Loading...
HomeMy WebLinkAbout5D Agenda Report for Scoreboard Phone 952.447.9800 / Fax 952.447.4245 / www.cityofpriorlake.com 4646 Dakota Street SE Prior Lake, MN 55372 CITY COUNCIL AGENDA REPORT MEETING DATE: November 4, 2019 AGENDA #: 5D PREPARED BY: ANGIE BARSTAD, RECREATION MANAGER PRESENTED BY: ANDY BROTZLER, PUBLIC WORKS DIRECTOR/CITY ENGINEER AGENDA ITEM: P.L.A.Y. Electronic Scoreboard Installation at Ponds Athletic Complex GOAL AREA AND OBJECTIVE: High-Value City Services 5. Grow collaborations to provide efficient and cost-effective services to the community. DISCUSSION: Introduction The purpose of this agenda item is to consider approval of an agreement for the donation, installation and maintenance of scoreboards between the City of Prior Lake and P.L.A.Y. at Ponds baseball fields 1 through 6. During the summer of this year, Randy Geister, Director of P.L.A.Y., informed Greg Skluzacek, Parks Foreman, that P.L.A.Y. would like to purchase and install electronic scoreboards at the Ponds Athletic Complex for baseball fields 1 through 6. Staff and P.L.A.Y. have worked together to develop expectations for the installation, maintenance and use of the scoreboards. History The P.L.A.Y. Executive Board has given approval of funding of electronic scoreboards at Ponds. The scoreboards will be available for all users. These score boards will help keep the athletic complex updated and competitive with surrounding community fields. Current Circumstances Staff has worked with the City Attorney to develop the attached agreement. Parts of this project will need to get prepped this fall, such as the electrical and possibly the brackets, in order for the boards to be placed, with final set up in the spring. The goal is for the scoreboards to be available for the first weekend in May softball tournament. FINANCIAL IMPACT: P.L.A.Y. will fund the entire project and be responsible for all maintenance on the scoreboards. ALTERNATIVES: 1. Motion and second as part of the consent to adopt the resolution to approve the agreement between the City of Prior Lake and P.L.A.Y. 2. Motion and second to remove the item from the consent agenda for additional discussion. RECOMMENDED MOTION: Alternative #1 4646 Dakota Street SE Prior Lake, MN 55372 RESOLUTION 19-128 A RESOLUTION APPROVING THE AGREEMENT FOR THE DONATION, INSTALLATION AND MAINTENANCE OF SCOREBOARDS BETWEEN THE CITY OF PRIOR LAKE AND P.L.A.Y. AT THE PONDS ATHLETIC COMPLEX Motion By: Second By: WHEREAS, Staff and P.L.A.Y. have worked together to develop the agreement for the donation, installation, maintenance and use of the scoreboards at Ponds Athletic Complex, baseball fields 1 through 6. WHEREAS, Scoreboards will be donated, installed and maintained by P.L.A.Y.; and WHEREAS, Scoreboards will be available for all users. NOW THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF PRIOR LAKE, MINNESOTA as follows: 1. The recitals set forth above are incorporated herein. 