HomeMy WebLinkAboutFire/Smoke Silicon Seal 1 nr IMPORTANT /41
Compression Bulb
A POSITIVE PRESSURE LABEL OR UBC 7-2 UL10C 1/4" (::: Stabilizer
, riuM KO COMPLIANCE IS STAPLED TO E RED WARNING (s.4) /Flange
SHEET. DO NOT LOSE IT! YOUMUST AFFIX THIS (6.4 mm) + Adhesive
SUPERIOR DOOR ,� 1/2" -.I Backing
EDGE SEALING SYSTEM LABEL TO THE HINGE JAMB @48"ABOVE FINISHED High (12 7)
FLOOR NEXT TO THIS SEAL FOR FIRE INSPECTION. Shown at 112%of actual size
BLACK
0 S88BL17 :c:11161:7325112-5
7'Long(5,82a3a ww +�ust7• 9.! ,t� �r�s , 4
UPC 0-86787 59351 5 ; , ,
❑ S88BL20 UP On88768729801 a { m. { : 1� ,a
❑ S88BL21 21'long(6401 mm) ; F i
QQ UPC:0-86787 40481-1 � 6 ` I ,, , t ,'
❑ S88BL25 25'Lang(7520 mm) 11„,',7,; ;: ax .. s ,°"} a ' t:,r,
UPC:0-86787 89811301'1.2.
30'Long(9144 mm) n;;� � ,:=a � , E : : ,- �# $y r 1 1 i''
El S88BL30 uPc:o-es797509a1a � -4 ,s4 ,,`,,, ' , .
CLEAR ., DOOR ` .i "s 1 ,
17,Long 162 mm � i zt ups -� � " i P i iiii'' {,'' ' P Sno's u& hl�" wtP r� `'v'' '; `�
❑ S88C17 g ) ff ,, ,, ,,
UPC:0-86787 93991-7 �' `� � "�^ � �`��- � ,�"
❑ S88C20 UPC 0-867687 43791-8
❑ S88C21 UP , ;� Tested & Listed For Fire & Smoke
❑ S88C25 25'Lang(7820 mm)
a7 �I �! UPC:0-86767 2596,-9 ■ ■ T M
0 S88C30 UPC 0-867877271-4
DARK BRONZE
,TLong
(5882mm) Door. Edge dealing System
conSeal
S88 D 1 7 UPC 0-86787 02003-5
888D, 20'Lodg 787 632 i
f , ilk;0-6787 98323-3
❑ S BFT,21,4„100401.0 Use On Door Framesl
Qp 1um in' m"mi 1 To Seal Top & Sides of Door <1� -
❑ S'80025(UPO:0-88787 67758-1
❑ S88D30 :;:c:1-71:4427,71.3 Use With HSS2000 (When Required),
TAN Pemko's Intumescent Edge Sealing System
Many UL1OB doors can be listed for UL10C&UBC 7-2,Part 1 •
❑ S88TAN 17UPCLong(518279123 mm)-2 by adding HSS2000.Consult your wood/steel door manufacturer. i
:0 86787
❑ S88TAN20 20'Long(6096 mm) ��psslFjFo ;
a i Compression Bulb Instructions:
Use On. Use With.
1/4" Stabilizer 1. Remove approximately 24
Door Frames HSS2000 (when Required) Is.4, �Flange (610 mm)of backing from the
To Seal Top & Pemko's Intumescent 588 1 " Backing SiliconSealT"' strip.Be careful
Sides of Door Edge Sealing System (�?) not to touch s wild dirty or
sweaty hands or drag the
adhesive on the ground.
IMPORTANT:Read before installation!Failure to do so may void 2. With the stabilizer flange
guarantee or result in im ro er adhesion. pointing away from the stop,
p p position the SiliconSealT"" as
1.Application laments= If frames are too cold(below 50°F)or too hot(above 100°F)adhesion may be impaired.Attempt illustrated to the Aft.Without
to elevate ambient temperature.Do NOT heat gaskets. stretching It,pn�ss down
each inch of length to activate
2. When lb Install: Installation of S88 should take place after construction is completed,flooring installed and final cleaning all of the adhesive against the
complete.
frame.The use of a hand roller
3.Paint must he cared forat teast5-7days. Paint cannot be wet under drysurface when gaskets are pressed on.Avoid is highly recommended.
quick-dry primers,which leave powdery surface,preventing sufficient adhesion.When applying S88 to a wood frame 3. RemOVe the neX1 24�� 610
or door,the surface must be non-porous,sealed,painted or varnished.Follow standard industry guideline on sealed wood (
frames and abrade or rough surface before applying.Note:Anti-bacterial,anti-fungal or silicone additives in paint mm)of paper baking and
may inhibit adhesion. repeat(Z.) until the entire
4.Sar/sce Areparation: Use enclosed cleansing towelette to remove grease,dust or cleanser build-up.Some hospital length for a top or side is
environments have wax or anti-bacterial cleanser build-up.As an alternative or substitute cleanser,use isopropyl installed.Do not install as one
(rubbing)alcohol.Note:Mineral spirits or other petroleum cleaning products should NOT be used. Continuous piece-cut the I��
5.Application and Wan,h,gs (A)Don't stretch material.Product can retract or shrink if stretched.(B)Use veryfirm, Silicon$eal TM (With a A
perpendicular pressure when applying.Extra pressure required due to product weight and absence of re compression cope or miter joint)at/
(C)Use wallpaper seam roller or screwdriver handle butt to reinforce adhesion after applying.Caution:do not stretch the Corners where'the
material when using reinforcing roller or screwdriver butt.Run roller or butt with up and down motions.(D)Double check
adhesion after 2-3 hours before leaving job overnight.(E)If smoke gasket or intumescent strip separates from frame top and sides meet.
press again with firm pressure in place.If adhesive strip is exposed,airborne dust may impede adhesion.Replacement
may be necessaryat this stage.(F)Note:Headers must be installed with equal pressure as jambs.Sometimes too
little pressure is applied at header due to awkward overhead application.
6.Far piggybeckfiasNonsof PK55,PK33,S8 por Sk44,mounted atop HSsS2000,make sure HSS is applied with PEMKO
sufficient pressure first before applying smoke gasket.Wipe down HSS surface if needed,close doors overnight
to ensure good set.
7.NsBx Adrresbn fakes delayed set Immediate remora)and resetting can be done if error occurs in initial replacement.
DO NOT reset after .one hour.Full set is reached in 24 hours. P.O.Box 3780
Ventura,CA 93006
S88 on Frame with Beveled Edge Door Ph:
On beveled edges, install S88(&HSS2000,when required) Fax:(8(80000)228833-9-45:580
on jamb at position shown below. �.r
12251hittierE.,CA Coast D906Dr1.
_ire"-5/32' ; W
(32) (4.0) ' For tighter gaps, °_$ �,
use Pemko's 544, � ,9 b Ph: (800)283-95'88
StO p SiiiconSealT"'. .
ra Fax: (800)283-4.050
_< 588 mounted a �
directly on top ' P.O.Box 18966
of HSS2000.
� Memphis,TN 38181
door face Ph: (800)824-3d 18
net li. ,' Fax (800)243--3656
E , - '.
ea 0I Top View , �I�� www.pemko.com
(Closed Door F T ;.'ill pemkosales@pemko.c:om •
� ` , 9 02mko Mfg Co. Label-588
$ Top View �.� ,:
(Open Door) 3/32".1�� � r
(2.4) 13.2) ) .,a Made in the U.S.A.