable water distribution system must be labeled nonpotable in accordance with Minnesota Rules,part 4715.1910. Points of outlets for nonpotable water shall be marked with a tag or color coded(see Minnesota Rules, part 4715.1910,subpart 2). This shall include the wall hydrant and truck fills located downstream of tire RPZ, the pressure washer outlets,and all water connections to the nonpotable water. 14. The direct connection between a potable water supply and the lawn irrigation system shall be provided with an approved backflow preventer in accordance with Minnesota Rules,part 4715.2110,T,and part 4715.2100. A pressure vacuum breaker is shown as the backflow protection on the lawn sprinkler system, Sheet No.M1.31. This backflow preventer is only allowed where no back pressure is possible. 15. If a chemical soap dispenser system will be installed on the mop sink faucet or any other sink faucet,then the installation of backflow preventers for chemical/soap dispensing systems must comply with ASSE Standard 1055. Exception:An atmospheric vacuum breaker integrally mounted on a faucet that is connected to a chemical/soap dispenser must be protected against back pressure by the installation of a pressure bleeding device and a backflow preventer complying with ASSE Standard I052. The backflow preventer must be installed on the side outlet of the pressure bleeding device, No wye connector that has an integral shutoff may be connected to a faucet that has an integral atmospheric vacuum breaker. Sec Minnesota Rides,part 4715.2165, f LI-28-20717 16:12 P.05 Prior Lake Fire Station No.2 Plumbing Plan No.085100 Page 5 August 23,2007 NOTE(S): 1. The scope of this project consists of the construction of a new building. The plumbing installation includes water closets,a urinal,lavatories,an electric water cooler,showers,an emergency eyewash/shower unit, hose bibbs,wall hydrants, a three-compartment sink,a clothes washer and washer box,an extractor,break room kitchen sinks,a dishwasher,refrigerator ice makers,a pressure washer,truck fills,trench drains,floor drains,a water softener, water heaters,an irrigation system,and a fire sprinklers system. 2. This facility will be served by new municipal sewer and water service connections. 3. The Minnesota Plumbing Code is available on our website at::www d t II..tate.mn.us/.1 ;���,e tm iI Authorization for construction in accordance with the approved plans maybe withdrawn if construction is not undertaken within a period of two years. The fact that the plans have been approved does not necessarily mean that recommendations or requirements for change will not be made at some later time when changed conditions, additional information,or advanced knowledge make improvements necessary. Approved: 4 Manse A.Widmer Public.Health Engineer Plumbing Plan Review and Inspections Unit 443 Lafayette Road North St.Paul,Minnesota 55155-4343 651/284-5887 MAW:ss cc: I&S Engineers.Inc. City of Prior Lake Mr.Robert Hutchins,Building Official File TO1PL P.05 13 R1 p4P Engineering Department � ; City of Prior Lake 0.4 4646 Dakota Street S.E. Prior Lake, MN 55372 V tri MEMORANDUM jNNESo`c' TO: Jake Rysaby Met Con Companies FROM: Nate Briese, Engineering Tech II DATE: Tuesday, July 01, 2008 RE: Punch list for fire station #2 After conducting a walk thru of the fire station #2 site, here are a few items that Engineering needs to be completed: 1. Need utility asbuilts 2. Contact Ross Bintner about rain garden grading issues @ 952-447-9831 3. Ok for T.C.O. H:\firestation#2.doc Minnesota Department of Labor and