Loading...
HomeMy WebLinkAbout09(B) - Consider Approval of the Villas of Crest Woods Preliminary Plat and a Planned Unit Development (PUD) Report13755 Crest Avenue NE Villas at Crest Woods Preliminary Plat / Preliminary PUD CrestAveNE138t h S t N E CrownlineDrNEApex Way N E C e darwood St NE Catt a i l C tN EJackson St NE1 4 1 s t S t NEWildflowerWayNE AspenAveNEMayfairRdNEJ a r e t t Ct NE P in n a c le Cir NE S h e f f i e ld Ter NE LupineTrlNEHampton St NE Meridian Way NE 42 18 Three Rivers Park District, Esri, HERE, Garmin, INCREMENT P, NGA, USGS, Scott County GIS 12 77 44 42 27 21 87 16 23 15 18 82 78 17 79 83 14 70 X:\Planning\Location Map\Location Map Template\13755 Crest Ave -.aprx 0 340 680 1,020 1,360 Feet Subject Property Subject PropertySubject Properties Wildflower Way NE 138th S t . NEMeridian Way NEApex WayLupine Trail NE 138th St. NEJackson Street NEBLOCK 1OTL. B 8 232221201918 1234BLOCK 3Street "B"Street "C"45679314123456810 112311BLOCK 7BLOCK 517 13127921GHOST PLATFUTURE ROADBLOCK 2OTL. CPOND /INFILTRATIONBASINWETLAND 3LEAST/LOWOHWL=998.10EX 100-YR HWL=998.57PR 100-YR HWL=999.55 EOF=1002.00WETLAND 1LEAST/LOWOHWL=1012.20EX 100-YR HWL=1014.24PR 100-YR HWL=1014.11EOF=1015.40FILTRATION BASINHAVEN RIDGE SOUTHINF EL=981.50OUTLET=982.32EX 100-YR HWL=986.61PR 100-YR HWL=986.99EOF=986.60WETLAND 2LEAST/LOWOHWL=1011.90EX 100-YR HWL=1015.45PR 100-YR HWL=1014.46EOF=1014.50WETLAND 4LEAST/LOWOHWL=1000.00EX 100-YR HWL=1002.32PR 100-YR HWL=1002.17EOF=1002.20WETLAND 7LEAST/LOWOHWL=979.42EX 100-YR HWL=985.12PR 100-YR HWL=985.94EOF=990.60BMP2INF EL=996.50OUTLET=998.10100-YR HWL=999.50EOF=1002.0065431 852 Exist.OTL. D7BLOCK 67 8 9 1 0 5 3 2 BLOCK 4 6 1 4BLOCK 591516BLOCK 1BLOCK 3OTL. ALupine Trail NE 10EOF1003.00EOF1002.20EOF1009.70EOF1015.40EOF994.40EOF986.60EOF990.60MAINTENANCE ACCESS MAINTENANCE ACCESSEOF999.00EOF1014.50EOF1003.13EOF1000.40EOF994.40EOF1014.06 Civil Engineering Surveying Landscape Architecture4931 W. 35th Street, Suite 200St. Louis Park, MN 55416civilsitegroup.com 612-615-0060THE VILLAS AT CREST WOODS PRIOR LAKE, MINNESOTA 7455 FRANCE AVENUE SOUTH, SUITE 351, EDINA, MN 55435 PRIOR LAKE DEVELOPMENT, LLC PROJECT ISSUE/SUBMITTAL SUMMARYDATEDESCRIPTION............PROJECT NUMBER:203026.15.21CITY RESUBMITTAL8.18.20CITY RESUBMITTAL........3-15-21PRELIMINARY PLAT/ PUD SUBMITTALDRAWN BY:REVIEWED BY:KTMP..............COPYRIGHT CIVIL SITE GROUP INC.cP R E L I M I N A R Y : N O T F O R C O N S T R U C T I O N26980KEVIN TEPPENLICENSE NO.DATEI HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION, OR REPORT WASPREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULYLICENSED LANDSCAPE ARCHITECT UNDERTHE LAWS OF THE STATE OF MINNESOTA.6-15-21REVISION SUMMARYDATEDESCRIPTIONC2.0OVERALL SITE PLAN21.05.10CITY REVISIONS..........01" = 100'-0"100'-0"50'-0"NKnow what'sbelow.before you dig.CallRPARK CALCULATIONS:1.RESERVED FOR CITY SPECIFIC NOTES.SITE DATA:TYPICAL 53' VILLA HOME LOT INFORMATION:LOT NUMBERPAD SIZELOT LINED & U EASEMENT10' FRONT & REAR5' SIDE (TYP.)BUILDING SETBACK25' FRONT25' REAR7.5' SIDES/ 25' SIDE ROW38'x70'PADROW LINECURB LINEMINIMUM LOT SIZE:6,360 SFTYPICAL 70' SF HOME LOT INFORMATION:LOT NUMBERPAD SIZELOT LINED & U EASEMENT10' FRONT & REAR5' SIDE (TYP.)BUILDING SETBACK25' FRONT25' REAR8' SIDES, TYP/ 25' SIDE ROW50'x55'PADROW LINECURB LINEMINIMUM LOT SIZE:8,125 SFSITE PLAN LEGEND:TRAFFIC DIRECTIONAL ARROW PAVEMENT MARKINGS(IF APPLICABLE)SIGN AND POST ASSEMBLY (IF APPLICABLE).SHOP DRAWINGS REQUIRED.NP = NO PARKING FIRE LANEST = STOPCONCRETE PAVEMENT (IF APPLICABLE) ASSPECIFIED (PAD OR WALK) SEE GEOTECHNICALREPORT FOR AGGREGATE BASE & CONCRETEDEPTHS, SEE DETAIL.PROPERTY LINECURB AND GUTTER-SEE NOTES (T.O.) TIP OUTGUTTER WHERE APPLICABLE-SEE PLANHEAVY DUTY BITUMINOUS PAVEMENT (IFAPPLICABLE). SEE GEOTECHNICAL REPORT FORAGGREGATE BASE & WEAR COURSE DEPTH, SEEDETAIL.CONSTRUCTION LIMITSTOGross Site Area: 27.37 Ac.Existing Wetland Area: 3.72 Ac.*Net Developable Area: 23.65 Ac.(Lots & Local Roads, Ponds)Zoning:Existing Zoning: Ag Agriculture2040 Land Use Guide: Low Density Residential(2-4 u/a)Proposed Zoning/ Land Use:PUDOverall Residential Units:61 lots (2.58 u/a)SF lots, 70' wide.24 lotsVilla SF lots, 50' wide.37 lotsCITY OF PRIOR LAKE SITE SPECIFIC NOTES:1.RESERVED FOR CITY SPECIFIC REMOVAL NOTES.TYPICAL 53' VILLA HOME LOT INFORMATION:LOT NUMBERPAD SIZELOT LINED & U EASEMENT10' FRONT & REAR5' SIDE (TYP.)BUILDING SETBACK25' FRONT25' REAR7.5' SIDES/ 25' SIDE ROW38'x60'PADROW LINECURB LINEMINIMUM LOT SIZE:6,360 SFTYPICAL 70' SF HOME LOT INFORMATION:LOT NUMBERPAD SIZELOT LINED & U EASEMENT10' FRONT & REAR5' SIDE (TYP.)BUILDING SETBACK25' FRONT25' REAR7.5' SIDES, TYP/ 25' SIDE ROW45'x55'PADROW LINECURB LINEMINIMUM LOT SIZE:8,125 SF Wildflower Way NE 138th S t . NEMeridian Way NEApex WayLupine Trail NE 138th St. NEJackson Street NEBLOCK 1OTL. B 8 232221201918 1234BLOCK 3Street "B"Street "C"45679314123456810 112311BLOCK 7BLOCK 517 13127921GHOST PLATFUTURE ROADBLOCK 2OTL. CPOND /INFILTRATIONBASINWETLAND 3LEAST/LOWOHWL=998.10EX 100-YR HWL=998.57PR 100-YR HWL=999.55 EOF=1002.00WETLAND 1LEAST/LOWOHWL=1012.20EX 100-YR HWL=1014.24PR 100-YR HWL=1014.11EOF=1015.40FILTRATION BASINHAVEN RIDGE SOUTHINF EL=981.50OUTLET=982.32EX 100-YR HWL=986.61PR 100-YR HWL=986.99EOF=986.60WETLAND 2LEAST/LOWOHWL=1011.90EX 100-YR HWL=1015.45PR 100-YR HWL=1014.46EOF=1014.50WETLAND 4LEAST/LOWOHWL=1000.00EX 100-YR HWL=1002.32PR 100-YR HWL=1002.17EOF=1002.20WETLAND 7LEAST/LOWOHWL=979.42EX 100-YR HWL=985.12PR 100-YR HWL=985.94EOF=990.60BMP2INF EL=996.50OUTLET=998.10100-YR HWL=999.50EOF=1002.0065431 852 Exist.OTL. D7BLOCK 67 8 9 1 0 5 3 2 BLOCK 4 6 1 4BLOCK 591516BLOCK 1BLOCK 3OTL. ALupine Trail NE 10EOF1003.00EOF1002.20EOF1009.70EOF1015.40EOF994.40EOF986.60EOF990.60MAINTENANCE ACCESS MAINTENANCE ACCESSEOF999.00EOF1014.50EOF1003.13EOF1000.40EOF994.40EOF1014.06 ST-1ST-3ST-2ST-7ST-6ST-8ST-4ST-5ST-9ST-10EL=994.0CL, SP-SMEL=1008.2OL, CL,SP-SMEL=1003.9OL, CL,SMEL=993.4CL, SMEL=1019.6SM,EL=1007.9CL, SP,SMEL=1004.2CL, SPEL=1017.4CL, SP-SMSC-SMEL=1002.1CL, SPEL=1007.5CL, SMCivil Engineering Surveying Landscape Architecture4931 W. 35th Street, Suite 200St. Louis Park, MN 55416civilsitegroup.com 612-615-0060THE VILLAS AT CREST WOODS PRIOR LAKE, MINNESOTA 7455 FRANCE AVENUE SOUTH, SUITE 351, EDINA, MN 55435 PRIOR LAKE DEVELOPMENT, LLC PROJECT ISSUE/SUBMITTAL SUMMARYDATEDESCRIPTION............PROJECT NUMBER:203026.15.21CITY RESUBMITTAL8.18.20CITY RESUBMITTAL........3-15-21PRELIMINARY PLAT/ PUD SUBMITTALDRAWN BY:REVIEWED BY:KTMP..............COPYRIGHT CIVIL SITE GROUP INC.cP R E L I M I N A R Y : N O T F O R C O N S T R U C T I O N44263Matthew R. PavekLICENSE NO.DATEI HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION, OR REPORT WASPREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULYLICENSED PROFESSIONAL ENGINEERUNDER THE LAWS OF THE STATE OFMINNESOTA.6-15-21REVISION SUMMARYDATEDESCRIPTIONC3.0OVERALLGRADING PLAN............01" = 100'-0"100'-0"50'-0"NKnow what'sbelow.before you dig.CallR1.SEE SITE PLAN FOR HORIZONTAL LAYOUT & GENERAL GRADING NOTES.2.THE CONTRACTOR SHALL COMPLETE THE SITE GRADING CONSTRUCTION (INCLUDING BUT NOT LIMITED TO SITEPREPARATION, SOIL CORRECTION, EXCAVATION, EMBANKMENT, ETC.) IN ACCORDANCE WITH THE REQUIREMENTS OF THEOWNER'S SOILS ENGINEER. ALL SOIL TESTING SHALL BE COMPLETED BY THE OWNER'S SOILS ENGINEER. THE CONTRACTORSHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED SOIL TESTS AND INSPECTIONS WITH THE SOILS ENGINEER.3.GRADING AND EXCAVATION ACTIVITIES SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL POLLUTION DISCHARGEELIMINATION SYSTEM (NPDES) PERMIT REQUIREMENTS & PERMIT REQUIREMENTS OF THE CITY.4.ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTACT "GOPHER STATE ONE CALL" (651-454-0002 OR800-252-1166) FOR UTILITY LOCATIONS, 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACEANY UTILITIES THAT ARE DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER.5.PROPOSED SPOT GRADES ARE FLOW-LINE FINISHED GRADE ELEVATIONS, UNLESS OTHERWISE NOTED.6.GRADES OF WALKS SHALL BE INSTALLED WITH 5% MAX. LONGITUDINAL SLOPE AND 1% MIN. AND 2% MAX. CROSS SLOPE,UNLESS OTHERWISE NOTED.7.PROPOSED SLOPES SHALL NOT EXCEED 3:1 UNLESS INDICATED OTHERWISE ON THE DRAWINGS. MAXIMUM SLOPES INMAINTAINED AREAS IS 4:18.PROPOSED RETAINING WALLS, FREESTANDING WALLS, OR COMBINATION OF WALL TYPES GREATER THAN 4' IN HEIGHTSHALL BE DESIGNED AND ENGINEERED BY A REGISTERED RETAINING WALL ENGINEER. DESIGN DRAWINGS SHALL BESUBMITTED FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION.9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF GRADE STAKES THROUGHOUT THE DURATION OFCONSTRUCTION TO ESTABLISH PROPER GRADES. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR A FINAL FIELDCHECK OF FINISHED GRADES ACCEPTABLE TO THE ENGINEER/LANDSCAPE ARCHITECT PRIOR TO TOPSOIL AND SODDINGACTIVITIES.10.IF EXCESS OR SHORTAGE OF SOIL MATERIAL EXISTS, THE CONTRACTOR SHALL TRANSPORT ALL EXCESS SOIL MATERIAL OFFTHE SITE TO AN AREA SELECTED BY THE CONTRACTOR, OR IMPORT SUITABLE MATERIAL TO THE SITE.11.EXCAVATE TOPSOIL FROM AREAS TO BE FURTHER EXCAVATED OR REGRADED AND STOCKPILE IN AREAS DESIGNATED ONTHE SITE. THE CONTRACTOR SHALL SALVAGE ENOUGH TOPSOIL FOR RESPREADING ON THE SITE AS SPECIFIED. EXCESSTOPSOIL SHALL BE PLACED IN EMBANKMENT AREAS, OUTSIDE OF BUILDING PADS, ROADWAYS AND PARKING AREAS. THECONTRACTOR SHALL SUBCUT CUT AREAS, WHERE TURF IS TO BE ESTABLISHED, TO A DEPTH OF 6 INCHES. RESPREADTOPSOIL IN AREAS WHERE TURF IS TO BE ESTABLISHED TO A MINIMUM DEPTH OF 6 INCHES.12.FINISHED GRADING SHALL BE COMPLETED. THE CONTRACTOR SHALL UNIFORMLY GRADE AREAS WITHIN LIMITS OF GRADING,INCLUDING ADJACENT TRANSITION AREAS. PROVIDE A SMOOTH FINISHED SURFACE WITHIN SPECIFIED TOLERANCES, WITHUNIFORM LEVELS OR SLOPES BETWEEN POINTS WHERE ELEVATIONS ARE SHOWN, OR BETWEEN SUCH POINTS ANDEXISTING GRADES. AREAS THAT HAVE BEEN FINISH GRADED SHALL BE PROTECTED FROM SUBSEQUENT CONSTRUCTIONOPERATIONS, TRAFFIC AND EROSION. REPAIR ALL AREAS THAT HAVE BECOME RUTTED BY TRAFFIC OR ERODED BY WATEROR HAS SETTLED BELOW THE CORRECT GRADE. ALL AREAS DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BERESTORED TO EQUAL OR BETTER THAN ORIGINAL CONDITION OR TO THE REQUIREMENTS OF THE NEW WORK.13.PRIOR TO PLACEMENT OF THE AGGREGATE BASE, A TEST ROLL WILL BE REQUIRED ON THE STREET AND/OR PARKING AREASUBGRADE. THE CONTRACTOR SHALL PROVIDE A LOADED TANDEM AXLE TRUCK WITH A GROSS WEIGHT OF 25 TONS. THETEST ROLLING SHALL BE AT THE DIRECTION OF THE SOILS ENGINEER AND SHALL BE COMPLETED IN AREAS AS DIRECTED BYTHE SOILS ENGINEER. THE SOILS ENGINEER SHALL DETERMINE WHICH SECTIONS OF THE STREET OR PARKING AREA AREUNSTABLE. CORRECTION OF THE SUBGRADE SOILS SHALL BE COMPLETED IN ACCORDANCE WITH THE REQUIREMENTS OFTHE SOILS ENGINEER. NO TEST ROLL SHALL OCCUR WITHIN 10' OF ANY UNDERGROUND STORM RETENTION/DETENTIONSYSTEMS.14. TOLERANCES14.1.THE BUILDING SUBGRADE FINISHED SURFACE ELEVATION SHALL NOT VARY BY MORE THAN 0.30 FOOT ABOVE, OR 0.30FOOT BELOW, THE PRESCRIBED ELEVATION AT ANY POINT WHERE MEASUREMENT IS MADE.14.2.THE STREET OR PARKING AREA SUBGRADE FINISHED SURFACE ELEVATION SHALL NOT VARY BY MORE THAN 0.05 FOOTABOVE, OR 0.10 FOOT BELOW, THE PRESCRIBED ELEVATION OF ANY POINT WHERE MEASUREMENT IS MADE.14.3.AREAS WHICH ARE TO RECEIVE TOPSOIL SHALL BE GRADED TO WITHIN 0.30 FOOT ABOVE OR BELOW THE REQUIREDELEVATION, UNLESS DIRECTED OTHERWISE BY THE ENGINEER.14.4.TOPSOIL SHALL BE GRADED TO PLUS OR MINUS 1/2 INCH OF THE SPECIFIED THICKNESS.15.MAINTENANCE15.1.THE CONTRACTOR SHALL PROTECT NEWLY GRADED AREAS FROM TRAFFIC AND EROSION, AND KEEP AREA FREE OFTRASH AND DEBRIS.15.2.CONTRACTOR SHALL REPAIR AND REESTABLISH GRADES IN SETTLED, ERODED AND RUTTED AREAS TO SPECIFIEDTOLERANCES. DURING THE CONSTRUCTION, IF REQUIRED, AND DURING THE WARRANTY PERIOD, ERODED AREASWHERE TURF IS TO BE ESTABLISHED SHALL BE RESEEDED AND MULCHED.15.3.WHERE COMPLETED COMPACTED AREAS ARE DISTURBED BY SUBSEQUENT CONSTRUCTION OPERATIONS OR ADVERSEWEATHER, CONTRACTOR SHALL SCARIFY, SURFACE, RESHAPE, AND COMPACT TO REQUIRED DENSITY PRIOR TOFURTHER CONSTRUCTION.GENERAL GRADING NOTES:1.0' CONTOUR ELEVATION INTERVALGRADING PLAN LEGEND:SPOT GRADE ELEVATION GUTTERSPOT GRADE ELEVATION TOP OF CURBSPOT GRADE ELEVATION BOTTOM OF STAIRS/TOP OF STAIRSSEE SWPPP ON SHEETS SW1.0 - SW1.5EROSION CONTROL NOTES:EX. 1' CONTOUR ELEVATION INTERVALSPOT GRADE ELEVATION (GUTTER/FLOW LINEUNLESS OTHERWISE NOTED)CURB AND GUTTER (T.O = TIP OUT)EMERGENCY OVERFLOWEOF=1135.52TOSPOT GRADE ELEVATION MATCH EXISTINGGRADE BREAK - HIGH POINTSCITY OF PRIOR LAKE GRADING NOTES:1.RETAINING WALLS OVER 4' IN HEIGHT WILL REQUIRED A PERMIT FROM THE CITY,BE DESIGNED BY A MN LICENSED REGISTERED ENGINEER, AND HAVE A FENCECONSTRUCTED ON TOP OF THE WALLS. 