Loading...
HomeMy WebLinkAboutReview 061113 - Final Calcs CiviLDESIGN PROFESSIONALS DESIGN CALCULATIONS a FOR CANDY COVE PRIOR LADE, MINNESOTA (PROJECT # 13.144) a SUBMITTED BY.• a a �a gun 0for � aaoftip of c�a a t c i tit rah tt- gDOW'kHzcc2cd abavo is m'Sbimt o Andy C.McCoy , �Of0V coq"ft13 Omnalllm aal we t4 co minor rvn a +eoor fo ob pv- t � a006cotrwd"umals Iola 15 2013 . Al .' 1 HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THEST OF MINNESOTA. 05/15/13 DATE:_ _ MICHAEL R.JOHNSON,P.E. LICENSE NO.25943 Ovi1 Design Professionals - 8609 Lyndale Ave. 8.,9.if a 200 8loornington,W 55420 • Office 952-303-5312 . www.cdp-us,com Vis¢ CIVIL oSIGN Civil Design Professionals version 3.1.13122 Project: Candy Cove 7 7 T„ 3 Location: Prior Lake, MN �. Designer: ACM Date: 5/15/2013 K /� Section: 13.33 Design Method: NCMA 09_3rd_Ed Design Unit: ReCon SOIL PARAMETERS cp coh y Retained Soil: 38 deg 0 psf 120 pcf Foundation Soil: 38 deg 0 psf 120 pcf Leveling Pad: Crushed Stone GEOMETRY Design Height: 13.33 ft Live Load: 0 psf Wall Batter/Tilt: 3.60/0.00 deg Live Load Offset: 0.00 ft Embedment: 1.33 ft Live Load Width: 0 ft Leveling Pad Depth: 1.00 ft Dead Load: 0 psf Slope Angle: 26.6 deg Dead Load Offset: 0.0 ft Slope Length: 24.0 ft Dead Load Width: 0 ft Slope Toe Offset: 0.0 ft Leveling Pad Width: 6.00 ft Vertical 6 on Single Depth FACTORS OF SAFETY Sliding: 1.50 Overturning: 1.50 Bearing: 2.00 RESULTS FoS Sliding: 2.17(Ivlpd) FoS Overturning: 2.21 Bearing: 2435.47 FoS Bearing: 13.92 .Narhe Elev.{dpth] ka Pa . Paq's Paqd-.' P.aC PaT: FSsI(base of leveling pad) FOS OT TC 12.00[1.33] 0.280 30 0 0 0 30 100.00 32.30 24 10.67[2.66] 0.280 119 0 0 0 119 63.92 7.92 24 9.33[4.00] 0.280 268 0 0 0 268 28.99 3.65 24 8.00[5.33] 0.280 477 0 0 0 477 16.64 2.13 39 6.67[6.66] 0.319 850 0 0 0 850 10.47 3.39 39 5.33[8.00] 0.319 1224 0 0 0 1224 7.55 2.55 39 4.00[9.33] 0.319 1666 0 0 0 1666 5.76 2.01 60 2.67[10.66] 0.319 2176 0 0 0 2176 5.00 3.10 60 1.33[12.00] 0.319 2755 0 0 0 2755 4.14 2.59 60 0.00[13.33] 0.319 3401 0 0 0 3401 2.17(3.01) 2.21 Civil Design Professionals Page 1 NILDESIGN rt` -fl. PR OFESSIONALS, r T2 ri 4 COMPOUND RESULTS f Compound stability is a global analysis(Bishop)with the failure planes originating at the top of the slope/wall and existing out through the face of the wall. For MSE walls,the resistance of the geogrid reinforcement is included in the analysis and the shear resistance of the face units is included. ID Enter Point X Enter Point.Y'; Exit PoinfX ExitPoint YCenter X Center Y , Ratlius.: FoS . 677 33.08 25.35 5.08 1.33 -202.21 271.32 340.39 3.267 678 33.08 25.35 5.08 1.33 -91.32 142.05 170.57 3.285 679 33.08 25.35 5.08 1.33 -54.25 98.83 114.13 3.308 544 30.41 25.35 5.08 1.33 -191.64 234.21 304.84 3.333 680 33.08 25.35 5.08 1.33 -35.63 77.13 86.03 3.334 712 33.08 25.35 3.50 4.00 -46.17 103.98 111.64 3.344 711 33.08 25.35 3.50 4.00 -78.76 149.15 166.84 3.345 713 33.08 25.35 3.50 4.00 -29.80 81.30 84.17 3.350 710 33.08 25.35 3.50 4.00 -176.25 284.22 332.92 3.353 545 30.41 25.35 5.08 1.33 --86-.6-9--T 123.50 1 152.80 1 3.354 GLOBAL RESULTS Global stability is a global analysis(Bishop)with the failure planes originating at the top of the slope/wall and existing out below the wall in the area infront of the structure. For WE walls,the resistance of the geogrid reinforcement is included in the analysis. The curve may go through the base of the wall and the wall shear would be included. In most cases the failure plane will pass below the structure. I I ID Enter Point X Enter Point Y " Exit Point X Exit Point Y Cent& Center X Radius ' FoS 365 27.75 25.35 -18.91 1.33 -5.33 32.27 33.79 1.652 190 22.42 23.18 -16.25 1.33 -4.07 24.91 26.54 1.656 183 22.42 23.18 -13.58 1.33 -2.60 23.81 25.02 1.665 494 30.41 25.35 -21.58 1.33 -6.72 37.44 39.05 1.670 379 27.75 25.35 -21.58 1.33 -6.74 33.52 35.44 1.671 286 25.08 24.51 -21.58 1.33 -6.97 30.48 32.60 1.681 198 22.42 23.18 -18.91 1.33 -5.54 26.05 28.10 1.685 265 25.08 24.51 -16.25 1.33 -3.51 27.05 28.70 1.691 596 33.08 25.35 -16.25 1.33 -3.39 37.59 38.47 1.694 354 27.75 25.35 -16.25 1.33 -3.29 29.91 31.37 1 1.695 Civil Design Professionals Page 2 €