Industry Construction Codes and Licensing Division j Building Codes and Standards 443 Lafayette Road N.,St.Paul,MN 55155-4341 SITE COPY , Phone: (651)284-5068 Fax: (651)284-5749 www.doli.state.mn.us TTY: (651)297-4198 Special Structural Testing and Inspection Program Summary Schedule Project Name Prior Lake Fire Station#2 Project No.06-10076 Location Prior Lake, Minnesota Permit No. (1) Technical (2) Type of Specific Report Assigned Section Article Description(3) Inspector(4) Frequency(5) Firm(6) 1704.3 1704.3.1 Steel Construction-Welding SI-S All Field Welds AET 1704.3 1704.3.2 Steel Construction-Details SI-S All Field AET Connections 1704.3 1704.3.3 Steel Construction-High SI-S All Bolted AET Strength Bolts Connections 1704.4 1704.4.1 Concrete-Materials TA Daily AET 1704.5 1704.5.3 Masonry-Level 2 Special SI-S,TA Continuous AET Inspections 1704.7 1704.7.3 Soils-In-place Density TA Building Corners AET Note: This schedule shall be filled out and included in a Special Structural Testing and Inspection Program. (If not otherwise specified,assumed program will be"Guidelines for Special Inspection&Testing"as contained in the State Building Code and as modified by the state adopted IBC.) *A complete specification-ready program can be downloaded directly by visiting CASE/MN at www.cecm.org* (1) Permit No.to be provided by the Building Official (2) Referenced to the specific technical scope section in the program. (3) Use descriptions per IBC Chapter 17,as adopted by Minnesota State Building Code. (4) Special Inspector-Technical (SIT); Special Inspector-Structural (SIS) (5) Weekly, monthly, per test/inspection, per floor,etc. (6) Name of Firm contracted to perform services. • ACKNOWLEDGEMENTS ////�� (Each appropriate representative shall sign below) Owner: vr� Firm: City of Prior Lake Date: /J7 7 Contractor: __� Firm: Met-Con Companies Date:entio7 Architect:f es b. i,"...4„.. Firm: 1&S Engineers&Architects, Inc. Date: /t5/07 SER: ,.Lo._- 0 .),�^,�' Firm: l&S Engineers&Architects, Inc. Date: Wills? //�'1'�''l Firm: American Engineering Testine SI-S:(..... 4,1,4 �// .. Date: � ii'w I TAS OJ`i,/,.,, _M Firm: American Engineering Testing Date: 8-.t-o F: ��'� Firm: Date: If requested by engineer/architect of record or building official, the individual names of all prospective special inspectors and the work they intend to observe shall be identified as an attachment. Legend: SER=Structural Engineer of Record SI-T=Special Inspector-Technical TA = Testing Agency SI-S=Special Inspector-Structural F=Fabricator • Accepted for the Building Department By-----. I2 .e 2J-J Date j GQ d7 05/07 t'R598 MANKATO FARIBAULT s GRoup 1409 N Riverfront Dr 1415 Town Square In ` www.is-grp.com Mankato, MN 56001 Foribault, MN 55021 PH: 507.387.6651 PH: 507.331.1500 One firm-start to finish'" EX: 507.387.3583 FX: 507.331.1501 April 24, 2008 ARCHITECTS • ENGINEERS • PLANNERS • LAND SURVEYORS • SCIENTISTS Paul Baumgartner Building Inspector City of Prior Lake 4646 Dakota Street SE Prior Lake, MN 55372-1714 kF City of Prior Lake Fire Station#2—City of Prior Lake Project No. 06-190 Dear Mr. Baumgartner: The following response is to address the items brought forth during our meeting at the jobsite on April 16, 2008: . Windows: The window units were installed during the fall of 2008 in order to close up the building before winter. . 