Loading...
HomeMy WebLinkAboutPlg Permit 06-0041 ~tJMENT VIEW Page 2 of3 CITY OF PRIOR LAKE PLUMBING PERMIT :- .iJ:.. OC:I. 064-1 :: =- E,i_ r PERMIT Nt> J 1 ~1 zs-. 2-4-rP. (}(J / 0 PID ~O~:;~S+7U'V;~;~LL ~TS. CAST I :;~D::;WN=:: (l) OWNBR. J\A . I I (Name) , '\€.r I ~ \ ~ V\ (Addte8l) 2 '1.- ~~~ Y h?\ ,All M Pc \-.a ~./ (q) / Y\ C f {Phone) -'l L - ~2l--. 3jq q (Addna) i L t.t5...Lkke L~rrf RnI W'/I\6 Lahes (Addrea)' ~ =- <J.~. V~)- "Sf - r.tf:1, -e'l./~ (CoMaCtPrnon) y( e~ Lef1ll{),p'1 p /-1('(J,{)fhCX S (phoDe) G!1~5-22- 5~qq APPLlCANI'SIGNAnJRE .-. DATE ''1- 2 (phone) i:5J - 6 9~ - 21 g- D APPLICANT PLEASE COMPLETE BELOW Quantity of Jb.tllre utity b Bath Tub with or withOUl shower Dishwuber ocr a1n Lavatory (Bathroom Sink) Laundt')l Tray (1 or 2 compartment sink Slwwer Stall Sm s Bar Sink Water C oset (Tol ) J::W; c rl e.- 2J;f) ~ Ci FEE SCHEDULE .~ la4ultTlll. CommercIal"" Mllld-1'4lDily 1% of job COlt with a $39.S0 millimllm RCI!Iidcllti.~ New OIIc a. 'lWo'PlImi V ~ ~ J(O \ Rclideodal, Addftions & AJtentiGn \\\Cf,\o ~v1( A'.", tit t, BMJ1Da~ Cost s r"))o DD. ()O BuUdilJl Permit # ~ ty'. :. \ "S' ~. oJ' ? ,) . ~ ).'>r' \.P ~ ~;tlr '6' PLUMBING PBIlMIT PEE $ J. 3 O.() 0 "~; !L-.?(' "\~} 0\0 1Y' \ tfl)/" tJ~TAmSURCHAROE $ .so ~ . . ''\I '?\'V; w-- ,): \ .,' ><;\)5 TOTALPElDUTllB S-....$i ~ D .c;v . ~A or Il~~1J~~~y).: ~~e. ~(:: ~1_ ~.: _ I. m., . I I _ .. I _ '.' Z Jl'http://64.122.48.40:8080/weblinklDoc View.asp?DocumentID=445&F 0IderID=334&Sear... 12/22/2005 "I..~' ~ ~ r/17/o~ ~U:PR ~ ~ ~O~ WI ENGINEERING INC. By 5430 Douglas Drive North Crystal, MN 55429 763-585-6742 main 763-585-6757 fax Email: steen@steeneng.com April 17, 2006 Mr. Bernie Feidt Prior Lake City Inspector 17073 Adlmann Street Prior Lake, MN 55372 Re: 4680 Tower Street Prior Lake, MN Steen # JHM200601 Dear Bernie, Weare writing this letter in response to your request to determine if new 950,000Btu!hr water heater (that replaced 3 -500,000Btu!hr old water heaters) with 200 gallon tank has an adequate water supply and venting capacity. I've visited the site and spoke to Mr. Jay Crothers with Jay Hawk Mechanical. These are our findings: The hot water capacity is sufficient for 67 apartment building (at 2-1/2 persons per apartment and 2-hr peak load period criteria. The water heater has 14"vent and connected to a common flue with connector rise more than 4ft and very short horizontal length. Existing Type B double wall-common vent diameter is 24" with vent height more than 30 ft. This is (According to Table 504.3(1), Page 82 Minnesota Fuel Gas Code) sufficient to vent 7 natural draft boilers at 375Mbh each, two small pool heaters and 950,000Mbh water heater. There is one Outside Air Opening 56"x36", sleeved thru the wall and ducted down to 12" above finished floor. Part of this opening is taken by 24"x24"separate sleeve with 3,000 cfin capacity mechanical fan at the ceiling level. Designing Sensible Cost Effective Solutions Mr. Bernie Feidt April 17,2006 Steen #JHM200601 Page #2 According to Minnesota Fuel Gas Code, ph.304.3.2: the C.A. opening would need I sq. in per 3,000 Btu/hr. There is no louver, but a !h" by !h" mesh over the face of the opening. Total area of the opening is 1,532sq.in. The mechanical