2. P.L.A.Y. will start parts of the project this fall, which includes electrical and possibly the brackets, in order for the boards to be placed, with final set up, in the spring. The goal is for the socreboards to be available for the first weekend in May for the softball tournament. Passed and adopted by the Prior Lake City Council this 4th day of November 2019. VOTE Briggs Thompson Burkart Braid Erickson Aye ☐ ☐ ☐ ☐ ☐ Nay ☐ ☐ ☐ ☐ ☐ Abstain ☐ ☐ ☐ ☐ ☐ Absent ☐ ☐ ☐ ☐ ☐ ______________________________ Jason Wedel, City Manager WWW.DAKTRONICS.COM E-MAIL: SALES@DAKTRONICS.COM 201 Daktronics Drive, PO Box 5128, Brookings, SD 57006 Phone: 1-800-325-8766 or 605-692-0200 Fax: 605-697-4746 DD1734740 010818 Page 1 of 9 DISPLAY COLOR Choose from 150+ colors (from Martin Senour® paint book) at no additional cost. CONSTRUCTION Alcoa aluminum alloy 5052 for excellent corrosion resistance PRODUCT SAFETY APPROVAL ETL-listed to UL 48, tested to CSA standards, and CE-labeled OPERATING TEMPERATURES • Display: -22° to 122° Fahrenheit (-30° to 50° Celsius) • Console: 32° to 130° Fahrenheit (0° to 54° Celsius) DIGITS & INDICATORS • All digits are 18" (457 mm) high. All indicators are 2" (51 mm) in diameter. • Select red, amber, or white LED digits and indicators. • Scoreboard features robust weather-sealed digits (see DD2495646). • Digits may be dimmed for night viewing. CAPTIONS • HOME, GUEST, INNING and TIME captions are 9" (229 mm) high. All other captions are 6" (152 mm) high. • Standard captions are vinyl, applied to the display face. DAKTRONICS BA-2718 PRODUCT SPECIFICATIONS GUEST HOME INNING BALL STRIKE OUT PITCH COUNT AT BAT H/E TIME Choose one of four vinyl captions (Optional changeable caption panels also offered) This outdoor LED baseball/softball scoreboard displays HOME and GUEST scores to 99, INNING to 9 and indicates BALL to three, STRIKE to two and OUT to two. Scoreboard shows TIME to 99, but can display different information depending on the selected control console (see chart on page 2). Scoreboard shown with optional striping and amber PanaView® digits. DIMENSIONS UNCRATED WEIGHT POWER (120 VAC)* 5'-0" H x 10'-0" W x 8" D (1.52 m, 3.05 m, 203 mm)115 lb (52 kg) Red/Amber Digits 100 Watts, 0.9 Amp White Digits 210 Watts, 1.8 Amps *Scoreboard requires a dedicated circuit. Models with 240 VAC power at half the indicated amperage are also offered (International Use Only). WWW.DAKTRONICS.COM E-MAIL: SALES@DAKTRONICS.COM All Sport® and PanaView® are trademarks of Daktronics, Inc. Martin Senour® is a registered trademark of its owner. DD1734740 010818 Page 2 of 9 Copyright © 2010-2018 Daktronics, Inc. CONTROL CONSOLES CONTROL