111415Wildflower Way NE 138th S t . NEMeridian Way NEApex WayLupine Trail NE 138th St. NEJackson Street NEBLOCK 1OTL. B 8 232221201918 1234BLOCK 3Street "B"Street "C"45679314123456810 112311BLOCK 7BLOCK 517 13127921BLOCK 2OTL. CPOND /INFILTRATIONBASINWETLAND 3LEAST/LOWOHWL=998.10EX 100-YR HWL=998.57PR 100-YR HWL=999.55 EOF=1002.00CONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTION LIMITS (TYP.)WETLAND 1LEAST/LOWOHWL=1012.20EX 100-YR HWL=1014.24PR 100-YR HWL=1014.11EOF=1015.40FILTRATION BASINHAVEN RIDGE SOUTHINF EL=981.50OUTLET=982.32EX 100-YR HWL=986.61PR 100-YR HWL=986.99EOF=986.60WETLAND 2LEAST/LOWOHWL=1011.90EX 100-YR HWL=1015.45PR 100-YR HWL=1014.46EOF=1014.50WETLAND 4LEAST/LOWOHWL=1000.00EX 100-YR HWL=1002.32PR 100-YR HWL=1002.17EOF=1002.20WETLAND 7LEAST/LOWOHWL=979.42EX 100-YR HWL=985.12PR 100-YR HWL=985.94EOF=990.60BMP2INF EL=996.50OUTLET=998.10100-YR HWL=999.50EOF=1002.0065431 852 Exist.OTL. D7BLOCK 67 8 9 1 0 5 3 2 BLOCK 4 6 1 4BLOCK 591516BLOCK 1BLOCK 3OTL. ALupine Trail NE 10Civil Engineering Surveying Landscape Architecture4931 W. 35th Street, Suite 200St. Louis Park, MN 55416civilsitegroup.com 612-615-0060THE VILLAS AT CREST WOODS PRIOR LAKE, MINNESOTA 7455 FRANCE AVENUE SOUTH, SUITE 351, EDINA, MN 55435 PRIOR LAKE DEVELOPMENT, LLC PROJECT ISSUE/SUBMITTAL SUMMARYDATEDESCRIPTION............PROJECT NUMBER:203026.15.21CITY RESUBMITTAL8.18.20CITY RESUBMITTAL........3-15-21PRELIMINARY PLAT/ PUD SUBMITTALDRAWN BY:REVIEWED BY:KTMP..............COPYRIGHT CIVIL SITE GROUP INC.cP R E L I M I N A R Y : N O T F O R C O N S T R U C T I O N44263Matthew R. PavekLICENSE NO.DATEI HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION, OR REPORT WASPREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULYLICENSED PROFESSIONAL ENGINEERUNDER THE LAWS OF THE STATE OFMINNESOTA.6-15-21REVISION SUMMARYDATEDESCRIPTIONC4.0OVERALL UTILITY PLAN............GENERAL UTILITY NOTES:UTILITY LEGEND:CITY OF PRIOR LAKE UTILITY NOTES:1.10 GAUGE TRACER WIRES FOR THE SANITARY SEWER SERVICES AREAREQUIRED FOR LOCATING PURPOSES AND SHALL BE INSTALLED INACCORDANCE WITH THE MN RURAL WATER TRACER WIRE SPECIFICATIONS.THE TRACER WIRE SHOULD CONNECT TO A TRACER WIRE ACCESS BOX AT THEEASEMENT (SEE PLATE #401.)01" = 100'-0"100'-0"50'-0"NKnow what'sbelow.before you dig.CallRCATCH BASINGATE VALVE AND VALVE BOXSANITARY SEWERSTORM SEWERWATER MAINPROPOSED FIRE HYDRANTMANHOLEFES AND RIP RAP1.ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTACT "GOPHER STATE ONE CALL" (651-454-0002 OR800-252-1166) FOR UTILITY LOCATIONS, 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACEANY UTILITIES THAT ARE DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER.2. SEE SITE PLAN FOR HORIZONTAL DIMENSIONS AND LAYOUT.3. CONTRACTOR SHALL FIELD VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIORTO CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF DISCREPANCIES OR VARIATIONSFROM THE PLANS.4. UTILITY INSTALLATION SHALL CONFORM TO THE CURRENT EDITION OF "STANDARD SPECIFICATIONS FOR WATER MAIN ANDSERVICE LINE INSTALLATION" AND "SANITARY SEWER AND STORM SEWER INSTALLATION" AS PREPARED BY THE CITYENGINEERS ASSOCIATION OF MINNESOTA (CEAM), AND SHALL CONFORM WITH THE REQUIREMENTS OF THE CITY AND THEPROJECT SPECIFICATIONS.5. CASTINGS SHALL BE SALVAGED FROM STRUCTURE REMOVALS AND RE-USED OR PLACED AT THE DIRECTION OF THE OWNER.6. ALL WATER PIPE SHALL BE CLASS 52 DUCTILE IRON PIPE (DIP) AWWA C151, ASME B16.4, AWWA C110, AWWA C153 UNLESS OTHERWISE NOTED.7. ALL SANITARY SEWER SHALL BE SDR 26 POLYVINYL CHLORIDE (PVC) ASTM D3034 & F679, OR SCH 40 ASTM D1785, 2665, ASTMF794, 1866) UNLESS OTHERWISE NOTED.8. ALL STORM SEWER PIPE SHALL BE HDPE ASTM F714 & F2306 WITH ASTM D3212 SPEC FITTINGS UNLESS OTHERWISE NOTED.9. PIPE LENGTHS SHOWN ARE FROM CENTER TO CENTER OF STRUCTURE OR TO END OF FLARED END SECTION.10. UTILITIES ON THE PLAN ARE SHOWN TO WITHIN 5' OF THE BUILDING FOOTPRINT. THE CONTRACTOR IS ULTIMATELYRESPONSIBLE FOR THE FINAL CONNECTION TO BUILDING LINES. COORDINATE WITH ARCHITECTURAL AND MECHANICALPLANS.11. CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCH BASINS IN GUTTERS SHALL BESUMPED 0.15 FEET PER DETAILS. RIM ELEVATIONS SHOWN ON THIS PLAN DO NOT REFLECT SUMPED ELEVATIONS.12. ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB UNLESS OTHERWISE NOTED.13. HYDRANT TYPE, VALVE, AND CONNECTION SHALL BE IN ACCORDANCE WITH CITY REQUIREMENTS. HYDRANT EXTENSIONS AREINCIDENTAL.14. A MINIMUM OF 8 FEET OF COVER IS REQUIRED OVER ALL WATERMAIN, UNLESS OTHERWISE NOTED. EXTRA DEPTH MAY BEREQUIRED TO MAINTAIN A MINIMUM OF 18" VERTICAL SEPARATION TO SANITARY OR STORM SEWER LINES. EXTRA DEPTHWATERMAIN IS INCIDENTAL.15. A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FOR ALLUTILITIES, UNLESS OTHERWISE NOTED.16. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE IN ACCORDANCE WITH CITY STANDARDS AND COORDINATED WITH THECITY PRIOR TO CONSTRUCTION.17.CONNECTIONS TO EXISTING STRUCTURES SHALL BE CORE-DRILLED.18. COORDINATE LOCATIONS AND SIZES OF SERVICE CONNECTIONS WITH THE MECHANICAL DRAWINGS.19. COORDINATE INSTALLATION AND SCHEDULING OF THE INSTALLATION OF UTILITIES WITH ADJACENT CONTRACTORS AND CITYSTAFF.20. ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. ALL PAVEMENTCONNECTIONS SHALL BE SAWCUT. ALL TRAFFIC CONTROLS SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BEESTABLISHED PER THE REQUIREMENTS OF THE MINNESOTA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MMUTCD)AND THE CITY. THIS SHALL INCLUDE BUT NOT BE LIMITED TO SIGNAGE, BARRICADES, FLASHERS, AND FLAGGERS AS NEEDED.ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. NO ROAD CLOSURES SHALL BE PERMITTED WITHOUTAPPROVAL BY THE CITY.21. ALL STRUCTURES, PUBLIC AND PRIVATE, SHALL BE ADJUSTED TO PROPOSED GRADES WHERE REQUIRED. THEREQUIREMENTS OF ALL OWNERS MUST BE COMPLIED WITH. STRUCTURES BEING RESET TO PAVED AREAS MUST MEETOWNERS REQUIREMENTS FOR TRAFFIC LOADING.22. CONTRACTOR SHALL COORDINATE ALL WORK WITH PRIVATE UTILITY COMPANIES.23. CONTRACTOR SHALL COORDINATE CONNECTION OF IRRIGATION SERVICE TO UTILITIES. COORDINATE THE INSTALLATION OFIRRIGATION SLEEVES NECESSARY AS TO NOT IMPACT INSTALLATION OF UTILITIES.24. CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT CONSTRUCTION AND SUBMIT THESE PLANS TO ENGINEERUPON COMPLETION OF WORK.25.ALL JOINTS AND CONNECTIONS IN STORM SEWER SYSTEM SHALL BE GASTIGHT OR WATERTIGHT. APPROVED RESILIENTRUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCHBASINS, OR OTHERSTRUCTURES.26.ALL PORTIONS OF THE STORM SEWER SYSTEM LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER SERVICE LINE MUST BETESTED IN ACCORDANCE WITH MN RULES, CHAPTER 4714, SECTION 1109.0.27.FOR ALL SITES LOCATED IN CLAY SOIL AREAS, DRAIN TILE MUST BE INSTALLED AT ALL LOW POINT CATCH BASINS 25' IN EACHDIRECTION. SEE PLAN AND DETAIL. INSTALL LOW POINT DRAIN TILE PER PLANS AND GEOTECHNICAL REPORTRECOMMENDATIONS AND REQUIREMENTS.SITE SPECIFIC UTILITY NOTES:1.TREES AND LIGHT POLES ARE TO BE CONSTRUCTED ABOVE THE UNDERGROUNDFILTRATION BASIN IN PARKING LOT ISLANDS. GAPS IN THE PIPE SYSTEM ARE TOBE SHOWN ON FINAL SHOP DRAWINGS. Wildflower Way NE 138th S t . NEMeridian Way NEApex WayLupine Trail NE 138th St. NEJackson Street NE8 232221201918 1234Street "B"Street "C"45679314123456810 11231117 13127921POND /INFILTRATIONBASINCONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTIONLIMITS (TYP.)CONSTRUCTION LIMITS (TYP.)65431 852 Exist.7 7 8 9 1 0 5 3 2 6 1 49 1516Lupine Trail NE 10SEED TYPE 1 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 1 (TYP.)SEED TYPE 1 (TYP.)SEED TYPE 1 (TYP.)SEED TYPE 1 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 2 (TYP.)SEED TYPE 2 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 2 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 3 (TYP.)SEED TYPE 3 (TYP.)8 - RP3 - CS3 - BS6 - WP5 - RP4 - WP6 - BS3 - CS9 - RP9 - WP2 - NS5 - CS5 - BS4 - BS5 - NS5 - CS5 - BS2 - NS3 - HA20 - RO14 - RO14 - RO10- SM10 - SM7 - SM10 - SM11 - SM20 - SO19 - RM4 - HA4 - BA9 - CO9 - CO3 - HA5 - CO5 - CO8 - RM2 - RM14 - RM7 - BA4 - BA8 - BA1 - BA3 - BASEED TYPE 2 (TYP.)SEED TYPE 2 (TYP.)SEED TYPE 2 (TYP.)SEED TYPE 2 (TYP.)SEED TYPE 3 (TYP.)REVISION SUMMARYDATEDESCRIPTIONL1.0OVERALL LANDSCAPEPLAN............Civil Engineering Surveying Landscape Architecture4931 W. 35th Street, Suite 200St. Louis Park, MN 55416civilsitegroup.com 612-615-0060THE VILLAS AT CREST WOODS PRIOR LAKE, MINNESOTA 7455 FRANCE AVENUE SOUTH, SUITE 351, EDINA, MN 55435 PRIOR LAKE DEVELOPMENT, LLC PROJECT ISSUE/SUBMITTAL SUMMARYDATEDESCRIPTION............PROJECT NUMBER:203026.15.21CITY RESUBMITTAL8.18.20CITY RESUBMITTAL........3-15-21PRELIMINARY PLAT/ PUD SUBMITTALDRAWN BY:REVIEWED BY:KTMP..............COPYRIGHT CIVIL SITE GROUP INC.cP R E L I M I N A R Y : N O T F O R C O N S T R U C T I O N26980KEVIN TEPPENLICENSE NO.DATEI HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION, OR REPORT WASPREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULYLICENSED LANDSCAPE ARCHITECT UNDERTHE LAWS OF THE STATE OF MINNESOTA.6-15-2101" = 100'-0"100'-0"50'-0"NKnow what'sbelow.before you dig.CallRTREES PER LOT: 2. TOTAL LOTS: 60TREES REQUIRED:120REPLACEMENT TREES REQUIRED: 55BUFFERYARD TREES REQUIRED: 77TOTAL TREES REQUIRED:252TOTAL TREES PROVIDED:332REQUIRED LANDSCAPE CALCULATIONSLAWN - SOD, SALT TOLLERANTSEED TYPE 1 - MNDOT 33-261 STORMWATER SOUTH &WEST, PER MNDOT SEEDING MANUALSPECIFICATIONS (2014)SEED TYPE 2 - MNDOT 35-221 DRY PRAIRIE, PERMNDOT SEEDING MANUAL SPECIFICATIONS (2014)PROPOSED EVERGREEN TREE SYMBOLS - SEE PLANTSCHEDULE AND PLAN FOR SPECIES AND PLANTING SIZESPROPOSED CANOPY TREE SYMBOLS - SEE PLANT SCHEDULEAND PLAN FOR SPECIES AND PLANTING SIZESLEGENDSEED TYPE 3 - MNDOT 25-131 TURF, PER MNDOTSEEDING MANUAL SPECIFICATIONS (2014)LANDSCAPE NOTES:1.WHERE SHOWN, SHRUB & PERENNIAL BEDS SHALL BE MULCHED WITH 4" DEPTH (MINIMUM AFTER INSTALLATION AND/OR TOP DRESSING OPERATIONS) OFSHREDDED HARDWOOD MULCH.2.ALL TREES SHALL BE MULCHED WITH SHREDDED HARDWOOD MULCH TO OUTER EDGE OF SAUCER OR TO EDGE OF PLANTING BED, IF APPLICABLE. ALLMULCH SHALL BE KEPT WITHIN A MINIMUM OF 2" FROM TREE TRUNK.3.PLANT MATERIALS SHALL CONFORM WITH THE AMERICAN ASSOCIATION OF NURSERYMEN STANDARDS AND SHALL BE OF HARDY STOCK, FREE FROMDISEASE, DAMAGE AND DISFIGURATION. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING PLUMPNESS OF PLANT MATERIAL FOR DURATION OFACCEPTANCE PERIOD.4.UPON DISCOVERY OF A DISCREPANCY BETWEEN THE QUANTITY OF PLANTS SHOWN ON THE SCHEDULE AND THE QUANTITY SHOWN ON THE PLAN, THEPLAN SHALL GOVERN.5.CONDITION OF VEGETATION SHALL BE MONITORED BY THE LANDSCAPE ARCHITECT THROUGHOUT THE DURATION OF THE CONTRACT. LANDSCAPEMATERIALS PART OF THE CONTRACT SHALL BE WARRANTED FOR TWO (2) FULL GROWING SEASONS FROM SUBSTANTIAL COMPLETION DATE.6.ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES SHALL RECEIVE 4" LAYER TOPSOIL AND SOD AS SPECIFIED UNLESS OTHERWISE NOTED ON THEDRAWINGS.7.ALL PLANT MATERIALS SHALL BE WATERED AND MAINTAINED UNTIL ACCEPTANCE.8.REPAIR AT NO COST TO OWNER ALL DAMAGE RESULTING FROM LANDSCAPE CONTRACTOR'S ACTIVITIES.9.SWEEP AND MAINTAIN ALL PAVED SURFACES FREE OF DEBRIS GENERATED FROM LANDSCAPE CONTRACTOR'S ACTIVITIES.SHREDDED HARDWOOD MULCH (UNDER TREES)THREE TIMES WIDTHOF ROOTBALLDECIDUOUS & CONIFEROUS TREE PLANTINGN T SPRUNE AS FIELD DIRECTED BY THE LANDSCAPEARCHITECT TO IMPROVE APPEARANCE (RETAINNORMAL TREE SHAPE)THREE 2"X4"X8' WOODEN STAKES, STAINED BROWNWITH TWO STRANDS OF WIRE TWISTED TOGETHER.STAKES SHALL BE PLACED AT 120° TO ONE ANOTHER.WIRE SHALL BE THREADED THROUGH NYLONSTRAPPING WITH GROMMETS. ALTERNATE STABILIZINGMETHODS MAY BE PROPOSED BY CONTRACTOR.TRUNK FLARE JUNCTION: PLANT TREE 1"-2" ABOVEEXISTING GRADEMULCH TO OUTER EDGE OF SAUCER OR TO EDGE OFPLANTING BED, IF APPLICABLE. ROCK OR ORGANICMULCH, SEE GENERAL LANDSCAPE NOTES AND PLANNOTES FOR MULCH TYPE. KEEP MULCH MIN. 2" FROMPLANT TRUNKEXISTING GRADECUT AND REMOVE BURLAP FROM TOP 1/3 OF ROOTBALL. IF NON-BIODEGRADABLE, REMOVE COMPLETELYSLOPE SIDES OF HOLE OR VERTICAL SIDES AT EDGE OFPLANTING BEDBACKFILL AS SPECIFIEDCOMPACT BOTTOM OF PIT, TYP.RULE OF THUMB - MODIFY EXCAVATION BASED ONLOCATION OF PLANT MATERIAL AND DESIGN OF BEDSOR OVERALL PLANT PLACEMENT1PLANT SCHEDULE - ENTIRE SITESYMQUANT.COMMON NAMEBOTANICAL NAMESIZEROOTCOMMENTSDECIDUOUS TREESSM48SUGAR MAPLEAcer saccharum2.5" CAL.B&BSTRAIGHT LEADER. FULL FORMRM43PRESIDENTIAL GOLD GINKOGinko biloba "The President"2.5" CAL.B&BSTRAIGHT LEADER. FULL FORMHA10HACKBERRYCeltis occidentalis2.5" CAL.B&BSTRAIGHT LEADER. FULL FORMBA27BASSWOODTilia americana2.5" CAL.B&BSTRAIGHT LEADER. FULL FORMCO28COFFEETREEGymnocladus dioicus2.5" CAL.B&BSTRAIGHT LEADER. FULL FORMSO22SWAMP WHITE OAKQuercus bicolor2.5" CAL.B&BSTRAIGHT LEADER. FULL FORMRO48RED OAKQuercus rubrum2.5" CAL.B&BSTRAIGHT LEADER. FULL FORM226TOTAL DECIDUOUS TREESEVERGREEN TREESRP22RED PINEPinus resinosa6' ht.B&BSTRAIGHT LEADER. FULL FORMWP19WHITE PINEPinus strobus6' ht.B&BSTRAIGHT LEADER. FULL FORMBS28BLACK HILLS SPRUCEPicea glauca "Densata"6' ht.B&BSTRAIGHT LEADER. FULL FORMCS28COLORADO SPRUCEPicea pungens 'Glauca'6' ht.B&BSTRAIGHT LEADER. FULL FORMNS9CONCOLOR FIRAbies concolor6' ht.B&BSTRAIGHT LEADER. FULL FORM106TOTAL EVERGREEN TREES L:\21 FILES\21 SUBDIVISIONS\PRELIMINARY PLAT\Villas at Crest Woods PDEV21-000008\00 PC Report\Villas at Crest Woods Prelim Plat Eng Memo 070921.docx 701 XENIA AVENUE S | SUITE 300 | MINNEAPOLIS, MN | 55416 | 763.541.4800 | WSBENG.COM Memorandum To: Nick Monserud, Assistant City Engineer Pete Young, Water Resources Engineer From: Kris Keller, Laura Kivisto, Dustin Simonson, Chuck Rickert - WSB Date: July 5, 2021 Re: Villas at Crest Woods WSB Project No. 10704-000 We have completed our preliminary plat review of the civil and stormwater plans submitted for the Villas at Crest Woods on June 15, 2021 as prepared by Civil Site Group. The following documents were received: · Preliminary Plat Plans (VILLAS AT CREST WOODS-CITY RESUBMITTAL 