combustion air supply shall provide for: 3,000 Btu/hr x 1,532sq.in =4,596,000 Btu/hr and exceeds the total heat input rating of all the appliances located in the boiler room. If you have any questions or comments, please call. Sincerely, Steen Engineering, Inc. J~clNd~ Igor Melamed, P .E. Principal Associate cc: Maria Gruenwald, Jay Hawk Mechanical Jay Crothers, Jay Hawk Mechanical J6 11:13a Ja~ Crothers From: Mulcahy Co, Inc. To: Jay Hawk Mechanical 6125229492 Page: 212 Date: 3130120069:10:00 AM p.2 .M.llh9~Ij'y Fax Cover Sheet Company: Jay Hawk Mechanical To: Jay Fax#: Date: March 30, 2006 From the Desk of Dave Duncan Direct Phone: 651.256.2427 Fax: 651.686.8588 E-mail: dduncan@mulcahyco.com Page 1 of (including cover sheet): 1 RE; Prior Lake Project, Water heater venting The venting on this project is acceptable and in accordance with the National Fuel Gas Code, NFPA Standard 54, ANSI Z223.1 which contains the following provisions. 7.2 Minimum safe performance 7.2.1 Adequate Draft. The venting is Double Wall B-vent 24" Dia, 50 foot height 3575 M8H input total Mech. Draft of 3000 CFM and a 36 X 20 Louver Regards, Dave Duncan RBI Water Heater Factory Representative 2700 Blue Water Road # 100, Eagan, MN 55121. phone 651.686.8580 . fax 651.686.8588 www.mulcahyco.com ~ . I .c.uuu l Uc. U'l' U'1 r II ;:) J r.r.I'I r.l'llr ll'ltt.l'U Nll r HI( NU. ro:i ~~~ 6757 Apri1 11, 2006 Mr. Bernie Feidt Prior Lake City Inspector Re: 4680 Towt:r Street, Prior LaJcc, Mn Steen # Dear Bernie, We are writing this letter in response to your request to determine if new 950,OOOBtuIhr water heater (that replaced 3 -SOO,OOOBlu/hr o1d water heaters) with 200 gallon tank has an adequate water supply and venting capacity. I've visited the site and spoke to Mr. Jay Crothers with Jay Hawk Mechanical. These are our findings: The bot water capacity is sufficient for 67 apartment building (at 2-112 persons per apartment and 2-hr peak load period criteria. The water heater has l4"vent and connected to a common flue with connector rise more than 4ft and very short horizonta11ength. Existing Type B double wall-common vent diameter is 24" with vent height more than 30 ft. This is (According to Table 504.3(1), Page 82 Minnesota Fuel Gas Code) suffiCient to vent 7 natura\ draft boilers at 375Mbh each, two small pool heaters and 950.000Mbh water heater. If you bave any questions or comments. please call Ph.#763-58S-674Z Sincerely, STeen Engineering, Inc. Igor Melamed, P.E. Principal Associate, Mechanical p,2 p, 02/02 CITY OF PRIOR LAKE INSPECTION NOTICE ADDRESS 7/bJ'O OWNER SCHEDULED /b'l--c,.; -e , . CONTR. TIME PHONE NO. PERMIT NO. 6Cf ~oo4-C- o FOOTING o FOUNDATION o FRAMING o INSULATION o FINAL o SITE INSPECTION COMMENTS/, A/~1iV , o PLUMBING RI o MECH RI o WATER HOOKUP t:;I ~R HOOKUP $PLUMBING FINAL o MECH FINAL .2cJo c;: ;:' o EXIGRADIFILLlNG o COMPLAINT o FIREPLACE RI o FIREPLACE FINAL o GASLlNE AIR TST o l-<//# ;f:ce<l.-ed ~~hU--~4d// ~ /' / . /4/' OK , ~K SATISFACTORY. PROCEED o CORRECT ACTION AND PROCEED o CORRECT~ RElNSPECTION BEFORE COVERING Inspector: Owner/Contr: CALL 447-9850 FOR THE NEXT INSPECTION 24 HOURS IN ADVANCE. CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH & SAFETY! .NS/IOTl