2. I:io `:,,stem• The ElF System is being installed now. Normally the ElF System is in place nrio:•to the installation of the window units. In this case, the grid tape and backstop coating itte Iaeing placed at the surround 2 to 3 inches into the opening. The existing shims do not interrupt the continuity of the backstopping and grid tape installation. :>. hacker rod and sealant: The backer rod shall be closed cell of the size necessary to be compressed into place at all window heads,jambs, and sills. The backer rod shall be continuous (lap at breaks)at opening surrounds. The sealant shall be placed per the specifications. Both the sealant and the backer rod shall be compatible with the ETF system. 4. Window sills: The window sill courses are rock-face concrete block sill units. The backer I ,' .11 i placed l . d .. _: ��3. .i t the scaling ii 1, 1 Alin �trilltlit shall be �.ilw.�G•:x �iJ I1�.)tCU.�a�� fr.J). The functionality of«,C. a�it.i$n�% $y.+l.t;i➢: 7;.;.:,1� be an equivalent to water-tight standards. it was a pleasure meeting you. Should you have any further questions or require additional information, please do not hesitate to contact me. Respectfully. Gary Fahl. A1.A Senior Architect Enclosure: Letter from Lutz Company, Dated April 16, 2008 CC: .lake Rysavy, Project Manager---Met-Con LUTZ COMPANY www.lutzcompany.com 8801 Xylon Avenue North 763-315-5886 Brooklyn Park, MN 55445 763-315-5891 (fax) April 16, 2008 Mr. Gary Walfred Fahl I&S Group 1415 Town Square Lane Faribault, MN 55021 Re: Prior Lake Fire Station Dear Gary: Thank you for taking the time to meet on the jobsite with myself and City Inspector Paul Baumgartner and contractor Chris Miller. I believe we satisfied Paul's concerns regarding the window openings in the EIF System being coated with Dryvit Backstop and having no exposed raw sheathing edges or openings. Since no EIFS is present at the sill condition or within 16"from bottom of jambs at the sill, the Backstop coating at window openings in conjunction with metal flashing at the window head will satisfy the Dryvit standard for a moisture drainage system. It was a pleasure talking with you onsite. If you have any questions or need any additional information,please don't hesitate to contact me. Sincerely, Erin Anderson Lutz Company Cc: Chris Miller—Trowel Trades Dryvit Systems and Finishes ■ Venetian Plasters ■ Drywall and Plaster Accessories "Test and Balancing" The air distribution system(s)have been tested and balanced to be totally operational and within design tolerance by Mechanical Data Corporation Prior Lake Fire Station #2 for Mechanical Contractor Bauernfeind Goedtel by Mechanical Data Corporation Bloomington, Minnesota Test Engineer Brandon Johnson,TBE Certificate of Professional Independence Associated Air Balance Council TBE #05-04-32 Date September 26, 2008 / s/ ,, ,r•••;,•...-,-7.F\.FsY"'ZZ,sr.:hsS\,4"17tr+�r- ,..1.7,"=.,/..C7:11‘.+ .`1- V_s'c '' /- �ir'c_�'a /r1 _ ,I,..�i.•d S•444•+• ♦•.•"4 04M.•+ ...p-•.•+•t V:.y.+✓.: y. ..s•••p.'Y�..s.•:O•r,•c_;�..:47 ,. :Ke*%;1; a 4%'.,AA'sS.. 4:4:+l'iie.�',�'•F�'••ag•✓sy�-s 3A.'t"1"kiP .4'.•zs3A� : 1lli•�If 4+`.!1 f 1�i`�f . I t.tY�t..... P • 4•.�J'iO4i•.d 0 �i..d4 •i.•O .Oji•.•++F��•i.•+++�O�i•.•+C��O'.;.•Jtl1�i.;:d ii4'.;.'+4fViP •+• �i t'..�i S�+ s 1r� t4f r t r. .t' 1 4 . 0v it' t'0 r •h '.,•e s q4:,��P!!4>��,/+17�.�R t9E �Rt�P! !���0`►q►f�'Pih�,��� '+'P►��!rr+Pr'Pi��•FPP! �:Pti ,y'�irraa�f',,,4414+ ,;1 NN '; f/ Ittf$ , �ffflf i N'f'ki, Atii4,,,,, Ayf,, e'? }2 ► e, , ,f tlft}yf, �h1tft,• 4ftf ; offs' t�ftt' Of}Iti Vili}Ot.'fInfif1 ' f► 'J n Cil.flft;')0. tl,o�`ti �f � sM •r. T l u a e.1\ 40,.... .- -_-,-_ --,, �. Cry tAm hitt`: l -.,•4`%� w \4.I j .Jd/ i \r+ .,,�r► tt ', 'O Y3.i �\ N O 0' •1.1 ;i r yv:`•Its•'t�}� 1 ,-y,---4i.:1:1 Q dl �r�. 