6-15-21.pdf) · Preliminary Plat (20302-NHH Prior Lake-PRELIMINARY PLAT-Pre Plat-Combined-6-14- 2021.pdf) · Stormwater Report (00 - CSG Villas at Crest Woods 20302 STORMWATER REPORT - 3-15-2021.pdf) · Geotechnical Evaluation Report (Geotechnical Evaluation Report - Summit Preserve Continuation, B1908052.pdf) · Trip Generation Study (Trip Generation 3-14-21 Prior Lake.doc) · Alta Survey (ALTA Chadwick (Summit Preserve) 8-13-2019.pdf) · Boundary Topographic Survey (20302-NHH-Prior Lake-3-19-2021.pdf) Comments are provided within this Memorandum and in the corresponding redlined plan set. Please note that not all comments within the plan set are in the Memorandum. We have the following comments with regards to engineering and stormwater management. Greyed out comments have been addressed. Red comments are new to this review. Comments in standard text still apply. General 1. Submit for and provide copies to the City of all required permits from regulatory agencies (MCES, Minnesota Pollution Control Agency, Minnesota Department of Health, County, etc.) 2. An NPDES permit is required as the site exceeds 1 acre of disturbance. 3. Provide a memo along with your plan revisions which responds to the provided comments. Plat 1. Revise Block 6 lots to meet City R-1 size requirements 2. Provide drainage and utility easements for all drainage swales that convey water from one lot across another Villas at Crest Woods July 9, 2021 Page 2 a. The width of the easement should be a minimum of 10’ with at least 5' on either side of the center of the swale 3. Please note which Outlots will be dedicated to the City and which will be privately owned. a. Extend lot lines to remove all outlots other than Outlot F which will be deeded to the City b. Provide drainage and utility easements over all public utilities and stormwater management facilities on private property. 4. Provide drainage and utility easements for all public utilities running across private property. a. The width of the easement should be at least two times the greatest depth of the utility with a minimum of 20' centered on the utility 5. Remove the three Block 7 lots along 138th Street. The lots for Block 7 are dangerously close to the turn lane tapers and the intersection with 138th St and Crest Ave. This would be exasperated with reverse movements coming out from the driveways. The traffic engineer recommends removing them from the segment altogether. Streets/Trails 1. Based on the proposed site plan the anticipated traffic generation would be 651 vehicle per day (vpd), 52 AM peak hour trips and 69 PM peak hour trips, assuming 69 single family lots on the site. This is consistent with the Trip Generation memorandum provided by Swing Traffic Solutions (March 14, 2021). 2. Access for the site is proposed using the extension of 138th Street (east/west) and Johnson Street (north/south). Johnson Street is a proposed local city street and 138th Street is a proposed Major Collector roadway in the City’s 2040 Comprehensive Plan. The design included on the site plan conforms to a local street standards (66ft ROW, 32ft width) and Collector Street standards (66ft ROW, 36ft wide). 3. 138th Street provides access to the regional transportation system at Crest Avenue (CSAH 18). Crest Avenue (CSAH 18) is a Scott County roadway classified as an A-Minor Arterial Expander in the County’s 2040 Transportation Plan, however it has been identified as a potential turnback to the City and reclassification as a Collector roadway. The existing ADT is 5600vpd and projected in 2040 at 10,700vpd. 4. The proposed site plan shows improvements at the Crest Avenue (CSAH 18) and 138th Street intersection of adding a southbound left turn land and northbound right turn lane. The design of these improvements will need to be coordinated with Scott County including the required length of the turn lane bay and the width of the turn lanes. Typically, the turn lane length is 250ft to 300ft and the width is 13ft to 14ft to the face of curb. Include a typical section for the Crest Avenue (CSAH 18) improvements. 5. 138th Street at Crest Avenue (CSAH 18) is proposed to be widened to include four lanes, westbound approaching Crest Avenue (CSAH 18) with a right, through and left and eastbound exiting one through lane. The plan shows the lanes adjacent to the curb at a width of 12ft to back of curb. At a minimum these widths should be 12ft to the face of curb or 13ft to back of curb. The taper to the turn lanes should be a minimum of 10:1. A typical section should be provided for the 138th Street Improvements (Collector Street). 6. A truck turning template should be provided showing the turning movements from Crest Avenue (CSAH 18) to 138th Street. The eastbound exiting lane appears to be too narrow Villas at Crest Woods July 9, 2021 Page 3 to accommodate these movements. An exhibit should be provided showing the turning radii. 7. The side street approaches to 138th Street should have stop sign control. 8. A sight line analysis should be completed for all intersections including the intersections on 138th Street at Johnson Street and Street at Street A, and on Johnson Street at Street B, Street C, Meridian Way and Apex Way. 9. The final plans should include a signing and pavement marking plan, including at a minimum: size and locations of stop signs, street signs and pedestrian crossing signs, and size type and location of street lane markings and pedestrian crossing striping. 10. Revise cul de sac for Street A to meet City standards for offset spacing (660’) from collectors or higher order streets. 11. Revise 138th St intersection with Crest Ave (CR 18) to match exhibits sent to developer. 12. Flip the driveways from Lot 1 Block 10 and Lot 1 Block 11 away from the intersection. 13. Street Profiles a. Provide street profiles that show the proposed street grades and vertical curves. b. Identify centerlines of connecting streets at intersections in profile views. c. Vertical curves need to meet the minimum required K value (30 for crest curves, 36 for sag curves) for 30 mph. 14. Provide horizontal curve/alignment information for all roads. a. Curves must meet a 30 MPH design speed and shall have a minimum 250’ centerline radius 15. Provide typical sections for all roads a. Include proposed curb types b. Include supporting geotechnical information Stormwater Management 1. Drainage Areas and Modeling a. Verify that there is no stormwater runoff onto the site from the development on the south boundary of the site. b. Label the wetlands and BMPs on the drainage area maps. c. Calculate the time of concentration values in lieu of using a generic value. d. Ensure drainage areas in HydroCAD match the drainage area maps (EX2A). e. Proposed Conditions HydroCAD Model i. Modify the primary outlet from Wetland 2 to match the plans. ii. Modify the EOF elevations in HydroCAD match the elevations on the plans. iii. Add a starting elevation to BMP 1 at the infiltration elevation. Do not include dead storage in the model. Villas at Crest Woods July 9, 2021 Page 4 iv. BMP 2 includes a starting elevation at 998, but infiltration starts at 996 according to the plan set. Modify the model to match the plans. v. Modify the primary outlet from BMP 2 to match the plans. f. Update all HWLs listed on the plans to match HydroCAD. 