AGREEMENT AND REPORT OF INSPECTION
#INSPECTION "Z ( , ? Z ~
REPORT TO
STREET
CITY & STATE
,{ ....'~- \
J,
L
~... v".~.,
BUILDING OR LOCA nON
INSPECTOR
DATE
>_ I \ ',..' ! ~-t I.
~r.v\ /\ (
il.
'.j:..) ~'.J~.J! i," !, C...
i. -, {,_, ; '~: ~!
b '\'.)( ...:., L
<-'\<4~_
L ~
jt
. .
Owner hires Viking Automatic Sprinkler Company to conduct an inspection of the fire suppression system at the above location or building, and
prepare a written report of that inspection for an agreed upon fee. As part of this agreement, owner agrees to terms and conditions on rear of form and
will complete the Owner's Section of this document.
Owner's Section (To be answered by Owner or Occupant)
A. Explain any (X'cupancy hazard changes since the previous inspection: /' 'c..' "
B. Describe fire protection modifications made since last inspection:
,'. .. ,/ .1'.
C. Describe any fires since last inspection:
A........., '.... If .../ (.
D. When was the system piping last checked for stoppage, corrosion or foreign material?
E. When was the dry-piping system last checked for proper pitch?
F. Are dry valves adequately protected from freezing?
Ii! "
f- f i.
.C'.-
.!/,. r~'~
Signature =--- Title Date d - ;)(J -C) I
Inspector's Section (All responses re N/A = NOT APPLICABLE
1 General
a. Is the building occupied? ~es uNo
b. Are all systems in service? J7Yes 0 No
c. Does there appear to be a minimum of 18 in. (457 mm) clearance between the top of the storage and the sprinkler deflectors? J;lXes n No
d. Does the valve hose on the sprinkler system(s) appear to be satisfactory? u Yes uNo Q-N/ A
2 Control Valves (See Item 15)
a. Do sprinkler system control valves appear to be in the appropriate open or closed position? l4"i'es 0 No
b. Are control valves in the open position locked, sealed or equipped with a tamper switch? ~es uNo
3 Water Supplies (See Item 16)
a. Was a water flow test of main drain made at the sprinkler riser(s)? D"'fes 0 No
4 Tanks, Pumps, Fire Department Connections
a. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? 0 Yes 0 No B"NI A
b. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight? )~s 0 No LJ. N/ A
Are they accessible and visible? ~s 0 No 0 N/ A
5 Wet Systems
a. Are cold weather valves (0.5. & Y.) in the appropriate open or closed position? u Yes 0 No ,~/ A
b. Have antifreeze system solutions been tested? [J Yes 0 No ~/ A
c. Were the antifreeze test results satisfactory? 0 Yes 0 No ifNI A
d. In areas protected by wet system(s), does the building appear to be properly heated in all areas, including blind attics and perimeter areas
where accessible? ;/Y'es 0 No 0 N/ A Do all exterior openings appear to be protected against freezing? DXes L1 No 0 N/ A
6 Dry System (See Items 11 to 13) /
a:l\re.dryvalves (s) in service? 0 Yes 0 No 0 N/ A
b. Are the arr~es and priming water levels in accordance with the manufacture's instructions? L1 Yes D No n N/ A
c. Has the operation o~gen supplies been tested? 0 Yes 0 No 0 N/ A Are they in service? n Yes 0 No 0 NI A
d. Were all know low points drained ~ inspection? 0 Yes 0 No 0 N/ A
e. Did quick-opening devices operate satisfact~D Yes 0 No [J N/ A
f. Did the dry valve(s) trip properly during the trip pressure test? l; Yes uNo 0 N/ A
g. Did the heating equipment in the dry-pipe valve room(s) operate at time of inspection? 0 Yes 0 No n N/ A
7 Special Systems (See Item 14)
a. Diall're-~~ction valves operate properly during testing? II Yes n No n NI A
b. Did the heat-responsivea~operly during testing? 0 Yes 0 No D N/ A
c. Did supervisory devices operate during teStm~__D No 0 N/ A
8 Alarms
a. Did water motor(s) and gong(s) test satisfactorily? [] Yes [J No g,Xf A
b. Did electric alarm(s) test satisfactory? oX"es 0 No . 0 N/ A
c. Did supervisory alarm service test satisfactory? ~s 0 No u N/ A
9 Sprinklers
a. Do visible sprinklers appear to be free from corrosion, loading or obstruction to spray discharge? [K"f'es 0 No
b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) r;vYes 0 No
c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testing) 0 Yes 0 No ~I A
d. Is stock of spare sprinklers available? p.-Yes 0 No
e. Does the exterior condition of sprinkler system appear to be satisfactory? ,.,ryes 0 No
f. Do visible sprinklers appear to be of proper temperature rating for their locations? ~Yes 0 No
10 Explain any "No" answers and comments:
,t.