4.4 ta EI '":4,,z,i-,:‘ 1S CI or* 44 ,VV�`s- ` L 3 ::::41:44.: i› y+ePv + y ,,,...„-=------, ,------:: /►�• IvS . • te. Q 1 0 ea to 0050t,* oft "izt tt s.• iCl A. ) U •H'fire :--__,!..,,,_f ....7 in by �3�,:4_ if. ° c..) ee q N „, ' ttl �yR.l+.a 4 l r :} IP-, :t \�=s . '' ■� • U O1 a •._ may+ '{<�. hitt¢; 7 ^ o".'i d 1� r.14 0 Al F N 11 1-7-:____::......7--:=::::::::.&:,..k4 r� ,-?Sl^, t` OI £24 /:iNCit*d :. L> Pt Liv, Cr N ,.. III .`may �1 rrir�Z'�.�.�Iq o"t,., 11 tY i 41 -4 if ii,v'ff+4 `4 f lfiltli �I, II 4' 41►1 I,1 :') 1 1 11114 f t .lfl'll 4, -/ `''' ' 9 '' r�.cs:''' 4,041-IT 411 .'r l+f�p a, f tone,f tit,.. i ft 0 `4 of} ; 4)0 ,,441'ofte, .'444+r54411#444*ftilt� b l tl a 1';Afli l', f:1+1 :,�,r f,'11;„.11�f,.,,f ii 1,1 4i A it II r.i11 ii I)i •. ., ,0.:.r i k '140i' s.4t4'•t•: .tS,Ff+l+,: , i{11,. .Si+k. i4i r. rf1 is YAN+, 0444* 31S,NO`'',111}8. <N I} Vifri l i ' f4f1„ ff if.,:':.ffl er,s4 41 Itaistr `•.�+�•� 444 4*4 4.`.`P+4 14+N+4r ill+9 0,/l+9 4.I Ago#4 IY tm0,to y/ is+�+`�0/rl�ltltll i i 4/111#.: 1+f11 0:(1'14,141' 4,.44 le /441 i ,lN+il1+�, 4?4 irl+: •+.�• ►I:i+11, YL.,,,,r_'" .+:..!....-+•.�e.:+•.,.,+....t.:.:.:.4+44.:,�4;..:...! ..:::40,it.::•I��004.:.pp�).4 sU+:•,••0 p•••••••4 14+•••1••4!•411+•.•••�i.•4i4 4...4..14••4....S.41, 414.4.1••04 tt, •i•.••14 \-4.4-e.nc�..:&w• •ws._ �.y�se L.;1.0- .y.y. - a. o .�•.e;;g::$...c.S•+•. A.:yew•-yl,.•�i� ..t.: :.6+!.;t-•:e: iRyi 3 ryah'£' kk- -„,,,.., , , ,, , '''' ' ' ' ' ' '''' ' '' ' '' ' '''','22'2'.-',22.•-;.,,r,::'?'-'''':;:-.'''''.:C ''' ' 2442,;:$,9 +II Assoc rate 4f BaI ante Co rn �� x a, s --'' . =2-- '2 2 2. .,-- ' . , ' . ' .. Aii r I' ���rth atto .2,,'-.-,,,„,.,-, , ,:22 ' .- F r e„22_ sowr ,-2,-,-,;,'2....',2::.,' ,'' r'' ''' .”.' ' ' '.i':' • • •, ;•;mec22. ® �� ° s ' dti , ,,,, - ,.,, ,,,„:,,,,.,,,,,, , , .. ,. ...,, , :,: • ,,,,, . ....,. .,,,,:,,:-,:. .. ,. j1 3t eT `�t '' ,,...i,,, . .. ,, /,,:7,40(ze.:::.., ,,,,,,, , , < 4 ro :e..: , _.„,.. , ,. ., ,,, , . ,. '*-.,_-....;:...,;..[,-,-,-,--;,-i' YS! L J ','-z--'-",,,--.,:'.:. .-2,;1_,,,'_'-',,::,,.-.:.:,,:-'--,---,;- £ -s5 4 .fie s' t /d !, ® } la.[l-,Zi��,� i/�'.`�E'l a 6 d O`4 ,-/I , er `ems t$ � } f-gys' 6F ( � � ., , ',-"-'-•,,,.,:i.,•4.,.'`,"..'."':':.„* '...,‘,*' ,,..,, /. ., ,,,,,,(eisci.,,,c4,4,et4:00,2 , .;'',4- ''' ,,, . .,4f,&„..' '..i''''',':;`..;;;;••I'''''-ii. .t.,,,,, .. . , ' :,, .. i.,,,,„;,,,.. :, , ',, ,nzeiizetyf,;,„ '.. .. . ,, ,Wa ''-, ':. , ., . 2' ' ', '''-',444,_cy, .,?c ,,,,,:,,t;,,,,•-•,;:f.awr, Hot.7:22.7,,,:,‘,2,,..,i ,,- ' f �r : � �rrci/t� :cate e� " e . tY/, �WO :�� �� Pres en ,,,.(..,:'1 ; •' it, - xecuiv I?irettar y THE CONCEPT The prime definition of air conditioning, as stated in the American Society of Heating, Refrigeration and Air Conditioning Engineers Guide, is the process of treating air so as to control simultaneously its temperature, humidity, movement, cleanliness, and final distribution to meet the requirements of the space to be conditioned. While each of the preceding air treatment processes individually contribute a specific function of producing human comfort or space conditioning, in practical application it is the coordinated action of all of these processes, each related to and influencing the others, that produces the final desired conditions. It is easy to see that if one or the other of these coordinated functions is not performing as it should, the final results of all will be affected. To produce this coordinated function is the basic and scientific function of the "Test and Balance Agency". Associated Air Balance Council 1518 K Street