OPTIONS All Sport® 1600* (see SL-04352) *May be upgraded to All Sport 5000 (see SL-03991) Wired (standard): One-pair shielded cable of 22 AWG minimum is required. A cover plate with mounted connector and standard 2" x 4" x 2" (51 mm x 102 mm x 51 mm) outlet box is provided. Connector mates with signal cable from control console. Wireless (optional): 2.4 GHz spread spectrum radio features 64 non-interfering channels and 8 broadcast groups (see SL-04370). RC-200 (see DD3715714) Optional wireless handheld controller features 2.4 GHz spread spectrum radio with 64 non-interfering channels and 8-10 hours of operation via internal rechargeable battery. DAKTRONICS BA-2718 PRODUCT SPECIFICATIONS TIME CLOCK The two-digit clock can display hours/minutes/seconds. Clock information shifts from hours to minutes to seconds as time counts down. MOUNTING Scoreboard is typically mounted on two vertical beams or poles. Hardware to mount scoreboard on two beams is included; hardware for more beams is at additional cost. Standard mounting uses I-beam clamps. Optional mounting method using angle brackets is also offered; maximum beam width is 10" (254 mm) and maximum beam depth is 13" (330 mm). Refer to attached drawings for more information on mounting methods. SERVICE ACCESS Digit panels and electronics are serviced from the front of the scoreboard. GENERAL INFORMATION Scoreboard provides scoring capabilities for two teams. 100% solid state electronics are housed in an all aluminum cabinet. Scoreboard is shipped in one section. Scoreboard power is to be provided on a dedicated circuit to prevent loss of game information due to failure of another component on the circuit. Specifications and pricing are subject to change without notice. OPTIONS & ACCESSORIES • Scoreboard border striping • Multiple caption and striping colors (see DD2101644) • Team name caption in place of HOME • AT BAT, H/E (hit/error) or PITCH COUNT captions on changeable panels • One 1'-6.625" (473 mm) tall x 2'-8" (813 mm) wide logo/sponsor area. Copy is applied to the display face.* • Individual digit protective screens (see SL-04939) • Protective netting (see DD2690927) • Optional angle bracket mounting method • Advertising/identification panels • Decorative accents • Electronic message centers and video displays in multiple sizes * Only for scoreboard with vertical TIME, AT BAT or H/E caption ADVERTISING/IDENTIFICATION PANELS Backlit & Non-Backlit Top/Bottom: 1'-6" H x 10'-0" W (457 mm, 3.05 m) 2'-0" H x 10'-0" W (610 mm, 3.05 m) 2'-6" H x 10'-0" W (762 mm, 3.05 m) Non-Backlit Sides: 5'-0" H x 4'-0" W (1.52 m, 1.22 m) For additional non-backlit panel sizes, see SL-03761. FOR ADDITIONAL INFORMATION • Installation Specifications: DWG-1162576 (attached) >One Ad Panel: DWG-1183216 (attached) >Two Ad Panels: DWG-1183219 (attached) • Standard I-beam Mounting: DWG-1129110 (attached) • Optional Pole Mounting: DWG-1130246 (attached) • Component Locations: DWG-1126577 (attached) • Architectural Specifications: See DD1734715 INFORMATION DISPLAYED CONTROLLER AS 1600 AS 5000 RC-200 AT BAT  H/E  TIME  PITCH COUNT 1 2 1) Pitch count controlled via handheld pendant 2) Pitch count controlled via console keypad WWW.DAKTRONICS.COM E-MAIL: SALES@DAKTRONICS.COM All Sport® and PanaView® are trademarks of Daktronics, Inc. Martin Senour® is a registered trademark of its owner. DD1734740 010818 Page 3 of 9 Copyright © 2010-2018 Daktronics, Inc. GUEST HOME INNING BALLSTRIKE OUT PITCH COUNT AT BAT H/E TIME GUEST HOME INNING BALLSTRIKE OUT PITCH COUNT AT BAT H/E AT BAT GUEST HOME INNING BALL STRIKE OUT PITCH COUNT AT BAT H/E H/ E GUEST HOME INNING BALLSTRIKE OUT PITCH COUNT AT BAT H/E PITCH COUNT GUEST HOME INNING BALLSTRIKE OUT PITCH COUNT AT BAT H/E AT BAT GUEST HOME INNING BALL STRIKE OUT PITCH COUNT AT BAT H/E H/E ALTERNATE CAPTIONS & SCORING MODES DAKTRONICS BA-2718 PRODUCT SPECIFICATIONS Logo/Sponsor area with vertical TIME caption applied directly to scoreboard face Logo/Sponsor area with vertical AT BAT caption applied directly to scoreboard face Logo/Sponsor area with vertical H/E caption applied directly to scoreboard face PITCH COUNT caption applied directly to scoreboard face OR on optional changeable panel AT BAT caption applied directly to scoreboard face OR on optional changeable panel H/E caption applied directly to scoreboard face OR on optional changeable panel DRAWN:DATE: SHEET JOB NO:REV OUTDOOR SCOREBOARDS INSTALLATION 10' WIDTH SCOREBOARD INSTALLATION SPECS JROBERS 31 JAN 14 P 1538 E 10 A JROBERS 116257601 EXPOSURE B EXPOSURE C * DENOTES BUCKLING BRACE REQUIRED FOOTING DIMENSIONS = DIA. x DEPTH NOTES: 1. FOOTING AND COLUMN SIZES ARE SUGGESTIONS ONLY, PROVIDED TO ASSIST WITH ESTIMATING INSTALLATION COSTS AND ARE NOT INTENDED FOR CONSTRUCTION PURPOSES. THE DESIGN MUST BE CERTIFIED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF THE INSTALLATION BEFORE THEY CAN BE USED FOR FABRICATION OR ERECTION. 2. INTERNATIONAL BUILDING CODE 2012 USED IN DESIGN OF COLUMNS AND FOOTINGS WITH, IMPORTANCE FACTOR=1, Kzt=1.0, Kd=0.85, G=0.85. SEISMIC DESIGN WAS NOT CONSIDERED. 3. FOOTING DIMENSIONS ARE BASED ON ASSUMED SOIL CLASS 4 (ALLOWABLE LATERAL BEARING PRESSURE OF 150 psf). 4. STRUCTURAL STEEL IS GRADE A992 (50 ksi) STEEL. CONCRETE SHALL HAVE A MINNIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 psi. 5. THE AVERAGE DISPLAY WEIGHT FOR A LAYOUT CAN NOT EXCEED 8 PSF. 6. DAKTRONICS INC. IS NOT RESPONSIBLE FOR STRUCTURES DESIGNED AND INSTALLED BY OTHERS. 7. REFER TO DAKTRONICS DRAWING 1407-E07B-299257 FOR DETAILS OF DISPLAY MOUNTING TO COLUMNS. 