Signature:
(Rev. 2/8/(6)
\. 1-,,_"1 .~~,__",-..// ;,-. .J
I. '__
Date:
". ..t. ... C3i
AUTOMATIC SPRINKLER CO.
Setting The Standard...
1301 L'Orient Street
St. Paul, Minnesota 55117
(651) 558-3300 . (800) 229-6263
Fax: (651) 558-3310
SHEET 2 of 2 - Use separate sheet for each system inspected
System No. or Description if multiple
systems
Inspection Report
No. .'-' > ,"
11 Date dry-pipe valve trip tested (control valve partially open)
12 Date dIX~pipe valve trip tested (control valve fully open)
13 Date quick::'ope}u~g device tested
(See Trip Test Table which follows)
(See Trip Test Table which follows)
(See Trip Test Table which follows)
DRY PIPE
OPERATING
TEST
DRY->,I.Al, VE TRIP TEST TABLE O.O.D.
MAKE '. ---.-, MODEL SERIAL NO. MAKE MODEL SERIAL NO.
......--.,."
-" ~
~-
Time to Trip Water " Air Trip Point Time Water Reached Alarm Operated
.- -- "
Thru Test Pipe Pressure Pressure - Air Pressure Test Outlet Properly
MIN. SEe. PSI PSI ~- l'S1 MIN. SEe. YES NO
Without .~'... ........, ~~.
Q.0.D -'.
With ~
Q.O.iJ -,
14 Date deluge or preaction v~tested
------
(See Tnp Test Table whIch follows)
TRIP TEST TABLE
DELUGE &
PREACTION
V ALVES
Operation D PNEUMATIC '"""--- o ELECIRlC D HYDRAULIC
Piping Supervised DYES ---- o NO I Detecting Media Supervised DYES D NO
Does valve operate from the manual trip andl or remote~ol stations DYES o NO
Is there an accessible facility in each circuit for testing ""..... 0 YES o NO IMethod of Testing Circuits
~~irCuit operate Does each circuit Maximum time to
MAKE MODEL SUpervisltlt\..l,OSS alarm operate valve release operate release
YES I -'NO YES I NO YE~ I NU
I I I
15 See Control Valve Maintenance Table
CONTROL VALVE MAINTENANCE TABLE
Explain
Abnormal
Control Valves Number Type Open Secured Closed Signs Condition
City Control Valves I 1'- t / , T ~.,..-
,.
Bypass Valves
Tank Control Valves
Pump Control Valves
Sectional Control Valves
System Control Valves
Other Control Valves i t...,..-"! .. po,.", 1;.--, i ~ ,',; ~ I . --
Kitchen Control Valves ."-+ , -(. 1
16 Water Flow Test at Sprinkler Riser ylS \
Water Su I Source: / I? t
Tank
.. ~
-Z Ii'.
Test Pipe
Location
Static
Pressure
Pum
Residual
(Flow)
Pressure
Date
Last Water Flow Test
This Water Flow Test
..,
17 Explain any "No" answers and comments:
18 Adjusbnents or corrections made during this inspection:
19 Although these comments are not the result of an engineering review, the following desirable improvements are recommended:
Signature: \~) C
(tJ
'~
( )
'-
Date: .2 (( ) (j~;
(Rev. 2/8/06)