N.W. Washington, D.C. 20005 (202) 429-9440 Mechanical Data Corporation has been certified by the Associated Air Balance Council to be a true, independent testing and balancing agency. Mechanical Data Corporation has no financial ties or interplay with contractors, suppliers or designers. This enables us to remain unbiased professionals at all times. Mechanical Data Corporation has been certified under certification number 112146. Branden Johnson is a registered test engineer under certification number 05-04-32. Mechanical Data Corporation 6407 Cecilia Circle Bloomington, Minnesota 55439 (952) 473-1176 (952) 473-2630 FAX MECHANICAL DATA CORPORATION Page No. 1 of 6 member of11172 Date:9/26/2008 Associated Air Balance Council ■■ EXHAUST FAN TEST JOB NAME PRIOR LAKE FIRE STATION#2 FAN NO. HVAC 1 HVAC 2 HVAC 3 MAU-1 MANUFACTURER Bryant Bryant Bryant Titan MODEL NO. CNPVP482 CNPVP482 CNPVP482 NA MOTOR HP NA (2) NA (2) NA (2) 3 VOLTAGE NA (2) NA (2) NA (2) 460 RATED AMPS NA (2) NA (2) NA (2) 4.2 ACTUAL AMPS NA (2) NA (2) NA (2) 3.6/3.4/3.6 REQUIRED FAN RPM NA (2) NA (2) NA (2) NA ACTUAL FAN RPM NA (2) NA (2) NA (2) NA REQUIRED SP NA NA NA -/-/.25 ACTUAL SP NA NA NA -/-/.34 REQUIRED CFM 1625 1500 1400 5500 ACTUAL CFM 1140 1275 (1) 1385 5535 LOCATION West West East j 106 NOTES: (1)Direct drive fan on high speed. (2)Motor nameplate data inaccessible due to mounting bracket. MECHANICAL DATA CORPORATION MECHANICAL DATA CORPORATION ■r^ Page No.2 of 6 member of — Date:9/26/2008 Associated Air Balance Council III ■ DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM HVAC 1 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM 108 2-1 CD 1.0 200 200 140 140 140 140 108 2-2 CD 1.0 200 200 130 130 130 130 110 2-3 CD 1.0 150 150 50 50 50 50 112 2-4 CD 1.0 100 100 60 60 60 60 114 2-5 CD 1.0 250 250 190 190 190 190 115 2-6 CD 1.0 250 250 190 190 190 190 113 2-7 CD 1.0 150 150 140 140 140 140 107 2-8 CD 1.0 75 75 100 100 70 70 107 2-9 CD 1.0 75 75 110 110 100 100 (2) 109 2-10 CD 1.0 75 75 100 100 70 70 SYSTEM TOTAL 1525 1210 1140 (1) Notes: (1)Direct drive fan on high speed. (2)Unable to access individual balancing damper. MECHANICAL DATA CORPORATION MECHANICAL DATA CORPORATION1.1 Page No.3 of 6 member of ■ ., Date:9/26/2008 Associated Air Balance Council 1111 ■ DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM HVAC 2 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM 107 1-1 CD 1.0 175 175 175 175 180 180 107 1-2 CD 1.0 175 175 175 175 180 180 109 1-3 CD 1.0 50 50 80 80 50 50 111 1-4 CD 1.0 200 200 100 100 150 150 117 1-5 CD 1.0 200 200 130 130 140 140 116 1-6 CD 1.0 200 200 150 150 175 175 118 1-7 CD 1.0 75 75 95 95 60 60 118 1-8 CD 1.0 125 125 50 50 90 90 119 1-9 CD 1.0 200 200 140 140 160 160 Mech 1-10 CD 1.0 100 100 125 125 90 90 SYSTEM TOTAL 1500 1220 1275 (1) Notes: (1)Direct drive fan on high speed. MECHANICAL DATA CORPORATION MECHANICAL DATA CORPORATION ■�^ Page No.4 of 6 member of -- Date:9/26/2008 Associated Air Balance Council III ■ DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM HVAC 3 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM Mech 3-1 CD 1.0 200 200 330 330 190 190 122 3-2 CD 1.0 75 75 135 135 70 70 122 3-3 CD 1.0 75 75 140 140 70 70 122 3-4 CD 1.0 125 125 80 80 115 115 122 3-5 CD 1.0 125 125 70 70 115 115 123 3-6 CD 1.0 50 50 30 30 50 50 120 3-7 CD 1.0 200 200 170 170 200 200 122 3-8 CD 1.0 200 200 180 180 210 210 122 3-9 CD 1.0 200 200 170 170 205 205 116 3-10 CD 1.0 150 150 130 130 160 160 SYSTEM TOTAL 1400 1435 1385 Notes: MECHANICAL DATA CORPORATION MECHANICAL DATA CORPORATION ■n^ Page No.5 of 6 member of — Date:9/26/2008 Associated Air Balance Council I ■ EXHAUST FAN TEST JOB NAME PRIOR LAKE FIRE STATION#2 FAN NO. EF-1 EF-2 EF-3 EF-4 ERV-1 MANUFACTURER NA (1) Greenheck Greenheck Greenheck Renewaire MODEL NO. 1 (1) SE1-16 SP B90 SP B90 NA MOTOR HP 1 (1) 1/6 Fractional Fractional 1.5 VOLTAGE 460 115 115 115 460 RATED AMPS 6.4 3.0 .7 .7 2.4 ACTUAL AMPS 6.0/5.7/5.6 2.4 .7 .7 2.4 REQUIRED FAN NA 1075 900 900 NA RPM ACTUAL FAN RPM NA 1075 890 910 NA REQUIRED CFM 5500 1190 73 73 1125 ACTUAL CFM 5460 2162 (1) 75 65 1125 LOCATION 106 106 104 103 East NOTES: (1)Running backwards. MECHANICAL DATA CORPORATION MECHANICAL DATA CORPORATION ■� Page No.6 of 6 member of Date: 9/26/2008 Associated Air Balance Council NM DIFFUSER AND GRILL TEST JOB NAME PRIOR LAKE FIRE STATION#2 SYSTEM ERV 1 ROOM OUTLET OUTLET "K" REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM EXHAUST 114 1-1 CD 1.0 300 300 280 280 280 280 115 1-2 CD 1.0 300 300 280 280 280 280 112 1-3 CD 1.0 75 75 130 130 (1) 130 130 (1) 113 1-4 CD 1.0 75 75 165 165 (1) 165 165 (1) 113 1-5 CD 1.0 220 220 260 260 260 260 112 1-6 CD 1.0 155 155 130 130 130 130 1125 1235 1235 SUPPLY Avail 1 10X10 .56 1004 562 1333 746 1333 746 Aval2 2 10X10 .56 1005 563 1615 904 1615 904 1125 1650 (2) 1650 (2) Notes: (1)Unable to access balancing dampers above sheetrock ceiling. (2)Unable to adjust CFM speed due to inaccessible tension adjustment bolts in unit. MECHANICAL DATA CORPORATION 4646 Dakota Street S.E. Prior Lake, MN 55372-1714 INNVESol? Fire Station # 2 Final List This list may not be complete Fire Alarm Final • Electrical Final • HVAC final 1. NO &CO ventilation test 2. Balance report • Building final .— 1. Address !2. Handicap site approach and access Special inspections for canopies Emergency and Exit light testing Generator start up review • Planning department approval (Already notified) • Engineering Department approval (Already notified) 1. Asbuilt utility plans 2. Additional drainage swale on north side of building www.cityofpriorlake.com Phone 952.447.9800 / Fax 952.447.4245 1E Metropolitan Council August 3, 2007 Bob Hutchins Building Official City of Prior Lake 4646 Dakota Street SE Prior Lake,MN 55372 Dear Mr. Hutchins: The Metropolitan Council Environmental Services(MCES) Division has determined SAC for the Fire Station#2 to be located at 3906 Station Place NW within the City of Prior Lake. This project should be charged 4 SAC Units,as determined below. SAC Units Charges: Office 518 sq.ft. @ 2400 sq. ft./SAC Unit 0.22 Conference 440 sq. ft. @ 1650 sq. ft./SAC Unit 0.27 Firefighters(volunteer) 19 people @ 14 people/SAC Unit 1.36 Vehicle Washing 5 vehicles @ 4 vehicles/SAC Unit 1.25 Hose Washing 1 hose washing @ 1 washing/SAC Unit 1.00 Total Charge: 4.10 or 4 The business information was provided to MCES by the applicant at this time. It is the City's responsibility to substantiate the business use and size at the time of the final inspection. If there is a change in use or size, a redetermination will need to be made. If you have any questions, call me at 651- 602-1378. Sincerely, t}\f Jessie Nye \.