HomeMy WebLinkAboutBldg Permit 01-1317
CITY OF PRIOR LAKE BUILDING PERMIT,
TEMPORARY CERTIFICATE OF ZONING COMPLIANCE
AND UTILITY CONNECTION PERMIT
Date Rec' d
(Please type or print and si~ at bum>>u)
ADDRESS
I. White File I PERMIT NO.
2. Pink City
3. Yellow Applicant
15300
~E: FFE-RS
LEGAL DESCRIPTION (office use only)
LOT I4aLOCK 4- ADDITION 1i~oa.1 (ly-~ i
I
OWNERW. " I r
(Name) O,,''''S~^' ~~e.s
PIDZ5-3~n- Olo7- 0
(Phone)
(Address)
BUlLDE~ \ r . (\C
(Name) \>JoA~0~
(Contact Name) \4<At...
(A4dress)
~
~.~~.
~ (' rY"
\).jO~-,,*"
(Phone)
(Phone)
bS-I - ?6~... (662-
6Sf .-?Lr7 -75" 3<-
~v\. <..
TYPE OF WORK
ODeck
ORe-Roofing
OAlteration
o Porch
o New Construction
ON {;;::-- OLower Level Finish
OMiSC.4:{e'hJN1N9 wall
o Fireplace
OAddition
PROJECTCOST/VALUE (excluding land) $
ORe-Siding
OUtility Connection
48ao <r-
I hereby certifY that I have furnished information on this application which is to the best of my knowledge true and correct. I also certifY that I am the owner or
authorized agent for the above-mentioned property and that all construction will conform to all existing state and local laws and will proceed in accordance with
sUbmitte~nP~~I am aware the building official can revoke this permit for just cause. Furthermore, I hereby agree that the city official or a designee may
;ter uPo",..;L perty to 0 ded inspections. , I J ~ I 0 I
/ Signature Contractor's License No. Date
Permit Valuation
Permit Fee
Plan Check Fee
State Surcharge
Penalty
Plumbing Permit Fee
Mechanical Permit Fee
c~'
III.7C::; r ~. ':l:: I
72 21 $ 'I]~ fJ I
..~ ~- # .,
2-. CJ? $ ~ .-'D
$
$
$
$
$
-roTA-t-
TOTALDUE (~ I!::~ -0 I
Park Support Fee
SAC
#
#
Water Meter
Size 5/8"; 1";
Pressure Reducer
Sewer/Water Connection Fee
Water Tower Fee
#
#
Builder's Deposit
Other
Sewer & Water Permit Fee
Gas Fir~ace Permit F7
/) .~
is A n Be es Your Building Permit When Approved
I Paid
I Date
I~. Orb;.
{-Z-1l-1 , Of
1/- / if -6/
Date
$
$
$
$
$
$
$
$ i B0.0fo
- $ wJU.~ bl9
. ~. -II
\
Receipt No. '1-' r2... '\
By fU)1tJ
This is to certify that the request in the above application and accompanying documents is in accordance with the City Zoning Ordinance and may proceed as requested. This document
Whe~d" by the City Planner constitutes a temporary Certificate of Zoning compliance and allows construction to commence. Before occupancy, a Certificate of Occupancy must be
isSu~/.A~ ~1k/81
, 'f>lanning Director Date Special Conditions, if any
24 hour notice for all inspections (952) 447-9850, fax (952) 447-4245
16200 Eagle Creek Avenue Prior Lake, MN 55372
.'/.~
White - Building
Canary - Engineering
Pink - Planning
The ('enter of the l.lke ('ountry
BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST
NAME OF APPLICANT /))olJdo r-FF COJJSr
APPLICATION RECEIVED /l- 8"*01
The Building, Engineering, and Planning Departments have reviewed the building permit
application for construction activity which is proposed at:
7{ec,aJ (1~~ f
I .
AccePt~ -
Accepted With Corrections
::::::ed By: :2f4J-
Comments:
Date: II,. rrs-o(
"The issuance or granting of a permit or approval of plans, specifications and
computations shall not be construed to be a permit for, or an approval of, any violation of
any of the provisions of this code or of any other ordinance of the jurisdiction. Permits
presuming to give authority to violate or cancel the provisions of this code or other
ordinances of the jurisdiction shall not be valid."
~
White - Building
Canary - Engineering
Pink - Planning
The Ctnltr of the Lake Country
BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST
NAME OF APPLICANT
APPLICATION RECEIVED
I ,l,...,\ A } ,'7' ) / { (...
~I/; .,' l.J .-' I
/{- 8 --() I
,~- t
i .,...
j.j "
The Building, Engineering, and Planning Departments have reviewed the building permit
application for construction activity which is proposed at:
--"'\
1<'
(1.1
;, Vi:).s -/
Accepted
v
Accepted With Corrections
Denied
ReVieWe;BY: q~~
Comments:
.~z?};e".o ~ 'lIiY..iuVL\'~'Vf
Date: it I~/e l
vJdlQ~
"The issuance or granting of a permit or approval of plans, specifications and
computations shall not be construed to be a permit for, or an approval of, any violation of
any of the provisions of this code or of any other ordinance of the jurisdiction. Permits
presuming to give authority to violat9 or cancel the provisions of this code or other
ordinances of the jurisdiction shall not be valid."
'. :'7~. /;.~ Jo, _~.~ ).KJ~~:. ~?..~ft;t~~,~;f>~~~: 1''': -.-:. ~;, ,-;;...Ii","-',' ..,:":~.-., - ~.---,.., ,-~ ,.:~"t.~rji.~~t~~" .:;jIlq:t.-..~-'N-!" .;- Y"/1' ...-, ." ...., .;,.< ,(,,-~,~.t~ _,:,,:Ao("~~~t. ..,..""'r..l....v., ~'"'.''' <-:. "'-'. . , -
White - Building
Canary - Engineering
Pink - Planning
Th. C.n.., of lh. I.ab Counlry
BUILDING PERMIT APPLICATION DEPARTMENT CHECKLIST
NAME OF APPLICANT uJolJdo r..f'F CoJJs-J-
APPLICATION RECEIVED 1(- 8'--0 J
The Building, Engineering, and Planning Departments have reviewed the building permit
application for construction activity which is proposed at:
7{eClaJ (1~ves I
, - ,
Accepted
x
Accepted With Corrections
Denied
Reviewed By:
IVA.B
Date: /1-/..5-01
Comments: See Reverse Side for Additionallnformatinnl
See Attachments: .1) Grading Plan,-.2) Erosion Control Measures
..." 3.) Frn~inn Conlrol Plan
"The issuance or granting of a permit or approval of plans, specifications and
computations shall not be construed to be a permit for, or an approval of, any violation of
any of the provisions of this code or of any other ordinance of the jurisdiction. Permits
presuming to give authority to violate or cancel the provisions of this code or other
ordinances of the jurisdiction shall not be valid."
