HomeMy WebLinkAbout4C Andren Property PrePlat Report
Phone 952.447.9800 / Fax 952.447.4245 / www.cityofpriorlake.com
4646 Dakota Street SE
Prior Lake, MN 55372
PLANNING COMMISSION AGENDA REPORT
MEETING DATE: JUNE 20, 2016
AGENDA #: 4B
PREPARED BY: CASEY MCCABE, COMMUNITY DEVELOPMENT SPECIALIST
AGENDA ITEM:
CONSIDER RECOMMENDING APPROVAL OF THE ANDREN PROPERTY
PRELIMINARY PLAT AND CONSIDER APPROVAL OF A MINIMUM
CORNER LOT SIZE VARIANCE
DISCUSSION: Introduction
Hemlock Holdings LLC has applied for approval of a Preliminary Plat, which is
currently referred to as the Andren Property and will be renamed prior to City
Council review of the Preliminary Plat. The applicant has also requested
approval of a variance from the minimum corner lot area requirements on Lot
22 of the proposed development.
The subject property is proposed to be developed as a 22-lot, low density
residential subdivision. The development site is approximately 8.58 acres and
is located south of Carriage Hills Parkway NE, north of Beach Street NE and
east of Bluebird Trail NE.
Current Circumstances
The following paragraphs outline the physical characteristics of the existing site,
the Comprehensive Plan and zoning designations and a description of some of
the site specifics.
The applicant’s request for recommended approval of the preliminary plat and
approval of a minimum corner lot size variance are further evaluated as follows:
Preliminary Plat:
Subsection 1002.200 regulates the subdivision of land; the preliminary plat
shows the proposed layout of the subdivision for preliminary approval. The plat
is further evaluated as follows:
a) Land area and characteristics: The development site area consists of 8.58
acres. In addition, the applicant is proposing a land swap with the City of
Prior Lake. The applicant would exchange 19,449 SF of land to the west
and north of the existing stormwater pond to the City of Prior Lake and
expand the pond area in exchange for 5,158 SF of current pond area, owned
by the City of Prior Lake, to be included in the development. After the
property exchange, the total development area will be approximately 8.25
acres.
The developable land area is 8.58 acres and the net developable area is
8.25 acres (subtracting area for storm ponds and including additional City
property identified for a land exchange). The property is largely wooded and
fairly sloped with elevations ranging from 924’ MSL along the southern
property line 972’ MSL at the southern terminus of Dove Court NE. Further
information on woodland preservation is provided below in the “tree
preservation” section of this report.
b) Zoning: The site is presently zoned R-1 Low Density Residential.
c) 2030 Comprehensive Plan Designation: This property is designated for Low
Density Residential uses on the 2030 Comprehensive Plan Land Use Map.
d) Surrounding land uses: land uses surrounding this proposed site include;
north – existing single family residential housing; south – existing single
family residential housing; west – existing single family residential housing;
and east – existing single family residential housing and vacant lots guided
for low density residential development.
e) Access: Access to the site is available from the north via Dove Court NE
and Raven Court NE and from the west via Hemlock Circle NE.
f) Housing density: The total development area, including the land exchange
area and subtracting the ponding area, is 8.25 acres. Using 22 total housing
units and 8.25 net acres, the housing density is 2.67 dwelling units per acre.
The density for new development in the R-1 Use District is 2.0 – 4.0 dwelling
units per acre.
g) Housing types: The proposed subdivision includes 22 single family
detached units.
h) Lots: The required minimum lot size in the R-1 Use District is 12,000 square
feet with a minimum lot width of 86 feet. The lot sizes range in size from
12,019 square feet to 19,205 square feet. Front and rear yard setbacks are
25-feet; side yard setbacks are 10-feet. A variance is being requested for
Lot 22, as further evaluated below under the “variance” section of this report.
i) Outlots: The final plat will dedicate an outlot(s) for additional stormwater
ponding area to the north and west of the current stormwater pond.