8. LOCAL BUILDING OFFICIALS SHOULD BE CONTACTED TO DETERMINE THE WIND SPEED AND EXPOSURE CATEGORY FOR THE PROPOSED SIGN LOCATION. THE EXPOSURE CATEGORIES B AND C ARE DEFINED AS: EXPOSURE B - URBAN AND SUBURBAN AREAS, WOODED AREAS, OR OTHER TERRAIN WITH NUMEROUS CLOSELY SPACED OBSTRUCTIONS HAVING THE SIZE OF SINGLE-FAMILY DWELLINGS OR LARGER. THESE CONDITIONS MUST PREVAIL FOR A DISTANCE FROM THE SIGN OF AT LEAST 2,600 ft OR 20 TIMES THE SIGN HEIGHT, WHICHEVER IS GREATER EXPOSURE C - OPEN TERRAIN WITH SCATTERED OBSTRUCTIONS HAVING HEIGHTS GENERALLY LESS THAN 30 FT. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY, GRASSLANDS, AND ALL WATER SURFACES IN HURRICANE PRONE REGIONS. 9. FOR SPECIFIC PRODUCT DETAILS ON WEIGHT, MOUNTING, ETC. REFER TO THE INDIVIDUAL PRODUCT SPECIFICATION SHEETS. DISPLAY HEIGHT 10'-0" FRONT VIEW REAR VIEW SIDE VIEW LAYOUT VIEW COLUMNS AND FOOTING ONLY CONCRETE DRILLED PIER FOUNDATION (FOOTING) GRADE GRADE GRADE FOOTING DIAMETER FOOTING DEPTH HEIGHT ABOVE GRADE 5-6" - 6'-6" C-C SPACING CONCRETE SLOPED AT 2% AWAY FROM COLUMNS TO AVOID WATER PONDING 0'-6" * DENOTES BUCKLING BRACE REQUIRED FOOTING DIMENSIONS = DIA. x DEPTH THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BY ANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OF DAKTRONICS, INC. COPYRIGHT 2014 DAKTRONICS, INC. DAKTRONICS, INC. AV DISPLAY HEIGHT IS MADE UP OF ANY COMBINATION OF SCOREBOARDS, AD PANELS, TRUSSES, AND MESSAGE CENTERS. DATE:REV BY: 01 27 MAR 14 JLR UPDATED CHART MEMBER SIZES PER C-C SPACINGCHANGE THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWINGARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BYANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OFDAKTRONICS, INC. OR ITS WHOLLY OWNED SUBSIDIARIES.COPYRIGHT 2016 DAKTRONICS, INC. (USA) THIRD ANGLE PROJECTION AH INCHES [MILLIMETERS] DO NOT SCALE DRAWING OUTDOOR LED SCOREBOARDSINSTALLATION SPECS; 5'X10' MODELS- 1 AD, 14' WIDE DISPLAY TTASCHN 22 JUL 14 P1192 R 10 A 1/80 MCOPL/RNEYEN 118321601 REV DATE:BY: 01 31 APR 16 KDD REMOVED MODEL NUMBERS TO MAKE DWG GENERIC THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWINGARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BYANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OFDAKTRONICS, INC. OR ITS WHOLLY OWNED SUBSIDIARIES.COPYRIGHT 2016 DAKTRONICS, INC. (USA) THIRD ANGLE PROJECTION AH INCHES [MILLIMETERS] DO NOT SCALE DRAWING OUTDOOR LED SCOREBOARDSINSTALLATION SPECS: 5'X10' MODELS- 2 ADS TTASCHN 22 JUL 14 P1192 R 10 A 1=80 MCOPL/RNEYEN 118321901 REV DATE:BY: 01 01 APR 16 KDD REMOVE MODEL NUMBERS TO MAKE DWG GENERIC REV01 DATE:8 JAN 14 ADDED ALLOWABLE TENSION AND SHEAR CAPACITY DETAILSADDED NON-BKLT AD PANEL MOUNTING DETAILS CHANGED DWG TO B SIZED. BY:JAVA DAKTRONICS, INC.THE CONCEPTS EXPRESSED AND DETAILS SHOWN ONTHIS DRAWING ARE CONFIDENTIAL AND PROPRIETARY.DO NOT REPRODUCE