{I
'f/I
SITE ADDRESS
TYPE OF WORK
USE OF BUILDING
PERMIT NO. n/-/3/'7 DATE ISSUED //- 2..~-()/
BUilDER JliENDOe.~W~N<;I'1ANAJ PHONE #
NOTE: THIS IS NOT A P RMIT FOR ANY OF THE INSPECTIONS BELOW
THE PERMIT IS BY SEPARATE DOCUMENT
RIOR LAKE ~~rtD~TMENTOF
INSPECTI
RECORD
/5300 crSFFE/c.:5 PASS
R6GClL C,e6s/ KGI/1/N'/N~LL
. ,
INSPECTOR
DATE
I I
PLACE NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED
I I
'-
1'/1
~l~
-"
Call between 8:00 and 9:00 A.M. for all inspections
FOR ALL INSPECTIONS (952) 447-9850
DATE TIME
SCHEDULED ~~
JS.2su
CITY OF PRIOR LAKE
INSPECTION NOTICE
ADDRESS 17~
OWNER
CONTR.
PHONE NO.
PERMIT NO.
o FOOTING
o FOUNDATION
o FRAMING
o INSULATION
o FINAL
o SITE INSPECTION
o PLUMBING RI
o MECH RI
o WATER HOOKUP
o SEWER HOOKUP
o PLUMBING FINAL
o MECH FINAL
COMMENTS:
/l
Q,L~- w l'('
..
I
{- (S Q
o EXIGRADIFILLING
o COMPLAINT
o FIREPLACE RI
o FIREPLACE FINAL
o GASLINE AIR TST
o
t
{
lo
,
/'
~RK SATISFACTORY, PROCEED
o CORREC C ON AND PROCEED
o CORR LL FOR REINSPECTION BEFORE COVERING
Owner/Contr:
o FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE..
REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH &: SAFETY!
lNSNOTl
DATE TIME
CITY OF PRIOR LAKE
INSPECTION NOTICE
SCHEDULED
/ -1'-/-cJ1
PHONE NO.
/53co J~ffer..> /JG,r;.5
CONTR. ./Ltl'c9~#' (,pIl5/..
PERMIT NO. .CJ {-/3/7
,
,~LING
o coMistXiNT
o FIREPLACE RI
o FIREPLACE FINAL
o GASLlNE AIR TST
o
o PLUMBING RI
o MECH RI
o WATER HOOKUP
o SEWER HOOKUP
o PLUMBING FINAL
o MECH FINAL
ADDRESS
OWNER
o FOOTING
o FOUNDATION
o FRAMING
o INSULATION
~L
o SITE INSPECTION
COMMENTS:
r;,~')-~,<-
)J~
. J--J :.J' t:' ./
~.N' ~
O.1r
./~
~RK SATISFACTORY, PROCEED
o CORRECT ACTION AND PROCEED
o CORRECT WORK, CALL FOR REINSPECTION BEFORE COVERING
Inspector:~ Owner/Contr:
CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE.
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY!
lNSNOTl
~ ~
~101~~~1 'C
"RETAINING WALL SYSTEMS
, A CCNTECH COMPANY
4444 West 78th ~treet · Minneapolis, MN 55435
www.keysfonewolll.com . 800]47.8971 . 952.897.1040 . fox: 952.897.3858
OESIG~
CALCLLA'l'IO~S
FOR
Regal Crest
Prior Lake, Minnesota
11/6/01
dIm
I hereby certify that this plan
specification, or report was prepared by me
or under my direct supervision and that I am
a duly R~~~ed Professional Engineer un-
der ~ !~~7r Minneso~.
Date l1. b RBg. No. 20589
~:J-10.~ T:':'
~J ul~~j "L.
REJAINI\G \~'A_L 5 YST:: 1\.1 5
KEYSTONE RET AlNING WALL DESIGN
Based on Rankine (modified) Methodology
3.1.3
:A~lt::MI COMPANY
Project: Regal Crest
Proj. No.: 01-380
Design Parameters
Date: 11/2/01
By: dIm
81//,/3
I' '2
'I I
tW 11
2.00 Bearing: 2.00
1.50
1.50 Serviceability: N/A
Base Friction used in Tension of base grid
Soil Parameters ~ c psf
Reinforced Fill: 28 0
Retained Fill: 28 0
Foundation Fill: 28 0
Reinforce Fill Type: Silts & sands
Unit Fill: Crushed Stone, 1 inch minus
LJ2ff
120
120
120
Factors of Safety
Sliding:
Pullout:
Connection
1.50
1.50
Overturning:
Uncertainties:
Peak:
Reinforcing Parameters: Mirafi XT Geogrids
Tult RFcr RFd
Miragrid 05XT 3591 1.67 1.10
RFid
1.13
LTDS
1730
FS
1.50
Tal
1153
Analysis: Wall #1 @ 50'
Unit Type:
Leveling Pad:
Wall Ht:
Level Backfill
Surcharge: LL--
Compac
Crushed Stone
7.67 ft
Case: Case 1
Wall Batter: 8.80 deg.
Ci
0.80
Cds
0.80
embedment: 1.33 ft (not used in bearing calc.)
50 psfuniform surcharge DL -- 0 psfuniform surcharge
Offset= 1.00 ft; Load Width= 100.00 ft
Slidin~ Overturnin~
2.21 5.10
Results:
Factors of Safety:
Calculated Bearing Pressure: 958 psf
Eccentricity at base: 0.30 ft
Reinforcing: (ft & lbs/ft) Calculated
Laver Heil!ht Lenl!th Tension Reinf. Tvoe
3 6.00 6.0 171 Miragrid 05XT
2 4.00 6.0 299 Miragrid 05XT
I 2.00 6.0 446 Miragrid 05XT
Reinforcing Quantities (no waste included):
Miragrid 05XT: 2.00 sy/ft
Bearinl!
