HomeMy WebLinkAboutElevator Approved for Use ic-s, (_/t-' Z.> d ` )%\ I 4 I 0 SO ' Department of Administration January 14,2004 APPROVED FOR USE Keystone Communities of Prior 5200 Wilson Rd., Ste. 150 , Edina MN 55424 RE: Hydraulic Passenger - Elevator ID# -09436PT03-01 Site: Keystone of Prior Lake, #2 4685 Park Nicollet Ave. Prior Lake 55372 Dear Sir/Madam: Minnesota Statutes Chapter 16B provides that the Department of Administration, Building Codes and Standards Division, Elevator Safety Section, inspect and approve elevators and manlifts (endless belt lifts) before they can be legally used in Minnesota. An Inspector from the Elevator Safety Section recently inspected your facility and determined it meets requirements of the Minnesota Elevator Safety Code. NOTE: Compliance with Minnesota Rules and the ANSI/ASME A17.1, Safety Code for Elevators and Escalators does not necessarily assure compliance with the Americans With Disabilities Act of 1990. Sincerely, BUILDING CODES AND STANDARDS Bill J. Reinke State Elevator Inspector bjr/kad (CE-2) C. Hutchins, Robert Dana, BO, City of Prior Lake Schindler Elevator Corp. Weis Builders ElFormCE2 Building Codes and Standards Division,408 Metro Square Building, 121 7th Place East,St.Paul,MN 55101-2181 II Voice:651.296.4639,Fax: 651.297.1973;TTY: 1.800.627.3529 and ask for 296.9929 r0\ 01.4A7 1.L/VL0 is... 1L// I r . WL/WW WI I I • . nv,-L , vL•vT • r Niwr SODepartment of Administration ARE YOU READY • FOR AN ELEVATOR INSPECTION? The following Items are most often incomplete: 1. Is two-way communication provided and working? Is there call-in and call-cut capability? Does it include emergency operating instructions with elevator telephone number? (A.D.A. compliance is required.) 2. Are the smoke detectors installed at each lobby and in the elevator machine room? And, are the lobby detectors zoned? There is to be no built-in time delay. Verification is not permitted or allowed. 3. Will the smoke detector installer be at the inspection to conduct the required test for the elevator inspector? Have Phase I and II been tested to assure proper operation? 4. Has all equipment and appurtenances not directly related to the use,function, or operation of the elevator been removed from the machine room arid hoistway? (such as non-related ducts, piping, conduits, and equipment) • 5. Have you provided and installed a wall-mounted fire extinguisher In the machine room located by the door? 6. Have you provided a machine room door closer and self-locking lockset? (Door must be normally openable from inside machine room). 7. Does your machine room lighting provide 10 foot candles of fluorescent Illumination at floor level? 8. is your machine room door assembly properly fire rated, smoke sealed, and labeled? 9. is your machine room the same fire rating as your hoistway? 10. Have you provided a hoistway vent (3.5% of hoistway or 3 Sq. Ft. minimum, per elevator)? Venting required for elevators having a travel of 25 feet or more. Building Codes and Standards Division, 408 Metro Square Building, 121. 7th Place East, St. Paul, MN 55101-2181 Voice: 651.296.4639; Fax: 651.297.1973;TTY: 1.800.627.3529 and ask for 296.9929 4