HomeMy WebLinkAboutFire System Inspection . "..' , .,.,. ,... ~. "' ~ '. ,"".... Kitchen Hood Fire System InspectiOn & Maintenance Report 'oS ANNUAL INSTALLATION LOCATION OF SYSTEM CYLINDERS Ld ~ 0.(' I-Iooc-I Your Life Safety Specialists 4445 w. nth Sl., Suite 125, Minneapolis. MN 55435 (952) 893.0905 WET DRY CHEMIcAL x CYLINDER SIZE SLAVE FUSE LINKS 4500 F FUSE LINKS 5000 F OTHER Name V(ys-lot'11L of ~'L>"( /..o./ie- Address4CoP6 ;).,,<1[ ~104 Ave'- cityDnD'("" LcJ(~ I MrJ .:57672 TelePhone('iS;))22Lo - 9 ZCCJ Store No. Mo.,V'...... I (f ~r ~a..'<{r~T~,"" COOKING APPLIANCE LOCATIONS & SIZES: LEFT TO RIGHT :rYyrc 16<',11 I ""r':~r~" 1<l~"C .3 FUEL SHUT-OFF ELECTRIC I GAS SIZE (! ~( LAST HYDRO TEST DATE LAST RECHARGE DATE SERIAL NUMBER -::>-003/'/7 03 MANUFACTURER'S MANUAL REFERENCE NOTE: NON COMPLIANT 'Y'T~MS MAY FAIL TO &X1'INGUISHI SUPPRI!SI A FIRE. lli l'lQ W.II lli l'lQ l!IlA 1. System interlocked w~h building fire alarm PI' 0 0 20. Check travel of cable nuts! 8-hooks 0 0 9i' '. "~: gfeCk~~~~v~~correctng~"".~~ g~,~~: ~~n~~cr fIlIme-----7g g~-- 4. System installed per UL 300 standard & meets 23. Proper clearance-flame to fi~ers ;If 0 0 manufacturers U,L listing & N.F.PA standards 9f 0 0 24, Exhaust fan in operating order p 0 0 5. Hood/duct penetrations sealed w~h weld or UL device f!. 0 0 25. All fi~ers replaced P' 0 0 6. Check if seals intact, evidence of tampering "9f 0 0 26. Fuel shut-off in on position J2f 0 0 7. ~ system has been discharged, report same 0 flJ 0 27. Manual & remote set/seals in place E'. 0 0 8. Pressure gauge in proper range (If gauged) 0 0 f? 28. Replace systems covers 2' 0 0 9. Check cartridge weight (If applicable) P' 0 0 29. System operational & seals in place 2 0 0 10. Dry system 6 y_ maintenance date! wet system 12 30. Slave system operational 0 o;!f year hydro-test date % 0 0 31. Clean cylinder & mount ~ 0 0 11. Inspect cylinder and mount P' 0 0 32. Fan warning sign on hood 17 0 0 12. Operate system from tarminallink ~ Q L! 33. Proper signage and personnel instructed in manual 13. Test for, proper operation from remote J7 0 0 operation of system p: 0 0 14. Check operation of micro switch ;!J 0 0 34. Proper hand portable extinguishers 9f 0 0 15. Check operation of gas valve j!J 0 0 35. K class fire extinguisher in cooking area pf 0 0 16. Clean nozzles fi!! 0 0 36. Portable extinguishers properly serviced ';I 0 0 17. Proper nozzle covers in place ;If 0 0 37. Service & Certification tag on system 91 0 0 18. Check fuse links and clean jlJ 0 0 38. Safety chains on all gas appliances attached and secured j;;r' 0 0 19. Replaced fuse links Jlf 0 0 NOTE DISCREPANCIES OR DEFICINCIES BELOW 0 0 0 , COMMENTS: On this date, the a ve system was tested and inspected in accordance with procedures of the presently adopted editions of NFPA 17, 1 an the manufacturer's manual and was operated according to these procedures with results indiclJled above. x ~ SERVICE TECHNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOME U ED AGENT The above SetVice technician certifles that the system was personally inspected and found conditions to be as indicated on this report. WHITE - CUSTOMER . YELLOW - DISTRIBUTOR . PINK - AUTHORITY HAVING JURISDICTION