5.64
Allow. Peak
Tension Connection
Tal Tel
1153 ok 540 ok
1153 ok 577 ok
1153 ok 614 ok
(% of Rein. Strength Used = 35 %)
Pref: HingeHt.! Base F.I
- I -
KEYSTONE RETAINING WALL
C:\My Documents\ACAD Projects\Minnesota\01-380 Regal Crest\01-380 Key .kwp
Shear
4.99
Bendin,g
2.96
Serviceablity
Connection
Tsc
N/A
N/A
N/A
Pullout
FS
2.31 ok
4.02 ok
5.33 ok
page
of
~I~~L
f'- 1-'1 ,. ~ ;::;;. "...,
.L ~ ~.J~ :'(jg~.! _,
RE;TAINI\G ':VA:""L SYST::i\'lS
KEYSTONE RETAINING WALL DESIGN
Based on Rankine (modified) Methodology
3.1.3
COt...~ICOMPANY
Project: Regal Crest
Proj. No.: 01-380
Design Parameters
Date: 11/6/01
By: dIm
Soil Parameters --L c osf
Reinforced Fill: 28 0
Retained Fill: 28 0
Foundation Fill: 28 0
Reinforce Fill Type: Silts & sands
Unit Fill: Crushed Stone, 1 inch minus
L1l9
120
120
120
D jY/4
1/
Factors of Safety
Sliding:
Pullout:
Connection
1.50
1.50
Overturning:
Uncertainties:
Peak:
2.00 Bearing: 2.00
1.50
1.50 Serviceability: NI A
Base Friction used in Tension of base grid
Reinforcing Parameters: Mirafi XT Geogrids
Tult RFcr RFd
Miragrid 05XT 3591 1.67 1.10
RFid
1.13
LTDS
1730
FS
1.50
Tal
1153
Analysis: Wall #2 @ 80'
Unit Type:
Leveling Pad:
Wall Ht:
Level Backfill
Surcharge: LL--
Compac
Crushed Stone
9.67 ft
Case: Case 1
Wall Batter: 8.80 deg.
3
I
;2
III
Ci
0.80
Cds
0.80
embedment: 1.33 ft (not used in bearing calc.)
50 psfuniform surcharge DL -- 0 psfuniform surcharge
Offset= 1.00 ft; Load Width= 100.00 ft
Slidin~ Overturnin~
2.07 4.49
Results:
Factors of Safety:
Calculated Bearing Pressure: 1225 psf
Eccentricity at base: 0.45 ft
Reinforcing: (ft & lbs/ft) Calculated
Laver Heil!:ht Len!!th Tension Reinf. Tvne
4 8.00 7.0 171 Miragrid05XT
3 6.00 7.0 299 Miragrid 05XT
2 4.00 7.0 446 Miragrid 05XT
1 2.00 7.0 593 Miragrid 05XT
Reinforcing Quantities (no waste included):
Miragrid 05XT: 3.11 sy/ft
Bearin~
5.00
Allow. Peak
Tension Connection
Tal Tel
1153 ok 540 ok
1153 ok 577 ok
1153 ok 614 ok
1153 ok 628 ok
(% of Rein. Strength Used = 40 %)
Pref: HingeHt.! Base F J
- I -
KEYSTONE RETAINING WALL
C:\My Documents\ACAD Projects\Minnesota\01-380 Regal Crest\01-380 Key .kwp
Shear
3.92
Bendin~
2.96
Serviceablity
Connection
Tsc
N/A
N/A
N/A
N/A
Pullout
FS
2.42 ok
4.16 ok
5.4 7 ok
6.75 ok
page
of
~I~" 1":7
~J ~ J ~~j ,,-!:,
RE1:\It'~I\G \VA_L SYST:::i\1S
KEYSTONE RETAINING WALL DESIGN
Based on Rankine (modified) Methodology
3.1.3
..<<A.COt..~ COMPANY.
Project: Regal Crest
Proj. No.: 01-380
Design Parameters
Date: 11/2/01
By: dIm
~ I 'i,
1/ / .if
2.00 Bearing: 2.00
1.50
1.50 Serviceability: N/A
Base Friction used in Tension of base grid
Soil Parameters ~ c Dsf
Reinforced Fill: 28 0
Retained Fill: 28 0
Foundation Fill: 28 0
Reinforce Fill Type: Silts & sands
Unit Fill: Crushed Stone, 1 inch minus
y pc[
120
120
120
Factors of Safety
Sliding:
Pullout:
Connection
1.50
1.50
Overturning:
Uncertainties:
Peak:
Reinforcing Parameters: Mirafi XT Geogrids
Tult RFcr RFd
Miragrid 05XT 3591 1.67 1.10
RFid
1.13
LTDS
1730
FS
1.50
Tal
1153
Analysis: Wall #3 @ 65'
Unit Type:
Leveling Pad:
Wall Ht:
Level Backfill
Surcharge: LL --
Compac
Crushed Stone
11.67 ft
Case: Case 1
Wall Batter: 8.80 deg.
Ci
0.80
Cds
0.80
embedment: 1.33 ft (not used in bearing calc.)
50 psfuniform surcharge DL -- 0 psfuniform surcharge
Offset= 1.00 ft; Load Width= 100.00 ft
Slidinl{ Overturnin~
1.93 4.10
Results:
Factors of Safety:
Calculated Bearing Pressure: 1498 psf
Eccentricity at base: 0.60 ft
Reinforcing: (ft & lhs/ft) Calculated
Laver Heil!ht Lenl!th Tension Reinf. Tvne
6 10.00 8.0 171 Miragrid 05XT
5 8.00 8.0 299 Miragrid 05XT
4 6.00 8.0 446 Miragrid 05XT
3 4.00 8.0 593 Miragrid 05XT
2 2.00 8.0 606 Miragrid 05XT
1 0.67 8.0 412 Miragrid 05XT
Reinforcing Quantities (no waste included):
Miragrid 05XT: 5.33 sy/ft
Bearing
4.56
Allow. Peak
Tension Connection
Tal TeI
1153 ok 540 ok
1153 ok 577 ok
1153 ok 614 ok
1153 ok 628 ok
1153 ok 628 ok
1153 ok 628 ok
(% of Rein. Strength Used = 39 %)
Pref: HingeHt./ Base F./
- I -
KEYSTONE RETAINING WALL
C:\My Documents\ACAD Projects\Minnesota\01-380 Regal Crest\01-380 Key .kwp
Shear
3.83
Bending
2.96
Serviceablity
Connection
Tsc
N/A
N/A
N/A
N/A
N/A
N/A
Pullout
FS
2.53 ok
4.29 ok
5.61 ok
6.89 ok
9.95 ok
> lOok
page
of
.
GENERAL DESIGN NOTES
1. The following effective strength design parameters were assumed in the
preparation of structural calculations for the Keystone retaining wall system:
. ct> c (pst) y (pct) Soil Type
280 0 120 SM - Silty Sand
280 0 120 SM - Silty Sand
280 0 120 SM - Silty Sand
Reinforced Soil
Retained Soil
Foundation Soil
Soil types and design properties shall be confirmed by the Owner or its
geotechnical engineer prior to wall construction. Keystone accepts no
responsibility for the interpretation or verification of subsurface conditions.
2. The system has been evaluated for internal stability and simple external sliding
and overturning. Unless otherwise specified, the design maintains a minimum
factor of safety of 1.5 on all elements of the wall design.
3. The walls are designed to support the following maximum surcharge loadings:
Live Load - 50 psf
Backslope - Level
Seismic - nfa
Hydrostatic - nfa
4. The wall foundation soils at each wall location shall be capable of safely
supporting J. 500 p~f or as indicated on the wall elevations without failure or
excessive settlement. Local bearing capacity shall be confirmed by the site
engineer.