j) Streets: Right-of-way for local streets is being dedicated with this proposed
plat, including a local street that extends Hemlock Circle NE easterly, and
an extension of Dove Court NE and Raven Court NE southerly to Hemlock
Circle NE. Local street right-of-way widths of 50 feet are being dedicated.
k) Sidewalks and trails: No sidewalks or trails are proposed in this subdivision.
l) Public park: Parkland dedication will be satisfied through a cash-in-lieu
payment to the City Park Fund at the time of Final Plat approval.
m) Wetlands: There are no wetlands located on this site.
n) Stormwater management: One large stormwater management area is
located southeast of this subdivision. The applicant is proposing to
accomplish ponding requirements by expanding the existing pond located
on City of Prior Lake property to the southeast of the development property.
The majority of the existing site flows south to this existing stormwater pond.
The existing pond is located on a city parcel and discharges directly to Prior
Lake. This pond collects runoff not only from this site but also adjacent
residential areas to the south and west. Further comments are provided in
a staff memorandum attached to this report (Attachment 4).
o) Public infrastructure/utilities: This proposed subdivision can be adequately
served by municipal sanitary sewer and water. The Engineering
Department has expressed initial concerns related to easement widths and
sanitary sewer depth; however, the Engineering Department will continue
working with the applicant to address their concerns. Further comments are
provided in a staff memorandum attached to this report (Attachment 4).
p) Tree preservation: A total of pver 13,000 caliper inches for significant trees
exist on the site. In accordance with City Ordinance, significant trees may
be removed without any required replacement within the width of required
easements for public streets, utilities and storm water ponding areas. In
areas outside of the exempted areas, up to 35% of the total dbh (diameter
at breast height) inches of all significant trees may be removed without
replacement or restitution. Replacement of removed trees in excess of
these allowable percentages are to be replaced at a ratio of ½ caliper inches
per 1 caliper inch removed. The development will be required to replace
1,276.75 caliper inches of trees as a result of this development.
The applicant has discussed alternatives for replacement with city staff due
to the challenges of replacing trees on the development property. The
applicant feels the best option may be to utilize a combination of the
following items which are available to address this important tree
replacement objective; they are listed in order of priority:
1. Provide larger replacement trees using larger caliper inch trees for
replacement.
2. Provide future home owners of the proposed lots a tree planting
allowance, to be used by the homeowner to plant trees after the home
is constructed (probably set up to last from 2-3 years).
3. Provide an alternative reforestation plan for the city owned parcel
located in the southeasterly portion of the project.
4. Provide an escrow fund to the City Parks Fund for future tree planting
and tree maintenance projects on city owned property.
Approval of a tree preservation plan is required at the time of the preliminary
plat consideration by the City Council.
q) Shoreland: This property is located within the Shoreland District of Lower
Prior Lake and therefore will be regulated by the Shoreland Ordinance
including impervious surface limitations. All lots must meet the 30%
maximum impervious surface requirement when submitting building plans.
Variance:
The applicant is requesting a variance from the minimum corner lot area
requirement on Lot 22. Subsection 1004.302 of the Subdivision Code states,
“Corner lots for residential use shall exceed the minimum width and area
requirements in the Zoning Use District by twenty percent (20%) to permit
appropriate building setback from both streets as required in the Zoning
Ordinance.” In this case the applicant is requesting a variance from the
requirement of a 14,400 square foot corner lot to allow Lot 22 to be 12,019
square feet. Approval of the variance would allow the applicant to plat a larger
parcel on Lot 20 (14,268 SF) in order to preserve additional trees between Lot
20 and the neighboring home site which has a side entry facing Lot 20.
Subsection 1108.406 of the Zoning Ordinance identifies five criteria for
reviewing and approving variances to provisions of the Zoning Ordinance as
follows:
1. There are practical difficulties in complying with the strict terms of this
Ordinance; the property owner proposes to use the property in a reasonable
manner not permitted by the Zoning Ordinance. Economic considerations
alone do not constitute practical difficulties.