2. Rate Control a. Because the property is within the Stormwater Management Overlay District #1, prescriptive rate control of 0.25 cfs/net acre discharge from the site is the maximum allowable discharge for all storm events. Please provide an analysis showing that the site meets this requirement. i. Verify that the existing County storm system elevations will allow for redirecting the proposed pond/infiltration area in the southwest corner to the existing County/City storm system to the south. 1. This will allow for the removal of the long run of storm sewer leading out of Wetland 3 to the north. 2. Adjust rate control to maintain sufficient capacity in the existing system particularly at the storm sewer structure on the southeast corner of Crest Ave and 140th Street. b. Please provide an analysis without available wetland storage to determine if wetland storage is used to meet rate control requirements. If wetlands are used for rate control, show that the wetlands are eligible based on the requirements of Section Six in the Public Works Design Manual. i. If wetlands are used to meet rate control, include columns specifying the tributary area, the required discharge rate (0.05 cfs per tributary acre in the 2-year event, 0.15 cfs per tributary acre in the 10-year event, and existing peak flow for the 100-year event), and the wetland discharge rate in the proposed rate control table for each wetland. 3. Volume Control a. Calculations can be modified to consider 1-inch of runoff from the new impervious surface in lieu of 1.1-inch to meet Prior Lake requirements. b. Routing impervious to BMPs to maximum extent possible. Preliminarily met; consider soil boring comments below. 4. Water Quality a. Preliminarily met; consider soil boring comments below. 5. HWL and EOF requirements a. Low floor elevations shall be at least 2-feet above the HWL. i. Homes near Wetland 2 and Wetland 3 do not meet this requirement. b. Low opening elevations shall be at least 2 feet above the EOF. i. Homes near Wetland 2 and a home near Wetland 3 do not meet this requirement. 6. BMPs a. Please provide a cross section detail of the BMPs. Villas at Crest Woods July 9, 2021 Page 5 b. Soil boring ST-10 shows clay down to 7-feet below the existing surface. Verify that the infiltration BMP 1 will function in this location by including provisions for at least 2 infiltration tests in all proposed infiltration basin locations. In the same manner, provide soil borings at the location of BMP 1. As such, justify the use of a 0.8 in/hr infiltration rate. c. Overlay the tree removals plan on the grading plan to verify that all trees and brush below the controlled water level of the BMPs will be removed. d. Specify maintenance access routes to the BMPs (maximum of 8% grade, maximum of 2% cross slope, and minimum of 10-feet wide). e. Provide Walker Method calculations for appropriate sizing of the permanent pool volume. f. A 10-foot wide aquatic bench is required below the NWL of the pond. g. The invert elevations of pond inlet flared end sections shall match the outlet elevation of the ponds. h. The EOF of a pond should be at least 1 foot higher than the HWL. 7. General a. Clean up the plans so labels do not overlap (particularly the basin names and HWL information). Grading 1. Minimum grading for drainage swales and lot grading shall be 2%. 2. Add the following notes to the grading plan: a. Perimeter/downstream sediment control BMPs shall be installed by the contractor and inspected by the City prior to any site work. b. Slopes greater than or equal to 3:1 shall have approved erosion control BMPs installed immediately after finished grading. 3. Call out the wetland buffer on the grading plan. 4. Show house style detail. 5. Label the driveway grades. 6. Some proposed house elevations do not appear to match adjacent proposed contours (Block 3, etc.) 7. Several blocks have drainage that is directed at the proposed building pads. Revise proposed contours and provide spot elevations between all lots to show drainage directed away from proposed building pads 8. Provide EOF’s for all low points in the streets and greenspaces. 9. Several areas around the perimeter of the development have greater than 3:1 slopes matching with the adjacent existing grades. There is a maximum of 4:1 slopes in maintained areas. 10. Show easements on grading plans a. Provide drainage and utility easements for all drainage swales that convey water from one lot across another 11. Label all streets. Villas at Crest Woods July 9, 2021 Page 6 12. Provide the existing/proposed house elevations and contour information for all adjacent lots to the development in order to best match grades at the development limits. 13. Show storm sewer on grading plans a. Provide all inlet elevations 14. Shift the driveway access for Lot 3 Block 10 from Meridian Way to Lupine Trail. 15. Shift the hydrant out of the driveway for Lot 8 Block 1. 16. Provide additional hydrants along 138th Street east of Jackson Street to maintain fire protection and maximum allowed 450’ spacing. 17. Remove and install the hydrant in the Lupine Trail temporary cul de sac behind the revised back of curb. Utilities 1. Storm Sewer a. Provide rational calculations for the storm sewer. Storm sewer facilities shall be designed for the 10-year 24-hour rainfall event. b. Verify if the storm sewer to the east of the site has adequate capacity to take additional drainage (PR13). c. Storm sewer pipe size and grade shall be greater than or equal to 15-inches in diameter and 0.5% slope. d. Either show the proposed storm sewer on the grading plan (as a background layer) or show the grading on the utility plan to verify that catch basins are included at low points and placed appropriately. e. The maximum spacing between storms sewer structures is 400-feet. Adjust structure spacing to meet requirement. f. Provide the MnDOT standard rip rap detail for the rip rap at the storm sewer outlets. g. Call out an environmental sump structure (3-foot sump) for the last manhole that is road accessible prior to discharging to a waterbody. h. Place catch basins to collect drainage upstream of the intersections (Street B and Jackson Street, Street C and Jackson Street). 