5. The Contractor shall provide surface and subsurface drainage, grading, and
erosion control during and after wall construction to avoid damage to the wall
structure.
6. The Contractor is responsible for obtaining all permits and easements
necessary for wall construction. The Contractor is responsible for protecting
adjacent properly from wall construction activities.
Copyright 2001 Keystone Retaining Wall systems
Design is for internal stability of the KEYSTONE waD structure only. External stability,
Including but not limited to foundatioo and slope staIliIIly Is the rasponsitliIity of Iha OMlor.
The design is based on the assumption that the materials within the retained mass, methods
of constlUction, and quality of materials conform to KEYSTONE., specification for this
projeel.
No.
Revision
Dale
This drawing is being furnished for this specific: project only. Any party ...,,.,.' -a. this
document does so in confidence and agrees that il shall not be duplicated in whole Of In
part. nor disclosed to others without the consent of Keystone Retaining Wall Systems, Inc.
Regal Crest
Prior Lake, Mmnesom
DRAWING INDEX
Description
Sheet No.
Title Sheet
Site Plan
Wall Elevations #1
Wall Elevations #2
Wall Elevations #3
Wall Sections
Typical Com pac Unit Details
Specifications
1
2
3
4
5
6
7
8
By
T/D1C"'P' 1//.1\. 1:'
l'\J,...:J oJ j ~4~~j 't..:,
RET:\I>J\C' \~L S', STDIS
A CONIBH COMPANY
4444 W 78th SIr8eI
Minneapolis, MN 55435
952-397-1040
Dale:
~
QUALITY ASSURANCE PROVISIONS
1. Wall construction shall be monitored by a qualified Engineer to verify field
conditions. If this work is not performed by the site geotechnical engineer, the
geotechnical engineer shall be consulted in those matters pertaining to soil
conditions and wall performance.
2. The foundation soils at each wall location shall be inspected by the Engineer
and any unsuitable soils or improperly compacted embankment material removed
and replaced as directed by the Engineer prior to wall construction to provide
adequate bearing capacity and minimize settlement.
3. All wall excavation and retained soils shall be inspected for groundwater
conditions and any additional drainage provisions required in the field shall be
incorporated into the wall construction as directed by the Engineer.
4. Wall backfill material shall be tested and approved by the Engineer for use in
the reinforced soil zone meeting the minimum requirements of the approved
design plans.
5. All soil backfill shall be tested by the Engineer for moisture, density, and
compaction periodically (every 2' vertically, 100'-200' clc) meeting the minimum
requirements of the approved design plans or project specifications.
6. Wall construction shall be periodically inspected by the Engineer to insure the
geogrid reinforcement elevations and lengths are installed in accordance with the
approved design plans.
7. All wall elevations, grades, and backslope conditions shall be verified by the
Engineer in the field for conformance with the approved design plans. Any
revisions to the structure geometry or design criteria shall require design
modification prior to proceeding with construction.
Designed By:
dIm
nle:
Title Sheet
Dale:
11/5101
Checked By:
cdm
Project:
Project No:
01-380
Regal Crest
Prior Lake, Minnesota
Drawing No:
Reg. No. 20589
Scale:
NO SCALE
,
"'1
The site plan is for illustrative purposes
only. It has been reproduced from the site
retaining wall plan prepared by others.
Design is for intemat stability IX the KEYSTONE wall strucbJre only. External stability,
including but not limned to foundation and sIope.-;!vis lhe_.. ......ityollheOwner.
The design is based on the assumption that the materials within the retained mass, methods
of construction. and quality of materials conform to KEYSTONE's !~ ..... _. >. . for this
projeel.
Revision
By I
Copyright 2001 Keystone Retaining waa Syslems
No_ Date
T/L\lCl,,\I/~1\. r
l~J ..J j ~.n~j 'L.
RET,\I' :\ -, 'ILL SYSTE'.IS
This drawing Is being fumis.hed for this specific project only. Arty party ., ....., ~ "L this
document does so in confidence and agrees lhal il shall not be duplicated in whole or in
part, nor disclosed 10 olhers without Ihe consenl of Keys&one Relaining WaM Systems. Inc.
A COIIIB:H COMPANY
4444 W 7111h Slnlel
Minneapolis, MN 55435
952-897-1040
I
Date:
Designed By: Title: Date:
dim Site Plan 11/5/01
Checked By: Project: Project No:
cdm Regal Crest 01-380
I Scale: Prior Lake, Minnesota Drawing No:
Reg. No. 20589 NO SCAlE 2
~
~
GENERAL NOTES:
1. The wall is to be constructed with Keystone
Com pac units using 1" setback (1H:8V).
2. The design requires Mirafi 5XT soil
reinforcement at the elevations shown.
o
o
o
o
Iii
3:
c:
'0,
CD
co
g tii
cO 3:
CJ) "C
c:
W
r EL = 964.00
r EL = 96~.00, ' r , r EL = 960.00
.' I. ' MIRAFI5T@962.3:1 "L.l. 0-
~- I I MIRAFI 5T @ 960.3:1 .
I I I.J I I I I
~____ __n__..____________________________n _______________________._______.n________n~_~~~_I_~I_@_~?_~;~~_n__________________________________ ___n____________________n_________ l ~
.. · · · · · · · \. · · · · · · · · · · · · · · · · · · · · · · · t ;,N,~~E~ G~~E' A~ ~~o~ ~F ~~L;mm..m..mmm..mm.m...mmmm.... '.
\.- EL = 956.33
6' Geogrid Depth
(Compac Units - 1" Setback)
Jrcement
I (feet)
(l,long
feet)
I I I I I I I I
I II
10
I I , I ' , J
, I'
I I I I I I I
J I'
, I , I ' I ,
I I'
I I I I I I I
J I'
, I ,
I' , , J I' , I , I ' , , , I'
60 70
I , I I II , , I'
80
, , , I I , ,
, I'
90
II I I I
o
20
30
40
50
__K~Y~J9J:l~_'fj~!Lttt:__f!.9ntE9_~_.I;Jg~~ljQ!'!___
Copyright 2001 Keystone Retaining Wall Systems
Design is for internal stability of the KEYSTONE wall structure onty. External stability,
including but not limited to foundation and slope stability is 1he responsibHity of the Owner.
Th, design is based on the assumption that the materials within the retained mass, methods
of construction. and quality of materials conform to KEYSTONE', specification for !his
project.
No.
Date
Revision
By
T/r:VC'T}\I/?" r
l~J oJ j ~A~~j "L.:.
RETr\r;;'.c' ILL SYSTE\ IS
This drawing is being furnished for this specific projed only. Any party ~.......... .. this
document does so in confidence and agrees that it shall not be duplk:aIed in whole or in
part. nor disclosed 10 others without the consent of Keystone Retaining Wall Systems, Inc.