Response: In order to preserve natural features on Lot 20, the applicant is
requesting a variance form the minimum corner lot area requirement for Lot
22 and is proposing to increase the size of Lot 20. The property owner is
proposing to use the property in a reasonable manner and failure to grant a
variance will likely result in additional tree removal.
2. The granting of the variance is in harmony with the general purposes and
intent of the City Subdivision and Zoning Ordinances and the
Comprehensive Plan.
Response: In general, the minimum corner lot area requirement is intended
to provide appropriate building setbacks from both streets. The applicant
has indicated, even with a lesser lot area, the development of Lot 22 will
comply with the front yard setback requirement of 25-feet from both streets.
The 2030 Comprehensive Plan supports flexibility in order to achieve public
good, such as the preservations of trees.
3. The practical difficulty is due to circumstances unique to the property and
not resulting from actions of the owners of the property and is not a mere
convenience to the property owner and applicant.
Response: This property is largely wooded and the trees on Lot 20 are
worthy of preservation for the benefit of the surrounding neighborhood.
Without the variance the additional trees would be eliminated from the
property.
4. The granting of the variance will not alter the essential character of the
neighborhood or be detrimental to the health and safety of the public
welfare.
Response: The surrounding areas includes similar low density single family
housing and therefore the granting of a variance will not alter the essential
character of the neighborhood.
5. The granting of the variance will not result in allowing any use of the property
that is not permitted in the zoning district where the subject property is
located.
Response: The granting of the variance will not result in allowing any use
of the property that is not permitted in the zoning district. The proposed land
use of a single family housing is allowed in this use district.
Conclusion
Hemlock Holdings, LLC is proposing a single-family housing development that
is in compliance with the amended 2030 Comprehensive Plan and provides
housing types at a density that meets the R-1 Use District standards. The
proposed variance related to minimum corner lot area requirement is addressed
previously in this report under the five criteria for granting variances.
As noted in the attached staff memorandums from the Community
Development, Engineering and Public Works Departments, the applicant must
refine the plans to assure compliance with the Public Works Design Manual
requirements and City Zoning Ordinance. It does not appear that these
comments will drastically alter the design of the plat. Therefore, City staff
recommends approval of the Preliminary Plat subject to the following conditions:
a) The applicant shall obtain the required permits from other state or local
agencies prior to any work on the site.
b) The applicant shall revise the plans in accordance with the requirements
contained in the memorandum from the Engineering/Public Works
Department dated June 7, 2016.
c) The applicant shall revise the plans in accordance with the requirements
contained in the memorandum from the Community Development
Department dated June 16, 2016.
ISSUES: The applicant must refine the plans to assure compliance with the Public Works
Design Manual and City of Prior Lake Zoning Ordinance and Subdivision Code
requirements.
ALTERNATIVES: The Planning Commission has the following alternatives:
1. Motion and a second to recommend approval of the Preliminary Plat for the
Andren Property subject to the listed conditions, or others that may be
added or modified by the Commission.
2. Motion and a second to approve a Resolution approving a variance to allow
a corner lot area less than the required minimum 14,400 square foot lot area
requirement for a corner lot in the R-1, Zoning Use District.
3. Motion and a second to recommend denial of the preliminary plat request
based upon findings of fact.
4. Motion and a second to deny the minimum corner lot size variance request
based upon findings of fact.
5. Motion and a second to table one or both of these items to a future Planning
Commission meeting and provide the applicant with direction on the issues
that have been discussed.