2. Sanitary Sewer a. Pipe material for sanitary sewer 16’ to 26’ deep shall be SDR 26 PVC. b. The location, size, type, and class of all sanitary sewer services shall be noted on the plans. c. The maximum depth of the sanitary sewer service at the ROW line shall be 10’ unless documented by a proposed house or building elevation that justifies a deeper service. d. Install service risers where cover over the top of the sanitary main is greater than 12’ or as directed by the engineer. e. Provide 10 gauge tracer wires for the sanitary sewer services for locating purposes and shall be installed in accordance with the MN Rural Water Tracer Villas at Crest Woods July 9, 2021 Page 7 Wire Specification. The tracer wire should connect to a tracer wire access box at the easement (see Plate #401). f. Show the existing and proposed sanitary sewer in plan and profile view, along with other existing and proposed utilities in the construction zone. g. The construction plans for water main and sanitary sewer shall include the lowest elevation of all houses or buildings to be served. h. Verify that the temporary lift station built by M/I Homes has the capacity to accommodate this development. 3. Watermain a. All water fittings should be labeled as to size and type such as bends, tees, plugs, etc. b. The location, size, type, and class of all water services shall be noted on the plans. c. Developers are responsible for constructing the services to the easement line which is approximately 10’ beyond the right of way line. d. Provide a minimum of 18” vertical separation for all watermain crossings with sanitary and storm sewer. Also, other utilities that cross the watermain shall cross at a 90 degree angle, if possible, with the minimum requirement of a 45 degree angle for the crossing. Provide insulation for all storm sewer crossings. e. Show on plans the existing and proposed watermain in plan and profile view along with other existing and proposed utilities in the construction zone. f. Shift the gate valve from the western leg of the intersection of 138th Street and Jackson Street to the southern leg due to the impact for houses along 138th Street and the Street ‘A’ cul-de-sac in the event of a watermain break or maintenance. g. Extend the watermain along 138th Street through and under Crest Avenue (CR 18) with a casing. BMI to verify that the current booster station has the capacity to accommodate this development. h. Identify and address potential utility conflicts where the storm sewer is deeper (greater than 6’) or the sanitary sewer is shallower (less than 10’) with the watermain. i. Fire official to verify fire protection particularly along 138th Street where the hydrants are spaced further apart. j. The hydrant at the south end of Street ‘A’ shall be placed after the last service on the watermain. k. Hydrants should be installed at the high points of the watermain in the profile. l. Shift the storm sewer along 138th Street west of Jackson St/Lupine Trl to the north side of the road i. Keep the watermain on the south side. ii. Remove the sanitary sewer west of Jackson St/Lupine Trl. Villas at Crest Woods July 9, 2021 Page 8 4. General a. Show easements on utility plans b. Provide drainage and utility easements for all public utilities running across private property. i. The width of the easement should be at least two times the greatest depth of the utility with a minimum of 20' centered on the utility c. Label all streets Miscellaneous 1. Utilize current City of Prior Lake Design Manual and Standard Detail Plates 2. Include City Plate #402 for Sanitary Sewer Outside Drop Manhole SWPPP 1. Specify the locations of the temporary sediment basins on the ESC plan, required for all drainage areas greater than 5 acres. 2. Update the SWPPP to be specific to the site including the description of the construction activity, impervious surface, contact information, party responsible for long term maintenance of the system, etc. The current SWPPP appears to be for a different project. 3. Call out inlet protection on all catch basins (CBMH 16A, CBMH 16B). Wetland 1. The development is showing wetland impacts through the removal of smaller wetlands within the site. Wetland impacts will need to be approved under WCA. a. The application for WCA permit has not been submitted to the City for Review. 2. The following applies to the required wetland buffers: a. The site falls within Prior Lake Spring Lake Watershed District. For this site, all wetlands must have minimum buffer width of 20 feet with an average width of 30 feet wide from the delineated wetland edge. No grading is allowed within wetland buffers, with exceptions for pipe outlets and associated riprap, reseeding and soil amendments, grade changes adjacent to approved WCA impacts, and temporary impacts associated with utility installation. b. Change the name of the “Buffer” line to “Wetland Buffer” on all plan sheets to avoid confusion. c. Show a double row of silt fence upgradient of all wetland buffer lines. This is also a requirement of the NPDES general permit. d. Buffers shall be identified within each parcel by permanent monumentation. Monuments shall be required at each parcel line where it crosses a buffer and shall have a maximum spacing of 200 feet along the edge of the buffer. Additional monuments shall be placed as necessary to accurately define the edge of the buffer. Villas at Crest Woods July 9, 2021 Page 9 PLSLWD Rule D – Stormwater Management 1. HydroCAD Modeling Comments a. Runoff should be calculated separately for pervious and impervious areas, instead of using a weighted curve number for each subcatchment. b. Time of concentration should be modeled explicitly for each subcatchment instead of assuming 10 minutes for all subcatchments. c. Entire site is modeled as 75% grass cover in good condition. However, aerial imagery indicates that landcover is largely wooded, which should be modeled with a lower curve number for existing conditions. d. Web soil survey indicates a portion of the site with HSG B soils, which is similarly reflected in soil boring #6. This portion of the site should be modeled as HSG B instead of HSG D. Under proposed conditions, this area should be modeled as HSG C to reflect compaction of soils due to construction. e. Documentation should be provided for the existing infiltration basin to confirm that 0.63 in/hr is an appropriate infiltration rate. f. The overflow elevation for Wetland 1 is not accurate. 