A CONIB:H COMPANY
4444 w 78th Street
Minneapolis, MN 55435
952-897-1040
......,~~...,-......, ~-- Designed By: Title: Date:
under my direct su sion and that I am a duly dim Wall Elevation #1 11/5/01
registered Pro~ ~er7 of the
State of Min . Checked By: Project: Project No:
:t' cdm Regal Crest 01-380
:/I .
Date: AI'/ol/ Scale: Prior Lake, Minnesota Drawing No:
Reg. No. 20589
1" = 10' 3
,
g iii
o ~
o c:
'0,
Q)
III
0 iii 0 Q)
0 0 c:
to ~ 0 ::J
C1> " N .s::
c: ...... 0
Q) 10
III ::E
r EL = 955.00
EL = 953.007
m'~~1 ~T '@ ~5~.67" I'" r EL = 9511.00
, -lI_J
MIRAFI 5T @ 950.67. ' ,u,_~_' ';---'---i r
L.--.~---:-l~-~'.----- ,-. __.____.._ MIRAFI 5T@948.67""','" , ~I~---'-i
, , ',' \ , ,--.---..--j-;--.----.----.--.-.----.----.----.----,--..,---_,-___,-m,-_.----M1RA-F1-frT-@-946,&1'u__________.__m__ ' I . I , I ~
EL = 948.67 ~ I , , , , , , , , , , ',' ~' -:--..----,---..-..-.--i-:;~ ~-._---._---~-----.,-MIRAF-I.5I-@_~1:~Y________~..____
1111111 ~
FINISHED GRADE AT BOTTOM OF WALL I ~' , , , , , , ,
EL = 944.67
EL = 942.67
E' J ' , , ,
t <--'l~:---,-'-',-.-
L EL = ~52'.67'
.------------
I! Ll
,
, '
Reinforcement ~
Depth (feet) .
7' Geogrid Depth
(Compac Units - 1" Setback)
Dist. Along
Wall (feet)
r I I I I I I I I I I' I I I I I , , , I' I , , I I , , , I' I , I I ' , , I I' I , , I I , , , I' , , , I ' I , , I' , I , I ' , , , I' , I , I ' , ,
o 10 20 30 40 50 60 70
, I' , , , I I , , I I' , , , I I , , , I' , , , I I , , , I' I , I I ' , , , I' I I I
80 90 100 110 120
.Keystone Wall #2 - Front Face Elevation
0 Q) 0 Qj lC)
0 c: C! N iii
0 ::J c: ~
r:: (; cO
N .s:: ......
...... 0 () N "C
10 c:
iii w
::E ~
L = 951.00
(EL = 951.00
I '
t \.. J I ,----.--- .
" MIRAFI 5T @ 948.67
"MIRAFI 5T @ 946.67
, '
, ',' ___....__.____:_~!~!:!.~I.~_~~~~Y___________________________....._.______.___.______________________...___.__..___.._!_ .!_._!.____.____.____ ------ ____n_
I I \. I I I I I I I i I I
, , , , , , , , , . , \' , , , , , , , , , , , . , , , , , '~'FINI~H~DGRADEATBOTTOMOFWALL
942.67 L EL = 942.67
:-I--T--+_--~
1111 I
r EL = 949.00
GENERAL NOTES:
, J
[ EL = 946.33
"~
,---,- - ~ EL = 944.67
1. The wall is to be constructed with Keystone
Com pac units using 1" setback (1H:8V).
2. The design requires Mirafi 5XT soil
reinforcement at the elevations shown.
I I.J
I ,---yo--",,:
,
I - -,--..,.----=.
, , ,
'---T':-~ _
I' ,
I ---.----,
T---.
, ,
I ".J
7' Geogrid Depth
(Compac Units - 1" Setback)
I I I I' I I I I' I I I I' I I I I I , , I I' I , I I ' , , , I' , I I I ' , I , I' I , , I I , , , I' I , , I ' , , , I '
120 130 140 150 160 170 180
I I I I I I
I I' , , , I ' , , , I' , , , I I I I , I' I I , I I , 'I
190
200
210
J<eystone Wall #2 - Front Face Elevation
Copyright 2001 Keystone Retaining Wall Systems
Design is fo< _ stability c11he KEYSTONE waI slnJcture ooIy. Extemal stabilly.
lneluding but nolllmlled 10 foundation and slope .-.y is tho '~',. ..-. -Ity cI tho Owner.
The design is based on the assumption thai the materials wittWn the retained mass. meIhods
of construction. and quality of materials conform 10 KEYSTONE's ~... _ ~. _;Ion for Ihis
projed.
This drawing is being furnished rot this speeifie prcjed only. /4nt _ ..". . this
document does 10 in confidence and agrees that it shall no( be dupIicaIed In whole Of" in
part. nor diselosed 10 ~ wilhoul tho consent cI ~ RMM1ing WoI SysWns. 'no.
No.
Date
Revision
By
T/C\1(~T~\'//.1\. L'
l~ J ...) j ~~~~j 'L.:,
RET ..:' P ~. , ,~L SYSTE' IS
A CONI'ECH COMPANY
4444 w 78th Slnlel
Minneapolis, MN 55435
952-897-1040
I hereby certify that this Ian was prepared by me or Designed By: TiUe: Date:
under my direct su ion and that I am a duly dim Wall Elevation #2 11/5101
registered p~nee.:?the laws of the
StateolMln . V ~ Checked By: Project: Project No:
cdm Regal Crest 01-380
v h tI, /0,( Scale: Prior Lake, Minnesota Drawing No:
Date: Reg. No. 20589
,/ . 1" = 10' 4
~
g (ij
ci 3:
o c:
'0,
Q)
lD
o Ul
o ::::l
-i :c
N ri.
c:
'0,
Q)
lD
o Ul
o ::::l
<Xi :c
~ ri.
u
c:
UJ
r EL ~ 943.33
r EL ~ 944.00
o Q)
o c:
ci ::J
N .c
... 0
Cii
~
EL = 940.00 7
~ ,
._, _,..' ,I
... ,
, ,
"'f-- I
\
, )
I . 11-~-f---1
---roo, .
i-- }---T---f.--t~-.-t---t---~_____ --"":
. ....J..... . .
I --T---T---T---th-t---+-=-;-tr."9
~
~
~
_ _ _________________S;f:
r l I I
EL ='9336~ ~ ,-
[ EL = 932.6~_,
~,
~"II
[EL = 928.00 - ,r ~
..--+-VI r~' I MIRA I 5T @ 931.00 ___---
~ -'j__-' L;-'. M'IRA. FI 5T@929:OO-- ---------;r-- ~' , I I I
_~ ---l --I ...J I ~ _______--------- r - I I I ~.J I I
1 ' :_:_:~]-F3A.E17T-~~~00,... I I I I
, l ' , , I EL = 929.00
~ EL = 925,00
>-:-:1 ~.-
-\J
L~I
-..- I
I
....--1
,
MIRAFI5T@ 942.33-
MIRAFI 5T @ 940.33-
MIRAFI 5T @ 938.33.
