HomeMy WebLinkAboutFire Alarm 3/19/2007 FIRE ALARM INSPECTION AND TEST REPORT METRO ALARM "WE SAVE LIVES & PROTECT PROPERTY" METRO ALARM CONTRACTORS, INC P.O. BOX 1775 BURNSVILLE, MN 55337 SERVICE (952) 890-6684 FAX (952) 707-6881 LIC#CCOI031 I COpy TO: ACCT. NO 4 5/- 13 J '1r SERVICE CALL NO. 4/ 03 7 U.L CERTIFICATE NO. CUSTOMER py,'(Jr La,/(f1 lIAnI"'l-t:Lhr~ Len I-p.r CONTACT ("/lia Eld.rI~d ADDRESS /7073 Adp'II/hf)V'J~ Sf SE PHONE'152-"l.flI7-Qft(1 CITY Pr/nr Lake STATE }1I11 I ZIP S S.37 2. CONTROL PANEL , MANUFACTURE ~,le'l f Y.. ,;../"I MODEL NO. !) Z 07 TYPE OF SIGNALING v ~ENERALALARM _SELECTIVE SIGNALS _CODED _PRE.SIGNAL BATIERIES VOLT WITH CHARGER_ I, .r.roTi # VOLT WITHOUT CHAR&ilIi\. ..., kt'J f .NEW CLIENT FIRE DEPT. I DATE '7?//Q h7 7 I TITLE I_Bl.MONTHLY _,SEMI.ANNUAL MONTHLY ~NNUAL I ~QUARTERLY _FINAL COMMUNICATOR MANUFACTURE 5 A M E ~ODEL NO. BATIERIES VOLT WITH CHA~R NOTE # VOLT WITHOUT CHARGER LOCATION Flee frtC--fL I rJ'ln,..,., POWER fIR BRKR LOCATION Nq.,.. LOCKED CIR BRKR DEDICATED CIR SOURCE f"),1-1 h _YES ~O AYES _NO TROUBLE RESPONSE TO ZONE TROUBLE SIGNAL TROUBLE AC/OP POWER LOSS EARTH GROUND CONDITIONS )>NORMAL NOTE pORMAL NOTE ~ORMAL NOTE NORMAL NOTE NEW LOCATION 4A MEA POWER CIR. BRKR. LOjt!.TIbN NO. LOCKED CIR BRKR. DEDICATED CIR SOURCE / YES NO YES NO TROUBLE RESPONSE TO ZONE TROUBLE SIGNAL TROUBLE AC/OP POWER LOSS EARTH GROUND CONDITIONS ~ORMAL _NOTE ~ORMAL _NOTE ~ORMAL _NOTE _NORMAL _NOTE CENTRAL MONITORING STATION RESPONSE TO ALARM ~ORM. _NOTE # COMMUNICATORPRIMARY# QS2-lfl(O... q6 7g AUXILIARY FUNCTIONS ANNUNCIATQf (MFG) y . J.f I MODEL S TYPE _IN CAD S,/enl ^-f)/Q h 230 _LED ELEVATOR RECALL TO PRIMARY FLOOR RECALL TO ALTERNATE FLOOR FIRE RECALL _NORMAL _NOTE XfI/A _NORMAL _NOTE Xl'l/A COMMUNICATOR SECONDARY # 95 "2 ,-l{ l{ 0.. l{ bb 0 _GRAPHIC _DROP _CRT I VOLTAGE ;... INO OF ~NES /UNUSIi9 PTS. XLCDI 2 V vJj (, 1 .., ELEVATOR RESTART FROM FIRE SUe. AUTOMATICALLY _YES _NO SPRINKLER SYSTEM: METRO ALARM'S INSPECTION ONLY INCLUDES A FUNCTIONAL TEST. ACTUAL FIRE SPRINKLER TEST WAS DONE BY: Na 1/011 q, { 5 or J n klf7r PERIPHERAL FUNCTION TEST DEVICE 'AI OCt7 FLOOR Manual Stations TESTED: 1/1/ i7 , VOLTS MFG & MODEL # NOTE R of R Heat Detectors Fixed Heat Detectors Photo Smoke Ion Smoke Duct Smoke Z I I 7. Vo/Dr: 5'V:!>Ie,." 5e"sr;'.-- m Po1/er Sv&, fehf 5t?~ Waterflow GVT PIV Low Air Horns Only Strobes Only S /2 I 2'-1vD (. Sth-,plev 21r1l1f:, ::5/"'#~o~/a:// ~ Horn / Strobes Speaker / Strobes Door Holders NOTATIONS AND COMMENTS #( .AL ..,,, c-eikna in 1>.&__....... locKer Ynon, / . /I II Te:~/4 hood CUSTOMER SIGNATURE: #' _ A' SERVICE REP SIGNATU~P'....?' A7' L-:;#-- u:::::.. -/L- ~/~ ~/Z, 7~ "