Loading...
HomeMy WebLinkAboutFire Sprinkler Report - 1/28/11 Form 6 �' Autamatic Sprinkler Systems Inspection, Testing, and Maintenance of Wet Pipe Sprinkler Systems Property Name: Park NiC011et Clinic Inspector: Dan Feiner Property Address: 16705 Franklin Trail East Prior Lake, MN 55372 Contract No.: 88186 Phone Number: (952) 993-5000 Date: 1/28/2011 This Report Covers: ❑ Monthly ❑ Quarterly ❑ Annual ❑ Three-Year � Five-Year Inspections Ma�n'thly ❑ Yes ❑ No � N/A Gauges—normal water pressure maintained Control Valves ❑ Yes ❑ No � N/A In the correct (open or closed) position ❑ Yes ❑ No � N/A Sealed, locked, or supervised ❑ Yes ❑ No � N/A Accessible ❑ Yes ❑ No � N/A Free from damage or leaks ❑ Yes ❑ No � N/A Proper signage Alarm Valves ❑ Yes ❑ No � N/A Free of damage ❑ Yes ❑ No � N/A Accessible ❑ Yes ❑ No � N/A Retard chamber/alarm drains not leaking Quarterly ❑ Yes ❑ No � N/A Alarm devices—free of damage ❑ Yes ❑ No � N/A Hydraulic data nameplat�securely attached to riser/legible Fire Department Connections ❑ Yes ❑ No � N/A Visible and accessible ❑ Yes ❑ No � N/A Coupling/swivels operate correctly ❑ Yes ❑ No � N/A Plugs/caps aze in place ❑ Yes ❑ No � N/A Gaskets are not damaged ❑ Yes ❑ No � N/A Identification signs are in place ❑ Yes ❑ No � N/A Ball drip valve is functional Pressure Reducing Valve ❑ Yes ❑ No � N/A In the open position/not lealcing ❑ Yes ❑ No � N/A Maintaining downstream pressure �FP�° NFPA Water-Based Fire Protection Systems Forms 1 of 3 Form 6 ❑ Yes ❑ No � N/A In good condition Annual Sprinklers (visible) ❑ Yes ❑ No � N/A No damage or leaks ❑ Yes ❑ No � N/A Free of corrosion, foreign material, or paint ❑ Yes ❑ No � N/A Installed in proper orientation ❑ Yes ❑ No � N/A Fluid in glass bulbs ❑ Yes ❑ No � N/A Spaze sprinklers—proper number and type. Complete witt► wrench? ❑ Yes ❑ No � N/A Hangers and seismic bracing—not damaged or loose Pipes and Fittings (visible) ❑ Yes ❑ No � N/A In good condition/no external corrosion ❑ Yes ❑ No � N/A No leaks or mechanical damage ❑ Yes ❑ No � N/A Correct alignment no external loads ❑ Yes ❑ No � N/A Hose racks�inspected per NFPA 1962 ❑ Yes ❑ No � N/A Building—wet piping not exposed to freezing temperatures Five-Year � Yes ❑ No ❑ N/A Alarm valve interior including strainers, filters, and restriction orifice � Yes ❑ No ❑ N/A Check valve—internal moves freely, in good condition � Yes ❑ No ❑ N/A Obstruction inspection—no foreign or obstructing material found Test Quarterly ❑ Yes ❑ No � N/A Alarm devices—water motor gong ❑ Yes ❑ No � N!A Main drain test if the sole supply is through a backflow preventer Static psi Residual psi ❑ Yes ❑ No � N/A Do results differ by more than 10% from previous test? Semi ❑ Yes ❑ No � N/A Supervisory switch functions ❑ Yes ❑ No � N/A Alarm devices—inspectors test or bypass opened/obstructed watertlow Annual � Yes [� No � N/A Main drain test Static Residual ❑ Yes ❑ No � N/A Do results differ by more than 10% from previous test? ❑ Yes ❑ No � N/A All control valves operated through full range of motion and returned to normal position. ❑ Yes ❑ No � N/A Specific gravity or anti-freeze system (if present) ❑ Yes ❑ No � N/A Backflow preventer test ❑ Yes ❑ No � N/A Backflow preventer—flow test H"�w► NFPA Water-Based Fire Protection Systems Forms 2 of 3 Form 6 , Three-Year ❑ Yes ❑ No � N/A Hose has been tested in accordance with NFPA 1962 Five-Year � Yes ❑ No ❑ N/A Gauges tested or replaced I � Yes ❑ No ❑ N/A Pressure reducing valv�flow test and to previous results Routlne Maintenance I ❑ Yes ❑ No � N/A Sprinklers tested or replaced per appro�riate testing schedule Comments ' All internal inspection areas look good. There are no obstructiorls. signature: Dan Feiner Date: 1/28/2011 License/Certification No.: ] 11 ra°�Ra NFPA Water-Based Fire Protection Systems Forms 3 of 3