MIRAFI 5T @ 936.33-
__________________________MJMfL5J_@..934.3.1
MIRAF 51Jtt~?.~A!Q:_________ '"'F I
;_n:--:n\{FIN':HED ~RA~~:~ ~~DM ~F:::;m;m;_- ~'EL'= ~3~3~ ' , ' , , ,
, , .J
Reinforcement
Depth (feet)
8' Geogrid Depth
(Com pac Units - 1" Setback)
I
Dist. Along
Wall (feet)
I I I , I' , , , I' , , , I ' , I , I' I , , I ' I I , I' , I , I I , , I I' , , , I I , , , I' , ,
o 10 20 30 40 50
, I ' , , , I' , , , I ' , , , I' , , , I ' I , , I' , , , I ' , , , I' , I , I ' , , , I' , , , I ' , I I I' , , , I ' , , ,
60 70 80 90 100 110 120
Keystone Wall #3 . Front Face Elevation
o Q)
o c:
ci ::J
N .c
o
Cii
~
r EL = 942.67
~ ~~ ' "M';"';"~~ ~;;;~;n';_..,.' ;; " ";t, , EL = 938007
::r:'.., MIRAFI 5T @ 938.3:.' ' I -'--, I I - - .
:Q MIRAFI 5T @ 936.3:.' __________mL.' ':',.: ::.~
~n:n;n;m~~lCE:;:3~:-i~~NIS~::::D:AT-BO:::-O::~L ; , '~L ~ ~:7 ~
~ (ij
a; 3:
u
c:
W
GENERAL NOTES:
1. The wall is to be constructed with Keystone
Com pac units using 1" setback (1H:8V).
2. The design requires Mirafi 5XT soil
reinforcement at the elevations shown.
8' Geogrid Depth
(Compac Units - 1" Setback)
I' , , I II I I , I' I , , I' I , , II , I I I' , , I I' , , I I' , , I I' , I , I I , , , I' I , , I' I I , II
120 130 140 150 160 170 180
Keystone Wall #3 . Front Face Elevation
Copyright 2001 Keystone Retaining Wall Systems
Design is for internal stability m the KEYSTONE wal structure onty. External stability,
Including but not limited to foundation and slope stability is the. .4... _. ~ m".,,' d the Owner.
The design is based on the assumption that the materials within the retained mass, methods
of conslructton. and quality of materials conform 10 KEYSTONE's specification for this
project.
No.
Date
Revision
By
T/L\/(~}\ I/~ l\. L'
l"J,.:J ..) j ~.n~j '!..:.
RET\r\l\'~' \LL SYSTE\IS
This drawing Is being furnished for this specific project only. Arty party. ~ ~ "r'.' ''*' this
document does so in confidenc:e and agrees that it shall not be duplk:ated in whole or in
part, nor cfisdosed to others without the consenl 01 Keystone Retaining W8lt Systems. Inc.
A CONIEcH COMPANY
4444 w 78th Slleet
Minneapolis, MN 55435
952-897-1040
Date:
Designed By: Title: Dale:
dim Wall Elevation #3 11/5101
Checked By: Project: Project No:
cdm Regal Crest 01-380
Scale: Prior Lake, Minnesota Drawin9 No:
Reg. No. 20589 l' = 10' 5
....
General Notes:
Drainage pipe is not required directly behind the wall units for conventional wall construction where
retained soils are not a source of groundwater such as fill wall construction or cut walls into
relatively dry banks. Drainage pipes are required where groundwater conditions mandate additional
drainage provisions such as cut wall construction into potential water bearing slopes. Generally,
additional drainage material such as aggregate drains & fabrics and/or drainage composite nets are
used in conjunction with pipe drains for this purpose.
A geotextile filter fabric separator is required between the unit drainage material and site backfill
soil in any application where freewater is expected upon the wall face such as in a detention pond
or along waterways where the high water level may be above the bottom of wall. Use of filter fabric
shall extend a minimum of 1 foot above the anticipated high water level.
A fence, railing, guardrail or other protective barrier is typically required along the top of all walls
as required by the site engineer and local codes. The choice, location, and compliance to local
codes of the appropriate barrier system is the responsibility of the owner and its site engineer.
Fen", (' ,",,"in>d) \ '
3'Min.
0" Min. Low Pe="b1e Soil \
\
\
( Retained SOil) \
\
Limits /L
r Koystone Co, Un'
G~~
Unit Drainage Fill - ~
( Reinforced Soil )
\
\
- - 7\.A)
,..
Drain Pipe (if required)
. "-.1
( Foundation Soil )
Copyright 2001 Keystone Retaining Wall Systems
Design is to< internal stabiily 01 the KEYSTONE wal slrUcIure only. Externalstabilily.
Induding but nolllmHed to foundation and slope stabily is ... rospomDlily 01... Owner.
The design is based on the 8ssumption that the materials within the retained mass. meIhods
of constructfon. and quality of materials oonIorm 10 I.e..... I \"I1~E's spec:ification tor Ihis
project.
This drawing ls being furnished 'Of this specific prcjed. only. Any perty _ ~ ~ _ " '.1 INs
document does so in confidence and agrees that it shall not be duplicaIed in whole 0( in
part. nor disclosed 10 ~ wilhout the consenl at Keyslcne RMMling W" SysBns, Inc.
Keystone Compac Unit
Fen'" (' ,",,"i..d) \ '
3'Min.
0" Min. Low Pe_ble Soil \
\
\
\
\
\
( Retained Soi0 \
Urn" /\
/ Fin.hod G""'e
Wall #1 Section CO2 80' (Typical To Wall #2)
Compac Unit - 1" Setback
No.
Date
Revision
By
Vf:'\7~\II//1\. 1:'
l~J oJ j ~~~~j 'L.
RET!\J\I\C ,~L SYSTE:llS
A CONIBH COMPANY
4444 w 78th Slnlel
Minneapolis, MN 55435
952-897.1 D40
Unit Drainage Fill
\\
Unit Drainage FilW \
L-
\
\
\
\
\,O~
- - - 7 L.....-.I
Drain Pipe (if required)~
( Reinforced Soil )
(Foundation Soil )
'\.
Keystone Cap Unit
Keystone Compac Unit
/ Finished G,ade
Wall #3 Section @ 86'
Com pac Unit - 1" Setback
Designed By:
dim
Tille:
Checked By:
cdm
Project:
Rag. No. 20589
Scale:
No Scale
Typical Wall Section Details
Date:
11/5101
Regal Crest
Prior Lake, Minnesota
Project No:
01-380
Drawing No:
6
,
..