BY ANY MEANS WITHOUT THEEXPRESS WRITTEN CONSENT OF DAKTRONICS, INC. COPYRIGHT 2014 DAKTRONICS, INC. BROOKINGS, SD 57006 DO NOT SCALE DRAWING PROJ:OUTDOOR SCOREBOARD TITLE:I-BEAM CLAMP MOUNTING, SHEET METAL ATTACHMENT DESIGN:KSCHNABEL DRAWN:KSCHNABEL DATE:17-JUN-15 SCALE:1/8 SHEET:REV JOB NO: FUNC-TYPE-SIZE 11291101 OF 1 02 P 1753 E -10 -B REV02 DATE:17 JUN 15 CHANGED TENSION CAPACITY TO 1376 LBSADDED MININUM AND MAXIMUM FLANGE WIDTHS BY:AMP MOUNTING INSTRUCTIONS: 1. LIFT THE FIRST SECTION OF THE DISPLAY INTO POSITION AGAINST I-BEAMS. NOTE: IF THE DISPLAY IS MADE UP OF MULTIPLE SECTIONS ALWAYS INSTALL THE BOTTOM SECTION FIRST AND WORK UP.2. STARTING ON THE TOP OF THE SECTION BEING INSTALLED MARK AND DRILL 9/16" HOLES IN THE CENTER OF THE TOP FLANGE OF THE SECTION. MAKE SURE THE HOLES ARE POSITIONED AS CLOSE TO THE I-BEAM FLANGES AS POSSIBLE. 3. INSTALL ALL THE HARDWARE SHOWN PROVIDED AND TIGHTEN THE SECTION IN THE DESIRED LOCATION. 4. ONCE THE TOP OF THE SECTION IS SECURE MOVE TO THE BOTTOM OF THE SECTION AND REPEAT THE STEPS ABOVE. 5. IF THE DISPLAY IS MADE OF MULTIPLE SECTIONS REPEAT THE ENTIRE PROCEDURE ABOVE.6. ENSURE ALL 1/2" HARDWARE IS TORQUED TO THE SPECIFIED AMOUNT. STANDARD SHEETMETAL SCOREBOARD/BACKLIT AD PANEL MOUNTING METHOD ALLOWABLE CAPACITY PER EACH CLAMP: SHEAR = 160 LBSTENSION = 1376 LBS SHEAR AND TENSION LOADDIRECTION ARE AS INDICATED ON ROTATED VIEWS STANDARD NON-BACKLIT AD PANEL MOUNTING METHOD QUALIFIED FOR SECTIONS UP TO 5' IN HEIGHT USING RECOMMENDED STRUCTURE MIN FLANGE WIDTH = 3-7/8" MAX FLANGE WIDTH = 13"MIN FLANGE WIDTH = 3-7/18" MAX FLANGE WIDTH = 13" FRONT ROTATED VIEW 1/2-13 SQUARE NUT WASHER PLATE @2 MOUNTING CHANNEL 1/2" SPLIT LOCK WASHER 1/2" FLAT WASHER I-BEAM CLAMP #12-14 X 1.500" SELF DRILLING SCREW 1/2-13 X 3.500 BOLTTENSI O N SH E A R - X SHEAR-Y FRONT OF SECTION SECTIONS VERTICAL BEAM - RECOMMENDED FLANGE THICKNESS 3/16" - 3/4" IF I-BEAM FLANGE IS GREATER THAN 3/4" THICK LONGER BOLTS WILL BE REQUIRED AT THE CUSTOMER'S EXPENSE. 1/2-13 X 3.500 BOLT - BOLT THREAD MUST ENGAGE ENTIRE DEPTH OF SQUARE NUT. BOLT MUST BE TIGHTENED TO 40FT-LB TORQUE 1/2" SPLIT LOCK WASHER 1/2" FLAT WASHER I-BEAM CLAMP - ASSURE CLAMP IS TIGHTLY ENGAGED TO I-BEAM AND NUT 1/2-13 SQUARE NUT 1/8" THICK WASHER PLATE @2 - IT IS CRITICAL 2 WASHER PLATES ARE USED PER HARDWARE ASSEMBLY MOUNTING CHANNEL WITH OBROUND SLOTS - CENTER THE CHANNEL 0N THE I-BEAM AS MUCH AS POSSIBLE #12-14 X 1.500" SELF DRILLING SCREW - INSERT SCREW UNTILHEAD CONTACTS BEAM CLAMP. DO NOT STRIP OUT SCREW. TOP VIEW 1/2-13 SQUARE NUT WASHER PLATE @2 MOUNTING CHANNEL 1/2" SPLIT LOCK WASHER 1/2" FLAT WASHER I-BEAM CLAMP #12-14 X 1.500" SELF DRILLING SCREW 1/2-13 X 3.500 BOLTTENSION SHEAR - X SHEAR-Y REAR ROTATED VIEW VERTICAL BEAM - RECOMMENDED FLANGE THICKNESS 3/16" - 3/4" IF I-BEAM FLANGE IS GREATER THAN 3/4" THICK LONGER BOLTS WILL BE REQUIRED AT THE CUSTOMER'S EXPENSE. 