-j SAC Technician L'\\CJ Environmental Services Division J JN:kb: 070803A1 cc: S. Selby,MCES www.metrocouncil.org 390 Robert Street North • St. Paul,MN 55101-1805 • (651) 602-1000 • Fax(651) 602-1550 • TTI'(651)291-0904 An Equal Opportunity Employer Page 1 of 1 Bob Hutchins From: Bob Hutchins Sent: Friday,January 23, 2009 10:20 AM To: 'Jake Rysavy' Subject: RE: Prior Lake Fire Station Jake,The City Engineering Department has one item that is left to complete on the Fire Station#2 project: 1. As-built utility plan in electronic format. Please contactEity Engineer Nate Briese 952-447-9837 for further details. All other items for the Fire Station have been completed.Thanks ifiDtt! -we Robert D. Hutchins Building Official City of Prior Lake 4646 Dakota Street SE Prior Lake,MN 55372 952.447.9851 Fax 952.440.4263 City Email Updates.Sign up now. Original Message From: Jake Rysavy [mailto:jake.rysavy@met-con.com] Sent: Friday, January 16, 2009 9:17 AM To: Bob Hutchins Subject: Prior Lake Fire Station Bob, I was just wondering if a final CO was issued on the fire station. I think everything has been taken care of on my end. Please let me know. Thanks Jake Rysavy Project Manager Met-Con Companies, Inc. 15760 Acorn Trail Faribault, MN 55021 Ph: (507)333 1147 Fax: (507)332 8742 1/23/2009 Jake,The City Engineering Department has two items that are left to complete on the Fire Station#2 project: I. As-built utility plan 2. Rebuild heights of outlet pipes in the rain garden. Please contact Assistant City Engineer Larry Poppler 952-447-9831 for further details. All other items for the Fire Station have been completed.Thanks 4'.1.r.."") Robert D.Hutchins Building Official City of Prior Lake 4646 Dakota Street SE Prior Lake, MN 55372 952.447.9851 Fax 952.440.4263 City Email Updates.Sign up now. Original Message From: Jake Rysavy [mailto:jake.rysavy@met-con.com] Sent: Wednesday, October 01, 2008 1:13 PM To: Bob Hutchins Subject: RE: HVAC Balance Reports - PLFS Bob, I was just wondering if you had a chance to find anything out about the Temp CO, or if we need to extend that date. Let me know if you need anything from me. Thanks Jake Rysavy Project Manager Met-Con Companies, Inc. 15760 Acorn Trail Faribault, MN 55021 Ph: (507)333 1147 Fax: (507)332 8742 From: Bob Hutchins [mailto:BHutchins@CityofPRIORLAKE.com] Sent: Monday, September 29, 2008 5:02 PM To: Jake Rysavy Subject: RE: HVAC Balance Reports - PLFS Thanks `.* ' Robert D. Hutchins Building Official City of Prior Lake 4646 Dakota Street SE Prior Lake,MN 55372 952.447.985 I Fax 952.440.4263 77'- ," 6" 6" 6„ 6" 22' - 4" 26'- 2" 26'- 8" FIELD CORE DRILLING GUIDELINES 14'-8" _ 14 —s 1 . ALL CORE DRILLING IN PLANK TO BE IN THE PLANK OPEN CORE AREA ' S ONLY . OPENING SIZE NOT TO EXCEED THE OPEN PLANK CORE WIDTH , 1 8'-0 ' , 5' - 6�'4' 2 . CARE MUST BE EXERCISED NOT TO CUT STRAND IN THE PLANK WEB AREA ' S . RELOCATE OPENINGS CONSIDERING THE STRAND LOCATION INDICATED IN THE : - - - -- NJCROSS — SECTIONS . 0 I i 1 F. N. it I I 2 0 4 11 F.N. c} A 6 s I A �' I ' 2 1 STRINGER LOADS 4 I 1 3 . OPENING CLUSTERS MAY BE ARRANGED LONGITUDINALLY IN ONE PLANK CORE . I e 1 3 3 iloie3 s A FIELD CORE DRILLING THRU MORE THAN 1 / 3 OF THE WIDTH OF A PLANK IS NOT I o A 895# POINT LOAD I IfI 1 IT e PERMITTED . X , I B i A4 . PLANK OPENINGS THAT EXCEED THE WIDTH OF A PLANK CORE OR THAT CROSS A A 1 e• "� G' P� B I PLANK WEB ARE NOT TO BE CUT WITHOUT PRIOR APPROVAL FROM THE MOLIN 2 ' CIDENGINEERING DEPARTMENT . B I 1 A °P N 1 II II I � Cl) C 900# POINT LOAD 3 A 5 '� � 5 1 23r 6 " 6 " 2�'4 22'- 7Y4' 26'- 2" �4 26' - 11Y¢' 2 ' x 13�" 5�y' 1 „ 5°{" 1 • 05 {" IV3 fib" 3' CONCRETE TOPPING BY OTHERS n •O.O.O• LA m e 8" H . C. PLANK X 6" 19" 7Wan 7A' 73fe" W 8 " HOLLOWCORE FLOOR PLAN 23r SCALE : 1 /8 1 ' - 0 " -r2" x4"x1/ ' R 8" H . C. PLANK DESIGN SI LOAD 125 PSF LL . COLLATERAL 5 PSF ¶� 2'- 0" Pc T . O . PLANK EL . = 111 ' - 4 " ( TYP . ) NOR II CAST-IN 0 4' - 0" O. C. UD STEEL FRAMING, _ _ L TRACITH 600(2UPPLIIEDMINT) TOP 3" CONCRETE TOPPING 3" CONCRETE TUPPING .