Base LevelinQ Pad Notes:
Mini Cap Unit
Width: 18"
*Oepth: 101/2"
Height: 4"
*Weight: 45 Ibs
1. The leveling pad is to be constructed
of crushed stone or 2,000 psi:!:
unreinforced concrete
Slope Cut
2. The base foundation is to be approved
by the site geotechnical engineer prior
to placement of the leveling pad.
Com pac Unit
Width: 18"
*Oepth: 12"
Height: 8"
*Weight: 85 Ibs
6" Crushed Rock or
Unreinforced Concrete
Leveling Pad
./'
.Compac Unit/Base Pad Isometric View
*Oimensions & Weight May Vary by Region
Note:
1.
Check with manufacturer specifications
on correct direction of orientation for
geogrid to obtain proper strength.
3" of Soil Fill is Required
Between Overlapping Geogrid
for Proper Anchorage
Minimum Wall Radius:
Inside Curve: 4.0' (at bottom of wall)
Outside Curve: 4.0' (at top of wall)
Geogrid Installation on Curves
Copyright 2001 Keystone Retaining Wall Systems
Design is for internal stability cfthe KEYSTONE waM structure onty. External stability,
Including but not limfted to foundation and slope s~ Is tho mponsiIJiIIly d Iho Owner.
The design is based on the assumption that the ';" ',;, d wittW\ the retained mass. methods
of construction, and quality of materials conform 10 I~C I"....... ,E's specification for this
projeet.
No.
Revision
Oate
This drawing is being furnished for this specific projedonly. Any party . ",,,,,",,', ,I. this
documenl does so in confidence and agrees thai it shall not be dupllcaIed in whole Of In
part, nor disclosed to others without Ihe consent of KeysIone Retaining WaI Systems, Inc.
'"
I
I
r
6"
12"
Section
Leveling Pad Detail
^
c:
o
U
!!:?
is _____________
[---------] J I=--------J
~~'-J~-~~~~-:~--I~l:=-
-l_.. ~:-~~:::-~~
Geogrid is to be Placed on Level
Backfill and Extended Over the
Fiberglass Pins. Place Next Unit.
Pull Grid Taught and Backfill.
Stake as required.
Grid & Pin Connection
By
"VL\.1~\ 1/// I\. T:'
l~J ~ j ~4~~j 'L.
RET/\I\;'.( LL SYSTE' 15
A CONIEcH COMPANY
4444 w 78th Street
Minneapolis, MN 55435
952-897-1040
(2) - 4" Cap Units or
(')-B"Cap",' \
/1 I
I
'I
J
I
II 4" Cap Unit
r 8" Com pac ~nit
" 1
1
I I
I
I
Saw Cut units70 Fit
Within 1/2" of Pipe
Control Joints
as required i
I I 1/' I]
I J I I
I /1 I I !
, I
Top of Wall Steps
Note:
1.
For pipes larger than 24", a concrete
collar may be cast around pipe for
ease of construction and appearance.
Concrete Collar
(if applicable)
I
I
I
I
II
}-
Scour Protection as Required.
Use Rip Rap or Concrete Slab
in Outlet Area.
]Ypical Pipe Outlet Detail.
I hel'filby certify that plan was prepared by me
under my direct s 'slon and that I am a
registered~m~ I ineer er aws oflhe
State of Mln .
V'
- ,)
Date: , I Reg. No. 20589
10
Designed By:
dim
Checked By:
cdm
I Scale:
NTS
Title:
Project:
.
. .
.
Co
" .
"
"
Com pac Elevation
+t
N
~
~'~Og:.~
~'" ;;7
18"
.Compac Plan
Compac Unit
*Oimensions May Vary by Region
Note:
1. Auger through geogrid layers.
2. Backfill or concrete guardrail
post in place.
3'Min.
-y Guardrail Post
M'" '" "''''~ .
-r-
I
-r- _ I
~ ~_~II~~'~~
Keystone Compac Unit
. ~~ "'''''''''''''1 '-- J .
c:
~
\... Geogrid
M
Typical Guardrail Detail
Typical Unit Details
Date:
11/5101
Regal Crest
Prior Lake, Minnesota
Pmject No:
01-380
Drawing No:
7
SPECIFICATION GUIDELINES (Short Form)
PART 1: GENERAL
1.01 DESCRIPTION
A. Work includes furnishing and installing a KEYSTONE retaining wall to the lines and
grades shown on the construction drawings and as specified herein.
B. Work includes preparing foundation soil, furnishing and installing leveling pad, unit
fill and backfill to the lines and grades shown on the construction drawings.
C. Work includes furnishing and installing all related materials required for construction
of the retaining wall as shown on the construction drawings.
1.02 REFERENCE STANDARDS
A. ASTM C1372 Specification for Segmental Retaining Wall Units
B. ASTM 0 422 Particle Size Analysis
C. ASTM 0 698 Laboratory Compaction Characteristics using Standard Effort.
D. ASTM 04318 Liquid Limit, Plastic Limit, Plasticity Index of Soils
E. ASTM 04595 Tensile Properties of Geotextiles - Wide Width Strip
F. ASTM 0 5262 Unconfined Tension Creep Behavior of Geotextiles
G. NCMA SRWU-1 Test Method for Determining Connection Strength of SRW
1.03 QUALITY ASSURANCE
A. Owner will be responsible for soil testing and inspection quality control during wall
construction and earthwork operations.
PART 2: MATERIALS
2.01 DEFINITIONS
A. Concrete Units - a KEYSTONE modular concrete facing unit, machine made from
portland cement, water and mineral aggregates.
B. Structural Geogrid - a structural geogrid formed by a regular network of integrally
connected tensile elements with apertures of sufficient size to allow interlocking with
surrounding soil, rock, or earth and function primarily as reinforcement.
C. Unit Drainage Fill - drainage aggregate which is placed within and immediately
behind the modular concrete units.
D. Reinforced Backfill - Compacted soil which is within the reinforced soil volume as
shown on the plans.
2.02 KEYSTONE UNITS
A. KEYSTONE wall units shall have a minimum 28-day compressive strength of 3,000
psi. Standard weight concrete shall have a maximum moisture absorption of 8% (6% in
northern climates).
2.03 FIBERGLASS CONNECTING PINS
A. Connecting pins shall be 1/2' diameter thermoset isopthalic polyester resin
pultruded fiberglass reinforcement rods supplied by the unit manufacturer.
2.04 KEYSTONE KAPSEAL CONSTRUCTION ADHESIVE
A. Material shall conform to ASTM 2339 and shall be supplied by the KEYSTONE unit
supplier.
2.05 GEOGRID REINFORCEMENT
A. Geogrid shall be the type as shown on the drawings having the property
requirements described within the manufacturer's specifications and required by the
design calculations.