RECOMMENDED
MOTION:
Alternatives #1 and #2
ATTACHMENTS: 1. Location Map
2. Development Plans dated 5/17/2016
3. Community Development Department Memorandum dated 6/16/2016
4. Engineering/Public Works Department Memorandum dated 6/7/2016
1
4646 Dakota Street SE
Prior Lake, MN 55372
RESOLUTION 16-xxPC
A RESOLUTION APPROVING A VARIANCE FROM THE MINIMUM CORNER LOT AREA
REQUIREMENT ON A PROPERTY LOCATED WITHIN THE R1-SD (LOW DENSITY
SHORELAND RESIDENTIAL) ZONING DISTRICT
Motion By: Second By:
WHEREAS,
WHEREAS,
The Prior Lake Planning Commission, acting as the Board of Adjustment, conducted
a public hearing on June 20, 2016, to consider a request from Hemlock Holdings
LLC to approve a variance from the minimum area requirement for a corner lot in the
R-1 Zoning Use District; and
The property is described as Lot 22, “Andren Property” (final plat to be named later)
(PID 25-926-018-0); and
WHEREAS, Notice of the public hearing on said variance request was duly published in
accordance with the applicable Prior Lake Ordinances; and
WHEREAS, The Planning Commission proceeded to hear all persons interested in this variance
request, and persons interested were afforded the opportunity to present their views
and objections related to the variance request; and
WHEREAS, The Planning Commission has reviewed the application for the variance as
contained in Case #DEV16-000005 and held a hearing thereon on June 20, 2016;
and
WHEREAS, The Planning Commission has considered the effect of the proposed variance upon
the health, safety, and welfare of the community and compliance with the
Comprehensive Plan.
NOW THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF PRIOR LAKE,
MINNESOTA as follows:
1. The recitals set forth above are incorporated herein.
2. The Planning Commission hereby adopts the following findings:
a. There are practical difficulties in complying with the strict terms of this
Ordinance; the property owner proposes to use the property in a reasonable
manner not permitted by the Zoning Ordinance. Economic considerations alone
do not constitute practical difficulties.
In order to preserve natural features on Lot 20, the applicant is requesting a variance
form the minimum corner lot area requirement for Lot 22 and is proposing to increase
the size of Lot 20. The property owner is proposing to use the property in a reasonable
manner and failure to grant a variance will likely result in additional tree removal.
.
2
b. The granting of the variance is in harmony with the general purposes and intent
of the City Subdivision and Zoning Ordinances and the Comprehensive Plan.
In general, the minimum corner lot area requirement is intended to provide appropriate
building setbacks from both streets. The applicant has indicated, even with a lesser
lot area, the development of Lot 22 will comply with the front yard setback requirement
of 25-feet from both streets. The 2030 Comprehensive Plan supports flexibility in order
to achieve public good, such as the preservations of trees.
c. The practical difficulty is due to circumstances unique to the property and not
resulting from actions of the owners of the property and is not a mere
convenience to the property owner and applicant.
This property is largely wooded and the trees on Lot 20 are worthy of preservation for
the benefit of the surrounding neighborhood. Without the variance the additional trees
would be eliminated from the property.
d. The granting of the variance will not alter the essential character of the
neighborhood or be detrimental to the health and safety of the public welfare.
The surrounding areas include low density single family housing and therefore the
granting of a variance will not alter the essential character of the neighborhood.
e. The granting of the variance will not result in allowing any use of the property
that is not permitted in the zoning district where the subject property is located.
The granting of the variance will not result in allowing any use of the property that is
not permitted in the zoning district. The proposed land use of a single family housing
is allowed in this use district.
3. Based upon the findings set forth herein, the Planning Commission hereby approves the
following variance from the required minimum corner lot area requirement:
a. A variance to allow a corner lot area, shown as Lot 22, less than the required minimum
14,400 square foot lot area requirement in the R-1 (Low Density Residential) Zoning
Use District.
4. The variance is subject to the following conditions of approval:
a. The variance resolution shall be recorded at Scott County following approval of the
final plat.
b. The variance is subject to the approval of the final plat, currently referred to as Andren
Property, which will be renamed prior to final plat approval.
PASSED AND ADOPTED THIS 20th DAY OF JUNE, 2016.