-- _ c _ - - a BY OTHERS _ _ - -BM: � -- BY OTHERS / INSTALLED BY OTHERS. ) - - - _ _ #3 REBAR TO 8" H .C. PLANK BE INSTALLED 23/ 8" H .C. PLANK BY OTHERS i 6 SECTION _ LOAD - CHART SCALE: 3/8" = 1 ' - 0" 8024 _ a ..J .. OO - - - " THICK X 3" WIDE x 960' RAISED STRAND LONG STEEL PLATE. (SUPPLIED AND INSTALLED DEAD WT - 57PSF BY OTHERS. ) • !a HILT] KWIK - CON 14 2"x4" x1/4' fe CAST IN SCREWS. (SUPPLIED PLANK a PLANK 0 4'-0" O.C. II AND INSTALLED BY FIELD MATERIAL SCHEDULE 4. OTHERS. ) 12" C.M . U . WALL BY OTY. DESCRIPTION OTHERS 6' C.M . U . WALL I) ,X HANGERS BY OTHERS W- BEAM BY OTHERS. (SEE LAYOUT FOR SIZE) INTALLER TO FIELD ( 1 ) 54R8 - 6 " X4" X1 /2it 4� WELD TO EMBED. VS S 0 SECTION 2 SECTION m _ SCALE: 3/8 " = 1 ' - 0" SCALE: 3/8" = 1 ' - O" it FINAL DRAWING v 3" CONCRETE TOPPING WELD ROD TO PLATE W/ 3 3" CONCRETE TOPPING BY OTHERS WELDS 0 24" O. C. STAGGER 0 BM . CL BY OTHERS WELDS (SUPPLIED AND = y„ I 2 /4" 8" H . C. PLANK ( INSTALLED BY OTHERS. ) 04 qt BRG. 8" H. C. PLANK FINAL 8 - 10 - 07 AS 8" H .C. PLANK 2 " 1 '-10" 6" N BRG. CANTILEVER wit I _ CONCRETE PRODUCTS COMPANY m \� *Y;14) ROD W/ THREADED END � FOR TENSIONING TURNBUCKLE, 415 Lilac Street, Lino Lakes, MN. 55014 s (SUPPLIED AND INSTALLED BY Office 651 - 786- 7722 • FAX 651- 786- 0229 j OTHERS. ) Drafting Fax 651 - 783-3401 • 1 -800-336-6546 REVISION DATE REV. BY W FIRE STATION # 2 z 2" x4"x1/q E CAST— IN 2"x4"x1/q 9 CAST— IN s SECTION PLANK ® 4'—o" O. C. PLANK ® 4'- 0" G. C. PRIOR LAKE , M N `` 2"x4"x %q R CAST- IN SCALE: 3/8" = 1 ' - O" PLANK CAD 4'-0" O. C. — SIGMA STUD STEEL FRAMING, SIGMA STUD STEEL FRAMING, fit WITH 611OT200� 97 (SUPPLIED MIL TOP WITH , (SUPPLIED MIL TOP 8 " H O L L O WC O R E MEZZANINE FRAMING & SECTIONS Q TRACK. (SUPPLIED AND TRACK. (SUPPLIED AND % INSTALLED BY OTHERS. ) INSTALLED BY OTHERS.) ARCHITECT I & S A ONTRACTOR MET — CON COMPANIES 3 SECTION 4 SECTION PLEASE NOTE 0 SCALE: 3/8" = 1 ' - 0 " SCALE: 3/8" = 1 '- 0 THESE SHOP DRAWINGS AND SCHEDULES SHALL1w DETERMINE ISSUE N0 . 1 07 /30 /07 THE CONTRACT� FORNCE VATH THIS MATERIAL. ALL MATERIAL ONS OF DRN . BY AS FILE JOB F07-7342—E WILL BE SCHEDULED DIRECTLY FROM THESE 0 DRAWINGS; THEREFORE THEY SHa ACCURATELY BEFORE A ROVALOISLGIVEN CHECKED CH K D BY D H C SHEET F1 OF 1 Fire Sprinkler Plan Review Date . December 26 , 2007 Owner: City Of Prior Lake : Fire Station . #2 Location : 3906 Station Place Prior Lake MN. 55372 Contractor: Brothers Fire Protection 9950 East Hwy 10 Elk River MN 55330 1 . Separate permits are required for the alarm system . 2 . The 2002 of NFPA 13 shall be the standard. 3 . All materials shall be tested and installed per the listing. 4 . All valves controlling water flow shall be monitored and secured including the PIV . 5 . It is the responsibility of the fire sprinkler contractor to flush all main and branch lines . 6 . Provide frost protection for all portions of the wet system. 7 . Field verify all head locations and obstructions . 8 . Secure all valves against tampering. All valves in public areas shall be locked 9 . Provide a water resistant system plan at the each sprinkler riser to include the following information . a. Total site plan b . All valves c . Riser locations d . Areas served by individual risers e . All main and auxiliary drains f. Location of inspector' s test g. Alarm panel location 10 . For inspections call (952) 447-9850 give the project building permit number (07 ~0751 ) 11 . Seal all penetrations in rated walls in an approved manor. 12 . Provide signage for all valves , drains and inspector' s test.