1/2-13 X 3.500 BOLT - BOLT THREAD MUST ENGAGE ENTIRE DEPTHOF SQUARE NUT. BOLT MUST BE TIGHTENED TO 40FT-LB TORQUE 1/2" SPLIT LOCK WASHER 1/2" FLAT WASHER I-BEAM CLAMP - ASSURE CLAMP IS TIGHTLY ENGAGEDTO I-BEAM AND NUT 1/2-13 SQUARE NUT 1/8" THICK WASHER PLATE @2 - IT IS CRITICAL 2 WASHER PLATES ARE USED PER HARDWARE ASSEMBLY MOUNTING CHANNEL WITH OBROUND SLOTS - CENTER THE CHANNEL 0N THE I-BEAM AS MUCH AS POSSIBLE #12-14 X 1.500" SELF DRILLING SCREW - INSERT SCREW UNTIL HEAD CONTACTS BEAM CLAMP. DO NOT STRIP OUT SCREW. TOP VIEW FRONT OF SECTION SECTIONS THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BY ANY MEANS WITHOUT THE EXPRESSED WRITTEN CONSENT OF DAKTRONICS, INC. COPYRIGHT 2013 DAKTRONICS, INC. DAKTRONICS, INC. AV DRAWN:DATE: SHEET JOB NO:REV OUTDOOR SHEET METAL SCOREBOARDS SCOREBOARD MOUNTING KDRAGT 14 MAR 13 P 1753 E 10 A 1=8 KDRAGT 113024600 BEAM 1/2" HEX NUT 1/2" WASHER CLAMPING ANGLE 1/2" SQUARE NUT C-CHANNEL 0.750 1.USE THE MOUNTING CHANNEL TO DETERMINE WHICH HOLE COMBINATION SHOULD BE USED. BE SURE TO KEEP THE BOLT AS CLOSE TO THE BEAM AS POSSIBLE. 2.USING THE MOUNTING CHANNEL AS A TEMPLATE, DRILL 9/16" HOLES IN THE UPPER AND LOWER REAR FLANGE OF SCOREBOARDS WHERE THE SUPPORTS WILL GO. 3.PLACE SQUARE NUTS INSIDE CHANNEL AND THREAD BOLTS THROUGH. 4.LIFT SCOREBOARD INTO POSITION WITH BOLTS STILL IN PLACE. 5.PLACE MOUNTING ANGLES OVER EACH PAIR OF BOLTS AND SECURE WITH LOCK WASHERS AND HEX NUTS. 6.WHEN SCOREBOARD IS ADJUSTED TO FINAL DESIRED POSITION, TIGHTEN HEX NUTS FIRMLY. MOUNTING INSTRUCTIONS: SCOREBOARD 1/2-13 x 15" THREADED ROD BA-2718-R/A/W 3 18" = DRIVER CONNECTOR WIRED TO THAT DIGIT = DIGIT SIZE = DRIVER CONNECTOR AND SEGMENT (PIN) # WIRED TO THAT INDICATOR = DRIVER NUMBER 6B A1 FRONT VIEW 1 18" 2 18" 5 18" 3 18" 4 18" 7 18" 8 18" 6A 6B 6C 6D 6E 6F 6G OPTIONAL RADIOPRIMARY DRIVER (A1) (KNOCKOUTS FOR 1/2" CONDUIT) SIGNAL OPTION ON THIS RADIO (WIRE, FIBER, OR RADIO) OPTIONAL AT BAT, H/E, OR PITCH COUNT CAPTIONS BRN RED ORN TAN PNK BLU VIO NOTES: A1 THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWINGARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BYANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OFDAKTRONICS, INC. OR ITS WHOLLY OWNED SUBSIDIARIES.COPYRIGHT 2017 DAKTRONICS, INC. (USA) THIRD ANGLE PROJECTION AH REV DATE:BY: 01 03 MAR 15 ZSW PER EC-17119, ADDED SIGNAL OPTION NOTE ANDREMOVED DETAIL VIEWS REV DATE:BY: 02 08 MAY 17 KDD PER EC-35064, UPDATED 'TIME' CAPTION TO MATCHDWG-1125204 REV TITLE: PROJECT: INCHES [MILLIMETERS] DESIGN: SCALE: DIM UNITS:DATE:SHEET DO NOT SCALE DRAWING FUNC - TYPE - SIZE DRAWN:- JOB NO. - OUTDOOR SHEETMETAL SCOREBOARDSCOMPONENT LOCATION; BA-2718-R/A/W KDRAGT 05 FEB 13 P1753 E 10 A 1=20 KDRAGT 112657702