_______________________________ Bryan Fleming,
Commission Chair
ATTEST: _________________________________
Dan Rogness,
Community & Economic Development Director
VOTE Fleming Larson Peterson Kallberg Tieman
Aye ☐ ☐ ☐ ☐ ☐
Nay ☐ ☐ ☐ ☐ ☐
Absent ☐ ☐ ☐ ☐ ☐
Abstain ☐ ☐ ☐ ☐ ☐
LOWER PRIOR LAKE
GD
(904)
B E A C H S T N E
C A R R I A G E H I L L S P K W Y N E
R O S E W O O D R D N E
Lower Prior Lake
Ü
Andren Preliminary PlatLocation Map
LOWER PR IOR LAK E
GD
(904)
140TH ST NE
1 5 0 T H S T S E
E A G L E C R E E K A V N E
Lower Prior Lake
SUBJECTPROPERTY
SUBJECTPROPERTY
Phone 952.447.9800 / Fax 952.447.4245 / www.cityofpriorlake.com
Memo
The Community & Economic Development Department has reviewed the Preliminary Plat for the subject
project with a plan date of 5-17-16 and we have the following comments:
General
1. Development fees – The following development fees are to be collected at the time of final plat
approval: Park Dedication ($3,750 per unit), Trunk Water ($6,692/net acre), Trunk Sanitary
Sewer ($3,344/net acre), Trunk Storm Sewer ($3,069/net acre), Street Oversize ($5,412/net
acre), $9,000 Water Connection Charge, $9,000 Sanitary Sewer Connection Charge, and a 4%
administrative fee and 5% construction observation fee based on the total estimated construction
costs (which include grading, landscaping, and public utility connections).
2. Submit along with future final plat application provide City with draft warranty deed for outlots to
be dedicated to the City according to Ordinance 1004.604. A recorded copy of the deed shall be
delivered to the City after recording of the final plat.
3. If possible, provide any house model examples for future public meetings.
4. Identify preliminary plat name prior to City Council approval.
5. The City has been advised that an adjacent property owner has a private access easement
across a portion of the property. The City requests that the applicant provide more details to the
status of this easement prior to approval of the preliminary plat.
Preliminary Plat
1. Lots 1 and 3 do not currently meet the minimum lot width requirement of 86 feet. These lots will
be required to meet the 86-foot width requirement prior to City Council approval of the preliminary
plat.
2. Identify new suffix for Hemlock Circle (such as Street or Avenue).
3. Provide NE street directional on street names (Such as Dove Court NE, this is in Northeast
quadrant of City)
4. The final plat proposes to dedicate an outlot(s) for additional stormwater ponding area to the north
and west of the current stormwater pond. Also the developer requests a portion of the existing City
property to be added to Lots 3, 4, and 5. Additional land transfer information shall be necessary
between the City and Developer in the Development Agreement.
Tree Preservation Plan/Landscape Plan
5. Approval of a tree preservation plan is required prior to the City Council providing preliminary plat
approval. The Developer has identified various options to meet the tree preservation requirement.
A consideration to increase size of replacement trees to 6” caliper inches or larger would be
recommended. Another consideration would be to provide monetary funds for future residents of
the plat to use for tree installation on the lots. Proposed plantings in easements and on outlots are
subject to City Public Works approval due to necessary maintenance requirements.
Date: June 16, 2016
To: Terry Forbord, Roger Humphrey
From: Community Development Department
Subject: Andren Property Preliminary Plat
City Project #DEV1600005
Phone 952.447.9800 / Fax 952.447.4245 / www.cityofpriorlake.com
Memo
Date: June 7, 2016
To: Community Development and Natural Resources Department
From: Engineering Department – Larry Poppler, City Engineer
Public Works / Natural Resources Department – Pete Young, Water
Resources Engineer
Subject: Andren Property (DEV16-000005)
The Engineering Department and Public Works/Natural Resources Department ha ve reviewed the
preliminary plat for the subject project with a draft plan date of May 16, 2016 and we have the
following comments. Comments highlighted in bold text are of particular concern:
General
1. The final plat plans should follow the requirements of the City’s Public Works Design
Manual (PWDM).