2.06 BASE LEVELING PAD MATERIAL
A. Material shall consist of compacted crushed stone or unreinforced concrete as
shown on the construction drawings.
Copyright 2001 Keystone R_ Wall Systems
Design Is lor inlomal stability d tho KEYSTONE waI .tnJetunt only. External ,"biily.
Including but not limited to foundation and slope stability is Ihe responsibility d the 0Nner.
The design is based on the assumption that the materials within the retained mass, methods
of construction. and quality of materials conform to KEYSTONE's specification for this
project
No.
Revision
Date
This drawing is being furnished for this specific pn::;ect only. Any party " ~ ~ ~.,., ~ this
document does so in confidence and agrees that it shad not be duplicated in whole or in
part, nor disclosed 10 others without the consent of Keystone Retaining Wall Systems, Inc.
2.07 UNIT DRAINAGE FILL
A. Unit fill shall consist of clean 1" minus crushed stone or crushed gravel
meeting the following gradation:
Sieve Size
1 inch
3/4"
No.4
No. 50
% Passino
, 100
75-100
0-10
0-5
2.08 REINFORCED BACKFILL
A. Reinforced backfill shall be free of debris or organic material meeting the following
gradation tested in accordance with ASTM 0-422:
Sieve Size % Passinll.
.2 inch 100
3/4' 75-100
No. 40 0-60
No. 200 0-35
LL < 40 and PI < 15 per ASTM 04318
B. The maximum aggregate size shall be limited to 3/4" unless field tests have been
performed to evaluate potential strength reduction due to installation damage.
C. Material can be site excavated material when the above requirements are met.
Unsuitable soils for backfill (high plastic clays or organic materials) shall not be used in
the reinforced soil mass.
D. Contractor shall submit reinforced fill sample and test results to the
ArchitecUEngineer for approval prior to construction.
2.09 DRAINAGE PIPE
A. When required, drainage pipe shall be perforated or slotted PVC pipe
manufactured in accordance with ASTM F794 and F949 equivalent to A-2000
Perforated Pipe by Con tech Construction Products.
2.10 GEOTEXTILE FILTER FABRIC
A. When required, geotextile filter fabric shall be a 4.0 ozlsy, polypropylene,
needlepunched nonwoven fabric equivalent to C45NW by Contech Construction
Products.
PART 3: EXECUTION
3.01 EXCAVATION
A. Contractor shall excavate to the lines and grades shown on the construction
drawings. Contractor shall be careful not to disturb embankment and foundation
materials beyond lines shown.
3.02 FOUNDATION SOIL PREPARATION
A. Foundation soil shall be excavated as required for leveling pad dimensions shown
on the construction drawings, or as directed by the Engineer.
B. Unsuitable soils shall be removed and replaced with approved compacted material
as directed by the Engineer
C. Over-excavated areas shall be backfilled with approved compacted backfill
material.
3.03 BASE LEVELING PAD
A. Leveling pad materials shall be placed upon an approved foundation as shown on
the construction drawings to a minimum thickness of 6",
B. Aggregate material shall be compacted to provide a dense, level surface on which
to place the first course of modular units. Compaction shall be to 95 % of Standard
Proctor Density as determined in accordance with ASTM 0698. For crushed rock,
material shall be densely compacted as determined by visual observation.
By
T/fV"0T' \ 1/;.1\.. r
l~J ..) j ~A~~l 'L',
RET:".!'::' ~ L,- S., STD.IS
~
3.04 UNIT INSTALLATION
A. The first course of concrete modular wall units shall be carefully placed on the base
leveling pad. Each unit shall be checked for level and alignment.
B. Units are placed side by side for full length of wall alignment. Alignment may be
done by means of a string line or offset from a base line.
C. Install fiberglass connecting pins and fill all voids in and around the modular units
with unit fill material. Tamp or rod unit fill to insure that all voids are completely filled.
D. Sweep excess material from top of units and install the next course. Ensure that
each course is completely unit filled, backfilled and compacted prior to proceeding to
next course.
E. Place each subsequent course ensuring that pins protrude into adjoining' courses a
minimum of 1". Two pins are required per unit. Pull each unit forward, away from the
fill zone, locking against the pins in the previous course and backfill as the course is
completed. Repeat procedure to the extent of wall height.
3.05 GEOGRID INSTALLATION
A. Geogrid shall be laid at the proper elevations and orientation as shown on the
construction drawings or as directed by the Engineer.
B. Correct orientation (roll direction) of the geogOO shall be verified by the contractor
with the strongest direction placed perpendicular to the wall.
C. Geogrid soil reinforcement shall be connected to the KEYSTONE wall units by
placing the geogrid over fiberglass pins and laying the grid back on compacted fill.
Place the next course of units over the geogrid.
D. The geogrid shall be pulled taut to eliminate loose folds and pretension the
reinforcement. Stake or secure back edge of geogrid prior to and during backfill and
compaction. Geogrid shall be placed side by side with no gaps.
3.06 FILL PLACEMENT
A. Backfill material shall be placed in 8" lifts and compacted to 95 % of Standard
Proctor density as determined in accordance with ASTM 0698. The in place moisture
content shall not exceed the optimum moisture content as determined in accordance
with ASTM 0698 and be no lower than 3 % below optimum moisture content
B. Backfill shall be placed, spread and compacted in such a manner that minimizes
the development of slack or loss of pretension of the geogrid.
C. Only hand-operated compaction equipment shall be allowed within 3' of the back
surface of the KEYSTONE units.
D. Backfill shall be placed from the wall back towards the embankment to ensure that
the geogrid remains taut.
E. Tracked construction equipment shall not be operated directly on the geogrid. A
minimum backfill thickness of 6" is required prior to operation of tracked vehicles over
the geogrid. Turning of tracked vehicles should be kept to a minimum to prevent tracks
from displacing the fill and damaging the geogrid.
F. Rubber-tired equipment may pass over the geogrid reinforcement at slow speeds,
[less than 10 mph.] Avoid sudden braking and sharp turning.
G. At the end of each day's operation, the Contractor shall grade the backfill away from
the wall and direct runoff away from the wall face. The Contractor shall not allow
surface runoff from adjacent areas to enter the wall construction site.
3.07 CAP INSTALLATION
A. Place KEYSTONE Cap units over projecting pins from units below. Apply KapSeal
adhesive to top surface of unit below and place cap unit into position. Backfill and
compact to finished grade with low permeability soil.
A CONrICH COMPANY
4444 w 78th Street
Minneapolis, MN 55435
952-897-1040
Date:
Designed By: Title: Specifications Date:
dim 1115101
Checked By: Project: Projed No:
cdm Regal Crest 01-380
Scale: Prior Lake, Minnesota Drawing No:
NTS 8
,