2-foot contours indicate the overflow to be between 1018 and 1020, but it is modeled at 1015.4. Other wetland overflows were not checked but should be reviewed for consistency. 2. Two infiltration basins are proposed, and each are designed with an infiltration rate of 0.8 in/hr. Given HSG D soils on site this is not an appropriate infiltration rate and basins are likely to retain water for longer than 48 hours. Further assessment of infiltration feasibility is highly recommended. It is also recommended that basins be designed with drain tile lines and a gate valve. This allows for dewatering of the basin for maintenance and to aid vegetation establishment. 3. No pretreatment has been provided for runoff that is piped to the infiltration basins. This will lead to accumulation of sediment within the basins which is detrimental to infiltration capacity. Storm sewer profiles were not provided so it is unclear if sump manholes are provided prior to storm sewer discharge. 4. Further review of changes to site drainage are warranted. Under existing conditions Wetlands 1 and 2 drain east to Crownline Drive. Under proposed conditions these wetlands will be directed west towards the other onsite wetlands. 5. The proposed project does not meet runoff rate requirements. Total runoff rate from the site increases for both the 2 and 10-year, 24-hour storms. 6. Significant portions of the site (PR2, PR3A, PR5, PR8, PR9, PR10, PR11) are routed directly to existing wetlands with no stormwater management. Further, PR10 appears to include much of the roadway which is directed by storm sewer to infiltration basin 1, not Wetland 1 as routed in the HydroCAD model. Other routing was not checked and warrants further review. 7. Subcatchments PR6 and PR6A are routed to an existing infiltration basin. Has this infiltration basin been reviewed to confirm it has additional capacity for the proposed runoff? 8. Documentation of required NPDES permit has not been provided. Villas at Crest Woods July 9, 2021 Page 10 Rule E – Erosion and Sediment Control 1. Construction sequencing notes have not been provided. These notes should clarify the timing of infiltration basin construction and whether these facilities will be used as temporary sediment basins or protected from construction sediment to allow vegetation to establish. A detail was provided for temporary sediment basins, but basins were not located in the plans. 2. Perimeter control (silt fence) is needed around Wetlands 4 and 7. 3. Has approval been received for proposed land disturbance outside of the site boundary? Rule G – Wetland Alterations 1. Provide documentation regarding the status of WCA approval for proposed wetland impacts. 2. Provide documentation that a wetland replacement plan has been reviewed and approved by the city of Prior Lake. Rule J – Buffer Strips 1. The overall site plan appears to indicate wetland buffers around unfilled wetlands. However, buffer boundaries have not been clearly market. Wetland buffers should be established and maintained a minimum distance of at least 20 feet and 30-ft average from the wetland edge. Buffers should be maintained with healthy native vegetation and documented by signage located at the upland edge of the buffer. 2. The developer will be required to enter into a Development Agreement and provide Conservation Easements to the District over the wetlands and required buffer strips. If proposed revisions to PLSLWD Rules are adopted prior to development, buffer widths may need further adjusted (expanded) based on Wetland Categorization. Phone 952.447.9800 / Fax 952.447.4245 / www.cityofpriorlake.com Memo The Community Development Department has reviewed the Preliminary Plat and PUD plans for the subject project with a plan date of 8-18-21 and we have the following comments. General 1. Development Fees – The following development fees are to be collected prior to recording of any approved 2021 final plat application: Park Dedication of 61 lots at $3,750 per lot, Trunk Water ($3,840/net acre), Trunk Sanitary Sewer ($4,700/net acre), Trunk Storm Sewer ($4,160/net acre), and a 6% administrative fee and 8% construction observation fee based on the total estimated construction costs (which include landscaping, streets, public trails, and public utilities). 2. The City Council will need to weigh the modifications (lot size and setbacks) requested verses the amount of PUD Benefits proposed above standard development requirements. PUD benefits the City Staff believe are being proposed include: · Dedication of land and trail construction of trail leading to Summit Ridge Park (in addition to standard Park Fee payment) · Additional tree plantings in landscape plan – 80 additional trees over required 252 trees 3. Warranty Deeds – Submit draft warranty deeds for any future public ownership Outlots with Final Plat application. Preliminary Plat/Site Plan 4. PUD Zoning Modifications – In addition to other proposed public improvement modifications, the developer requests modifications to the typical R-1 zoning requirements in the following areas: a. Lot size – Min. proposed – 6,065 sq. ft. Min. required (R-1) – 12,000 sq. ft. b. Lot width - Min. proposed – 36 lots at 55 feet, 25 lots at 70 feet Min. required – 86 ft. c. Setbacks – Min. proposed – 7.5 ft side yards Min. required 10 ft. side yard Date: August 30, 2021 To: Bill Stoddard, Stoddard Companies From: Jeff Matzke, Planner Subject: Villas at Crest Woods Rezone, Preliminary Plat, and PUD City Project #DEV21-000008 5. Setback Exceptions - Are any decks, eves, cantilevers, or window well pits proposed within the 10-foot side setbacks, 25-foot front setbacks, or 25-foot rear setbacks? If so, they need to be identified as a note on the preliminary plat plan. Grading Plan 6. Retaining walls – Any walls exceeding 4 feet in height will require a building permit application. Tree Preservation/Landscape Plan 7. Tree placement – On landscape plan/details plan, indicate note that placement of all trees shall be a minimum of 5 feet from front property lines within front yards. 8. Tree replacement – The plans identify a total of 139 caliper inches of tree replacement. Landscape plan indicates 332 trees at 2.5 inches per tree on the landscape plan which will more than satisfy the tree replacement requirement. A minimum of 2 front yard trees and 4 corner trees are required per lot and are indicated on the proposed landscape plan. 9. Final tree locations – Tree locations may be subject to change depending on field construction of public/private utilities and maintenance access locations for ponding and utilities.