2. Permits from the Met Council, Minnesota Pollution Control Agency, and Department of
Health are needed.
3. Show approximate location of all existing private utilities and public utilities (sanitary
sewer and watermain in easement). Show existing easement for corresponding utilities.
4. Benchmark information and City Project #DEV16-000005 should be shown on all plan
sheets.
5. All plans should be drafted according to the City of Prior Lake layer system. A digital
copy of the plans in pdf o r tif format is required prior to construction. All drawings should
use the Scott County Coordinate System.
6. Provide note on the plans stating that working hours are from 7 am to 7 pm Monday through
Friday and 8 am to 5 pm Saturday.
7. Show grading at least 200ft outside of project area.
8. Provide survey sheet that includes all spot elevations shot for this project. Include datum
information on the sheet.
9. Plat: City property will need to be vacated within the ponding area and associated outlots
provided. The triangular area to the west, if not needed for ponding, could be added to
Lots 2-3.
Grading
1. Retaining walls over four feet in height or have more than two tiers shall be designed by a
MN registered professional engineer, need a building permit, and have a fence constructed.
Walls will need to be located on private property unless prior approval from City Engineer
is given.
2. Provide emergency overflow routes, highest point along EOF, and EOF drainage flow
arrows for all roadway low points.
3. Home pads must be graded to have at least 10’ back yard area with slope less than 10:1.
Numerous lots (Ex. Lot 8) shows proposed swales adjacent to/draining to building pads.
4. Drainage easements will be required where drainage from one lot continues into an
adjacent lot. This includes all drainage swales in the backyards as well as front yards.
5. Any backyard drainage paths must be sodded and protected at the conclusion of grading
activities. Provide notes indicating that this protection is needed and labeled on the plans.
6. Although minimization of grading is proposed for area behind Lots 13 -19, will this create
areas of slow drainage? Backyard drainage swale exceeding 300 feet require storm sewer
piping, please review area for Lot 13-19. Additional easement will be required to cover
entire drainage swale.
7. Provide additional easements for drainage swale s for Lot 21-22 and Lot 8-11.
8. Show lot corner elevations.
9. Tree preservation area will require tree protection fencing and/or silt fence.
10. Show slopes for maintained areas at no more than 4:1, unmaintained at 3:1.
11. Show double row of silt fence for areas that drain to pond.
12. Show outlet elevation, emergency overflow elevation, NWL and HWL for ponds and
OHWL for water bodies on the grading plan.
13. For lots draining to side yards, provide breakpoint (highpoint) to direct stormwater towards
desired areas.
14. Show driveways and provide driveway slopes on the grading plan. Driveway grades shall
be between 2-10%.
15. Revise note on Sheet C3.01 regarding City of Chanhassen inspections.
16. Provide ghost platting for the property to the east to show how this area could potential
develop (grades, street alignment, utilities).
Utilities
1. A detail review will take place once final plat (plan and profile) has been submitted.
Below are general layout comments regarding the utility plans that were submitted with
the preliminary plat.
2. Easement width for sanitary sewer pipe along Lot 7 needs to be 2 times the depth.
3. Sewer service connections into structures are not allowed, provide service wye.
Minimize/eliminate bends for sewer service pipes by extending mainline pipe.
4. Deep sanitary sewer is proposed, please evaluate if depth can be reduced .
5. Storm sewers between Lots 4-5 and Lots 6-7 will require a minimum easement of 20’ in
width. The pipe alignment shall be centered within the easement.
6. Please provide calculations for storm sewer sizing.
Streets
1. A detail review will take place once final plat (plan and profile) has been submitted.
Below are general layout comments regarding the street plans that were submit ted with
the preliminary plat.
2. Provide geotechnical analysis report for soil borings in the project area. Show s oil boring
locations on grading plan sheets.
3. Dead end street proposed for future extension shall require barricades per detail plate
#613 and sign that reads “Future Road Extension”.
4. Proposed street lights will need to meet the City’s spacing guidelines. Please show
existing street lights on the plans.
5. Provide street sheet plan.
6. Please evaluate shifting of low point towards the east. Shifting may help with storm
sewer alignment and sanitary sewer depth.
Hydrology and Stormwater Management
1. The proposed pond poses a number of challenges that should be evaluated and
addressed.
a. The pond limits extends onto private property. Please review the layout and
evaluate fitting the pond layout within the public property. This will also
eliminate structures located within private property and storm sewer pipes
crossing private property.
b. Due to maintenance concerns, retaining walls within public property shall be
eliminated to the extent possible. Revision of pond may help in either
minimizing or eliminating retaining walls.
c. Retaining walls are both located in private and public property. Ownership
and maintenance of these walls will be an issue in the future.
d. A 10’ wide bench is required below the NWL of the pond, with a maximum
slope of 10:1. Bench will only be required fo r the areas of the pond within the
project construction limits.
e. Provide additional information for ponds (NWL, HWL, OHWL, EOF and
route) to ensure house pads and opening meet requirements.
2. The City recently updated the hydrology section of the PWDM. Please update the
drainage report to ensure that that the project will meet the following requirements:
a. Rate Control: NOAA Atlas 14 precipitation depths resulting from the 2-, 10- and
100-year, 24-hour storm events (NRCS MSE3 rainfall distribution) shall be
modeled for existing and proposed conditions. Discharge rates for the 2-, 10-, and
100-year, 24-hour storm events existing before the proposed development,
redevelopment, or change in use shall not be increased.
b. Volume Control: For new development projects, site runoff shall have no net
increase from pre-project conditions (on an annual average basis) of:
Stormwater discharge volume
Stormwater discharge of Total Suspended Solids (TSS)
Stormwater discharge of Total Phosphorus (TP)
This is a requirement of the State MS4 permit. For new development, one of the
five options listed in the MPCA’s publication wq-strm4-59e may be used to meet
the volume control requirements. Link:
https://www.pca.state.mn.us/sites/default/files/wq-strm4-59e.pdf.
3. All sites must consider the use of curve number reductions to meet a portion of the
volume control requirements. Methods include tree plantings, native grass buffers,
impervious disconnection, soil amendments, and others. Credits are given for each
method on an area basis. Please review Section Four of Part III (Hydrology Rules) of the
PWDM for more information.
4. Requirements and recommendations of the Minnesota Stormwater Manual shall be
followed for all BMPs proposed to meet volume control requirements. For sites relying
on infiltration, tests are required to provide a base infiltration rate for the surrounding
soils. Infiltration tests must be conducted at the location and elevation of the proposed
infiltration system.
5. P8 model includes precipitation data that appears to be at ypical for this area (including
precipitation total of 50.4 inches for a 2-year model run). The 1971-1972 period may not
include representative rainfall events. Please provide more information on the selection of
P8 model input data.
6. Show or define access routes for maintenance purposes to all inlets and outlets at ponding
areas (maximum 8% grade, maximum 2% cross slope, minimum of 10’ wide).
SWPPP
1. NPDES construction site permit will be required for this project. Please submit a SWPPP
that meets all current NPDES requirements. The City must review and approve the
SWPPP prior to grading permit approval.
2. The following City standards are in addition to standard SWPPP requirements:
a. Provide a note stating that perimeter/downslope sediment control BMPs will be
installed by the contractor and inspected by the City prior to site work
commencing.
b. Install erosion control BMPs on slopes greater or equal to 3:1 immediately after
finished grading.
c. Drainage areas over 5 acres must have a temporary sediment basin. Design should
follow NPDES SWPPP requirements.
Wetlands
1. The WCA Notice of Decision (NOD) was issued for this property on 5/24/16. No wetlands
were identified at the site. However, as noted in the LGU Findings and Conclusions (page
1 of the NOD), the City will require a separate No Loss application for any work within
the existing stormwater pond.